Skip to Content

822 Results Found

  • Article
  • Open Access
14 Citations
5,052 Views
13 Pages

22 May 2021

This paper presents a series of experiments on the effectiveness of existing mechanical ventilation systems during accidental hydrogen releases in confined spaces, such as underground garages. The purpose was to find the mass flow rate limit, hence t...

(This article belongs to the Collection Women in Hydrogen Energy)
  • Article
  • Open Access
3 Citations
3,422 Views
21 Pages

Parameter Selection for the Dehumidification System of the Main Cable of Suspension Bridge Based on Ventilation Experiments

  • Zhihang Guo,
  • Wenhao Sui,
  • Hua Guan,
  • Pei Peng and ,
  • Qun Liu and
  • Jianzhong Shi
  • + 1 author+ 0 author

Moisture in the main cable is the main cause of steel wire corrosion. Modern suspension bridges utilize main cable dehumidification systems to prevent corrosion. The main cable ventilation experiment can help the selection of the system parameters. T...

(This article belongs to the Special Issue AI and Data Analytics for Energy-Efficient and Healthy Buildings)
  • Article
  • Open Access
13 Citations
7,221 Views
11 Pages

The unique architectural style of traditional “Yinzi” dwellings in Western Hunan, China, needs to be protected and their natural ventilation of patio space should also be promoted. Therefore, this study aimed at finding out the natural ventilation va...

(This article belongs to the Special Issue Sustainable Building in Rural Areas)
  • Article
  • Open Access
10 Citations
5,220 Views
11 Pages

Objective: The objective of this study is to explore the experiences of patients who received mechanical ventilation (MV) support during their intensive care unit (ICU) stay in Jordan. Methods: A phenomenological hermeneutic approach was conducted, i...

  • Feature Paper
  • Article
  • Open Access
1 Citations
2,369 Views
17 Pages

With increases in the time spent on indoor activities, the interests and technological demands regarding indoor air quality (IAQ) have also increased. Indoor air pollution is often caused by furniture or construction materials and chemical substances...

(This article belongs to the Special Issue Risk Analysis Method and Model of Pollutants)
  • Article
  • Open Access
6 Citations
2,241 Views
13 Pages

28 November 2023

The ventilation system is the only channel for gas exchange inside and outside the gas tunnel, which determines whether the high-risk gas in the tunnel can be exhausted in time after a gas leakage accident; thus, it is essential to study the dynamic...

(This article belongs to the Section Civil Engineering)
  • Article
  • Open Access
1 Citations
1,140 Views
13 Pages

23 December 2025

Asymmetric V-shaped tunnels are commonly found in newly built urban underground road tunnels. In such kinds of tunnels, the flow of smoke becomes very complicated in the event of a fire, and effective smoke control under longitudinal ventilation is c...

(This article belongs to the Special Issue Modeling, Experiment and Simulation of Tunnel Fire)
  • Article
  • Open Access
1 Citations
1,102 Views
19 Pages

17 February 2026

This study evaluates the feasibility of continuous indoor pollutant monitoring as an indirect method for assessing extended ventilation performance in residential buildings. This research addresses key limitations of conventional short-term tracer-ga...

(This article belongs to the Section Air Pollution Control)
  • Article
  • Open Access
2 Citations
1,598 Views
12 Pages

20 April 2025

The objective of this study was to understand the characteristics of gas migration in a mine system network domain during a period of reversal ventilation. Combining field experiments with the TF1M3D simulation program, we analyzed gas migration and...

  • Article
  • Open Access
12 Citations
6,859 Views
15 Pages

17 March 2016

The efficient operation of a passive solar house requires an efficient ventilation system to prevent the loss of energy and provide the required ventilation rates. This paper proposes the use of “breathing architectural members” (BAMs) as passive nat...

(This article belongs to the Special Issue Energy Efficient Actuators and Systems)
  • Article
  • Open Access
9 Citations
2,435 Views
19 Pages

Study on the Influence of High-Altitude Helical Tunnel Curvature on Jet Fan Spatial Layout

  • Zijian Wang,
  • Qi Liu,
  • Hao Li,
  • Bin Zhang and ,
  • Liming Wu,
  • Sichang Wang and
  • Chaolin Jia
  • + 2 authors+ 0 author

During the operational ventilation process of high-altitude helical tunnels, the installation method of jet fans is a key factor in determining the ventilation efficiency of the tunnel. In this study, the CFD numerical simulation method is adopted to...

(This article belongs to the Section Building Energy, Physics, Environment, and Systems)
  • Article
  • Open Access
3 Citations
3,792 Views
13 Pages

The Impact of Decreased Atmospheric Pressure on Forced Aeration of Discharged Flow

  • Yijiao Guo,
  • Luchen Zhang,
  • Lei Yu,
  • Shaoze Luo and ,
  • Chuang Liu and
  • Yuan Liu
  • + 1 author+ 0 author

21 January 2024

To account for changes in the performance of spillway aerator structures of high-altitude dams, depressurization generalized model experiments and theoretical analyses were conducted in this study. Measurements were taken for ventilation hole air vel...

(This article belongs to the Special Issue Advanced Research on Hydraulic Engineering and Hydrological Modelling)
  • Article
  • Open Access
6 Citations
3,021 Views
21 Pages

Although research on the natural ventilation of single-sided buildings is progressing, research on the natural ventilation of the Mogao Grottoes, which have special shapes and structures, is relatively limited. The purpose of this paper is to develop...

(This article belongs to the Section Building Energy, Physics, Environment, and Systems)
  • Article
  • Open Access
13 Citations
4,109 Views
13 Pages

Safe Ventilation Methods against Leaks in Hydrogen Fuel Cell Rooms in Homes

  • Hyon Wook Ji,
  • Hongcheol Lee,
  • Inju Hwang and
  • Heela Jang

27 July 2022

Hydrogen, which has a high energy density and does not emit pollutants, is considered an alternative energy source to replace fossil fuels. Herein, we report an experimental study on hydrogen leaks and ventilation methods for preventing damage caused...

(This article belongs to the Section G: Energy and Buildings)
  • Article
  • Open Access
4 Citations
2,185 Views
14 Pages

29 June 2024

The disorder and disaster evolution characteristics of ascensional airflow fires in mine ventilation systems has been the focus of mine fire research. In this work, through repeated experiments, the variation characteristics of the temperature and ai...

(This article belongs to the Section Fire Risk Assessment and Safety Management in Buildings and Urban Spaces)
  • Article
  • Open Access
4 Citations
5,513 Views
17 Pages

Ventilation ducts with a high cross-sectional area are frequently built as structural ducts that include inside transversal structural beams. In this way, the cross-sectional area requested is respected, but the transverse structural elements will ha...

(This article belongs to the Special Issue Marine Renewable Energy and the Transition to a Low Carbon Future)
  • Article
  • Open Access
526 Views
24 Pages

6 August 2026

Longitudinal ventilation is a primary smoke-control strategy in road tunnels, yet its effect on structural thermal exposure remains insufficiently quantified under full-scale conditions. This study examined whether increased airflow mitigates lining...

(This article belongs to the Special Issue Tunnel Fire Behavior: Dynamics, Smoke Management, and Safety Strategies)
  • Article
  • Open Access
9 Citations
2,947 Views
20 Pages

9 December 2021

Statistics show that most fires occur in civil residential buildings. Most casualties are due to the inhalation of hot air loaded with smoke, leading to intoxication with substances harmful to the human body. This research aimed to develop a CFD mode...

(This article belongs to the Special Issue Urban Sustainability and Resilience of the Built Environments)
  • Article
  • Open Access
8 Citations
3,534 Views
20 Pages

Experimental Study of Wind Pressures on Low-Rise H-Shaped Buildings

  • Talita Andrioli Medinilha-Carvalho,
  • Fernando Vítor Marques da Silva,
  • Facundo Bre,
  • Juan M. Gimenez and
  • Lucila Chebel Labaki

Recognizing the urgent need for mitigating global warming, natural ventilation presents a potential strategy to reduce cooling energy demands, enhance thermal comfort, and contribute to indoor air quality. H-shaped buildings are prevalent worldwide,...

(This article belongs to the Special Issue Ventilation and Air Distribution Systems in Buildings)
  • Article
  • Open Access
3 Citations
3,992 Views
19 Pages

27 January 2022

Natural smoke control systems in staircases are one of the available systems used for the protection of escape routes from smoke and are one of the most utilised for medium to high rise buildings. However, their effectiveness (as well as other ventil...

(This article belongs to the Topic Sustainable Built Environment)
  • Article
  • Open Access
2 Citations
2,376 Views
17 Pages

Study on Performance of Coordinated Ventilation Strategies during T-Shaped Subway Station Hall Fire

  • Yanan Hou,
  • Wei Ding,
  • Zhengbo Hou,
  • Xingcheng Li and ,
  • Ling Li,
  • Zhihao Yang and
  • Congling Shi
  • + 2 authors+ 0 author

29 January 2025

A subway transfer station hall is crowded and complex in structure, which makes evacuation more difficult in case of a fire, but also provides more strategic options for smoke extraction. Full-scale experiments and numerical simulations are conducted...

(This article belongs to the Special Issue Dynamics of Wind-Fire Interaction: Fundamentals and Applications)
  • Article
  • Open Access
5 Citations
3,677 Views
11 Pages

9 January 2021

Understanding the characteristics of natural, wind-induced ventilation of buildings is essential for accurate predictions of ventilation flow rates; however, indoor ventilation is significantly influenced by surrounding buildings. Therefore, a series...

(This article belongs to the Special Issue Sustainable Urban Environment and Building Energy Efficiency)
  • Article
  • Open Access
13 Citations
7,598 Views
26 Pages

Reengineering Indoor Air Quality Monitoring Systems to Improve End-User Experience

  • Radu Nicolae Pietraru,
  • Adriana Olteanu,
  • Ioana-Raluca Adochiei and
  • Felix-Constantin Adochiei

22 April 2024

This paper presents an indoor air quality (IAQ) monitoring system designed for a better end-user experience. The monitoring system consists of elements, from the monitoring sensor to the monitoring interface, designed and implemented by the research...

(This article belongs to the Special Issue Internet of Things and Sensor Technologies in Smart Agriculture)
  • Feature Paper
  • Article
  • Open Access
33 Citations
5,145 Views
18 Pages

12 April 2019

Smoke control is a crucial issue in a long-distance subway tunnel fire, and a two-point extraction ventilation system is an effective way to solve this problem, due to the characteristics of controlling the smoke in a limited area and removing high-t...

(This article belongs to the Section J: Thermal Management)
  • Article
  • Open Access
19 Citations
5,379 Views
24 Pages

Mixed-mode cooling can effectively reduce the energy consumption of building cooling while satisfying the thermal comfort of occupancy and indoor air quality requirements. This paper predicted the thermal performance and energy-saving potential of an...

(This article belongs to the Section Building Energy, Physics, Environment, and Systems)
  • Article
  • Open Access
18 Citations
6,547 Views
31 Pages

Development of an Air-Recirculated Ventilation System for a Piglet House, Part 1: Analysis of Representative Problems through Field Experiment and Aerodynamic Analysis Using CFD Simulation for Evaluating Applicability of System

  • Jun-gyu Kim,
  • In-bok Lee,
  • Sang-yeon Lee,
  • Se-jun Park and ,
  • Deuk-young Jeong,
  • Young-bae Choi,
  • Cristina Decano-Valentin and
  • Uk-hyeon Yeo
  • + 3 authors+ 0 author

As the pig industry develops rapidly, various problems are appearing both inside and outside the pig houses. In particular, in the case of pig houses, it is difficult to solve the main problems even if automation and mechanization are applied with IC...

(This article belongs to the Section Farm Animal Production)
  • Article
  • Open Access
25 Citations
3,952 Views
13 Pages

15 June 2018

In the present work, an industrial-scale experiment on ventilation air methane (VAM) utilization by a multibed thermal flow-reversal reactor (TFRR) is conducted in China. The influence of the inlet flow rate, feed methane concentration, and cycle tim...

  • Article
  • Open Access
1 Citations
852 Views
19 Pages

Research on Alarm Interface of Virtual Monitoring System for Ventilation Control in Flotation Workshop Based on Cognitive Load Theory

  • Jiang Shao,
  • Zhi-Yong Chen,
  • Shang-Song Jiang,
  • Han-Yu Feng and ,
  • Yu-Peng Li and
  • Guo-Ping Ma
  • + 1 author+ 0 author

28 February 2026

Flotation workshop ventilation control virtual monitoring system alarm interfaces need to adapt to high-dynamic and high-interference industrial environments, while traditional interfaces have information overload and chaotic layout, leading to exces...

(This article belongs to the Special Issue Human-Centered Design in Wearable Technology)
  • Article
  • Open Access
191 Views
28 Pages

8 October 2026

Field temperature and elevation records from a G219 crushed-rock ventilated embankment show transverse differences, but the available spring observations do not cover a complete thaw-peak-to-recovery sequence. We used these records to constrain the s...

(This article belongs to the Section Energy Systems)
  • Article
  • Open Access
1 Citations
3,178 Views
8 Pages

29 November 2021

High-frequency oscillatory ventilation (HFOV) is a type of mechanical ventilation with a protective potential characterized by a small tidal volume. Unfortunately, HFOV has limited monitoring of ventilation parameters and mechanical parameters of the...

  • Article
  • Open Access
16 Citations
4,496 Views
18 Pages

31 May 2021

As the gymnasiums in subtropical region with hot and humid climate are naturally ventilated during non-competition periods, occupants exercising indoors often feel uncomfortable, especially in summer. In order to provide thermally comfortable and hea...

(This article belongs to the Section G: Energy and Buildings)
  • Article
  • Open Access
13 Citations
9,729 Views
33 Pages

11 February 2021

Displacement ventilation is a proven method of providing conditioned air to enclosed spaces with the aim to deliver good air quality and thermal comfort while reducing the amount of energy required to operate the system. Until now, the practical appl...

(This article belongs to the Special Issue Sustainable Buildings: Heating, Ventilation and Air-Conditioning)
  • Article
  • Open Access
4 Citations
3,239 Views
19 Pages

Health System Factors Affecting the Experience of Non-Invasive Ventilation Provision of People with Neuromuscular Disorders in New Zealand

  • Meredith A. Perry,
  • Bernadette Jones,
  • Matthew Jenkins,
  • Hemakumar Devan and ,
  • Alister Neill and
  • Tristram Ingham
  • + 1 author+ 0 author

Non-invasive ventilation (NIV) is a critical therapy for many patients with neuromuscular disorders (NMD), supporting those with respiratory failure to achieve adequate respiration and improve their quality of life. The aim of this study was to explo...

(This article belongs to the Section Health Care Sciences & Services)
  • Article
  • Open Access
10 Citations
2,981 Views
20 Pages

Influence of the Positive Pressure Ventilator Setting Distance in Front of the Doorway on the Effectiveness of Tactical Mechanical Ventilation in a Multistory Building

  • Piotr Kaczmarzyk,
  • Łukasz Warguła,
  • Piotr Krawiec,
  • Paweł Janik and ,
  • Rafał Noske and
  • Wojciech Klapsa
  • + 1 author+ 0 author

29 April 2023

Proper positioning of the positive pressure ventilator is an important aspect of conducting rescue operations. The purpose of this article was to determine the effect of the parameter of the distance of setting up a mobile fan (distance from 1 to 7 m...

  • Article
  • Open Access
4 Citations
5,234 Views
17 Pages

Miniaturization of Respiratory Measurement System in Artificial Ventilator for Small Animal Experiments to Reduce Dead Space and Its Application to Lung Elasticity Evaluation

  • Homare Yoshida,
  • Yoshihiro Hasegawa,
  • Miyoko Matsushima,
  • Tomoshi Sugiyama and ,
  • Tsutomu Kawabe and
  • Mitsuhiro Shikida
  • + 1 author+ 0 author

28 July 2021

A respiratory measurement system composed of pressure and airflow sensors was introduced to precisely control the respiratory condition during animal experiments. The flow sensor was a hot-wire thermal airflow meter with a directional detection and a...

(This article belongs to the Section Biomedical Sensors)
  • Article
  • Open Access
4 Citations
2,140 Views
21 Pages

1 October 2025

In greenhouse and plant factory production, improper design of the ventilation system and increasing scales will lead to a stagnant airflow zone, which could inhibit plant growth and induce physiological disease, such as tipburn. To increase the airf...

(This article belongs to the Topic Optimizing Plants and Cultivation System for Controlled Environment Agriculture (CEA))
  • Review
  • Open Access
20 Citations
5,777 Views
24 Pages

Patient Experience in Home Respiratory Therapies: Where We Are and Where to Go

  • Cátia Caneiras,
  • Cristina Jácome,
  • Sagrario Mayoralas-Alises,
  • José Ramon Calvo and ,
  • João Almeida Fonseca,
  • Joan Escarrabill and
  • João Carlos Winck
  • + 2 authors+ 0 author

24 April 2019

The increasing number of patients receiving home respiratory therapy (HRT) is imposing a major impact on routine clinical care and healthcare system sustainability. The current challenge is to continue to guarantee access to HRT while maintaining the...

(This article belongs to the Special Issue Clinical Medicine for Healthcare and Sustainability)
  • Article
  • Open Access
10 Citations
2,717 Views
13 Pages

Characteristics of Airflow Reversal of Excavation Roadway after a Coal and Gas Outburst Accident

  • Junhong Si,
  • Lin Li,
  • Jianwei Cheng,
  • Yiqiao Wang and ,
  • Wei Hu,
  • Tan Li and
  • Zequan Li
  • + 2 authors+ 0 author

18 June 2021

Determining the influence scope of the airflow disorder is an important problem after coal and gas outburst accidents in ventilation systems. This paper puts forward the indexes of airflow disorder, including the length of the excavation roadway, the...

(This article belongs to the Collection The State of the Art of Geo-Energy Technology in China)
  • Article
  • Open Access
2 Citations
3,183 Views
16 Pages

22 October 2024

The construction industry, a significant contributor to global energy consumption and greenhouse gas emissions, is under considerable pressure to adopt transformative approaches. Public buildings, which account for a substantial portion of total ener...

(This article belongs to the Special Issue Traditional Construction Wisdom in Developing Regions: Sustainable Urbanization and Local-Eco Adaptation)
  • Article
  • Open Access
4 Citations
2,447 Views
21 Pages

5 August 2024

Effective fire prevention in mine workings and tunnels requires a thorough theoretical analysis of the heat and mass transfer processes within these structures. This involves using established models to calculate non-isothermal air flow dynamics in l...

  • Article
  • Open Access
14 Citations
14,029 Views
13 Pages

A New Trans-Tympanic Microphone Approach for Fully Implantable Hearing Devices

  • Seong Tak Woo,
  • Dong Ho Shin,
  • Hyung-Gyu Lim,
  • Ki-Woong Seong and ,
  • Peter Gottlieb,
  • Sunil Puria,
  • Kyu-Yup Lee and
  • Jin-Ho Cho
  • + 3 authors+ 0 author

9 September 2015

Fully implantable hearing devices (FIHDs) have been developed as a new technology to overcome the disadvantages of conventional acoustic hearing aids. The implantable microphones currently used in FIHDs, however, have difficulty achieving high sensit...

(This article belongs to the Section Physical Sensors)
  • Article
  • Open Access
63 Citations
9,014 Views
22 Pages

Pedestrian-Level Urban Wind Flow Enhancement with Wind Catchers

  • Lup Wai Chew,
  • Negin Nazarian and
  • Leslie Norford

25 August 2017

Dense urban areas restrict air movement, causing airflow in urban street canyons to be much lower than the flow above buildings. Boosting near-ground wind speed can enhance thermal comfort in warm climates by increasing skin convective heat transfer....

(This article belongs to the Special Issue Recent Advances in Urban Ventilation Assessment and Flow Modelling)
  • Article
  • Open Access
15 Citations
8,522 Views
20 Pages

8 January 2013

In this paper, experimental tests conducted on a new wood-based air-heating system for energy-efficient dwellings are presented. The main objective is to evaluate the resulting outlet temperatures and the amount of heat recovered by the ventilation a...

(This article belongs to the Special Issue Energy Efficient Buildings and Green Buildings)
  • Article
  • Open Access
2,229 Views
24 Pages

16 April 2026

Traditional road tunnel ventilation systems suffer from high energy consumption and limited effectiveness in fire smoke control. Thus, there is a pressing need to develop advanced air purification technologies that integrate low energy demand with ef...

  • Article
  • Open Access
7 Citations
6,606 Views
22 Pages

Effect of Wind Speed on the Natural Ventilation and Smoke Exhaust Performance of an Optimized Unpowered Ventilator

  • Mao Li,
  • Yukai Qiang,
  • Xiaofei Wang,
  • Weidong Shi and ,
  • Yang Zhou and
  • Liang Yi
  • + 1 author+ 0 author

28 January 2022

Natural ventilators can maintain the ventilation of buildings and tunnels, and can exhaust fire smoke without requiring energy. In this study, we optimized a natural ventilator by adding axial fan blades (equivalent to adding a fan system) to investi...

(This article belongs to the Special Issue Fire-Induced Smoke Movement and Control)
  • Article
  • Open Access
10 Citations
4,429 Views
22 Pages

Quantifying Fenestration Effect on Thermal Comfort in Naturally Ventilated Classrooms

  • Ibrahim Reda,
  • Raouf N. AbdelMessih,
  • Mohamed Steit and
  • Ehab M. Mina

1 July 2021

This study seeks to evaluate thermal comfort in naturally ventilated classrooms to draw sustainable solutions that reduce the dramatic energy consumed in mechanically ventilated spaces. Passive ventilation scenarios are generated using alternations o...

(This article belongs to the Collection Sustainability and Engineering Design)
  • Article
  • Open Access
7 Citations
11,680 Views
11 Pages

20 March 2023

Background and objectives: Patients who require prolonged mechanical ventilation typically experience poor long-term survival outcomes. However, there have been few studies conducted to investigate the five-year survival rate of these patients. This...

(This article belongs to the Section Pulmonology)
  • Article
  • Open Access
8 Citations
1,916 Views
20 Pages

Subjective Perception and Cooling Effect for Dynamic Ventilation with Fluctuating Air Velocity

  • Chunfeng Lao,
  • Jing Ling,
  • Jing Li,
  • Jinghua Jiang and ,
  • Sheng Zhang,
  • Yan Yan,
  • Yue Yin and
  • Mingliang Gu
  • + 3 authors+ 0 author

14 August 2025

Dynamic ventilation has proven effective in enhancing indoor thermal comfort. However, previous studies often expose participants to inconsistent thermal environments, potentially compromising the accuracy of subjective evaluations. To address this l...

(This article belongs to the Special Issue Development of Indoor Environment Comfort)
  • Article
  • Open Access
3 Citations
3,030 Views
20 Pages

Experiment and Simulation on a Refrigeration Ventilation System for Deep Metal Mines

  • Wei Shao,
  • Shuo Wang,
  • Wenpu Wang,
  • Kun Shao and ,
  • Qi Xiao and
  • Zheng Cui
  • + 1 author+ 0 author

10 May 2023

Significant harm from heat has become a key restriction for deep metal mining with increasing mining depth. This paper proposes a refrigeration ventilation system for deep metal mines combined with an existing air cycling system and builds an experim...

(This article belongs to the Special Issue Enhancement of Heat Transfer and Energy Recovery)
  • Article
  • Open Access
13 Citations
3,553 Views
28 Pages

Response to the COVID-19 Pandemic in Classrooms at the University of the Basque Country through a User-Informed Natural Ventilation Demonstrator

  • Iñigo Rodríguez-Vidal,
  • Alexander Martín-Garín,
  • Francisco González-Quintial,
  • José Miguel Rico-Martínez and ,
  • Rufino J. Hernández-Minguillón and
  • Jorge Otaegi
  • + 1 author+ 0 author

The COVID-19 pandemic has generated a renewed interest in indoor air quality to limit viral spread. In the case of educational spaces, due to the high concentration of people and the fact that most of the existing buildings do not have any mechanical...

of 17