Skip to Content
You are currently on the new version of our website. Access the old version .

48 Results Found

  • Technical Note
  • Open Access
3 Citations
3,980 Views
9 Pages

4 February 2025

Background: We have applied an anterior locking compression mini plate in addition to a conventional superior locking compression plate for the treatment of wedge or multifragmentary clavicular fractures. Methods: Medical and radiologic data were ret...

(This article belongs to the Section Orthopedics)
  • Article
  • Open Access
16 Citations
7,715 Views
11 Pages

22 November 2020

This study investigated the incidence of failure after locking compression plate (LCP) osteosynthesis around a well-fixed stem of periprosthetic femoral fractures (PFFs). We retrospectively evaluated outcomes of 63 Vancouver type B1 and C PFFs treate...

(This article belongs to the Section Orthopedics)
  • Article
  • Open Access
6 Citations
3,372 Views
12 Pages

Feasibility of 3D-Printed Locking Compression Plates with Polyether Ether Ketone (PEEK) in Tibial Comminuted Diaphyseal Fractures

  • Hyung-Jin Chung,
  • Ho-Beom Lee,
  • Kwang-Min Park,
  • Tae-Gon Jung and ,
  • Sang-Bum Kim,
  • Byoung-Gu Lee,
  • Wan-Chin Kim and
  • Jeong-Kil Lee
  • + 3 authors+ 0 author

16 July 2023

The applicability of a polyether ether ketone locking compression plate (PEEK LCP) fabricated using FDM (fused deposition modeling)-based 3D printing to treat actual patients was studied. Three different tests—bending, axial compression, and ax...

(This article belongs to the Section Polymer Applications)
  • Feature Paper
  • Article
  • Open Access
53 Citations
10,662 Views
18 Pages

Failure Analysis of a Humeral Shaft Locking Compression Plate—Surface Investigation and Simulation by Finite Element Method

  • Iulian Vasile Antoniac,
  • Dan Ioan Stoia,
  • Brandusa Ghiban,
  • Camelia Tecu and ,
  • Florin Miculescu,
  • Cosmina Vigaru and
  • Vicentiu Saceleanu
  • + 2 authors+ 0 author

6 April 2019

A case study of a failed humeral shaft locking compression plate is presented, starting with a clinical case where failure occurred and an implant replacement was required. This study uses finite element method (FEM) in order to determine the failure...

(This article belongs to the Special Issue Selected Papers from BIOMMEDD 2018 Conference—Biomaterials)
  • Brief Report
  • Open Access
1 Citations
1,516 Views
8 Pages

Unicortical Locking Screws Provide Comparable Rigidity to Bicortical Compression Screws in Tranverse Mid-Shaft Clavicle Fracture Plate Fixation Constructs

  • Curtis W. Hartman,
  • Nicholas C. Branting,
  • Matthew A. Mormino,
  • Timothy J. Lackner and ,
  • Bradford P. Zitsch,
  • Edward V. Fehringer and
  • Hani Haider
  • + 2 authors+ 0 author

Background: Mid-shaft clavicle fracture fixation carries neurovascular injury risk. The purpose of this study was to compare bicortical compression and unicortical locked clavicle plate constructs biomechanically. Materials and Methods: Ten fourth-ge...

  • Article
  • Open Access
2 Citations
2,500 Views
12 Pages

Background and Objectives: Acetabular fractures, though infrequent, present considerable challenges in treatment due to their association with high-energy trauma and poor prognoses. Posterior wall fractures, the most common type among them, typically...

(This article belongs to the Section Orthopedics)
  • Article
  • Open Access
11 Citations
4,065 Views
12 Pages

First Tarsometatarsal Joint Fusion in Foot—A Biomechanical Human Anatomical Specimen Analysis with Use of Low-Profile Nitinol Staples Acting as Continuous Compression Implants

  • Andrew Sands,
  • Ivan Zderic,
  • Michael Swords,
  • Dominic Gehweiler and ,
  • Daniel Ciric,
  • Christoph Roth,
  • Christoph Nötzli and
  • Boyko Gueorguiev
  • + 3 authors+ 0 author

15 July 2023

Background and Objectives: The aim of this study was to investigate under dynamic loading the potential biomechanical benefit of simulated first tarsometatarsal (TMT-1) fusion with low-profile superelastic nitinol staples used as continuous compressi...

  • Article
  • Open Access
3 Citations
4,486 Views
11 Pages

Differences between Two Methods to Stabilize Supramalleolar Osteotomies in Children—A Retrospective Case Series

  • Thomas Schlemmer,
  • Reinald Brunner,
  • Bernhard Speth,
  • Johannes Mayr and
  • Erich Rutz

27 January 2021

Supramalleolar osteotomy (SMO) in pediatric patients can be fixed in various ways. We analyzed the records of 77 pediatric patients (124 SMOs) aged ≤16 years. In 56 patients (96 SMOs), K-wires were used to stabilize SMOs (WF group), while 21 patie...

(This article belongs to the Section Pediatric Surgery)
  • Article
  • Open Access
5 Citations
215 Views

1 September 2017

Background: The distal ulna hook plate was recently introduced for the treatment of fifth metatarsal base fractures, but no special articles have reported the surgical results of the plate fixation of displaced or comminuted fifth metatarsal base fra...

  • Case Report
  • Open Access
438 Views
11 Pages

Limb-Sparing Resection with Prophylactic Tibial Fixation and Medial Gastrocnemius Flap Reconstruction for Recurrent Leiomyosarcoma in a Previously Irradiated Leg: A Case Report

  • Georgi P. Luchev,
  • Lyubomir Gaydarski,
  • Svetoslav A. Slavchev,
  • Ahmed Al-Sadek and ,
  • Vera Megdanova,
  • Iva N. Dimitrova and
  • Georgi P. Georgiev
  • + 2 authors+ 0 author

4 September 2026

Background and Clinical Significance: Local recurrence of extremity leiomyosarcoma after multiple operations and radiotherapy presents a major therapeutic challenge. Adequate oncologic clearance must be balanced against preservation of skeletal stabi...

  • Article
  • Open Access
1,350 Views
14 Pages

Schatzker type V bicondylar tibial plateau fractures present a major challenge due to the difficulty of achieving stable fixation with minimally invasive strategies. This study introduces a dual-thread lag and locking plate (DLLP) design that integra...

(This article belongs to the Special Issue Orthopedic and Trauma Biomechanics)
  • Feature Paper
  • Article
  • Open Access
24 Citations
10,297 Views
24 Pages

18 April 2018

A fractured stainless steel 3.5 mm proximal humerus internal locking system (PHILOS) plate and screws were investigated in this paper. This plate was used for ankle arthrodesis of a 68-year-old female with a right ankle deformity. Both the plate and...

(This article belongs to the Special Issue Failure Analysis of Biometals)
  • Article
  • Open Access
6 Citations
6 Pages

The Use of 2.4-mm Locking Plate System in Treating Comminuted Mandibular Fracture by Firearm

  • Cassiano Costa Silva Pereira,
  • Pâmela Letícia dos Santos,
  • Ellen Cristina Gaetti Jardim,
  • Idelmo Rangel Garcia Júnior and ,
  • Elio Hitoshi Shinohara and
  • Marcelo Marotta Araujo
  • + 1 author+ 0 author

Maxillofacial trauma caused by firearms has considerably increased, in which the mandibular body is the site of highest incidence of firearm projectiles. In these cases, the use of titanium plates and screws allows the early restoration of form and f...

  • Article
  • Open Access
3 Citations
4,143 Views
10 Pages

Optimization of Locking Plate Screw Angle Used to Treat Two-Part Proximal Humerus Fractures to Maintain Fracture Stability

  • Angel D. Castro-Franco,
  • Ismael Mendoza-Muñoz,
  • Alvaro González-Angeles,
  • Mildrend I. Montoya-Reyes and
  • Nun Pitalúa-Díaz

8 May 2022

Proximal humerus fractures increase with the aging of the population. Due to the high failure rates of surgical treatments such as open reduction and internal fixation (ORIF), biomechanical studies seek to optimize the treatments and intervening fact...

  • Article
  • Open Access
7 Citations
2,800 Views
15 Pages

Influence of Screw Angulation on the Mechanical Properties on a Polyaxial Locking Plate Fixation

  • Gabriel Martínez-Fortún,
  • Alejandro Yánez and
  • Alberto Cuadrado

Polyaxial locking systems are widely used for strategic surgical placement, particularly in cases of osteoporotic bones, comminuted fractures, or when avoiding pre-existing prosthetics. However, studies suggest that polyaxiality negatively impacts sy...

(This article belongs to the Section Biomedical Engineering and Biomaterials)
  • Article
  • Open Access
552 Views
18 Pages

The Computational Design of a Novel Anterior Plate for Extra-Articular Distal Humerus Fractures

  • Phachara Suklim,
  • Daisy L. Lang,
  • William K. Durfee,
  • Arthur G. Erdman and
  • Atichart Kwanyuang

Extra-articular distal humerus fractures present surgical challenges, often requiring technically demanding posterior approaches with high radial nerve injury risks or off-label use of anatomically mismatched proximal plates. This study aimed to comp...

(This article belongs to the Topic Biomedical Engineering, Healthcare and Sustainability, 2nd Edition)
  • Article
  • Open Access
1,175 Views
23 Pages

Biomechanical Behavior of Composite Bone–Osteosynthesis Constructs in Complex Proximal Humerus Fractures: A Synergistic Experimental and Finite Element Approach

  • Andrei Scripcaru,
  • Vasile Iulian Antoniac,
  • Mădălina Maria Diac,
  • Mihnea Theodor Sîrbu and ,
  • Tatiana Iov,
  • Veronica Scripcaru,
  • Simona Irina Damian,
  • Diana Bulgaru Iliescu,
  • Norin Forna and
  • Paul-Dan Sîrbu
  • + 5 authors+ 0 author

This study evaluates the mechanical behavior of bone-implant assemblies used in treating complex proximal humerus fractures, a clinical challenge due to the anisotropic nature of bone and variability in patient-specific conditions. The aim of this st...

(This article belongs to the Special Issue Orthopedic and Trauma Biomechanics)
  • Case Report
  • Open Access
4 Citations
8,307 Views
11 Pages

29 January 2023

Background: Various techniques have been reported to treat large, segmental tibial defects, such as autogenous bone graft, vascularized free fibula transfer and bone transport. We present a case of a 24-year-old male with a 17-year history of chronic...

(This article belongs to the Special Issue Current Status and Future Directions of Bone Trauma Surgery)
  • Article
  • Open Access
1,354 Views
15 Pages

Should We Worry About the Inter-Implant Gap in the Tibia? A Finite Element Analysis of Revision TKA and Distal Plating

  • Renato Caravellos Glória,
  • Pedro José Labronici,
  • Anderson Freitas and
  • Vincenzo Giordano

27 February 2026

Background and Objectives: The management of periprosthetic tibial fractures distal to revision Total Knee Arthroplasty (TKA) presents a biomechanical challenge, often requiring extramedullary locking plates when long stems preclude nailing. While in...

(This article belongs to the Special Issue Update on Orthopedic Surgeries of the Lower Extremity Diseases and Injuries: 3rd Edition)
  • Article
  • Open Access
1 Citations
2,643 Views
12 Pages

Adding a fibular strut bone graft to locking plate fixation has been introduced to improve stability and prevent varus collapse. The purpose of this study was to perform finite element analysis (FEA) of the biomechanical characteristics of different...

(This article belongs to the Section Biomechanics and Sports Medicine)
  • Article
  • Open Access
5 Citations
3,007 Views
14 Pages

26 July 2022

This work is about numerical simulations of vortex induced acoustic resonance in a duct, experimentally investigated by Welsh et al. Vortex shedding of low-speed flow over a flat plate excites an acoustic duct mode, leading to a lock-in of shedding a...

  • Article
  • Open Access
3 Citations
2,308 Views
9 Pages

Feasibility of Implant Strain Measurement for Assessing Mandible Bone Regeneration

  • René Marcel Rothweiler,
  • Sergej Zankovic,
  • Leonard Simon Brandenburg,
  • Marc-Anton Fuessinger and ,
  • Christian Gross,
  • Pit Jacob Voss and
  • Marc-Christian Metzger
  • + 2 authors+ 0 author

27 September 2022

Nonunion is one of the most dreaded complications after operative treatment of mandible fractures or after mandible reconstruction using vascularized and non-vascularized bone grafts. Often diagnosis is made at advanced stage of disease when pain or...

(This article belongs to the Section B: Biology and Biomedicine)
  • Article
  • Open Access
8 Citations
3,593 Views
21 Pages

Stability Analysis of Plate—Screw Fixation for Femoral Midshaft Fractures

  • Izzawati Basirom,
  • Ruslizam Daud,
  • Muhammad Farzik Ijaz,
  • Mohd Afendi Rojan and
  • Khairul Salleh Basaruddin

30 August 2023

An understanding of the biomechanical characteristics and configuration of flexible and locked plating in order to provide balance stability and flexibility of implant fixation will help to construct and promote fast bone healing. The relationship be...

(This article belongs to the Special Issue Material, Design and Biological Studies of Bones & Implants)
  • Article
  • Open Access
7 Citations
6,692 Views
12 Pages

Treatment of Canine Disc-Associated Cervical Spondylomyelopathy with a Cervical Distraction–Stabilization Technique (C-LOX Combined with LCP Plate) and Clinical Outcomes

  • Marco Tabbì,
  • Giuseppe Barillaro,
  • Claudia Dina Interlandi,
  • Simona Di Pietro and ,
  • Domenico Fugazzotto,
  • Giovanna Lucrezia Costa,
  • Nicola Maria Iannelli,
  • Daniele Macrì,
  • Vincenzo Ferrantelli and
  • Francesco Macrì
  • + 5 authors+ 0 author

8 August 2023

Canine disc-associated cervical spondylomyelopathy (DA-CSM) is a form of caudal CSM, characterized by the compression of the spinal cord and nerve roots due to an intervertebral disc protrusion. It is more frequent in large canine breeds. A variety o...

(This article belongs to the Special Issue Diagnostic Approach and Treatment of Orthopedic Disease in Dogs and Cats)
  • Article
  • Open Access
8 Citations
2,327 Views
9 Pages

Biomechanical Comparison of Medio-Plantar and Plantar Plate Fixation for First Tarsometatarsal Joint Arthrodesis

  • Kajetan Klos,
  • Paul Simons,
  • Pauline Schopp,
  • Philipp Schenk and ,
  • Felix C. Kohler,
  • Akram Uddin,
  • Edgar K. Roth,
  • Uta Biedermann,
  • Gunther O. Hofmann and
  • Mark Lenz
  • + 5 authors+ 0 author

7 June 2023

Plantar plate positioning has been demonstrated as biomechanically superior. However, some operators remain resentful about the morbidity of the surgical approach. To provide improved plate fixation for first tarsometatarsal joint arthrodesis with re...

(This article belongs to the Special Issue Updates in the Orthopedic Management of Foot Disorders)
  • Article
  • Open Access
3 Citations
8,770 Views
8 Pages

Locked Intramedullary Nailing versus Compression Plating for Stable Ulna Fractures: A Comparative Study

  • Vito Pavone,
  • Marco Ganci,
  • Giacomo Papotto,
  • Giuseppe Mobilia and ,
  • Umberto Sueri,
  • Alpesh Kothari,
  • Andrea Vescio and
  • Gianluca Testa
  • + 3 authors+ 0 author

Background: Isolated ulna shaft fractures (USFs) are a relatively uncommon, but significant, injury. For unstable USF treatment, open reduction and internal fixation (ORIF) is the gold standard, while for stable USFs several procedures were described...

(This article belongs to the Special Issue Fractures Management in Upper and Lower Limbs)
  • Article
  • Open Access
5 Citations
3,222 Views
16 Pages

Assessment of Gait Following Locking Plate Fixation of a Tibial Segmental Defect and Cast Immobilization in Goats

  • Kristin M. Bowers,
  • Lori D. Terrones,
  • Elizabeth G. Croy,
  • Pierre-Yves Mulon and ,
  • Henry S. Adair and
  • David E. Anderson
  • + 1 author+ 0 author

2 November 2022

The purpose of this study was to analyze the effects of locking plate fixation used for bridging of tibial segmental ostectomy and of cast immobilization on gait biomechanics in goats. We hypothesized that stable fixation of a segmental bone defect,...

(This article belongs to the Section Gait and Posture Biomechanics)
  • Article
  • Open Access
1 Citations
1,018 Views
10 Pages

Biomechanical Analysis of Micromotion of Proximal Interphalangeal Joint Arthrodeses During Activities of Daily Life In Vitro

  • Michael Millrose,
  • Till Ittermann,
  • Hans Christoph Vonderlind,
  • Maximilian Willauschus and ,
  • Johannes Rüther,
  • Hermann-Josef Bail and
  • Markus Geßlein
  • + 2 authors+ 0 author

21 June 2025

Background/Objectives: Proximal interphalangeal joint (PIJ) arthrodesis is a common surgical intervention for patients with PIJ osteoarthritis or trauma-related joint destruction. The objective of this study was to evaluate the biomechanical stabilit...

(This article belongs to the Special Issue State of the Art in Hand Surgery)
  • Article
  • Open Access
7 Citations
2,689 Views
9 Pages

Comparison of Three Internal Fixation Constructs for AO/OTA 33-A3 Distal Femoral Fractures: A Biomechanical Study

  • Wei Xie,
  • Hui Liu,
  • Shufen Chen,
  • Weizhen Xu and ,
  • Weibin Lin,
  • Tianlai Chen,
  • Lingqi Zhu,
  • Wenliang Zhai and
  • Jin Wu
  • + 4 authors+ 0 author

Background: To compare the biomechanical performance of three internal fixation constructs for AO/OTA 33-A3 distal femoral fractures. Methods: Thirty AO/OTA 33-A3 synthetic distal femoral fracture models were constructed and randomly divided into thr...

(This article belongs to the Special Issue Biomechanics of Orthopaedic Rehabilitation)
  • Article
  • Open Access
4 Citations
2,692 Views
12 Pages

Biomechanical Efficacy of Three Methods for the Fixation of Posterior Malleolar Fractures: A Three-Dimensional Finite Element Study

  • Vincenzo Giordano,
  • Márcio Antônio Babinski,
  • Anderson Freitas,
  • Robinson Esteves Pires and ,
  • Felipe Serrão de Souza,
  • Luiz Paulo Giorgetta de Faria,
  • Pedro José Labronici and
  • Alexandre Godoy-Santos
  • + 3 authors+ 0 author

24 November 2023

Introduction: We investigated the biomechanical behaviour of different fixations of the tibial posterior malleolus (TPM), simulating distinct situations of involvement of the tibiotalar articular surface (TTAS) through a finite element model (FEM). M...

(This article belongs to the Special Issue Imaging Diagnosis of Foot and Ankle Injuries)
  • Article
  • Open Access
6 Citations
2,812 Views
14 Pages

Extra-Articular Distal Humerus Plate 3D Model Creation by Using the Method of Anatomical Features

  • Nikola Vitković,
  • Jelena R. Stojković,
  • Nikola Korunović,
  • Emil Teuţan and ,
  • Alin Pleşa,
  • Alexandru Ianoşi-Andreeva-Dimitrova,
  • Filip Górski and
  • Răzvan Păcurar
  • + 3 authors+ 0 author

2 August 2023

Proper fixation techniques are crucial in orthopedic surgery for the treatment of various medical conditions. Fractures of the distal humerus can occur due to either high-energy trauma with skin rupture or low-energy trauma in osteoporotic bone. The...

(This article belongs to the Section Manufacturing Processes and Systems)
  • Article
  • Open Access
2 Citations
3,148 Views
9 Pages

Risk Factors of Proximal Screw Breakage of Locking Plate (ZPLP®) after MIPO for Distal Femur Fractures -Analysis of Patients with Plate Removal after Bony Union-

  • Jehyun Yoo,
  • Daekyung Kwak,
  • Joongil Kim,
  • Seungcheol Kwon and ,
  • Junhyuk Kwon and
  • Jihyo Hwang
  • + 1 author+ 0 author

3 October 2023

Background: Locking a compression plate is a more favorable surgical technique than intramedullary nailing in the treatment of distal femur fractures. This study analyzed the risk factors of proximal screw breakage retrospectively, which was confirme...

(This article belongs to the Special Issue Orthopaedic Trauma Surgery: Diagnosis, Treatment and Outcome)
  • Article
  • Open Access
1 Citations
6,889 Views
10 Pages

13 October 2021

Purpose: Operative therapy for unstable lateral clavicle fractures is necessary to reduce the risk of bony non-union. Irritation and restriction during sportive activities due to the implanted materials are a common reason for impaired function and i...

(This article belongs to the Section Orthopedics)
  • Systematic Review
  • Open Access
5 Citations
3,467 Views
14 Pages

5 July 2024

Background/Objectives: Intramedullary screw fixation (IMS) and locking plate fixation (LPF) are currently recommended treatments for proximal fifth metatarsal fractures (PFMF). However, treating comminuted or small displaced avulsion PFMF with IMS po...

(This article belongs to the Special Issue Evidence-Based Medicine in the Practice of Orthopedics and Trauma Care: Current Status and Future Challenges)
  • Article
  • Open Access
1 Citations
3,461 Views
9 Pages

22 August 2024

Background and Objectives: Anterior sacroiliac fracture dislocation (ASFD), also known as locked pelvis, is a rarely reported diagnosis. The types of ASFDs are often misdiagnosed as lateral compression fractures due to the presence of crescent f...

(This article belongs to the Section Surgery)
  • Article
  • Open Access
3 Citations
1,729 Views
22 Pages

30 June 2025

Biodegradable magnesium-based composites show potential application in orthopedic implants, with excellent biocompatibility, low density, and biodegradable characteristics inside the human body. In this study, the stir casting procedure was employed...

(This article belongs to the Section Materials Processes)
  • Proceeding Paper
  • Open Access
1 Citations
2,731 Views
18 Pages

Reliability Design of Mechanical Systems Such as Compressor Subjected to Repetitive Stresses

  • Seongwoo Woo,
  • Dennis L. O’Neal,
  • Samson Mekbib Atnaw and
  • Muluneh Mekonnen Tulu

20 February 2021

This paper suggests parametric accelerated life testing (ALT) as a systematic reliability technique to generate the reliability quantitative (RQ) specification such as mission cycle for identifying design flaws in mechanical systems as exerting the a...

(This article belongs to the Proceedings of The 1st International Electronic Conference on Metallurgy and Metals)
  • Article
  • Open Access
2 Citations
2,458 Views
11 Pages

30 September 2023

In this work, we present ultrashort pulse generation from passively mode-locked Cr:ZnS laser with a monolayer graphene-coated ZnSe substrate exhibiting high nonlinearity. The femtosecond Cr:ZnS laser produces output power up to 330 mW at a 233 MHz re...

(This article belongs to the Section Lasers, Light Sources and Sensors)
  • Article
  • Open Access
8 Citations
2,976 Views
13 Pages

22 August 2024

The commonly used aluminum–copper alloys in industry are mainly rolled plates and extruded or drawn bars. The aluminum–copper alloys’ anisotropy generated in the manufacturing process is unfavorable for subsequent applications. Its...

(This article belongs to the Section Mechanics of Materials)
  • Article
  • Open Access
10 Citations
4,738 Views
21 Pages

10 August 2021

This study demonstrates the use of parametric accelerated life testing (ALT) as a way to recognize design defects in mechanical products in creating a reliable quantitative (RQ) specification. It covers: (1) a system BX lifetime that X% of a product...

(This article belongs to the Special Issue Selected Papers from the 1st International Electronic Conference on Metallurgy and Metals (IEC2M 2021))
  • Article
  • Open Access
5 Citations
5,042 Views
10 Pages

Primary Radial Nerve Lesions in Humerus Shaft Fractures—Revision or Wait and See

  • Alexander Böhringer,
  • Raffael Cintean,
  • Konrad Schütze and
  • Florian Gebhard

25 March 2024

Background: This study investigates the surgical state-of-the-art procedure for humeral shaft fractures with primary radial nerve palsy based on its own case series in relation to the current and established literature. Methods: Retrospective review...

(This article belongs to the Special Issue Orthopedic Diseases and Traumatology: Surgical Treatment and Rehabilitation)
  • Article
  • Open Access
16 Citations
13,236 Views
20 Pages

The Effect of External Fixator Configurations on the Dynamic Compression Load: An Experimental and Numerical Study

  • Ana Martins Amaro,
  • Maria Fátima Paulino,
  • Luis Manuel Roseiro and
  • Maria Augusta Neto

18 December 2019

(1) Objective: External fixation systems are commonly used by surgeons to ensure stabilization and consolidation of bone fractures, especially in patients who are at high risk for systematic complications. Both rigid and elastic external fixations ar...

(This article belongs to the Special Issue Applied Biomechanics in Sport, Rehabilitation and Ergonomy)
  • Review
  • Open Access
1 Citations
4,349 Views
28 Pages

Matrix WaveTM System for Mandibulo-Maxillary Fixation—Just Another Variation on the MMF Theme? Part I: A Review on the Provenance, Evolution and Properties of the System

  • Carl-Peter Cornelius,
  • Paris Georgios Liokatis,
  • Timothy Doerr,
  • Damir Matic and ,
  • Stefano Fusetti,
  • Michael Rasse,
  • Nils Claudius Gellrich,
  • Max Heiland,
  • Warren Schubert and
  • Daniel Buchbinder
  • + 5 authors+ 0 author

Study design: The advent of the Matrix WaveTM System (Depuy-Synthes)—a bone-anchored Mandibulo-Maxillary Fixation (MMF) System—merits closer consideration because of its peculiarities. Objective: This study alludes to two preliminary stag...

  • Article
  • Open Access
999 Views
14 Pages

Effects of Advanced Platelet-Rich Fibrin on Bone Healing in the Treatment of Canine Appendicular Fractures

  • Ravisa Warin,
  • Preeyanat Vongchan,
  • Witaya Suriyasathaporn,
  • Ratchadaporn Boripun and ,
  • Kanawee Warrit,
  • Luddawon Somrup,
  • Kittidaj Tanongpitchayes,
  • Pimnipa Jieraviriyapun and
  • Wanna Suriyasathaporn
  • + 4 authors+ 0 author

21 April 2026

Although internal fixation and surgical approaches promote fracture healing, some outcomes remain unsatisfactory. Advanced platelet-rich fibrin (A-PRF) has been shown to provide more growth factors, and in vitro cell proliferation has not been evalua...

(This article belongs to the Special Issue Advanced Management of Small Animal Fractures)
  • Article
  • Open Access
10 Citations
6,229 Views
8 Pages

Lateral malleolus fracture is one of the most common fractures. However, there is controversy regarding the rehabilitation protocols used after surgery. In particular, the initiation point for weight-bearing has not been standardized. In the present...

(This article belongs to the Special Issue Lower Extremity Diseases, Injuries and Public Health)
  • Article
  • Open Access
21 Citations
8,762 Views
21 Pages

Fixation Release and the Bone Bandaid: A New Bone Fixation Device Paradigm

  • Narges Shayesteh Moghaddam,
  • Ahmadreza Jahadakbar,
  • Amirhesam Amerinatanzi,
  • Roman Skoracki and ,
  • Michael Miller,
  • David Dean and
  • Mohammad Elahinia
  • + 2 authors+ 0 author

The current gold standard of care for mandibular segmental defeat reconstruction is the use of Ti-6Al-4V immobilization hardware and fibular double barrel graft. This method is often successful immediately at restoring mandible function, however the...

(This article belongs to the Special Issue Advances in 3D Printing of Biomaterials)
  • Article
  • Open Access
13 Citations
5,311 Views
16 Pages

10 May 2019

Because of the constant northward movement of the Indian plate and blockage of the Eurasian continent, the Qinghai–Tibet Plateau has been extruded by north–south compressive stresses since its formation. This has caused the plateau to esc...

(This article belongs to the Special Issue Environmental and Geodetic Monitoring of the Tibetan Plateau)
  • Case Report
  • Open Access
611 Views
13 Pages

Bilateral Stifle Arthrodesis as a Salvage Procedure for End-Stage Bilateral Grade IV Lateral Patellar Luxation in a Dog: A Case Report

  • Ciprian Ober,
  • Vasile Coza,
  • Ballai Szidónia,
  • Bogdan Tancău and ,
  • Christos Yiapanis,
  • William McCartney,
  • Denis Gaceu,
  • Ștefana Mureșan,
  • Maria Moraru and
  • Bianca Boldiș
  • + 5 authors+ 0 author

Grade IV lateral patellar luxation is an advanced orthopedic condition that may be associated with severe skeletal deformities, chronic soft-tissue contracture, and irreversible loss of normal stifle function. Although reconstructive procedures are c...

(This article belongs to the Section Veterinary Surgery)