Skip to Content

253 Results Found

  • Article
  • Open Access
2 Citations
2,119 Views
21 Pages

Blood Pressure Estimation Through Pulse Wave Analysis Using Features Extracted from Carotid Diameter Distension Waveforms

  • Lirui Xu,
  • Zhenhua Li,
  • Pan Xia,
  • Chen Zhang and ,
  • Lidong Du,
  • Wei Tian and
  • Zhen Fang
  • + 2 authors+ 0 author

8 March 2026

Blood pressure estimation through pulse wave analysis (PWA) aims to establish the relationship between features of pulse waveforms and blood pressure. This study is the first to investigate the connection between features of carotid artery diameter w...

(This article belongs to the Special Issue Wearable Sensors and Systems for Continuous Health Monitoring)
  • Article
  • Open Access
16 Citations
9,068 Views
15 Pages

Pulse Wave Analysis Method of Cardiovascular Parameters Extraction for Health Monitoring

  • Ji Jin,
  • Xingguang Geng,
  • Yitao Zhang,
  • Haiying Zhang and
  • Tianchun Ye

Objective: A pulse waveform is regarded as an information carrier of the cardiovascular system, which contains multiple interactive cardiovascular parameters reflecting physio-pathological states of bodies. Hence, multiple parameter analysis is incre...

(This article belongs to the Section Digital Health)
  • Article
  • Open Access
8 Citations
5,847 Views
14 Pages

Pioneering Data Processing for Convolutional Neural Networks to Enhance the Diagnostic Accuracy of Traditional Chinese Medicine Pulse Diagnosis for Diabetes

  • Wei-Chang Yeh,
  • Chen-Yi Kuo,
  • Jia-Ming Chen,
  • Tien-Hsiung Ku and ,
  • Da-Jeng Yao,
  • Ya-Chi Ho and
  • Ruei-Yu Lin
  • + 2 authors+ 0 author

Traditional Chinese medicine (TCM) has relied on pulse diagnosis as a cornerstone of healthcare assessment for thousands of years. Despite its long history and widespread use, TCM pulse diagnosis has faced challenges in terms of diagnostic accuracy a...

(This article belongs to the Section Biosignal Processing)
  • Article
  • Open Access
7 Citations
5,784 Views
12 Pages

Machine-Learning Classification of Pulse Waveform Quality

  • Te Ouyoung,
  • Wan-Ling Weng,
  • Ting-Yu Hu,
  • Chia-Chien Lee and ,
  • Li-Wei Wu and
  • Hsin Hsiu
  • + 1 author+ 0 author

8 November 2022

Pulse measurements made using wearable devices can aid the monitoring of human physiological condition. Accurate estimation of waveforms is often difficult for nonexperts; motion artifacts may occur during tonometry measurements when the skin–s...

(This article belongs to the Special Issue Wearable Sensor Technologies for Physiological and Environmental Monitoring)
  • Article
  • Open Access
1 Citations
210 Views
38 Pages

Subject-Specific Cardiovascular Signatures Revealed by Arterial Pulse Signals in Patients with Heart Diseases—Part I: General Cases

  • Md Mahfuzur Rahman,
  • Mamun Hasan,
  • Jennifer F. May,
  • John M. Herre and ,
  • Leryn J. Reynolds and
  • Zhili Hao
  • + 1 author+ 0 author

29 October 2026

Background/Objectives: This study evaluates whether cardiovascular (CV) parameters derived from noninvasive arterial pulse signals can capture subject-specific physiological characteristics and longitudinal changes in patients with diverse heart dise...

(This article belongs to the Section Clinical Diagnosis and Prognosis)
  • Article
  • Open Access
16 Citations
4,484 Views
21 Pages

Load Characteristics in Taylor Impact Test on Projectiles with Various Nose Shapes

  • Jun-Cheng Li,
  • Gang Chen,
  • Feng-Lei Huang and
  • Yong-Gang Lu

27 April 2021

This study focused on the impact load produced by a projectile and its potential application in the Taylor impact test. Taylor impact tests were designed and carried out for projectiles with four types of nose shapes, and the impact deformation chara...

  • Article
  • Open Access
1 Citations
201 Views
28 Pages

Subject-Specific Cardiovascular Signatures Revealed by Arterial Pulse Signals in Patients with Heart Diseases—Part II: Special Cases

  • Mamun Hasan,
  • Md Mahfuzur Rahman,
  • Jennifer F. May,
  • John M. Herre and ,
  • Leryn J. Reynolds and
  • Zhili Hao
  • + 1 author+ 0 author

22 October 2026

Aim: This study evaluates whether cardiovascular (CV) parameters derived from noninvasive arterial pulse signals can reveal subject-specific characteristics in patients with atypical CV dynamics. Methods: Seven special-case patients—including a...

(This article belongs to the Section Clinical Diagnosis and Prognosis)
  • Article
  • Open Access
16 Citations
8,906 Views
8 Pages

Recovery Time of Silicon Photomultiplier with Epitaxial Quenching Resistors

  • Jiali Jiang,
  • Jianquan Jia,
  • Tianqi Zhao,
  • Kun Liang and ,
  • Ru Yang and
  • Dejun Han
  • + 1 author+ 0 author

The silicon photomultiplier (SiPM) is a promising semiconductor device for low-level light detection. The recovery time, or the photon-counting rate of the SiPM is essential for high-flux photon detection in such applications as photon counting compu...

  • Article
  • Open Access
21 Citations
12,683 Views
20 Pages

Machine Learning Techniques for Arterial Pressure Waveform Analysis

  • Vânia G. Almeida,
  • João Vieira,
  • Pedro Santos,
  • Tânia Pereira and ,
  • H. Catarina Pereira,
  • Carlos Correia,
  • Mariano Pego and
  • João Cardoso
  • + 3 authors+ 0 author

2 May 2013

The Arterial Pressure Waveform (APW) can provide essential information about arterial wall integrity and arterial stiffness. Most of APW analysis frameworks individually process each hemodynamic parameter and do not evaluate inter-dependencies in the...

  • Article
  • Open Access
1,121 Views
12 Pages

Optimizing Diabetes Diagnosis Through Pulse Waveform Analysis and Data Mining

  • Shun-Chang Chang,
  • Ruei-Yu Lin,
  • Shiaw-Meng Chang,
  • Li-Chun Teng and ,
  • Tien-Hsiung Ku,
  • Wei-Chang Yeh and
  • Chia-Ling Huang
  • + 2 authors+ 0 author

The objective of this study is to develop a robust diabetes diagnosis model by employing four distinct algorithms as weak learners: the Random Forest algorithm, SVM algorithm, KNN algorithm, and Decision Tree algorithm. The selection of the optimal c...

(This article belongs to the Section Biosignal Processing)
  • Article
  • Open Access
10 Citations
3,773 Views
17 Pages

Modeling and Analysis of an Echo Laser Pulse Waveform for the Orientation Determination of Space Debris

  • Hyung-Chul Lim,
  • Zhong-Ping Zhang,
  • Ki-Pyoung Sung,
  • Jong Uk Park and ,
  • Simon Kim,
  • Chul-Sung Choi and
  • Mansoo Choi
  • + 2 authors+ 0 author

21 May 2020

Orientation information of space debris is required to improve the orbital prediction accuracy for mitigation or elimination of a significant threat to not only human space activities but also operational satellites. Obtaining orientation information...

  • Article
  • Open Access
2,479 Views
11 Pages

Pulsed ytterbium-doped fiber amplifiers (YDFA) with ns-level signal width are important devices for obtaining high-power pulsed lasers. When some components in the amplifier are ineffective, e.g., the isolator or fiber is damaged, extra feedback ligh...

(This article belongs to the Special Issue Narrow Linewidth Laser Sources and Their Applications)
  • Article
  • Open Access
2 Citations
2,735 Views
24 Pages

An Analysis of Arterial Pulse Wave Time Features and Pulse Wave Velocity Calculations Based on Radial Electrical Bioimpedance Waveforms in Patients Scheduled for Coronary Catheterization

  • Kristina Lotamõis,
  • Tiina Uuetoa,
  • Andrei Krivošei,
  • Paul Annus and ,
  • Margus Metshein,
  • Marek Rist,
  • Sulev Margus,
  • Mart Min and
  • Gert Tamberg
  • + 4 authors+ 0 author

The monitoring of peripheral electrical bioimpedance (EBI) variations is a promising method that has the potential to replace invasive or burdensome techniques for cardiovascular measurements. Segmental or continuous recording of peripheral pulse wav...

  • Article
  • Open Access
5 Citations
3,332 Views
13 Pages

15 September 2023

In this study, a high sampling rate data acquisition system with the ability to provide timestamp, pulse shape information, and waveform simultaneously under a sub megahertz pulse counting rate was developed for radiation diagnostics for magnetic con...

(This article belongs to the Special Issue Science and Technology of Advanced Electronics, Sensing Systems and AI Applied to Society: Including Collections from the Latest Papers of KRIS 2023)
  • Feature Paper
  • Article
  • Open Access
6 Citations
3,444 Views
15 Pages

1 December 2021

The harmonic analysis (HA) of arterial radial pulses in humans has been widely investigated in recent years for clinical applications of traditional Chinese medicine. This study aimed at establishing the validity of carrying out HA on synchronous per...

(This article belongs to the Special Issue Diagnosis, Treatment and Prognosis of Cardiovascular Disease)
  • Article
  • Open Access
5 Citations
1,588 Views
33 Pages

6 November 2025

Motion artifacts (MA) are a key factor affecting the accuracy of a measured arterial pulse signal at rest. This paper presents a generalized time–frequency method for MA removal that is built upon a single-degree-of-freedom (SDOF) model of MA,...

(This article belongs to the Special Issue Advances in Biosignal Sensing and Signal Processing)
  • Feature Paper
  • Article
  • Open Access
3 Citations
4,356 Views
15 Pages

The Cascade of High-Voltage Pulsed Current Sources

  • Weigang Dong,
  • Lei Chen,
  • Jian Qiu,
  • Haozheng Shi and ,
  • Hui Zhao and
  • Kefu Liu
  • + 1 author+ 0 author

28 February 2024

Currently, pulsed adders are used as pulsed voltage sources maturely. However, their use as pulsed current sources is significantly limited due to circuit impedance and the characteristics of power devices. This paper presents a simple yet effective...

(This article belongs to the Special Issue Advances in Pulsed-Power and High-Power Electronics)
  • Article
  • Open Access
4 Citations
4,166 Views
19 Pages

Physics of Within-Tissue Wave Propagation Generated by Pulse Propagation in the Carotid Artery

  • Daniela Tommasin,
  • Annette Caenen,
  • Benedict Verhegghe,
  • Steve Greenwald and
  • Patrick Segers

18 July 2019

(1) Background: We aimed to assess the validity of laser Doppler vibrometry (LDV) as an emerging method to measure the local pulse wave velocity (PWV) from skin displacement generated by the pressure pulse inside an underlying artery. (2) Methods: A...

(This article belongs to the Section Applied Biosciences and Bioengineering)
  • Article
  • Open Access
6 Citations
3,371 Views
13 Pages

Research on Electromagnetic Susceptibility of Electronic Modules in Component-Level HEMP PCI Test

  • Chuanbao Du,
  • Dewei Xia,
  • Quan Huang,
  • Congguang Mao and ,
  • Zhitong Cui,
  • Wenxiao Fang and
  • Xin Nie
  • + 2 authors+ 0 author

15 February 2022

The study of electromagnetic sensitivity of electronic modules is crucial for the selection of a component-level pulse current injection (PCI) waveform, which will determine whether a component-level PCI test is equivalent to a system-level pulse ill...

(This article belongs to the Special Issue Electromagnetic Transients in Large-Scale Renewable Energy System: Model, Method, Simulation, Measurement and Suppressing Techniques)
  • Article
  • Open Access
44 Citations
6,542 Views
14 Pages

Actuating Voltage Waveform Optimization of Piezoelectric Inkjet Printhead for Suppression of Residual Vibrations

  • Muhammad Ali Shah,
  • Duck-Gyu Lee,
  • Bo Yeon Lee,
  • Nam Woon Kim and ,
  • Hyojin An and
  • Shin Hur
  • + 1 author+ 0 author

29 September 2020

After a piezoelectric inkjet printhead jets the first droplet, the actuating membrane still vibrates, creating residual vibrations in the ink channel, which can degrade the inkjet printhead performance. For suppressing these vibrations, an optimized...

  • Article
  • Open Access
4 Citations
2,539 Views
23 Pages

24 October 2022

Time-frequency analysis in waveform engineering can be applied to many detection and imaging systems, such as radar, sonar, and ultrasound to improve their Signal-to-Noise Ratio (SNR). Recently, photoacoustic imaging systems have attracted researcher...

(This article belongs to the Section A: Computer Science)
  • Review
  • Open Access
8 Citations
4,103 Views
30 Pages

Recent Advancements in Optical Fiber Sensors for Non-Invasive Arterial Pulse Waveform Monitoring Applications: A Review

  • Jing Wen Chew,
  • Soon Xin Gan,
  • Jingxian Cui,
  • Wen Di Chan and ,
  • Sai T. Chu and
  • Hwa-Yaw Tam
  • + 1 author+ 0 author

The awareness of the importance of monitoring human vital signs has increased recently due to the outbreak of the COVID-19 pandemic. Non-invasive heart rate monitoring devices, in particular, have become some of the most popular tools for health moni...

(This article belongs to the Special Issue Novel Advances in Optical Fiber Gratings)
  • Article
  • Open Access
6 Citations
4,437 Views
13 Pages

Delayed Discharge Bridging Two Sputtering Modes from Modulated Pulsed Power Magnetron Sputtering (MPPMS) to Deep Oscillation Magnetron Sputtering (DOMS)

  • Masaomi Sanekata,
  • Hiroshi Nishida,
  • Tatsuya Watabe,
  • Yuki Nakagomi and ,
  • Yoshihiro Hirai,
  • Nobuo Nishimiya,
  • Masahide Tona,
  • Hiroaki Yamamoto,
  • Naoyuki Hirata and
  • Kiyokazu Fuke
  • + 8 authors+ 3 authors

21 April 2021

Delayed discharges due to electrical breakdown are observed in modulated pulsed pow er magnetron sputtering (MPPMS) plasma of titanium. The delayed discharge, which is remarkable with decreasing argon gas pressure, transforms the discharge current wa...

(This article belongs to the Special Issue Feature Papers in Plasma Sciences)
  • Article
  • Open Access
3 Citations
2,623 Views
11 Pages

7 December 2023

Magnetic pulse welding (MPW) is a joining method that uses Lorentz force generated from an electromagnetic field. This method not only has the advantage of not causing thermal deformation of the material and no by-products compared to the method of j...

(This article belongs to the Section Industrial Electronics)
  • Article
  • Open Access
6 Citations
2,771 Views
25 Pages

12 June 2023

The utilization of intermittent sampling jamming can engender a lofty verisimilitude false target cluster that exhibits coherence with the transmitted signal. Such an assemblage bears the hallmarks of both suppression jamming and deceitful jamming, c...

(This article belongs to the Special Issue Advanced Radar Signal Processing and Applications)
  • Article
  • Open Access
33 Citations
4,918 Views
18 Pages

30 September 2022

This article aims to propose an algorithm for the automatic recognition of selected radar signals. The algorithm can find application in areas such as Electronic Warfare (EW), where automatic recognition of the type of intra-pulse modulation or the t...

(This article belongs to the Collection Navigation Systems and Sensors)
  • Article
  • Open Access
18 Citations
3,832 Views
17 Pages

30 March 2023

The existing research proposes an intra-pulse frequency agile radar waveform with “active” anti-jamming characteristics. It uses the discontinuity and periodicity of the interrupted-sampling repeater jamming and combines the anti-jamming...

  • Article
  • Open Access
7 Citations
2,174 Views
15 Pages

23 August 2024

The orthogonal frequency-division multiplexing (OFDM) mode with a linear frequency modulation (LFM) signal as the baseband waveform has been widely studied and applied in multiple-input multiple-output (MIMO) radar systems. However, its high sidelobe...

(This article belongs to the Section Radar Sensors)
  • Article
  • Open Access
1,011 Views
15 Pages

An Intelligent Suppression Method for Interference Pulses in Partial Discharge Detection of Transformers Based on Waveform Feature Recognition

  • Shaoyu Chen,
  • Ziyue Xu,
  • Zekai Lai,
  • Zhulu Wang and ,
  • Hongli Wang,
  • Xinjian Wu,
  • Ran Yao,
  • Weidong Xie and
  • Haibao Mu
  • + 4 authors+ 0 author

10 November 2025

High-frequency current detection of partial discharge (PD) at transformers on-site faces complex noise interference, which severely impacts the accuracy of PD detection. To address this issue, an intelligent interference suppression algorithm for PD...

(This article belongs to the Special Issue Polyphase Insulation and Discharge in High-Voltage Technology)
  • Article
  • Open Access
5 Citations
3,379 Views
15 Pages

Using Arterial Pulse and Laser Doppler Analyses to Discriminate between the Cardiovascular Effects of Different Running Levels

  • Yi-Jia Lin,
  • Chia-Chien Lee,
  • Tzu-Wei Huang,
  • Wei-Chun Hsu and ,
  • Li-Wei Wu,
  • Chen-Chun Lin and
  • Hsin Hsiu
  • + 2 authors+ 0 author

10 April 2023

Background and Aims: Running can induce advantageous cardiovascular effects such as improved arterial stiffness and blood-supply perfusion. However, the differences between the vascular and blood-flow perfusion conditions under different levels of en...

(This article belongs to the Special Issue Applications, Wearables and Sensing Technology in Sports and Physical Activity)
  • Article
  • Open Access
14 Citations
6,008 Views
20 Pages

Data-Driven Approach to Benthic Cover Type Classification Using Bathymetric LiDAR Waveform Analysis

  • Teemu Kumpumäki,
  • Pekka Ruusuvuori,
  • Ville Kangasniemi and
  • Tarmo Lipping

12 October 2015

A data-driven method for describing the benthic cover type based on full-waveform bathymetric LiDAR data analysis is presented. The waveform of the bathymetric LiDAR return pulse is first modeled as a sum of three functions: a Gaussian pulse represen...

  • Article
  • Open Access
1 Citations
2,819 Views
10 Pages

Generation of a High-Intensity Temporal Step Waveform Based on Stimulated Brillouin Scattering

  • Zhaohong Liu,
  • Tiantian Luo,
  • Yifu Chen,
  • Sensen Li and ,
  • Shaowen Li,
  • Rong Fan,
  • Yulei Wang and
  • Zhiwei Lu
  • + 3 authors+ 0 author

This paper proposes a method based on stimulated Brillouin scattering (SBS) for reshaping a temporal Gaussian waveform into a temporal high-intensity step waveform. The theoretical analysis showed that the reshaped temporal waveform depended on the p...

  • Article
  • Open Access
19 Citations
8,297 Views
17 Pages

11 January 2023

The human radial artery pulse carries a rich array of biomedical information. Accurate detection of pulse signal waveform and the identification of the corresponding pulse condition are helpful in understanding the health status of the human body. In...

(This article belongs to the Section Wearables)
  • Article
  • Open Access
1,077 Views
12 Pages

First-in-Human Prospective, Observational, and Comparative Clinical Study of Simultaneous Invasive and Non-Invasive Intracranial Pressure Pulse Wave Monitoring

  • Indre Lapinskiene,
  • Edvinas Chaleckas,
  • Vilma Putnynaite,
  • Laimonas Bartusis and ,
  • Yasin Hamarat,
  • Aidanas Preiksaitis,
  • Mindaugas Serpytis,
  • Vytautas Petkus,
  • Saulius Vosylius and
  • Arminas Ragauskas
  • + 5 authors+ 0 author

24 February 2026

Monitoring intracranial pressure (ICP) dynamics is critical for the management of traumatic brain injury, stroke, other neurosurgical conditions, and cerebral blood flow autoregulation; however, invasive ICP monitoring carries risks such as infection...

(This article belongs to the Section Electronic Sensors)
  • Article
  • Open Access
4 Citations
3,382 Views
21 Pages

19 September 2023

The design of transmitting waveforms is an effective way to improve the detection performance of sonar systems. For the problem of high-range sidelobe when designing reverberation-resistant waveforms, this paper proposes a high-resolution wideband co...

  • Article
  • Open Access
5 Citations
3,779 Views
15 Pages

24 December 2024

Nickel (Ni) single-layer coatings were electrodeposited under varying pulse periods (T), duty cycles (θ), and average current densities (iav) using four distinct pulse current waveforms: rectangular (Rec), triangular (Tri), ramp-up triangular (...

  • Article
  • Open Access
4 Citations
2,621 Views
13 Pages

This paper proposes a steady-state analysis of the asymmetrical pulse-width-modulated series resonant converter, commonly employed under light load conditions for effective voltage regulation. The proposed method achieves precise and explicit convert...

(This article belongs to the Special Issue Innovative Technologies in Power Converters, 2nd Edition)
  • Article
  • Open Access
2 Citations
3,051 Views
31 Pages

A Unified Analysis of DC–DC Converters’ Current Stress

  • Michael Njoroge Gitau,
  • Lebogang Masike and
  • Grain P. Adams

11 April 2023

There is always a need to analyze current signals generated by various DC–DC converters. For example, to determine the current stress experienced by semiconductor devices and to evaluate active and reactive power consumption in converters. The...

(This article belongs to the Special Issue Modeling, Control, and Optimization of Power Electronic Converters)
  • Article
  • Open Access
1 Citations
3,549 Views
22 Pages

29 December 2024

Three-phase diode bridge rectifiers are widely employed in various industrial applications because of their inherent simplicity, robustness, low electromagnetic interference and good overall performance. However, their use causes harmonic distortion...

(This article belongs to the Special Issue Energy, Electrical and Power Engineering: 3rd Edition)
  • Article
  • Open Access
21 Citations
6,157 Views
15 Pages

4 March 2017

Detection of foreign matter in cleaned cotton is instrumental to accurately grading cotton quality, which in turn impacts the marketability of the cotton. Current grading systems return estimates of the amount of foreign matter present, but provide n...

(This article belongs to the Section Physical Sensors)
  • Article
  • Open Access
526 Views
21 Pages

A low-voltage alternating current (AC) field (20 V peak-to-peak, 1 kHz) was superimposed on a conventional direct current (DC) electrospinning configuration in order to test whether the shape of that perturbation measurably alters fiber formation. A...

  • Article
  • Open Access
10 Citations
6,561 Views
17 Pages

This paper describes a design approach to a control system of power supply for high-voltage electrochemical processes such as plasma electrolytic oxidation (PEO) or high-voltage anodising (HVA), which require alternating polarisation pulses up to 750...

  • Article
  • Open Access
5 Citations
3,476 Views
19 Pages

2 March 2024

Ultra-long-distance and high-precision lightning location technology is an important means to realize low-cost and wide-area lightning detection. This paper carried out research on the high-precision location technology of very-low-frequency (VLF) li...

(This article belongs to the Topic Advances in Multi-Scale Geographic Environmental Monitoring: Theory, Methodology and Applications)
  • Article
  • Open Access
2,050 Views
23 Pages

Deep Learning-Enabled Diagnosis of Abdominal Aortic Aneurysm Using Pulse Volume Recording Waveforms: An In Silico Study

  • Sina Masoumi Shahrbabak,
  • Byeng Dong Youn,
  • Hao-Min Cheng,
  • Chen-Huan Chen and ,
  • Shih-Hsien Sung,
  • Ramakrishna Mukkamala and
  • Jin-Oh Hahn
  • + 2 authors+ 0 author

1 November 2025

This paper investigates the feasibility of diagnosing abdominal aortic aneurysm (AAA) via deep learning (DL)-enabled analysis of non-invasive arterial pulse waveform signals. We generated arterial blood pressure (BP) and pulse volume recording (PVR)...

(This article belongs to the Special Issue Wearable Sensors for Human Health Monitoring in Clinical and Ecologic Scenarios)
  • Article
  • Open Access
15 Citations
4,184 Views
18 Pages

A Waveform Design for Integrated Radar and Jamming Based on Smart Modulation and Complementary Coding

  • Huabin Yan,
  • Shiyuan Zhang,
  • Xingyu Lu,
  • Jianchao Yang and ,
  • Lunhao Duan,
  • Ke Tan and
  • Hong Gu
  • + 2 authors+ 0 author

25 July 2024

Waveform design for integrated radar and jamming is generally based on the concept of shared waveform, which uses jamming signals without typical radar signal characteristics for detection. Existing waveforms have shown limited design flexibility, hi...

(This article belongs to the Topic Radar Signal and Data Processing with Applications)
  • Article
  • Open Access
6 Citations
3,000 Views
12 Pages

Estimation Accuracy of the Electric Field in Cable Insulation Based on Space Charge Measurement

  • Norikazu Fuse,
  • Shosuke Morita,
  • Satoru Miyazaki,
  • Toshihiro Takahashi and
  • Naohiro Hozumi

5 July 2022

Space charge measurement accuracy is crucial when assessing the suitability of cables for high-voltage direct current (DC) systems. This study assembled state-of-the-art analysis technologies, including time-domain deconvolution, to mark electric fie...

(This article belongs to the Section F: Electrical Engineering)
  • Article
  • Open Access
6 Citations
5,308 Views
16 Pages

19 July 2018

Waveform lidar provides both geometric and waveform properties from the entire returned signals. The waveform analysis is an important process to extract the attributes of the reflecting surface from the waveform. The proposed method analyzes the geo...

(This article belongs to the Special Issue Future Trends and Applications for Airborne Laser Scanning)
  • Article
  • Open Access
6 Citations
3,309 Views
19 Pages

23 September 2021

This paper investigates partial discharge (PD) characteristics that lead to the erosion of silicone rubber (SR) polymer under AC stress and DC stress of both polarities. The experiments are performed on high temperature vulcanized (HTV) SR material s...

(This article belongs to the Special Issue Dielectric and Electrical Insulation Measurements)
  • Article
  • Open Access
21 Citations
4,711 Views
17 Pages

26 May 2023

Electrical treeing is one of the main degradation mechanisms in high-voltage polymeric insulation. Epoxy resin is used as insulating material in power equipment such as rotating machines, power transformers, gas-insulated switchgears, and insulators,...

(This article belongs to the Special Issue Modification and Study on the Properties of Epoxy Resin)
  • Article
  • Open Access
11 Citations
3,191 Views
24 Pages

Machine Learning Analyses Revealed Distinct Arterial Pulse Variability According to Side Effects of Pfizer-BioNTech COVID-19 Vaccine (BNT162b2)

  • Chun-Chao Chen,
  • Che-Kai Chang,
  • Chun-Chih Chiu,
  • Tsung-Yeh Yang and ,
  • Wen-Rui Hao,
  • Cheng-Hsin Lin,
  • Yu-Ann Fang,
  • William Jian,
  • Min-Huei Hsu and
  • Hsin Hsiu
  • + 7 authors+ 2 authors

17 October 2022

Various adverse events and complications have been attributed to COVID-19 (coronavirus disease 2019) vaccinations, which can affect the cardiovascular system, with conditions such as myocarditis, thrombosis, and ischemia. The aim of this study was to...

(This article belongs to the Section Cardiovascular Medicine)

of 6