Skip to Content

228 Results Found

  • Article
  • Open Access
1 Citations
717 Views
23 Pages

23 March 2026

This paper investigates a five-level active neutral-point-clamped (5L-ANPC) converter operating in rectifier mode with unbalanced DC-side loads, where neutral-point (NP) deviation may deteriorate grid-current quality. Conventional space-vector pulsew...

(This article belongs to the Section F3: Power Electronics)
  • Article
  • Open Access
4 Citations
2,040 Views
14 Pages

22 September 2022

The DC-link capacitors in an electronic power system are the main constraint of the power density and lifespan of the power converters. Evaluating the load life of capacitors working in severely adverse circumstances plays an important role in the de...

(This article belongs to the Special Issue Power Quality in Smart Grids: Advanced Technology for System Regulation and Analysis)
  • Article
  • Open Access
11 Citations
3,088 Views
19 Pages

An improved density-based spatial clustering of applications with noise (IDBSCAN) analysis approach based on kurtosis and sample entropy (SE) is presented for the identification of operational state in order to provide accurate monitoring of spindle...

(This article belongs to the Special Issue Rolling Bearing and Rotor System Modeling and Simulation, Monitoring and Control, and Performance Diagnosis)
  • Article
  • Open Access
3 Citations
3,694 Views
11 Pages

20 September 2021

Since a T-type three-level PWM converter has several advantages in terms of harmonics and conduction loss, it has been widely adopted for various low voltage applications. However, a neutral point voltage control is necessarily required for stable sy...

  • Feature Paper
  • Article
  • Open Access
3 Citations
1,978 Views
29 Pages

10 March 2024

This study proposes an unbalanced current compensation method based on a four-leg inverter using an artificial neural network (ANN) under unbalanced load conditions. Distribution systems exhibit rapid load variations, and conventional filter-based co...

(This article belongs to the Special Issue Advanced Control, Optimization, Stability and Reliability of Microgrids and Power Systems)
  • Article
  • Open Access
16 Citations
4,979 Views
18 Pages

16 February 2021

Leg capacitor energy balancing control is one of the crucial issues for stable operation of a cascaded H-bridge (CHB) converter. Because this topology inherently consists of numerous submodule cells with DC capacitors, the cell voltages and leg capac...

  • Article
  • Open Access
13 Citations
6,276 Views
24 Pages

Lyapunov Stability and Performance Analysis of the Fractional Order Sliding Mode Control for a Parallel Connected UPS System under Unbalanced and Nonlinear Load Conditions

  • Muhammad Ali,
  • Muhammad Aamir,
  • Hussain Sarwar Khan,
  • Asad Waqar and ,
  • Faheem Haroon and
  • Atif Raza Jafri
  • + 1 author+ 0 author

13 December 2018

Parallel-connected uninterruptible power supply (UPS) systems have been used to maintain power supply to the critical load in order to increase power capacity and system reliability. This paper presents a robust and precise voltage control strategy f...

(This article belongs to the Section F: Electrical Engineering)
  • Article
  • Open Access
9 Citations
2,301 Views
24 Pages

23 August 2024

Multi-functional photovoltaic (PV) inverters incorporate ancillary services to enhance power quality and mitigate stability issues in distribution networks. These next-generation PV inverters will achieve a higher utilization of the inverter’s...

(This article belongs to the Section A2: Solar Energy and Photovoltaic Systems)
  • Article
  • Open Access
20 Citations
4,252 Views
23 Pages

Early Identification of Unbalanced Freight Traffic Loads Based on Wayside Monitoring and Artificial Intelligence

  • R. Silva,
  • A. Guedes,
  • D. Ribeiro,
  • C. Vale and ,
  • A. Meixedo,
  • A. Mosleh and
  • P. Montenegro
  • + 2 authors+ 0 author

31 January 2023

The identification of instability problems in freight trains circulation such as unbalanced loads is of particular importance for railways management companies and operators. The early detection of unbalanced loads prevents significant damages that m...

(This article belongs to the Section Fault Diagnosis & Sensors)
  • Article
  • Open Access
8 Citations
4,893 Views
27 Pages

17 August 2018

This paper presents a non-iterative technique that generates reference current to manage operation of a three-phase four-wire shunt active power filter which employs a three-leg split capacitor voltage source inverter (VSI) topology. The proposed tec...

  • Article
  • Open Access
8 Citations
5,684 Views
21 Pages

4 June 2018

Conventional short-circuit studies often neglect the load current because the short-circuit current (SCC) flowing from generators is much greater than the SCC that is affected by various loading conditions. As distributed or clustered loads that are...

  • Proceeding Paper
  • Open Access
7 Citations
15,718 Views
12 Pages

20 September 2023

Electrical Power quality in distribution systems is crucial to both utility and consumers simultaneously. The main issue that affects the quality factor of electrical distribution systems is phase load imbalance. Phase imbalance is a major issue in d...

(This article belongs to the Proceedings of The 8th International Electrical Engineering Conference)
  • Article
  • Open Access
2 Citations
1,840 Views
30 Pages

Modern power systems present opportunities and challenges when integrating distributed generation and electric vehicle charging stations into unbalanced distribution networks. The performance and efficiency of both Distributed Generation (DG) and Ele...

(This article belongs to the Special Issue Power and Energy Systems for E-mobility)
  • Article
  • Open Access
32 Citations
4,418 Views
22 Pages

Optimization of Voltage Unbalance Compensation by Smart Inverter

  • Ryuto Shigenobu,
  • Akito Nakadomari,
  • Ying-Yi Hong,
  • Paras Mandal and ,
  • Hiroshi Takahashi and
  • Tomonobu Senjyu
  • + 1 author+ 0 author

5 September 2020

This paper presents a compensation method for unbalanced voltage through active and reactive power control by utilizing a smart inverter that improves the voltage unbalance index and detects an unbalanced state of voltage magnitude and phase, and thu...

(This article belongs to the Section A1: Smart Grids and Microgrids)
  • Article
  • Open Access
5 Citations
4,256 Views
11 Pages

9 February 2021

This paper varies load conditions in a single-phase induction motor and deals with consequent effects on the electromagnetic characteristics in terms of a balanced and unbalanced operation. Based on a balanced-load condition, the magnetic field, elec...

(This article belongs to the Special Issue Advances in Motor and Drive)
  • Article
  • Open Access
24 Citations
6,927 Views
21 Pages

1 December 2017

A three-phase four-leg inverter-based shunt active power filter (APF) is proposed to compensate three-phase unbalanced currents under unbalanced load conditions in grid-connected operation in this study. Since a DC-link capacitor is required on the D...

(This article belongs to the Special Issue Emerging Power Electronics Technologies for Power Systems and Machine Drives)
  • Article
  • Open Access
20 Citations
5,296 Views
17 Pages

26 September 2022

Proposed in this article is bidirectional real and reactive power control of a three-phase grid-connected inverter under unbalanced grid conditions using a proportional-resonance controller. Different unbalanced grid conditions have been studied, suc...

(This article belongs to the Section F3: Power Electronics)
  • Article
  • Open Access
16 Citations
2,490 Views
27 Pages

Exploiting the Moth–Flame Optimization Algorithm for Optimal Load Management of the University Campus: A Viable Approach in the Academia Sector

  • Ibrar Ullah,
  • Irshad Hussain,
  • Khalid Rehman,
  • Piotr Wróblewski and ,
  • Wojciech Lewicki and
  • Balasubramanian Prabhu Kavin
  • + 1 author+ 0 author

19 May 2022

Unbalanced load condition is one of the major issues of all commercial, industrial and residential sectors. Unbalanced load means that, when different loads are distributed on a three-phase four-wire system, unequal currents pass through the three ph...

(This article belongs to the Special Issue Thermo-Mechanical and Electrical Measurements for Energy Systems)
  • Proceeding Paper
  • Open Access
3 Citations
2,026 Views
6 Pages

15 September 2022

The distinction of inter-turn short-circuit faults (ITSCF) from abnormal conditions, such as an unbalanced voltage supply condition, has been challenging over the last few years. The asymmetries caused by both conditions are similar, therefore the de...

(This article belongs to the Proceedings of The 1st International Electronic Conference on Machines and Applications)
  • Article
  • Open Access
4 Citations
3,193 Views
23 Pages

16 December 2022

Discussed in this study is a bidirectional power control technique for a three-phase grid connected inverter under different unbalanced grid conditions. Prior researchers have focused on either solving the unbalanced problem or controlling the power....

(This article belongs to the Section F3: Power Electronics)
  • Article
  • Open Access
642 Views
17 Pages

Modified Negative-Sequence Overcurrent Protection for Operation Under Load Asymmetry Conditions

  • Denis Fedosov,
  • Iliya Iliev,
  • Hristo Beloev,
  • Konstantin Suslov and ,
  • Anton Suslov,
  • Ilia Shuspanov and
  • Ivan Beloev
  • + 2 authors+ 0 author

This article examines the performance of negative-sequence overcurrent protection during short circuits in the presence of current asymmetry caused by single-phase loads, such as those encountered in AC railway traction systems. The impact of unbalan...

  • Article
  • Open Access
4 Citations
3,358 Views
20 Pages

Power Converter Resonant Control for an Unbalanced and Non-Constant Frequency Supply

  • Jaime Rohten,
  • Felipe Villarroel,
  • José Silva,
  • Esteban Pulido and ,
  • Fabián Pierart,
  • Johan Guzmán and
  • Luis García-Santander
  • + 2 authors+ 0 author

19 May 2023

Distorted voltage supplied as unbalanced and/or non-constant frequency can be found in weak grids, such as microgrids, or systems working in islanding mode. These kinds of systems are more sensitive under load changes. Particularly, an unbalanced vol...

(This article belongs to the Section Intelligent Sensors)
  • Article
  • Open Access
1 Citations
473 Views
24 Pages

A Control Method for Three-Phase Inverters Based on Adaptive Parameters of Fractional-Order QPCIs

  • Mingyuan Hu,
  • Bo Gao,
  • Ying-Ren Chien,
  • Lei Zhang and ,
  • Qimeng Sun,
  • Yang Liu and
  • Jingwen Liu
  • + 2 authors+ 0 author

In order to improve the performance of three-phase NPC inverters under unbalanced working conditions, a quasi-proportional complex integral controller (QPCI) three-phase inverter control method based on an adaptive fractional-order algorithm is propo...

(This article belongs to the Special Issue Fractional-Order Controllers in Electronics and Automation Engineering, 2nd Edition)
  • Article
  • Open Access
4 Citations
2,318 Views
24 Pages

This paper discusses the operation and control of a low-voltage DC (LVDC) isolated distribution network powered by distributed generation (DG) from a variable-speed wind turbine induction generator (WTIG) to supply unbalanced AC loads. The system inc...

  • Article
  • Open Access
18 Citations
5,114 Views
18 Pages

27 March 2018

Wind turbine generating systems (WTGSs), which are conventionally connected to high voltage transmission networks, have frequently been employed as distributed generation units in today’s distribution networks. In practice, the distribution networks...

  • Article
  • Open Access
8 Citations
5,556 Views
16 Pages

22 September 2022

Presented in this paper is a method of bidirectional real and reactive power control of a three-phase grid-connected inverter under unbalanced grid situations. Unbalanced three-phase load and unbalanced grid impedance are illustrations of unbalanced...

(This article belongs to the Special Issue Control and Modeling of Power Converters and Inverters)
  • Article
  • Open Access
1,484 Views
25 Pages

Voltage Balancing of a Bipolar DC Microgrid with Unbalanced Unipolar Loads and Sources

  • Mateus Pinheiro Dias,
  • Debora P. Damasceno,
  • Eliabe Duarte Queiroz,
  • Kristian P. dos Santos and ,
  • Jose C. U. Penã and
  • José A. Pomilio
  • + 1 author+ 0 author

19 November 2025

This paper presents the validation of a voltage balancing converter for a bipolar DC microgrid designed to ensure reliable operation in both grid-connected and islanded modes. This microgrid includes unipolar constant power loads (CPL), a unipolar Ba...

(This article belongs to the Special Issue Advances in Power Converters in Energy and Microgrid Systems)
  • Article
  • Open Access
166 Views
26 Pages

13 November 2026

Multilevel (ML) neutral-point-clamped (NPC) dual-active-bridge (DAB) topologies have emerged as a promising solution for multiport dc-dc power conversion systems. In particular, the 4L NPC DAB is a promising solution for the auxiliary power module (A...

(This article belongs to the Special Issue Power Converters for Modern Power Systems: Analysis, Modeling, and Control)
  • Article
  • Open Access
18 Citations
5,708 Views
17 Pages

4 February 2017

Three-phase unbalance is an important power quality issue that can cause many negative effects to the power system. Effective mitigation and management of voltage unbalance will benefit from the knowledge of how the unbalanced sources contribute to t...

(This article belongs to the Special Issue Electric Power Systems Research 2017)
  • Article
  • Open Access
3 Citations
2,643 Views
25 Pages

Disturbance Observer-Based Feedback Linearized Controller for Grid-Forming Four-Leg VSI Supplying Unbalanced and Nonlinear Loads

  • Samantha S. Stephen,
  • Hussain Shareef,
  • Rachid Errouissi,
  • Mahdiyeh Eslami and
  • Tuanku Badzlin Hashfi

6 July 2024

This paper presents the design of a disturbance observer-based controller that regulates the output voltage of three-phase four-leg voltage source inverters (VSIs) deployed for grid-forming operation in Renewable Energy-based Distributed Generation (...

(This article belongs to the Section F: Electrical Engineering)
  • Article
  • Open Access
9 Citations
3,080 Views
21 Pages

13 April 2022

A study on the capacity increase of a power converter according to the increase in the single capacity of wave energy converters and four-leg topology that can supply stable power even under unbalanced load conditions during independent operation is...

(This article belongs to the Special Issue Marine Renewable Energy Technology)
  • Article
  • Open Access
2 Citations
2,888 Views
13 Pages

5 May 2022

In general, severe load imbalances in small AC micro-grid systems can degrade their operational performance and their maintenance. This is because the unbalanced load in the micro-grid affects the energy flow and the voltage regulation functions of e...

(This article belongs to the Special Issue Review of Advanced Power Electronics Solutions)
  • Article
  • Open Access
2 Citations
743 Views
20 Pages

AC-Voltage Support and Speed Control Strategy for DFIG-Based Gravity Energy Storage Systems Under Unbalanced Grid

  • Yan Li,
  • Darui He,
  • Jiao Dai,
  • Jiaqi Zheng and ,
  • Fangyuan Tian,
  • Yuanshi Zhang and
  • Chenwen Cheng
  • + 2 authors+ 0 author

16 November 2025

This paper presents an optimized control strategy based on a Doubly Fed Induction Generator (DFIG) and Gravity Energy Storage System (GESS) for AC voltage support in unbalanced grid conditions. The presented control aims to achieve precise rotational...

(This article belongs to the Special Issue Intelligent Control Strategies for Power Electronics)
  • Article
  • Open Access
20 Citations
3,842 Views
26 Pages

Improved Voltage Unbalance and Harmonics Compensation Control Strategy for an Isolated Microgrid

  • Mohammad Jafar Hadidian Moghaddam,
  • Akhtar Kalam,
  • Mohammad Reza Miveh,
  • Amirreza Naderipour and ,
  • Foad H. Gandoman,
  • Ali Asghar Ghadimi and
  • Zulkurnain Abdul-Malek
  • + 2 authors+ 0 author

9 October 2018

This paper suggests an enhanced control scheme for a four-leg battery energy storage systems (BESS) under unbalanced and nonlinear load conditions operating in the isolated microgrid. Simplicity, tiny steady-state error, fast transient response, and...

  • Article
  • Open Access
13 Citations
8,996 Views
16 Pages

13 September 2012

When a three-phase induction generator (IG) supplies unbalanced loads, its terminal voltages and line currents are also unbalanced, which may cause the IG to overheat and need to be derated. A single-phase loaded self-excited induction generator (SEI...

(This article belongs to the Special Issue Electrical Power and Energy Systems)
  • Article
  • Open Access
1 Citations
1,275 Views
22 Pages

2 August 2025

As a core device in low-voltage distribution networks, the distribution zone transformer (DZT) is influenced by short circuits, overloads, and unbalanced loads, which cause thermal aging, mechanical stress, and eventually deformation of the winding,...

  • Article
  • Open Access
34 Citations
2,010 Views
19 Pages

Investigations on the Modulation Strategies for Performance Improvement of a Controlled Wind Energy System

  • Rajababu Durgam,
  • Ramsha Karampuri,
  • Shriram S. Rangarajan,
  • Umashankar Subramaniam and ,
  • E. Randolph Collins and
  • Tomonobu Senjyu
  • + 1 author+ 0 author

28 November 2022

The challenges faced in an isolated wind energy conversion system (WECS) are larger transient times, high steady-state error, and larger harmonic content. To overcome these issues, an adaptive voltage controller (AVC) along with the load current obse...

(This article belongs to the Section Industrial Electronics)
  • Article
  • Open Access
162 Views
35 Pages

5 November 2026

This paper presents a theoretical and numerical extension of Budeanu’s power theory for three-phase three-wire systems supplied by symmetrical nonsinusoidal voltages and feeding unbalanced linear time-invariant loads. The proposed formulation c...

  • Article
  • Open Access
3 Citations
3,264 Views
21 Pages

29 October 2021

Three-phase unbalanced and nonlinear loads aggravate harmonic problems in low-voltage distribution networks. In this paper, a hybrid inductive and active filter (HIAF) system with a Ddy converter transformer is proposed. By establishing the circuit a...

(This article belongs to the Special Issue Design and Control of Electrical Machines)
  • Article
  • Open Access
14 Citations
4,909 Views
16 Pages

An Experimental Study on a Wind Turbine Rotor Affected by Pitch Imbalance

  • Francesco Mazzeo,
  • Derek Micheletto,
  • Alessandro Talamelli and
  • Antonio Segalini

18 November 2022

An experimental and numerical investigation about the pitch imbalance effect on a wind turbine model is performed. The characterization of the power losses and loads generated on a small-scale model and the validation of an analytical framework for t...

(This article belongs to the Section A3: Wind, Wave and Tidal Energy)
  • Article
  • Open Access
441 Views
37 Pages

Fully Native DPL-Based Conductor Sizing Optimization for Distribution Networks in DIgSILENT PowerFactory

  • Víctor Mario Vélez-Marín,
  • Oscar Danilo Montoya and
  • Jesús C. Hernández

This paper presents a fully native optimization framework, implemented within DIgSILENT PowerFactory, which is aimed at solving the optimal conductor sizing problem (OCSP) in electrical distribution systems under realistic operating conditions. Our m...

(This article belongs to the Special Issue Innovative Power System Technologies—Second Edition)
  • Article
  • Open Access
12 Citations
4,801 Views
28 Pages

17 November 2022

Superconducting magnetic energy storage (SMES) systems are characterized by their high-power density; they are integrated into high-energy density storage systems, such as batteries, to produce hybrid energy storage systems (HESSs), resulting in the...

  • Article
  • Open Access
6 Citations
3,333 Views
13 Pages

15 July 2023

This paper addresses the diagnostics of stator faults in three-phase line-start permanent magnet synchronous motors. More traditional fault diagnostic methodologies are unable to properly diagnose stator inter-turn short-circuit faults in three-phase...

(This article belongs to the Section Electrical Machines and Drives)
  • Article
  • Open Access
3 Citations
6,010 Views
13 Pages

12 June 2017

This paper discusses harmonic current compensation of the constant DC-capacitor voltage-control (CDCVC)-based strategy of smart chargers for electric vehicles (EVs) in single-phase three-wire distribution feeders (SPTWDFs) under nonlinear load condit...

(This article belongs to the Special Issue Power Electronics in Power Quality)
  • Article
  • Open Access
2 Citations
2,774 Views
18 Pages

23 August 2022

The underground energy geostructure represented by the energy pile is one of the key paths for the cooperative development of underground space and geothermal energy. Because of its advantages of low cost, high efficiency and no extra occupation of u...

(This article belongs to the Special Issue Fracture and Failure of Jointed Rock Mass)
  • Article
  • Open Access
2 Citations
3,009 Views
21 Pages

Advection-Based Coordinated Control for Wave-Energy Converter Array

  • Hong Li,
  • Bo Zhang,
  • Li Qiu,
  • Shiyu Chen and ,
  • Jianping Yuan and
  • Jianjun Luo
  • + 1 author+ 0 author

18 September 2019

This paper presents a coordinated control based on the advection consensus control algorithm to implement power dispatch for each wave-energy converter (WEC) in a WEC array. Under unbalanced conditions, the proposed algorithm is applied in order to c...

(This article belongs to the Special Issue Wave Energy Conversion)
  • Article
  • Open Access
14 Citations
4,950 Views
16 Pages

11 March 2019

The influence of the heights of low-level jets (LLJs) on the rotor power and aerodynamic loads of a horizontal axis wind turbine were investigated using the fatigue, aerodynamics, structures, and turbulence code. The LLJ and shear inflow wind fields...

  • Article
  • Open Access
2 Citations
1,365 Views
27 Pages

6 May 2026

Self-excited induction generators (SEIGs) used in wind energy systems suffer from poor voltage and frequency regulation due to varying active/reactive power demands of nonlinear and unbalanced loads. The distribution static compensator (DSTATCOM) pro...

(This article belongs to the Section Fault Diagnosis & Sensors)
  • Article
  • Open Access
1 Citations
620 Views
38 Pages

Measurement-Driven Phase-Resolved Modeling of Unbalanced Nonlinear Loads for Harmonic Assessment and Mitigation in Building Distribution Systems

  • Nestor F. Guerrero-Rodríguez,
  • Rafael Omar Batista-Jorge,
  • Vrindarani Nuñez-Ramírez,
  • Abraham Manilla-García and ,
  • Francisco A. Ramírez-Rivera,
  • Robert Mercado-Ravelo,
  • Julio A. Ferreira and
  • Juan G. Faxas-Guzmán
  • + 3 authors+ 0 author

20 June 2026

Nonlinear loads in modern buildings are often represented using balanced or frequency-domain approximations that do not fully capture phase asymmetry and time-domain distortion observed under field operating conditions. This study aims to develop and...

(This article belongs to the Section F: Electrical Engineering)
  • Article
  • Open Access
71 Citations
12,158 Views
20 Pages

20 October 2017

Two mismatch functions (power or current) and three coordinates (polar, Cartesian and complex form) result in six versions of the Newton–Raphson method for the solution of power flow problems. In this paper, five new versions of the Newton power flow...

(This article belongs to the Special Issue Selected Papers from International Workshop of Energy-Open)