Skip to Content

69 Results Found

  • Article
  • Open Access
1 Citations
1,037 Views
28 Pages

24 November 2025

The Korean Highway Bridge Design Code introduced requirements for sufficient tensile lap-splice lengths in 2005. Bridge piers designed before 2005 might not have enough tensile lap-splice length. In addition to that, old structures are susceptible to...

(This article belongs to the Section Construction and Building Materials)
  • Article
  • Open Access
1 Citations
5,454 Views
13 Pages

Reinforced concrete (RC) columns with short lap splices built in the early 1970s or before are known to have deficient seismic strength and ductility. These short lap splices are poorly confined and located right above the foundation level, where it...

  • Article
  • Open Access
19 Citations
8,547 Views
20 Pages

13 June 2020

The cyclic performance of non-seismically designed reinforced concrete (RC) columns, strengthened with carbon fiber reinforced polymer (CFRP) jackets, was analytically and experimentally investigated herein. Three cantilever column specimens were con...

(This article belongs to the Special Issue Experimental and Numerical Advancements on Strengthening of Concrete Structures with Fiber Reinforced Polymers)
  • Article
  • Open Access
6 Citations
2,343 Views
21 Pages

24 July 2024

The bond strength of tension lap splices in recycled-coarse-aggregate-reinforced concrete strengthened with hybrid (steel–polyolefin) fibers was experimentally investigated. This study was conducted with the help of twelve lap-spliced beam spec...

  • Article
  • Open Access
13 Citations
4,429 Views
23 Pages

Micro-Scale Experimental Approach for the Seismic Performance Evaluation of RC Frames with Improper Lap Splices

  • Ali Javed,
  • Chaitanya Krishna,
  • Khawaja Ali,
  • Muhammad Faheem Ud Din Afzal and ,
  • Armin Mehrabi and
  • Kimiro Meguro
  • + 1 author+ 0 author

Reinforced concrete (RC) frames are an integral part of modern construction as they resist both gravity and lateral loads in beams and columns. However, the construction methodologies of RC frames are vulnerable to non-engineering defects, particular...

(This article belongs to the Special Issue Structural Health Monitoring and Performance Evaluation of Bridges and Structural Elements)
  • Article
  • Open Access
1 Citations
2,178 Views
17 Pages

Effect of Macro Polyolefin Fibers on Bond Strength of Tension Lap Splices in RC Beams

  • Abdullah Al-Hussein,
  • Fareed H. Majeed and
  • Abdulnasser M. Abbas

30 September 2023

The effect of macro synthetic polyolefin fibers on the bond strength of tension lap splices in reinforced concrete (RC) beams is investigated in this study. The bond between the reinforcement and concrete plays a vital role in the strength of RC beam...

(This article belongs to the Section A. Building Structures)
  • Article
  • Open Access
2,103 Views
24 Pages

Reinforced concrete columns constructed prior to the 1970s often exhibit deficient lap splices at the base, characterized by insufficient splice lengths. In response to the urgent need for an efficient seismic assessment of these vulnerable structura...

(This article belongs to the Special Issue Sustainability in Building Structures: Optimization, Strengthening and Rehabilitation)
  • Article
  • Open Access
22 Citations
5,635 Views
22 Pages

14 December 2022

This paper examines analytically the design criteria for the composite retrofit of reinforced concrete (RC) columns with a short lap splice length of steel rebars inside the critical region. The advanced potential of pseudo-dynamic three-dimensional...

(This article belongs to the Collection Feature Papers in Fibers)
  • Article
  • Open Access
12 Citations
5,119 Views
15 Pages

Local Behavior of Lap-Spliced Deformed Rebars in Reinforced Concrete Beams

  • Agha Syed Muhammad Gillani,
  • Seung-Geon Lee,
  • Soo-Hyung Lee,
  • Hyerin Lee and
  • Kee-Jeung Hong

25 November 2021

Twelve full-scale reinforced concrete beams with two tension lap splices were constructed and tested under a four-point loading test. Half of these beams had shorter lap splices than that recommended by American Concrete Institute Building Code ACI 3...

(This article belongs to the Special Issue Performance and Applications of Construction Materials and Structures)
  • Article
  • Open Access
10 Citations
4,161 Views
21 Pages

17 June 2021

Construction with precast or prefabricated elements requires the connecting of structural joints. This study presents an accelerated construction method to strengthen reinforced concrete (RC) slab-type elements in flexure using precast lap-spliced te...

(This article belongs to the Section Construction and Building Materials)
  • Article
  • Open Access
9 Citations
3,962 Views
20 Pages

17 August 2022

In this paper, 3D finite element simulations were conducted for lap-spliced ultra-high-performance concrete (UHPC) beams using ABAQUS software. Based on the concrete damaged plasticity (CDP) model, the plastic damage factor was introduced to simulate...

(This article belongs to the Special Issue Reinforced Concrete Buildings)
  • Article
  • Open Access
17 Citations
3,577 Views
25 Pages

24 May 2022

In this paper, the structural performance of lap-spliced beams were investigated by the testing of 18-UHPFRC beams with and without a lap-spliced region and steel fiber. All test specimens were subjected to flexural load by using the four-point bendi...

(This article belongs to the Section Polymer Analysis and Characterization)
  • Article
  • Open Access
4 Citations
3,153 Views
20 Pages

6 March 2023

The precast concrete structure has the advantage of a short construction period, less labor consumption, and less pollution. The lapped-rebar splice is a type of connection for assembled reinforced concrete shear walls in the precast concrete structu...

(This article belongs to the Topic Microstructure and Properties in Metals and Alloys)
  • Article
  • Open Access
10 Citations
3,062 Views
14 Pages

9 November 2020

The present research investigated the bond behavior of a cleaned corroded reinforcing bar repaired with a partial depth concrete repair and a partial depth concrete repair followed by the application of fiber-reinforced polymer (FRP) sheets. Twelve l...

(This article belongs to the Special Issue Properties and Performance of Concrete Materials and Structures)
  • Article
  • Open Access
30 Citations
5,183 Views
29 Pages

9 May 2019

The tensile behaviors of textile-reinforced mortar (TRM) composites made with carbon fiber textile and alumina cement-based mortar were investigated through direct tensile tests. Three different surface treatment details in the lap splice area were u...

  • Article
  • Open Access
2 Citations
2,323 Views
15 Pages

25 May 2023

To investigate the mechanical properties of high-strength stainless steel wire mesh (HSSSWM) in Engineering Cementitious Composites (ECCs) and determine a reasonable lap length, a total of 39 specimens in 13 sets were designed and fabricated by consi...

(This article belongs to the Special Issue Numerical Modeling and Mechanical Properties of Fiber-Reinforced Cementitious Composites)
  • Article
  • Open Access
1 Citations
4,006 Views
13 Pages

Corrosion Effects on Bond Degradation and Cracking Patterns in Lapped Spliced Joints of Reinforced Concrete

  • Amged O. Abdelatif,
  • Sara E. Onsa,
  • Aya E. Ahmed,
  • Eiman A. Abdelraouf and ,
  • Razan M. Abdalgader,
  • Mohamed I. Ibrahim and
  • Joško Ožbolt
  • + 2 authors+ 0 author

This research study aims to enhance the understanding of corrosion behaviour in lapped spliced joints within reinforced concrete structures. Specifically, the effect of corrosion on bond degradation and crack formation is investigated. Accelerated co...

  • Article
  • Open Access
1,170 Views
20 Pages

4 February 2026

In this paper, the bond performance of tensile lap-spliced Glass and Basalt Fiber-Reinforced Polymer bars is investigated in high-strength concrete. Eighteen large-scale GFRP-reinforced concrete beams were fabricated and subjected to four-point loadi...

(This article belongs to the Special Issue Advanced Composite Carbon Fibers)
  • Article
  • Open Access
10 Citations
4,429 Views
18 Pages

31 July 2019

In the present study, the effect of harsh conditions on the tensile behavior of lap-spliced carbon fiber textile-reinforced mortar (TRM) with different surface treatment methods was investigated through the direct tensile test. The TRM coupons were e...

(This article belongs to the Special Issue Structural Performances of Concrete Composite Members: Experimental, Theoretical, Numerical Approaches)
  • Article
  • Open Access
175 Views
27 Pages

Cyclic Behavior of Reinforced Concrete Shear Walls with Welded Wire Mesh Stirrups and Lap-Spliced Boundary Reinforcement

  • Ming Xu,
  • Guoqi Zhang,
  • Bing Han,
  • Lu Lei and ,
  • Lei Ming and
  • Tianxiang Xie
  • + 1 author+ 0 author

19 October 2026

Factory-produced welded wire mesh stirrups offer a promising industrialized alternative to conventional transverse reinforcement in reinforced concrete shear walls. However, their seismic performance in combination with lap-spliced boundary longitudi...

(This article belongs to the Special Issue Mechanical Properties and Durability of Concrete Materials and Structures)
  • Article
  • Open Access
899 Views
21 Pages

Experimental Investigation of Concrete Beams with Novel Parallel-Lap Reinforcement Under Flexure

  • Hong Zhang,
  • Hehui Zheng,
  • Linsong Chen,
  • Feng Zhang and ,
  • Jie Liu and
  • Huiping Huang
  • + 1 author+ 0 author

To address the technical challenges associated with complex connection configurations and excessively long lap zones in the industrialized and prefabricated construction of reinforcements, this study proposes a novel parallel-lap splice that incorpor...

(This article belongs to the Special Issue Advances in Mechanical Behavior of Prefabricated Structures)
  • Article
  • Open Access
12 Citations
4,651 Views
21 Pages

Mechanical Analysis of Grouted Sleeve Lapping Connector

  • Qiong Yu,
  • Jiaqiu Sun,
  • Zhiyuan Xu,
  • Lingzhi Li and ,
  • Zhi Zhang and
  • Shaole Yu
  • + 1 author+ 0 author

14 November 2019

Compared to grouted splice connectors that have been widely used in constructing precast concrete structures, grouted sleeve lapping connectors have the advantages of a large sleeve interior diameter and low manufacturing cost. In this study, 16 grou...

(This article belongs to the Section Civil Engineering)
  • Review
  • Open Access
10 Citations
11,302 Views
23 Pages

Techniques Used for Bond Strengthening of Sub-Standard Splices in Concrete: A Review Study

  • Sabry Fayed,
  • Walid Mansour,
  • Taher A. Tawfik,
  • Peter Sabol and
  • Dušan Katunský

5 April 2023

Bar splicing is considered an essential part of the construction process of reinforced concrete (RC) due to the ease of installation in construction, transportation constraints, and restricted length of reinforcing bars. Splices serve the primary rol...

(This article belongs to the Special Issue Mechanical Behavior and Degradation Processes of Advanced Materials)
  • Article
  • Open Access
4 Citations
2,337 Views
24 Pages

The connection zones between precast concrete composite slabs and composite walls commonly experience severe reinforcement conflicts due to protruding rebars, significantly reducing construction efficiency. To address this, a novel slotted concrete c...

(This article belongs to the Section A. Building Structures)
  • Article
  • Open Access
1 Citations
4,981 Views
11 Pages

The results of an experimental investigation carried out on steel splices bonded by (Carbon-Fiber–Reinforced Polymers) C-FRPs are presented in this paper. The main aim of the study is to examine the influence of different parameters on the type of fa...

(This article belongs to the Section Construction Technologies)
  • Article
  • Open Access
19 Citations
8,856 Views
24 Pages

7 September 2023

While various approaches have been developed to minimize rebar cutting waste, such as optimizing cutting patterns and the lap splice position, reducing rebar usage by minimizing the number of splices remains uninvestigated. In response to these issue...

(This article belongs to the Topic Pathways to Sustainable Construction: Innovations in New Materials, Construction Techniques, and Management Practices)
  • Article
  • Open Access
6 Citations
4,387 Views
18 Pages

16 March 2021

When a seismic force acts on bridges, the pier can be damaged by the horizontal inertia force of the superstructure. To prevent this failure, criteria for seismic reinforcement details have been developed in many design codes. However, in moderate se...

(This article belongs to the Special Issue Buildings and Structures under Extreme Loads II)
  • Article
  • Open Access
12 Citations
5,477 Views
24 Pages

3 May 2021

The existing non-ductile RC structures built prior to the 1960s–1970s were mainly conceived to carry only vertical loads. As a result, the columns of these structures demonstrate poor overall hysteresis behavior during strong earthquakes, dominated b...

(This article belongs to the Special Issue Fiber-Reinforced Polymers and Fiber-Reinforced Cement Composites as Concrete Reinforcement)
  • Article
  • Open Access
22 Citations
4,573 Views
31 Pages

Four exterior reinforced concrete beam–column joint subassemblages with poor reinforcement details and low-quality materials were constructed and subjected to cyclic lateral deformations under constant axial loading of the columns. The longitud...

(This article belongs to the Section B. Building Materials, and Repair & Renovation)
  • Article
  • Open Access
383 Views
31 Pages

Flexural Performance of Deficient RC Beams Repaired with GFRP Composite

  • Zena Aljazaeri,
  • Hayder Alghazali,
  • Zuhair Al-Jaberi and
  • John J. Myers

Fiber-reinforced polymer composite materials have been improved for use in repairing and strengthening existing infrastructure over the past few decades. This case study focuses on the effect of confinement with GFRP strips on the structural performa...

(This article belongs to the Special Issue Structural Health Monitoring, Evaluation and Strengthening of Concrete Structures)
  • Article
  • Open Access
8 Citations
2,768 Views
16 Pages

13 April 2022

This paper presents a new textile-reinforced concrete (TRC) installation method for strengthening structurally deficient or damaged reinforced concrete (RC) structures with grouting. In this study, cementitious grout was used as a matrix for the TRC...

  • Article
  • Open Access
530 Views
20 Pages

Experimental Study on the Seismic Performance of Assembled Shear Walls Based on UHPC Connections

  • Gang Chen,
  • Shiwei Yuan,
  • Qizhen Zheng,
  • Libo Long and ,
  • Huiyan Li and
  • Decai Nong
  • + 1 author+ 0 author

This paper investigates the seismic performance of precast concrete shear-wall subassemblies connected by post-cast ultra-high performance concrete (UHPC) zones and short lap-spliced reinforcement with a lap length of 10d, where d denotes the diamete...

(This article belongs to the Special Issue High- and Ultra-High Performance Concrete: Properties, Developments and Applications)
  • Article
  • Open Access
4 Citations
1,160 Views
18 Pages

Using Near-Surface-Mounted Small-Diameter Steel Wires to Improve Construction Efficiency in Strengthening Substandard Lapped Spliced Reinforced Concrete Beams

  • Sabry Fayed,
  • Mohamed Ghalla,
  • Ehab A. Mlybari,
  • Rabeea W. Bazuhair and ,
  • Emrah Madenci and
  • Yasin Onuralp Özkılıç
  • + 1 author+ 0 author

Strengthening lapped spliced reinforced concrete (RC) beams using tiny-diameter steel wires as near-surface-mounted (NSM) rods has not been carried out previously. Thus, the purpose of this work is to examine the behavior of RC beams with insufficien...

(This article belongs to the Section A. Building Structures)
  • Article
  • Open Access
6 Citations
1,790 Views
23 Pages

30 August 2024

CSMSFC (Calcium Sulphoaluminate Cement-based Micro Steel Fiber Concrete) possesses the advantages of early strength, high strength, exceptional toughness, minimal shrinkage, and excellent bond performance with bars. When applied to NLSB (Non-contact...

(This article belongs to the Section C. Building Energy, Physics, Environment, and Systems)
  • Article
  • Open Access
7 Citations
5,551 Views
22 Pages

Flexural Behavior of RC Beams with an Abrupt Change in Depth: Experimental Work

  • Sabry Fayed,
  • Emrah Madenci and
  • Yasin Onuralp Özkılıç

8 December 2022

The most crucial components in the case of roofs with two levels or a variable floor height are variable depth beams. In order to investigate the flexural behavior of reinforced concrete (RC) beams with varying depths under static loads, experimental...

(This article belongs to the Special Issue New and Future Progress for Concrete Structures)
  • Article
  • Open Access
1,230 Views
20 Pages

25 December 2025

To study the effects of different spliced forms and spliced lengths on the flexural performance of traditional spliced timber columns, four-point bending tests were conducted. A total of 14 specimens were designed across three groups, including one g...

(This article belongs to the Section A. Building Structures)
  • Article
  • Open Access
3 Citations
3,507 Views
22 Pages

31 January 2025

The growing demand for reinforced concrete (RC) structures, driven by population growth, significantly contributes to carbon emissions, particularly during the construction phase. Steel rebar production, a major contributor to these emissions, faces...

(This article belongs to the Special Issue Sustainable Civil Engineering: Innovative Methods for Structures, Elements and Materials)
  • Article
  • Open Access
13 Citations
3,929 Views
17 Pages

16 September 2020

During the restoration of ancient wood structures, the original material of the structures should be kept as much as possible, so a spliced method by using lap joints is commonly used to repair ancient wood structures. This study studies the mechanic...

  • Article
  • Open Access
2 Citations
2,108 Views
20 Pages

27 August 2024

The mortise-and-tenon joint prefabricated connection combines the assembly form of mortise-and-tenon joints and cast-in-place wet joints. It achieves reliable joint connections through small joint depths and lap-spliced reinforcement lengths. To stud...

(This article belongs to the Topic Resilient Civil Infrastructure)
  • Article
  • Open Access
27 Citations
4,614 Views
24 Pages

6 September 2021

This study develops three-dimensional (3D) finite element (FE) models of composite retrofits in deficient reinforced concrete (RC) columns and frames. The aim is to investigate critical cases of RC columns with inadequate lap splices of bars or corro...

  • Article
  • Open Access
19 Citations
10,218 Views
19 Pages

A Fiber Optic Doppler Sensor and Its Application in Debonding Detection for Composite Structures

  • Fucai Li,
  • Hideaki Murayama,
  • Kazuro Kageyama,
  • Guang Meng and ,
  • Isamu Ohsawa and
  • Takehiro Shirai
  • + 1 author+ 0 author

14 June 2010

Debonding is one of the most important damage forms in fiber-reinforced composite structures. This work was devoted to the debonding damage detection of lap splice joints in carbon fiber reinforced plastic (CFRP) structures, which is based on guided...

(This article belongs to the Special Issue Intelligent Sensors - 2010)
  • Article
  • Open Access
3 Citations
7,906 Views
20 Pages

Special Length Priority Optimization Model: Minimizing Wall Rebar Usage and Cutting Waste

  • Dong-Jin Kim,
  • Lwun Poe Khant,
  • Daniel Darma Widjaja and
  • Sunkuk Kim

21 January 2024

The production of steel rebar is an energy-intensive process that generates CO2 emissions. In construction, waste is generated by cutting stock-length rebar to the required lengths. The reduction rate achieved in most previous studies was limited due...

(This article belongs to the Special Issue Artificial Intelligence and Optimization Methods in Construction Industry)
  • Article
  • Open Access
6 Citations
5,400 Views
22 Pages

10 May 2024

Lap splices are the most commonly used method worldwide because they do not require specific equipment or skilled workers. However, lap splices incur high construction costs because of the long splice lengths required for large-diameter rebars in meg...

(This article belongs to the Section Sustainable Engineering and Science)
  • Article
  • Open Access
7 Citations
6,384 Views
26 Pages

20 January 2024

The construction of reinforced concrete (RC) structures inevitably consumes an excessive number of rebars, leading to significant cutting waste and carbon emissions. Extensive research has been conducted to minimize this issue and its consequences; h...

(This article belongs to the Section E. Construction Management, and Computers & Digitization)
  • Article
  • Open Access
1 Citations
776 Views
29 Pages

Mechanical Behavior of Grouted Sleeve Butt and Lap Joints with Anti-Deflection Measures Under Uniaxial Tension and High-Stress Cyclic Loading

  • Qiong Yu,
  • Zuorui Wen,
  • Ziming Tang,
  • Hua Wei and ,
  • Fangjun Zheng,
  • Zhi Zhang,
  • Zhenhai Chen and
  • Jiaqiu Sun
  • + 3 authors+ 0 author

23 February 2026

To compare the mechanical performance differences between sleeve grouting lap and butt joints, a total of 41 lap joints, including 27 standard lap joints and 14 anti-deflection lap joints, and 20 butt joints were subjected to tensile and high-stress...

(This article belongs to the Section Civil Engineering)
  • Article
  • Open Access
4 Citations
3,942 Views
18 Pages

Flexural Performance of Splice Connections in Cross-Laminated Timber

  • Mahbube Subhani,
  • Sukanta Kumer Shill,
  • Safat Al-Deen,
  • Mohammad Anwar-Us-Saadat and
  • Mahmud Ashraf

This study demonstrates the moment resistance performance of various splice connections of cross-laminated timber (CLT) subjected to flatwise bending. A total of 33 samples in two groups (half-lapped and single-splined) were tested under four-point b...

(This article belongs to the Section A. Building Structures)
  • Article
  • Open Access
3 Citations
4,142 Views
23 Pages

Effectiveness of UHPC Jackets in Pier Retrofitting for Lateral Load Resistance

  • Zoi G. Ralli,
  • Roberto Salazar Gonzalez and
  • Stavroula J. Pantazopoulou

9 December 2024

Ultra-high-performance concrete (UHPC) is a recently emerged material with exceptional durability and ductility. While widely used in bridge retrofitting, particularly to replace expansion joints and deck overlays, UHPC has seen limited use in jacket...

  • Article
  • Open Access
5 Citations
1,922 Views
19 Pages

Experimental and Numerical Research on the Mechanical Properties of a Novel Prefabricated Diaphragm Wall–Beam Joint

  • Yang Liu,
  • Guisheng Yang,
  • Chunyu Qi,
  • Peng Zhang and ,
  • Tao Cui and
  • Ran Song
  • + 1 author+ 0 author

Based on the engineering context of prefabricated underground station structures, this paper proposed a novel diaphragm wall–beam joint based on post-poured ultra-high-performance concrete (UHPC) and non-contact lap-spliced steel bars. This res...

(This article belongs to the Special Issue Advances in Modern Structural Engineering: From Materials to Building Structures)
  • Article
  • Open Access
93 Citations
7,335 Views
13 Pages

11 May 2022

The performance of both non-spliced and spliced steel bars significantly affects the overall performance of structural reinforced concrete elements. In this context, the mechanical properties of reinforcement bars (i.e., their ultimate strength and s...

(This article belongs to the Section Civil Engineering)
  • Article
  • Open Access
13 Citations
5,444 Views
26 Pages

31 January 2024

The construction industry generates significant CO2 emissions and reinforcing bars (rebar), which are a major contributor to this environmental impact. Extensive research has been conducted to address this particular issue. Recent research advances h...

(This article belongs to the Section Sustainable Engineering and Science)

of 2