Skip to Content
You are currently on the new version of our website. Access the old version .

150 Results Found

  • Article
  • Open Access
3 Citations
2,190 Views
24 Pages

28 August 2025

In the vector control of permanent magnet synchronous motor (PMSM), non-periodic disturbances such as cross-coupling between axes and variations in electrical parameters, along with periodic harmonic disturbances caused by inverter nonlinearities and...

  • Article
  • Open Access
20 Citations
3,494 Views
21 Pages

2 March 2020

In the permanent magnet direct-drive wind power grid-connected system, in order to solve the coupling problem between d -axis and q -axis currents and to improve the disturbance rejection performance of direct current (DC) bus voltage under...

(This article belongs to the Special Issue Control Schemes for Wind Electricity Systems)
  • Article
  • Open Access
6 Citations
4,122 Views
17 Pages

An interior permanent magnet synchronous motor (IPMSM) is a kind of drive motor with high power density that is suitable for electric vehicles. In this paper, the dq-axis current reaction time of IPMSM was investigated in order to improve the reactio...

(This article belongs to the Special Issue Temperature Field, Electromagnetic Field, and Operation Control of Permanent Magnet Motor for Electric Vehicles)
  • Article
  • Open Access
334 Views
20 Pages

25 June 2026

To reduce the direct-current (DC)-side inductances of single-phase current-source pulse-width-modulation (PWM) rectifiers while improving their power densities. This paper introduces a symmetric half-bridge power decoupling circuit topology. First, t...

(This article belongs to the Section Electrical Machines and Drives)
  • Article
  • Open Access
5 Citations
5,845 Views
14 Pages

6 December 2017

With the rapid development of renewable energy generation, single-phase grid-connected inverters have been widely applied in modern power systems. Since the power output of the renewable sources is continuously changing, independent active/reactive p...

(This article belongs to the Special Issue Emerging Power Electronics Technologies for Power Systems and Machine Drives)
  • Article
  • Open Access
7 Citations
2,437 Views
24 Pages

Multivariable Control-Based dq Decoupling in Voltage and Current Control Loops for Enhanced Transient Response and Power Delivery in Microgrids

  • Mandarapu Srikanth,
  • Yellapragada Venkata Pavan Kumar,
  • Challa Pradeep Reddy and
  • Rammohan Mallipeddi

26 July 2024

Being multivariable in nature, voltage and current control loops have controllers in the forward and cross-coupling paths. Most methods discussed in the literature focus on tuning the controllers in the forward paths to reduce the dq coupling. A modi...

(This article belongs to the Special Issue Power Quality and Hosting Capacity in the Microgrids)
  • Article
  • Open Access
6 Citations
3,135 Views
17 Pages

An Accurate Discrete Current Controller for High-Speed PMSMs/Gs in Flywheel Applications

  • Xiang Zhang,
  • Yunlong Chen,
  • Yves Mollet,
  • Jiaqiang Yang and
  • Johan Gyselinck

20 March 2020

High-speed Permanent-Magnet Synchronous Motors/Generators (PMSMs/Gs) in a Flywheel Energy Storage System (FESS) are faced with high cross-coupling voltages and low switching-to-fundamental frequency ratios. High cross-coupling voltages between d-q ax...

(This article belongs to the Special Issue Flywheel Energy Storage Systems and Applications)
  • Article
  • Open Access
294 Views
21 Pages

Singular Value-Based Analysis of Current Decoupling Control Effect of Permanent Magnet Synchronous Motors

  • Tianyi Zhang,
  • Qi Li,
  • Pengbin Xu,
  • Dafang Wang and ,
  • Haoyu Zhou and
  • Jinhuan Zhao
  • + 1 author+ 0 author

7 September 2026

The dq-axis coupling effect significantly influences the vector control performance of permanent magnet synchronous motors (PMSMs), and traditional proportional-integral (PI) control cannot control the system as desired. Extensive studies have addres...

(This article belongs to the Special Issue Advanced Control and Fault Diagnosis in Electrical Drives)
  • Article
  • Open Access
1 Citations
2,022 Views
15 Pages

A Critical Analysis and Comparison of the Effect of Source Inductance on 3- and 4-Lead SuperJunction MOSFETs Turn-Off

  • Santi Agatino Rizzo,
  • Nunzio Salerno,
  • Cristina Ventura,
  • Alfio Scuto and
  • Giuseppe Sorrentino

15 October 2024

This paper critically compares the turn-off performance of two package solutions, 3-lead (3L) vs. 4-lead (4L), in SuperJunction MOSFETs. It is commonly assumed that the better performance (lower switching losses) of the 4L MOSFET is obtained thanks t...

(This article belongs to the Special Issue Power Electronics in Italy—Emerging Electronic Power Technologies and Electronic Devices in the Industrial 4.0 Era)
  • Article
  • Open Access
2 Citations
2,902 Views
18 Pages

Passivity-Based Control for Transient Power Sharing and State of Charge Restoration in a Semi-Active Supercapacitor-Battery System

  • Fabian Fracica-Rodriguez,
  • Manuel Acevedo-Iles,
  • David Romero-Quete,
  • Wilmar Martinez and
  • Camilo A. Cortes

12 September 2024

This paper presents a passivity-based control (PBC) approach integrated with filtering for a supercapacitor (SC) in a semi-active hybrid energy storage system. The PBC is designed as a current controller using the reference provided by the filter to...

(This article belongs to the Section Battery Modelling, Simulation, Management and Application)
  • Article
  • Open Access
2,785 Views
20 Pages

19 August 2023

The dq current transformation method can be used to achieve the drive control of the maglev permanent magnet synchronous linear motor (MPMSLM). Specifically, the control of the suspension force Fz can be achieved by controlling the d-axis current, an...

(This article belongs to the Special Issue Measurement Systems for Electric Machines and Motor Drives)
  • Article
  • Open Access
4 Citations
2,838 Views
25 Pages

14 February 2024

Vector control of an induction machine (IM) is typically performed by using cascade control structures with conventional linear proportional–integral (PI) controllers, the inner loop being designed for current control and the outer loop for rot...

(This article belongs to the Special Issue Advanced Control in Power Electronics, Drives and Generators)
  • Article
  • Open Access
323 Views
22 Pages

Fractional-Order Composite Control for Fractional-Order Modular Multilevel Converters

  • Yongzeng Xie,
  • Fei Lan,
  • Junhua Xu,
  • Yingheng Li and
  • Fulin Luo

The existing basic control system of fractional-order modular multilevel converters (FO-MMCs) is mainly designed for ideal operating conditions and exhibits limited adaptability under grid unbalanced conditions. To address this issue, this paper prop...

(This article belongs to the Topic Modeling, Stability, and Control of Dynamic Systems and Their Applications)
  • Article
  • Open Access
3 Citations
5,224 Views
19 Pages

Inverse-System Decoupling Control of DC/DC Converters

  • Yimin Lu,
  • Haimeng Zhu,
  • Xianfeng Huang and
  • Robert D. Lorenz

7 January 2019

Existing large-signal control schemes for DC/DC converters formulate control strategies based primarily on nonlinear control theory, and the associated design and implementation are relatively complex. In this work, a decomposition modeling and inver...

(This article belongs to the Section F: Electrical Engineering)
  • Article
  • Open Access
5 Citations
6,076 Views
18 Pages

Bridgeless PFC Converter without Electrolytic Capacitor Based on Power Decoupling

  • Ning-Zhi Jin,
  • Zhi-Qiang Wu,
  • Long Zhang,
  • Yu Feng and
  • Xiao-Gang Wu

Due to fewer conduction devices in operating condition, the bridgeless power factor correction (PFC) converter is more efficient than the traditional PFC circuit. However, to achieve a low output voltage ripple on the DC side, a large electrolytic ca...

(This article belongs to the Special Issue Energy Storage, Analysis and Battery Usage)
  • Article
  • Open Access
13 Citations
3,577 Views
19 Pages

27 June 2023

This paper presents a cascade predictive control structure based on field-oriented control (FOC) in the dq rotor reference frame for the synchronous reluctance machine (SynRM). The constant d-axis current control strategy was used, and thus, the elec...

(This article belongs to the Special Issue Synchronous Reluctance Motor-Drive Advancements)
  • Article
  • Open Access
3 Citations
2,134 Views
18 Pages

With the ongoing development of electronic power technologies, harmonic pollution in the power grid has become a topic of great concern. This study takes a substation as its background. The safe and steady operation of the station’s equipment w...

  • Article
  • Open Access
4 Citations
3,079 Views
23 Pages

12 August 2021

Voltage source converter (VSC) based HVDC systems are one of the most promising technologies for high voltage bulk power transmission. The reliability and stability of a VSC-based HVDC system greatly depends on the design of a proper controller for t...

  • Article
  • Open Access
1 Citations
452 Views
28 Pages

18 June 2026

Large-scale integration of renewable energy sources and power-electronic equipment introduces substantial background harmonics into the grid and, at the same time, gives rise to weak-grid operating conditions with a low short-circuit ratio, thereby d...

(This article belongs to the Collection Advanced Control and Applications of Power Electronics and Power Converters)
  • Article
  • Open Access
27 Citations
5,028 Views
19 Pages

PMSM Vector Control Strategy Based on Active Disturbance Rejection Controller

  • Kai Zhou,
  • Min Ai,
  • Yancheng Sun,
  • Xiaogang Wu and
  • Ran Li

10 October 2019

Based on current research into the vector control principles of the permanent magnet synchronous motor (PMSM), a control strategy founded upon an Active Disturbances Rejection Controller (ADRC) is proposed. This control strategy consists of an ADRC s...

  • Article
  • Open Access
1 Citations
2,042 Views
23 Pages

12 November 2024

In analyzing the decoupling of emissions from economic growth, current literature foregoes the nonlinear complexities of macroeconomic systems, leading to ineffective energy transition policies, specifically for developing countries. This study focus...

(This article belongs to the Section Power Electronics)
  • Article
  • Open Access
2 Citations
4,067 Views
20 Pages

In the present study, a novel multiple three-phase low-voltage and high-current permanent magnet synchronous generation system is proposed, which has only half-turn coils per phase. The proposed system is composed of a generator and two confluence pl...

(This article belongs to the Special Issue Power Converters in Power Electronics)
  • Article
  • Open Access
5 Citations
2,065 Views
25 Pages

Research on the Smooth Switching Control Strategy of Electric Vehicle Charging Stations Based on Photovoltaic–Storage–Charging Integration

  • Tao Wang,
  • Jinghao Ma,
  • Cunhao Lin,
  • Xin Li and ,
  • Shenhui Chen and
  • Jihui Zhang
  • + 1 author+ 0 author

To facilitate seamless transitions between grid-connected and islanded modes in PV–storage–charging integration, an energy storage system converter is designated as the subject of investigation, and its operational principles are examined...

(This article belongs to the Special Issue Intelligent Electric Vehicle Control, Testing and Evaluation)
  • Article
  • Open Access
10 Citations
4,004 Views
15 Pages

Decoupled Current Controller Based on Reduced Order Generalized Integrator for Three-Phase Grid-Connected VSCs in Distributed System

  • Sen Zhang,
  • Jianfeng Zhao,
  • Zhihong Zhao,
  • Kangli Liu and ,
  • Pengyu Wang and
  • Bin Yang
  • + 1 author+ 0 author

24 June 2019

Grid-connected voltage source converters (GC-VSCs) are used for interfacing the distributed power generation system (DPGS) to the utility grid. Performance of the current loop is a critical issue for these GC-VSCs. Recently, reduced order generalized...

(This article belongs to the Special Issue Design and Control of Power Converters 2019)
  • Article
  • Open Access
4 Citations
3,675 Views
14 Pages

23 January 2022

This paper presents a detailed analysis of dynamic properties and accuracy issues of the torque-producing stator current control loop for vector-controlled induction motor drives. In this paper, a necessary mathematical description of vector control...

(This article belongs to the Special Issue Applications of Modern Methods to Control of Electric Drives)
  • Article
  • Open Access
9 Citations
3,326 Views
25 Pages

A Novel Feedforward Scheme for Enhancing Dynamic Performance of Vector-Controlled Dual Active Bridge Converter with Dual Phase Shift Modulation for Fast Battery Charging Systems

  • Armel Asongu Nkembi,
  • Danilo Santoro,
  • Fawad Ahmad,
  • Iñigo Kortabarria and ,
  • Paolo Cova,
  • Emilio Sacchi and
  • Nicola Delmonte
  • + 2 authors+ 0 author

24 September 2024

This paper proposes a novel feedforward control scheme to achieve a very smooth transition from Constant Current (CC) to Constant Voltage (CV) charging modes, the commonly used method for electric vehicle charging applications. Furthermore, a three-l...

(This article belongs to the Special Issue Advanced DC-DC Converter Topology Design, Control, Application)
  • Article
  • Open Access
9 Citations
5,544 Views
16 Pages

18 September 2018

This paper presents the modeling and control-loop design method with an inverted decoupling scheme of a single-phase photovoltaic grid-connected five-level cascaded H-bridge multilevel inverter. For the unity power factor, the proportional and integr...

(This article belongs to the Special Issue Renewable Electric Energy Systems)
  • Article
  • Open Access
1,072 Views
19 Pages

Decoupling Control for the HVAC Port of Power Electronic Transformer

  • Wusong Wen,
  • Tianwen Zhan,
  • Yingchao Zhang and
  • Jintong Nie

4 August 2025

For the high-voltage AC port of power electronic transformer (HVAC-PET) with three-phase independent DC buses on the low-voltage side, a decoupling control strategy, concerning the influence of grid voltage imbalance, three-phase active-load imbalanc...

  • Article
  • Open Access
21 Citations
3,851 Views
16 Pages

Electromechanical Actuator Servo Control Technology Based on Active Disturbance Rejection Control

  • Qian Fang,
  • Yong Zhou,
  • Shangjun Ma,
  • Chao Zhang and ,
  • Ye Wang and
  • Haibin Huangfu
  • + 1 author+ 0 author

Electromechanical actuators (EMA) are becoming more and more widely used. As the core technology of EMA, servo control technology determines their performance. In this paper, an active disturbance rejection control (ADRC) method with an improved exte...

(This article belongs to the Section Systems & Control Engineering)
  • Article
  • Open Access
1 Citations
502 Views
27 Pages

25 June 2026

Voltage source converters (VSCs), together with their inner current and outer power/voltage control loops, are fundamental building blocks in the modern, converter-dominated power systems, particularly within high-voltage DC (HVDC) frameworks. Select...

(This article belongs to the Section F1: Electrical Power System)
  • Feature Paper
  • Article
  • Open Access
7 Citations
6,613 Views
20 Pages

9 April 2017

This paper presents the design and experimental voltage quality evaluation of controllers for the output voltages of 3-phase four-leg voltage source inverters. These inverters are needed in stand-alone power systems to supply linear and non-linear, b...

(This article belongs to the Special Issue Power Electronics in Power Quality)
  • Article
  • Open Access
17 Citations
4,611 Views
22 Pages

30 October 2020

This paper presents the power factor control of a permanent magnet synchronous wind generator (PMSG) wind turbine using a phase voltage-oriented control (PVOC) scheme, which is different from the conventional rotor flux-oriented control (RFOC) method...

(This article belongs to the Section I: Energy Fundamentals and Conversion)
  • Article
  • Open Access
10 Citations
6,254 Views
16 Pages

Maintenance Maneuver Automation for an Adapted Cylindrical Shape TEC

  • Rafael Morales,
  • Lorenzo Fernández,
  • Eva Segura and
  • José A. Somolinos

14 September 2016

Several manufacturers have developed devices with which to harness tidal/current power in areas where the depth does not exceed 40 m. These are the so-called first generation Tidal Energy Converters (TEC), and they are usually fixed to the seabed by...

(This article belongs to the Special Issue Numerical Modelling of Wave and Tidal Energy)
  • Article
  • Open Access
1 Citations
2,730 Views
17 Pages

Dynamic Decoupled Current Control for Smooth Torque of the Open-Winding Variable Flux Reluctance Motor Using Integrated Torque Harmonic Extended State Observer

  • El Moundher Aouiche,
  • Xu Liu,
  • Abdelaziz Aouiche,
  • Mustafa Alrayah Hassan and ,
  • Mohammed Echarif Aguida,
  • Junaid Ali Khan and
  • Yang Cao
  • + 2 authors+ 0 author

17 January 2025

Variable Flux Reluctance Machines (VFRMs) face multiple interconnected challenges that limit their performance, particularly in high-performance applications such as electric vehicles (EVs), where smooth torque output and robust operation are critica...

(This article belongs to the Special Issue Recent Advances in Sustainable Electrical Energy Technologies (2nd Edition))
  • Article
  • Open Access
5 Citations
3,865 Views
24 Pages

When three-phase voltages are polluted with unbalance, DC offsets, or higher harmonics, it is a challenge to quickly detect their parameters such as phases, frequency, and amplitudes. This paper proposes a phase-locked loop (PLL) for the three-phase...

(This article belongs to the Special Issue Grid-Connected and Isolated Renewable Energy Systems)
  • Article
  • Open Access
19 Citations
6,213 Views
16 Pages

17 August 2017

Dielectrophoresis is defined as the motion of an electrically polarisable particle in a non-uniform electric field. Current dielectrophoretic devices enabling sorting of cells are mostly controlled in open-loop applying a predefined voltage on micro-...

  • Article
  • Open Access
7 Citations
4,576 Views
17 Pages

An Optimal Power Control Strategy for Grid-Following Inverters in a Synchronous Frame

  • Juan F. Patarroyo-Montenegro,
  • Jesus D. Vasquez-Plaza,
  • Fabio Andrade and
  • Lingling Fan

25 September 2020

This work proposes a power control strategy based on the linear quadratic regulator with optimal reference tracking (LQR-ORT) for a three-phase inverter-based generator (IBG) using an LCL filter. The use of an LQR-ORT controller increases robustness...

(This article belongs to the Special Issue Fault Diagnosis and Control Design Applications of Energy Systems)
  • Article
  • Open Access
3 Citations
2,213 Views
19 Pages

The growing utilization of single-phase pulse width modulation (PWM) rectifiers in various applications has spurred interest in detecting and monitoring faults in these devices. In particular, voltage and current sensors play a crucial role in the co...

(This article belongs to the Special Issue Advanced Fault Detection, Diagnosis and Control in Industrial Electronics)
  • Article
  • Open Access
19 Citations
5,518 Views
20 Pages

2 April 2021

Aiming at the problem of power coupling and complicated decoupling in the d-q coordinate system of a three-phase grid-connected inverter, a current closed-loop control strategy based on an improved QPIR (quasi-proportional integral resonant) controll...

(This article belongs to the Special Issue Electric Power Applications)
  • Article
  • Open Access
3,398 Views
18 Pages

8 March 2019

To eliminate current harmonics and to obtain enhanced dynamic behaviors, the voltage feedforward scheme is normally adopted in the control process of transformerless grid-tied converters. However, voltage measurement errors caused by parameter variat...

  • Article
  • Open Access
318 Views
20 Pages

Linear Active Disturbance Rejection Control Strategy Based on Improved Quasi-Proportional Resonance for the Inner Current Loop of a Grid-Connected Inverter

  • Jinhao Shen,
  • Hua Zhang,
  • Xueneng Su,
  • Yiwen Gao and ,
  • Kun Zheng,
  • Cheng Long and
  • Xinbo Liu
  • + 2 authors+ 0 author

16 September 2026

Nonlinear and asymmetrical loads in microgrids cause severe current distortion and phase unbalance, presenting critical challenges for grid-connected energy storage inverters. Conventional dq-frame Linear Active Disturbance Rejection Control (LADRC)...

(This article belongs to the Section Electrical, Electronics and Communications Engineering)
  • Article
  • Open Access
1 Citations
2,481 Views
24 Pages

Adaptive Quasi-Super-Twisting Sliding Mode Control for Flexible Multistate Switch

  • Wenzhong Ma,
  • Xiao Wang,
  • Yusheng Wang,
  • Wenyan Zhang and ,
  • Hengshuo Li and
  • Yaheng Zhu
  • + 1 author+ 0 author

29 May 2024

The mathematical model of a flexible multistate switch (FMSS) exhibits nonlinear and strong coupling characteristics, whereas traditional power decoupling control makes it difficult to completely decouple the output power. The traditional proportiona...

(This article belongs to the Special Issue Advanced Power Electronics Technology)
  • Article
  • Open Access
7 Citations
4,057 Views
21 Pages

4 December 2021

An online parameter estimation methodology using the d-axis current injection, which can estimate the distorted voltage of the current-controlled voltage source inverter (CCVSI), the varying dq-axis inductances, and the rotor flux, is proposed in thi...

(This article belongs to the Topic Optimisation, Optimal Control and Nonlinear Dynamics in Electrical Power, Energy Storage and Renewable Energy Systems)
  • Article
  • Open Access
24 Citations
5,141 Views
19 Pages

15 September 2019

The implementation and experimental validation of current control strategy based on predictive control and equivalent input disturbance approach is discussed for permanent magnet synchronous motor (PMSM) control system in the paper. First, to realize...

(This article belongs to the Special Issue Advanced Control Systems for Electric Drives)
  • Article
  • Open Access
14 Citations
6,786 Views
39 Pages

A Path-Following Controller for Marine Vehicles Using a Two-Scale Inner-Outer Loop Approach

  • Pramod Maurya,
  • Helio Mitio Morishita,
  • Antonio Pascoal and
  • A. Pedro Aguiar

5 June 2022

This article addresses the problem of path following of marine vehicles along straight lines in the presence of currents by resorting to an inner-outer control loop strategy, with due account for the presence of currents. The inner-outer loop control...

(This article belongs to the Special Issue Motion Optimization and Control of Single and Multiple Autonomous Aerial, Land, and Marine Robots)
  • Proceeding Paper
  • Open Access
7 Citations
2,352 Views
12 Pages

Robust Frequency-Decoupling-Based Power Split of Battery/Supercapacitor Hybrid Energy Storage Systems in DC Microgrids

  • Mohamed Amine Hartani,
  • Messaoud Hamouda,
  • Othmane Abdelkhalek,
  • Aissa Benhamou and ,
  • Bouchaib Ali and
  • Saad Mekhilef
  • + 1 author+ 0 author

A frequency-decoupling-based power split was used in this study to manage a direct-current microgrid (DC-MG)-based PV and hybridized energy storage system (HESS), which consisted of a battery and a supercapacitor. The HESS control integrated a dual-l...

(This article belongs to the Proceedings of The 1st International Conference on Physics of Semiconductor Devices, Renewable Energies and Environment)
  • Article
  • Open Access
35 Citations
4,239 Views
23 Pages

9 June 2021

This paper proposes a current decoupling controller for a Doubly-fed Induction Generator (DFIG) based on floating offshore wind turbine and power to gas. The proposed controller realizes Maximum Power Point Tracking (MPPT) through integral sliding mo...

  • Article
  • Open Access
8 Citations
2,089 Views
17 Pages

23 June 2025

To enhance the speed control performance of the permanent magnet synchronous motor (PMSM) servo system, an improved sliding mode control method integrating a torque observer is presented. The current loop uses current feedback decoupling PID control,...

(This article belongs to the Special Issue Power Electronics and Motor Control)
  • Article
  • Open Access
8 Citations
7,927 Views
17 Pages

1 December 2017

Due to its simple mechanical structure and high motion stability, the H-shaped platform has been increasingly widely used in precision measuring, numerical control machining and semiconductor packaging equipment, etc. The H-shaped platform is normall...

(This article belongs to the Section I: Energy Fundamentals and Conversion)
  • Article
  • Open Access
9 Citations
3,694 Views
20 Pages

Robust Fault-Tolerant Control of a Five-Phase Permanent Magnet Synchronous Motor under an Open-Circuit Fault

  • Ayyoub Zeghlache,
  • Hemza Mekki,
  • Mohamed Fouad Benkhoris,
  • Ali Djerioui and ,
  • Djamel Ziane and
  • Samir Zeghlache
  • + 1 author+ 0 author

14 June 2024

This paper introduces a robust fault-tolerant control (FTC) for a five-phase permanent magnet synchronous motor (FPPMSM) affected by the third harmonic under an open-circuit fault (OCF). Using field-oriented control, the proposed method demonstrates...

(This article belongs to the Special Issue Multiport Converters for Renewable Energy Sources and EV (Electric Vehicle) Applications)

of 3