Skip to Content

512 Results Found

  • Communication
  • Open Access
1 Citations
5,578 Views
9 Pages

Overview of the CMS Detector Performance at LHC Run 2

  • Martina Ressegotti and
  • On behalf of the CMS Collaboration

9 January 2019

The Compact Muon Solenoid (CMS) detector is one of the two multipurpose experiments at the Large Hadron Collider (LHC). It has successfully collected data during Run 1 (2010–2013) and achieved important physics results, like the discovery of the Higg...

(This article belongs to the Special Issue Selected Papers from the 7th International Conference on New Frontiers in Physics (ICNFP 2018))
  • Article
  • Open Access
3 Citations
3,641 Views
32 Pages

15 February 2024

The Large Hadron Collider (LHC) is being prepared for an extensive upgrade to boost its particle discovery potential. The new phase, High Luminosity LHC, will operate at a factor-of-five-increased luminosity (the number proportional to the rate of co...

  • Article
  • Open Access
2,017 Views
15 Pages

Analysis of Measurements of the Magnetic Flux Density in Steel Blocks of the Compact Muon Solenoid Magnet Yoke with Solenoid Coil Fast Discharges

  • Vyacheslav Klyukhin,
  • Benoit Curé,
  • Andrea Gaddi,
  • Antoine Kehrli and ,
  • Maciej Ostrega and
  • Xavier Pons
  • + 1 author+ 0 author

19 December 2024

The general-purpose Compact Muon Solenoid (CMS) detector at the Large Hadron Collider (LHC) at CERN is used to study the production of new particles in proton–proton collisions at an LHC center of mass energy of 13.6 TeV. The detector includes a magn...

(This article belongs to the Section C: Physics)
  • Article
  • Open Access
2 Citations
2,675 Views
26 Pages

PREFACE: A Search for Long-Lived Particles at the Large Hadron Collider

  • Burak Hacisahinoglu,
  • Suat Ozkorucuklu,
  • Maksym Ovchynnikov,
  • Michael G. Albrow and ,
  • Aldo Penzo and
  • Orhan Aydilek
  • + 1 author+ 0 author

1 August 2025

The Standard Model (SM) fails to explain many problems (neutrino masses, dark matter, and matter–antimatter asymmetry, among others) that may be resolved with new particles beyond the SM. No observation of such new particles may be explained ei...

(This article belongs to the Section High Energy Physics)
  • Article
  • Open Access
525 Views
29 Pages

20 August 2026

LiDAR–camera fusion is widely used for 3D perception in intelligent connected vehicles, but a clean camera branch does not necessarily compensate for structured LiDAR corruption. We propose CMS-Attack, a cross-modal search framework in which on...

(This article belongs to the Special Issue AI-Driving for Autonomous Vehicles—2nd Edition)
  • Article
  • Open Access
28 Citations
8,474 Views
9 Pages

The Fabrication and Characterization of Ni/4H-SiC Schottky Diode Radiation Detectors with a Sensitive Area of up to 4 cm2

  • Lin-Yue Liu,
  • Ling Wang,
  • Peng Jin,
  • Jin-Liang Liu and ,
  • Xian-Peng Zhang,
  • Liang Chen,
  • Jiang-Fu Zhang,
  • Xiao-Ping Ouyang,
  • Ao Liu and
  • Song Bai
  • + 6 authors+ 1 author

13 October 2017

Silicon carbide (SiC) detectors of an Ni/4H-SiC Schottky diode structure and with sensitive areas of 1–4 cm2 were fabricated using high-quality lightly doped epitaxial 4H-SiC material, and were tested in the detection of alpha particles and pulsed X-...

(This article belongs to the Special Issue Sensors and Materials for Harsh Environments)
  • Article
  • Open Access
11 Citations
3,189 Views
28 Pages

18 April 2023

On-orbit geometric calibration of satellite-borne laser based on infrared detectors is the key tool to ensure the elevation measurement accuracy, and the accuracy of on-orbit geometric calibration is directly determined by laser spots captured by det...

  • Article
  • Open Access
14 Citations
4,413 Views
12 Pages

Incomplete Charge Collection at Inter-Pixel Gap in Low- and High-Flux Cadmium Zinc Telluride Pixel Detectors

  • Antonino Buttacavoli,
  • Fabio Principato,
  • Gaetano Gerardi,
  • Donato Cascio and ,
  • Giuseppe Raso,
  • Manuele Bettelli,
  • Andrea Zappettini,
  • Paul Seller,
  • Matthew C. Veale and
  • Leonardo Abbene
  • + 5 authors+ 0 author

13 February 2022

The success of cadmium zinc telluride (CZT) detectors in room-temperature spectroscopic X-ray imaging is now widely accepted. The most common CZT detectors are characterized by enhanced-charge transport properties of electrons, with mobility-lifetime...

(This article belongs to the Special Issue CdZnTe Radiation Detectors and Applications)
  • Communication
  • Open Access
5 Citations
2,718 Views
16 Pages

24 August 2021

This paper presents a method of measuring gas flow velocity based on the thermal time-of-flight method. The essence of the solution is an analysis of the time shift and the shape of voltage signals at the transmitter and at a temperature wave detecto...

(This article belongs to the Section Physical Sensors)
  • Article
  • Open Access
8 Citations
4,013 Views
14 Pages

Dual-Purpose Photometric-Conductivity Detector for Simultaneous and Sequential Measurements in Flow Analysis

  • Thitirat Mantim,
  • Korbua Chaisiwamongkhol,
  • Kanchana Uraisin,
  • Peter C. Hauser and ,
  • Prapin Wilairat and
  • Duangjai Nacapricha
  • + 1 author+ 0 author

This work presents a new dual-purpose detector for photometric and conductivity measurements in flow-based analysis. The photometric detector is a paired emitter–detector diode (PEDD) device, whilst the conductivity detection employs a capaciti...

(This article belongs to the Special Issue Modern Flow Analysis)
  • Article
  • Open Access
13 Citations
4,097 Views
11 Pages

1 December 2020

In this study, we investigated the characteristics of an organic-inorganic hybrid indirect-type X-ray detector with a CH3NH3PbI3 (MAPbI3) perovskite active layer. A layer with a thickness of 192 nm annealed at 100 °C showed higher absorption, hig...

(This article belongs to the Special Issue Room Temperature Semiconductor Detectors: Development and Applications)
  • Article
  • Open Access
7 Citations
4,147 Views
13 Pages

17 November 2020

In this paper, we studied the optimized conditions for adding inorganic quantum dots (QD) to the P3HT:PC70BM organic active layer to increase the sensitivity of the indirect X-ray detector. Commonly used QDs are composed of hazardous substances with...

(This article belongs to the Special Issue Room Temperature Semiconductor Detectors: Development and Applications)
  • Article
  • Open Access
16 Citations
8,431 Views
11 Pages

2 March 2016

A signal conditioning block of a 1 × 200 Complementary Metal-Oxide-Semiconductor (CMOS) detector array is proposed to be employed with a real-time 0.2 THz imaging system for inspecting large areas. The plasmonic CMOS detector array whose pixel size i...

(This article belongs to the Special Issue Infrared and THz Sensing and Imaging)
  • Article
  • Open Access
2 Citations
2,285 Views
12 Pages

Development of the CMS Magnetic Field Map

  • Nicola Amapane and
  • Vyacheslav Klyukhin

6 May 2023

This article focuses on pioneering work on the performance of the three-dimensional (3D) magnetic field map in the entire volume of the Compact Muon Solenoid (CMS) detector at the Large Hadron Collider at CERN. In the CMS heterogeneous magnetic syste...

(This article belongs to the Section C: Physics)
  • Article
  • Open Access
8 Citations
6,383 Views
12 Pages

Prototype of Nitro Compound Vapor and Trace Detector Based on a Capacitive MIS Sensor

  • Nikolay Samotaev,
  • Artur Litvinov,
  • Maya Etrekova,
  • Konstantin Oblov and ,
  • Dmitrii Filipchuk and
  • Alexey Mikhailov
  • + 1 author+ 0 author

10 March 2020

A prototype of a nitro compound vapor and trace detector, which uses the pyrolysis method and a capacitive gas sensor based on the metal–insulator–semiconductor (MIS) structure type Pd–SiO2–Si, was developed and manufactured....

  • Article
  • Open Access
3 Citations
2,572 Views
15 Pages

Investigations on the Performance of a 5 mm CdTe Timepix3 Detector for Compton Imaging Applications

  • Juan S. Useche Parra,
  • Gerardo Roque,
  • Michael K. Schütz,
  • Michael Fiederle and
  • Simon Procz

13 December 2024

Nuclear power plant decommissioning requires the rapid and accurate classification of radioactive waste in narrow spaces and under time constraints. Photon-counting detector technology offers an effective solution for the quick classification and det...

(This article belongs to the Special Issue Recent Advances in X-Ray Sensing and Imaging)
  • Article
  • Open Access
643 Views
12 Pages

The Damage Effects on a HgCdTe Detector of a Short-Infrared Pulsed Laser with Different Pulse Widths

  • Qiheng Wei,
  • Xianfeng Wu,
  • Lingyuan Wu,
  • Yongqiang Zhang and ,
  • Fuli Tan,
  • Bo Fu,
  • Wei Li and
  • Yanglong Li
  • + 3 authors+ 0 author

The high sensitivity of HgCdTe infrared detectors makes them highly vulnerable to laser irradiation, yet the influence of pulse width on damage behavior in the short-wave infrared (SWIR) band remains insufficiently understood. In this study, we exper...

(This article belongs to the Special Issue Photonic and Optoelectronic Devices and Systems, 5th Edition)
  • Article
  • Open Access
6 Citations
3,080 Views
9 Pages

14 November 2021

The radiation fluence of high luminosity LHC (HL-LHC) is predicted up to 1 × 1016 1 MeV neq/cm2 in the ATLAS and CMS experiments for the pixel detectors at the innermost layers. The increased radiation leads to the degradation of the detector propert...

(This article belongs to the Section A: Physics)
  • Article
  • Open Access
1 Citations
2,861 Views
14 Pages

Combined Spectroscopy System Utilizing Gas Electron Multiplier and Timepix3 Technology for Laser Plasma Experiments

  • Veronica De Leo,
  • Gerardo Claps,
  • Francesco Cordella,
  • Gabriele Cristoforetti and ,
  • Leonida Antonio Gizzi,
  • Petra Koester,
  • Danilo Pacella and
  • Antonella Tamburrino
  • + 3 authors+ 0 author

We present an innovative X-ray spectroscopy system to address the complex study of the X-ray emissions arising from laser–target interactions, where the emissions occur within extremely brief intervals from femtoseconds to nanoseconds. Our syst...

(This article belongs to the Special Issue High Precision X-ray Measurements 2023)
  • Article
  • Open Access
4 Citations
7,307 Views
23 Pages

28 January 2023

Inhalation and exhaust fans are installed inside a distribution panel for cooling. However, in the event of fire inside the panel, these fans change the flow of smoke, which interferes with quick detection by fire sensors installed on the panel ceili...

(This article belongs to the Special Issue Fire Detection and Public Safety)
  • Article
  • Open Access
4 Citations
3,962 Views
14 Pages

29 October 2022

Muon tomography (MT), based on atmospheric cosmic rays, is a promising technique suitable for nondestructive imaging of the internal structures of mountains. This method uses the measured flux distribution after attenuation, combined with the known m...

(This article belongs to the Section Applied Physics General)
  • Article
  • Open Access
11 Citations
2,288 Views
11 Pages

Vitacrystallography: Structural Biomarkers of Breast Cancer Obtained by X-ray Scattering

  • Sergey Denisov,
  • Benjamin Blinchevsky,
  • Jonathan Friedman,
  • Barbara Gerbelli and ,
  • Ash Ajeer,
  • Lois Adams,
  • Charlene Greenwood,
  • Keith Rogers,
  • Lev Mourokh and
  • Pavel Lazarev
  • + 5 authors+ 0 author

9 July 2024

With breast cancer being one of the most widespread causes of death for women, there is an unmet need for its early detection. For this purpose, we propose a non-invasive approach based on X-ray scattering. We measured samples from 107 unique patient...

(This article belongs to the Section Methods and Technologies Development)
  • Article
  • Open Access
1 Citations
4,305 Views
14 Pages

Cosmic-Ray Studies with Experimental Apparatus at LHC

  • Emma González Hernández,
  • Juan Carlos Arteaga,
  • Arturo Fernández Tellez and
  • Mario Rodríguez-Cahuantzi

15 October 2020

The study of cosmic rays with underground accelerator experiments started with the LEP detectors at CERN. ALEPH, DELPHI and L3 studied some properties of atmospheric muons such as their multiplicity and momentum. In recent years, an extension and imp...

(This article belongs to the Special Issue Cosmic Rays)
  • Article
  • Open Access
16 Citations
6,983 Views
37 Pages

Influence of Compartment Fire Behavior at Ignition and Combustion Development Stages on the Operation of Fire Detectors

  • Alena Zhdanova,
  • Roman Volkov,
  • Aleksandr Sviridenko,
  • Geniy Kuznetsov and
  • Pavel Strizhak

17 June 2022

This paper presents experimental research findings for those involved in the early phase of fire in office buildings. Class A model fires with a reaction area from 5 cm2 to 300 cm2 were chosen for investigation. To mock up a fire, the following combu...

(This article belongs to the Special Issue Pyrolysis, Ignition, Combustion and Fire Spread of Combustible Materials)
  • Article
  • Open Access
8 Citations
4,756 Views
12 Pages

18 May 2018

This paper presents the results of an attenuation model for remote depth estimation of buried radioactive wastes using a Cadmium Zinc Telluride (CZT) detector. Previous research using an organic liquid scintillator detector system showed that the mod...

(This article belongs to the Section Remote Sensors)
  • Article
  • Open Access
7 Citations
3,825 Views
10 Pages

1 March 2020

This study investigated the characteristics of an indirect-type hybrid X-ray detector with a conjugated polymer poly(3-hexylthiophene) (P3HT) and CdSe quantum dot (QD) blended active layer. To improve detection sensitivity, the optimal blending ratio...

(This article belongs to the Special Issue Coatings and Interfaces)
  • Article
  • Open Access
5 Citations
3,202 Views
11 Pages

6 April 2022

In this paper, we demonstrate the enhancement in detection sensitivity of an indirect X-ray detector based on poly(3-hexylthiophene) (P3HT) and fullerene derivatives [6,6]-phenyl-C71-butyric acid methyl ester (PC71BM) by adding perovskite quantum dot...

(This article belongs to the Special Issue Coatings and Interfaces II)
  • Article
  • Open Access
43 Citations
4,743 Views
16 Pages

Application of Gamma Attenuation Technique and Artificial Intelligence to Detect Scale Thickness in Pipelines in Which Two-Phase Flows with Different Flow Regimes and Void Fractions Exist

  • Mohammed Alamoudi,
  • Mohammad Amir Sattari,
  • Mohammed Balubaid,
  • Ehsan Eftekhari-Zadeh and ,
  • Ehsan Nazemi,
  • Osman Taylan and
  • El Mostafa Kalmoun
  • + 2 authors+ 0 author

2 July 2021

Scale deposits can reduce equipment efficiency in the oil and petrochemical industry. The gamma attenuation technique can be used as a non-invasive effective tool for detecting scale deposits in petroleum pipelines. The goal of this study is to propo...

(This article belongs to the Special Issue Symmetry in Fluid Flow II)
  • Article
  • Open Access
2,626 Views
16 Pages

Evaluation of a Low-Power Computer Vision-Based Positioning System for a Handheld Landmine Detector Using AprilTag Markers

  • Adam D. Fletcher,
  • Edward Cheadle,
  • John Davidson,
  • Daniel Conniffe and ,
  • Frank Podd and
  • Anthony J. Peyton
  • + 1 author+ 0 author

A positioning system employing visual fiducial markers (AprilTags) has been implemented for use with handheld mine detection equipment. To be suitable for a battery-powered real-time application, the system has been designed to operate at low power (...

  • Article
  • Open Access
16 Citations
5,477 Views
12 Pages

Development of Single Crystal CsPbBr3 Radiation Detectors from Low-Cost Solution Synthesized Material

  • David A. Kunar,
  • Matthew F. Webster,
  • Yu Wu,
  • Ramjee Kandel and
  • Peng Li Wang

3 May 2023

The all-inorganic perovskite CsPbBr3 is a strong candidate for room-temperature, semiconducting radiation detecting applications. With a high stopping power, a large bandgap, and a high mobility-lifetime (μτ) product for both holes and electro...

(This article belongs to the Section Inorganic Crystalline Materials)
  • Article
  • Open Access
7 Citations
5,573 Views
14 Pages

Investigating Influential Parameters for High-Purity Germanium Crystal Growth

  • Sanjay Bhattarai,
  • Dongming Mei,
  • Narayan Budhathoki,
  • Kunming Dong and
  • Austin Warren

10 February 2024

This paper focuses on the research and development of high-purity germanium (HPGe) crystals for detector fabrication, specifically targeting applications in rare-event physics searches. The primary objective was to produce large-scale germanium cryst...

  • Article
  • Open Access
4 Citations
8,262 Views
12 Pages

Gated Silicon Drift Detector Fabricated from a Low-Cost Silicon Wafer

  • Hideharu Matsuura,
  • Shungo Sakurai,
  • Yuya Oda,
  • Shinya Fukushima and ,
  • Shohei Ishikawa,
  • Akinobu Takeshita and
  • Atsuki Hidaka
  • + 2 authors+ 0 author

22 May 2015

Inexpensive high-resolution silicon (Si) X-ray detectors are required for on-site surveys of traces of hazardous elements in food and soil by measuring the energies and counts of X-ray fluorescence photons radially emitted from these elements. Gated...

(This article belongs to the Special Issue State-of-the-Art Sensors Technology in Japan 2015)
  • Article
  • Open Access
9 Citations
3,636 Views
12 Pages

Ion mobility spectrometry instrumentation today is widespread in the area of transport security and counterterrorism. This method of detection of explosive substances is highly appreciated for the existence of portable detectors capable of detecting...

(This article belongs to the Section Analytical Methods, Instrumentation and Miniaturization)
  • Review
  • Open Access
5 Citations
5,310 Views
22 Pages

The CMS Magnetic Field Measuring and Monitoring Systems

  • Vyacheslav Klyukhin,
  • Austin Ball,
  • Felix Bergsma,
  • Henk Boterenbrood and ,
  • Benoit Curé,
  • Domenico Dattola,
  • Andrea Gaddi,
  • Hubert Gerwig,
  • Alain Hervé and
  • Jerry Zimmerman
  • + 9 authors+ 4 authors

15 January 2022

This review article describes the performance of the magnetic field measuring and monitoring systems for the Compact Muon Solenoid (CMS) detector. To cross-check the magnetic flux distribution obtained with the CMS magnet model, four systems for meas...

(This article belongs to the Section C: Physics)
  • Article
  • Open Access
11 Citations
7,647 Views
11 Pages

A Photoactivated Gas Detector for Toluene Sensing at Room Temperature Based on New Coral-Like ZnO Nanostructure Arrays

  • Li-Ko Yeh,
  • Jie-Chun Luo,
  • Min-Chun Chen,
  • Chih-Hung Wu and ,
  • Jian-Zhang Chen,
  • I-Chun Cheng,
  • Cheng-Che Hsu and
  • Wei-Cheng Tian
  • + 3 authors+ 0 author

31 October 2016

A photoactivated gas detector operated at room temperature was microfabricated using a simple hydrothermal method. We report that the photoactivated gas detector can detect toluene using a UV illumination of 2 μW/cm2. By ultraviolet (UV) illumination...

(This article belongs to the Special Issue Materials and Applications for Sensors and Transducers)
  • Article
  • Open Access
2 Citations
1,078 Views
13 Pages

MBE Growth of High-Quality HgCdSe for Infrared Detector Applications

  • Zekai Zhang,
  • Wenwu Pan,
  • Gilberto A. Umana Membreno,
  • Shuo Ma and ,
  • Lorenzo Faraone and
  • Wen Lei
  • + 1 author+ 0 author

5 August 2025

HgCdSe has recently been proposed as a potential alternative material to HgCdTe for fabricating high-performance infrared detectors. This work presents a study on the growth of high-crystalline-quality HgCdSe materials on GaSb (211)B substrates via m...

(This article belongs to the Special Issue Material Design and Optimization for Opto-Electronic Devices)
  • Article
  • Open Access
3 Citations
3,430 Views
13 Pages

Thermal Damage Characterization of Detector Induced by Nanosecond Pulsed Laser Irradiation

  • Zhilong Jian,
  • Weijing Zhou,
  • Hao Chang,
  • Yingjie Ma and ,
  • Xiaoyuan Quan and
  • Zikang Wang
  • + 1 author+ 0 author

Experimental and simulation analysis was conducted on the effects of 532 nm nanosecond laser-induced thermal damage on the front-side illuminated CMOS detector. The study examined CMOS detector output images at different stages of damage, including p...

(This article belongs to the Section Lasers, Light Sources and Sensors)
  • Review
  • Open Access
7 Citations
4,989 Views
18 Pages

10 June 2021

This review describes the composition of the Compact Muon Solenoid (CMS) detector and the methodology for modelling the heterogeneous CMS magnetic system, starting with the formulation of the magnetostatics problem for modelling the magnetic flux of...

(This article belongs to the Section C: Physics)
  • Article
  • Open Access
4 Citations
2,720 Views
14 Pages

A Large Area Pixelated Silicon Array Detector for Independent Transit In Vivo Dosimetry

  • Owen J. Brace,
  • Iolanda Fuduli,
  • Saree Alnaghy,
  • Albert T. Le and ,
  • Jeremy A. Davis,
  • Trent Causer,
  • Dean Wilkinson,
  • Aleksandr Perevertaylo,
  • Anatoly B. Rosenfeld and
  • Marco Petasecca
  • + 5 authors+ 0 author

6 January 2022

A large area pixelated silicon array detector named “MP987” has been developed for in vivo dosimetry. The detector was developed to overcome the non-water equivalent response of EPID (Electronic Portal Imaging Device) dosimetry systems, d...

(This article belongs to the Special Issue Detectors for Medical Physics)
  • Article
  • Open Access
25 Citations
5,412 Views
13 Pages

Reliable Fast (20 Hz) Acquisition Rate by a TD fNIRS Device: Brain Resting-State Oscillation Studies

  • Rebecca Re,
  • Ileana Pirovano,
  • Davide Contini,
  • Caterina Amendola and ,
  • Letizia Contini,
  • Lorenzo Frabasile,
  • Pietro Levoni,
  • Alessandro Torricelli and
  • Lorenzo Spinelli
  • + 4 authors+ 0 author

24 December 2022

A high power setup for multichannel time-domain (TD) functional near infrared spectroscopy (fNIRS) measurements with high efficiency detection system was developed. It was fully characterized based on international performance assessment protocols fo...

(This article belongs to the Special Issue Biomedical Sensors for Functional Mapping: Techniques, Methods, Experimental and Medical Applications)
  • Article
  • Open Access
59 Citations
6,214 Views
12 Pages

Silicon Carbide Microstrip Radiation Detectors

  • Donatella Puglisi and
  • Giuseppe Bertuccio

30 November 2019

Compared with the most commonly used silicon and germanium, which need to work at cryogenic or low temperatures to decrease their noise levels, wide-bandgap compound semiconductors such as silicon carbide allow the operation of radiation detectors at...

(This article belongs to the Special Issue SiC based Miniaturized Devices)
  • Article
  • Open Access
18 Citations
5,785 Views
13 Pages

Design and Fabrication of a Low-Cost Thermopile Infrared Detector

  • Ting Liang,
  • Yihao Guan,
  • Cheng Lei,
  • Xuezhan Wu and ,
  • Yuehang Bai,
  • Jijun Xiong and
  • Lei Qi
  • + 2 authors+ 0 author

21 September 2021

In this paper, we design and optimize a low-cost, closed-film structure of a microelectromechanical systems (MEMS) thermopile infrared detector. By optimizing the circular arrangement of thermocouple strips and the thermal isolation design of the col...

  • Article
  • Open Access
2 Citations
1,607 Views
13 Pages

Real-Time Dose Measurement in Brachytherapy Using Scintillation Detectors Based on Ce3+-Doped Garnet Crystals

  • Sandra Witkiewicz-Łukaszek,
  • Bogna Sobiech,
  • Janusz Winiecki and
  • Yuriy Zorenko

23 July 2025

Conventional detectors based on ionization chambers, semiconductors, or thermoluminescent materials generally cannot be used to verify the in vivo dose delivered during brachytherapy treatments with γ-ray sources. However, certain adaptations a...

(This article belongs to the Special Issue Recent Advances in Scintillator Materials)
  • Article
  • Open Access
18 Citations
3,807 Views
12 Pages

29 March 2022

Photodetectors convert optical signals into electrical signals and demonstrate application potential in various fields, such as optical communication, image detection, environmental monitoring, and optoelectronics. In this study, a mixed cation&ndash...

(This article belongs to the Special Issue Nanogenerator for Self-Powering Indoor Electronics)
  • Article
  • Open Access
16 Citations
5,006 Views
11 Pages

Spray Coated Colloidal Quantum Dot Films for Broadband Photodetectors

  • Kaixuan Song,
  • Jifeng Yuan,
  • Ting Shen,
  • Jiuyao Du and ,
  • Ruiqi Guo,
  • Tönu Pullerits and
  • Jianjun Tian
  • + 2 authors+ 0 author

6 December 2019

A technique for scalable spray coating of colloidal CdSeTe quantum dots (QDs) for photovoltaics and photodetector applications is presented. A mixture solvent with water and ethanol was introduced to enhance the adhesive force between QDs and the sub...

(This article belongs to the Special Issue Quantum Dots and Micro-LED Display)
  • Article
  • Open Access
1 Citations
2,538 Views
14 Pages

User Evaluation of Head-Level Obstacle Detector for Visually Impaired

  • Iva Klimešová,
  • Ján Lešták,
  • Karel Hána,
  • Tomáš Veselý and
  • Pavel Smrčka

The white cane is a reliable and often-used assistive aid; however, it does not protect against obstacles at the head level. We designed and built an ultrasonic-based obstacle detector with a limited detection field in front of the head. The detector...

(This article belongs to the Section Assistive Technologies)
  • Article
  • Open Access
4 Citations
3,101 Views
14 Pages

A Two-Dimensional Non-Destructive Beam Monitoring Detector for Ion Beams

  • Saverio Braccini,
  • Tommaso Stefano Carzaniga,
  • Pierluigi Casolaro,
  • Gaia Dellepiane and ,
  • Laura Franconi,
  • Isidre Mateu,
  • Paola Scampoli and
  • Matthias Schmid
  • + 3 authors+ 0 author

13 March 2023

A two-dimensional beam monitoring detector named π2 has been developed and tested at the Bern University Hospital, using an 18 MeV proton beam provided by a medical cyclotron. This non-destructive device utilises a scintillating compound (P47 phos...

(This article belongs to the Section Applied Physics General)
  • Article
  • Open Access
2 Citations
3,364 Views
10 Pages

18 October 2021

The absorbers method is here applied by interposing filters of variable thickness between the X-ray source and a detector so to attenuate the radiation intensity by using the attenuation coefficient as a selective photon energy operator. The analysis...

  • Feature Paper
  • Article
  • Open Access
4,102 Views
6 Pages

Proton Radiography by Multiple Coulomb Scattering with Nuclear Emulsion Detectors

  • Saverio Braccini,
  • Tommaso S. Carzaniga,
  • Giulia Pisegna and
  • Paola Scampoli

The possibility of performing proton radiography by using the proton angular spread due to Coulomb multiple scattering was investigated, for the first time, with an emulsion film detector. Two different phantoms were irradiated with the therapeutic p...

(This article belongs to the Collection Selected Papers from Instruments’ Editorial Board Members)
  • Article
  • Open Access
2 Citations
3,406 Views
8 Pages

30 March 2020

Simple estimations show that the thermoelectric readout in graphene radiation detectors can be extremely effective even for graphene with modest charge-carrier mobility ∼1000 cm 2 /(Vs). The detector responsivity depends mostly on the resi...

(This article belongs to the Section Sensor Materials)

of 11