Skip to Content

674 Results Found

  • Article
  • Open Access
6 Citations
4,223 Views
16 Pages

Coherence-Length Effects in Fast Atom Diffraction at Grazing Incidence

  • María Silvia Gravielle,
  • Jorge Esteban Miraglia and
  • Leandro Frisco

27 November 2018

Coherence properties of projectiles, found relevant in ion-atom collisions, are investigated by analyzing the influence of the degree of coherence of the atomic beam on interference patterns produced by grazing-incidence fast-atom diffraction (GIFAD...

(This article belongs to the Special Issue Recent Advances in Ion-Impact Atomic Collisions: Experiment, Theory and Applications)
  • Review
  • Open Access
23 Citations
5,808 Views
14 Pages

Methods of Atmospheric Coherence Length Measurement

  • Ming Li,
  • Pengxin Zhang and
  • Jiawei Han

15 March 2022

Free-space optical (FSO) communication possesses the advantages of high security, large information capacity, high-speed transmission, small terminal size, low power consumption, easy and flexible deployment, etc. It is a promising communication tech...

(This article belongs to the Special Issue Optics in Information and Communication Technologies)
  • Perspective
  • Open Access
5 Citations
4,070 Views
4 Pages

A short coherence length is a distinctive feature of many cases of unconventional superconductivity. While in conventional superconductors, it is many orders of magnitude larger than the basic inter-particle distance, a short coherence length is comm...

(This article belongs to the Special Issue From Quantum Paraelectric/Ferroelectric Perovskite Oxides to High Temperature Superconducting Copper Oxides -- In Honor of Professor K.A. Müller for His Lifework)
  • Article
  • Open Access
2 Citations
2,609 Views
14 Pages

Measurement of Atmospheric Coherence Length from a Shack–Hartmann Wavefront Sensor with Extended Sources

  • Junrui Zhang,
  • Yuling Zhao,
  • Leqiang Yang,
  • Jie Liu and ,
  • Wenyu Wang,
  • Zhengwei Li,
  • Jianli Wang and
  • Tao Chen
  • + 3 authors+ 0 author

18 December 2024

Free Space Optical Communication (FSOC) is a wireless communication method that utilizes laser beams for high speed and secure data transmission. Its performance is affected by various factors, among which atmospheric turbulence causes random fluctua...

(This article belongs to the Special Issue Recent Advances in Optical Turbulence)
  • Article
  • Open Access
94 Views
26 Pages

6 November 2026

Horizontal coherence length informs array aperture design and coherent processing performance assessment. This study presents a method for measuring horizontal coherence length along an array in the presence of interference and background noise. Suba...

(This article belongs to the Special Issue Advanced Research in Underwater Acoustic Signal Processing)
  • Article
  • Open Access
3 Citations
3,220 Views
21 Pages

13 June 2023

Nickelate superconductors, R1−xAxNiO2 (where R is a rare earth metal and A = Sr, Ca), experimentally discovered in 2019, exhibit many unexplained mysteries, such as the existence of a superconducting state with Tc (up to 18 K) in thin films and...

  • Article
  • Open Access
4 Citations
3,656 Views
8 Pages

Measurements of an Effective Longitudinal Coherence Length in Transmission Small Angle X-ray Scatterings

  • Chun-Ting Liu,
  • Bo-Ching He,
  • Guo-Dung Chen,
  • Alice Chinghsuan Chang and ,
  • Wen-Li Wu and
  • Wei-En Fu
  • + 1 author+ 0 author

7 August 2020

The notion of an effective longitudinal coherence length with its value much greater than λ2/(2Δλ) has been adopted in small-angle X-ray scattering communities for years, where λ and Δλ denote the incident wave...

(This article belongs to the Section Synthesis, Interfaces and Nanostructures)
  • Article
  • Open Access
2 Citations
1,928 Views
14 Pages

Optimal Coherence Length Control in Interferometric Fiber Optic Hydrophones via PRBS Modulation: Theory and Experiment

  • Wujie Wang,
  • Qihao Hu,
  • Lina Ma,
  • Fan Shang and ,
  • Hongze Leng and
  • Junqiang Song
  • + 1 author+ 0 author

30 July 2025

Interferometric fiber optic hydrophones (IFOHs) are highly sensitive for underwater acoustic detection but face challenges owing to the trade-off between laser monochromaticity and coherence length. In this study, we propose a pseudo-random binary se...

(This article belongs to the Section Optical Sensors)
  • Article
  • Open Access
5 Citations
5,096 Views
8 Pages

26 July 2024

This study evaluates the inter-device measurement properties of partial coherence interferometry (PCI) and spectral domain optical coherence tomography (SD-OCT) in measuring axial length, particularly for myopia management. We recruited 82 eyes from...

  • Article
  • Open Access
2 Citations
6,244 Views
17 Pages

Superconducting stiffness ρs and coherence length ξ are usually determined by measuring the penetration depth λ of a magnetic field and the upper critical field Hc2 of a superconductor (SC), respectively. However, in magnetic SC, which...

(This article belongs to the Special Issue Selected Papers from the International Conference on Quantum Materials and Technologies (ICQMT2022))
  • Article
  • Open Access
1 Citations
1,730 Views
23 Pages

Powder X-ray diffraction (XRD) was used to determine the crystal structure of sodium chloride (NaCl) powder and to evaluate the accuracy with which a simple laboratory diffraction dataset can recover the crystallographic parameters of a well-known io...

  • Article
  • Open Access
5 Citations
4,286 Views
10 Pages

Evaluation of Bunch Length by Measuring Coherent Synchrotron Radiation with a Narrow-Band Detector at LEBRA

  • Takeshi Sakai,
  • Ken Hayakawa,
  • Toshinari Tanaka,
  • Yasushi Hayakawa and ,
  • Kyoko Nogami and
  • Norihiro Sei
  • + 1 author+ 0 author

This study presents a novel technology to measure electron bunch length with a high time resolution by measuring coherent synchrotron radiation using a narrow-band detector at Laboratory for Electron Beam Research and Application (LEBRA)—an S-b...

(This article belongs to the Special Issue THz: Research Frontiers for New Sources, Imaging and Other Advanced Technologies)
  • Article
  • Open Access
3 Citations
2,510 Views
18 Pages

2 December 2024

The problems of disorder and insufficient system length are generally regarded as central problems in the realization of Majorana zero modes (MZM), which are a promising platform for realizing fault-tolerant topological quantum computing (TQC). In th...

(This article belongs to the Section Quantum Materials)
  • Article
  • Open Access
1,784 Views
15 Pages

Designing a Femtosecond-Resolution Bunch Length Monitor Using Coherent Transition Radiation Images

  • Ana Guisao-Betancur,
  • Joseph Wolfenden,
  • Erik Mansten,
  • Sara Thorin and ,
  • Johan Lundquist,
  • Oliver Grimm and
  • Carsten P. Welsch
  • + 2 authors+ 0 author

Ultrashort bunch length measurements are crucial for characterizing electron beams in short-pulse accelerators, including novel accelerators like EuPRAXIA and those used for free-electron lasers (FELs). This work provides an overview of the design pr...

  • Article
  • Open Access
9 Citations
3,436 Views
11 Pages

A lower bound for the coherence block (ChB) length in mobile radio channels is derived in this paper. The ChB length, associated with a certain mobile radio channel, is of great practical importance in future wireless systems, mainly those based on m...

(This article belongs to the Special Issue Channel Characterization for Wireless and Mobile Communications)
  • Article
  • Open Access
438 Views
14 Pages

4 June 2026

Atmospheric turbulence originates from random fluctuations in the refractive index of the propagation medium that induce wavefront distortions and intensity scintillation. In application scenarios such as adaptive optics, rapid and accurate character...

  • Article
  • Open Access
223 Views
17 Pages

21 October 2026

Atmospheric turbulence is an important factor affecting the application of the free-space optical communication (FSOC) system in the atmospheric environment. The scintillation effect caused by turbulence distorts the phase and amplitude of the optica...

(This article belongs to the Section Optical Communication and Network)
  • Article
  • Open Access
2,644 Views
19 Pages

The conventional theory of neutron beams interacting with many-body systems treats the beam as a classical system, i.e., with its dynamical variables appearing in the quantum dynamics of the scattering process not as operators but only as c-numbers....

(This article belongs to the Special Issue Quantum Beam Science: Feature Papers 2023)
  • Article
  • Open Access
17 Citations
3,674 Views
19 Pages

Beam Properties of a Partially Coherent Beam Propagating Horizontally in Atmospheric Turbulence

  • Zengyan Wu,
  • Zhejun Feng,
  • Shubing Ye,
  • Baoming Song and ,
  • Runxi Wei and
  • Chaoran Yu
  • + 1 author+ 0 author

This study explored the impact of atmospheric turbulence on partially coherent light propagation. Atmospheric turbulence causes random modulation of the intensity and phase of light, resulting in a speckle pattern in the far field. This study focused...

(This article belongs to the Section Lasers, Light Sources and Sensors)
  • Article
  • Open Access
20 Citations
3,203 Views
12 Pages

By using the two-frequency coherence function model of a beam in a turbulent medium and the localized wave theory of the polychromatic beam, we develop the spectrum average mutual coherence function of the localized wave of Bessel–Gaussian ampl...

(This article belongs to the Special Issue Light Fields in the Ocean from Natural and Artificial Sources)
  • Article
  • Open Access
5,276 Views
12 Pages

31 December 2018

A magnetic chicane bunch compressor for a new compact accelerator-based terahertz (THz) radiation source at the Institute of Advanced Energy, Kyoto University, was completely installed in March 2016. The chicane is employed to compress an electron bu...

(This article belongs to the Special Issue Superradiances from Ultra Short Electron Bunch Beam)
  • Article
  • Open Access
2 Citations
2,695 Views
8 Pages

Clinical Evaluation of a New Spectral-Domain Optical Coherence Tomography-Based Biometer

  • Jorge L. Alió,
  • Marina José-Martínez,
  • Antonio Martínez-Abad,
  • Alejandra E. Rodríguez and ,
  • Francesco Versaci,
  • Jesper Hjortdal,
  • Joaquim Neto Murta,
  • Ana B. Plaza-Puche,
  • Mario Cantó-Cerdán and
  • David P. Piñero
  • + 5 authors+ 0 author

The VEMoS-AXL system is a new optical biometer based on spectral domain optical coherence tomography (SD-OCT) that has been tested in terms of intrasession repeatability and compared with a swept-source optical coherence tomography biometer (SS-OCT),...

(This article belongs to the Section Biomedical Optics)
  • Article
  • Open Access
4 Citations
2,114 Views
9 Pages

2 November 2021

In dental research, the morphometric assessment of restorations is a challenge. This also applies to the assessment of the length of interfacial adhesive defects in composite restorations as a measure of tooth-restoration bond failure. The determined...

(This article belongs to the Special Issue Medical Imaging: Advanced Techniques and Applications)
  • Article
  • Open Access
2 Citations
1,252 Views
12 Pages

Agreement in Biometric Parameters Between Swept-Source–Optical Coherence Tomography and Optical Low-Coherence Interferometry: Insights into Clinical Precision

  • Mihnea Munteanu,
  • Leila Al Barri,
  • Simona Stanca,
  • Valeria Mocanu and ,
  • Cosmin Rosca,
  • Nicolae-Constantin Balica and
  • Horia T. Stanca
  • + 2 authors+ 0 author

20 February 2025

Background/Objectives: Accurate biometric measurements are critical for achieving optimal refractive outcomes in cataract surgery. This study evaluated the agreement of biometric measurements between a swept-source optical coherence tomography (SS&nd...

(This article belongs to the Special Issue Corneal and Cataract Surgery: Clinical Updates)
  • Article
  • Open Access
6 Citations
2,424 Views
13 Pages

12 February 2025

Background/Objectives: Precise intraocular lens (IOL) power calculations are essential for achieving optimal refractive outcomes in cataract surgery. This study compares the predictive accuracy of swept-source optical coherence tomography (SS-OCT) an...

(This article belongs to the Special Issue Cataract and Refractive Surgery, and Intraocular Lens (IOL) Implantation: Recent Advances and Perspectives)
  • Article
  • Open Access
17 Citations
6,907 Views
17 Pages

16 April 2021

The records of seismic noise in Japan for the period of 1997–2020, which includes the Tohoku seismic catastrophe on 11 March 2011, are considered. The following properties of noise are analyzed: The wavelet-based Donoho–Johnston index, the singularit...

(This article belongs to the Special Issue Complex Systems Time Series Analysis and Modeling for Geoscience)
  • Article
  • Open Access
8 Citations
14,451 Views
11 Pages

6 May 2008

The spatial resolution of a conventional imaging lidar system is constrained by the diffraction limit of the telescope’s aperture. The combination of the lidar and synthetic aperture (SA) processing techniques may overcome the diffraction limit and p...

(This article belongs to the Special Issue Synthetic Aperture Radar (SAR))
  • Article
  • Open Access
2 Citations
4,165 Views
13 Pages

Electrical and Thermal Transport Properties of Layered Superconducting Ca10(Pt4As8)((Fe0.86Pt0.14)2As2)5 Single Crystal

  • Dapeng Wu,
  • Xiaodong Meng,
  • Yingying Zhai,
  • Huaming Yu and ,
  • Jiao Yu and
  • Yang Qi
  • + 1 author+ 0 author

4 February 2019

We have synthesized single crystals of iron-based superconducting Ca10(Pt4As8)((Fe0.86Pt0.14)2As2)5 and performed extensive measurements on their transport properties. A remarkable difference in the behavior and a large anisotropy between in-plane an...

  • Article
  • Open Access
225 Views
19 Pages

Metric-Specific Ocular Magnification Artifacts in Quantitative OCT Angiography: A Controlled Image-Based Simulation Study

  • Marija Veselinović,
  • Marija Trenkić,
  • Jelena Vasiljević,
  • Enisa Memić and ,
  • Biljana Trajković and
  • Aida Kasumović Bećirović
  • + 1 author+ 0 author

24 October 2026

Background and Objectives: Optical coherence tomography angiography (OCTA) devices convert scan angle into retinal distance with a schematic eye, so eyes whose axial length (AL) differs from the assumed value are measured on an incorrect transverse s...

(This article belongs to the Special Issue Ophthalmology: New Diagnostic and Treatment Approaches (3rd Edition))
  • Article
  • Open Access
7 Citations
3,080 Views
13 Pages

Ultra-wide-field optical coherence tomography (UWF-OCT) has been recently introduced into clinical ophthalmological practice. To date, there are few data on the reference values of the retinal thickness (RT) and choroidal thickness (CT) measured with...

(This article belongs to the Special Issue State of the Art in Retinal Optical Coherence Tomography Images)
  • Article
  • Open Access
2 Citations
4,274 Views
8 Pages

Metallic Conduction and Carrier Localization in Two-Dimensional BEDO-TTF Charge-Transfer Solid Crystals

  • Hiroshi Ito,
  • Motoki Matsuno,
  • Seiu Katagiri,
  • Shinji K. Yoshina and ,
  • Taishi Takenobu,
  • Manabu Ishikawa,
  • Akihiro Otsuka,
  • Hideki Yamochi,
  • Yukihiro Yoshida and
  • Masahiro Yamashita
  • + 7 authors+ 2 authors

24 December 2021

Charge-transfer salts based on bis(ethylenedioxy)tetrathiafulvalene (BEDO-TTF or BO for short) provide a stable two-dimensional (2D) metallic state, while the electrical resistance often shows an upturn at low temperatures below ~10 K. Such 2D weak c...

(This article belongs to the Special Issue New Spin on Metal-Insulator Transitions)
  • Communication
  • Open Access
2 Citations
4,581 Views
13 Pages

A Computational Model of Cn2 Profile Inversion for Atmospheric Laser Communication in the Vertical Path

  • Haifeng Yao,
  • Yuxi Cao,
  • Weihao Wang,
  • Qingfang Jiang and ,
  • Jie Cao,
  • Qun Hao,
  • Zhi Liu,
  • Peng Zhang,
  • Yidi Chang and
  • Tongtong Geng
  • + 6 authors+ 1 author

25 June 2023

In this paper, an atmospheric structure constant Cn2 model is proposed for evaluating the channel turbulence degree of atmospheric laser communication. First, we derive a mathematical model for the correlation between the atmospheric coherence length...

(This article belongs to the Special Issue Advanced Infocomm Technology including Selected Papers from 14th ICAIT 2022)
  • Feature Paper
  • Article
  • Open Access
7 Citations
3,657 Views
18 Pages

17 June 2022

Long waves caused by storm surges or river floods can significantly impact marine and fluvial structures such as bridge piers. Apart from the forces that they generate on the structure, they also contribute to the formation of turbulent eddies downst...

(This article belongs to the Special Issue Flow Hydrodynamic in Open Channels: Interaction with Natural or Man-Made Structures)
  • Article
  • Open Access
25 Citations
3,177 Views
12 Pages

Globotrioasylsphingosine Levels and Optical Coherence Tomography Angiography in Fabry Disease Patients

  • Maximilian Robert Justus Wiest,
  • Mario Damiano Toro,
  • Albina Nowak,
  • Joel Baur and ,
  • Katrin Fasler,
  • Timothy Hamann,
  • Mayss Al-Sheikh and
  • Sandrine Anne Zweifel
  • + 3 authors+ 0 author

5 March 2021

Background: To date, there are no studies associating the dried blood spot (DBS) levels of globotrioasylsphingosine (lysoGb3) with quantitative optical coherence tomography angiography (OCTA) parameters in Fabry disease (FD) patients. Here, we aimed...

(This article belongs to the Collection The Eye in Systemic Diseases)
  • Communication
  • Open Access
1 Citations
3,120 Views
11 Pages

The Depairing Current Density of a Fe(Se,Te) Crystal Evaluated in Presence of Demagnetizing Factors

  • Armando Galluzzi,
  • Krastyo Buchkov,
  • Vihren Tomov,
  • Elena Nazarova and ,
  • Antonio Leo,
  • Gaia Grimaldi,
  • Adrian Crisan and
  • Massimiliano Polichetti
  • + 3 authors+ 0 author

The effect of the demagnetizing factor, regarding the determination of the de-pairing current density Jdep, has been studied in the case of a Fe(Se,Te) crystal, using DC magnetic measurements as a function of a magnetic field (H) at different tempera...

(This article belongs to the Special Issue Selected Papers from the 8th International Conference on Superconductivity and Magnetism (ICSM2023))
  • Article
  • Open Access
4 Citations
2,965 Views
9 Pages

Effect of Segmented Optical Axial Length on the Performance of New-Generation Intraocular Lens Power Calculation Formulas in Extremely Long Eyes

  • So Goto,
  • Naoyuki Maeda,
  • Kota Uehara,
  • Keiko Ogawa and ,
  • Maki Matsumaru,
  • Saori Sugiyama,
  • Kazuhiko Ohnuma,
  • Tjundewo Lawu and
  • Toru Noda
  • + 4 authors+ 0 author

7 November 2023

Purpose: To evaluate the performance of traditional vergence formulas with segmented axial length (AL) compared to traditional composite AL in extremely long eyes, and to determine whether the segmented AL can be extended to the new-generation formul...

(This article belongs to the Special Issue Ophthalmic Optics and Visual Function—Part II)
  • Article
  • Open Access
3 Citations
1,563 Views
9 Pages

12 September 2025

Neutron–antineutron oscillation (nnbar-osc) is a baryon number-violating process and a sensitive probe for physics beyond the standard model. Ultra-cold neutrons (UCNs) are attractive for nnbar-osc searches because of their long storage time, b...

(This article belongs to the Section C: Physics)
  • Article
  • Open Access
2,431 Views
17 Pages

10 July 2025

Background/Objectives: Myopia is associated with peripapillary changes, namely, gamma peripapillary atrophy (γPPA) and optic disc ovalization, estimated by the ovality index (OI). These changes have been suggested to be promoted by adduction. R...

(This article belongs to the Section Ophthalmology)
  • Article
  • Open Access
7 Citations
10,220 Views
13 Pages

Non-Hospitalized Long COVID Patients Exhibit Reduced Retinal Capillary Perfusion: A Prospective Cohort Study

  • Clayton E. Lyons,
  • Jonathan Alhalel,
  • Anna Busza,
  • Emily Suen and ,
  • Nathan Gill,
  • Nicole Decker,
  • Stephen Suchy,
  • Zachary Orban,
  • Millenia Jimenez and
  • Manjot K. Gill
  • + 7 authors+ 2 authors

17 February 2025

The mechanism of post-acute sequelae of SARS-CoV-2 (PASC) is unknown. Using optical coherence tomography angiography (OCT-A), we compared retinal foveal avascular zone (FAZ), vessel density (VD), and vessel length density (VLD) in non-hospitalized Ne...

(This article belongs to the Section Medical Imaging)
  • Article
  • Open Access
1 Citations
2,286 Views
11 Pages

Relationship of Vessel Density to Vessel Length Density in Patients with Treated Fabry Disease

  • Maximilian Robert Justus Wiest,
  • Mario Damiano Toro,
  • Albina Nowak,
  • Anahita Bajka and ,
  • Katrin Fasler,
  • Mayss Al-Sheikh,
  • Timothy Hamann and
  • Sandrine Anne Zweifel
  • + 3 authors+ 0 author

Background: Fabry disease (FD) is a potentially lethal lysosomal disorder with systemic vascular changes. Previous studies demonstrated retinal vascular involvement using optical coherence tomography angiography (OCTA) in affected patients; Aim: To a...

(This article belongs to the Special Issue Optical Coherence Tomography Angiography (OCTA) as a New Diagnostic Tool in Ocular and Systemic Diseases—2nd Edition)
  • Article
  • Open Access
13 Citations
3,840 Views
10 Pages

Comparison Study of the Two Biometers Based on Swept-Source Optical Coherence Tomography Technology

  • Jing Dong,
  • Jinhan Yao,
  • Shuimiao Chang,
  • Piotr Kanclerz and ,
  • Ramin Khoramnia and
  • Xiaogang Wang
  • + 1 author+ 0 author

26 February 2022

This research aimed to investigate the potential differences in the parameters, including axial length (AL), central corneal thickness (CCT), anterior chamber depth (ACD), lens thickness (LT), flat keratometry (Kf), steep keratometry (Ks), mean kerat...

(This article belongs to the Section Pathology and Molecular Diagnostics)
  • Article
  • Open Access
1 Citations
2,885 Views
20 Pages

29 February 2020

A method of reference-free speckle spectroscopy based on the statistical analysis of intensity spatial fluctuations of the spectrally-selected multiple-scattered fluorescence radiation is examined in the case of the finite-band spectral selection of...

(This article belongs to the Special Issue Laser Spectroscopy)
  • Article
  • Open Access
116 Views
13 Pages

6 November 2026

Background/Objectives: Although commercially available spectral-domain optical coherence tomography (SD-OCT) platforms are primarily designed for retinal and anterior segment imaging, ocular biometry can be enabled through additional software. This s...

(This article belongs to the Special Issue Clinical Advancements in Intraocular Lens Power Calculation Methods)
  • Article
  • Open Access
1,260 Views
24 Pages

Sector-Specific Patterns of RNFL and Ganglion Cell Complex Thinning Across the Myopia Spectrum: A Cross-Sectional OCTA Study

  • Marija Veselinović,
  • Marija Trenkić,
  • Sonja Cekić,
  • Jasmina Jocić Djordjević and
  • Aleksandar Veselinović

31 May 2026

Background and Objectives: Myopia is a rapidly growing global health burden driven primarily by axial elongation, which exerts mechanical stress on the inner retina, leading to progressive thinning of the retinal nerve fiber layer (RNFL) and the gang...

(This article belongs to the Section Ophthalmology)
  • Article
  • Open Access
429 Views
13 Pages

30 June 2026

Background/Objectives: To evaluate subclinical structural and functional retinal alterations in clinically normal myopic eyes using optical coherence tomography (OCT) and automated visual field analysis. Methods: This retrospective observational stud...

(This article belongs to the Section Ophthalmology)
  • Article
  • Open Access
3 Citations
3,514 Views
13 Pages

25 April 2022

Optical coherence tomography (OCT) has a wide range of uses in bioimaging and nondestructive testing. Larger bandwidth light sources have recently been implemented to enhance measurement resolution. Increased bandwidth has a negative impact on spectr...

(This article belongs to the Section Optical Sensors)
  • Article
  • Open Access
6 Citations
4,511 Views
19 Pages

Digital Holography as Computer Vision Position Sensor with an Extended Range of Working Distances

  • Miguel Asmad Vergara,
  • Maxime Jacquot,
  • Guillaume J. Laurent and
  • Patrick Sandoz

22 June 2018

Standard computer vision methods are usually based on powerful contact-less measurement approaches but applications, especially at the micro-scale, are restricted by finite depth-of-field and fixed working distance of imaging devices. Digital hologra...

(This article belongs to the Section Physical Sensors)
  • Article
  • Open Access
2 Citations
3,633 Views
16 Pages

10 January 2022

Spectra of coherent edge radiation (CER) were observed at the S-band linac facility of Kyoto University Free Electron Laser. A local maximum was observed in the CER spectrum on-crest operation of the radio frequency (RF) field. As the phase of the RF...

(This article belongs to the Section Optics and Lasers)
  • Article
  • Open Access
575 Views
9 Pages

Impact of Axial Length on Visual Outcomes and OCT Findings in Epiretinal Membrane: A Retrospective Study

  • Reo Sueno,
  • Noriko Kubota,
  • Yosai Mori,
  • Kazunori Miyata and ,
  • Yuji Nakano,
  • Hitoshi Goto,
  • Tomoyuki Kunishige and
  • Fumiki Okamoto
  • + 3 authors+ 0 author

4 June 2026

Background: Axial elongation may influence the structural characteristics and surgical prognosis of epiretinal membrane (ERM), but its impact across different axial length (AL) categories remains unclear. Methods: We retrospectively analyzed 557 eyes...

(This article belongs to the Section Ophthalmology)
  • Article
  • Open Access
2,475 Views
10 Pages

Comparing the Accuracy of Four Intraocular Lens Formulas in Eyes with Two Types of Widely Used Monofocal Lens Implants

  • Monica Malaescu,
  • Bogdana Tabacaru,
  • Mihnea Munteanu,
  • Leila Al Barri and ,
  • Adriana Stanila and
  • Horia Tudor Stanca
  • + 1 author+ 0 author

11 August 2022

The present study aimed to compare the accuracy of intraocular lens calculation formulas Barrett Universal II, Hoffer Q, Holladay 1, and SRK/T in the prediction of postoperative refraction for two widely used monofocal implants: SN60WF and ZCB00. All...

(This article belongs to the Section Biophotonics and Biomedical Optics)

of 14