Skip to Content

500 Results Found

  • Communication
  • Open Access
27 Citations
6,253 Views
12 Pages

19 January 2021

The rapid estimation of the average shear rate encountered by the material as it flows along the screw elements of a corotating twin-screw extruder is a key point for many applications. In this paper, two methods of evaluation are presented that allo...

(This article belongs to the Special Issue Advances in Screw Processing of Polymeric Materials - In Memory of Professor James Lindsay White)
  • Article
  • Open Access
24 Citations
8,163 Views
19 Pages

22 October 2024

Compounding is an important step in processing base polymers and is used to incorporate various additives into a polymer. For this purpose, different screw elements are used for dispersive and distributive mixing on a co-rotating twin-screw extruder....

(This article belongs to the Section Polymer Processing and Engineering)
  • Article
  • Open Access
3 Citations
2,844 Views
34 Pages

7 February 2025

Today’s materials must meet high mechanical requirements while remaining cost-effective in production. This requires a homogeneous temperature and material distribution and splitting, as achieved by mixing elements in single-screw extrusion, wh...

(This article belongs to the Section Polymer Processing and Engineering)
  • Article
  • Open Access
3 Citations
4,589 Views
14 Pages

Due to their osteoconductive properties, allogenic bone screws made of human cortical bone have advantages regarding rehabilitation compared to other materials such as stainless steel or titanium. Since conventional screw drives like hexagonal or hex...

(This article belongs to the Section Trends in Bioengineering)
  • Article
  • Open Access
3 Citations
2,805 Views
12 Pages

4 August 2023

Enhancing the design of bone screw head sockets to prevent stripping and improve the torque required for smooth unscrewing is a significant challenge in orthopedic applications. This research aims to establish a quantitative methodology by integratin...

(This article belongs to the Section Biomaterials)
  • Article
  • Open Access
1 Citations
2,016 Views
14 Pages

Engagement and Stress Concentration Evaluation of a Novel Two-Part Compression Screw: A Preliminary Finite Element Analysis

  • Chia-Hao Hsu,
  • Chih-Kuang Wang,
  • Yan-Hsiung Wang,
  • Sung-Yen Lin and ,
  • Cheng-Chang Lu,
  • Yin-Chih Fu,
  • Hsuan-Ti Huang,
  • Chung-Hwan Chen and
  • Pei-Hsi Chou
  • + 4 authors+ 0 author

Background/Objectives: This novel compression screw design offers potential benefits due to its two-part structure and can be used for various bone types, much like a conventional single-piece compression screw. However, full engagement may not alway...

(This article belongs to the Special Issue Fundamentals of Orthopaedic Biomechanics: Implants, AI, and Innovation in Surgery)
  • Article
  • Open Access
11 Citations
3,405 Views
16 Pages

Oblique lumbar interbody fusion (OLIF) can be combined with different screw instrumentations. The standard screw instrumentation is bilateral pedicle screw fixation (BPSF). However, the operation is time consuming because a lateral recumbent position...

(This article belongs to the Special Issue Biomedical and Bioengineering Technology: Current Applications in Sports Monitoring and Health Care)
  • Article
  • Open Access
6 Citations
5,589 Views
14 Pages

Screw Stress Distribution in a Clavicle Fracture with Plate Fixation: A Finite Element Analysis

  • Angelo Alito,
  • Domenico Fenga,
  • Giada Tropeano,
  • Demetrio Milardi and ,
  • Danilo Leonetti,
  • Alba Migliorato,
  • Adriana Tisano,
  • Danilo D’Andrea and
  • Vincenzo Filardi
  • + 4 authors+ 0 author

Clavicle midshaft fractures are mostly treated surgically by open internal reduction with a superior or anteroinferior plate and screws or by intramedullary nailing. Screw positioning plays a critical role in determining the stress distribution. Ther...

(This article belongs to the Special Issue Application of Computational Models in Optimizing Orthopedic Surgical Treatment)
  • Article
  • Open Access
9 Citations
3,295 Views
10 Pages

Finite Element Analysis of Channel Screw and Conventional Plate Technique in Tile B2 Pelvic Fracture

  • Dejian Li,
  • Hanru Ren,
  • Xu Zhang,
  • Rongguang Ao and ,
  • Chengqing Yi and
  • Baoqing Yu
  • + 1 author+ 0 author

10 March 2023

Objective: This study aims to analyze the biomechanical characteristics of tile B2 pelvic fractures using finite element analysis when the superior ramus of the pubis was fixed by a plate or hollow screws in standing and sitting positions, respective...

(This article belongs to the Section Methodology, Drug and Device Discovery)
  • Article
  • Open Access
4 Citations
1,559 Views
10 Pages

5 July 2025

Background/Objectives: This study evaluates the structural strength of various fixation models for distal tibial fractures using finite element analysis, comparing the biomechanical performance of different interlocking and blocking screw configurati...

(This article belongs to the Section Orthopedics)
  • Article
  • Open Access
12 Citations
7,634 Views
16 Pages

10 November 2021

Cortical bone trajectory (CBT) is increasingly used in spinal surgery. Although there are many biomechanical studies, the biomechanical effect of CBT in combination with traditional pedicle screws is not detailed. Therefore, the purpose of this study...

(This article belongs to the Section Applied Biosciences and Bioengineering)
  • Article
  • Open Access
5 Citations
4,183 Views
11 Pages

19 October 2020

This study developed a numerical simulation to understand bone mechanical behavior and micro-crack propagation around a fixation screw with severe mandibular defects. A mandible finite element (FE) model was constructed in a rabbit with a right unila...

(This article belongs to the Special Issue Challenges and Advances in Monitoring and Diagnosis in Medical Sciences)
  • Article
  • Open Access
1 Citations
1,815 Views
23 Pages

Inclusion of Muscle Forces Affects Finite Element Prediction of Compression Screw Pullout but Not Fatigue Failure in a Custom Pelvic Implant

  • Yuhui Zhu,
  • Ata Babazadeh-Naseri,
  • Matthew R. W. Brake,
  • John E. Akin and ,
  • Geng Li,
  • Valerae O. Lewis and
  • Benjamin J. Fregly
  • + 2 authors+ 0 author

12 November 2024

Custom implants used for pelvic reconstruction in pelvic sarcoma surgery face a high complication rate due to mechanical failures of fixation screws. Consequently, patient-specific finite element (FE) models have been employed to analyze custom pelvi...

(This article belongs to the Section Applied Biosciences and Bioengineering)
  • Article
  • Open Access
2,660 Views
12 Pages

28 August 2022

Bone resorption around implants is quite common, and the maturity and popularization of computer-aided design and computer-aided manufacturing (CAD/CAM) technology have made the use of aftermarket abutment screws more widespread. This study aimed to...

  • Article
  • Open Access
2 Citations
2,202 Views
11 Pages

Finite Element Analysis of Stress Distribution in Canine Lumbar Fractures with Different Pedicle Screw Insertion Angles

  • Ziyao Zhou,
  • Xiaogang Shi,
  • Jiahui Peng,
  • Xiaoxiao Zhou and ,
  • Liuqing Yang,
  • Zhijun Zhong,
  • Haifeng Liu,
  • Guangneng Peng,
  • Chengli Zheng and
  • Ming Zhang
  • + 5 authors+ 0 author

19 July 2025

Pedicle screw fixation is a critical technique for stabilizing lumbar fractures in canines, yet the biomechanical implications of insertion angles remain underexplored. This study aims to identify optimal screw trajectories by analyzing stress distri...

(This article belongs to the Special Issue Advanced Therapy in Companion Animals—2nd Edition)
  • Feature Paper
  • Article
  • Open Access
1 Citations
543 Views
13 Pages

5 June 2026

Background/Objectives: Due to the inherent rotational instability of the proximal fragment in unstable basicervical intertrochanteric (IT) fractures, the biomechanical effect of lag screw position may differ from that observed in typical unstable IT...

(This article belongs to the Special Issue Clinical Advances in Lower Limb Trauma and Orthopedic Surgery: From Bench to Bedside)
  • Article
  • Open Access
326 Views
16 Pages

A Comparative Finite Element Study on the Biomechanical Effect of Implant Crown Screw Access Channel Filled by Direct vs. Indirect Restoration Materials

  • Abdulsalam Al Zahawi,
  • Kale Mohammad,
  • Rawa Ibrahim,
  • Hawzhen Mohammed and ,
  • Laith A. Sabri,
  • Rawaz Mohammed,
  • Shilan Nawzad Dawood,
  • Rozhina Kamal,
  • Sara Rashid and
  • Ranjdar Mahmood Talabani
  • + 5 authors+ 0 author

2 October 2026

Background: The restorative material used to seal the screw access channel in screw-retained implant-supported crowns may influence the biomechanical behavior and mechanical performance of the restoration. Objective: To evaluate the influence of diff...

(This article belongs to the Collection Oral Implantology: Current Aspects and Future Perspectives)
  • Article
  • Open Access
18 Citations
8,493 Views
13 Pages

Finite Element Study of a Threaded Fastening: The Case of Surgical Screws in Bone

  • J. A. López-Campos,
  • A. Segade,
  • E. Casarejos,
  • J. R. Fernández and ,
  • J. A. Vilán and
  • P. Izquierdo
  • + 1 author+ 0 author

11 August 2018

This paper studies the stress state of a threaded fastening by using Finite Element (FE) models, applied to surgical screws in cortical bone. There is a general interest in studying the stress states induced in the different elements of a joint cause...

(This article belongs to the Special Issue Symmetry and Engineering Design)
  • Article
  • Open Access
23 Citations
6,439 Views
9 Pages

18 May 2020

In this study, we evaluate the influence of implant neck wall thickness and abutment screw size on alveolar bone and implant component biomechanical responses using nonlinear finite element (FE) analysis. Twelve internal hexagon Morse taper implant&n...

(This article belongs to the Special Issue Implant Dentistry)
  • Article
  • Open Access
289 Views
27 Pages

Optimization of a Screw Conveying Seed-Metering Device for Pregerminated Rice Seeds Based on a Bonded Discrete Element Model

  • Hongxu Chen,
  • Yanan Xu,
  • Chaoyu Wang,
  • Guohui Tang and ,
  • Wenshu Han,
  • Han Tang and
  • Jinwu Wang
  • + 2 authors+ 0 author

12 October 2026

To address the problems of seed damage and poor seeding uniformity in UAV-based direct rice seeding, this study investigated the optimization of a screw conveying seed-metering device for pregerminated rice seeds. A discrete element model based on th...

(This article belongs to the Section Seed Science and Technology)
  • Article
  • Open Access
7 Citations
4,590 Views
18 Pages

5 April 2021

The aim of this study was to analyze the spinal stability and safety after posterior spinal fusion with various fixation segments and screw types in patients with an osteoporotic thoracolumbar burst fracture based on finite element analysis (FEA). To...

(This article belongs to the Special Issue Recent Developments and Emerging Trends in Biomechanics)
  • Article
  • Open Access
7 Citations
4,023 Views
17 Pages

21 August 2024

Screw piles (often referred to as helical piles) are widely used to resist axial and lateral loads as deep foundations. Multi-helix piles experience complex interactions between the plates which depend on the soil properties, pile stiffness, helix di...

(This article belongs to the Special Issue Recent Advances in Geotechnical Engineering (2nd Edition))
  • Article
  • Open Access
4 Citations
3,103 Views
17 Pages

Optimizing Screw Fixation in Total Hip Arthroplasty: A Deep Learning and Finite Element Analysis Approach

  • Jacob Stroud,
  • Emily T. Yan,
  • Jacob Anthony,
  • Kyle Walker and
  • Chung-Hyun Goh

28 March 2025

Total hip arthroplasty (THA) is a widely performed procedure to restore hip function in patients with degenerative joint diseases. Traditional “press-fit” fixation methods rely on sufficient bone quality for stability, but additional scre...

(This article belongs to the Special Issue Artificial Intelligence and Computer Technologies in Sports and Healthcare)
  • Article
  • Open Access
11 Citations
4,812 Views
14 Pages

Biomechanical Assessment of Vertebroplasty Combined with Cement-Augmented Screw Fixation for Lumbar Burst Fractures: A Finite Element Analysis

  • Yueh-Ying Hsieh,
  • Yi-Jie Kuo,
  • Chia-Hsien Chen,
  • Lien-Chen Wu and ,
  • Chang-Jung Chiang and
  • Chun-Li Lin
  • + 1 author+ 0 author

21 March 2020

A hybrid fixation method, using a combination of vertebroplasty and cement-augmented screws, has been demonstrated as a useful technique for securing osteoporotic burst fractures. The purpose of this study was to assess changes in the range of motion...

(This article belongs to the Special Issue Orthopaedic and Rehabilitation Engineering)
  • Article
  • Open Access
5 Citations
3,893 Views
13 Pages

Evaluation of Stress Distribution of Maxillary Anterior Segment during en Masse Retraction Using Posterior Mini Screw: A Finite Element Study

  • Meer Juned Ali,
  • Amit Bhardwaj,
  • Mohammad Shoyab Khan,
  • Farhan Alwadei and ,
  • Khalid Gufran,
  • Abdullah Saad Alqahtani,
  • Nasser Raqe Alqhtani,
  • Mohammed Alasqah,
  • Abdulaziz Mohammad Alsakr and
  • Rawda Omar Alghabban
  • + 5 authors+ 0 author

14 October 2022

The current study aimed to perceive and estimate the distribution of stress generated by the forces on the maxillary anterior teeth during orthodontic retraction using the bilateral mini screw implant. Finite element models were generated from the th...

(This article belongs to the Special Issue Skeletal Anchorage and Digital Design Appliances in Contemporary Orthodontics)
  • Article
  • Open Access
1 Citations
4,558 Views
10 Pages

An Efficient Distalization Technique Using Coil Springs and Mini Screws—A Finite Element Analysis

  • Ryo Hamanaka,
  • Runa Yamaguchi,
  • Daiki Kuga,
  • Sachio Jinnai and ,
  • Hiroya Komaki,
  • Jun-ya Tominaga and
  • Noriaki Yoshida
  • + 2 authors+ 0 author

14 October 2022

Background: More efficient molar distalization is demanded in orthodontics to shorten treatment times. In the present study, we propose a novel technique to improve force distribution to distalize molars more efficiently by using open-coil springs an...

(This article belongs to the Special Issue Clinical Applications of Orthodontic TSADs (Temporary Skeletal Anchorage Devices))
  • Article
  • Open Access
1 Citations
2,100 Views
38 Pages

Biomechanical Effects of Platform Diameter and Screw Length in an Abutment-Free Tissue-Level Implant System Compared with a Ti-Base Configuration: 3D Finite Element Analysis

  • Aliona Dodi,
  • Alecsandru Ionescu,
  • Mihaela Anca Marin,
  • Emil Nuțu and ,
  • Vlad Gabriel Vasilescu,
  • Ana Maria Cristina Țâncu,
  • Toma Lucian Ciocan and
  • Marina Imre
  • + 3 authors+ 0 author

This finite element analysis compared a tissue-level implant with an engaging Ti-base to abutment-free, direct-to-implant, tissue-level configurations (3.7 mm and 4.5 mm platforms; short and long retention screws) to examine how platform width and sc...

(This article belongs to the Special Issue Biomechanical Studies and Biomaterials in Dentistry (2nd Edition))
  • Article
  • Open Access
311 Views
19 Pages

Uncoupled Auxiliary S2-Alar-Iliac Screws in Long Lumbopelvic Constructs: Exploratory Finite Element Analysis and Preliminary Clinical Experience

  • Celal Ozbek Cakir,
  • Murat Baloglu,
  • Ulkun Unlu Unsal,
  • Hakan Millet and ,
  • Erdal Yayla,
  • Eser Pala and
  • Ismail Bozkurt
  • + 2 authors+ 0 author

24 September 2026

Background and Objectives: In this study, uncoupled auxiliary trans-sacroiliac (UATS) screws were evaluated as a mechanically independent adjunct to conventional S2-alar-iliac (S2AI) fixation in long lumbopelvic constructs. We assessed their explorat...

(This article belongs to the Special Issue Clinical Advancements in Spine Surgery: Best Practices and Outcomes)
  • Article
  • Open Access
11 Citations
3,429 Views
13 Pages

Lumbar spondylolysis involves anatomical defects of the pars interarticularis, which causes instability during motion. The instability can be addressed through instrumentation with posterolateral fusion (PLF). We developed a novel pedicle screw W-typ...

(This article belongs to the Special Issue Computational Biomechanics)
  • Article
  • Open Access
2 Citations
4,698 Views
13 Pages

10 March 2023

Introduction: The aim of this study was to determine the placement of an orthodontic mini-screw (OMS) and the length of an anterior retraction hook (ARH) with en masse retraction. Continuous maxillary tooth movement pattern was simulated by finite el...

(This article belongs to the Special Issue Clinical Applications of Orthodontic TSADs and CBCT)
  • Article
  • Open Access
4 Citations
4,335 Views
16 Pages

The Screw Driving Sounding (SDS) is a recently developed in-situ testing method for soil/site characterisation. To better understand the mechanism of testing, it is essential to create a simulation model for the SDS test to assist in better understan...

(This article belongs to the Special Issue Recent Advances in Geotechnical Engineering)
  • Article
  • Open Access
1,849 Views
18 Pages

Damage Mechanism Analysis of the Connecting Screw of Turbine Disk-Drum Assembly

  • Haijun Wang,
  • Shengxu Wang,
  • Pu Xue,
  • Yongxin Guo and
  • Liang Jiang

19 July 2024

The turbine disk-drum is one of the key components of an aero-engine and its assembly is connected with high-strength refined screws. But due to the uncoordinated rotation and deformation, the screws have abnormal wear damage. Through detailed contac...

(This article belongs to the Section Machines Testing and Maintenance)
  • Article
  • Open Access
1,279 Views
20 Pages

Numerical Simulation and Optimization of Novel and Efficient Screw Structures for Spinnable Pitch

  • Wenzhen Peng,
  • Zhiwei Shi,
  • Wenzheng Jiang,
  • Guodong Zhang and ,
  • Huitao Cai,
  • Bo Zhu and
  • Kun Qiao
  • + 2 authors+ 0 author

3 November 2025

In recent years, there has been a growing shift toward the use of screw extruders in the pitch modification process. To further improve the mixing efficiency of twin-screw extruders in pitch processing, this study focuses on redesigning the mixing el...

  • Feature Paper
  • Article
  • Open Access
24 Citations
10,351 Views
24 Pages

18 April 2018

A fractured stainless steel 3.5 mm proximal humerus internal locking system (PHILOS) plate and screws were investigated in this paper. This plate was used for ankle arthrodesis of a 68-year-old female with a right ankle deformity. Both the plate and...

(This article belongs to the Special Issue Failure Analysis of Biometals)
  • Article
  • Open Access
4 Citations
2,329 Views
11 Pages

19 July 2023

Wooden partitions are extensively used as formwork for pouring concrete in wood–concrete composite beams, especially in the restoring of wood structures. However, limited research has been conducted on the shear properties of pitched screw conn...

(This article belongs to the Section Construction and Building Materials)
  • Article
  • Open Access
2 Citations
3,048 Views
13 Pages

9 February 2023

To investigate the feasibility of using absorbable Mg alloy pedicle screws for atlantoaxial dislocation fixation, four types of Mg alloy pedicle screws of different thread forms were designed, and simulation analysis of the pull-out force was perform...

(This article belongs to the Section Biobased and Biodegradable Metals)
  • Article
  • Open Access
8 Citations
5,122 Views
14 Pages

Comparative Biomechanical Study of Screw Fixation Techniques in Periacetabular Osteotomy

  • Mahsan Bakhtiarinejad,
  • Amirhossein Farvardin,
  • Ryan J. Murphy,
  • Robert B. Grupp and ,
  • John E. Tis,
  • Paul D. Sponseller and
  • Mehran Armand
  • + 2 authors+ 0 author

Periacetabular osteotomy (PAO) is a common surgical treatment for developmental dysplasia of the hip. To obtain the optimal method of fixation during PAO, different screw fixation techniques have been proposed for stabilizing the acetabular fragment....

(This article belongs to the Section Gait and Posture Biomechanics)
  • Article
  • Open Access
5 Citations
7,749 Views
29 Pages

Biomechanical Behavior of a Variable Angle Locked Tibiotalocalcaneal Construct

  • Farah Hamandi,
  • Gerard Simon,
  • Richard Laughlin and
  • Tarun Goswami

This paper examines the mechanics of the tibiotalocalcaneal construct made with a PHILOS plating system. A failed device consisting of the LCP plate and cortical, locking, and cannulated screws was used to perform the analysis. Visual, microstructure...

(This article belongs to the Special Issue Assessments and Advances in Bone Regeneration, Therapies and Healing)
  • Article
  • Open Access
2 Citations
2,320 Views
15 Pages

19 June 2024

The bearing capacity of fiber-reinforced plastic (FRP) helical screw piles is determined by the lesser of the breaking load at the bolted joint and the resistance provided by the screw tip area. In this study, compression and tensile tests were perfo...

(This article belongs to the Section Polymer Processing and Engineering)
  • Article
  • Open Access
12 Citations
4,996 Views
19 Pages

24 June 2020

Syndesmosis injuries account for approximately 20% of ankle fractures that require surgery. Although multiple surgical options are available, all of them are based on metal screws. Serious complications that arise when applying metal screws include s...

(This article belongs to the Special Issue Orthopaedic and Rehabilitation Engineering II)
  • Article
  • Open Access
21 Citations
3,719 Views
15 Pages

24 September 2019

In high-speed precision machining, thermal deformation caused by temperature rise affects the accuracy stability of the machine tool to a significant extent. In order to reduce the thermal deformation of ball screws and improve the accuracy, a new ad...

(This article belongs to the Section Materials Simulation and Design)
  • Article
  • Open Access
3 Citations
3,504 Views
19 Pages

Analytical, Stochastic and Experimental Solution of the Osteosynthesis of the Fifth Metatarsal by Headless Screw

  • Kateřina Vlčková,
  • Karel Frydrýšek,
  • Vojtěch Bajtek,
  • Jiří Demel and ,
  • Leopold Pleva,
  • Miroslav Havlíček,
  • Jana Pometlová,
  • Roman Madeja,
  • Jiří Kratochvíl and
  • Jana Vaculová
  • + 9 authors+ 4 authors

25 September 2022

This paper evaluates the various approaches to strength and stiffness analysis of fracture osteosynthesis using a headless Herbert screw. The problem has been extensively addressed using several scientific approaches, namely the analytical approach,...

(This article belongs to the Section Biomedical Engineering)
  • Article
  • Open Access
4 Citations
3,510 Views
12 Pages

Application of Inverse Neural Networks for Optimal Pretension of Absorbable Mini Plate and Screw System

  • Alex Bernardo Pimentel-Mendoza,
  • Lázaro Rico-Pérez,
  • Manuel Javier Rosel-Solis,
  • Luis Jesús Villarreal-Gómez and ,
  • Yuridia Vega and
  • José Omar Dávalos-Ramírez
  • + 1 author+ 0 author

2 February 2021

Mandibular fractures are common facial lesions typically treated with titanium plate and screw systems; nevertheless, this material is associated with secondary effects. Absorbable material for implants is an alternative to titanium, but there are al...

(This article belongs to the Section Applied Biosciences and Bioengineering)
  • Review
  • Open Access
21 Citations
8,733 Views
34 Pages

Process Simulation of Twin-Screw Granulation: A Review

  • Tony Bediako Arthur and
  • Nejat Rahmanian

Twin-screw granulation has emerged as a key process in powder processing industries and in the pharmaceutical sector to produce granules with controlled properties. This comprehensive review provides an overview of the simulation techniques and appro...

(This article belongs to the Special Issue Pharmaceutical Solids: Advanced Manufacturing and Characterization)
  • Article
  • Open Access
1 Citations
1,167 Views
17 Pages

4 January 2026

Objective: Lumbar interbody fusion (LIF) is widely used to treat degenerative spinal disorders; however, both fixation strategies and interbody Cage designs still present biomechanical limitations. This study aimed to develop a posterior lumbar inter...

  • Article
  • Open Access
7 Citations
1,609 Views
17 Pages

Bearing Characteristics of Screw-Groove Piles: Model Test and Numerical Analysis

  • Huiling Zhao,
  • Yousheng Deng,
  • Ziying Zhuang and
  • Zhigang Yao

26 November 2024

Screw-groove piles, a new type of precast pile, are economically and environmentally friendly and improve the load-bearing performance of piles through a unique screw-groove structure. To reveal the load-transfer characteristics and bearing mechanism...

(This article belongs to the Section Construction and Building Materials)
  • Article
  • Open Access
14 Citations
3,170 Views
21 Pages

Simulation and Experimental Validation on the Effect of Twin-Screw Pulping Technology upon Straw Pulping Performance Based on Tavares Mathematical Model

  • Huiting Cheng,
  • Yuanjuan Gong,
  • Nan Zhao,
  • Luji Zhang and ,
  • Dongqing Lv and
  • Dezhi Ren
  • + 1 author+ 0 author

9 November 2022

Rice straw is waste material from agriculture as a renewable biomass resource, but the black liquor produced by straw pulping causes serious pollution problems. The twin-screw pulping machine was designed by Solidworks software and the straw breakage...

(This article belongs to the Special Issue Biomass Conversion and Organic Waste Utilization)
  • Article
  • Open Access
599 Views
29 Pages

Shear Behaviour of Polyurethane Screw-Glued and Serrated Steel Plate Flange-to-Web Joints in Ribbed CLT Panels

  • Elza Briuka,
  • Ernests Kiops,
  • Dmitrijs Serdjuks,
  • Janis Sliseris and ,
  • Andris Berzins,
  • Arturs Zīverts,
  • Ulvis Skadins,
  • Janis Fabriciuss and
  • Vjaceslavs Lapkovskis
  • + 4 authors+ 0 author

29 September 2026

The present study investigates the shear behaviour of screw-glued and mechanical flange-to-web connections intended for cross-laminated timber (CLT) ribbed panels, with the aim of improving composite behaviour and enhancing the structural performance...

(This article belongs to the Special Issue Advanced Composite Materials and Design for Structural Safety and Sustainability)
  • Article
  • Open Access
3 Citations
1,342 Views
24 Pages

4 October 2025

Screw piles are widely used in infrastructure, such as railways, highways, and ports, etc., owing to their large pile resistance compared to unthreaded piles. While most screw pile research focuses on single pile behavior under rotational installatio...

(This article belongs to the Special Issue Structural Engineering in Building)
  • Article
  • Open Access
8 Citations
4,399 Views
12 Pages

Biomechanical Comparison of Posterior Fixation Combinations with an Allograft Spacer between the Lateral Mass and Pedicle Screws

  • Soo-Bin Lee,
  • Hwan-Mo Lee,
  • Tae-Hyun Park,
  • Sung Jae Lee and ,
  • Young-Woo Kwon,
  • Seong-Hwan Moon and
  • Byung Ho Lee
  • + 2 authors+ 0 author

19 October 2020

Background: There are a few biomechanical studies that describe posterior fixation methods with pedicle screws (PS) and lateral mass screws (LMS); the combination of both screw types and their effect on an allograft spacer in a surgically treated cer...

(This article belongs to the Special Issue Musculoskeletal Research: Biomechanics and Biomaterials for the Treatment of Orthopedic Diseases)

of 10