A Robust Vector Current Controller with Negative-Sequence Current Capability for Grid-Connected Inverters

  • Houshang Karimi,
  • Aboutaleb Haddadi,
  • Masoud Karimi-Ghartemani and
  • Mahdieh Sadabadi

27 July 2021

This paper presents a vector current controller (in the synchronous reference, or the dq, frame) with negative-sequence current injection capability for three-phase grid-connected converters. This capability is desired for the operation of the conver...

(This article belongs to the Topic Power System Modeling and Control)
  • Article
  • Open Access
325 Views
22 Pages

Fractional-Order Composite Control for Fractional-Order Modular Multilevel Converters

  • Yongzeng Xie,
  • Fei Lan,
  • Junhua Xu,
  • Yingheng Li and
  • Fulin Luo

The existing basic control system of fractional-order modular multilevel converters (FO-MMCs) is mainly designed for ideal operating conditions and exhibits limited adaptability under grid unbalanced conditions. To address this issue, this paper prop...

(This article belongs to the Topic Modeling, Stability, and Control of Dynamic Systems and Their Applications)
  • Article
  • Open Access
234 Views
20 Pages

28 September 2026

Asymmetric grid voltage sags induce double-frequency power oscillations and three-phase current imbalance in virtual synchronous generators (VSGs). Though conventional multi-objective optimization via active negative-sequence current injection can ac...

  • Article
  • Open Access
3 Citations
2,000 Views
15 Pages

9 November 2023

The negative-sequence current component and harmonic components generated when an asymmetrical fault occurs in the power grid seriously affect the normal operation of the photovoltaic (PV) grid-connected inverter. In order to suppress the negative-se...

(This article belongs to the Section A2: Solar Energy and Photovoltaic Systems)
  • Article
  • Open Access
30 Citations
4,885 Views
22 Pages

16 October 2018

This paper reports a new control strategy to improve sharing of unbalanced currents in islanded LV microgrids. This technique provides fast and effective sharing of positive-, negative- and zero-sequence currents, and is the first example of zero-seq...

(This article belongs to the Special Issue Operation and Control of Power Distribution Systems)
  • Article
  • Open Access
2 Citations
932 Views
16 Pages

Small-Signal Stability of Large-Scale Integrated Hydro–Wind–Photovoltaic Storage (HWPS) Systems Based on the Linear Time-Periodic (LTP) Method

  • Ruikuo Liu,
  • Hong Xiao,
  • Zefei Wu,
  • Jingshu Shi and ,
  • Bin Wang,
  • Hongqiang Xiao,
  • Depeng Hu,
  • Ziqi Jia,
  • Guojie Zhao and
  • Yingbiao Li
  • + 5 authors+ 0 author

31 October 2025

In recent years, renewable energy generation (RPG) has experienced rapid growth, and large-scale hydro–wind–photovoltaic storage (HWPS) bases have been progressively developed in southwest China, where hydropower resources are abundant. E...

(This article belongs to the Special Issue Operation and Control of New Power System with Large-Scale Renewable Energy Integration)
  • Article
  • Open Access
2 Citations
1,269 Views
15 Pages

14 June 2025

With the increasing integration of Inverter-Based Resources (IBRs) into power grids, accurate estimation of line impedance between the Point of Connection (POC) and the Point of Measurement (POM) has become critical to ensure stable and efficient rea...

(This article belongs to the Special Issue Renewable and Sustainable Energy in Light of Energy Transition Processes—2nd Edition)
  • Article
  • Open Access
2 Citations
1,329 Views
24 Pages

Research on Directional Elements of Two-Terminal Weak-Feed AC Systems with a Negative Sequence Control Strategy

  • Yan Li,
  • Wentao Yang,
  • Xiaofang Wu,
  • Runbin Cao and ,
  • Weihuang Huang,
  • Faxi Peng and
  • Junjie Hou
  • + 2 authors+ 0 author

25 November 2024

It has become a typical scenario in power systems that renewable energy power supply is connected to an AC system through flexible DC transmission. However, since both sides of the AC line are power electronic converters, the negative sequence suppre...

(This article belongs to the Special Issue Advanced Online Monitoring and Fault Diagnosis of Power Equipment)
  • Article
  • Open Access
1 Citations
2,135 Views
13 Pages

30 November 2023

With the increased grid-connected capacity of a single-phase distributed power supply, three-phase power unbalance is more likely to occur in a power grid. Three-phase power unbalance can further lead to three-phase voltage unbalance, which can have...

(This article belongs to the Special Issue Advances and Challenges in Power Systems with High Penetration of Renewable Energies)
  • Article
  • Open Access
1 Citations
1,214 Views
19 Pages

7 May 2025

This paper presents an enhanced bipolar control strategy for 400 Hz three-phase inverters in aviation ground power supplies, with a focus on maintaining symmetry in power output under unbalanced load conditions. The strategy integrates Linear Active...

(This article belongs to the Special Issue Applications of Symmetry Three-Phase Electrical Power Systems)
  • Article
  • Open Access
4 Citations
1,635 Views
17 Pages

14 May 2025

The present study investigates the control strategy of a novel doubled-fed induction generator (DFIG) with a series grid-side converter (SGSC) during grid faults. The rotor-side inverter is subject to a control strategy derived from the Model Predict...

(This article belongs to the Special Issue Control and Optimization of Power Converters)
  • Article
  • Open Access
15 Citations
5,412 Views
19 Pages

Influence of Negative Sequence Injection Strategies on Faulted Phase Selector Performance

  • María Teresa Villén,
  • Maria Paz Comech,
  • Eduardo Martinez Carrasco and
  • Aníbal Antonio Prada Hurtado

19 August 2022

Renewable power is expected to increase drastically in the coming years due to the energy transition. A large part of the newly installed generators will be connected to the power system through inverters and electronic converters, whose behaviour di...

(This article belongs to the Section F: Electrical Engineering)
  • Article
  • Open Access
6 Citations
3,984 Views
18 Pages

15 June 2022

The growing penetration of renewable resources such as wind and solar into the electric power grid through power electronic inverters is challenging grid protection. Due to the advanced inverter control algorithms, the inverter-based resources presen...

(This article belongs to the Collection Renewable Energy and Energy Storage Systems)
  • Article
  • Open Access
16 Citations
4,530 Views
16 Pages

Reactive Power Compensation and Imbalance Suppression by Star-Connected Buck-Type D-CAP

  • Xiaosheng Wang,
  • Ke Dai,
  • Xinwen Chen,
  • Xin Zhang and ,
  • Qi Wu and
  • Ziwei Dai
  • + 1 author+ 0 author

18 May 2019

Reactive power and negative-sequence current generated by inductive unbalanced load will not only increase line loss, but also cause the malfunction of relay protection devices triggered by a negative-sequence component in the power grid, which threa...

(This article belongs to the Special Issue HVDC/FACTS for Grid Services in Electric Power Systems)
  • Article
  • Open Access
766 Views
17 Pages

Collaborative Suppression Strategy for AC Asymmetric Faults in Offshore Wind Power MMC-HVDC Systems

  • Xiang Lu,
  • Chenglin Ren,
  • Shi Jiao,
  • Jie Shi and ,
  • Weicheng Li and
  • Hailin Li
  • + 1 author+ 0 author

12 January 2026

When offshore wind power is connected to a grid via Modular multilevel converter-based High Voltage Direct Current (MMC-HVDC), the sending-end alternating current (AC) system is susceptible to asymmetrical faults. These faults lead to overcurrent sur...

(This article belongs to the Special Issue Advances in Diagnostic Analysis, Strategic Management, and Proactive Maintenance of Electrical Equipment—2nd Edition)
  • Article
  • Open Access
12 Citations
2,905 Views
19 Pages

Transient Synchronous Stability Analysis of Grid-Forming Photovoltaic Grid-Connected Inverters during Asymmetrical Grid Faults

  • Wenwen He,
  • Jun Yao,
  • Hao Xu,
  • Qinmin Zhong and ,
  • Ruilin Xu,
  • Yuming Liu and
  • Xiaoju Li
  • + 2 authors+ 0 author

14 March 2024

Compared with the traditional grid-following photovoltaic grid-connected converter (GFL-PGC), the grid-forming photovoltaic grid-connected converter (GFM-PGC) can provide voltage and frequency support for power systems, which can effectively enhance...

(This article belongs to the Special Issue Grid-Forming Technologies for Renewable Energy Integration)
  • Article
  • Open Access
18 Citations
5,254 Views
27 Pages

The Applicability of Traditional Protection Methods to Lines Emanating from VSC-HVDC Interconnectors and a Novel Protection Principle

  • Shimin Xue,
  • Jingyue Yang,
  • Yanxia Chen,
  • Cunping Wang and ,
  • Zhe Shi,
  • Miao Cui and
  • Botong Li
  • + 2 authors+ 0 author

25 May 2016

Voltage source converter (VSC)-based high voltage direct current (VSC-HVDC) interconnectors can realize accurate and fast control of power transmission among AC networks, and provide emergency power support for AC networks. VSC-HVDC interconnectors b...

  • Article
  • Open Access
16 Citations
4,050 Views
17 Pages

26 June 2018

Voltage source converters (VSCs) are able to provide both positive- and negative-sequence short circuit currents under unbalanced faults. Their short circuit responses can be significantly different from those of conventional synchronous generators....

(This article belongs to the Section F: Electrical Engineering)
  • Article
  • Open Access
285 Views
19 Pages

Influence of Harmonic and DC-Bias Coupling on Transformer Energization Inrush Current in Complex Power Grids

  • Junchi He,
  • Chenlei Li,
  • Shaofan Gu,
  • Shoujiang He and ,
  • Shouhua Pan,
  • Wenjing Xu,
  • Fei Ren,
  • Fan Xu,
  • Jintao Yu and
  • Xiaozhen Zhao
  • + 6 authors+ 1 author

20 September 2026

The methodological innovation of this study is a phase-domain separation-and-recombination framework that maps harmonic voltage to prospective flux, maps controlled quasi-DC winding current to magnetic operating-point displacement, and then resolves...

(This article belongs to the Special Issue Advances in Diagnostic Analysis, Strategic Management, and Proactive Maintenance of Electrical Equipment—2nd Edition)
  • Article
  • Open Access
100 Views
30 Pages

5 November 2026

Synchronized fixed-frequency current control (SFFC) enables inverter-dominated islanded microgrids to regulate power without relying on frequency deviations. However, conventional SFFC may exhibit power oscillations when battery storage systems (BSSs...

(This article belongs to the Special Issue Power Electronics, Motor Drives, and Grid Stability in Renewable Energy Systems)
  • Study Protocol
  • Open Access
2 Citations
1,204 Views
13 Pages

27 May 2025

As an innovative solution, the virtual synchronous generator (VSG) facilitates the seamless incorporation of renewable energy into power grids. It also exhibits the ability to reconfigure system inertia and deliver damping effects, thereby assuming a...

  • Proceeding Paper
  • Open Access
849 Views
11 Pages

1 September 2026

Grid-following inverters play a vital role in integrating renewable energy systems into modern power grids. However, their performance deteriorates under grid voltage unbalance and uncertain grid impedance, resulting in current distortion and double-...

(This article belongs to the Proceedings of The 1st International Online Conference on Inventions)
  • Article
  • Open Access
1,079 Views
19 Pages

Decoupling Control for the HVAC Port of Power Electronic Transformer

  • Wusong Wen,
  • Tianwen Zhan,
  • Yingchao Zhang and
  • Jintong Nie

4 August 2025

For the high-voltage AC port of power electronic transformer (HVAC-PET) with three-phase independent DC buses on the low-voltage side, a decoupling control strategy, concerning the influence of grid voltage imbalance, three-phase active-load imbalanc...

  • Article
  • Open Access
298 Views
18 Pages

A Droop-Based PI-QPR Control Strategy for Islanded Parallel-Inverter Microgrids

  • Jinhao Shen,
  • Hua Zhang,
  • Xueneng Su,
  • Yiwen Gao and ,
  • Kun Zheng,
  • Cheng Long and
  • Xinbo Liu
  • + 2 authors+ 0 author

11 August 2026

Parallel-inverter microgrids are prone to PCC voltage distortion during islanded operation with nonlinear and unbalanced loads. Virtual-impedance methods can reshape inverter output impedance, but they also add control complexity and may introduce ex...

  • Article
  • Open Access
2 Citations
1,687 Views
22 Pages

The Unbalanced Control Research of Fractional-Order Cascaded H-Bridge Multilevel STATCOM

  • Junhua Xu,
  • Guopeng He,
  • Songqin Tang,
  • Zheng Gong and ,
  • Chunwei Wang and
  • Yue Lan
  • + 1 author+ 0 author

Recent research on fractional-order cascaded H-bridge multilevel static compensator (FCHM-STATCOM) indicates that it has better performance than the traditional cascaded H-bridge multilevel static compensator (CHM-STATCOM). The existing FCHM-STATCOM...

(This article belongs to the Special Issue Fractional-Order Circuits, Systems, and Signal Processing, 2nd Edition)
  • Article
  • Open Access
16 Citations
6,255 Views
25 Pages

Hybrid LQR-PI Control for Microgrids under Unbalanced Linear and Nonlinear Loads

  • Gerardo Humberto Valencia-Rivera,
  • Luis Ramon Merchan-Villalba,
  • Guillermo Tapia-Tinoco,
  • Jose Merced Lozano-Garcia and ,
  • Mario Alberto Ibarra-Manzano and
  • Juan Gabriel Avina-Cervantes
  • + 1 author+ 0 author

4 July 2020

A hybrid Linear Quadratic Regulator (LQR) and Proportional-Integral (PI) control for a MicroGrid (MG) under unbalanced linear and nonlinear loads was presented and evaluated in this paper. The designed control strategy incorporates the microgrid beha...

(This article belongs to the Special Issue Advanced Modeling and Research in Hybrid Microgrid Control and Optimization)
  • Article
  • Open Access
3 Citations
2,803 Views
20 Pages

High Frequency Resonance Suppression Strategy of Three-Phase Four-Wire Split Capacitor Inverter Connected to Parallel Compensation Grid

  • Guoli Feng,
  • Zhihao Ye,
  • Yihui Xia,
  • Heng Nian and ,
  • Liming Huang and
  • Zerun Wang
  • + 1 author+ 0 author

17 February 2022

With the continuous penetration and development of renewable energy power generation, the distributed grid and the microgrid are becoming increasingly important in modern power systems. In distribution networks and the microgrid, the grid impedance i...

(This article belongs to the Topic Optimisation, Optimal Control and Nonlinear Dynamics in Electrical Power, Energy Storage and Renewable Energy Systems)
  • Article
  • Open Access
1 Citations
816 Views
25 Pages

The project of the flexible direct transmission of renewable energy has become an inevitable development trend for the large-scale grid connection of renewable energy. Its two-terminal weakly fed AC system is often composed of 100% power electronic e...

(This article belongs to the Special Issue Advanced Online Monitoring and Fault Diagnosis of Power Equipment)
  • Article
  • Open Access
6 Citations
7,883 Views
15 Pages

8 August 2011

Operation of doubly fed induction generators subjected to transient unbalanced voltage dips is analyzed in this article to verify the fulfillment of the Spanish grid code. Akagi’s p-q theory is not used for this study, because control of the electron...

  • Article
  • Open Access
3 Citations
2,042 Views
12 Pages

Intratumoral Microbiome in Head and Neck Paragangliomas

  • Maria Fedorova,
  • Anastasiya Snezhkina,
  • Dmitry Kalinin,
  • Elena Pudova and ,
  • Margarita Lantsova,
  • George Krasnov,
  • Vladislav Pavlov and
  • Anna Kudryavtseva
  • + 3 authors+ 0 author

23 August 2024

Head and neck paragangliomas (HNPGLs) are rare neoplasms arising from paraganglia of the parasympathetic nervous system. HNPGLs are characterized by high vascularity and are located in proximity to major vessels and nerves, which may be potential sou...

(This article belongs to the Special Issue Rare Diseases and Neuroscience)
  • Article
  • Open Access
30 Citations
3,101 Views
14 Pages

Coordinated LVRT Support for a PMSG-Based Wind Energy Conversion System Integrated into a Weak AC-Grid

  • Akrama Khan,
  • Hasnain Ahmad,
  • Syed Muhammad Ahsan,
  • Muhammad Majid Gulzar and
  • Sadia Murawwat

13 October 2021

In a grid, the choice of the point of common coupling (PCC) does not solely rely on the voltage level alone but also conjointly depends on the grid strength for many explicit purposes. Nowadays, the affinity of low SCR grid connections has become a c...

(This article belongs to the Section A3: Wind, Wave and Tidal Energy)
  • Article
  • Open Access
661 Views
19 Pages

13 February 2026

To address the low-voltage fault issue in doubly fed induction generator-motor (DFIGM) systems, this paper proposes a practically implementable cooperative control strategy that integrates an improved current reversely tracking control (CRTC) scheme...

(This article belongs to the Special Issue Reliability Metrology, Testing and Failure Analysis of Semiconductor Devices)
  • Article
  • Open Access
10 Citations
3,462 Views
18 Pages

Power Control and Fault Ride-Through Capability Analysis of Cascaded Star-Connected SVG under Asymmetrical Voltage Conditions

  • Muxuan Xiao,
  • Feng Wang,
  • Zhixing He,
  • Honglin Ouyang and ,
  • Renyifan Hao and
  • Qianming Xu
  • + 1 author+ 0 author

19 June 2019

The cascaded H-bridge static var generator (SVG) has been employed to provide reactive power and regulate grid voltages for many years because of its good modularity, easy scalability, and improved harmonic performance. A novel cluster-balancing powe...

(This article belongs to the Section F: Electrical Engineering)
  • Article
  • Open Access
26 Citations
5,359 Views
26 Pages

Battery Storage Integration in Voltage Unbalance and Overvoltage Mitigation Control Strategies and Its Impact on the Power Quality

  • Dimitar Bozalakov,
  • Mohannad J. Mnati,
  • Joannes Laveyne,
  • Jan Desmet and
  • Lieven Vandevelde

20 April 2019

The increased utilisation of distributed renewable energy sources in low voltage grids leads to power quality problems such as overvoltages and voltage unbalance. This imposes challenges to the distribution system operators to maintain the power qual...

  • Article
  • Open Access
37 Citations
9,786 Views
17 Pages

Control Strategy for a Grid-Connected Inverter under Unbalanced Network Conditions—A Disturbance Observer-Based Decoupled Current Approach

  • Emre Ozsoy,
  • Sanjeevikumar Padmanaban,
  • Lucian Mihet-Popa,
  • Viliam Fedák and ,
  • Fiaz Ahmad,
  • Rasool Akhtar and
  • Asif Sabanovic
  • + 2 authors+ 0 author

22 July 2017

This paper proposes a new approach on the novel current control strategy for grid-tied voltage-source inverters (VSIs) with circumstances of asymmetrical voltage conditions. A standard grid-connected inverter (GCI) allows the degree of freedom to int...

(This article belongs to the Special Issue Energy Storage Systems and Power Conversion Electronics for E-Transportation and Smart Grid)
  • Article
  • Open Access
183 Views
22 Pages

30 October 2026

Large-scale photovoltaic (PV) plants connected to weak grids may experience oscillations caused by interactions between converter controls and grid impedance. This paper develops a linear time-periodic (LTP) small-signal model by linearizing nonlinea...

(This article belongs to the Special Issue Power-Electronics-Based New-Type Power Systems: Data Analysis, Planning, Operation, and Stability Control)
  • Article
  • Open Access
589 Views
15 Pages

The DC Voltage Balance Strategy Based on Model Predictive Control with a Smooth Switching Sequence in Three-Phase 3LNPC-CR

  • Xu Peng,
  • Hang Li,
  • Lu Liu,
  • Xiaohan Liu and ,
  • Siqi An and
  • Weidong Peng
  • + 1 author+ 0 author

12 February 2026

The three-level neutral-point-clamped cascaded rectifier (3LNPC-CR) is a key component in power electronic transformers (PET) due to its high efficiency and modular configuration. However, voltage imbalance among submodule DC links may cause system i...

(This article belongs to the Special Issue Research Progress and Prospects of Multi-Level Converters)
  • Article
  • Open Access
7 Citations
2,773 Views
12 Pages

11 May 2021

Three-phase imbalance is a long-term issue existing in low-voltage distribution networks (LVDNs), which consequently has an inverse impact on the safe and optimal operation of LVDNs. Recently, the increasing integration of single-phase distributed ge...

(This article belongs to the Section F: Electrical Engineering)
  • Article
  • Open Access
5 Citations
3,684 Views
16 Pages

A Novel Single-Terminal Fault Location Method for AC Transmission Lines in a MMC-HVDC-Based AC/DC Hybrid System

  • Shimin Xue,
  • Junchi Lu,
  • Chong Liu,
  • Yabing Sun and ,
  • Baibing Liu and
  • Cheng Gu
  • + 1 author+ 0 author

8 August 2018

Accurate and reliable fault location method for alternating current (AC) transmission lines is essential to the fault recovery. MMC-based converter brings exclusive non-linear characteristics to AC networks under single-phase-to-ground faults, thus i...

(This article belongs to the Special Issue Fault Diagnosis on MV and HV Transmission Lines)
  • Article
  • Open Access
1 Citations
384 Views
29 Pages

LCL-type grid-connected inverters face problems including complex modeling, sampled current distortion from harmonics and negative-sequence components, and reduced control accuracy of conventional deadbeat predictive current control (DPCC) due to its...

(This article belongs to the Section Power Electronics)
  • Article
  • Open Access
15 Citations
8,038 Views
16 Pages

Analysis of Stationary- and Synchronous-Reference Frames for Three-Phase Three-Wire Grid-Connected Converter AC Current Regulators

  • Israel D. L. Costa,
  • Danilo I. Brandao,
  • Lourenço Matakas Junior,
  • Marcelo G. Simões and
  • Lenin M. F. Morais

10 December 2021

The current state of the art shows that unbalance and distortion on the voltage waveforms at the terminals of a grid-connected inverter disturb its output currents. This paper compares AC linear current regulators for three-phase three-wire voltage s...

(This article belongs to the Topic Power System Modeling and Control)
  • Article
  • Open Access
34 Citations
5,815 Views
21 Pages

13 December 2019

Whereas power-electronics-based power systems are expected to enable more integration of renewable energy sources, they could pose crucial challenges including stability issues due to the Thévenin impedance seen by inverters. Such problems cou...

(This article belongs to the Special Issue Integration of PV in Distribution Networks)
  • Article
  • Open Access
17 Citations
5,995 Views
20 Pages

14 May 2020

To ensure system stability, national grid codes often require converter-based generators to provide fault-ride-through (FRT) capabilities and dynamic voltage support, according to which they should stay connected and support the voltage during fault...

(This article belongs to the Special Issue Control Strategies for Power Conversion Systems)
  • Article
  • Open Access
16 Citations
6,726 Views
28 Pages

27 July 2019

This article deals with the vector control in dq axes of a three-phase grid-connected photovoltaic system with single-stage topology and low-voltage-ride-through capability. The photovoltaic generator is built using an array of several series-paralle...

  • Article
  • Open Access
9 Citations
4,360 Views
23 Pages

2 August 2020

The asymmetric faults often cause the power grid current imbalance and power grid oscillation, which brings great instability risk to the power grid. To address this problem, this paper presented a modeling and parameter optimization method of grid-c...

(This article belongs to the Special Issue Electric Power Systems Research 2020)
  • Article
  • Open Access
345 Views
27 Pages

Conventional integer-order parameter designs of grid-forming inverters provide limited degrees of freedom for impedance adjustment, motivating the exploration of additional approaches for flexible impedance reshaping across different frequency ranges...

(This article belongs to the Topic Modeling, Stability, and Control of Dynamic Systems and Their Applications, 2nd Edition)
  • Article
  • Open Access
4 Citations
3,407 Views
18 Pages

14 May 2024

The electrical protection of power networks with fault contribution from inverter-based power sources imposes new application challenges that have to be dealt with by protection engineers. This paper describes the development of a study case model of...

(This article belongs to the Section Fault Diagnosis & Sensors)
  • Article
  • Open Access
2 Citations
1,624 Views
18 Pages

26 August 2024

Under the condition of grid voltage imbalance, the circulation of the bridge arm inside the modular multilevel converter (MMC) increases significantly, which leads to the aggravation of the distortion of the bridge arm current, and, thus, increases t...

(This article belongs to the Special Issue Advanced Control in Power Electronics, Drives and Generators)
  • Article
  • Open Access
2 Citations
1,796 Views
23 Pages

Research on Energy Storage-Based DSTATCOM for Integrated Power Quality Enhancement and Active Voltage Support

  • Peng Wang,
  • Jianxin Bi,
  • Fuchun Li,
  • Chunfeng Liu and ,
  • Yuanhui Sun,
  • Wenhuan Cheng,
  • Yilong Wang and
  • Wei Kang
  • + 3 authors+ 0 author

With the increasing penetration of distributed generation and the diversification of electrical equipment, distribution networks face issues like three-phase unbalance and harmonic currents, while the voltage stability and inertia of the grid-connect...

  • Article
  • Open Access
1 Citations
2,089 Views
16 Pages

31 May 2023

The high penetration of inverter-based distributed generations (IBDGs) leads to traditional distribution networks’ complex and variable fault characteristics. Traditional passive detection protection methods can hardly meet the stability and re...

of 27