Skip to Content

566 Results Found

  • Article
  • Open Access
11 Citations
3,682 Views
14 Pages

18 August 2023

Background: A very common technique for treating spinal deformities in children and adolescents is the use of segmental screws. In order to obtain proper stability and the best possible correction, the screws must first be precisely inserted. Additio...

(This article belongs to the Special Issue Improving Safety and Outcomes in Complex Spine Surgery: Advancements in Complication Prediction, Surgical Optimization, and Techniques)
  • Article
  • Open Access
12 Citations
3,606 Views
12 Pages

Medial Pedicle Pivot Point Using Preoperative Computed Tomography Morphometric Measurements for Cervical Pedicle Screw Insertion: A Novel Technique and Case Series

  • Ji-Won Kwon,
  • Edward O. Arreza,
  • Anthony A. Suguitan,
  • Soo-Bin Lee and ,
  • Sahyun Sung,
  • Yung Park,
  • Joong-Won Ha,
  • Tae Hyung Kim,
  • Seong-Hwan Moon and
  • Byung Ho Lee
  • + 5 authors+ 0 author

13 January 2022

This study describes a new and safe freehand cervical pedicle screw insertion technique using preoperative computed tomography (CT) morphometric measurements as a guide and a medial pedicle pivot point (MPPP) during the procedure. This study included...

(This article belongs to the Section Orthopedics)
  • Article
  • Open Access
8 Citations
9,791 Views
12 Pages

Alternative Pedicle Screw Design via Biomechanical Evaluation

  • Jiwoon Kwon,
  • Myung Heon Ha and
  • Moon Gu Lee

9 July 2020

With the recent increase in the elderly population, many people suffer from spinal diseases, and, accordingly, spinal fusion surgery using pedicle screws has been widely applied to treat them. However, most research on pedicle screw design has been f...

(This article belongs to the Special Issue Experimental Mechanics, Instrumentation and Metrology)
  • Article
  • Open Access
5 Citations
2,832 Views
10 Pages

Background: Although several biomechanical studies have been reported, few clinical studies have compared the efficacy of monoaxial and polyaxial pedicle screws in the surgical treatment of adolescent idiopathic scoliosis (AIS). This study aims to co...

(This article belongs to the Special Issue Scoliosis and Spinal Deformity: Current Diagnosis, Treatment and Clinical Management)
  • Article
  • Open Access
3 Citations
3,138 Views
11 Pages

The Incidence of Screw Failure in Fenestrated Polyaxial Pedicle Screws vs. Conventional Pedicle Screws in the Treatment of Adolescent Idiopathic Scoliosis (AIS)

  • Calogero Velluto,
  • Michele Inverso,
  • Maria Ilaria Borruto,
  • Andrea Perna and ,
  • Guido Bocchino,
  • Davide Messina and
  • Luca Proietti
  • + 2 authors+ 0 author

19 March 2024

Background: Adolescent idiopathic scoliosis (AIS) is a spinal pathology affecting 0.47–5.2% of the population, often requiring surgical intervention to control deformity progression. Posterior spinal instrumentation and fusion with pedicle scre...

(This article belongs to the Special Issue Spinal Deformity: Diagnosis, Complication and Treatment in Adolescent Patients)
  • Article
  • Open Access
5 Citations
3,571 Views
10 Pages

Mechanical Study of Various Pedicle Screw Systems including Percutaneous Pedicle Screw in Trauma Treatment

  • Yoshiaki Oda,
  • Tomoyuki Takigawa,
  • Yasuo Ito,
  • Haruo Misawa and ,
  • Tomoko Tetsunaga,
  • Koji Uotani and
  • Toshifumi Ozaki
  • + 2 authors+ 0 author

20 April 2022

Background and Objectives: Spine surgery using a percutaneous pedicle screw placement (PPSP) is widely implemented for spinal trauma. However, percutaneous systems have been reported to have weak screw–rod connections. In this study, convention...

(This article belongs to the Special Issue Minimally Invasive Spinal Treatment (MIST)—a New Concept in the Treatment of Spinal Diseases)
  • Article
  • Open Access
2 Citations
3,619 Views
9 Pages

A New Coupling Method for Accurate Measurement of Pedicle Screw Electrical Properties for Surgical Procedures

  • Pedro Fonseca,
  • Márcio Fagundes Goethel,
  • Ricardo Sebastião,
  • Manoela Vieira Sousa and ,
  • João Paulo Vilas-Boas,
  • Miguel Velhote Correia and
  • Manuel Gutierres
  • + 2 authors+ 0 author

22 October 2021

The objective of this study is to present a new coupling method in order to measure the electrical properties of titanium alloy pedicle screws used in spinal surgery and to compare it with other common methods of measurement. An experimental setup wa...

(This article belongs to the Section Biomedical Engineering)
  • Article
  • Open Access
1 Citations
1,789 Views
10 Pages

Power-Assisted Liposuction of the Superomedial Pedicle in Primary Wise-Pattern Reduction Mammoplasties

  • Ines Ana Ederer,
  • Shadi Najaf Zadeh,
  • Jonas Walber,
  • Florian Johannes Jung and ,
  • Abdul Rahman Jandali and
  • Alberto Franchi
  • + 1 author+ 0 author

24 June 2025

Background: Superomedial pedicle breast reduction is a widely performed procedure in plastic surgery. However, in cases of massive ptosis and excessively large breasts, achieving adequate pedicle reduction can be challenging. Direct excision of the t...

(This article belongs to the Special Issue Trends in Plastic and Reconstructive Surgery)
  • Article
  • Open Access
1 Citations
1,656 Views
11 Pages

Accuracy of Navigated High-Speed Drill-Assisted Cervical and Upper Thoracic Pedicle Screw Placement—A Single Center Experience with 1112 Pedicle Screws

  • Stefan Aspalter,
  • Nico Stroh-Holly,
  • Katja Höllmüller,
  • Armin Davachi and ,
  • Philip Rauch,
  • Stephan Heisinger,
  • Andreas Gruber and
  • Wolfgang Senker
  • + 3 authors+ 0 author

19 September 2025

Background/Objectives: While biomechanically superior, cervical pedicle screw placement is technically challenging, and therefore typically performed only in centers with the aid of navigation. The purpose of this study was to analyze the accuracy an...

(This article belongs to the Special Issue Advances in Spine Surgery: Best Practices and Future Directions)
  • Article
  • Open Access
2 Citations
3,018 Views
13 Pages

9 February 2023

To investigate the feasibility of using absorbable Mg alloy pedicle screws for atlantoaxial dislocation fixation, four types of Mg alloy pedicle screws of different thread forms were designed, and simulation analysis of the pull-out force was perform...

(This article belongs to the Section Biobased and Biodegradable Metals)
  • Communication
  • Open Access
3 Citations
3,166 Views
11 Pages

Innovative Pedicle Screw Insertion with Mixed Reality Technology Improves Insertion Accuracy in Spinal Surgery

  • Shintaro Obata,
  • Akira Shinohara,
  • Daigo Arimura,
  • Shunsuke Katsumi and ,
  • Hiroki Wakiya and
  • Mitsuru Saito
  • + 1 author+ 0 author

24 June 2025

The accuracy of pedicle screw insertion in pediatric scoliosis correction surgery using augmented reality technology in combination with a conventional navigation system was evaluated, and its usefulness was verified. A retrospective study of patient...

(This article belongs to the Section Biomedical Sensors)
  • Article
  • Open Access
1,758 Views
14 Pages

24 December 2025

Background: Dorsal pedicle skin flap application is a cover procedure frequently used by plastic surgeons to cover acute and chronic wounds, but preventing postoperative flap loss and disruption of the wound healing process has not yet been achieved....

(This article belongs to the Section Synthesis, Interfaces and Nanostructures)
  • Article
  • Open Access
1 Citations
1,515 Views
16 Pages

The Effect of the TiO2 Anodization Layer in Pedicle Screw Conductivity: An Analytical, Numerical, and Experimental Approach

  • Pedro Fonseca,
  • Márcio Fagundes Goethel,
  • João Paulo Vilas-Boas,
  • Manuel Gutierres and
  • Miguel Velhote Correia

The electrical stimulation of pedicle screws is a technique used to ensure its correct placement within the vertebrae pedicle. Several authors have studied these screws’ electrical properties with the objective of understanding if they are a po...

(This article belongs to the Special Issue Fundamentals of Orthopaedic Biomechanics: Implants, AI, and Innovation in Surgery)
  • Article
  • Open Access
6 Citations
4,941 Views
12 Pages

Using a 3D Navigation Template to Increase the Accuracy of Thoracic Pedicle Screws in Patients with Scoliosis

  • Cheng-Hao Jiang,
  • Yan Shi,
  • Yong-Mei Sun,
  • Ming-Jun Cai and ,
  • Hai-Long Wu,
  • Li-Sheng Hu,
  • Li-Min Yu,
  • Peng Wang,
  • Jie Shen and
  • Bin-Sheng Yu
  • + 6 authors+ 1 author

This study compares the accuracy and safety of pedicle screw placement using a 3D navigation template with the free-hand fluoroscopy technique in scoliotic patients. Fifteen scoliotic patients were recruited and divided into a template group (eight c...

(This article belongs to the Section Biomedical Biomaterials)
  • Article
  • Open Access
4 Citations
4,160 Views
9 Pages

Partial Threading of Pedicle Screws in a Standard Construct Increases Fatigue Life: A Biomechanical Analysis

  • Fon-Yih Tsuang,
  • Chia-Hsien Chen,
  • Lien-Chen Wu,
  • Yi-Jie Kuo and ,
  • Yueh-Ying Hsieh and
  • Chang-Jung Chiang
  • + 1 author+ 0 author

7 February 2021

This study proposed a pedicle screw design where the proximal 1/3 of the screw is unthreaded to improve fixation in posterior spinal surgery. This design was also expected to reduce the incidence of mechanical failure often observed when an unsupport...

(This article belongs to the Special Issue Musculoskeletal Research: Biomechanics and Biomaterials for the Treatment of Orthopedic Diseases)
  • Article
  • Open Access
7 Citations
5,286 Views
10 Pages

20 January 2022

Background: The purpose of this study was to evaluate the effectiveness of minimally invasive posterior mono-axial pedicle screws fixation in the treatment of thoracolumbar burst fractures. Methods: In the present study, we analyzed 98 patients retro...

(This article belongs to the Section Orthopedics)
  • Article
  • Open Access
4 Citations
3,430 Views
12 Pages

Biomechanical Comparison of Salvage Pedicle Screw Augmentations Using Different Biomaterials

  • Yun-Da Li,
  • Ming-Kai Hsieh,
  • De-Mei Lee,
  • Yi-Jiun Lin and ,
  • Tsung-Ting Tsai,
  • Po-Liang Lai and
  • Ching-Lung Tai
  • + 2 authors+ 0 author

3 August 2022

Allograft bone particles, hydroxyapatite/β-hydroxyapatite-tricalcium phosphate (HA/β-TCP), calcium sulfate (CS), and polymethylmethacrylate (PMMA) bone cement are biomaterials clinically used to fill defective pedicles for pedicle screw aug...

(This article belongs to the Section Biomedical Engineering)
  • Article
  • Open Access
1,213 Views
14 Pages

This study introduces a novel framework for defining screw trajectory that utilizes PointNet—a deep neural network trained on lumbar vertebrae point clouds—to improve the manual surgical planning procedures. The conventional architecture...

(This article belongs to the Special Issue Advancements in Cross-Disciplinary AI: Theory and Application, 3rd Edition)
  • Article
  • Open Access
35 Citations
6,454 Views
17 Pages

State Recognition of Bone Drilling Based on Acoustic Emission in Pedicle Screw Operation

  • Fengqing Guan,
  • Yu Sun,
  • Xiaozhi Qi,
  • Ying Hu and ,
  • Gang Yu and
  • Jianwei Zhang
  • + 1 author+ 0 author

9 May 2018

Pedicle drilling is an important step in pedicle screw fixation and the most significant challenge in this operation is how to determine a key point in the transition region between cancellous and inner cortical bone. The purpose of this paper is to...

(This article belongs to the Section Physical Sensors)
  • Article
  • Open Access
591 Views
20 Pages

18 March 2026

Background/Objectives: Accurate pedicle screw placement is critical in spine surgery, as malposition can cause neurological, vascular, or visceral injuries and compromise construct stability. The primary objective of this study was to develop and exp...

(This article belongs to the Special Issue Advances in Spine Surgery: Current Innovations and Future Directions)
  • Article
  • Open Access
2 Citations
5,552 Views
13 Pages

Reduction in Radiation Exposure in Minimally Invasive Pedicle Screw Placement Using a Tubular Retractor: A Pilot Study

  • Takeshi Oki,
  • Alan Kawarai Lefor,
  • Kentaro Nakamura,
  • Takahiro Higashi and
  • Isao Oki

20 December 2022

Background and Objectives: Percutaneous pedicle screw (PPS) placement is a minimally invasive spinal procedure that has been rapidly adopted over the last decade. However, PPS placement has elicited fear of increased radiation exposure from some surg...

(This article belongs to the Special Issue Radiation Protection Opportunities in Medical Imaging)
  • Article
  • Open Access
2,772 Views
19 Pages

This study aimed to develop a novel modular pedicle screw system incorporating an elliptical sleeve to conform the pedicle’s elliptical cross-section and enhance fixation strength with mechanical stability. The biomechanical evaluation was cond...

(This article belongs to the Special Issue Joint Biomechanics and Implant Design)
  • Technical Note
  • Open Access
2 Citations
2,055 Views
11 Pages

29 May 2025

Introduction: Robotic-assisted (RA) spine surgery enhances pedicle screw placement accuracy through real-time navigation and trajectory guidance. However, the absence of traditional direct haptic feedback by freehand instrumentation remains a concern...

(This article belongs to the Special Issue Advances in Spine Surgery: Best Practices and Future Directions)
  • Article
  • Open Access
507 Views
11 Pages

Machine-Learning-Based Prediction of Cervical Pedicle Screw Malposition from Clinical and Anatomical Features

  • Milan S. Vosko,
  • Stefan Aspalter,
  • Anja Blenk,
  • Petra Böhm and ,
  • Nico Stroh-Holly,
  • Andreas Gruber and
  • Wolfgang Senker
  • + 2 authors+ 0 author

31 July 2026

Background/Objectives: Cervical pedicle screw (CPS) placement provides superior biomechanical stability but remains technically demanding and associated with a risk of screw malposition. While recent advances in imaging and navigation have improved p...

(This article belongs to the Special Issue Spine Surgery: Current Challenges and Opportunities)
  • Article
  • Open Access
1 Citations
1,214 Views
18 Pages

Does Resistance Indicate Malposition? A Standardized Comparison of Pedicle Screw Placement

  • Sascha Kurz,
  • Benjamin Fischer,
  • Janine Schultze,
  • Florian Metzner and ,
  • Toni Wendler,
  • Christoph-Eckhard Heyde and
  • Stefan Schleifenbaum
  • + 2 authors+ 0 author

Pedicle screw malpositioning remains a frequent complication, with reported rates from 2% to 15%, often leading to revision surgeries. Analyzing mechanical resistance and torque encountered during screw insertion has been implicated as a promising ap...

(This article belongs to the Special Issue Spine Biomechanics)
  • Article
  • Open Access
7 Citations
9,558 Views
9 Pages

Cutting Flute and Thread Design on Self-Tapping Pedicle Screws Influence the Insertion Torque and Pullout Strength

  • Lien-Chen Wu,
  • Yueh-Ying Hsieh,
  • Fon-Yih Tsuang,
  • Yi-Jie Kuo and
  • Chang-Jung Chiang

13 February 2022

Self-tapping screws are commonly used in trauma and maxillofacial surgery and are increasingly used for pedicle screw insertions. In order to evaluate how the quantity and length of cutting flutes on self-tapping pedicle screws affect the insertion t...

(This article belongs to the Special Issue Applied Sciences in Orthopaedics)
  • Article
  • Open Access
4,478 Views
10 Pages

Application of a Novel Attachable Magnetic Nerve Stimulating Probe in Intraoperative Lumbar Pedicle Screw Placement: A Porcine Model Study

  • Tae Sik Goh,
  • Sung-Chan Shin,
  • Hyun-Keun Kwon,
  • Eui-Suk Sung and ,
  • Se Bin Jun,
  • Byung-Joo Lee and
  • Jung Sub Lee
  • + 2 authors+ 0 author

25 August 2021

Pedicle screw instrumentation is a fundamental technique in lumbar spine surgery. However, several complications could occur when placing a pedicle screw, the most serious being damage to the neural structures. We developed an attachable magnetic ner...

(This article belongs to the Special Issue Recent Developments and Emerging Trends in Biomechanics)
  • Article
  • Open Access
1,416 Views
14 Pages

Local Pedicled Flaps and Biological Implant Options for Patients Undergoing Proctectomy for Crohn’s Disease When an Omental Pedicle Flap Is Not Possible

  • Jacob Baxter,
  • Ian S. Reynolds,
  • Nho V. Tran,
  • David W. Larson and ,
  • Kellie L. Mathis and
  • Nicholas P. McKenna
  • + 1 author+ 0 author

26 June 2025

Background and Objectives: Perineal wound complications and pelvic fluid collections or abscesses following proctectomy for Crohn’s disease are a common cause of morbidity and might be mitigated by filling the pelvis and occluding the pelvic in...

(This article belongs to the Section Surgery)
  • Article
  • Open Access
4 Citations
5,345 Views
8 Pages

Respective Correction Rates of Lateral Lumbar Interbody Fusion and Percutaneous Pedicle Screw Fixation for Lumbar Degenerative Spondylolisthesis

  • Norihiro Isogai,
  • Kodai Yoshida,
  • Yuta Shiono,
  • Yutaka Sasao and ,
  • Haruki Funao and
  • Ken Ishii
  • + 1 author+ 0 author

23 January 2022

Background and Objectives: There are few reports describing the radiographic correction of vertebral slippage in lateral interbody fusion and percutaneous pedicle screw fixation for lumbar degenerative spondylolisthesis. [Objectives] We evaluated the...

(This article belongs to the Special Issue Minimally Invasive Spinal Treatment (MIST)—a New Concept in the Treatment of Spinal Diseases)
  • Systematic Review
  • Open Access
32 Citations
7,891 Views
9 Pages

Cervical Spine Pedicle Screw Accuracy in Fluoroscopic, Navigated and Template Guided Systems—A Systematic Review

  • Arin Mahmoud,
  • Kanatheepan Shanmuganathan,
  • Brett Rocos,
  • Fady Sedra and ,
  • Alexander Montgomery and
  • Syed Aftab
  • + 1 author+ 0 author

22 October 2021

Background: Pedicle screws provide excellent fixation for a wide range of indications. However, their adoption in the cervical spine has been slower than in the thoracic and lumbar spine, which is largely due to the smaller pedicle sizes and the prox...

  • Article
  • Open Access
1 Citations
1,146 Views
17 Pages

4 January 2026

Objective: Lumbar interbody fusion (LIF) is widely used to treat degenerative spinal disorders; however, both fixation strategies and interbody Cage designs still present biomechanical limitations. This study aimed to develop a posterior lumbar inter...

  • Case Report
  • Open Access
650 Views
6 Pages

Ossification of the vascular pedicle following fibula free flap (FFF) reconstruction is an uncommon and typically asymptomatic complication. Symptomatic cases requiring intervention are rare. We report a 29-year-old man with anterior maxillary osteos...

  • Article
  • Open Access
1 Citations
2,794 Views
11 Pages

Evaluation of Pedicle Screw Position on Computerized Tomography Using Three-Dimensional Reconstruction Software

  • Jiwon Park,
  • Jin S. Yeom,
  • Yeonho Kim,
  • Yoonjoong Hwang and ,
  • Namkug Kim and
  • Sang-Min Park
  • + 1 author+ 0 author

11 December 2024

Background and Objectives: Recent advances in intraoperative navigation systems have improved the accuracy of pedicle screw placement in spine surgery. However, many hospitals have limited access to these advanced technologies due to resource constra...

(This article belongs to the Section Orthopedics)
  • Article
  • Open Access
7 Citations
4,253 Views
11 Pages

17 August 2022

Background and Objectives: Navigated pedicle screw placement is becoming increasingly popular, as it has been shown to reduce the rate of screw misplacement. We present our intraoperative workflow and initial experience in terms of safety, efficiency...

(This article belongs to the Special Issue New Advance in Minimally Invasive Spine Surgery)
  • Article
  • Open Access
13 Citations
10,597 Views
11 Pages

12 April 2019

Although dual-threaded pedicle screws have been developed, the advantages over single-threaded screws remain controversial. We aimed to investigate the biomechanical performance of two types of dual-threaded pedicle screw by comparing their pullout s...

(This article belongs to the Special Issue Biomaterials and Biofabrication)
  • Article
  • Open Access
13 Citations
4,521 Views
15 Pages

Evaluation of an Injectable Biphasic Calcium Sulfate/Hydroxyapatite Cement for the Augmentation of Fenestrated Pedicle Screws in Osteoporotic Vertebrae: A Biomechanical Cadaver Study

  • Xinggui Tian,
  • Deepak B. Raina,
  • Corina Vater,
  • David Kilian and ,
  • Tilman Ahlfeld,
  • Ivan Platzek,
  • Ute Nimtschke,
  • Magnus Tägil,
  • Lars Lidgren and
  • Stefan Zwingenberger
  • + 9 authors+ 4 authors

Cement augmentation of pedicle screws is one of the most promising approaches to enhance the anchoring of screws in the osteoporotic spine. To date, there is no ideal cement for pedicle screw augmentation. The purpose of this study was to investigate...

(This article belongs to the Special Issue Active Biomedical Materials and Their Applications)
  • Case Report
  • Open Access
1,458 Views
10 Pages

Isolated Bilateral Pedicle Fractures of L5 Without Underlying Predisposing Factors: A Rare Case Report

  • Jongyun Kwon,
  • Seunghan Yu,
  • Sang Hoon Jeong,
  • Byung Chul Kim and ,
  • Hyuk Jin Choi and
  • Mahnjeong Ha
  • + 1 author+ 0 author

9 December 2025

We report a rare case of isolated bilateral pedicle fractures in the lumbar spine that occurred without any identifiable risk factors. Such fractures are uncommon, as they are typically accompanied by multiple other fractures. This type of fracture i...

(This article belongs to the Section Clinical Neurology)
  • Article
  • Open Access
11 Citations
3,394 Views
16 Pages

Oblique lumbar interbody fusion (OLIF) can be combined with different screw instrumentations. The standard screw instrumentation is bilateral pedicle screw fixation (BPSF). However, the operation is time consuming because a lateral recumbent position...

(This article belongs to the Special Issue Biomedical and Bioengineering Technology: Current Applications in Sports Monitoring and Health Care)
  • Article
  • Open Access
12 Citations
7,614 Views
16 Pages

10 November 2021

Cortical bone trajectory (CBT) is increasingly used in spinal surgery. Although there are many biomechanical studies, the biomechanical effect of CBT in combination with traditional pedicle screws is not detailed. Therefore, the purpose of this study...

(This article belongs to the Section Applied Biosciences and Bioengineering)
  • Article
  • Open Access
21 Citations
6,922 Views
16 Pages

Experimental Evaluation of Screw Pullout Force and Adjacent Bone Damage According to Pedicle Screw Design Parameters in Normal and Osteoporotic Bones

  • Eun Sun Lee,
  • Tae Sik Goh,
  • Jin-Young Heo,
  • Yoon-Jin Kim and ,
  • Sang-Eui Lee,
  • Yun Hak Kim and
  • Chi-Seung Lee
  • + 2 authors+ 0 author

11 February 2019

This paper proposes an optimum design of the pedicle screw with respect to bone density and variables of the screw design. First, pedicle screws are designed and manufactured with design variables including the core diameter and conical angle that af...

(This article belongs to the Section Materials Science and Engineering)
  • Article
  • Open Access
19 Citations
6,379 Views
12 Pages

4 April 2024

Background: In recent years, intraoperative computed tomography (CT) navigation has become widely used for the insertion of pedicle screws in spinal fusion surgery. However, conventional intraoperative CT navigation may be impaired by infrared interf...

(This article belongs to the Special Issue Clinical Advances in Minimally Invasive Spinal Treatment)
  • Review
  • Open Access
24 Citations
8,390 Views
10 Pages

The History and Development of the Percutaneous Pedicle Screw (PPS) System

  • Ken Ishii,
  • Haruki Funao,
  • Norihiro Isogai,
  • Takanori Saito and ,
  • Takeshi Arizono,
  • Masahiro Hoshino and
  • Koji Sato
  • + 2 authors+ 0 author

7 August 2022

Minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) using the SEXTANT® system (Medtronic) featured the first generation of commercially available percutaneous pedicle screw (PPS) system in 2001. The innovative system has since be...

(This article belongs to the Special Issue Minimally Invasive Spinal Treatment (MIST)—a New Concept in the Treatment of Spinal Diseases)
  • Article
  • Open Access
17 Citations
5,050 Views
17 Pages

Hybrid Spine Simulator Prototype for X-ray Free Pedicle Screws Fixation Training

  • Sara Condino,
  • Giuseppe Turini,
  • Virginia Mamone,
  • Paolo Domenico Parchi and
  • Vincenzo Ferrari

24 January 2021

Simulation for surgical training is increasingly being considered a valuable addition to traditional teaching methods. 3D-printed physical simulators can be used for preoperative planning and rehearsal in spine surgery to improve surgical workflows a...

(This article belongs to the Special Issue Serious Games and Mixed Reality Applications for Healthcare)
  • Article
  • Open Access
2 Citations
2,192 Views
11 Pages

Finite Element Analysis of Stress Distribution in Canine Lumbar Fractures with Different Pedicle Screw Insertion Angles

  • Ziyao Zhou,
  • Xiaogang Shi,
  • Jiahui Peng,
  • Xiaoxiao Zhou and ,
  • Liuqing Yang,
  • Zhijun Zhong,
  • Haifeng Liu,
  • Guangneng Peng,
  • Chengli Zheng and
  • Ming Zhang
  • + 5 authors+ 0 author

19 July 2025

Pedicle screw fixation is a critical technique for stabilizing lumbar fractures in canines, yet the biomechanical implications of insertion angles remain underexplored. This study aims to identify optimal screw trajectories by analyzing stress distri...

(This article belongs to the Special Issue Advanced Therapy in Companion Animals—2nd Edition)
  • Article
  • Open Access
4 Citations
1,951 Views
10 Pages

Does Malpositioning of Pedicle Screws Affect Biomechanical Stability in a Novel Quasistatic Test Setup?

  • Stefan Schleifenbaum,
  • Florian Metzner,
  • Janine Schultze,
  • Sascha Kurz and ,
  • Christoph-Eckhard Heyde and
  • Philipp Pieroh
  • + 1 author+ 0 author

Pedicle screw fixation is a common spinal surgery technique, but concerns remain about stability when screws are malpositioned. Traditional in vitro pull-out tests assess anchorage but lack physiological accuracy. This study examined the stability of...

(This article belongs to the Special Issue Spine Biomechanics)
  • Article
  • Open Access
13 Citations
4,185 Views
14 Pages

An Augmented Reality-Based Interaction Scheme for Robotic Pedicle Screw Placement

  • Viktor Vörös,
  • Ruixuan Li,
  • Ayoob Davoodi,
  • Gauthier Wybaillie and ,
  • Emmanuel Vander Poorten and
  • Kenan Niu
  • + 1 author+ 0 author

6 October 2022

Robot-assisted surgery is becoming popular in the operation room (OR) for, e.g., orthopedic surgery (among other surgeries). However, robotic executions related to surgical steps cannot simply rely on preoperative plans. Using pedicle screw placement...

(This article belongs to the Special Issue Medical Augmented Reality Summer School (MARSS) 2021: Selected Contributions)
  • Article
  • Open Access
2 Citations
1,085 Views
14 Pages

1 December 2025

Background/Objectives: Long-term bisphosphonate (BP) therapy is an effective treatment for osteoporosis but has been associated with rare complications such as atypical femoral fractures (AFFs). Emerging reports suggest that similar insufficiency fra...

(This article belongs to the Special Issue Clinical Advances in Orthopaedic Treatment of Lumbar and Spine Diseases: 2nd Edition)
  • Feature Paper
  • Article
  • Open Access
15 Citations
6,271 Views
14 Pages

Glissonean Pedicle Isolation Focusing on the Laennec’s Capsule for Minimally Invasive Anatomical Liver Resection

  • Mamoru Morimoto,
  • Yoichi Matsuo,
  • Keisuke Nonoyama,
  • Yuki Denda and ,
  • Hiromichi Murase,
  • Tomokatsu Kato,
  • Hiroyuki Imafuji,
  • Kenta Saito and
  • Shuji Takiguchi
  • + 4 authors+ 0 author

18 July 2023

Background: Inflow control is one of the most important procedures during anatomical liver resection (ALR), and Glissonean pedicle isolation (GPI) is one of the most efficacious methods used in laparoscopic anatomical liver resection (LALR). Recognit...

(This article belongs to the Section Methodology, Drug and Device Discovery)
  • Article
  • Open Access
13 Citations
6,138 Views
13 Pages

Investigation of Bone Growth in Additive-Manufactured Pedicle Screw Implant by Using Ti-6Al-4V and Bioactive Glass Powder Composite

  • Tu-Ngoc Lam,
  • Minh-Giam Trinh,
  • Chih-Chieh Huang,
  • Pei-Ching Kung and ,
  • Wei-Chin Huang,
  • Wei Chang,
  • Lia Amalia,
  • Hsu-Hsuan Chin,
  • Nien-Ti Tsou and
  • E-Wen Huang
  • + 10 authors+ 5 authors

9 October 2020

In this study, we optimized the geometry and composition of additive-manufactured pedicle screws. Metal powders of titanium-aluminum-vanadium (Ti-6Al-4V) were mixed with reactive glass-ceramic biomaterials of bioactive glass (BG) powders. To optimize...

(This article belongs to the Special Issue Nanomaterials for Tissue Engineering Applications)
  • Article
  • Open Access
3 Citations
3,312 Views
7 Pages

Blood Loss Following Open Posterior Spinal Fusion in Fractures: Cannulated vs. Solid Pedicle Screws

  • Pedram Rajabifard,
  • John Edward Cunningham,
  • Michael A. Johnson,
  • Henrik Constantin Bäcker and
  • Peter Turner

16 January 2023

We aim to delineate whether there is increased blood loss with the use of cannulated pedicle screws compared to solid pedicle screws in patients undergoing posterior spinal fusion. A single-centre retrospective case-control study was undertaken on pa...

(This article belongs to the Section Methodology, Drug and Device Discovery)

of 12