Skip to Content

1,353 Results Found

  • Article
  • Open Access
16 Citations
4,058 Views
17 Pages

26 June 2018

Voltage source converters (VSCs) are able to provide both positive- and negative-sequence short circuit currents under unbalanced faults. Their short circuit responses can be significantly different from those of conventional synchronous generators....

(This article belongs to the Section F: Electrical Engineering)
  • Article
  • Open Access
1,309 Views
21 Pages

26 July 2025

A quantitative analysis of the fault transient is critical for system resilience assessment and protection coordination. Focusing on hybrid modular multilevel converter (MMC)-based HVDC architecture with enhanced fault ride-through (FRT) capability,...

(This article belongs to the Special Issue Power Electronics: Control and Applications)
  • Article
  • Open Access
15 Citations
3,908 Views
18 Pages

20 November 2020

A saturated iron-core superconducting fault current limiter (SI-SFCL) can significantly limit the magnitude of the fault current and reduce the stress on circuit breakers in direct current (DC) power systems. The SI-SFCL consists of three main parts:...

(This article belongs to the Section F: Electrical Engineering)
  • Article
  • Open Access
5 Citations
2,559 Views
15 Pages

29 July 2025

In this study, a current vector pattern is analyzed for inter-turn fault (ITF) diagnosis of induction machines (IMs), and an ITF diagnosis algorithm is proposed. When an ITF occurs in IMs, a negative-sequence current is generated due to fault resista...

(This article belongs to the Special Issue Fault Diagnosis for Electrical Machines, Power Electronics, and Drives)
  • Article
  • Open Access
19 Citations
5,947 Views
24 Pages

13 February 2025

Maintenance strategies such as condition-based maintenance and predictive maintenance of machines have gained importance in industrial automation firms as key concepts in Industry 4.0. As a result, online condition monitoring of electromechanical sys...

(This article belongs to the Special Issue Advanced Fault Diagnosis and Health Monitoring Techniques for Complex Engineering Systems: 2nd Edition)
  • Article
  • Open Access
16 Citations
3,546 Views
21 Pages

17 August 2023

Using vibration signals for bearing fault diagnosis can generally achieve good diagnostic results. However, it is not suitable for practical industrial applications due to the restricted installation and high cost of vibration sensors. Therefore, the...

(This article belongs to the Special Issue Intelligent Fault Diagnosis and Monitoring)
  • Article
  • Open Access
711 Views
34 Pages

A Novel Statistical Method for Spectral Analysis of A Short-Duration Signal and Its Application to Current Data for Stator Fault Diagnosis

  • Justyna Hebda-Sobkowicz,
  • Anna Michalak,
  • Jacek Wodecki,
  • Radosław Zimroz and ,
  • Marcin Wolkiewicz and
  • Krzysztof Szabat
  • + 1 author+ 0 author

6 March 2026

In this paper, a novel approach for fault detection in the stator windings of induction motors is presented. The procedure is based on spectral analysis of the current signal. However, due to the specific target application, short duration signals (0...

(This article belongs to the Special Issue Electric Machinery, Transformers, and Modern Drives—4th Edition)
  • Article
  • Open Access
5 Citations
2,734 Views
16 Pages

10 October 2023

The transient characteristics of wind farms in groups are quite different; in addition, there is a strong coupling between the wind farms and the grid, and these factors make the fault analysis of the grid with wind farm groups complicated. In order...

(This article belongs to the Section Fault Diagnosis & Sensors)
  • Article
  • Open Access
293 Views
31 Pages

A Physics-Informed Temporal Convolutional Network for Joint Fault Diagnosis and Calibrated Severity Estimation in Induction Motors Through Motor Current Signature Analysis

  • Ahmed Mohammed,
  • Badr M. Abdullah,
  • Qian Zhang,
  • Omar Aldhaibani and ,
  • Jeff Cullen,
  • Alessandro Raschella and
  • Amer Salih
  • + 2 authors+ 0 author

9 October 2026

Motor current signature analysis (MCSA) enables non-invasive condition monitoring of three-phase induction motors, but most published studies use short laboratory records with artificially seeded faults and report only a discrete fault label without...

(This article belongs to the Section Machines Testing and Maintenance)
  • Article
  • Open Access
17 Citations
4,659 Views
22 Pages

Characteristic Analysis and Fault-Tolerant Control of Circulating Current for Modular Multilevel Converters under Sub-Module Faults

  • Wen Wu,
  • Xuezhi Wu,
  • Jingyuan Yin,
  • Long Jing and ,
  • Shuai Wang and
  • Jinke Li
  • + 1 author+ 0 author

10 November 2017

A modular multilevel converter (MMC) is considered to be a promising topology for medium- or high-power applications. However, a significantly increased amount of sub-modules (SMs) in each arm also increase the risk of failures. Focusing on the fault...

  • Proceeding Paper
  • Open Access
13 Citations
3,724 Views
7 Pages

15 September 2022

Fault diagnosis in electrical drives can be very difficult, especially when the input data come from an operating electrical machine. The occurrence of inter-turn short-circuit (ITSC) faults is one of the most dangerous electrical machine failures, a...

(This article belongs to the Proceedings of The 1st International Electronic Conference on Machines and Applications)
  • Article
  • Open Access
13 Citations
2,892 Views
22 Pages

6 August 2025

Inter-turn short-circuit faults in induction motors might lead to overheating, torque imbalances, and eventual motor failure. This paper presents a fault detection framework for accurately identifying ITSC faults under various operating conditions. T...

(This article belongs to the Special Issue Advanced Sensor Technologies for Fault Diagnosis and Condition Monitoring)
  • Article
  • Open Access
1 Citations
1,322 Views
18 Pages

11 February 2025

The fault current in MMC HVDC systems suffers from a quick rising rate and no zero-cross problems, which makes it hard to cut off and has become the main problem when promoting MMC dc systems. Among the different types of faults, the pole-to-pole fau...

(This article belongs to the Special Issue The Hybrid AC-DC Power System Coordinated Control and Operation Technology, 2nd Edition)
  • Feature Paper
  • Article
  • Open Access
39 Citations
6,493 Views
20 Pages

18 February 2022

This paper describes a vector-controlled Permanent Magnet Synchronous Motor (PMSM) drive system with the current sensor fault detection mechanism. In general, the control structure is based on the well-known Field Oriented Control (FOC) algorithm. Th...

(This article belongs to the Section Electrical Engineering Design)
  • Article
  • Open Access
21 Citations
5,664 Views
14 Pages

1 February 2020

As a key component to ensure the safe operation of the power grid, mechanical defect diagnosis technology of gas-insulated switchgear (GIS) during operation is often neglected. At present, GIS mechanical fault detection based on vibration information...

(This article belongs to the Special Issue Vibration-Based Structural Health Monitoring)
  • Article
  • Open Access
10 Citations
4,327 Views
16 Pages

23 January 2018

AC (alternating current) system backup protection setting calculation is an important basis for ensuring the safe operation of power grids. With the increasing integration of modular multilevel converter based high voltage direct current (MMC-HVDC) i...

(This article belongs to the Section F: Electrical Engineering)
  • Article
  • Open Access
7 Citations
3,638 Views
13 Pages

Two Current-Based Methods for the Detection of Bearing and Impeller Faults in Variable Speed Pumps

  • Vincent Becker,
  • Thilo Schwamm,
  • Sven Urschel and
  • Jose Alfonso Antonino-Daviu

26 July 2021

The growing number of variable speed drives (VSDs) in industry has an impact on the future development of condition monitoring methods. In research, more and more attention is being paid to condition monitoring based on motor current evaluation. Howe...

(This article belongs to the Special Issue Novel Approaches to Electrical Machine Fault Diagnosis)
  • Article
  • Open Access
6 Citations
2,906 Views
18 Pages

31 July 2023

HVDC is an important part of reducing energy transmission losses and maintaining energy sustainability. Commutation failure is the most common fault in HVDC systems, but existing commutation failure analysis approaches for HVDC systems do not conside...

(This article belongs to the Topic Modeling, Optimization, and Control of Energy Systems)
  • Article
  • Open Access
9 Citations
7,199 Views
24 Pages

Short-Circuit Fault Current Modeling of a DC Light Rail System with a Wayside Energy Storage Device

  • Petru Valentin Radu,
  • Miroslaw Lewandowski,
  • Adam Szelag and
  • Marcin Steczek

11 May 2022

This paper proposes a simulation model to calculate short-circuit fault currents in a DC light rail system with a wayside energy storage device. The simulation model was built in MATLAB/Simulink using the electrical information required to define a c...

(This article belongs to the Special Issue Advances in Electric Transport System)
  • Article
  • Open Access
2 Citations
2,003 Views
14 Pages

A Practical Pole-to-Ground Fault Current Calculation Method for Symmetrical Monopole DC Grids

  • Ying Xu,
  • Wei Kuang,
  • Baohong Li,
  • Xiaopeng Li and ,
  • Tierui Zou,
  • Qin Jiang and
  • Yiping Luo
  • + 2 authors+ 0 author

29 October 2024

At present, DC grid fault current analyses are usually based on numerical analyses and/or simulations. To make fault current analyses more practical and convenient, this study proposes a fast fault current level assessment methodology that is applica...

(This article belongs to the Section Industrial Electronics)
  • Article
  • Open Access
3 Citations
1,743 Views
24 Pages

Broken Rotor Bar Fault Detection for Inverter-Fed Induction Motor with Negative-Sequence Current Analysis

  • Sarvarbek Ruzimov,
  • Jianzhong Zhang,
  • Xu Huang and
  • Muhammad Shahzad Aziz

18 November 2025

This study examines the effectiveness of negative-sequence current analysis in identifying broken rotor bars for inverter-fed induction motors under different load and speed conditions. To improve diagnostic reliability, inverter-induced harmonics in...

(This article belongs to the Special Issue Smart Sensing, Innovative Analysis and Optimal Operation of Distribution Systems)
  • Article
  • Open Access
14 Citations
7,062 Views
15 Pages

Short-Circuit Fault Diagnosis on Induction Motors through Electric Current Phasor Analysis and Fuzzy Logic

  • Josue A. Reyes-Malanche,
  • Francisco J. Villalobos-Pina,
  • Efraın Ramırez-Velasco,
  • Eduardo Cabal-Yepez and ,
  • Geovanni Hernandez-Gomez and
  • Misael Lopez-Ramirez
  • + 1 author+ 0 author

3 January 2023

Online monitoring of induction motors has increased significantly in recent years because these devices are essential components of any industrial process. Incipient fault detection in induction motors avoids interruptions in manufacturing processes...

(This article belongs to the Section F1: Electrical Power System)
  • Article
  • Open Access
11 Citations
3,148 Views
16 Pages

A Layering Linear Discriminant Analysis-Based Fault Diagnosis Method for Grid-Connected Inverter

  • Guangfeng Jin,
  • Tianzhen Wang,
  • Yassine Amirat,
  • Zhibin Zhou and
  • Tao Xie

Grid-connected inverters are the core equipment for connecting marine energy power generation systems to the public electric utility. The variation of current sensor fault severity will make fault samples multimodal. However, linear discriminant anal...

(This article belongs to the Section Ocean Engineering)
  • Article
  • Open Access
29 Citations
4,293 Views
22 Pages

28 February 2023

In this paper, a current sensor fault detection mechanism based on multilayer perceptron (MLP) in a permanent magnet synchronous motor (PMSM) drive system is presented. The solution for the PMSM was previously described and tested only in simulation...

(This article belongs to the Special Issue Advanced Fault Detection, Diagnosis and Prognosis in a Context of Renewable Power Generation)
  • Article
  • Open Access
21 Citations
4,862 Views
20 Pages

Three-Level NPC Inverter Incipient Fault Detection and Classification using Output Current Statistical Analysis

  • Mehdi Baghli,
  • Claude Delpha,
  • Demba Diallo,
  • Abdelhamid Hallouche and ,
  • David Mba and
  • Tianzhen Wang
  • + 1 author+ 0 author

9 April 2019

This paper deals with open switch Fault Detection and Diagnosis (FDD) in three-level Neutral Point Clamped (NPC) inverter for electrical drives. The approach is based on the already available phase current time series measurements for different opera...

(This article belongs to the Special Issue Fault Diagnosis and Fault-Tolerant Control)
  • Feature Paper
  • Article
  • Open Access
10 Citations
3,291 Views
18 Pages

20 September 2022

In this paper the current sensor fault detector for the permanent-magnet synchronous motor drive system has been presented. The solution is a known method used for induction motor drive systems, tested by authors in simulation for the PMSM drive syst...

(This article belongs to the Special Issue Machine Fault Diagnostics and Prognostics Volume III)
  • Article
  • Open Access
18 Citations
3,869 Views
15 Pages

1 March 2021

Settings of protection are essential to ensure the sensitivity and selectivity needed to detect defects. Making the correct settings requires the calculation of the fault currents with as little error as possible. Fault currents are influenced by the...

  • Article
  • Open Access
15 Citations
2,393 Views
17 Pages

A Modified EMD Technique for Broken Rotor Bar Fault Detection in Induction Machines

  • Md. Shamsul Arifin,
  • Wilson Wang and
  • Mohammad Nasir Uddin

11 August 2024

Induction machines (IMs) are commonly used in various industrial sectors. It is essential to recognize IM defects at their earliest stage so as to prevent machine performance degradation and improve production quality and safety. This work will focus...

(This article belongs to the Special Issue Sensors for Predictive Maintenance of Machines)
  • Article
  • Open Access
27 Citations
4,377 Views
18 Pages

Transformer Core Fault Diagnosis via Current Signal Analysis with Pearson Correlation Feature Selection

  • Daryl Domingo,
  • Akeem Bayo Kareem,
  • Chibuzo Nwabufo Okwuosa,
  • Paul Michael Custodio and
  • Jang-Wook Hur

29 February 2024

The role of transformers in power distribution is crucial, as their reliable operation is essential for maintaining the electrical grid’s stability. Single-phase transformers are highly versatile, making them suitable for various applications r...

(This article belongs to the Special Issue Emerging Theory and Applications in Fault Diagnosis and Motor Drive Control)
  • Article
  • Open Access
16 Citations
3,594 Views
18 Pages

Combined Operation Analysis of a Saturated Iron-Core Superconducting Fault Current Limiter and Circuit Breaker for an HVDC System Protection

  • Jae-In Lee,
  • Van Quan Dao,
  • Minh-Chau Dinh,
  • Seok-ju Lee and ,
  • Chang Soon Kim and
  • Minwon Park
  • + 1 author+ 0 author

30 November 2021

Recently, in order to overcome the difficulties of interrupting fault currents in multi-terminal direct current systems (MTDC), studies combining a saturated iron-core type superconducting current limiter (SFCL) and a direct current circuit breaker (...

(This article belongs to the Section A1: Smart Grids and Microgrids)
  • Article
  • Open Access
13 Citations
2,110 Views
22 Pages

Innovative Fault Current Evaluation Method for Active DC Grids

  • Julian Valbuena Godoy,
  • Simone Negri,
  • Francesca Oliva,
  • Antonello Antoniazzi and
  • Roberto Sebastiano Faranda

22 February 2024

DC smart grids are a promising solution for the efficient integration of renewable energy sources and loads. Still, their widespread adoption is hindered by significant challenges related to fault response, identification, and clearance. The traditio...

(This article belongs to the Special Issue Power Electronics in Italy—Emerging Electronic Power Technologies and Electronic Devices in the Industrial 4.0 Era)
  • Article
  • Open Access
27 Citations
4,275 Views
20 Pages

23 July 2020

Vibration signal is often used in traditional gear fault diagnosis techniques. However, the working face of the scraper conveyor is narrow, harsh and easily explosive, so it is inconvenient to obtain vibration signals by installing sensors. Motor cur...

(This article belongs to the Special Issue Machine Fault Diagnostics and Prognostics II)
  • Article
  • Open Access
2 Citations
1,423 Views
22 Pages

8 March 2025

Motor current analysis is useful for ensuring the safety and reliability of electromechanical systems. However, for gearboxes, the commonly used methods of detecting faulty frequency sidebands are easily disturbed by installation errors, inherent har...

(This article belongs to the Section Machines Testing and Maintenance)
  • Article
  • Open Access
6 Citations
2,682 Views
18 Pages

Impact of Inter-Turn Short Circuit in Excitation Windings on Magnetic Field and Stator Current of Synchronous Condenser under Unbalanced Voltage

  • Junqing Li,
  • Chengzhi Zhang,
  • Yuling He,
  • Xiaodong Hu and ,
  • Jiya Geng and
  • Yapeng Ma
  • + 1 author+ 0 author

29 July 2023

Inter-turn short circuit in the excitation windings of synchronous condensers is a common fault that directly impacts their normal operation. However, current fault analysis and diagnosis of synchronous condensers primarily rely on voltage-balanced c...

(This article belongs to the Special Issue Modeling, Control and Diagnosis of Electrical Machines and Devices)
  • Article
  • Open Access
26 Citations
5,009 Views
16 Pages

21 November 2019

Broken rotor bar (BRB) faults are one of the most common faults in induction motors (IM). One or more broken bars can reduce the performance and efficiency of the IM and hence waste the electrical power and decrease the reliability of the whole mecha...

(This article belongs to the Special Issue Diagnostics and Condition Monitoring Technologies for Assuring Asset Performances)
  • Article
  • Open Access
11 Citations
4,649 Views
12 Pages

An induction motor is a key device for an industrial machine. The installation misalignment of the motor will result in derating problems and energy consumption that is generally used to analyze signal faults using the fast Fourier transform (FFT) me...

  • Article
  • Open Access
15 Citations
4,318 Views
17 Pages

Hybrid Wavelet–CNN Fault Diagnosis Method for Ships’ Power Systems

  • Dimitrios Paraskevopoulos,
  • Christos Spandonidis and
  • Fotis Giannopoulos

8 February 2023

Three-phase induction motors (IMs) are considered an essential part of electromechanical systems. Despite the fact that IMs operate efficiently under harsh environments, there are many cases where they indicate deterioration. A crucial type of fault...

  • Article
  • Open Access
16 Citations
3,168 Views
18 Pages

26 September 2018

The conversion system is a major contributor to failure rates. These faults lead to time and cost consuming. Fault diagnosis capabilities pay as a solver to achieve a steady system. This paper presents a full analysis of permanent magnet synchronous...

  • Article
  • Open Access
3 Citations
1,892 Views
20 Pages

PumpSpectra: An MCSA-Based Platform for Fault Detection in Centrifugal Pump Systems

  • Hamza Adaika,
  • Zoheir Tir,
  • Mohamed Sahraoui and
  • Khaled Laadjal

12 November 2025

Reliable detection of faults in centrifugal pump systems is challenging in industrial environments due to harsh operating conditions, limited sensor access, and the need for fast, explainable decisions. We developed PumpSpectra, an industrial Motor C...

(This article belongs to the Special Issue Sensors, Systems and Methods for Power Quality Measurements)
  • Proceeding Paper
  • Open Access
6 Citations
3,895 Views
10 Pages

Mechanical Failure Detection in Induction Motors Using Stator Current and Stray Flux Analysis Techniques

  • Remus Pusca,
  • Salim Sbaa,
  • Noureddine Bessous,
  • Raphaël Romary and
  • Radouane Bousseksou

11 February 2022

Because of its benefits, an induction machine is used in a variety of applications. The machine’s robustness is one of its benefits. Generally, mechanical faults cause torque oscillations, eccentricity, and vibration, which affect the stator cu...

(This article belongs to the Proceedings of The 1st International Conference on Computational Engineering and Intelligent Systems)
  • Article
  • Open Access
4 Citations
3,064 Views
20 Pages

An improved hybrid submodule employs a direct current (DC) short current protection function to improve the reliability of a high-voltage direct current (HVDC) system. However, it increases the number of circuit components to implement the protection...

(This article belongs to the Special Issue Modeling and Control of Power Electronic Converters in Renewable Energy and Smart Grid Systems)
  • Article
  • Open Access
13 Citations
3,662 Views
26 Pages

6 September 2024

Power transformers are vital and costly components in power systems, essential for ensuring a reliable and uninterrupted supply of electrical energy. Their protection is crucial for improving reliability, maintaining network stability, and minimizing...

  • Article
  • Open Access
6 Citations
2,637 Views
20 Pages

21 November 2023

The high-level proliferation of inverter-interfaced distributed generators (IIDGs) in modern distribution networks (DNs) has changed system topologies and fault current signatures, which compromises the protective relays in DNs. Investigating IIDG fa...

(This article belongs to the Special Issue Situational Awareness and Protection Technologies for Low-Carbon Economic Operation of New Power Systems)
  • Article
  • Open Access
873 Views
18 Pages

15 December 2025

Static eccentricity is an important early-stage fault in marine diesel generators, as small air-gap deviations caused by misalignment or mechanical wear can escalate into bearing damage and rotor–stator contact. To address the challenge of dete...

(This article belongs to the Section Physical Sensors)
  • Article
  • Open Access
19 Citations
2,987 Views
25 Pages

Motor Current Signature Analysis (MCSA) is a commonly used non-invasive method for diagnosing faults in electric motors. Although MCSA provides significant advantages—current signals are easy to acquire and inherently robust against noise&mdash...

(This article belongs to the Special Issue AI in Signal and Image Processing)
  • Article
  • Open Access
9 Citations
3,820 Views
13 Pages

Fault Arc Detection Method Based on Improved ShuffleNet V2 Network

  • Yuehua Huang,
  • Yun Lu,
  • Liping Fan,
  • Kun Xiang and
  • Hui Ma

6 January 2025

Fault arcs exhibit randomness, with current waveforms closely mirroring those of standard nonlinear load operations, posing challenges for traditional series fault arc detection methods. This study presents an improved detection approach using a ligh...

(This article belongs to the Section Automation Control Systems)
  • Article
  • Open Access
3 Citations
2,444 Views
20 Pages

28 September 2021

A fault current limiter (FCL) may be applied to assist the low-voltage ride-through (LVRT) of a doubly fed induction generator (DFIG). FCLs with fixed impedance, lack the flexibility to adjust their impedance to adapt to different LVRT scenarios. The...

(This article belongs to the Special Issue Voltage Stability of Microgrids in Power Systems)
  • Article
  • Open Access
8 Citations
5,525 Views
23 Pages

8 August 2022

Distributed energy resources (DERs), recently introduced into distribution systems, are mainly inverter-based distributed generations (IBDGs), which have different short-circuit behaviors from conventional synchronous-based distributed generations (S...

(This article belongs to the Section Resources and Sustainable Utilization)
  • Article
  • Open Access
7 Citations
5,480 Views
14 Pages

Grid Connection Studies for Large-Scale Offshore Wind Farms Considering High Penetration of Regional Renewables

  • Namki Choi,
  • Beomju Kim,
  • Dohyuk Kim,
  • Bohyun Park and ,
  • Sangsoo Kim and
  • Byongjun Lee
  • + 1 author+ 0 author

17 January 2022

There is a global focus on adding renewable energy sources to the mix of energy supplies. In this study, the grid connections for large-scale offshore wind farms in areas that have high penetration of renewable energy sources were examined. System st...

(This article belongs to the Special Issue Sustainability of Future Power Systems: Climate Change Impacts, System Reliability, Renewable Energy Technologies and Grid Integration)
  • Article
  • Open Access
12 Citations
4,247 Views
13 Pages

Fault Investigation of Circulation Pumps to Detect Impeller Clogging

  • Vincent Becker,
  • Thilo Schwamm,
  • Sven Urschel and
  • Jose Alfonso Antonino-Daviu

27 October 2020

Pumps have a wide range of applications. Methods for fault detection of motors are increasingly being used for pumps. In the context of this paper, a test bench is built to investigate circulation pumps for faults. As a use case, the fault of impelle...

(This article belongs to the Special Issue Modeling, Design and Control of Electric Machines)

of 28