Skip to Content

1,892 Results Found

  • Review
  • Open Access
38 Citations
10,406 Views
30 Pages

Latest Advances in Finite Element Modelling and Model Updating of Cable-Stayed Bridges

  • Thomas Sharry,
  • Hong Guan,
  • Andy Nguyen,
  • Erwin Oh and
  • Nam Hoang

As important links in the transport infrastructure system, cable-stayed bridges are among the most popular candidates for implementing structural health monitoring (SHM) technology. The primary aim of SHM for these bridges is to ensure their structur...

(This article belongs to the Special Issue Structural Health Monitoring of Civil Infrastructures)
  • Article
  • Open Access
546 Views
15 Pages

28 September 2026

This study develops a reduced IEC 60287-based thermal model and an IEC-informed neural-network approximation for ampacity prediction in a 132 kV directly buried aluminium cable reference system. The analytical implementation is calibrated at a single...

  • Article
  • Open Access
678 Views
26 Pages

Hamiltonian Modelling and Hierarchical Sliding-Mode Control of a Cable-Driven Soft Exoskeleton for Lower-Limb Rehabilitation Assistance

  • Fernando Abel Navarro-Martínez,
  • Esther Lugo-González,
  • Juan Javier Montesinos-García,
  • Jorge Luis Barahona-Avalos and
  • Hugo Fermín Ramírez-Leyva

2 September 2026

Soft exoskeletons have attracted increasing attention as wearable robotic devices for lower limb rehabilitation and assistive mobility. This study presents an integrated modelling, control, and mechanical design framework for a cable-driven soft exos...

(This article belongs to the Special Issue Applications of Emerging Biomedical Devices and Systems)
  • Article
  • Open Access
13 Citations
3,582 Views
17 Pages

14 February 2022

Cable failure is an extremely critical situation in the operation of cable-driven parallel robots (CDPR), as the robot might be instantly outside of its predefined workspace. Therefore, the calculation of a cable force distribution might fail and, th...

(This article belongs to the Special Issue Dynamics and Control of Robot Manipulators)
  • Article
  • Open Access
173 Views
17 Pages

Dynamic Modeling and Cable Tension Optimization of a Redundantly Constrained Cable-Driven Parallel Robot

  • Tao Zhao,
  • Hengfa Wu,
  • Xin Dong,
  • Xiaojun Ding and ,
  • Yang Gao and
  • Sen Qian
  • + 1 author+ 0 author

3 November 2026

To address the problems of cable slackness and non-smooth cable-tension variation curves during the motion of an antagonistic cable-driven parallel robot (CDPR), this paper focuses on a three-degree-of-freedom (DOF) redundantly constrained CDPR. Firs...

(This article belongs to the Special Issue Parallel Kinematic Machines: Actuation, Design, and Applications)
  • Article
  • Open Access
4 Citations
4,063 Views
20 Pages

Efficient Finite Element Modeling of Steel Cables in Reinforced Rubber

  • Martin Pletz,
  • Siegfried Martin Frankl and
  • Clara Schuecker

Spiral steel cables feature complex deformation behavior due to their wound geometry. In applications where the cables are used to reinforce rubber components, modeling the cables is not trivial, because the cable’s outer surface must be connec...

(This article belongs to the Special Issue Characterization and Modelling of Composites, Volume II)
  • Article
  • Open Access
447 Views
24 Pages

21 September 2026

This study investigates model-based emergency strategies for damage prevention following cable breaks in six-degree-of-freedom cable-driven parallel robots. By relaxing real-time constraints, the empirical performance limit of existing and novel reco...

(This article belongs to the Section Intelligent Robots and Mechatronics)
  • Article
  • Open Access
2 Citations
1,220 Views
19 Pages

Characteristic Impedance Modeling of Nuclear Power Instrumentation and Control Cable Shield Breakage

  • Hua Tu,
  • Chao Peng,
  • Yanyi Chen,
  • Lixing Li and ,
  • Honglei Deng and
  • Gang Liu
  • + 1 author+ 0 author

6 June 2025

Nuclear Instrumentation and Control (I&C) cables laying in a complex environment are prone to shield damage. And, the traveling wave reflection method can be used to detect and locate damage using the characteristic impedance change caused by I&a...

  • Article
  • Open Access
9 Citations
3,722 Views
16 Pages

30 September 2022

This paper proposes and validates using experimental data a dynamic model to determine the current–temperature relationship of insulated and jacketed cables in air. The model includes the conductor core, the inner insulation layer, the outer in...

  • Article
  • Open Access
13 Citations
5,638 Views
17 Pages

27 December 2021

Cable-driven parallel robots (CDPRs) have several advantages and have been widely used in many industrial fields, especially industrial applications that require high dynamics, high payload capacity, and a large workspace. In this study, a design mod...

(This article belongs to the Special Issue Selected Papers from iTIKI IEEE ICASI 2021)
  • Article
  • Open Access
13 Citations
2,447 Views
21 Pages

23 April 2024

Cross-sea cable-stayed bridges encounter challenges associated with cable corrosion and cable-force relaxation during their service life, which significantly affects their structural performance and seismic response. This study focuses on a cross-sea...

(This article belongs to the Topic New Trends in Advanced Construction Technology, Sustainable Construction Materials and High-Performance Building Structures)
  • Article
  • Open Access
2 Citations
2,112 Views
26 Pages

4 November 2024

Accurate temperature prediction of the operating tunnel cable is crucial for its safe and efficient function. To achieve a rapid and accurate prediction of the steady-state temperature of the tunnel cable, the self-modeling pattern in natural convect...

(This article belongs to the Section F6: High Voltage)
  • Article
  • Open Access
18 Citations
6,612 Views
19 Pages

7 August 2017

The calculation of frequency-dependent cable parameters is essential for simulations of transient phenomena in electrical power systems. The simulation of transients is more complicated than the calculation of currents and voltages in the nominal fre...

  • Article
  • Open Access
15 Citations
3,758 Views
23 Pages

Efficient Design Optimization of Cable-Stayed Bridges: A Two-Layer Framework with Surrogate-Model-Assisted Prediction of Optimum Cable Forces

  • Yuan Ma,
  • Chaolin Song,
  • Zhipeng Wang,
  • Zuqian Jiang and ,
  • Bin Sun and
  • Rucheng Xiao
  • + 1 author+ 0 author

28 February 2024

Cable-stayed bridges have commonly been built for crossing large-span obstacles, such as rivers, valleys, and existing structures. Obtaining an optimum design for a cable-stayed bridge is challenging, due to the large number of design variables and d...

(This article belongs to the Special Issue Advances in Bridge Design and Construction: Technologies and Applications)
  • Article
  • Open Access
25 Citations
5,693 Views
14 Pages

A Simplified Model of Coaxial, Multilayer High-Temperature Superconducting Power Cables with Cu Formers for Transient Studies

  • Thai-Thanh Nguyen,
  • Woon-Gyu Lee,
  • Seok-Ju Lee,
  • Minwon Park and ,
  • Hak-Man Kim,
  • DuYean Won,
  • Jaeun Yoo and
  • Hyung Suk Yang
  • + 3 authors+ 0 author

22 April 2019

Bypassing transient current through copper (Cu) stabilizer layers reduces heat generation and temperature rise of high-temperature superconducting (HTS) conductors, which could protect HTS cables from burning out during transient conditions. The Cu l...

(This article belongs to the Special Issue Electric Power Systems Research 2019)
  • Article
  • Open Access
14 Citations
7,111 Views
23 Pages

Dynamic Model of a Novel Planar Cable Driven Parallel Robot with a Single Cable Loop

  • Antonio González-Rodríguez,
  • Andrea Martín-Parra,
  • Sergio Juárez-Pérez,
  • David Rodríguez-Rosa and ,
  • Francisco Moya-Fernández,
  • Fernando J. Castillo-García and
  • Jesús Rosado-Linares
  • + 2 authors+ 0 author

12 May 2023

Cable-Driven Parallel Robots (CDPRs) are a special kind of parallel manipulator that uses cables to control the position and orientation of the mobile platform or end effector. The use of cables instead of rigid links offers some advantages over thei...

(This article belongs to the Section Actuators for Robotics)
  • Article
  • Open Access
19 Citations
3,506 Views
18 Pages

A New Prestress Loss Calculation Model of Anchor Cable in Pile–Anchor Structure

  • Xing Gao,
  • Jinqing Jia,
  • Guoxiong Mei,
  • Xiaohua Bao and ,
  • Lihua Zhang and
  • Xiaoping Liao
  • + 1 author+ 0 author

11 April 2022

Pile–anchor structures are widely used in foundation excavation and slope reinforcement due to their safety and reliability. However, the pile–anchor structures have the common problem of the prestress loss of anchor cables, which may red...

  • Article
  • Open Access
17 Citations
3,882 Views
12 Pages

12 May 2021

Considering the interaction among anchor cable, frame beam and rock mass, a new model of prestress loss of anchor cable was established. The accuracy and applicability of the new model were verified by comparing the field monitoring data and the calc...

  • Article
  • Open Access
15 Citations
3,383 Views
22 Pages

23 February 2024

Insulation resistance (IR) is an essential metric indicating insulation conditions of extruded power cables. To deliver reliable IR simulation as a reference for practical cable inspection, in this paper, four IR degradation models for cross-linked p...

(This article belongs to the Special Issue Dielectric Insulation in Medium- and High-Voltage Power Equipment—Degradation and Failure Mechanism, Diagnostics, and Electrical Parameters Improvement)
  • Article
  • Open Access
8 Citations
4,988 Views
18 Pages

High-Frequency Modeling and Filter Design for PWM Drives with Long Cables

  • Lei Wang,
  • Yifan Zhang,
  • Muhammad Saqib Ali,
  • Guozhu Chen and ,
  • Josep M. Guerrero and
  • Juan C. Vasquez
  • + 1 author+ 0 author

22 February 2021

Aiming at the problems emerging in a pulse width modulation (PWM) drive system with long cables, the accurate modeling of power cables is the premise for predicting and analyzing these relevant phenomena, and a proper filter design is the key solutio...

(This article belongs to the Section A1: Smart Grids and Microgrids)
  • Article
  • Open Access
18 Citations
8,968 Views
34 Pages

Modeling of German Low Voltage Cables with Ground Return Path

  • Johanna Geis-Schroer,
  • Sebastian Hubschneider,
  • Lukas Held,
  • Frederik Gielnik and ,
  • Michael Armbruster,
  • Michael Suriyah and
  • Thomas Leibfried
  • + 2 authors+ 0 author

25 February 2021

In this contribution, measurement data of phase, neutral, and ground currents from real low voltage (LV) feeders in Germany is presented and analyzed. The data obtained is used to review and evaluate common modeling approaches for LV systems. An alte...

(This article belongs to the Special Issue Electric Distribution System Modeling and Analysis)
  • Article
  • Open Access
5 Citations
3,508 Views
15 Pages

Prediction Model for Trends in Submarine Cable Burial Depth Variation Considering Dynamic Thermal Resistance Characteristics

  • Zhenxing Hu,
  • Xueyong Ye,
  • Xiaokang Luo,
  • Hao Zhang and ,
  • Mingguang He,
  • Jiaxing Li and
  • Qian Li
  • + 2 authors+ 0 author

29 April 2024

Fault problems associated with submarine cables caused by variations in their burial depth are becoming increasingly prominent. To address the difficulty of detecting the burial depth of submarine cables and trends in its variation, a prediction mode...

(This article belongs to the Special Issue Advances in the Monitoring, Evaluation, Operation and Development of High-Penetration Renewable Energy Power Systems)
  • Article
  • Open Access
6 Citations
3,236 Views
19 Pages

Preliminary Multiphysics Modeling of Electric High-Voltage Cable of Offshore Wind-Farms

  • Fouad Ech-Cheikh,
  • Abdelghani Matine and
  • Monssef Drissi-Habti

29 August 2023

During manufacture, handling, transportation, installation and operation, mechanical overstress can affect the electrical and thermal properties of the conductor. As the wires in general are made of copper, which is a very plastically deforming mater...

(This article belongs to the Section A3: Wind, Wave and Tidal Energy)
  • Article
  • Open Access
5 Citations
4,883 Views
18 Pages

Design and Control of a Nonlinear Series Elastic Cable Actuator Based on the Hill Muscle Model

  • Yingbing Su,
  • Huaiwu Zou,
  • Hongrun Lu,
  • Bingshan Hu and
  • Hongliu Yu

22 February 2022

The bionic design of muscles is a research hotspot at present. Many researchers have designed bionic elastic actuators based on the Hill muscle model, and most of them include an active contraction element, passive contraction element and series elas...

(This article belongs to the Section Actuators for Robotics)
  • Article
  • Open Access
1 Citations
3,235 Views
16 Pages

11 September 2018

The knowledge about the behavior of cables is substantial in cases of transients or in cases of faults. However, there are only a few models that are tailored to the current requirements for calculations of transient phenomena in three-phase cable sy...

(This article belongs to the Section F: Electrical Engineering)
  • Proceeding Paper
  • Open Access
2,547 Views
16 Pages

A Model for the Thermal Behaviour of an Offshore Cable Installed in a J-Tube

  • Jeremy Arancio,
  • Ahmed Ould El Moctar,
  • Minh Nguyen Tuan,
  • Faradj Tayat and
  • Jean-Philippe Roques

14 September 2020

In the race for energy production, supplier companies are concerned by the thermal rating of offshore cables installed in a J-tube, not covered by IEC 60287 standards, and are now looking for solutions to optimize this type of system. This paper pres...

(This article belongs to the Proceedings of The First World Energies Forum—Current and Future Energy Issues)
  • Article
  • Open Access
5 Citations
1,853 Views
13 Pages

Simulation of High-Voltage Cable Sheath Current with a Panoramic Digital Tunnel Model

  • Zehua Pan,
  • Wei Guo,
  • Yekun Men,
  • Jing Cai and ,
  • Huachun Li,
  • Long Xiao,
  • Shiru Xu,
  • Yu Wang and
  • Yuanxi Li
  • + 4 authors+ 0 author

11 December 2024

Monitoring cable sheath current is crucial for guaranteeing the secure and efficient operation of high-voltage cable tunnels. In this study, a three-dimensional (3D) panoramic digital model of a tunnel in Beijing is modeled, a parallel cable sheath c...

(This article belongs to the Section Power Electronics)
  • Article
  • Open Access
6 Citations
3,743 Views
21 Pages

4 March 2021

Digital transformation of bridge engineering utilizes distinct modeling techniques to combine domain knowledge with digital information modeling. In particular, a long-span bridge is a key link in a transportation network, with more than 100 years of...

(This article belongs to the Special Issue Digital Model and Data-Driven Bridge Engineering: Plan, Design, Manufacturing, Construction, Safety and Maintenance)
  • Article
  • Open Access
14 Citations
8,121 Views
19 Pages

Study on Buried Depth Protection Index of Submarine Cable Based on Physical and Numerical Modeling

  • Xinlong Zheng,
  • Yongqiang Ge,
  • Zhifei Lu,
  • Chen Cao and ,
  • Peng Zhou,
  • Shiqiang Li and
  • Jiawang Chen
  • + 2 authors+ 0 author

The buried depth of submarine cables is very important to avoid damage on the cable from dropping and dragging anchors. This study focused on the actual engineering needs of submarine power cable protection and laying construction. In order to invest...

(This article belongs to the Section Ocean Engineering)
  • Article
  • Open Access
50 Citations
9,353 Views
23 Pages

This paper describes a study on the dynamic modeling and the motion simulation of an unmanned ocean platform to overcome the limitations of existing unmanned ocean platforms for ocean exploration. The proposed unmanned ocean vehicle combines an unman...

(This article belongs to the Special Issue Unmanned Marine Vehicles)
  • Article
  • Open Access
10 Citations
6,746 Views
23 Pages

4 May 2020

The preference of three-dimensional representation of underground cable wells from two-dimensional symbols is a developing trend, and three-dimensional (3D) point cloud data is widely used due to its high precision. In this study, we utilize the char...

(This article belongs to the Special Issue Point Cloud Processing in Remote Sensing)
  • Article
  • Open Access
47 Citations
10,473 Views
18 Pages

Dynamically Scaled Model Experiment of a Mooring Cable

  • Lars Bergdahl,
  • Johannes Palm,
  • Claes Eskilsson and
  • Jan Lindahl

The dynamic response of mooring cables for marine structures is scale-dependent, and perfect dynamic similitude between full-scale prototypes and small-scale physical model tests is difficult to achieve. The best possible scaling is here sought by me...

(This article belongs to the Special Issue Ocean Wave Energy Conversion)
  • Article
  • Open Access
8 Citations
4,453 Views
22 Pages

Dynamic Modeling and Optimization of Tension Distribution for a Cable-Driven Parallel Robot

  • Kai Wang,
  • Zhong Hua Hu,
  • Chen Shuo Zhang,
  • Zhi Wei Han and
  • Chao Wen Deng

25 July 2024

Cable-driven parallel robots (CDPRs) have been gaining much attention due to their many advantages over traditional parallel robots or serial robots, such as their markedly large workspace and lightweight design. However, one of the main issues that...

  • Article
  • Open Access
1 Citations
617 Views
16 Pages

Research on a Universal Analytical Thermal Circuit Model for Civil Electric Cables

  • Can Liu,
  • Kaiquan Mai,
  • Ningxia Yin,
  • Huanlao Liu and
  • Zhong Zheng

31 December 2025

The measured standard resistance at 20 °C (R20) is a critical indicator for evaluating the quality of electric cables. Utilizing a thermal circuit model allows for the rapid determination of R20. Focusing on civil electrical cables, this study co...

(This article belongs to the Section F: Electrical Engineering)
  • Article
  • Open Access
10 Citations
3,882 Views
14 Pages

29 November 2018

The tensile force on the hanger cables of a suspension bridge is an important indicator of the structural health of the bridge. Tensile force estimation methods based on the measured frequency of the hanger cable have been widely used. These methods...

(This article belongs to the Special Issue Computational Intelligence-Based Sensors)
  • Article
  • Open Access
6 Citations
2,529 Views
18 Pages

Research on the Diffusion Model of Cable Corrosion Factors Based on Optimized BP Neural Network Algorithm

  • Shiya Li,
  • Guowen Yao,
  • Wei Wang,
  • Xuanrui Yu and ,
  • Xuanbo He,
  • Chongyang Ran and
  • Hong Long
  • + 2 authors+ 0 author

Corrosion factors enter the cable via diffusion and penetration from the defect position of the cable or the connection position between the anchoring system and the cable section, seriously affecting the cable’s durability. Exploring the trans...

(This article belongs to the Special Issue Intelligent Building Health Monitoring and Assessment)
  • Article
  • Open Access
13 Citations
3,775 Views
14 Pages

This paper proposes the preliminary results on a novel control architecture based on model predictive control (MPC) for cable-driven parallel robots (CDPRs) and applies them to a three degrees of freedom (3-DOF) robot with a suspended configuration,...

(This article belongs to the Special Issue Dynamic Analysis of Multibody Mechanical Systems)
  • Article
  • Open Access
1 Citations
4,903 Views
18 Pages

Although many friction models have been developed by various researchers over the years, a general model does not exist yet. In this article, we present the work that was developed to identify and propose an empirical model that represents the behavi...

  • Article
  • Open Access
5 Citations
2,617 Views
15 Pages

Research on the Damage Diagnosis Model Algorithm of Cable-Stayed Bridges Based on Data Mining

  • Jie Liu,
  • Han Cheng,
  • Qingkuan Liu,
  • Hailong Wang and
  • Jianqing Bu

27 January 2023

To obtain an effective data mining method for cable-stayed bridge damage diagnosis, the algorithm of the cable-stayed bridge damage diagnosis model based on data mining was studied, and a data mining method is proposed. This method is oriented to the...

(This article belongs to the Special Issue Fatigue Damage Monitoring, Assessment and Reinforcement Method in Steel Bridge)
  • Article
  • Open Access
7 Citations
5,633 Views
21 Pages

Frequency-Dependent Pi Model of a Three-Core Submarine Cable for Time and Frequency Domain Analysis

  • Carlos Ruiz,
  • Gonzalo Abad,
  • Markel Zubiaga,
  • Danel Madariaga and
  • Joseba Arza

16 October 2018

In this paper, a Frequency-Dependent Pi Model (FDPi) of a three-core submarine cable is presented. The model is intended to be used for the representation of submarine cables in an Offshore Wind Power Plant (OWPP) scenario for both time and frequency...

(This article belongs to the Section F: Electrical Engineering)
  • Article
  • Open Access
15 Citations
4,646 Views
19 Pages

A Thermal Model for Three-Core Armored Submarine Cables Based on Distributed Temperature Sensing

  • Miguel Ángel González-Cagigal,
  • Juan Carlos del-Pino-López,
  • Alfonso Bachiller-Soler,
  • Pedro Cruz-Romero and
  • José Antonio Rosendo-Macías

29 June 2021

This paper presents a procedure for the derivation of an equivalent thermal network-based model applied to three-core armored submarine cables. The heat losses of the different metallic cable parts are represented as a function of the corresponding t...

  • Article
  • Open Access
3 Citations
1,867 Views
15 Pages

A Modified Bearing Capacity Model for Inclined Shallow Anchor Cable with Experimental Verification

  • Zhenhua Zhang,
  • Guojuan Xu,
  • Liangjun Dai,
  • Tao Cheng and ,
  • Banglu Xi,
  • Mingliang Chen and
  • Jiaqiang Yang
  • + 2 authors+ 0 author

9 December 2024

Most theoretical models of shallow anchor cables do not take the effect of anchor inclination into consideration, which is an important factor influencing load distribution, stress concentration, and failure mechanisms. In this paper, a modified bear...

(This article belongs to the Section Earth Sciences)
  • Article
  • Open Access
2 Citations
1,604 Views
21 Pages

Experimental Investigation and Modelling of the Incipient Fault of Low-Voltage XLPE Cables in Wet Environments

  • Chen Zeng,
  • Yunhe Wang,
  • Miaomiao Wu,
  • Yanru Lei and ,
  • Jing Yong and
  • Xiaojing Wang
  • + 1 author+ 0 author

19 April 2025

The study of incipient faults due to insulation defects in cables is crucial for preventing electrical fires and ensuring personal safety. However, research on incipient faults in low-voltage cables remains relatively underexplored compared to that o...

  • Article
  • Open Access
5 Citations
1,585 Views
17 Pages

28 July 2025

A cable-driven hybrid mobile robot is a kind of robot consisting of two modules connected in series, which uses multiple parallel cables to drive the moving platforms. Cable-driven robots benefit from a large workspace, low inertia, excellent dynamic...

(This article belongs to the Section Robotics, Mechatronics and Intelligent Machines)
  • Article
  • Open Access
2 Citations
3,312 Views
29 Pages

23 November 2021

In response to the climate emergency, new uses are plugged to low voltage (LV) electrical networks. The development of self-consumption complicates the LV grid operation, and force distribution system operators (DSOs) to better model and characterize...

(This article belongs to the Section A1: Smart Grids and Microgrids)
  • Article
  • Open Access
6 Citations
2,195 Views
24 Pages

24 January 2025

The hybrid cable-stayed suspension bridge is used to combine the advantages of cable-stayed and suspension bridges and hence has a broad prospect for application. The conventional simplified analytical models of the hybrid bridge are usually develope...

  • Article
  • Open Access
450 Views
23 Pages

Cable Defect Detection Using an Improved RT-DETR Model

  • Ziwei Yi,
  • Ying Fu,
  • Hua Xiang and
  • Tongxi Wang

22 September 2026

Small defect targets and complex backgrounds in transmission-line inspection images can limit detection accuracy, and existing detection models often incur substantial computational cost. To address these issues, this study proposes a cable defect de...

(This article belongs to the Section Sensing and Imaging)
  • Article
  • Open Access
2 Citations
1,296 Views
31 Pages

Nonlinear Dynamic Modeling of Flexible Cable in Overhead Bridge Crane and Trajectory Optimization Under Full-Constraint Conditions

  • Guangwei Yang,
  • Jiayang Wu,
  • Yutian Lei,
  • Yanan Cui and ,
  • Yifei Liu,
  • Lin Wan,
  • Gang Li,
  • Chunyan Long,
  • Yonglong Zhang and
  • Zehua Chen
  • + 5 authors+ 0 author

23 October 2025

Gantry cranes play a key role in modern industrial logistics. However, the traditional dynamic model based on the assumption of cable rigidity faces difficulty in accurately describing the complex swing characteristics of flexible cables, resulting i...

(This article belongs to the Special Issue Modeling and Nonlinear Control for Complex MIMO Mechatronic Systems)
  • Article
  • Open Access
4 Citations
2,587 Views
18 Pages

27 February 2025

Electric vehicles (EVs) rely on robust inverter-to-motor connections to ensure high-efficiency operation under the challenging conditions imposed by wide-bandgap (WBG) semiconductors. High switching frequencies and steep voltage rise times in WBG inv...

(This article belongs to the Section Electrical Machines and Drives)
  • Article
  • Open Access
5 Citations
3,510 Views
29 Pages

Dynamics Modeling and Motion Evaluation of a Near-Ground Tethered Balloon Cable System under Severe Wind Environments

  • Zhenhua Lai,
  • Mao Tang,
  • Xiaojin Hu,
  • Xin Shu and ,
  • Weicheng Huang and
  • Yongjun Pan
  • + 1 author+ 0 author

5 October 2024

Weather survival poses a significant challenge for the utilization of tethered balloons. The dynamic modeling of tethered balloon systems presents challenges due to the flexible nature of the cables and the intricate nature of gust forces. The presen...

(This article belongs to the Section Actuators for Surface Vehicles)

of 38