Skip to Content

82 Results Found

  • Article
  • Open Access
1 Citations
980 Views
25 Pages

Active–Passive Responsibility-Driven Overvoltage Mitigation for Sustainable Distribution Networks with High Distributed Photovoltaic Penetration

  • Ting Yang,
  • Qi Cheng,
  • Shengkui Bai,
  • Dongwei Wu and ,
  • Butian Chen,
  • Danhong Lu and
  • Han Wu
  • + 2 authors+ 0 author

8 May 2026

Distributed photovoltaic (PV) systems play an important role in supporting low-carbon and sustainable distribution network development; however, their high-penetration integration can cause nodal overvoltage, as midday PV generation often exceeds loc...

(This article belongs to the Section Energy Sustainability)
  • Article
  • Open Access
25 Citations
4,761 Views
20 Pages

A Coordinated Voltage Control for Overvoltage Mitigation in LV Distribution Grids

  • Edoardo De Din,
  • Marco Pau,
  • Ferdinanda Ponci and
  • Antonello Monti

17 April 2020

The design of intelligent strategies for grid management is a cost-effective solution to increase the hosting capacity of distribution grids without investing in the reinforcement of the grid assets. This paper presents a distributed voltage control...

(This article belongs to the Special Issue Monitoring and Control of Active Electrical Distribution Grids and Urban Energy Grids)
  • Article
  • Open Access
16 Citations
4,446 Views
18 Pages

27 August 2020

The Ferranti effect could cause a rise in voltage along the cables on a wind farm if the circuit breakers at the receiving ends are switched off. Ferroresonance could also occur due to stuck pole(s) of the circuit breaker during de-energization. This...

(This article belongs to the Section A3: Wind, Wave and Tidal Energy)
  • Article
  • Open Access
25 Citations
4,362 Views
14 Pages

Performance Evaluation of Solar PV Inverter Controls for Overvoltage Mitigation in MV Distribution Networks

  • Dilini Almeida,
  • Jagadeesh Pasupuleti,
  • Shangari K. Raveendran and
  • M. Reyasudin Basir Khan

The incorporation of real and reactive power control of solar photovoltaic (PV) inverters has received significant interest as an onsite countermeasure to the voltage rise problem. This paper presents a comprehensive analysis of the involvement of ac...

(This article belongs to the Section Power Electronics)
  • Article
  • Open Access
4 Citations
1,440 Views
20 Pages

28 November 2025

In recent years, the rapid increase in installed photovoltaic (PV) capacity in Poland has created significant challenges for low-voltage distribution networks. Excess generation during peak solar hours frequently leads to local overvoltage conditions...

  • Article
  • Open Access
1 Citations
1,163 Views
20 Pages

25 December 2025

To address the challenges of system failures and equipment damage caused by excitation inrush currents and overvoltages during no-load energization of high-speed locomotive transformers, a simulation model was developed utilizing PSCAD electromagneti...

  • Article
  • Open Access
26 Citations
5,379 Views
26 Pages

Battery Storage Integration in Voltage Unbalance and Overvoltage Mitigation Control Strategies and Its Impact on the Power Quality

  • Dimitar Bozalakov,
  • Mohannad J. Mnati,
  • Joannes Laveyne,
  • Jan Desmet and
  • Lieven Vandevelde

20 April 2019

The increased utilisation of distributed renewable energy sources in low voltage grids leads to power quality problems such as overvoltages and voltage unbalance. This imposes challenges to the distribution system operators to maintain the power qual...

  • Article
  • Open Access
19 Citations
6,555 Views
16 Pages

12 December 2016

This paper presents a comprehensive investigation on high frequency (HF) switching transients due to energization of vacuum circuit breakers (VCBs) in offshore wind farms (OWFs). This research not only concerns the modeling of main components in coll...

  • Article
  • Open Access
8 Citations
3,737 Views
12 Pages

28 March 2019

The pantograph arcing phenomenon may shorten the service life of a pantograph and even destroy onboard devices and instruments, due to the irregular motions of the train and the intermittent line–pantograph disconnection. This paper points out...

(This article belongs to the Section B: Energy and Environment)
  • Feature Paper
  • Article
  • Open Access
818 Views
24 Pages

Wide-bandgap transistors have short voltage rise and fall times, thus leading to overvoltage at the end of the cable connecting the inverter and the motor. In this paper, the overvoltage reduction possibilities have been investigated analytically, ex...

(This article belongs to the Special Issue Advanced Technologies in Power Electronics)
  • Feature Paper
  • Article
  • Open Access
726 Views
26 Pages

8 April 2026

This work uses battery-coupled power electronic converter systems and distributed backstepping controllers to improve the reliability of electrical distribution networks. The motivation is to prevent blackouts such as the 28 April 2025 outage in Spai...

(This article belongs to the Special Issue Reliability of Power Electronics Devices and Converter Systems: 2nd Edition)
  • Article
  • Open Access
3 Citations
5,927 Views
34 Pages

24 August 2020

Direct lightning strikes on overhead phase conductors result in high overvoltage stress on the medium voltage (MV) terminals of pole-mounted transformers, which may cause considerable damage. Therefore, introducing an efficient protection strategy wo...

(This article belongs to the Special Issue Simulation and Analysis of High Voltage Engineering in Power Systems)
  • Article
  • Open Access
6 Citations
3,385 Views
13 Pages

A Distribution Static Synchronous Compensator Application to Mitigate Voltage Variation for Distribution Feeders

  • Te-Tien Ku,
  • Chia-Hung Lin,
  • Chao-Shun Chen,
  • Yih-Der Lee and ,
  • Jheng-Lun Jiang,
  • Sing-Jia Tzeng and
  • Chen-Min Chan
  • + 2 authors+ 0 author

27 July 2023

With the growing penetration of distributed energy resources (DER), the accompanying challenges have led utilities to limit the hosting capacities of DER installations on distribution feeders. A distribution static synchronous compensator (DSTATCOM)...

(This article belongs to the Special Issue Advanced Research on Smart Grid, Energy Storage and Distribution Systems)
  • Article
  • Open Access
5 Citations
2,817 Views
15 Pages

Research on Lightning Overvoltage Protection of Line-Adjacent Pipelines Based on Solid-State Decoupling

  • Wei Liu,
  • Yuanchao Hu,
  • Haipeng Tian,
  • Zhipeng Jiang and ,
  • Xiaole Su,
  • Jie Xiong,
  • Wei Su and
  • Yi Wang
  • + 3 authors+ 0 author

20 November 2023

Existing transmission lines and pipelines are frequently crossed and erected in parallel, meaning that if lightning strikes a wire and causes insulator flashovers, the resulting lightning current will spread through the grounding of the tower where t...

(This article belongs to the Special Issue Grounding Systems Optimization for Low-Frequency Fault Currents and Lightning Strikes)
  • Article
  • Open Access
4 Citations
5,225 Views
17 Pages

18 March 2021

This paper focuses on the investigation and implementation of a high-performance power conversion system to reduce the overvoltage phenomenon in variable speed electric drive applications. Particularly, the pros and cons of using Silicon Carbide powe...

(This article belongs to the Special Issue High-Efficiency and High-Performance Power Electronics for Power Grids and Electrical Drives)
  • Article
  • Open Access
5 Citations
2,551 Views
14 Pages

21 November 2023

Ferroresonance, as an undesirable disturbance, leads to significant overvoltage and distorted waveforms. This phenomenon can be highly damaging to voltage transformers and other parallel-connected equipment and can entail catastrophic consequences. T...

(This article belongs to the Section F: Electrical Engineering)
  • Article
  • Open Access
5 Citations
3,165 Views
28 Pages

Voltage Regulation For Residential Prosumers Using a Set of Scalable Power Storage

  • Igor Cavalcante Torres,
  • Daniel M. Farias,
  • Andre L. L. Aquino and
  • Chigueru Tiba

4 June 2021

Among the electrical problems observed from the solar irradiation variability, the electrical energy quality and the energetic dispatch guarantee stand out. The great revolution in batteries technologies has fostered its usage with the installation o...

  • Article
  • Open Access
6 Citations
3,423 Views
18 Pages

9 November 2022

Problems with overvoltage and reverse energy flow arise as the percentage of distribution energy resources (DERs) in distribution system rises. This paper implements a MATLAB/Simulink linked model that communicates with the OpenDSS engine. The point...

(This article belongs to the Special Issue Smart Energy Control & Conversion Systems)
  • Article
  • Open Access
52 Citations
11,991 Views
16 Pages

The greater integration of solar photovoltaic (PV) systems into low-voltage (LV) distribution networks has posed new challenges for the operation of power systems. The violation of voltage limits attributed to reverse power flow has been recognized a...

(This article belongs to the Section Power Electronics)
  • Article
  • Open Access
3 Citations
2,627 Views
28 Pages

A Smart Grid Overvoltage Identification System Associated with Partial Discharge Signal and Dielectric Loss Detection

  • Guojin Chen,
  • Yucheng Zhu,
  • Zihao Meng,
  • Weixing Fang and ,
  • Wei Xie,
  • Ming Xu and
  • Wenxin Li
  • + 2 authors+ 0 author

7 September 2023

Capacitive equipment refers to its insulation design using the principle of capacitance of electrical equipment, mainly by a variety of different capacitive components in series. Most of the equipment in the substation is capacitive equipment. Once a...

(This article belongs to the Section Industrial Sensors)
  • Article
  • Open Access
583 Views
15 Pages

Sine-Wave Filter Design Method for High-Speed PMSMs in High-Frequency (250 Hz) Drives

  • Genmao Zhou,
  • Yinquan Ding,
  • Zhennan Du,
  • Yiwei Tang and ,
  • Li Chen,
  • Guohui Yang and
  • Gang Zhang
  • + 2 authors+ 0 author

In industrial applications such as in situ leaching and uranium mining, permanent magnet synchronous motors (PMSMs) for submersible pumps are frequently connected to frequency converters via long cables. During this long-distance transmission, travel...

  • Article
  • Open Access
2 Citations
3,815 Views
17 Pages

13 May 2024

Single-phase input rectifier brushless DC motor drives with a small film capacitor have many advantages, such as high power density and high reliability. However, when the motor system operates in regenerative braking mode, the dc-link capacitor with...

(This article belongs to the Special Issue Power Electronics and Actuators)
  • Article
  • Open Access
3 Citations
2,781 Views
32 Pages

2 August 2023

In this paper, variable reactance (VR) criteria are proposed to mitigate voltage deviations in power transformers under light-load inductive and capacitive conditions, as well as for over-load conditions. Under capacitive load conditions, power trans...

(This article belongs to the Section Electromechanical Energy Conversion Systems)
  • Article
  • Open Access
8 Citations
2,426 Views
16 Pages

Optimal Synchronous Condenser Placement in Renewable Energy Bases to Meet Renewable Energy Transfer Capacity Requirements

  • Hao Sheng,
  • Siqi Zhang,
  • Tianqi Zhao,
  • Jing Hao and ,
  • Qi Li,
  • Guangming Xin,
  • Rui Chen,
  • Xiaofei Wang and
  • Xiang Ren
  • + 4 authors+ 0 author

11 August 2025

The large-scale integration of renewable energy and the high penetration of power electronic devices have led to a significant reduction in system inertia and short-circuit capacity. This is particularly manifested in the form of insufficient multipl...

(This article belongs to the Special Issue Analysis and Control of Power System Stability)
  • Article
  • Open Access
21 Citations
5,647 Views
16 Pages

6 August 2018

Expansion of photovoltaic (PV) generation is increasing the challenge for network operators to keep voltages within operational limits. Voltage rise occurs in low voltage (LV) networks when distributed generators export, particularly at times of low...

  • Article
  • Open Access
3 Citations
1,258 Views
26 Pages

14 November 2025

As renewable energy sources increasingly penetrate power systems, ensuring operational stability during grid faults poses a significant challenge. Conventional fault-ride-through (FRT) control strategies often lack systematic parameter optimization,...

(This article belongs to the Topic Power System Dynamics and Stability, 2nd Edition)
  • Article
  • Open Access
17 Citations
4,171 Views
18 Pages

Sequentially Coordinated and Cooperative Volt/Var Control of PV Inverters in Distribution Networks

  • Fathy Aboshady,
  • Oguzhan Ceylan,
  • Ahmed F. Zobaa,
  • Aydogan Ozdemir and ,
  • Gareth Taylor and
  • Ioana Pisica
  • + 1 author+ 0 author

Electric distribution grids are seeing an increased penetration of photovoltaic (PV) generation. High PV generation exceeding the grid load demand results in a reverse active power flow in the grid, which raises the voltage level. This paper presents...

(This article belongs to the Special Issue Advances in Electrical Power Engineering—Selected Papers from 57th International Universities Power Engineering Conference (UPEC2022))
  • Article
  • Open Access
1 Citations
1,849 Views
18 Pages

Research on Opening Reignition Characteristics and Suppression Measures of 750 kV AC Filter Circuit Breakers

  • Jianguo Zhang,
  • Pengcheng Sha,
  • Feiyue Ma,
  • Bo Niu and ,
  • Xu Cai,
  • Hui Ni and
  • Junbo Deng
  • + 2 authors+ 0 author

6 January 2025

The operation of converter valves in converter stations often results in high reactive power consumption and harmonic generation, necessitating measures to maintain reactive power balance and ensure power quality. To achieve this, the filter bank cir...

(This article belongs to the Section F6: High Voltage)
  • Article
  • Open Access
567 Views
20 Pages

Power Shifting Strategy Based on Extended Operation Region for VSC-MTDC System Integrated with Offshore Wind Farms

  • Qian Wu,
  • Yuchao Zheng,
  • Linyuan Wang,
  • Meng Ruan and ,
  • Zhiyun Zheng,
  • Zhichao Yang and
  • Bingtuan Gao
  • + 2 authors+ 0 author

Multi-terminal voltage source converter-based high voltage direct current (VSC-MTDC) technology has become an efficient solution for grid integration of large-scale and long-distance offshore wind power. When onshore grid power fluctuations elevate t...

(This article belongs to the Special Issue Cutting-Edge Technologies in Offshore Wind Energy)
  • Article
  • Open Access
6 Citations
2,941 Views
19 Pages

The Impact of the Shunt Reactor(s) Location on Offshore Wind Farm Power Export System on Zero-Missing Phenomenon and Switching Overvoltages—The Case of a Polish Power System

  • Piotr Rzepka,
  • Mateusz Szablicki,
  • Marcin Niedopytalski,
  • Adrian Halinka and ,
  • Daria Zychma and
  • Michał Szewczyk
  • + 1 author+ 0 author

27 November 2024

The observed development of offshore wind farms has resulted in an increasing presence of long extra-high voltage cables, with lengths ranging from 10 to 200 km. These cable lines are compensated for by a shunt reactor(s). The transient states that a...

(This article belongs to the Special Issue Energy, Electrical and Power Engineering: 3rd Edition)
  • Article
  • Open Access
77 Views
29 Pages

18 November 2026

Medium-voltage overhead distribution networks are exposed to atmospheric overvoltages and environmental pollution that can compromise external insulation performance. This paper proposes an integrated methodology for insulation coordination, surge-ar...

(This article belongs to the Section Electrical and Electronic Engineering)
  • Article
  • Open Access
13 Citations
4,619 Views
14 Pages

5 December 2022

This paper presents a stochastic approach to assessing the hosting capacity for solar PV. The method is part of the optimal techniques for the integration of renewables. There are two types of uncertainties, namely aleatory and epistemic uncertaintie...

  • Article
  • Open Access
12 Citations
3,282 Views
17 Pages

6 May 2024

As offline control photovoltaic (PV) plants are not equipped with online communication and remote control systems, they cannot adjust their power in real-time. Therefore, in a distribution network saturated with offline control PVs, the distribution...

(This article belongs to the Special Issue Optimal Planning and Operation in RES-Rich Power Systems under Electricity and Carbon Emission Market Environment)
  • Article
  • Open Access

Coordinated Fault Ride-Through Control for a Hierarchically Connected VSC-HVDC System

  • Wei Wei,
  • Peng Zhang,
  • Zhiyong Zhang,
  • Lilong Zhou and ,
  • Pen Gu and
  • Jianyu Zhou
  • + 1 author+ 0 author

23 November 2026

As voltage-source converter-based high-voltage direct-current (VSC-HVDC) transmission systems evolve toward higher power ratings and voltage levels, a hierarchical configuration in which series-connected receiving-end converter units are connected to...

  • Review
  • Open Access
34 Citations
7,783 Views
30 Pages

Impact of PWM Voltage Waveforms in High-Speed Drives: A Survey on High-Frequency Motor Models and Partial Discharge Phenomenon

  • Davide D’Amato,
  • Jelena Loncarski,
  • Vito Giuseppe Monopoli,
  • Francesco Cupertino and ,
  • Luigi Pio Di Noia and
  • Andrea Del Pizzo
  • + 1 author+ 0 author

15 February 2022

The insulation system’s dielectric of the electric motor is very often subjected to severe electrical stress generated by the high dv/dt seen at the machine’s terminals. The electrical stress and high reflected wave transient overvoltage...

(This article belongs to the Special Issue Power Electronic Circuits for Electric Drives and Renewable Energy Sources)
  • Article
  • Open Access
1 Citations
1,542 Views
23 Pages

Analysis and Control of Voltage Stability in Offshore Wind Systems Under Small Disturbances

  • João P. L. Dantas,
  • Marley F. Tavares,
  • Ana J. O. Marques and
  • Murilo E. C. Bento

9 June 2025

This paper proposes an analysis of voltage stability under small disturbances following the integration of an offshore wind farm into a real power system, considering various load and generation scenarios under both normal and post-disturbance condit...

(This article belongs to the Section F1: Electrical Power System)
  • Article
  • Open Access
15 Citations
3,329 Views
24 Pages

This article investigates the impacts of coordinated false data injection attacks (FDIAs) on voltage profiles in smart microgrids integrated with renewable-based distributed energy resources (DERs), a critical component of urban energy infrastructure...

  • Article
  • Open Access
6 Citations
3,129 Views
27 Pages

Hybrid Control of Grid-Feeding and Fuzzy Logic Fault Detection in Solving Voltage Dynamic Problem within the Malaysian Distribution Network

  • Ong Kam Hoe,
  • Agileswari K. Ramasamy,
  • Lee Jun Yin,
  • Renuga Verayiah and ,
  • Marayati Binti Marsadek and
  • Muhammad Abdillah
  • + 1 author+ 0 author

15 June 2021

The stochastic behavior of PV together with high PV penetration have given rise to power quality concerns involving voltage dynamic issues such as undervoltage, overvoltage, sag and swell. To ensure the grid’s stability, various methods have been pra...

  • Article
  • Open Access
420 Views
14 Pages

7 September 2026

With an increase in the High-Voltage Direct Current (HVDC) infeed, the strength of the receiving-end AC grid decreases, leading to transient voltage instability. Voltage source converter (VSC)-HVDC stations have a large unit capacity and high control...

(This article belongs to the Section F1: Electrical Power System)
  • Feature Paper
  • Article
  • Open Access
20 Citations
4,145 Views
21 Pages

29 March 2024

Recently, there has been a significant increase in the integration of distributed energy resources (DERs) such as small-scale photovoltaic systems and wind turbines in power distribution systems. When the aggregated outputs of DERs are combined, exce...

(This article belongs to the Special Issue Advances in Research and Practice of Smart Electric Power Systems)
  • Article
  • Open Access
1 Citations
1,307 Views
25 Pages

Best Practice in PCB Design with Experimental Validation of a 50 A-120 V Converter for Low-Voltage Propulsion and Energy Applications

  • Matteo Villa,
  • Simone Cosso,
  • Alessandro Benevieri,
  • Luis Vaccaro and ,
  • Massimiliano Passalacqua,
  • Simon Kissling,
  • Mauro Carpita and
  • Mario Marchesoni
  • + 3 authors+ 0 author

27 October 2025

Low-voltage power converters in the 25–200 V range are increasingly employed in emerging applications such as hybrid electric vehicles (HEVs), photovoltaic systems with battery storage, and electric propulsion systems for recreational boats. In...

(This article belongs to the Topic Energy Management and Efficiency in Electric Motors, Drives, Power Converters and Related Systems, 2nd Edition)
  • Feature Paper
  • Article
  • Open Access
1,550 Views
18 Pages

18 September 2025

The integration of photovoltaic (PV) systems into power grids has surged due to the global shift towards renewable energy, but this rapid adoption presents challenges like voltage regulation and inverter degradation. High PV penetration can lead to o...

(This article belongs to the Special Issue Recent Advances in Renewable Energy Systems: Integration Challenges, Forecasting, and Grid Optimization for Sustainable Energy Management)
  • Article
  • Open Access
8 Citations
1,886 Views
24 Pages

Strategies to Mitigate Reverse Power Flow in Distribution Networks with High Penetration of Solar Photovoltaic Generation

  • Ivan Santos Pereira,
  • Gustavo da Costa Vergara,
  • Jesús M. López-Lezama,
  • Nicolás Muñoz-Galenao and
  • Lina Paola Garcés Negrete

19 February 2026

The power industry has undergone significant recent changes due to the growing demand for a cleaner and more sustainable energy mix. In this context, the Brazilian government began encouraging distributed generation (DG), making photovoltaic generati...

  • Feature Paper
  • Article
  • Open Access
1,417 Views
16 Pages

Prioritizing BESS Selection to Improve System Contingency Responses: Results of a Case Study Conducted Using the SRP Power System

  • Venkata Nagarjuna Anudeep Kandrathi,
  • Dhaval Dalal,
  • Anamitra Pal,
  • Philip Augustin and
  • Matthew Rhodes

17 September 2025

Battery energy storage systems (BESSs) have become integral components of grid modernization because of their ability to provide system stabilization in the presence of high levels of renewable generation. Specifically, the dynamic response capabilit...

(This article belongs to the Section F1: Electrical Power System)
  • Article
  • Open Access
51 Citations
7,395 Views
16 Pages

18 April 2021

In this study, we mitigated the harmonic voltage in a power system that contained the roughing mill (RM) and finishing mill (FM) motor drives. AC/DC converter type RM drive is a non-linear, large-capacity varying load that adversely affects power qua...

(This article belongs to the Special Issue Analysis and Experiment for Electric Power Quality)
  • Article
  • Open Access
22 Citations
2,901 Views
17 Pages

Modified Cascaded Controller Design Constructed on Fractional Operator ‘β’ to Mitigate Frequency Fluctuations for Sustainable Operation of Power Systems

  • Muhammad Majid Gulzar,
  • Sadia Murawwat,
  • Daud Sibtain,
  • Kamal Shahid and ,
  • Imran Javed and
  • Yonghao Gui
  • + 1 author+ 0 author

21 October 2022

The demand for energy is increasing at an abrupt pace, which has highly strained the power system, especially with high share of power generation from renewable energy sources (RES). This increasing strain needs to be effectively managed for a contin...

(This article belongs to the Special Issue Control of Renewable Energy Sources in Power Systems and Smart Grids)
  • Article
  • Open Access
8 Citations
3,966 Views
20 Pages

30 June 2021

In general, a temporary overvoltage (TOV) on the healthy phases occurs because of the neutral-shift phenomenon during a single line-to-ground (SLG) fault. The TOV can destroy the insulation of electric devices and cause damage to other equipment and...

  • Article
  • Open Access
12 Citations
5,515 Views
18 Pages

Design of Damping Strategies for LC Filter Applied in Medium Voltage Variable Speed Drive

  • Diuary Gonçalves,
  • João Victor Matos Farias,
  • Heverton Augusto Pereira,
  • Alex-Sander Amável Luiz and ,
  • Marcelo Martins Stopa and
  • Allan Fagner Cupertino
  • + 1 author+ 0 author

4 August 2022

In recent years, medium-voltage variable-speed drives have become popular in the industry. However, in some applications, the use of long cables can lead to overvoltages at the motor terminals, affecting the motor lifespan. Under such conditions, the...

(This article belongs to the Special Issue Advances in Power Electronic Converters with Application in Renewable Energy Sources)
  • Article
  • Open Access
5 Citations
1,582 Views
22 Pages

Maskable PPO-Based Topology Control for Reverse Power Flow Mitigation in PV-Rich Distribution Networks

  • Tu Lan,
  • Ruisheng Diao,
  • Wangjie Xu,
  • Jiehua Ju and ,
  • Xuanchen Xiang and
  • Kunqi Jia
  • + 1 author+ 0 author

19 November 2025

The rapid proliferation of photovoltaic (PV) generation has transformed conventional distribution systems, resulting in frequent reverse power flow (RPF) and associated overvoltage issues. This paper presents a deep reinforcement learning (DRL)-based...

(This article belongs to the Special Issue AI-Driven Solutions for Operation and Control of Future Smart Grids)
  • Article
  • Open Access
10 Citations
1,464 Views
18 Pages

Transient Overvoltage Prediction Method for Renewable Energy Stations via Knowledge-Embedded Enhanced Deep Neural Network

  • Guangyao Wang,
  • Jun Liu,
  • Jiacheng Liu,
  • Yuting Li and ,
  • Tianxiao Mo and
  • Sheng Ju
  • + 1 author+ 0 author

24 February 2025

When a line-commutated converter–high-voltage direct current (LCC-HVDC) transmission system with large-scale integration of renewable energy encounters HVDC-blocking events, the sending-end power system is prone to transient overvoltage (TOV) r...

(This article belongs to the Section F1: Electrical Power System)

of 2