Skip to Content

208 Results Found

  • Article
  • Open Access
26 Citations
7,143 Views
11 Pages

Reduction in the Motion Artifacts in Noncontact ECG Measurements Using a Novel Designed Electrode Structure

  • Jianwen Ding,
  • Yue Tang,
  • Ronghui Chang,
  • Yu Li and ,
  • Limin Zhang and
  • Feng Yan
  • + 1 author+ 0 author

14 January 2023

A noncontact ECG is applicable to wearable bioelectricity acquisition because it can provide more comfort to the patient for long-term monitoring. However, the motion artifact is a significant source of noise in an ECG recording. Adaptive noise reduc...

(This article belongs to the Topic Advances in Intelligent Biosignals Processing and Analysis)
  • Article
  • Open Access
18 Citations
6,422 Views
24 Pages

1 October 2023

The goal of this study was to test a novel approach (iCanClean) to remove non-brain sources from scalp EEG data recorded in mobile conditions. We created an electrically conductive phantom head with 10 brain sources, 10 contaminating sources, scalp,...

(This article belongs to the Special Issue Sensors in Neuroimaging and Neurorehabilitation)
  • Article
  • Open Access
17 Citations
4,376 Views
15 Pages

Using the Redundant Convolutional Encoder–Decoder to Denoise QRS Complexes in ECG Signals Recorded with an Armband Wearable Device

  • Natasa Reljin,
  • Jesus Lazaro,
  • Md Billal Hossain,
  • Yeon Sik Noh and ,
  • Chae Ho Cho and
  • Ki H. Chon
  • + 1 author+ 0 author

17 August 2020

Long-term electrocardiogram (ECG) recordings while performing normal daily routines are often corrupted with motion artifacts, which in turn, can result in the incorrect calculation of heart rates. Heart rates are important clinical information, as t...

(This article belongs to the Special Issue Recent Advances in ECG Monitoring)
  • Article
  • Open Access
208 Views
14 Pages

Ambulatory Holter electrocardiogram (ECG) monitoring is increasingly used in ambulatory elderly populations; however, age-related physiological and mechanical factors substantially increase susceptibility to motion-induced signal artifacts, limiting...

  • Article
  • Open Access
1 Citations
2,868 Views
11 Pages

12 August 2024

Background and Objectives: This study’s objective was to investigate the influence of increased scan speed and pitch on image quality and nodule volumetry in patients who underwent ultra-low-dose chest computed tomography (CT). Material and Met...

(This article belongs to the Section Pulmonology)
  • Article
  • Open Access
37 Citations
9,563 Views
14 Pages

28 July 2019

With photoplethysmograph (PPG) sensors showing increasing potential in wearable health monitoring, the challenging problem of motion artifact (MA) removal during intensive exercise has become a popular research topic. In this study, a novel method th...

(This article belongs to the Section Biosensors)
  • Article
  • Open Access
7 Citations
5,252 Views
21 Pages

A Novel Signal Restoration Method of Noisy Photoplethysmograms for Uninterrupted Health Monitoring

  • Aikaterini Vraka,
  • Roberto Zangróniz,
  • Aurelio Quesada,
  • Fernando Hornero and ,
  • Raúl Alcaraz and
  • José J. Rieta
  • + 1 author+ 0 author

26 December 2023

Health-tracking from photoplethysmography (PPG) signals is significantly hindered by motion artifacts (MAs). Although many algorithms exist to detect MAs, the corrupted signal often remains unexploited. This work introduces a novel method able to rec...

(This article belongs to the Special Issue Biosignal Sensing and Processing for Clinical Diagnosis II)
  • Article
  • Open Access
930 Views
25 Pages

1 June 2026

This paper proposes a two-stage hybrid framework for biosignal quality validation that produces beat-level or segment-level labels for real-time filtering and offline dataset curation. The framework is quantitatively validated exclusively on ECG data...

(This article belongs to the Section Biosensors)
  • Article
  • Open Access
2 Citations
1,369 Views
32 Pages

9 December 2025

Movement artifact direction and magnitude are critical parameters in noise detection and image analysis, especially for single-frame images where temporal information is unavailable. This paper introduces the Movement Artifact Direction Estimation (M...

(This article belongs to the Special Issue Innovative Sensing Methods for Motion and Behavior Analysis)
  • Review
  • Open Access
26 Citations
9,428 Views
22 Pages

7 January 2021

The development of biosensors that measure various biosignals from our body is an indispensable research field for health monitoring. In recent years, as the demand to monitor the health conditions of individuals in real time have increased, wearable...

(This article belongs to the Special Issue 3D-Bioprinted Organs-on-Chips for Clinical Application)
  • Article
  • Open Access
97 Citations
12,264 Views
13 Pages

Effects of Cable Sway, Electrode Surface Area, and Electrode Mass on Electroencephalography Signal Quality during Motion

  • Evangelia-Regkina Symeonidou,
  • Andrew D. Nordin,
  • W. David Hairston and
  • Daniel P. Ferris

3 April 2018

More neuroscience researchers are using scalp electroencephalography (EEG) to measure electrocortical dynamics during human locomotion and other types of movement. Motion artifacts corrupt the EEG and mask underlying neural signals of interest. The c...

(This article belongs to the Special Issue Novel Sensors for Bioimaging)
  • Article
  • Open Access
13 Citations
6,122 Views
16 Pages

29 June 2018

Electrocardiograms (ECGs) can be conveniently obtained using capacitive ECG sensors. However, motion noise in measured ECGs can degrade R peak detection. To reduce noise, properties of reference signal and ECG measured by the sensors are analyzed and...

(This article belongs to the Special Issue Sensors for Biosignal Processing)
  • Article
  • Open Access
879 Views
28 Pages

1 June 2026

Remote Photoplethysmography (rPPG) provides a non-contact alternative to traditional heart rate monitoring. Estimating physiological signals from facial videos has recently attracted significant research interest. However, rPPG performance is sensiti...

(This article belongs to the Section Biomedical Sensors)
  • Article
  • Open Access
3 Citations
6,083 Views
14 Pages

14 January 2025

Generally, the electrocardiography (ECG) system plays an important role in preventing and diagnosing heart diseases. To further improve the amenity and convenience of using an ECG system, we built a customized capacitive electrocardiography (cECG) sy...

(This article belongs to the Section Biomedical Sensors)
  • Article
  • Open Access
18 Citations
6,066 Views
24 Pages

Preeminently Robust Neural PPG Denoiser

  • Ju Hyeok Kwon,
  • So Eui Kim,
  • Na Hye Kim,
  • Eui Chul Lee and
  • Jee Hang Lee

8 March 2022

Photoplethysmography (PPG) is a simple and cost-efficient technique that effectively measures cardiovascular response by detecting blood volume changes in a noninvasive manner. A practical challenge in the use of PPGs in real-world applications is no...

(This article belongs to the Special Issue Machine Learning for Biomedical Sensing and Healthcare)
  • Article
  • Open Access
46 Citations
8,556 Views
14 Pages

Adaptive Motion Artifact Reduction in Wearable ECG Measurements Using Impedance Pneumography Signal

  • Xiang An,
  • Yanzhong Liu,
  • Yixin Zhao,
  • Sichao Lu and ,
  • George K. Stylios and
  • Qiang Liu
  • + 1 author+ 0 author

23 July 2022

Noise is a common problem in wearable electrocardiogram (ECG) monitoring systems because the presence of noise can corrupt the ECG waveform causing inaccurate signal interpretation. By comparison with electromagnetic interference and its minimization...

(This article belongs to the Special Issue Advanced Wearable Sensors Technologies for Healthcare Monitoring)
  • Article
  • Open Access
15 Citations
5,007 Views
22 Pages

Deep Learning for Motion Artifact-Suppressed OCTA Image Generation from Both Repeated and Adjacent OCT Scans

  • Zhefan Lin,
  • Qinqin Zhang,
  • Gongpu Lan,
  • Jingjiang Xu and ,
  • Jia Qin,
  • Lin An and
  • Yanping Huang
  • + 2 authors+ 0 author

30 January 2024

Optical coherence tomography angiography (OCTA) is a popular technique for imaging microvascular networks, but OCTA image quality is commonly affected by motion artifacts. Deep learning (DL) has been used to generate OCTA images from structural OCT i...

(This article belongs to the Special Issue Applications of Artificial Intelligence in Biomedical Image Processing)
  • Article
  • Open Access
760 Views
44 Pages

7 June 2026

Capacitive electrocardiography (cECG) enables non-contact heart rate monitoring through clothing, but motion artifacts remain a critical limitation for practical applications. We present a novel motion artifact removal method using non-contact floati...

(This article belongs to the Special Issue Wearable, Non-Contact and Capacitive Sensing for Biomedical and Industrial Applications)
  • Article
  • Open Access
32 Citations
9,110 Views
18 Pages

The Effects of Motion Artifacts on Self-Avatar Agency

  • Alexandros Koilias,
  • Christos Mousas and
  • Christos-Nikolaos Anagnostopoulos

One way of achieving self-agency in virtual environments is by using a motion capture system and retargeting user’s motion to the virtual avatar. In this study, we investigated whether the self-agency is affected when motion artifacts appear on top o...

  • Article
  • Open Access
65 Citations
8,166 Views
14 Pages

1 July 2019

Electrocardiogram (ECG) signals are crucial for determining the health status of the human heart. A clean ECG signal is critical in analysis and diagnosis of heart diseases. However, ECG signals are often contaminated by motion artifact noise in the...

(This article belongs to the Special Issue Signal Processing for Intelligent Sensor Systems)
  • Article
  • Open Access
3 Citations
3,197 Views
16 Pages

Correction of Arterial-Phase Motion Artifacts in Gadoxetic Acid-Enhanced Liver MRI Using an Innovative Unsupervised Network

  • Feng Pan,
  • Qianqian Fan,
  • Han Xie,
  • Chongxin Bai and ,
  • Zhi Zhang,
  • Hebing Chen,
  • Lian Yang,
  • Xin Zhou,
  • Qingjia Bao and
  • Chaoyang Liu
  • + 5 authors+ 0 author

This study aims to propose and evaluate DR-CycleGAN, a disentangled unsupervised network by introducing a novel content-consistency loss, for removing arterial-phase motion artifacts in gadoxetic acid-enhanced liver MRI examinations. From June 2020 t...

(This article belongs to the Special Issue Artificial Intelligence-Based Diagnostics and Biomedical Analytics)
  • Article
  • Open Access
25 Citations
5,556 Views
16 Pages

5 September 2018

In this paper, a new motion artifact correction method is proposed based on multi-channel functional near-infrared spectroscopy (fNIRS) signals. Recently, wavelet transform and hemodynamic response function-based algorithms were proposed as methods o...

(This article belongs to the Section Sensor Networks)
  • Article
  • Open Access
20 Citations
5,299 Views
17 Pages

Electrode Humidification Design for Artifact Reduction in Capacitive ECG Measurements

  • Yue Tang,
  • Ronghui Chang,
  • Limin Zhang,
  • Feng Yan and ,
  • Haowen Ma and
  • Xiaofeng Bu
  • + 1 author+ 0 author

18 June 2020

For wearable capacitive electrocardiogram (ECG) acquisition, capacitive electrodes may cause severe motion artifacts due to the relatively large friction between the electrodes and the dielectrics. In some studies, water can effectively suppress moti...

(This article belongs to the Special Issue ECG Monitoring System)
  • Article
  • Open Access
22 Citations
6,021 Views
14 Pages

The Impact of AI on Metal Artifacts in CBCT Oral Cavity Imaging

  • Róża Wajer,
  • Adrian Wajer,
  • Natalia Kazimierczak,
  • Justyna Wilamowska and
  • Zbigniew Serafin

Objective: This study aimed to assess the impact of artificial intelligence (AI)-driven noise reduction algorithms on metal artifacts and image quality parameters in cone-beam computed tomography (CBCT) images of the oral cavity. Materials and Method...

(This article belongs to the Special Issue Advances in Oral and Maxillofacial Radiology)
  • Article
  • Open Access
21 Citations
6,452 Views
18 Pages

2 April 2018

The aim of this study is on the investigation of motion noise removal techniques using two-accelerometer sensor system and various placements of the sensors on gentle movement and walking of the patients. A Wi-Fi based data acquisition system and a f...

(This article belongs to the Section Biosensors)
  • Article
  • Open Access
16 Citations
4,502 Views
17 Pages

30 December 2020

Driver-centered infotainment and telematics services are provided for intelligent vehicles that improve driver convenience. Driver-centered services are performed after identification, and a biometrics system using bio-signals is applied. The electro...

(This article belongs to the Special Issue Computational Intelligence and Intelligent Contents (CIIC))
  • Study Protocol
  • Open Access
5 Citations
3,871 Views
9 Pages

Investigating the Influence of High-Speed Gantry Rotation in Cardiac CT on Motion Artifacts in Aortic Stenosis Patients Not Premedicated with β-Blockers: The FAST-CCT Randomized Trial Protocol

  • Guillaume Fahrni,
  • Giuseppe Gullo,
  • Aisha Touray,
  • Stéphane Fournier and ,
  • Anne-Marie Jouannic,
  • Henri Lu,
  • Damien Racine,
  • Olivier Muller,
  • Chiara Pozzessere and
  • David C. Rotzinger
  • + 6 authors+ 1 author

Background: Coronary CT angiography (CCTA) is increasingly used as a non-invasive tool to assess coronary artery disease (CAD). However, CCTA is subject to motion artifacts, potentially limiting its clinical utility. Despite faster (0.35 and 0.28 s/r...

(This article belongs to the Special Issue Clinical Applications of Cardiovascular Computed Tomography (CT))
  • Article
  • Open Access
14 Citations
6,385 Views
14 Pages

This study aimed to remove motion artifacts from brain magnetic resonance (MR) images using a U-Net model. In addition, a simulation method was proposed to increase the size of the dataset required to train the U-Net model while avoiding the overfitt...

(This article belongs to the Special Issue Computer Vision and Machine Learning in Medical Applications)
  • Article
  • Open Access
7 Citations
4,274 Views
21 Pages

A Comparison of Approaches for Motion Artifact Removal from Wireless Mobile EEG During Overground Running

  • Patrick S. Ledwidge,
  • Carly N. McPherson,
  • Lily Faulkenberg,
  • Alexander Morgan and
  • Gordon C. Baylis

5 August 2025

Electroencephalography (EEG) is the only brain imaging method light enough and with the temporal precision to assess electrocortical dynamics during human locomotion. However, head motion during whole-body movements produces artifacts that contaminat...

(This article belongs to the Special Issue EEG Signal Processing in Healthcare, Cognitive Neuroscience, and Medical Diagnosis)
  • Article
  • Open Access
23 Citations
5,125 Views
16 Pages

24 July 2019

Heart rate has been measured comfortably using a camera without the skin-contact by the development of vision-based measurement. Despite the potential of the vision-based measurement, it has still presented limited ability due to the noise of illumin...

(This article belongs to the Section Biosensors)
  • Article
  • Open Access
79 Citations
31,841 Views
12 Pages

Noisy ECG Signal Analysis for Automatic Peak Detection

  • Matteo D’Aloia,
  • Annalisa Longo and
  • Maria Rizzi

22 January 2019

Cardiac signal processing is usually a computationally demanding task as signals are heavily contaminated by noise and other artifacts. In this paper, an effective approach for peak point detection and localization in noisy electrocardiogram (ECG) si...

(This article belongs to the Special Issue eHealth and Artificial Intelligence)
  • Article
  • Open Access
17 Citations
12,382 Views
15 Pages

5 July 2023

A new method for accurately estimating heart rates based on a single photoplethysmography (PPG) signal and accelerations is proposed in this study, considering motion artifacts due to subjects’ hand motions and walking. The method comprises two...

(This article belongs to the Special Issue Advanced Sensors for Real-Time Monitoring Applications ‖)
  • Article
  • Open Access
17 Citations
7,013 Views
27 Pages

Fully-Gated Denoising Auto-Encoder for Artifact Reduction in ECG Signals

  • Ahmed Shaheen,
  • Liang Ye,
  • Chrishni Karunaratne and
  • Tapio Seppänen

29 January 2025

Cardiovascular diseases (CVDs) are the primary cause of death worldwide. For accurate diagnosis of CVDs, robust and efficient ECG denoising is particularly critical in ambulatory cases where various artifacts can degrade the quality of the ECG signal...

(This article belongs to the Section Electronic Sensors)
  • Article
  • Open Access
1 Citations
2,442 Views
34 Pages

Impact of Simulated Artifacts on the Classification Performance of Apical Views in Transthoracic Echocardiography Using Convolutional Neural Networks

  • Gabriela Bernadeta Orzeł-Łomozik,
  • Łukasz Łomozik,
  • Maciej Podolski,
  • Martyna Rożek and ,
  • Kalina Światlak,
  • Weronika Radwan,
  • Zuzanna Przybylska,
  • Paulina Michalska,
  • Maciej Pruski and
  • Katarzyna Mizia-Stec
  • + 5 authors+ 0 author

Background: In recent years, artificial intelligence (AI) methods, including deep convolutional neural networks (CNNs), have gained increasing importance in supporting the automated analysis of echocardiograms. The aim of this study was to evaluate t...

(This article belongs to the Special Issue Machine Learning in Biomedical Research: Application, Innovation and Exploration)
  • Article
  • Open Access
4 Citations
2,404 Views
14 Pages

Enhancing Cone-Beam CT Image Quality in TIPSS Procedures Using AI Denoising

  • Reza Dehdab,
  • Andreas S. Brendlin,
  • Gerd Grözinger,
  • Haidara Almansour and ,
  • Jan Michael Brendel,
  • Sebastian Gassenmaier,
  • Patrick Ghibes,
  • Sebastian Werner,
  • Konstantin Nikolaou and
  • Saif Afat
  • + 5 authors+ 0 author

9 September 2024

Purpose: This study evaluates a deep learning-based denoising algorithm to improve the trade-off between radiation dose, image noise, and motion artifacts in TIPSS procedures, aiming for shorter acquisition times and reduced radiation with maintained...

(This article belongs to the Section Machine Learning and Artificial Intelligence in Diagnostics)
  • Article
  • Open Access
23 Citations
7,007 Views
24 Pages

Motion Artifacts Correction from Single-Channel EEG and fNIRS Signals Using Novel Wavelet Packet Decomposition in Combination with Canonical Correlation Analysis

  • Md Shafayet Hossain,
  • Muhammad E. H. Chowdhury,
  • Mamun Bin Ibne Reaz,
  • Sawal Hamid Md Ali and ,
  • Ahmad Ashrif A. Bakar,
  • Serkan Kiranyaz,
  • Amith Khandakar,
  • Mohammed Alhatou,
  • Rumana Habib and
  • Muhammad Maqsud Hossain
  • + 5 authors+ 0 author

21 April 2022

The electroencephalogram (EEG) and functional near-infrared spectroscopy (fNIRS) signals, highly non-stationary in nature, greatly suffers from motion artifacts while recorded using wearable sensors. Since successful detection of various neurological...

(This article belongs to the Special Issue EEG Signal Processing for Biomedical Applications)
  • Article
  • Open Access
1 Citations
841 Views
17 Pages

Dynamic myocardial CT perfusion imaging enables functional assessment of coronary artery stenosis and myocardial microvascular disease. However, it is susceptible to residual motion artifacts arising from cardiac and respiratory activity. These artif...

(This article belongs to the Special Issue Recent Advances and Applications of Machine Learning in Pattern Recognition)
  • Article
  • Open Access
19 Citations
5,859 Views
12 Pages

12 October 2021

Remote sensing of vital signs has been developed to improve the measurement environment by using a camera without a skin-contact sensor. The camera-based method is based on two concepts, namely color and motion. The color-based method, remote photopl...

(This article belongs to the Special Issue Advanced Signal Processing in Wearable Sensors for Health Monitoring)
  • Article
  • Open Access
1 Citations
1,230 Views
20 Pages

High-Speed Image Restoration Based on a Dynamic Vision Sensor

  • Paul K. J. Park,
  • Junseok Kim,
  • Juhyun Ko and
  • Yeoungjin Chang

23 January 2026

We report on the post-capture, on-demand deblurring technique based on a Dynamic Vision Sensor (DVS). Motion blur causes photographic defects inherently in most use cases of mobile cameras. To compensate for motion blur in mobile photography, we use...

(This article belongs to the Special Issue Advances in Optical Sensing, Instrumentation and Systems: 2nd Edition)
  • Article
  • Open Access
11 Citations
3,715 Views
15 Pages

Windowed Eigen-Decomposition Algorithm for Motion Artifact Reduction in Optical Coherence Tomography-Based Angiography

  • Tianyu Zhang,
  • Kanheng Zhou,
  • Holly R. Rocliffe,
  • Antonella Pellicoro and ,
  • Jenna L. Cash,
  • Wendy Wang,
  • Zhiqiong Wang,
  • Chunhui Li and
  • Zhihong Huang
  • + 4 authors+ 0 author

28 December 2022

Optical coherence tomography-based angiography (OCTA) has attracted attention in clinical applications as a non-invasive and high-resolution imaging modality. Motion artifacts are the most seen artifact in OCTA. Eigen-decomposition (ED) algorithms ar...

  • Proceeding Paper
  • Open Access
8 Citations
5,309 Views
14 Pages

27 January 2022

It is very challenging to estimate the accurate heart rate/beat during intense physical activities due to corruption of motion artifacts (MAs). However, it is difficult to reconstruct a clean signal and extract heart rate/beat from contaminated photo...

(This article belongs to the Proceedings of The 8th International Electronic Conference on Sensors and Applications)
  • Article
  • Open Access
2 Citations
1,400 Views
18 Pages

Simulation Data-Based Dual Domain Network (Sim-DDNet) for Motion Artifact Reduction in MR Images

  • Seong-Hyeon Kang,
  • Jun-Young Chung,
  • Youngjin Lee and
  • for The Alzheimer’s Disease Neuroimaging Initiative

Brain magnetic resonance imaging (MRI) is highly susceptible to motion artifacts that degrade fine structural details and undermine quantitative analysis. Conventional U-Net-based deep learning approaches for motion artifact reduction typically opera...

  • Article
  • Open Access
8 Citations
4,064 Views
20 Pages

The MotoNet: A 3 Tesla MRI-Conditional EEG Net with Embedded Motion Sensors

  • Joshua Levitt,
  • André van der Kouwe,
  • Hongbae Jeong,
  • Laura D. Lewis and
  • Giorgio Bonmassar

28 March 2023

We introduce a new electroencephalogram (EEG) net, which will allow clinicians to monitor EEG while tracking head motion. Motion during MRI limits patient scans, especially of children with epilepsy. EEG is also severely affected by motion-induced no...

(This article belongs to the Section Sensing and Imaging)
  • Article
  • Open Access
11 Citations
6,226 Views
20 Pages

Motion Correction for Brain MRI Using Deep Learning and a Novel Hybrid Loss Function

  • Lei Zhang,
  • Xiaoke Wang,
  • Michael Rawson,
  • Radu Balan and ,
  • Edward H. Herskovits,
  • Elias R. Melhem,
  • Linda Chang,
  • Ze Wang and
  • Thomas Ernst
  • + 4 authors+ 0 author

15 May 2024

Purpose: Motion-induced magnetic resonance imaging (MRI) artifacts can deteriorate image quality and reduce diagnostic accuracy, but motion by human subjects is inevitable and can even be caused by involuntary physiological movements. Deep-learning-b...

(This article belongs to the Special Issue Machine Learning Algorithms for Biomedical Image Analysis and Applications)
  • Feature Paper
  • Article
  • Open Access
25 Citations
8,685 Views
19 Pages

Motion Artifact Quantification and Sensor Fusion for Unobtrusive Health Monitoring

  • Christoph Hoog Antink,
  • Florian Schulz,
  • Steffen Leonhardt and
  • Marian Walter

25 December 2017

Sensors integrated into objects of everyday life potentially allow unobtrusive health monitoring at home. However, since the coupling of sensors and subject is not as well-defined as compared to a clinical setting, the signal quality is much more var...

(This article belongs to the Special Issue Sensors for Health Monitoring and Disease Diagnosis)
  • Article
  • Open Access
37 Citations
6,808 Views
14 Pages

A Motion Artifact Correction Procedure for fNIRS Signals Based on Wavelet Transform and Infrared Thermography Video Tracking

  • David Perpetuini,
  • Daniela Cardone,
  • Chiara Filippini,
  • Antonio Maria Chiarelli and
  • Arcangelo Merla

28 July 2021

Functional near infrared spectroscopy (fNIRS) is a neuroimaging technique that allows to monitor the functional hemoglobin oscillations related to cortical activity. One of the main issues related to fNIRS applications is the motion artefact removal,...

(This article belongs to the Special Issue Biomedical Infrared Imaging: From Sensors to Applications Ⅱ)
  • Data Descriptor
  • Open Access
112 Citations
25,768 Views
13 Pages

24 December 2016

Wearable heart rate sensors such as those found in smartwatches are commonly based upon Photoplethysmography (PPG) which shines a light into the wrist and measures the amount of light reflected back. This method works well for stationary subjects, bu...

  • Article
  • Open Access

Improving Wearable PPG Monitoring with Morphology-Aware and Learning-Driven Heartbeat Detection

  • Pietro Chierico,
  • Daniel Suárez,
  • Lorenzo Fácila,
  • Fernando Hornero and ,
  • Raúl Alcaraz and
  • José J. Rieta
  • + 1 author+ 0 author
Sensors2026, 26(21), 6912;https://doi.org/10.3390/s26216912 
(registering DOI)

31 October 2026

Photoplethysmography (PPG) is a widely used, non-invasive technique for heart rate monitoring, but its reliability is often compromised by noise and motion artifacts (MAs). This study presents the Peakwise Correlation Pulse Detector (PCPD), an algori...

(This article belongs to the Special Issue Advanced Sensing and AI-Driven Technologies for Physiological Monitoring and Health Assessment)
  • Article
  • Open Access
33 Citations
5,787 Views
21 Pages

Pulse wave (PW) measurement is a highly prominent technique, used in biomedical diagnostics. Development of novel PW sensors with increased accuracy and reduced susceptibility to motion artifacts will pave the way to more advanced healthcare technolo...

(This article belongs to the Special Issue Optical Fiber Interferometric Sensors: New Production Methodologies and Novel Applications)
  • Review
  • Open Access
469 Views
29 Pages

Enhancing Cerebral Blood Flow Quantification: A Comprehensive Review of Denoising, Artifact Correction, and Simulation in Arterial Spin Labeling MRI

  • Shyna A,
  • Jini Raju,
  • Ansamma John,
  • Chandrasekharan Kesavadas and ,
  • Aditya Ajith,
  • Manu J. Pillai,
  • Shameem Ansar and
  • Ginu Rajan
  • + 3 authors+ 0 author

17 August 2026

Arterial Spin Labeling (ASL) Magnetic Resonance Imaging (MRI) is a noninvasive imaging technique used to quantify cerebral blood flow (CBF) by using magnetically labeled arterial blood water as an endogenous tracer. Although ASL eliminates the need f...

(This article belongs to the Special Issue Intelligent MRI Sensing: Novel Acquisition and AI-Powered Diagnosis)

of 5