Skip to Content

166 Results Found

  • Article
  • Open Access
17 Citations
5,476 Views
16 Pages

19 January 2018

For high-power and high-performance speed control system, speed feedback signals are generally required. The employment of sensorless control technology makes the installation of the system easier and lower-cost, while its reliability needs to be imp...

  • Article
  • Open Access
4 Citations
1,842 Views
22 Pages

26 December 2024

After eliminating the speed sensor in the linear induction motor (LIM) high-performance closed-loop control system, the speed feedback information is missing in the speed closed loop. The accuracy of speed observation results is affected by changes i...

(This article belongs to the Special Issue Advanced Theory and Application of Magnetic Actuators—2nd Edition)
  • Article
  • Open Access
11 Citations
2,852 Views
18 Pages

6 November 2022

In the speed control system of an Interior Permanent Magnet Synchronous Motor (IPMSM) without a speed sensor, PI controllers using only a fixed set of parameters cannot achieve accurate tracking of the estimated speed in a wide speed domain and also...

(This article belongs to the Section F: Electrical Engineering)
  • Article
  • Open Access
6 Citations
2,625 Views
18 Pages

11 April 2023

This paper introduces a sensorless nonlinear control scheme based on feedback linearization control (FLC) of an open-end winding five-phase induction motor (OeW-5PIM) topology fed by a dual neutral point clamped (NPC) inverter. The suggested sensorle...

(This article belongs to the Section Electrical Machines and Drives)
  • Article
  • Open Access
6 Citations
4,954 Views
11 Pages

Purpose: The purpose of this study is to improve the qualitative and quantitative image quality of the time-resolved angiography with interleaved stochastic trajectories technique (4D-TWIST-MRA) using deep neural network (DNN)-based MR image reconstr...

(This article belongs to the Special Issue Clinical Advances and Applications in Neuroradiology)
  • Article
  • Open Access
3 Citations
1,846 Views
10 Pages

Negative Prognostic Impact of Mineralocorticoid Receptor Antagonist in Elderly Patients Receiving TAVR

  • Teruhiko Imamura,
  • Nikhil Narang,
  • Hiroshi Onoda,
  • Shuhei Tanaka and ,
  • Ryuichi Ushijima,
  • Mitsuo Sobajima,
  • Nobuyuki Fukuda,
  • Hiroshi Ueno and
  • Koichiro Kinugawa
  • + 4 authors+ 0 author

29 May 2023

Background: Morbidity and mortality following trans-catheter aortic valve replacement (TAVR) remain high. Renin-angiotensin system inhibitors improve clinical outcomes in the cohort studied in this work. However, post-TAVR prognostic impact of minera...

(This article belongs to the Topic Recent Advances in the Diagnosis and Treatment of Aortic Valve Disease)
  • Article
  • Open Access
8 Citations
4,528 Views
15 Pages

Diagnostic Accuracy of Non-Contrast-Enhanced Time-Resolved MR Angiography to Assess Angioarchitectural Classification Features of Brain Arteriovenous Malformations

  • Grégoire Chauvet,
  • Mourad Cheddad El Aouni,
  • Elsa Magro,
  • Ophélie Sabardu and ,
  • Douraied Ben Salem,
  • Jean-Christophe Gentric and
  • Julien Ognard
  • + 2 authors+ 0 author

This study aims to assess the diagnostic accuracy of non-contrast-enhanced 4D MR angiography (NCE-4D-MRA) compared to contrast-enhanced 4D MR angiography (CE-4D-MRA) for the detection and angioarchitectural characterisation of brain arteriovenous mal...

(This article belongs to the Special Issue Advances in Cerebrovascular Imaging and Interventions)
  • Article
  • Open Access
11 Citations
5,968 Views
10 Pages

Common Carotid Artery Volume Flow: A Comparison Study between Ultrasound Vector Flow Imaging and Phase Contrast Magnetic Resonance Imaging

  • Andreas Hjelm Brandt,
  • Jacob Bjerring Olesen,
  • Ramin Moshavegh,
  • Jørgen Arendt Jensen and ,
  • Michael Bachmann Nielsen and
  • Kristoffer Lindskov Hansen
  • + 1 author+ 0 author

23 June 2021

Volume flow estimation in the common carotid artery (CCA) can assess the absolute hemodynamic effect of a carotid stenosis. The aim of this study was to compare a commercial vector flow imaging (VFI) setup against the reference method magnetic resona...

  • Article
  • Open Access
19 Citations
3,896 Views
19 Pages

24 September 2022

To solve the problem of the sensorless control method of a permanent magnet synchronous motor, based on the study of a mathematical model for a permanent magnet synchronous motor and model adaptation theory, a reference model equation and adjustable...

  • Article
  • Open Access
18 Citations
7,250 Views
13 Pages

Beneficial Effects of Mineralocorticoid Receptor Antagonism on Myocardial Fibrosis in an Experimental Model of the Myxomatous Degeneration of the Mitral Valve

  • Jaime Ibarrola,
  • Mattie Garaikoetxea,
  • Amaia Garcia-Peña,
  • Lara Matilla and ,
  • Eva Jover,
  • Benjamin Bonnard,
  • Maria Cuesta,
  • Amaya Fernández-Celis,
  • Frederic Jaisser and
  • Natalia López-Andrés
  • + 5 authors+ 0 author

Mitral valve prolapse (MVP) patients develop myocardial fibrosis that is not solely explained by volume overload, but the pathophysiology has not been defined. Mineralocorticoid receptor antagonists (MRAs) improve cardiac function by decreasing cardi...

(This article belongs to the Special Issue Extracellular Matrix in Heart Disease)
  • Systematic Review
  • Open Access
5 Citations
3,123 Views
15 Pages

Mineralocorticoid Receptor Antagonists in Heart Failure with Preserved Ejection Fraction: A Systematic Review and Meta-Analysis

  • Mithila Zaheen,
  • Fardin Ferdous,
  • Anjalee T. Amarasekera,
  • Johannes Petutschnigg and ,
  • Frank Edelmann and
  • Timothy C. Tan
  • + 1 author+ 0 author

21 May 2025

Background/Objectives: Heart failure with preserved ejection fraction (HFpEF) is a complex clinical syndrome with limited therapeutic options. Mineralocorticoid receptor antagonists (MRAs) have been shown to improve clinical outcomes in patients with...

(This article belongs to the Section Cardiology)
  • Review
  • Open Access
7 Citations
5,236 Views
17 Pages

18 January 2023

Inappropriate mineralocorticoid receptor (MR) activation in different cardiovascular cell types has deleterious effects on cardiac remodeling and function. Therefore, MR inhibition is a crucial pharmacological strategy to overcome cardiovascular dysf...

(This article belongs to the Special Issue Renin-Angiotensin-Aldosterone System in Metabolism and Disease)
  • Article
  • Open Access
211 Views
34 Pages

Piecewise Linear Fuzzy Adaptive Speed Observer with Torque Error Compensation for Electric Vehicle Traction Drives

  • Saqib Jamshed Rind,
  • Saba Javed,
  • Hashim Raza Khan,
  • Khaled Assaleh and
  • Kamran Arshad

This paper presents a piecewise-linear single-input fuzzy-controller-based model reference adaptive system (SFC-MRAS) for speed estimation in speed-sensorless vector-controlled induction motor drives for electric vehicle (EV) traction applications. C...

(This article belongs to the Section Propulsion Systems and Components)
  • Article
  • Open Access
1 Citations
1,067 Views
20 Pages

29 November 2025

This paper presents a sensorless control strategy for a six-phase induction generator (6PIG) operating at low speed (125 rpm). The proposed approach is based on the Model Reference Adaptive System (MRAS), with an initial estimation scheme developed u...

(This article belongs to the Special Issue Design and Production Process Optimization for High Performance and Energy Efficiency in Electrical Machines—2nd Edition)
  • Article
  • Open Access
12 Citations
3,564 Views
17 Pages

The Effect of Mineralocorticoid Receptor 3 Antagonists on Anti-Inflammatory and Anti-Fatty Acid Transport Profile in Patients with Heart Failure

  • Xiaoran Fu,
  • Cristina Almenglo,
  • Ángel Luis Fernandez,
  • José Manuel Martínez-Cereijo and ,
  • Diego Iglesias-Alvarez,
  • Darío Duran-Muñoz,
  • Tomás García-Caballero,
  • Jose Ramón Gonzalez-Juanatey,
  • Moises Rodriguez-Mañero and
  • Sonia Eiras
  • + 5 authors+ 0 author

8 April 2022

Epicardial fat thickness is associated with cardiovascular disease. Mineralocorticoid receptor antagonist (MRA), a pharmaceutical treatment for CVD, was found to have an effect on adipose tissue. Our aim was to analyse the main epicardial fat genesis...

(This article belongs to the Special Issue Adipose Tissue in Cardiovascular Health)
  • Article
  • Open Access
3 Citations
6,445 Views
10 Pages

29 December 2022

This study aimed to optimize velocity-selective magnetic resonance angiography (VS-MRA) protocols for whole-neck angiography and demonstrate its feasibility in healthy subjects with comparisons to clinical 3D time-of-flight (TOF) angiography. To help...

(This article belongs to the Section Cardiovascular Imaging)
  • Article
  • Open Access
5 Citations
1,406 Views
16 Pages

29 May 2024

To improve the speed observation accuracy of the bearingless induction motor (BL-IM) and achieve its high-performance speed sensorless control, an improved sliding mode variable structure model reference adaptive system speed identification method ba...

(This article belongs to the Special Issue Advanced Topologies and Control Strategies in Electric Machines and Drives)
  • Article
  • Open Access
17 Citations
2,815 Views
20 Pages

28 August 2023

This paper introduces a parameter-estimation-based sensorless adaptive direct voltage maximum torque per ampere (MTPA) control strategy for interior permanent magnet synchronous machines (IPMSMs). In direct voltage control, the motor’s electric...

(This article belongs to the Section Electromechanical Energy Conversion Systems)
  • Brief Report
  • Open Access
1 Citations
1,759 Views
9 Pages

Impact of Various Non-Contrast-Enhanced MRA Techniques on Lumen Visibility in Vascular Flow Models with a Surpass Evolve Flow Diverter

  • Yigit Ozpeynirci,
  • Margarita Gorodezky,
  • Augusto Fava Sanches,
  • Sagar Mandava and ,
  • Ana Beatriz Solana and
  • Thomas Liebig
  • + 1 author+ 0 author

Background: Silent MRA has shown promising results in evaluating the stents used for intracranial aneurysm treatment. A deep learning-based denoising and deranging algorithm was recently introduced by GE HealthCare. The purpose of this study was to c...

(This article belongs to the Special Issue Deep Learning for Medical Imaging Diagnosis)
  • Article
  • Open Access
9 Citations
3,645 Views
21 Pages

27 June 2020

Mixed recycled aggregates (MRA) from construction and demolition waste (CDW) with high-purity and environmental performance are required for highway construction application in base layer and precast concrete curbs. The main problematic constituents...

(This article belongs to the Special Issue Silicate Solid Waste Recycling)
  • Article
  • Open Access
7 Citations
2,149 Views
27 Pages

Control Strategy of Flywheel Energy Storage System for Improved Model Reference Adaptive System Based on Tent-Sparrow Search Algorithm

  • Gengling Song,
  • Zhenkui Wu,
  • Xuechen Zheng,
  • Jihong Zhang and ,
  • Peihong Yang and
  • Zilei Zhang
  • + 1 author+ 0 author

This study addresses speed sensor aging and electrical parameter variations caused by prolonged operation and environmental factors in flywheel energy storage systems (FESSs). A model reference adaptive system (MRAS) flywheel speed observer with para...

  • Article
  • Open Access
2 Citations
3,051 Views
13 Pages

13 November 2020

Radial ultrasonic rolling electrochemical micromachining (RUR-EMM) is a new method of electrochemical machining (ECM). By feeding small and rotating electrodes aided by ultrasonic rolling, an array of pits can be manufactured, which is called microst...

(This article belongs to the Special Issue Advances in Micro and Nano Manufacturing: Process Modeling and Applications)
  • Article
  • Open Access
2 Citations
2,559 Views
19 Pages

19 October 2021

Mathematical models of induction motor (IM) used in direct field-oriented control (DFOC) strategies are characterized by parametrization resulting from the IM equivalent circuit and model-type selection. The parameter inaccuracy causes DFOC detuning,...

(This article belongs to the Special Issue Modeling and Simulation of Power Systems and Power Electronics)
  • Article
  • Open Access
1 Citations
1,740 Views
19 Pages

23 February 2024

Gridshell structures are characterized by an impressive strength-to-weight ratio, allowing their application in large-span roofing structures. However, their complex construction process and maintenance limited their widespread application. In recent...

(This article belongs to the Section Building Structures)
  • Article
  • Open Access
4 Citations
2,636 Views
13 Pages

Dynamic Radial MR Imaging for Endoleak Surveillance after Endovascular Repair of Abdominal Aortic Aneurysms with Inconclusive CT Angiography: A Prospective Study

  • Haidara Almansour,
  • Migdat Mustafi,
  • Mario Lescan,
  • Ulrich Grosse and ,
  • Mateja Andic,
  • Jörg Schmehl,
  • Christoph Artzner,
  • Gerd Grözinger and
  • Sven S. Walter
  • + 4 authors+ 0 author

15 May 2024

Background/Objectives: To assess free-breathing, dynamic radial magnetic resonance angiography (MRA) for detecting endoleaks post-endovascular aortic repair (EVAR) in cases with inconclusive computed tomography angiography (CTA). Methods: This prospe...

(This article belongs to the Special Issue Current Trends in Vascular and Endovascular Surgery)
  • Review
  • Open Access
9 Citations
9,437 Views
14 Pages

Finerenone: A Third-Generation MRA and Its Impact on Cardiovascular Health—Insights from Randomized Controlled Trials

  • Michael Sabina,
  • Jennifer Trube,
  • Shrinand Shah,
  • Andrew Lurie and ,
  • Mason Grimm and
  • Anas Bizanti
  • + 1 author+ 0 author

25 October 2024

Introduction: Finerenone, a third-generation non-steroidal mineralocorticoid receptor antagonist (MRA), offers a targeted approach to managing cardiovascular outcomes, particularly in patients with chronic kidney disease (CKD) and type 2 diabetes (T2...

(This article belongs to the Section Cardiovascular Medicine)
  • Systematic Review
  • Open Access
8 Citations
6,488 Views
23 Pages

Mineralocorticoid Receptor Antagonists and Cognitive Outcomes in Cardiovascular Disease and Beyond: A Systematic Review

  • Paola Pastena,
  • Gabriele Campagnoli,
  • Ali Reza Rahmani and
  • Andreas P. Kalogeropoulos

30 January 2025

Background/Objectives: Cognitive impairment is a debilitating comorbidity affecting diverse patient populations, yet the cognitive effects of therapies like mineralocorticoid receptor antagonists (MRAs) remain underexplored. Preclinical evidence sugg...

(This article belongs to the Section Mechanisms of Diseases)
  • Article
  • Open Access
15 Citations
4,297 Views
14 Pages

6 November 2023

Aiming at the problem that online parameter identification, based on the Model Reference Adaptive System (MRAS), is easily affected by the high-frequency noise of the sensor, an improved MRAS, based on variable bandwidth linear Active Disturbance Rej...

(This article belongs to the Section Electrical, Electronics and Communications Engineering)
  • Article
  • Open Access
40 Citations
4,297 Views
16 Pages

Modeling and Prediction of Surface Roughness in Hybrid Manufacturing–Milling after FDM Using Artificial Neural Networks

  • Strahinja Djurović,
  • Dragan Lazarević,
  • Bogdan Ćirković,
  • Milan Mišić and ,
  • Milan Ivković,
  • Bojan Stojčetović,
  • Martina Petković and
  • Aleksandar Ašonja
  • + 3 authors+ 0 author

9 July 2024

Three-dimensional printing, or additive manufacturing, represents one of the fastest growing branches of the industry, and fused deposition modeling (FDM) is one of most frequently used technologies. Three-dimensional printing does not provide high-q...

(This article belongs to the Special Issue 3D Printing Technologies and Additive Manufacturing: Recent Advances and Applications)
  • Article
  • Open Access
2 Citations
3,474 Views
12 Pages

Shoulder Magnetic Resonance Arthrography with the Internal and External Rotation Positions of the Humeral Head in the Evaluation of SLAP Lesions

  • Marco Porta,
  • Serena Capelli,
  • Anna Caroli,
  • Maurizio Balbi and ,
  • Alessandra Surace,
  • Francesca Serpi,
  • Eugenio Annibale Genovese,
  • Domenico Albano,
  • Luca Maria Sconfienza and
  • Alberto Aliprandi
  • + 6 authors+ 1 author

15 September 2022

We aimed to evaluate the diagnostic performance of shoulder MR arthrography (MRA) acquired in the neutral (N), internal rotation (IR), and external rotation (ER) positions of the shoulder to detect SLAP lesions. Three observers evaluated 130 MRAs to...

(This article belongs to the Special Issue Advances in Diagnostic Medical Imaging)
  • Article
  • Open Access
2 Citations
3,559 Views
18 Pages

11 March 2025

Magnetic Resonance Angiography (MRA) is widely used for cerebrovascular assessment, with Time-of-Flight (TOF) MRA being a common non-contrast imaging technique. However, maximum intensity projection (MIP) images generated from TOF-MRA often include n...

(This article belongs to the Special Issue MR-Based Neuroimaging)
  • Article
  • Open Access
16 Citations
4,821 Views
16 Pages

22 February 2022

The segmentation algorithm of cerebrovascular magnetic resonance angiography (MRA) images based on deep learning plays an essential role in medical study. Traditional segmentation algorithms face poor segmentation results and poor connectivity when t...

(This article belongs to the Special Issue Advances in Deep Learning-Based Medical Image Analysis)
  • Interesting Images
  • Open Access
513 Views
3 Pages

Ejaculation-Triggered Reversible Cerebral Vasoconstriction Syndrome: A Case Report with Longitudinal Neuroimaging

  • Koji Hayashi,
  • Yoshihiro Ito,
  • Mamiko Sato,
  • Yuka Nakaya and ,
  • Toshiaki Takehara,
  • Asuka Suzuki,
  • Toyoaki Miura,
  • Kouji Hayashi and
  • Yasutaka Kobayashi
  • + 4 authors+ 0 author

A 40-year-old man presented with thunderclap headache (TCH) and vomiting post-masturbatory ejaculation. He reported a similar episode with posterior neck pain five days earlier after ejaculation. Unlike his migraine history, these headaches were unus...

(This article belongs to the Special Issue Advancing Diagnostics in Neuroimaging)
  • Article
  • Open Access
31 Citations
6,175 Views
14 Pages

Benefits of the Non-Steroidal Mineralocorticoid Receptor Antagonist Finerenone in Metabolic Syndrome-Related Heart Failure with Preserved Ejection Fraction

  • Ixchel Lima-Posada,
  • Yohan Stephan,
  • Matthieu Soulié,
  • Roberto Palacios-Ramirez and ,
  • Benjamin Bonnard,
  • Lionel Nicol,
  • Peter Kolkhof,
  • Frederic Jaisser and
  • Paul Mulder
  • + 4 authors+ 0 author

28 January 2023

The mineralocorticoid receptor (MR) plays an important role in the development of chronic kidney disease (CKD) and associated cardiovascular complications. Antagonizing the overactivation of the MR with MR antagonists (MRA) is a therapeutic option, b...

(This article belongs to the Special Issue New Paradigms in Aldosterone and Mineralocorticoid Receptor Pathophysiology)
  • Article
  • Open Access
2 Citations
2,336 Views
17 Pages

Automation in Middle- and Upper-Atmosphere LIDAR Operations: A Maximum Rayleigh Altitude Prediction System Based on Night Sky Imagery

  • Junfeng Wei,
  • Linmei Liu,
  • Xuewu Cheng,
  • Yi Fan and ,
  • Weiqiang Zhan,
  • Lifang Du,
  • Wei Xiong,
  • Zhaoxiang Lin and
  • Guotao Yang
  • + 4 authors+ 0 author

31 January 2024

A prediction system was developed to determine the maximum Rayleigh altitude (MRA) by improving the automated detection of LIDAR power-on conditions and adapting to advancements in middle- and upper-atmosphere LIDAR technology. The proposed system wa...

(This article belongs to the Section Atmospheric Remote Sensing)
  • Article
  • Open Access
9 Citations
2,810 Views
13 Pages

BOLD Cerebrovascular Reactivity and NOVA Quantitative MR Angiography in Adult Patients with Moyamoya Vasculopathy Undergoing Cerebral Bypass Surgery

  • Loris Garbani Nerini,
  • Jacopo Bellomo,
  • Lara Maria Höbner,
  • Vittorio Stumpo and ,
  • Elisa Colombo,
  • Christiaan Hendrik Bas van Niftrik,
  • Tilman Schubert,
  • Zsolt Kulcsár,
  • Susanne Wegener and
  • Giuseppe Esposito
  • + 9 authors+ 4 authors

Revascularization surgery for the symptomatic hemisphere with hemodynamic impairment is effective for Moyamoya vasculopathy patients. However, careful patient selection is crucial and ideally supported by advanced quantitative hemodynamic imaging. Re...

(This article belongs to the Special Issue The Latest Exploration of Cerebrovascular Diseases: From Preclinical Research to Treatment)
  • Article
  • Open Access
9 Citations
2,191 Views
14 Pages

25 September 2024

Magnetorheological fluids (MRFs) are functional fluids that exhibit rapid and reproducible rheological responses to external magnetic fields. An MRF has been utilized to develop a haptic device with precise haptic feedback for teleoperative surgical...

(This article belongs to the Special Issue Magnetorheological Materials and Application Systems)
  • Proceeding Paper
  • Open Access
11 Citations
4,387 Views
9 Pages

26 October 2023

This paper presents the sensorless speed control of induction motors using a Model Reference Adaptive System (MRAS) method and field-oriented control. The main objective is to minimize the cost related to speed sensors, thereby improving both the aff...

(This article belongs to the Proceedings of The 4th International Electronic Conference on Applied Sciences)
  • Article
  • Open Access
27 Citations
13,573 Views
13 Pages

21 December 2017

The non-revenue water (NRW) ratio in water distribution networks is the ratio of losses from unbilled authorized consumption and apparent and real losses to the total water supply. NRW is an important parameter for prioritizing the improvement of a w...

(This article belongs to the Special Issue Advances in Water Distribution Networks)
  • Review
  • Open Access
23 Citations
7,576 Views
10 Pages

29 September 2023

Nonsteroidal mineralocorticoid receptor antagonists (MRAs) present a promising therapeutic option in cardiorenal diseases, mitigating the limitations of steroidal MRAs. Finerenone, a third-generation nonsteroidal MRA, has demonstrated beneficial effe...

(This article belongs to the Section Nephrology & Urology)
  • Article
  • Open Access
19 Citations
3,047 Views
27 Pages

MRA-YOLOv8: A Network Enhancing Feature Extraction Ability for Photovoltaic Cell Defects

  • Nannan Wang,
  • Siqi Huang,
  • Xiangpeng Liu,
  • Zhining Wang and ,
  • Yi Liu and
  • Zhe Gao
  • + 1 author+ 0 author

2 March 2025

To address the challenges posed by complex backgrounds and the low occurrence in photovoltaic cell images captured by industrial sensors, we propose a novel defect detection method: MRA-YOLOv8. First, a multi-branch coordinate attention network (MBCA...

(This article belongs to the Section Industrial Sensors)
  • Article
  • Open Access
64 Citations
9,522 Views
34 Pages

28 May 2015

Component substitution (CS) and multi-resolution analysis (MRA) are the two basic categories in the extended general image fusion (EGIF) framework for fusing panchromatic (Pan) and multispectral (MS) images. Despite of the method diversity, there are...

  • Article
  • Open Access
3 Citations
1,291 Views
19 Pages

17 November 2025

Rapid and reliable identification of large vessel occlusions and critical stenoses is essential for guiding treatment in acute ischemic stroke. Conventional MR angiography (MRA) and PET protocols are constrained by trade-offs among acquisition time,...

(This article belongs to the Special Issue Advances in Machine Learning and Data Mining: Emerging Trends and Applications)
  • Article
  • Open Access
32 Citations
7,310 Views
12 Pages

Rough Set Theory for Real Estate Appraisals: An Application to Directional District of Naples

  • Vincenzo Del Giudice,
  • Pierfrancesco De Paola and
  • Giovanni Battista Cantisani

8 February 2017

This paper proposes an application of Rough Set Theory (RST) to the real estate field, in order to highlight its operational potentialities for mass appraisal purposes. RST allows one to solve the appraisal of real estate units regardless of the dete...

(This article belongs to the Special Issue Real Estate Economics, Management and Investments)
  • Article
  • Open Access
55 Citations
9,008 Views
20 Pages

23 October 2017

In this work, the bands of a Sentinel-2A image with spatial resolutions of 20 m and 60 m are sharpened to a spatial resolution of 10 m to obtain visible and near-infrared (VNIR) and shortwave infrared (SWIR) spectral bands with a spatial resolution o...

  • Article
  • Open Access
29 Citations
5,237 Views
29 Pages

17 March 2022

Future wireless networks promise immense increases on data rate and energy efficiency while overcoming the difficulties of charging the wireless stations or devices in the Internet of Things (IoT) with the capability of simultaneous wireless informat...

(This article belongs to the Section Intelligent Sensors)
  • Systematic Review
  • Open Access
19 Citations
5,061 Views
8 Pages

Effectiveness of Cell-Free and Concentrated Ascites Reinfusion Therapy in the Treatment of Malignancy-Related Ascites: A Systematic Review and Meta-Analysis

  • Hao Chen,
  • Masashi Ishihara,
  • Nobuyuki Horita,
  • Shigeru Tanzawa and ,
  • Hiroki Kazahari,
  • Ryusuke Ochiai,
  • Takahiko Sakamoto,
  • Takeshi Honda,
  • Yasuko Ichikawa and
  • Nobuhiko Seki
  • + 6 authors+ 1 author

29 September 2021

Background: Malignancy-related ascites (MRA) is one of the symptoms causing discomfort in advanced cancer patients. Cell-free and concentrated ascites reinfusion therapy (CART) is one of the palliative treatments widely conducted in Japan only. Metho...

(This article belongs to the Section Systematic Review or Meta-Analysis in Cancer Research)
  • Article
  • Open Access
3 Citations
1,793 Views
41 Pages

Modulated twelve-voltage-vector model predictive current control (MPCC), which applies two or three voltage vectors per control period, exhibits superior steady-state performance compared to modulated six-active-voltage-vector MPCC and conventional M...

(This article belongs to the Special Issue New Trends in Electrical Drives for EV Applications)
  • Article
  • Open Access
78 Views
19 Pages

Machine-Learning-Assisted Detection of Residual or Recurrent Filling in Endovascularly Treated Intracranial Aneurysms on TOF-MRA: A Pilot Study

  • Sushmitha Puttappa Shivagange,
  • Augusto da Mota Goncalves Filho,
  • Mohamed S. Hefny and
  • Eduardo Portela de Oliveira

11 November 2026

Background and Purpose: Surveillance TOF-MRA is a non-invasive alternative to digital subtraction angiography (DSA) for detecting aneurysm residual/recurrence after endovascular embolization but is limited by coil/WEB device-related susceptibility ar...

(This article belongs to the Special Issue 4th Edition: AI/ML-Based Medical Image Processing and Analysis)
  • Article
  • Open Access
2 Citations
2,474 Views
19 Pages

Sensorless Control Strategy of Novel Axially Magnetized Vernier Permanent-Magnet Machine

  • Bowen Xu,
  • Jien Ma,
  • Qiyi Wu,
  • Lin Qiu and ,
  • Xing Liu,
  • Chao Luo and
  • Youtong Fang
  • + 2 authors+ 0 author

28 July 2022

Vernier permanent-magnet machines have been attracted more and more attention because of their high torque density. In this paper, the sensorless control strategy of the novel axially magnetized Vernier permanent-magnet (AMVPM) machine is presented....

(This article belongs to the Topic Advanced Electrical Machines and Drives Technologies)

of 4