Skip to Content

82 Results Found

  • Article
  • Open Access
1 Citations
1,519 Views
19 Pages

An Enhanced Grid-Forming Control Strategy for Suppressing Magnetizing Inrush Current During Black Start of Wind-Storage Systems

  • Tieheng Zhang,
  • Yucheng Hou,
  • Yifeng Ding,
  • Yi Wan and ,
  • Xin Cao,
  • Derui Cai and
  • Jianhui Meng
  • + 2 authors+ 0 author

13 November 2025

Grid-forming wind-storage systems can serve as black-start power sources capable of autonomously establishing voltage and frequency references when the external grid is unavailable, thereby providing crucial support for rapid grid restoration. Howeve...

(This article belongs to the Special Issue New Trends in Topology and Control of Converters for Power Electronics Dominated Grids)
  • Article
  • Open Access
39 Citations
6,528 Views
27 Pages

19 March 2019

This paper proposes a digital sliding-mode controller for a DC-DC boost converter under constant power-loading conditions. The controller has been designed in two steps: the first step is to reach the sliding-mode regime while ensuring inrush current...

(This article belongs to the Special Issue Sliding Mode Control of Power Converters in Renewable Energy Systems)
  • Article
  • Open Access
26 Citations
8,615 Views
24 Pages

Inrush Current Control of High Power Density DC–DC Converter

  • Ahmed H. Okilly,
  • Namhun Kim and
  • Jeihoon Baek

19 August 2020

This paper presents a complete mathematical design of the main components of 2 kW, 54 direct current (DC)–DC converter stage, which can be used as the second stage of the two stages of alternating current (AC)–DC telecom power supply. In...

(This article belongs to the Special Issue Design and Control of Power Converters 2020)
  • Article
  • Open Access
1 Citations
1,089 Views
20 Pages

25 December 2025

To address the challenges of system failures and equipment damage caused by excitation inrush currents and overvoltages during no-load energization of high-speed locomotive transformers, a simulation model was developed utilizing PSCAD electromagneti...

  • Article
  • Open Access
498 Views
13 Pages

25 July 2026

Induction motor starting often causes voltage fluctuations due to high inrush current, which can impact system stability and power quality. To address this, smart inverters with power control functions and superconducting fault current limiters (SFCL...

(This article belongs to the Special Issue Leveraging Flexibility Resources to Enhance Renewable Energy Integration and Grid Stability)
  • Article
  • Open Access
20 Citations
11,386 Views
18 Pages

Digital Soft Start Implementation for Minimizing Start Up Transients in High Power DAB-IBDC Converter

  • P. Sathishkumar,
  • T. N. V. Krishna,
  • Himanshu,
  • Muhammad Adil Khan and ,
  • Kamran Zeb and
  • Hee-Je Kim
  • + 1 author+ 0 author

17 April 2018

The dual active bridge isolated bidirectional DC-DC converter (DAB-IBDC) is one of the prime converters used in dual active bridge renewable energy storage system (RESS) applications, particularly where a high-power density is required. The digital D...

(This article belongs to the Section D: Energy Storage and Application)
  • Feature Paper
  • Article
  • Open Access
2 Citations
1,822 Views
29 Pages

Measurement Verification of a Developed Strategy of Inrush Current Reduction for a Non-Loaded Three-Phase Dy Transformer

  • Marian Łukaniszyn,
  • Łukasz Majka,
  • Bernard Baron,
  • Barbara Kulesz and ,
  • Krzysztof Tomczewski and
  • Krzysztof Wróbel
  • + 1 author+ 0 author

28 October 2024

This article presents the measurement verification of a novel strategy for inrush current reduction in an unloaded three-phase Dy transformer. The strategy combines appropriate pre-magnetization of transformer cores with an original control switching...

(This article belongs to the Special Issue Design, Analysis, Optimization and Control of Electric Machines)
  • Article
  • Open Access
59 Views
24 Pages

5 November 2026

In cyber-physical power systems (CPPS), the inrush current generated during transformer reclosing can easily cause misjudgment of protection devices and thus serves as an important trigger for cascading failure propagation. Existing studies mostly re...

  • Article
  • Open Access
4 Citations
1,842 Views
15 Pages

Prediction of Transformer Residual Flux Based on J-A Hysteresis Theory

  • Qi Long,
  • Xu Yang,
  • Keru Jiang,
  • Changhong Zhang and ,
  • Mingchun Hou,
  • Yu Xin,
  • Dehua Xiong and
  • Xiongying Duan
  • + 3 authors+ 0 author

24 March 2025

Circuit breakers are effectively utilized for the controlled switching technique to mitigate inrush current when energizing an unloaded transformer. The core of the controlled switching technique is to obtain the appropriate closing angle based on th...

(This article belongs to the Section F: Electrical Engineering)
  • Article
  • Open Access
3 Citations
2,721 Views
19 Pages

25 November 2025

This paper presents a high-voltage step-up DC-DC converter with an active flexible loop based on the Boost topology. By combining interleaved technology, magnetic integration technology, and voltage doubling capacitor technology, the voltage step-up...

(This article belongs to the Collection Advanced Control and Applications of Power Electronics and Power Converters)
  • Article
  • Open Access
540 Views
28 Pages

Fractional-Order Reactive Power Control for Electro-Thermal-Constrained Fault Ride-Through of Grid-Forming Converters

  • Ye Tao,
  • Tao Lu,
  • Yue Yu,
  • Yanming Xiang and ,
  • Haizhou Ying,
  • Fan Li,
  • Shenghua Qiao,
  • Zhenshan Huang and
  • Yaci Yu
  • + 4 authors+ 0 author

Grid-forming converters are essential for low-inertia power systems. However, their semiconductor current and junction-temperature limits make them vulnerable to protection-triggered blocking and thermal overstress during severe voltage sags. Existin...

(This article belongs to the Section Engineering)
  • Article
  • Open Access
423 Views
48 Pages

Transformer Inrush Mitigation and Sequential Load Restoration in a Hybrid PV–BESS Microgrid Using Grid-Forming Black-Start Control—Case Study of a 31.59 MWp Photovoltaic Plant

  • Teodora Lazar,
  • Daria Ionescu,
  • Adina Milena Tatar,
  • Dan Cristian Lazar and ,
  • Otilia Nedelcu and
  • Dragos Pasculescu
  • + 1 author+ 0 author

30 September 2026

Hybrid PV–BESS microgrids represent a promising solution for enhancing energy resilience; however, the implementation of black-start functions in such architectures remains a complex challenge, particularly in the presence of medium-voltage tra...

(This article belongs to the Special Issue Application of Microgrids in Power System)
  • Article
  • Open Access
12 Citations
2,535 Views
18 Pages

A Control Strategy to Avoid Drop and Inrush Currents during Transient Phases in a Multi-Transmitters DIPT System

  • Wassim Kabbara,
  • Mohamed Bensetti,
  • Tanguy Phulpin,
  • Antoine Caillierez and ,
  • Serge Loudot and
  • Daniel Sadarnac
  • + 1 author+ 0 author

15 April 2022

Electrical Vehicles (EVs) have gained popularity in recent years in the automotive field. They are seen as a way to reduce the CO2 footprint of vehicles. Although EVs have witnessed significant advancement in recent years, they still have two major s...

(This article belongs to the Section E: Electric Vehicles)
  • Article
  • Open Access
26 Citations
5,833 Views
16 Pages

An Improved Commutation Prediction Algorithm to Mitigate Commutation Failure in High Voltage Direct Current

  • Xinnian Li,
  • Fengqi Li,
  • Shuyong Chen,
  • Yanan Li and ,
  • Qiang Zou,
  • Ziping Wu and
  • Shaobo Lin
  • + 2 authors+ 0 author

25 September 2017

Commutation failure is a common fault for line-commutated converters in the inverter. To reduce the possibility of commutation failure, many prediction algorithms based on alternating current (AC) voltage detection have already been implemented in hi...

(This article belongs to the Special Issue Emerging Power Electronics Technologies for Power Systems and Machine Drives)
  • Article
  • Open Access
7 Citations
4,641 Views
15 Pages

Temporary Fault Ride-Through Method in Power Distribution Systems with Distributed Generations Based on PCS

  • Jung-Hun Lee,
  • Seung-Gyu Jeon,
  • Dong-Kyu Kim,
  • Joon-Seok Oh and
  • Jae-Eon Kim

2 March 2020

The current practice of Distributed Generation (DG) disconnection for every fault in distribution systems has an adverse effect on utility and stable power trading when the penetration level of DGs is high. That is, in the process of fault detecting...

(This article belongs to the Special Issue Power Electronics Applications in Renewable Energy Systems)
  • Article
  • Open Access
8 Citations
4,910 Views
22 Pages

8 December 2021

When the electromagnetic transients occur in a power transformer, an inrush current is generated in its winding. The inrush current not only affects the performance of the transformer windings, but also affects the lifetime of the transformer. Many f...

  • Article
  • Open Access
13 Citations
4,494 Views
17 Pages

The occurrence of high-amplitude magnetizing inrush current during the energization of a transformer without load poses significant challenges to the stable operation of both the transformer and the power grid, potentially leading to malfunctions in...

(This article belongs to the Special Issue Advances in Modeling, Control and Protection of Power System Containing a High Proportion of Power Electronics)
  • Article
  • Open Access
6 Citations
6,657 Views
17 Pages

21 March 2016

This paper describes the reduced capacity of the inrush current suppressor using a matrix converter (MC) in a large-capacity wind power generation system (WPGS) with two squirrel-cage induction machines (SCIMs). These SCIMs are switched over dependin...

(This article belongs to the Special Issue Selected Papers from 5th Asia-Pacific Forum on Renewable Energy)
  • Article
  • Open Access
1,831 Views
22 Pages

15 August 2025

The controlled switching of capacitor banks when properly parameterized brings significant benefits to the bank, circuit breaker, and adjacent equipment by significantly reducing the levels of inrush currents. This article explores and analyzes the w...

(This article belongs to the Special Issue Modeling, Scheduling, Optimising, and Control of Power Grids and Integrated Energy Systems)
  • Article
  • Open Access
15 Citations
3,160 Views
16 Pages

23 February 2024

Currently, water inrush accidents in China’s coal mines are mainly under control, but occasionally, grave water inrush accidents still occur, causing significant casualties and economic losses. Existing studies have primarily focused on acciden...

(This article belongs to the Special Issue Innovative Technologies for Mine Water Treatment)
  • Article
  • Open Access
15 Citations
6,660 Views
19 Pages

18 May 2017

Three-phase active damping LCL-type grid-connected converters are usually used in distributed power generation systems. However, serious inrush current will be aroused when the grid-connected converter starts, especially in rectifier mode, if no effe...

(This article belongs to the Section F: Electrical Engineering)
  • Article
  • Open Access
9 Citations
5,249 Views
15 Pages

Hybrid Control-Based Closed-Loop Soft Start-Up Method for LLC Resonant Converters

  • Tian Gao,
  • Youzhi Wang,
  • Yongming Gao,
  • Gang Sun and ,
  • Haoyue Wang and
  • Jing Hou
  • + 1 author+ 0 author

7 November 2023

LLC resonant converters are prone to generating a large inrush current during the start-up process, which will cause damage to the resonant elements and threaten the safe operation of the circuit. In this study, we investigate the soft-start method t...

(This article belongs to the Special Issue Digital Control of Power Electronics)
  • Article
  • Open Access
3 Citations
4,737 Views
19 Pages

Variable Speed Drive DC-Bus Voltage Dip Proofing

  • Freeman Chiranga and
  • Lesedi Masisi

8 December 2021

This paper proposes a power electronic module that uses a switched capacitor for retaining the integrity of the dc-link voltage of a variable speed drive (VSD) during a 0.2 s short-term power interruption (STPI). Ride-through was achieved through swi...

(This article belongs to the Special Issue Power Electronic Converters: Control and Applications)
  • Article
  • Open Access
1 Citations
2,304 Views
17 Pages

Field Programmable Gate Array-Based Smart Switch to Avoid Inrush Current in PV Installations

  • Gerardo de J. Martínez-Figueroa,
  • Felipe Córcoles and
  • Santiago Bogarra

8 February 2024

This paper introduces an FPGA-based implementation of a smart switch designed to avoid inrush currents occurring during the connection of single-phase transformers utilized in grid-connected photovoltaic (PV) systems. The magnitude of inrush currents...

(This article belongs to the Topic Modern Power Systems and Units)
  • Article
  • Open Access
3 Citations
2,232 Views
19 Pages

Smart Switching in Single-Phase Grid-Connected Photovoltaic Power Systems for Inrush Current Elimination

  • Gerardo de J. Martínez-Figueroa,
  • Santiago Bogarra and
  • Felipe Córcoles

23 October 2023

Grid-connected photovoltaic (PV) power systems are one of the most promising technologies to address growing energy demand and ecological challenges. This paper proposes smart switching to mitigate inrush currents during the connection of single-phas...

(This article belongs to the Special Issue Advances in Resilient Operation, Optimization, and Control of Smart Grids and Microgrids)
  • Article
  • Open Access
5 Citations
7,285 Views
15 Pages

9 September 2016

This paper presents a seamless transition method for a droop-controlled inverter. The droop control is suitable to make the inverter work as a voltage source in both islanded and grid-connected modes, however, the transfer between theses modes can re...

(This article belongs to the Special Issue Microgrids 2016)
  • Article
  • Open Access
266 Views
24 Pages

8 October 2026

Solid-state circuit breakers (SSCBs) provide fast, arcless fault clearance, resulting in a longer service life compared to mechanical circuit breakers (MCBs) in DC grids. Black-start operations refers to the process of restarting a grid without an ex...

(This article belongs to the Special Issue The Application of Power Electronics Technology in Power and Energy Systems)
  • Article
  • Open Access
6 Citations
6,449 Views
19 Pages

Soft Start-Up Control Strategy for Dual Active Bridge Converter with a Supercapacitor

  • Min-Soo Kim,
  • Do-Hyun Kim,
  • Dong-Keun Jeong,
  • Jang-Mok Kim and
  • Hee-Je Kim

6 August 2020

Renewable energy needs are steadily on the rise. Bidirectional DC/DC converters are essential in charging and discharging various storage batteries, such as PV/ESS (photovoltaic/energy storage system). A dual active bridge (DAB) converter, in particu...

(This article belongs to the Section F: Electrical Engineering)
  • Article
  • Open Access
126 Views
25 Pages

A 1D CNN with Exact Grouped SHAP Attribution for Transformer Magnetizing Inrush Identification

  • Chenlei Li,
  • Junchi He,
  • Zhongli Wang,
  • Zheng Jia and ,
  • Junjun Lu,
  • Shoujiang He,
  • Shaofan Gu,
  • Jintao Yu,
  • Xianglong Gu and
  • Xiaozhen Zhao
  • + 5 authors+ 0 author

23 October 2026

Reliable transformer differential protection requires fast discrimination between magnetizing inrush and internal faults in the presence of residual flux, harmonic voltage, direct current (DC) bias, measurement noise, and current-transformer (CT) sat...

(This article belongs to the Special Issue Advances in Diagnostic Analysis, Strategic Management, and Proactive Maintenance of Electrical Equipment)
  • Article
  • Open Access
1 Citations
1,825 Views
18 Pages

Research on Opening Reignition Characteristics and Suppression Measures of 750 kV AC Filter Circuit Breakers

  • Jianguo Zhang,
  • Pengcheng Sha,
  • Feiyue Ma,
  • Bo Niu and ,
  • Xu Cai,
  • Hui Ni and
  • Junbo Deng
  • + 2 authors+ 0 author

6 January 2025

The operation of converter valves in converter stations often results in high reactive power consumption and harmonic generation, necessitating measures to maintain reactive power balance and ensure power quality. To achieve this, the filter bank cir...

(This article belongs to the Section F6: High Voltage)
  • Technical Note
  • Open Access
23 Citations
3,835 Views
12 Pages

Damage Characteristics and Mechanism of the 2017 Groundwater Inrush Accident That Occurred at Dongyu Coalmine in Taiyuan, Shanxi, China

  • Bin Luo,
  • Yajun Sun,
  • Zhimin Xu,
  • Ge Chen and ,
  • Li Zhang,
  • Weining Lu,
  • Xianming Zhao and
  • Huiqing Yuan
  • + 3 authors+ 0 author

31 January 2021

On 22 May 2017, a groundwater inrush accident occurred in the gob area of coal floor at Dongyu Coal Mine in Qingxu County, Shanxi Province, China. The water inrush accident caused great damage, among which six people died and the direct economic loss...

(This article belongs to the Special Issue Groundwater Sustainable Exploitation)
  • Article
  • Open Access
8 Citations
2,567 Views
22 Pages

Dynamic Performance Analysis and Fault Ride-Through Enhancement by a Modified Fault Current Protection Scheme of a Grid-Connected Doubly Fed Induction Generator

  • Rameez Akbar Talani,
  • Ghulam Sarwar Kaloi,
  • Aamir Ali,
  • Muhammad Ali Bijarani and ,
  • Ghulam Abbas,
  • Mohammed Hatatah,
  • Paolo Mercorelli and
  • Ezzeddine Touti
  • + 3 authors+ 0 author

29 January 2025

With the increase in reliance on doubly fed induction generator-based wind energy conversion systems (DFIG-WECSs), extracting maximum power from wind energy and enhancing fault ride-through (FRT) techniques meeting the grid code requirements is the f...

(This article belongs to the Section Electrical Machines and Drives)
  • Article
  • Open Access
438 Views
28 Pages

Active-support motor equipment combining a doubly fed induction machine (DFIM) with a flywheel energy storage unit possesses fast active and reactive power support capability, exhibiting promising prospects for enhancing power system stability. Howev...

(This article belongs to the Special Issue Smart Converters/Inverters for Grid Applications)
  • Article
  • Open Access
3 Citations
2,474 Views
22 Pages

Practical Experiments with a Ready-Made Strategy for Energizing a Suitable Pre-Magnetized Three-Column Three-Phase Dy Transformer in Unloaded State for Inrush Current Computations

  • Marian Łukaniszyn,
  • Łukasz Majka,
  • Bernard Baron,
  • Marcin Sowa and ,
  • Krzysztof Tomczewski and
  • Krzysztof Wróbel
  • + 1 author+ 0 author

10 May 2024

This article presents the results of an experimental verification of three-phase Dy transformer dynamics under no-load conditions. This study is motivated by previous ferroresonance analyses where the occurrence of inrush currents has been observed....

(This article belongs to the Section F1: Electrical Power System)
  • Article
  • Open Access
1 Citations
1,402 Views
15 Pages

A Low Inrush Current Pre-Charging Strategy of M3C with Improved Nearest Level Modulation

  • Rufei He,
  • Yikai Li,
  • Yumin Peng,
  • Yiming Ma and ,
  • Fanqi Huang,
  • Hailong Li and
  • Wei Luo
  • + 2 authors+ 0 author

31 May 2025

The modular multilevel matrix converter (M3C) can perform AC/AC conversion directly. However, M3C operation often requires a pre-charging process, which can be challenging due to the need for fast pre-charging with low inrush current. To address the...

(This article belongs to the Section F3: Power Electronics)
  • Article
  • Open Access
2 Citations
6,990 Views
11 Pages

An improved low-power hiccup-mode technology for short-circuit protection is proposed in this paper, which can effectively suppress short-circuit currents and greatly minimize the power dissipation of hiccup mode. The circuit can start normally after...

(This article belongs to the Topic Application of Innovative Power Electronic Technologies)
  • Article
  • Open Access
456 Views
27 Pages

8 October 2026

The increasing adoption of 270 VDC distribution in More-Electric Aircraft (MEA) demands improved power quality, voltage regulation, and dynamic performance from aircraft power conversion systems. However, conventional passive Transformer Rectifier Un...

(This article belongs to the Section Electrical Engineering Design)
  • Article
  • Open Access
7 Citations
2,095 Views
25 Pages

An Efficient Shunt Modulated AC Green Plug–Switched Filter Compensation Scheme for Nonlinear Loads

  • Albe M. Bloul,
  • Mohamad Abuhamdah,
  • Adel M. Sharaf,
  • Hamed H. Aly and
  • Jason Gu

18 May 2024

Nonlinear loads, crucial components of power system grids, pose a challenge due to harmonics injection. This work tackles this issue with a novel modified green plug–switched filter compensation scheme using fuzzy logic controllers. This innova...

(This article belongs to the Section A: Sustainable Energy)
  • Article
  • Open Access
4 Citations
3,524 Views
20 Pages

Grid Connection of a Squirrel-Cage Induction Generator Excited by a Partial Power Converter

  • Dominik A. Górski,
  • Grzegorz Dziechciaruk and
  • Grzegorz Iwański

16 January 2025

This article concerns the connection process of a squirrel-cage induction generator to the grid/microgrid. Typically, the generator is unexcited, and its connection to the grid is made directly via a switch. This connection causes a high inrush curre...

(This article belongs to the Special Issue Recent Advances in Power Quality Analysis and Robust Control of Renewable Energy Sources in Power Grids: 2nd Edition)
  • Article
  • Open Access
8 Citations
2,347 Views
15 Pages

The use of green energy to power ships in the marine industry has attracted increasing attention in recent years. This paper presents an inland river cruise ship supplied by a fuel cell (FC) as the main power source and a supercapacitor (SC) as the a...

(This article belongs to the Special Issue Advances in Marine Propulsion II)
  • Article
  • Open Access
11 Citations
3,529 Views
21 Pages

7 July 2023

The methodology and test results of a three-phase three-column transformer with a Dy connection group are presented in this paper. This study covers the dynamics of events that took place in the first period of the transient state caused by the energ...

(This article belongs to the Special Issue Problems during the Design and Testing of Instrument, Special and Power Transformers)
  • Article
  • Open Access
14 Citations
5,177 Views
18 Pages

Impact of Demand Side Response on a Commercial Retail Refrigeration System

  • Ibrahim M. Saleh,
  • Andrey Postnikov,
  • Corneliu Arsene,
  • Argyrios C. Zolotas and ,
  • Chris Bingham,
  • Ronald Bickerton and
  • Simon Pearson
  • + 2 authors+ 0 author

5 February 2018

The UK National Grid has placed increased emphasis on the development of Demand Side Response (DSR) tariff mechanisms to manage load at peak times. Refrigeration systems, along with HVAC, are estimated to consume 14% of the UK’s electricity and could...

  • Article
  • Open Access
1 Citations
532 Views
32 Pages

Real-Time Transient Voltage and Frequency Sensing Strategy for Resilience Enhancement of PV-Storage Systems in Weak Grids

  • Yu Ji,
  • Zixuan Liu,
  • Xin Gu,
  • Chenze Huo and ,
  • Zihan Zhang,
  • Song Tang,
  • Jun Mei and
  • Can Huang
  • + 3 authors+ 0 author

28 May 2026

Photovoltaic (PV)-storage systems operating in weak grids are affected by high grid impedance, transient voltage disturbances, and measurement noise, which can degrade frequency regulation, increase converter current stress, and impose high-frequency...

(This article belongs to the Section Electronic Sensors)
  • Proceeding Paper
  • Open Access
614 Views
10 Pages

This paper presents a comparative analysis of Flywheel Energy Storage Systems (FESS) employing Permanent Magnet Synchronous Machines (PMSMs) and AC Brushless DC (AC-BLDC) machines for fast and efficient frequency regulation. The study examines their...

(This article belongs to the Proceedings of The 34th Southern African Universities Power Engineering Conference (SAUPEC 2026))
  • Article
  • Open Access
387 Views
24 Pages

Power Path Dynamic Reconfiguration Method for Integrated Energy Storage-Soft Open Point

  • Pengfei Zhou,
  • Tao Xu,
  • Ziyi Lv,
  • Tianqu Hao and ,
  • Ke Chen,
  • Suhong Jiang and
  • Shidong Guo
  • + 2 authors+ 0 author

3 July 2026

Conventional soft open points (SOPs) suffer from limited transfer capacity during distribution network faults. To address this issue, this paper proposes an integrated energy storage system and soft open point (ES-SOP) along with a power path dynamic...

(This article belongs to the Special Issue Advanced Modeling and Control Strategies for Next-Generation Power Electronics and Energy Storage Systems)
  • Article
  • Open Access
630 Views
23 Pages

A Collaborative Grid-Connected Control Strategy for Heterogeneous Generator Groups Integrating Spatiotemporal Prediction Feedforward

  • Feng Lin,
  • Huili Ma,
  • Junfeng Li,
  • Kun Zhang and ,
  • Kaitong Guo and
  • Liansong Yu
  • + 1 author+ 0 author

Mobile emergency generators and mobile energy storage clusters are core flexible resources for the rapid recovery of critical loads in post-disaster distribution networks and the enhancement of resilience in isolated microgrids. However, due to the s...

(This article belongs to the Section Energy Supply and Sustainability)
  • Article
  • Open Access
2 Citations
691 Views
24 Pages

The large-scale integration of distributed energy resources poses numerous challenges to distribution networks. At present, multi-terminal flexible interconnection has become a key development trend for active distribution networks integrated with hi...

(This article belongs to the Special Issue Application of Intelligent Control and Optimization in Power, Energy, and Communication Systems)
  • Article
  • Open Access
26 Citations
9,567 Views
21 Pages

19 November 2012

A novel control strategy is proposed in this paper for the rotor side converter (RSC) of doubly-fed induction generator (DFIG)-based wind power generation systems. It is supposed to enhance the low-voltage ride-through (LVRT) capability of DFIGs duri...

  • Article
  • Open Access
4 Citations
4,900 Views
15 Pages

Decentralized Phase Shedding with Low Power Mode for Multiphase Converter

  • Marc Cousineau,
  • Martin Monroy,
  • William Lorenzi Pol,
  • Loic Hureau and ,
  • Guillaume Aulagnier,
  • Philippe Goyhenetche,
  • Eric Rolland and
  • Didier Flumian
  • + 3 authors+ 0 author

16 October 2021

With a multiphase converter, the phase-shedding function dedicated to maximizing the power efficiency, in a manner that is dependent on the load current, is always provided by a centralized controller that induces a Single Point of Failure (SPOF). Th...

(This article belongs to the Section F: Electrical Engineering)
  • Article
  • Open Access
15 Citations
3,537 Views
17 Pages

7 September 2021

This study proposes an advanced control scheme for the interlinking inverters of the hybrid AC/DC microgrids, which facilitates a seamless transition between grid-connected and stand-alone/islanding modes for the microgrid. Due to a nonlinear relatio...

(This article belongs to the Special Issue Solar PV and Wind Energy Systems for Energy Transition)

of 2