- Article
There have been several attempts to improve the cellular and molecular interactions at the tissue–implant interface. Here, the biocompatibility of titanium-based implants (e.g., Grade 2 Titanium alloy (Ti-40) and titanium–niobium alloy (T...
There have been several attempts to improve the cellular and molecular interactions at the tissue–implant interface. Here, the biocompatibility of titanium-based implants (e.g., Grade 2 Titanium alloy (Ti-40) and titanium–niobium alloy (T...
Titanium-based laminated and hybrid architectures have emerged as an attractive approach for overcoming limitations associated with conventional homogeneous structural materials. By combining titanium alloys and metal matrix composites within heterog...
Titanium dioxide (TiO2) materials have been intensively studied in the past years because of many varied applications. This mini review article focuses on TiO2 micro and nano architectures with the prevalent crystal structures (anatase, rutile, brook...
The TC11 α + β dual-phase titanium alloy exhibits limited room-temperature ductility (3.3 × 10−4 s−1: elongation 13.8%) but achieves significant superplasticity at 900 °C (3.3 × 10−4 s−1: elongation...
Titanium and its alloys are widely used in cardiovascular devices because of their favorable mechanical properties, corrosion resistance, and biocompatibility. Nevertheless, their surfaces do not fully prevent nonspecific protein adsorption, platelet...
This work focused on studying the influence of dyes, including a thiophene derivative dye with a cyanoacrylic acid group ((E)-2-cyano-3-(3′,3′′,3′′′-trihexyl-[2,2′:5′,2′′:5′′,2&p...
Extensive production and use of nanomaterials (NMs), such as titanium dioxide (TiO2), raises concern regarding their potential adverse effects to humans. While considerable efforts have been made to assess the safety of TiO2 NMs using in vitro and in...
The carbon-supersaturated SKD11 punch was proposed as a green, or, a galling-free, long-life and low energy-consuming forging tool of pure titanium and β-titanium alloy that works with low friction and less work hardening and without galling. Th...
Dense β-SiC coating with 3C-structure was utilized as a dry cold forging punch and core-die. Pure titanium T328H wires of industrial grade II were employed as a work material. No adhesion or galling of metallic titanium was detected on the conta...
The interface between a dental implant and an abutment is stabilized by two mechanical characteristics: a preload of an abutment screw and the friction between the contact surfaces of the implant and the abutment. These mechanical properties are quan...
We describe the magnetic properties of thin iron films deposited on the nanoporous titanium oxide templates and analyze their dependance on nanopore radius. We then compare the results to a continuous iron film of the same thickness. Additionally, we...
An investigation was conducted on electron beam-welded and additively manufactured joints on a thick-walled titanium alloy utilizing in situ laser beam deposition and electron beam welding techniques. The surface morphology, microstructural character...
Multifunctionalizable hydrogel coatings on titanium interfaces are useful in a wide range of biomedical applications utilizing titanium-based materials. In this study, furan-protected maleimide groups containing multi-clickable biocompatible hydrogel...
To explore the effect of different explosive charge height parameters on the bonding interface of titanium–aluminum multilayer composite plates during explosion welding, the smooth particle dynamics method (SPH method) was used to simulate the...
The article examines and analyzes the use of composite materials, such as carbon fiber-reinforced plastic (CFRP) and glass fiber-reinforced plastic (GFRP), in new-generation aircraft. Comparative studies were conducted on these composite materials al...
In order to solve the problem of a thin deposition layer on the titanium alloy in the traditional friction surfacing process of dissimilar Ti/Al metals, new shoulder-restricted friction deposition (SRFD) equipment was successfully developed by introd...
The paper considers the issues of interaction of the molten metal at the interface of explosively welded NiCr/titanium alloy laminated composites with the reaction zone formed during heat treatment, as well as the features of its destruction after we...
This study demonstrates the potential of the use of Ni/Al nanolayers for joining dissimilar titanium alloys. For this purpose, a detailed microstructural characterization of the diffusion bonding interfaces of TiAl to Ti6Al4V, TiAl to TiNi and TiNi t...
The influences of Li content on the corrosion behavior of TC4 (Ti6Al4V) titanium alloy were explored when the TC4 titanium alloy was immersed in Al–Li alloy melt containing 0%, 1%, and 2% lithium at 680 °C, 700 °C, and 720 °C for 0.5 h, 1 h, and 2 h....
Polymeric dielectrics have garnered significant interest worldwide due to their excellent comprehensive performance. However, developing polymeric dielectric films with high permittivity (εr) and breakdown strength (Eb) and low dielectric los...
The adsorption characteristics of corrosive anions (Cl−, HS−, S2−, HCO3− and CO32−) on TiO2 of TC4 titanium alloy in a NaCl solution containing H2S and CO2 were studied by density functional theory (DFT). The stable adso...
Dye-sensitized solar cells (DSSCs) remain promising low-cost photovoltaic technologies because of their simple fabrication, tunable optical properties, and effective operation under low-light conditions. Titanium dioxide (TiO2) is the most widely use...
It has been established that gold, when in nanoparticle (NP) form and in contact with reducible oxides, can promote oxidation reactions under mild conditions. Here, we report results from our exploration of the catalytic oxidation of carbon monoxide...
This paper studies the weld interface microstructure and mechanical properties of AlMg6-stainless steel and AlMg6-titanium bimetals produced using explosive welding. The microhardness (HV), tear strength, and microstructure of the weld seams were eva...
Aluminum matrix composites reinforced with multiwalled carbon nanotubes (MWCNTs) are promising materials for applications in various high-tech industries. Control over the processes of interfacial interaction in Al/MWCNT composites is important to ac...
Titanium dioxide (TiO2) has emerged as a candidate anode material for sodium-ion batteries (SIBs). However, their applications still face challenges of poor rate performance and low initial coulomb efficiency (ICE), which are induced by the unstable...
Titanium is a commonly used material in aviation, aerospace, and military applications, due to the outstanding mechanical properties of titanium and its alloys. However, its relatively low thermal conductivity restricts its extended usage. The use of...
The interfacial polycondensation of titanium dioxide was studied at the bare and fiberglass membrane supported polarized liquid–liquid interface (LLI). Titanium dioxide synthesis was derived from the titanium (IV) tetrabutoxide (initially dissolved i...
In this paper, the influence of the extra solid phase reaction on the interface structure and mechanical properties of titanium carbonitride-based cermets were investigated. The extra solid phase reaction in the preparation process of cermets could i...
The paper presents the issues of metal surface treatment in fibre metal laminates (FML) to obtain high adhesion at the metal–composite interface. Aluminium 2024-T3 and titanium Grade 2 were analysed. The metal surface modifications were carried...
The aim of the present study was to evaluate the in vivo bone response to an additively manufactured zirconia surface compared to osseointegration into titanium (Ti) surfaces. Scanning electron microscopy, confocal laser scanning microscopy, and elec...
Graphene (GR) demonstrates significant potential in enhancing the mechanical performance of titanium matrix composites (TMCs), particularly by improving their tensile strength, fracture toughness, and fatigue resistance, thereby optimizing the overal...
21 March 2018
Nanoparticles (NP)-based inhalation systems for drug delivery can be administered in liquid form, by nebulization or using pressurized metered dose inhalers, and in solid form by means of dry powder inhalers. However, NP delivery to the lungs has man...
We evaluated the shear bond strength of bone–implant contact, or osseointegration, in the rabbit tibia model, and compared the strength between grades 2 and 4 of commercially pure titanium (cp-Ti). A total of 13 grades 2 and 4 cp-Ti implants we...
The object of this study is the formation of intermetallic phases (IMPhs) in the heat-affected zone (HAZ) of joints of steel–titanium bimetal plates produced by arc welding. A titanium layer (2 mm) was welded by the plasma method (PAW), a barri...
Osseointegration is a prerequisite for the long-term success of implants. Titanium implants are preferred for their biocompatibility and mechanical properties. Nonetheless, the need for early and immediate loading requires enhancing these properties...
Recent studies show that titanium (Ti)-based alloys combine established mechanical strength, corrosion resistance, and biocompatibility with emerging electrical and electrochemical properties relevant to bioelectronics. The main goal of the present m...
Background: Titanium implant osseointegration is hierarchically governed by surface properties directing protein adsorption, cell recognition, immune modulation, and bone formation. Photofunctionalization creates ultrahydrophilic surfaces by removing...
A complex study of the adhesion of multi-walled carbon nanotubes to a titanium surface, depending on the modes of irradiation with He+ ions of the “MWCNT/Ti” system, was conducted using atomic force microscopy and X-ray photoelectron spec...
CFRP/Ti stacks composed of carbon fiber-reinforced plastic composites (CFRP) and titanium alloys (Ti) are widely used in aerospace fields. However, in the integrated hole-making process of CFRP/Ti stacks, the machining characteristics of various mate...
This in vitro study aimed to assess the presence of microgaps at the implant–abutment interface in monolithic zirconia partial implant-supported fixed prostheses on transepithelial abutments versus Ti-base abutments. Methods: Sixty conical conn...
Background: The risk of impaired bone–pin interface strength in titanium (Ti) pins coated with fibroblast growth factor (FGF)–calcium phosphate (CP) composite layers is yet to be evaluated in a clinical study. This retrospective study use...
The adhesion properties of the TiAl/TiO2 interface are estimated in dependence on interfacial layer composition and contact configuration using the projector augmented wave method. It is shown that a higher value of the work of separation is obtained...
The detection of toxic insecticides is a major scientific and technological challenge. In this regard, imidacloprid is a neonicotinoid that is a systemic insecticide that can accumulate in agricultural products and affect human health. This work aims...
Unmodified Ti6Al4V can osseointegrate, but sometimes this capacity needs to be improved. This study aimed to see how much porosity improves osseointegration in a Ti6Al4V implant. Three types of Ti6Al4V cylindrical-shaped implants (13.00 mm length &ti...
Soft-tissue management is critical for guided bone regeneration (GBR), yet conventional titanium meshes lack the ability to regionally regulate fibroblast behavior where opposite biological responses are needed. Here, we fabricated two femtosecond-la...
Flexible biosensors offer rapid and low-cost diagnostics but are often limited by the mechanical and electrochemical instability of polymer-based designs in biological media. Here, we introduce a metallic flexible microcrack transducer that exploits...
Electron transport measurements on Co/TiN multilayers are employed to explore the effect of TiN layers on Co resistivity. For this, 50 nm thick multilayer stacks containing N = 1–10 individual Co layers that are separated by 1 nm thick TiN laye...
In this review, I examine the influence of nanoscale materials features on the hydrogen-metal interaction. The small system size, the abundance of surfaces/interfaces, and the spatial distribution of phases are the key factors to understand the hydro...
Microstructures and mechanical properties of Mg-9Al/Ti metallurgical bonding prepared by liquid-solid diffusion couples were investigated. The results indicate that a metallurgical bonding was formed at the interface Mg-9Al/Ti, and the Mg17Al12 phase...
of 13