Special Issue "Room Temperature Semiconductor Detectors: Development and Applications"

A special issue of Sensors (ISSN 1424-8220). This special issue belongs to the section "Physical Sensors".

Deadline for manuscript submissions: 31 March 2021.

Special Issue Editors

Dr. Leonardo Abbene
Website
Guest Editor
Dipartimento di Fisica e Chimica - Emilio Segrè, University of Palermo, Viale delle Scienze, Edificio 18, Palermo 90128, Italy
Interests: X-ray and gamma-ray detectors; CdTe and CdZnTe detectors; digital pulse processing electronics; medical applications; astrophysical applications
Dr. Matthew Charles Veale
Website
Guest Editor
Rutherford Appleton Laboratory, UKRI Science & Technology Facilities Council, Oxfordshire, UK
Interests: Compound Semiconductors; X-Ray Imaging;X-Ray Spectroscopy; MHz Imaging
Dr. Andrea Zappettini
Website
Guest Editor
IMEM-CNR,Istituto Materiali per l’Elettronica e il Magnetismo, Consiglio Nazionale delle Ricerche Parco Area delle Scienze 37/A 43124 Parma, Italy
Interests: development of x and gamma ray detectors based on CzZnTe: crystal growth, material characterization, device processing, detector characterization

Special Issue Information

Dear Colleagues,

Over the last two decades, room-temperature semiconductor detectors (RTSDs) have been extensively proposed for X-ray and gamma-ray spectroscopy and imaging, opening new perspectives in several application areas such as synchrotron science, homeland security, medical imaging, and astrophysics. RTSDs are an important class of X-ray and gamma-ray sensors able to perform high-resolution spectroscopy near room-temperature conditions. Several high-Z and wide-bandgap compound semiconductors (CdTe, CdZnTe, GaAs, HgI2, TlBr) have been developed, and continuous efforts have been made in the advancement of the crystal growth and device fabrication technologies.

In this framework, we are glad to edit this Special Issue on “Room Temperature Semiconductor Detectors: Development and Applications".

This Special Issue aims to receive submissions of both review and original research articles related to the state-of-the-art in RTSD sensors as well as prospects for future developments and applications.

Dr. Leonardo Abbene
Dr. Matthew Charles Veale
Dr. Andrea Zappettini
Guest Editors

Manuscript Submission Information

Manuscripts should be submitted online at www.mdpi.com by registering and logging in to this website. Once you are registered, click here to go to the submission form. Manuscripts can be submitted until the deadline. All papers will be peer-reviewed. Accepted papers will be published continuously in the journal (as soon as accepted) and will be listed together on the special issue website. Research articles, review articles as well as short communications are invited. For planned papers, a title and short abstract (about 100 words) can be sent to the Editorial Office for announcement on this website.

Submitted manuscripts should not have been published previously, nor be under consideration for publication elsewhere (except conference proceedings papers). All manuscripts are thoroughly refereed through a single-blind peer-review process. A guide for authors and other relevant information for submission of manuscripts is available on the Instructions for Authors page. Sensors is an international peer-reviewed open access semimonthly journal published by MDPI.

Please visit the Instructions for Authors page before submitting a manuscript. The Article Processing Charge (APC) for publication in this open access journal is 2200 CHF (Swiss Francs). Submitted papers should be well formatted and use good English. Authors may use MDPI's English editing service prior to publication or during author revisions.

Keywords

  • compound semiconductor detectors
  • X-ray and gamma-ray detectors
  • CdZnTe detectors
  • CdTe detectors
  • GaAs detectors
  • HgI2 detectors
  • TlBr detectors
  • SiC detectors
  • energy-resolved X-ray imaging
  • medical imaging

Published Papers (9 papers)

Order results
Result details
Select all
Export citation of selected articles as:

Research

Jump to: Other

Open AccessArticle
Characterization of Chromium Compensated GaAs Sensors with the Charge-Integrating JUNGFRAU Readout Chip by Means of a Highly Collimated Pencil Beam
Sensors 2021, 21(4), 1550; https://doi.org/10.3390/s21041550 (registering DOI) - 23 Feb 2021
Abstract
Chromium compensated GaAs or GaAs:Cr sensors provided by the Tomsk State University (Russia) were characterized using the low noise, charge integrating readout chip JUNGFRAU with a pixel pitch of 75 × 75 µm2 regarding its application as an X-ray detector at synchrotrons [...] Read more.
Chromium compensated GaAs or GaAs:Cr sensors provided by the Tomsk State University (Russia) were characterized using the low noise, charge integrating readout chip JUNGFRAU with a pixel pitch of 75 × 75 µm2 regarding its application as an X-ray detector at synchrotrons sources or FELs. Sensor properties such as dark current, resistivity, noise performance, spectral resolution capability and charge transport properties were measured and compared with results from a previous batch of GaAs:Cr sensors which were produced from wafers obtained from a different supplier. The properties of the sample from the later batch of sensors from 2017 show a resistivity of 1.69 × 109 Ω/cm, which is 47% higher compared to the previous batch from 2016. Moreover, its noise performance is 14% lower with a value of (101.65 ± 0.04) e ENC and the resolution of a monochromatic 60 keV photo peak is significantly improved by 38% to a FWHM of 4.3%. Likely, this is due to improvements in charge collection, lower noise, and more homogeneous effective pixel size. In a previous work, a hole lifetime of 1.4 ns for GaAs:Cr sensors was determined for the sensors of the 2016 sensor batch, explaining the so-called “crater effect” which describes the occurrence of negative signals in the pixels around a pixel with a photon hit due to the missing hole contribution to the overall signal causing an incomplete signal induction. In this publication, the “crater effect” is further elaborated by measuring GaAs:Cr sensors using the sensors from 2017. The hole lifetime of these sensors was 2.5 ns. A focused photon beam was used to illuminate well defined positions along the pixels in order to corroborate the findings from the previous work and to further characterize the consequences of the “crater effect” on the detector operation. Full article
Show Figures

Figure 1

Open AccessArticle
The Spectral X-ray Imaging Data Acquisition (SpeXIDAQ) Framework
Sensors 2021, 21(2), 563; https://doi.org/10.3390/s21020563 - 14 Jan 2021
Abstract
Photon counting X-ray imagers have found their way into the mainstream scientific community in recent years, and have become important components in many scientific setups. These camera systems are in active development, with output data rates increasing significantly with every new generation of [...] Read more.
Photon counting X-ray imagers have found their way into the mainstream scientific community in recent years, and have become important components in many scientific setups. These camera systems are in active development, with output data rates increasing significantly with every new generation of devices. A different class of PCD (Photon Counting Detector) devices has become generally available, where camera data output is no longer a matrix of photon counts but instead direct measurements of the deposited charge per pixel in every frame, which requires significant off-camera processing. This type of PCD, called a hyperspectral X-ray camera due to its fully spectroscopic output, yet again increases the demands put on the acquisition and processing backend. Not only are bandwidth requirements increased, but the need to do extensive data processing is also introduced with these hyperspectral PCD devices. To cope with these new developments the Spectral X-ray Imaging Data Acquisition framework (SpeXIDAQ) has been developed. All aspects of the imaging pipeline are handled by the SpeXIDAQ framework: from detector control and frame grabbing, to processing, storage and live visualisation during experiments. Full article
Show Figures

Figure 1

Open AccessArticle
Characteristics of a Hybrid Detector Combined with a Perovskite Active Layer for Indirect X-ray Detection
Sensors 2020, 20(23), 6872; https://doi.org/10.3390/s20236872 - 01 Dec 2020
Abstract
In this study, we investigated the characteristics of an organic-inorganic hybrid indirect-type X-ray detector with a CH3NH3PbI3 (MAPbI3) perovskite active layer. A layer with a thickness of 192 nm annealed at 100 °C showed higher absorption, [...] Read more.
In this study, we investigated the characteristics of an organic-inorganic hybrid indirect-type X-ray detector with a CH3NH3PbI3 (MAPbI3) perovskite active layer. A layer with a thickness of 192 nm annealed at 100 °C showed higher absorption, higher crystallinity, and lower surface roughness than did perovskite layers made under different conditions. In the indirect X-ray detector, a scintillator coupled with the detector to convert X-ray photons to visible photons, and the converted photons were absorbed by the active layer to generate charge carriers. The detector with the optimized MAPbI3 (192 nm thick and 100 °C annealing condition) active layer was coupled with a CsI(Tl) scintillator which consisted of 400 μm thick CsI and 0.5 mm thick Al, and achieved the highest sensitivity, i.e., 2.84 mA/Gy·cm2. In addition, the highest short-circuit current density (JSC), i.e., 18.78 mA/cm2, and the highest mobility, i.e., 2.83 × 10−4 cm2/V·s, were obtained from the same detector without the CsI(Tl) scintillator. Full article
Show Figures

Figure 1

Open AccessArticle
A Study on an Organic Semiconductor-Based Indirect X-ray Detector with Cd-Free QDs for Sensitivity Improvement
Sensors 2020, 20(22), 6562; https://doi.org/10.3390/s20226562 - 17 Nov 2020
Abstract
In this paper, we studied the optimized conditions for adding inorganic quantum dots (QD) to the P3HT:PC70BM organic active layer to increase the sensitivity of the indirect X-ray detector. Commonly used QDs are composed of hazardous substances with environmental problems, so [...] Read more.
In this paper, we studied the optimized conditions for adding inorganic quantum dots (QD) to the P3HT:PC70BM organic active layer to increase the sensitivity of the indirect X-ray detector. Commonly used QDs are composed of hazardous substances with environmental problems, so indium phosphide (InP) QDs were selected as the electron acceptor in this experiment. Among the three different sizes of InP QDs (4, 8, and 12 nm in diameter), the detector with 4 nm InP QDs showed the highest sensitivity, of 2.01 mA/Gy·cm2. To further improve the sensitivity, the QDs were fixed to 4 nm in diameter and then the amount of QDs added to the organic active layer was changed from 0 to 5 mg. The highest sensitivity, of 2.26 mA/Gy·cm2, was obtained from the detector with a P3HT:PC70BM:InP QDs (1 mg) active layer. In addition, the highest mobility, of 1.69 × 10−5 cm2/V·s, was obtained from the same detector. Compared to the detector with the pristine P3HT:PC70BM active layer, the detector with a P3HT:PC70BM:InP QDs (1 mg) active layer had sensitivity that was 61.87% higher. The cut-off frequency of the P3HT:PC70BM detector was 21.54 kHz, and that of the P3HT:PC70BM:InP QDs (1 mg) detector was 26.33 kHz, which was improved by 22.24%. Full article
Show Figures

Figure 1

Open AccessArticle
CdTe Based Energy Resolving, X-ray Photon Counting Detector Performance Assessment: The Effects of Charge Sharing Correction Algorithm Choice
Sensors 2020, 20(21), 6093; https://doi.org/10.3390/s20216093 - 27 Oct 2020
Abstract
Most modern energy resolving, photon counting detectors employ small (sub 1 mm) pixels for high spatial resolution and low per pixel count rate requirements. These small pixels can suffer from a range of charge sharing effects (CSEs) that degrade both spectral analysis and [...] Read more.
Most modern energy resolving, photon counting detectors employ small (sub 1 mm) pixels for high spatial resolution and low per pixel count rate requirements. These small pixels can suffer from a range of charge sharing effects (CSEs) that degrade both spectral analysis and imaging metrics. A range of charge sharing correction algorithms (CSCAs) have been proposed and validated by different groups to reduce CSEs, however their performance is often compared solely to the same system when no such corrections are made. In this paper, a combination of Monte Carlo and finite element methods are used to compare six different CSCAs with the case where no CSCA is employed, with respect to four different metrics: absolute detection efficiency, photopeak detection efficiency, relative coincidence counts, and binned spectral efficiency. The performance of the various CSCAs is explored when running on systems with pixel pitches ranging from 100 µm to 600µm, in 50 µm increments, and fluxes from 106 to 108 photons mm−2 s−1 are considered. Novel mechanistic explanations for the difference in performance of the various CSCAs are proposed and supported. This work represents a subset of a larger project in which pixel pitch, thickness, flux, and CSCA are all varied systematically. Full article
Show Figures

Figure 1

Open AccessArticle
Characterization of the Uniformity of High-Flux CdZnTe Material
Sensors 2020, 20(10), 2747; https://doi.org/10.3390/s20102747 - 12 May 2020
Cited by 2
Abstract
Since the late 2000s, the availability of high-quality cadmium zinc telluride (CdZnTe) has greatly increased. The excellent spectroscopic performance of this material has enabled the development of detectors with volumes exceeding 1 cm3 for use in the detection of nuclear materials. CdZnTe [...] Read more.
Since the late 2000s, the availability of high-quality cadmium zinc telluride (CdZnTe) has greatly increased. The excellent spectroscopic performance of this material has enabled the development of detectors with volumes exceeding 1 cm3 for use in the detection of nuclear materials. CdZnTe is also of great interest to the photon science community for applications in X-ray imaging cameras at synchrotron light sources and free electron lasers. Historically, spatial variations in the crystal properties and temporal instabilities under high-intensity irradiation has limited the use of CdZnTe detectors in these applications. Recently, Redlen Technologies have developed high-flux-capable CdZnTe material (HF-CdZnTe), which promises improved spatial and temporal stability. In this paper, the results of the characterization of 10 HF-CdZnTe detectors with dimensions of 20.35 mm × 20.45 mm × 2.00 mm are presented. Each sensor has 80 × 80 pixels on a 250-μm pitch and were flip-chip-bonded to the STFC HEXITEC ASIC. These devices show excellent spectroscopic performance at room temperature, with an average Full Width at Half Maximum (FWHM) of 0.83 keV measured at 59.54 keV. The effect of tellurium inclusions in these devices was found to be negligible; however, some detectors did show significant concentrations of scratches and dislocation walls. An investigation of the detector stability over 12 h of continuous operation showed negligible changes in performance. Full article
Show Figures

Figure 1

Open AccessArticle
A Prototype VP-PET Imaging System Based on Highly Pixelated CdZnTe Detectors
Sensors 2020, 20(5), 1294; https://doi.org/10.3390/s20051294 - 27 Feb 2020
Abstract
We investigated a prototype virtual-pinhole positron emission tomography (PET) system for small-animal imaging applications. The PET detector modules were made up of 1.3 mm lutetium-yttrium oxyorthosilicate (LYSO) arrays, and the insert detectors consisted of 0.6 mm pixelated cadmium zinc telluride (CdZnTe). To validate [...] Read more.
We investigated a prototype virtual-pinhole positron emission tomography (PET) system for small-animal imaging applications. The PET detector modules were made up of 1.3 mm lutetium-yttrium oxyorthosilicate (LYSO) arrays, and the insert detectors consisted of 0.6 mm pixelated cadmium zinc telluride (CdZnTe). To validate the imaging experiment, we did a Monte Carlo simulation for the virtual-pinhole PET (VP-PET) system in the Geant4 Application for Emission Tomography (GATE). For a point source of 22Na with a 0.5 mm diameter, the filtered back-projection algorithm-reconstructed PET image showed a resolution of 0.7 mm full-width-at-half-maximum. The system sensitivity was 0.46 cps/kBq at the center of the field view of the PET system with a source activity of 0.925 MBq and an energy window of 350 to 650 keV. A rod source phantom and a Derenzo phantom with 18F were also simulated to investigate the PET imaging ability. GATE simulation indicated that sources with 0.5 mm diameter could be clearly detected using 0.6 mm pixelated CdZnTe detectors as insert devices in a VP-PET system. Full article
Show Figures

Figure 1

Other

Jump to: Research

Open AccessLetter
Gamma-Ray Spectral Unfolding of CdZnTe-Based Detectors Using a Genetic Algorithm
Sensors 2020, 20(24), 7316; https://doi.org/10.3390/s20247316 - 19 Dec 2020
Abstract
The analysis of γ-ray spectra can be an arduous task, especially in the case of room temperature semiconductor detectors, where several distortions and instrumental artifacts conceal the true spectral shape. We developed a genetic algorithm to perform the unfolding of γ-spectra [...] Read more.
The analysis of γ-ray spectra can be an arduous task, especially in the case of room temperature semiconductor detectors, where several distortions and instrumental artifacts conceal the true spectral shape. We developed a genetic algorithm to perform the unfolding of γ-spectra in order to restore the true energy distribution of the incoming radiation. We successfully validated our approach on experimental spectra of four radionuclides (241Am, 57Co, 137Cs and 133Ba) acquired with two CdZnTe-based detectors with different contact geometries (single pixel and drift strip). The unfolded spectra consist of δ-like peaks in correspondence with the radiation emissions of each radioisotope. Full article
Show Figures

Figure 1

Open AccessLetter
Influence of Surface and Bulk Defects on Contactless Resistivity Measurements of CdTe and Related Compounds
Sensors 2020, 20(15), 4347; https://doi.org/10.3390/s20154347 - 04 Aug 2020
Abstract
We analyzed the influence of parameters of deep levels in the bulk and conditions on the surface on transient charge responses of semi-insulating samples (CdTe and GaAs). We studied the dependence on the applied bias step used for the experimental evaluation of resistivity [...] Read more.
We analyzed the influence of parameters of deep levels in the bulk and conditions on the surface on transient charge responses of semi-insulating samples (CdTe and GaAs). We studied the dependence on the applied bias step used for the experimental evaluation of resistivity in contactless measurement setups. We used simulations based on simultaneous solutions of 1D drift diffusion and Poisson’s equations as the main investigation tool. We found out that the resistivity can be reliably determined by the transient contactless method in materials with a large density of deep levels in the bulk (e.g., semi-insulating GaAs) when the response curve is described by a single exponential. In contrast, the materials with the low deep-level density, like semiconductor radiation detector materials (e.g., CdTe, CdZnTe, etc.), usually exhibit a complex response to applied bias, depending on the surface conditions. We show that a single exponential fit does not represent the true relaxation time and resistivity, in this case. A two-exponential fit can be used for a rough estimate of bulk material resistivity only in a limit of low-applied bias, when the response curve approaches a single-exponential shape. A decreasing of the bias leads to a substantially improved agreement between the evaluated and true relaxation time, which is also consistent with the approaching of the relaxation curve to the single-exponential shape. Full article
Show Figures