Skip to Content

9,781 Results Found

  • Article
  • Open Access
16 Citations
6,992 Views
15 Pages

24 April 2020

Grid-connected systems often consist of several feedback-controlled power-electronics converters that are connected in parallel. Consequently, a number of stability issues arise due to interactions among multiple converter subsystems. Recent studies...

(This article belongs to the Special Issue Power Electronics in Renewable Energy Systems Ⅱ)
  • Article
  • Open Access
5 Citations
5,283 Views
11 Pages

Impedance Study of Dopamine Effects after Application on 2D and 3D Neuroblastoma Cell Cultures Developed on a 3D-Printed Well

  • Georgia Paivana,
  • Theofylaktos Apostolou,
  • Sophie Mavrikou,
  • Dimitris Barmpakos and ,
  • Grigoris Kaltsas and
  • Spyridon Kintzios
  • + 1 author+ 0 author

In this work, the assessment of the interactions of a bioactive substance applied to immobilized cells in either a two-dimensional (2D) or three-dimensional (3D) arrangement mimicking in vivo tissue conditions is presented. In particular, dopamine (D...

  • Article
  • Open Access
43 Citations
11,262 Views
19 Pages

Impact of Relaxation Time on Electrochemical Impedance Spectroscopy Characterization of the Most Common Lithium Battery Technologies—Experimental Study and Chemistry-Neutral Modeling

  • Md Sazzad Hosen,
  • Rahul Gopalakrishnan,
  • Theodoros Kalogiannis,
  • Joris Jaguemont and ,
  • Joeri Van Mierlo and
  • Maitane Berecibar
  • + 1 author+ 0 author

In electrified vehicle applications, understanding the battery characteristics is of great importance as it is the state-of-art principal energy source. The key battery parameters can be identified by one of the robust and nondestructive characteriza...

(This article belongs to the Special Issue Feature Papers in World Electric Vehicle Journal in 2021)
  • Article
  • Open Access
57 Citations
6,107 Views
17 Pages

22 October 2016

In the electromechanical impedance (EMI) method, the PZT patch performs the functions of both sensor and exciter. Due to the high frequency actuation and non-model based characteristics, the EMI method can be utilized to detect incipient structural d...

(This article belongs to the Section Physical Sensors)
  • Article
  • Open Access
60 Citations
5,896 Views
17 Pages

Impedance, Electrical Equivalent Circuit (EEC) Modeling, Structural (FTIR and XRD), Dielectric, and Electric Modulus Study of MC-Based Ion-Conducting Solid Polymer Electrolytes

  • Balen K. Faris,
  • Ary A. Hassan,
  • Shujahadeen B. Aziz,
  • Mohamad A. Brza and ,
  • Aziz M. Abdullah,
  • Ari A. Abdalrahman,
  • Ola A. Abu Ali and
  • Dalia I. Saleh
  • + 3 authors+ 0 author

27 December 2021

The polymer electrolyte system of methylcellulose (MC) doped with various sodium bromide (NaBr) salt concentrations is prepared in this study using the solution cast technique. FTIR and XRD were used to identify the structural changes in solid films....

(This article belongs to the Section Polymeric Materials)
  • Article
  • Open Access
59 Citations
4,777 Views
20 Pages

A Study of Methylcellulose Based Polymer Electrolyte Impregnated with Potassium Ion Conducting Carrier: Impedance, EEC Modeling, FTIR, Dielectric, and Device Characteristics

  • Muaffaq M. Nofal,
  • Jihad M. Hadi,
  • Shujahadeen B. Aziz,
  • Mohamad A. Brza and ,
  • Ahmad S. F. M. Asnawi,
  • Elham M. A. Dannoun,
  • Aziz M. Abdullah and
  • Mohd F. Z. Kadir
  • + 3 authors+ 0 author

26 August 2021

In this research, a biopolymer-based electrolyte system involving methylcellulose (MC) as a host polymeric material and potassium iodide (KI) salt as the ionic source was prepared by solution cast technique. The electrolyte with the highest conductiv...

(This article belongs to the Special Issue Advanced Materials for Electrochemical Energy Conversion and Storage Devices)
  • Article
  • Open Access
17 Citations
4,173 Views
20 Pages

The Study of Structural, Impedance and Energy Storage Behavior of Plasticized PVA:MC Based Proton Conducting Polymer Blend Electrolytes

  • Shujahadeen B. Aziz,
  • Iver Brevik,
  • M. A. Brza,
  • A. S. F. M. Asnawi and ,
  • Elham M. A. Dannoun,
  • Y. M. Yusof,
  • Rebar T. Abdulwahid,
  • M. H. Hamsan,
  • Muaffaq M. Nofal and
  • M. F. Z. Kadir
  • + 5 authors+ 0 author

7 November 2020

In this study, structural characterization, electrical properties and energy storage performance of plasticized polymer electrolytes based on polyvinyl alcohol/methylcellulose/ammonium thiocyanate (PVA/MC-NH4SCN) were carried out. An X-ray diffractio...

(This article belongs to the Special Issue Functionalization, Characterization, and Applications of Polymeric and Hybrid Materials)
  • Article
  • Open Access
51 Citations
9,994 Views
16 Pages

A Comparative Study of Equivalent Circuit Models for Electro-Chemical Impedance Spectroscopy Analysis of Proton Exchange Membrane Fuel Cells

  • Lei Zhao,
  • Haifeng Dai,
  • Fenglai Pei,
  • Pingwen Ming and ,
  • Xuezhe Wei and
  • Jiangdong Zhou
  • + 1 author+ 0 author

5 January 2022

Electrochemical impedance spectroscopy is one of the important tools for the performance analysis and diagnosis of proton exchange membrane fuel cells. The equivalent circuit model is an effective method for electrochemical impedance spectroscopy res...

(This article belongs to the Collection Batteries, Fuel Cells and Supercapacitors Technologies)
  • Article
  • Open Access
15 Citations
3,760 Views
22 Pages

15 November 2020

Pharmacological efficiency of active compounds is largely determined by their membrane permeability. Thus, identification of drug-membrane interactions seems to be a crucial element determining drug-like properties of chemical agents. Yet, knowledge...

(This article belongs to the Special Issue Electrical Properties of Model Lipid Membranes)
  • Article
  • Open Access
7 Citations
2,806 Views
10 Pages

31 May 2022

In the currently used primary impedance measuring systems, there is a need to compare standards with ratios different from 1:1, e.g., in order to transfer the value to multiples or submultiples of the basic quantity. Unfortunately, the commercial PXI...

(This article belongs to the Special Issue Measurement Applications in Industry 4.0)
  • Proceeding Paper
  • Open Access
1 Citations
1,814 Views
4 Pages

Study of Lead-Free Ferroelectric Composite Coatings by Impedance Spectroscopy

  • Mariya Aleksandrova,
  • Ivailo Pandiev,
  • Tsvetozar Tsanev and
  • Georgi Dobrikov

Abstract: The aim of the study is the preparation and electrical characterization of lead-free ferroelectric oxide BaSrTiO3 in the composition with a piezoelectric polymer. The properties of the deposited films were compared with pristine oxide. Atom...

(This article belongs to the Proceedings of 2nd Coatings and Interfaces Web Conference (CIWC-2 2020))
  • Article
  • Open Access
83 Citations
9,759 Views
14 Pages

Study on the Carbonation Behavior of Cement Mortar by Electrochemical Impedance Spectroscopy

  • Biqin Dong,
  • Qiwen Qiu,
  • Jiaqi Xiang,
  • Canjie Huang and ,
  • Feng Xing and
  • Ningxu Han
  • + 1 author+ 0 author

3 January 2014

A new electrochemical model has been carefully established to explain the carbonation behavior of cement mortar, and the model has been validated by the experimental results. In fact, it is shown by this study that the electrochemical impedance behav...

  • Article
  • Open Access
110 Citations
7,943 Views
13 Pages

23 October 2014

Piezoelectric lead zirconate titanate (PZT) is being gradually applied into practice as a new intelligent material for structural health monitoring. In order to study the damage detection properties of PZT on concrete slabs, simply supported reinforc...

(This article belongs to the Section Physical Sensors)
  • Article
  • Open Access
17 Citations
7,829 Views

Electrochemical Impedance Spectroscopy Study of Waterborne Epoxy Coating Film Formation

  • Natalija Končan Volmajer,
  • Miha Steinbücher,
  • Peter Berce,
  • Peter Venturini and
  • Miran Gaberšček

16 April 2019

The film formation process in waterborne (WB) epoxy coatings is studied using electrochemical impedance spectroscopy (EIS) measurements and dynamic mechanical analysis (DMA). Ten epoxy coatings with different pigment volume concentration were prepare...

  • Article
  • Open Access
104 Views
17 Pages

Nanowell Impedance Sensors: A Study of Physical Characteristics, Biocompatibility, and Multiplexing Performance

  • Hassan Raji,
  • Suneel Kumar,
  • Gulam M. Rather,
  • Zhuolun Meng and ,
  • Pengfei Xie,
  • Dhruv Patel,
  • Francois Berthiaume and
  • Mehdi Javanmard
  • + 3 authors+ 0 author

26 November 2026

Nanowell impedance sensors offer enhanced sensitivity, label-free detection, and real-time monitoring capabilities, making them ideal for precise biomolecule detection and analysis. Despite extensive research, further characterization is required to...

(This article belongs to the Special Issue Advanced Biosensors: Nanomaterials, Micro/Nano Devices and Applications)
  • Article
  • Open Access
2 Citations
2,403 Views
11 Pages

Experimental Study on the Impact of Flow Rate Strategies on the Mass Transfer Impedance of PEM Electrolyzers

  • Haoyu Zhang,
  • Jiangong Zhu,
  • Chao Wang,
  • Hao Yuan and ,
  • Haifeng Dai and
  • Xuezhe Wei
  • + 1 author+ 0 author

23 May 2025

The flow rate strategies of deionized water have a significant impact on the mass transfer process of proton exchange membrane (PEM) electrolyzers, which are critical for the efficient and safe operation of hydrogen production systems. Electrochemica...

(This article belongs to the Section J1: Heat and Mass Transfer)
  • Article
  • Open Access
233 Views
18 Pages

30 October 2026

Intraoperative tissue trauma during cochlear implant (CI) insertion remains a primary cause of residual hearing loss. Because insertion currently relies largely on clinician experience without direct visualization within the optically obscured inner...

(This article belongs to the Special Issue The Sensing Technologies and Computational Methods for Biomedical Engineering: Next-Generation Perspectives)
  • Article
  • Open Access
2,481 Views
11 Pages

Abdominal Aortic Aneurysm Detection in Bioelectrical Impedance Cardiovascular Screenings—A Pilot Study

  • Amun G. Hofmann,
  • Tarik Shoumariyeh,
  • Christoph Domenig,
  • Falko Skrabal and
  • Johannes J. Kovarik

28 May 2023

Screening and diagnosing abdominal aortic aneurysms (AAA) are currently dependent on imaging studies such as ultrasound or computed tomography angiography. All imaging studies offer distinct advantages but also suffer from inherent limitations such a...

(This article belongs to the Special Issue Advances in Vascular and Endovascular Surgery)
  • Article
  • Open Access
2 Citations
1,969 Views
7 Pages

Novel Impedance-pH Parameters in Pre-Bariatric Assessment of Patients: A Pilot Study

  • Mario Gagliardi,
  • Antonella Santonicola,
  • Rossella Palma,
  • Luigi Angrisani and ,
  • Nigel J. Trudgill and
  • Paola Iovino
  • + 1 author+ 0 author

25 January 2023

Novel impedance-pH parameters, Mean Nocturnal Baseline Impedance (MNBI) and Post-Reflux Swallow-Induced Peristaltic Wave (PSPW) index, have been proposed to improve the gastro-esophageal reflux disease (GERD) diagnostic yield. This study aims to dete...

(This article belongs to the Section Gastroenterology & Hepatopancreatobiliary Medicine)
  • Article
  • Open Access
23 Citations
3,931 Views
10 Pages

Does Body Position Influence Bioelectrical Impedance? An Observational Pilot Study

  • Paweł Więch,
  • Filip Wołoszyn,
  • Patrycja Trojnar,
  • Mateusz Skórka and
  • Dariusz Bazaliński

As the availability of various bioelectric impedance analysis (BIA) tools is increasing, the patient’s position during the test may be of significant importance for the comparability of the results. An observational pilot study was undertaken b...

(This article belongs to the Special Issue Application of Bioelectrical Impedance Analysis (BIA) in Human Health and Life)
  • Article
  • Open Access
83 Citations
6,306 Views
24 Pages

Employing of Trukhan Model to Estimate Ion Transport Parameters in PVA Based Solid Polymer Electrolyte

  • Shujahadeen B. Aziz,
  • Rawezh B. Marif,
  • M. A. Brza,
  • M. H. Hamsan and
  • M. F. Z. Kadir

16 October 2019

In the current paper, ion transport parameters in poly (vinyl alcohol) (PVA) based solid polymer electrolyte were examined using Trukhan model successfully. The desired amount of lithium trifluoromethanesulfonate (LiCF3SO3) was dissolved in PVA host...

(This article belongs to the Section Polymer Applications)
  • Article
  • Open Access
25 Citations
10,431 Views
16 Pages

Study of Paclitaxel-Treated HeLa Cells by Differential Electrical Impedance Flow Cytometry

  • Julie Kirkegaard,
  • Casper Hyttel Clausen,
  • Romen Rodriguez-Trujillo and
  • Winnie Edith Svendsen

13 August 2014

This work describes the electrical investigation of paclitaxel-treated HeLa cells using a custom-made microfluidic biosensor for whole cell analysis in continuous flow. We apply the method of differential electrical impedance spectroscopy to treated...

(This article belongs to the Special Issue Label-Free Biosensors: Exploring the Field)
  • Article
  • Open Access
7 Citations
6,604 Views
22 Pages

10 August 2023

Recent advances in commercially available integrated complex impedance spectroscopy controllers have brought rapid increases in the quality of systems available to researchers for wearable and remote patient monitoring applications. As a result, nove...

  • Article
  • Open Access
2 Citations
2,982 Views
15 Pages

Detection of Salt Content in Canned Tuna by Impedance Spectroscopy: A Feasibility Study for Distinguishing Salt Levels

  • Inés Zabala,
  • Santos Merino,
  • Unai Eletxigerra,
  • Jorge Ramiro and ,
  • Miren Burguera and
  • Estibaliz Aranzabe
  • + 1 author+ 0 author

4 June 2024

The electrical impedance of dilute aqueous solutions containing extracts from five brands of canned tuna is analyzed using impedance spectroscopy in order to analyze their salt content and detect the potential presence of other salts beyond the well-...

(This article belongs to the Special Issue Rapid Analysis Technology for Quality Control and Food Safety)
  • Article
  • Open Access
268 Citations
14,588 Views
20 Pages

An Experimental Study on the Effect of Temperature on Piezoelectric Sensors for Impedance-Based Structural Health Monitoring

  • Fabricio G. Baptista,
  • Danilo E. Budoya,
  • Vinicius A. D. de Almeida and
  • Jose Alfredo C. Ulson

10 January 2014

The electromechanical impedance (EMI) technique is considered to be one of the most promising methods for developing structural health monitoring (SHM) systems. This technique is simple to implement and uses small and inexpensive piezoelectric sensor...

(This article belongs to the Section Physical Sensors)
  • Article
  • Open Access
19 Citations
4,506 Views
19 Pages

3 October 2020

Background: Electrical impedance spectroscopy (EIS) is a fast, non-invasive, and safe approach for electrical impedance measurement of biomedical tissues. Applied to dental research, EIS has been used to detect tooth cracks and caries with higher acc...

(This article belongs to the Section Complexity)
  • Article
  • Open Access
1,301 Views
15 Pages

1 May 2025

To prevent pogo oscillation in liquid launch vehicles, it is essential to install a gas-filled accumulator near the pump with minimum flow inertance and a target-design level of flow resistance, which are the real and imaginary parts of communication...

(This article belongs to the Section Aerospace Science and Engineering)
  • Article
  • Open Access
15 Citations
5,574 Views
18 Pages

An Effective Method of Detecting Characteristic Points of Impedance Cardiogram Verified in the Clinical Pilot Study

  • Ilona Karpiel,
  • Monika Richter-Laskowska,
  • Daniel Feige,
  • Adam Gacek and
  • Aleksander Sobotnicki

15 December 2022

Accurate and reliable determination of the characteristic points of the impedance cardiogram (ICG) is an important research problem with a growing range of applications in the cardiological diagnostics of patients with heart failure (HF). The shapes...

(This article belongs to the Special Issue ECG Signal Processing Techniques and Applications)
  • Article
  • Open Access
21 Citations
4,624 Views
15 Pages

25 September 2017

Today, the characterisation of the microstructure of cement-based materials using non-destructive techniques has become an important topic of study, and among them, the impedance spectroscopy has recently experienced great progress. In this research,...

  • Article
  • Open Access
9 Citations
2,258 Views
18 Pages

22 September 2022

There are a huge number of harmonics in the railway power supply system. Accurately estimating the harmonic impedance of the system is the key to evaluating the harmonic emission level of the power supply system. A harmonic impedance estimation metho...

(This article belongs to the Section F: Electrical Engineering)
  • Article
  • Open Access
12 Citations
5,374 Views
13 Pages

In human body communication (HBC) systems, radio-frequency signals are excited in the human body through a wearable antenna comprised of electrodes that are in contact with the surface of the body. The input impedance characteristics of these antenna...

(This article belongs to the Special Issue Bio-Information and Human Body Communication for Ubiquitous Healthcare)
  • Article
  • Open Access
3 Citations
1,858 Views
17 Pages

1 February 2025

In recent years, various types of sensors have been developed at both millimeter (mm) and micrometer (µm) scales for numerous biomedical applications. Each design has its own advantages and limitations. This study compares the electrical charac...

(This article belongs to the Collection Advances in Microtechnology for Cell/Tissue Engineering and Biosensing)
  • Feature Paper
  • Article
  • Open Access
8 Citations
4,217 Views
31 Pages

24 May 2018

This paper presents an analytical model, oriented to study harmonic mitigation aspects in AC grids. As it is well known, the presence of non-desired harmonics in AC grids can be palliated in several manners. However, in this paper, a power electronic...

(This article belongs to the Section F: Electrical Engineering)
  • Article
  • Open Access
145 Views
25 Pages

21 November 2026

Traditional chemical analysis methods for beverage quality control are accurate but time-consuming, labor-intensive, and unsuitable for real-time industrial monitoring. This study investigates a compact broadband spectroscopic sensing system based on...

(This article belongs to the Special Issue Spectroscopic Sensors and Spectral Analysis)
  • Article
  • Open Access
4,784 Views
14 Pages

17 September 2021

The current diagnostic procedures for assessing physiological response to exercise comprise blood lactates measurements, ergospirometry, and electrocardiography. The first is not continuous, the second requires specialized equipment distorting natura...

(This article belongs to the Special Issue Sensors and Methods for the Measurement of Cardiovascular and Respiratory Systems)
  • Article
  • Open Access
17 Citations
6,393 Views
17 Pages

8 September 2017

This study investigates the emerging harmonic stability concerns to be addressed by grid planners in generation interconnection studies, owing to the increased adoption of renewable energy resources connected to the grid via power electronic converte...

  • Article
  • Open Access
7 Citations
3,201 Views
16 Pages

27 August 2021

As a key load-bearing element in a prestressed structure, the anchor should be appropriately monitored to secure its as-built prestressing force. In previous studies, the impedance-based prestress force monitoring technique through a mountable lead–Z...

(This article belongs to the Special Issue Advanced Methodologies and Technologies in Structural Monitoring)
  • Article
  • Open Access
1 Citations
565 Views
17 Pages

Towards Sustainable Management of Construction Site Wastewater: A Case Study Using Electrocoagulation and Impedance Spectroscopy

  • Soukaina Bakkass,
  • Naoual Semlali Aouragh Hassani,
  • Mohammed Karim Ben Hachmi,
  • Abdellatif Aarfane and ,
  • Hamid Nasrellah and
  • Halima Mortadi
  • + 1 author+ 0 author

23 June 2026

Construction sites generate large volumes of contaminated wastewater, yet sustainable treatment solutions remain limited. This study presents a case study focusing on the wastewater produced from washing construction equipment at an industrial site i...

(This article belongs to the Section C. Building Energy, Physics, Environment, and Systems)
  • Proceeding Paper
  • Open Access
150 Views
9 Pages

Electrical Impedance Spectroscopy Study of Bubble-Associated Interfacial Changes in Physiological Saline Solution Under DC Excitation

  • Jânio Anselmo,
  • Douglas Molter Ferreira,
  • Juan Alberto González Cuevas,
  • Julio César dos Santos and ,
  • Gustavo Ferreira Nicoluzzi,
  • Guilherme Brasil Pintarelli and
  • Daniela Ota Hisayasu Suzuki
  • + 2 authors+ 0 author

27 October 2026

Gas bubble evolution at electrified electrode–electrolyte interfaces and concurrent Faradaic processes change the electroactive area and the local current-density distribution and thereby the measured electrical impedance. This study investigat...

(This article belongs to the Proceedings of The 13th International Electronic Conference on Sensors and Applications)
  • Article
  • Open Access
8 Citations
4,230 Views
14 Pages

Impedance Spectroscopic Study of Nickel Sulfide Nanostructures Deposited by Aerosol Assisted Chemical Vapor Deposition Technique

  • Sadia Iram,
  • Azhar Mahmood,
  • Muhammad Fahad Ehsan,
  • Asad Mumtaz and ,
  • Manzar Sohail,
  • Effat Sitara,
  • Syeda Aqsa Batool Bukhari,
  • Sumia Gul,
  • Syeda Arooj Fatima and
  • Mohammad Azad Malik
  • + 8 authors+ 3 authors

24 April 2021

This research aims to synthesize the Bis(di-isobutyldithiophosphinato) nickel (II) complex [Ni(iBu2PS2)] to be employed as a substrate for the deposition of nickel sulfide nanostructures, and to investigate its dielectric and impedance characteristic...

(This article belongs to the Section Synthesis, Interfaces and Nanostructures)
  • Article
  • Open Access
6 Citations
5,465 Views
10 Pages

Wearable devices are gaining recognition for their use as a biosensor platform. Electrical impedance tomography (EIT) is one of the sensing techniques that utilizes wearable sensors as its primary data acquisition system. It measures the impedance or...

  • Article
  • Open Access
6 Citations
5,647 Views
16 Pages

9 November 2020

In this study, we propose a new short-time impedance spectroscopy method with the following three features: (1) A frequency spectrum of complex impedance for the measured object can be obtained even when the measuring electrodes are capacitively coup...

(This article belongs to the Section Intelligent Sensors)
  • Article
  • Open Access
2 Citations
2,828 Views
16 Pages

The evolution of power electronics led to rapid development in wireless charging technology; as a result, a single active switch topology was introduced. The present market utilizes inductive wireless power transfer (IPT); because of the disadvantage...

(This article belongs to the Section Power Electronics)
  • Article
  • Open Access
93 Citations
5,590 Views
22 Pages

High Proton Conducting Polymer Blend Electrolytes Based on Chitosan:Dextran with Constant Specific Capacitance and Energy Density

  • Shujahadeen B. Aziz,
  • M. H. Hamsan,
  • Wrya O. Karim,
  • M. F. Z. Kadir and ,
  • M. A. Brza and
  • Omed Gh. Abdullah
  • + 1 author+ 0 author

Polymer blend electrolytes based on chitosan: dextran (CS:Dext) incorporated with various amounts of ammonium fluoride (NH4F) with constant specific capacitance (12.4 F/g) and energy density over 100 cycles were prepared using a solution cast techniq...

(This article belongs to the Special Issue Carbohydrate Polymers: Science and Applications)
  • Article
  • Open Access
1 Citations
1,805 Views
14 Pages

Experimental Study on Impedance Spectrum-Based Detection of Water Holdup in Two-Phase Flow under Complex Salinity Conditions

  • Linfeng Cheng,
  • Shizhen Ke,
  • Hongwei Shi,
  • Yuhang Zhang and ,
  • Hu Luo and
  • Hao Hu
  • + 1 author+ 0 author

19 July 2024

In industrial production and water resource management involving fluid flows, two-phase flow measurement in complex environments has always been a research hotspot. In this study, a broadband detection device (40–110 MHz) suitable for two-phase...

(This article belongs to the Special Issue Quantifying Groundwater Flow and Solute Transport Processes through Modelling and Experiments)
  • Article
  • Open Access
13 Citations
2,868 Views
19 Pages

An Experimental Study of Damage Detection on Typical Joints of Jackets Platform Based on Electro-Mechanical Impedance Technique

  • Liaqat Ali,
  • Sikandar Khan,
  • Naveed Iqbal,
  • Salem Bashmal and ,
  • Hamad Hameed and
  • Yong Bai
  • + 1 author+ 0 author

25 November 2021

Many methods have been used in the past two decades to detect crack damage in steel joints of the offshore structures, but the electromechanical impedance (EMI) method is a comparatively recent non-destructive method that can be used for quality moni...

(This article belongs to the Special Issue Underwater Processing of Materials)
  • Article
  • Open Access
24 Citations
4,802 Views
14 Pages

18 October 2018

Interlayer slide damage is one of the main causes of landslide hazard, inflicting huge economic losses and casualties. It is urgent to accurately detect the initiation and development of the interlayer slide damage in real time. In this paper, a stud...

(This article belongs to the Special Issue Recent Advances of Piezoelectric Transducers and Applications)
  • Article
  • Open Access
3 Citations
3,043 Views
15 Pages

First Ex Vivo Animal Study of a Biological Heart Valve Prosthesis Sensorized with Intravalvular Impedance

  • Laura Cercenelli,
  • Camilla Gironi,
  • Barbara Bortolani and
  • Emanuela Marcelli

8 April 2023

IntraValvular Impedance (IVI) sensing is an innovative concept for monitoring heart valve prostheses after implant. We recently demonstrated IVI sensing feasible in vitro for biological heart valves (BHVs). In this study, for the first time, we inves...

(This article belongs to the Special Issue Novel Implantable Sensors and Biomedical Applications)
  • Article
  • Open Access

Association Between an Electrochemical Impedance Parameter of Bone and Dental Implant Primary Stability: An Ex Vivo Study on Bovine Bone

  • Fulvio Guercio,
  • Federico Izzo,
  • Teresa Lombardi,
  • Gaetano Marenzi and ,
  • Raffaele Vinci and
  • Claudio Stacchi
  • + 1 author+ 0 author
Materials2026, 19(23), 5090;https://doi.org/10.3390/ma19235090 
(registering DOI)

29 November 2026

Bone density at the implant site is still assessed subjectively, with high inter- and intra-observer variability. This ex vivo study evaluated the repeatability of electrochemical impedance spectroscopy (EIS) of bone and its correlation with implant...

(This article belongs to the Special Issue Advanced Restorative and Implant Materials for Bioengineering)
  • Review
  • Open Access
18 Citations
6,899 Views
16 Pages

Applications of Bioelectrical Impedance Vector Analysis (BIVA) in the Study of Body Composition in Athletes

  • Sandra de la Cruz Marcos,
  • Mª Paz Redondo del Río and
  • Beatriz de Mateo Silleras

20 October 2021

The study of body composition (BC) allows evaluating nutritional status, optimizing competitive performance, and monitoring the success of training regimens in athletes. Since BC reference techniques are expensive and/or invasive, in practice simpler...

(This article belongs to the Special Issue Anthropometry and Body Composition for Health, Disease and Sport: Application and Technologies)

of 196