Skip to Content
You are currently on the new version of our website. Access the old version .

801 Results Found

  • Article
  • Open Access
10 Citations
3,156 Views
19 Pages

29 August 2022

To address the problems in the calibration of soil water content sensors, in this study, we designed a low-cost edge electromagnetic field induction (EEMFI) sensor for soil water content measurement and proposed a normalized calibration method to eli...

(This article belongs to the Special Issue Embedded System for Smart Sensors/Actuators and IoT Applications)
  • Article
  • Open Access
11 Citations
3,192 Views
17 Pages

A Novel Variable Selection Method Based on Binning-Normalized Mutual Information for Multivariate Calibration

  • Liang Zhong,
  • Ruiqi Huang,
  • Lele Gao,
  • Jianan Yue and ,
  • Bing Zhao,
  • Lei Nie,
  • Lian Li,
  • Aoli Wu,
  • Kefan Zhang and
  • Hengchang Zang
  • + 8 authors+ 3 authors

26 July 2023

Variable (wavelength) selection is essential in the multivariate analysis of near-infrared spectra to improve model performance and provide a more straightforward interpretation. This paper proposed a new variable selection method named binning-norma...

(This article belongs to the Topic Advances in Spectroscopic and Chromatographic Techniques)
  • Article
  • Open Access
20 Citations
5,410 Views
16 Pages

A Normal Sensor Calibration Method Based on an Extended Kalman Filter for Robotic Drilling

  • Dongdong Chen,
  • Peijiang Yuan,
  • Tianmiao Wang,
  • Ying Cai and
  • Haiyang Tang

16 October 2018

To enhance the perpendicularity accuracy in the robotic drilling system, a normal sensor calibration method is proposed to identify the errors of the zero point and laser beam direction of laser displacement sensors simultaneously. The procedure of n...

(This article belongs to the Section Physical Sensors)
  • Article
  • Open Access
1 Citations
2,131 Views
16 Pages

10 October 2024

In multi-source fusion deformation-monitoring methods that utilize fiber Bragg grating (FBG) data and other data types, the lack of FBG constraint points in edge regions often results in inaccuracies in fusion results, thereby impacting the overall d...

(This article belongs to the Topic Advance and Applications of Fiber Optic Measurement: 2nd Edition)
  • Article
  • Open Access
7 Citations
3,717 Views
24 Pages

4 February 2023

Laser displacement sensors are widely used in the aviation industry for the purpose of surface normal measurements. The measurement of a surface normal depends on prior knowledge of the poses and positions of the sensors, which are obtained through c...

(This article belongs to the Special Issue Advances in Optical Sensing, Instrumentation and Systems)
  • Article
  • Open Access
55 Citations
7,540 Views
16 Pages

2 July 2022

Many researchers have used machine learning models to control artificial hands, walking aids, assistance suits, etc., using the biological signal of electromyography (EMG). The use of such devices requires high classification accuracy. One method for...

(This article belongs to the Special Issue Electromyography (EMG) Signal Acquisition and Processing)
  • Article
  • Open Access
11 Citations
4,860 Views
15 Pages

18 July 2022

Sensor drift fault calibration is essential to maintain the operation of heating, ventilation and air conditioning systems (HVAC) in buildings. Bayesian inference (BI) is becoming more and more popular as a commonly used sensor fault calibration meth...

(This article belongs to the Section Fault Diagnosis & Sensors)
  • Article
  • Open Access
3 Citations
3,213 Views
21 Pages

Restoration and Calibration of Tilting Hyperspectral Super-Resolution Image

  • Xizhen Zhang,
  • Aiwu Zhang,
  • Mengnan Li,
  • Lulu Liu and
  • Xiaoyan Kang

15 August 2020

Tilting sampling is a novel sampling mode for achieving a higher resolution of hyperspectral imagery. However, most studies on the tilting image have only focused on a single band, which loses the features of hyperspectral imagery. This study focuses...

(This article belongs to the Special Issue Hyperspectral Imaging (HSI) Sensing and Analysis)
  • Technical Note
  • Open Access
3 Citations
4,194 Views
14 Pages

25 July 2022

The paper describes two simple methods allowing phase offsets to be aligned between radiators of transmitting and receiving antenna arrays in a collocated MIMO (Multiple Input Multiple Output) radar. One method uses normalization with averaging, whil...

(This article belongs to the Special Issue Recent Advances in Signal Processing and Radar for Remote Sensing)
  • Article
  • Open Access
240 Views
46 Pages

15 October 2026

Normalization narrows visual domain gaps but moves discriminative cues into its residual. Many normalization-residual decomposition methods for domain generalization (DG) and unsupervised domain adaptation (UDA) rely primarily on channel-wise modelin...

(This article belongs to the Section Artificial Intelligence)
  • Article
  • Open Access
17 Citations
5,202 Views
23 Pages

As low-cost sensors have become ubiquitous in air quality measurements, there is a need for more efficient calibration and quantification practices. Here, we deploy stationary low-cost monitors in Colorado and Southern California near oil and gas fac...

(This article belongs to the Section Air Quality)
  • Article
  • Open Access
51 Citations
7,818 Views
16 Pages

Simultaneous Calibration: A Joint Optimization Approach for Multiple Kinect and External Cameras

  • Yajie Liao,
  • Ying Sun,
  • Gongfa Li,
  • Jianyi Kong and ,
  • Guozhang Jiang,
  • Du Jiang,
  • Haibin Cai,
  • Zhaojie Ju,
  • Hui Yu and
  • Honghai Liu
  • + 5 authors+ 0 author

24 June 2017

Camera calibration is a crucial problem in many applications, such as 3D reconstruction, structure from motion, object tracking and face alignment. Numerous methods have been proposed to solve the above problem with good performance in the last few d...

(This article belongs to the Special Issue Imaging Depth Sensors—Sensors, Algorithms and Applications)
  • Article
  • Open Access
4 Citations
3,108 Views
15 Pages

27 April 2019

A Bayesian framework-based approach is proposed for the quantitative validation and calibration of the kriging metamodel established by simulation and experimental training samples of the injection mechanism in squeeze casting. The temperature data u...

  • Article
  • Open Access
8 Citations
4,258 Views
17 Pages

Comparative Analysis of Thrombin Calibration Algorithms and Correction for Thrombin-α2macroglobulin Activity

  • William C. Chang,
  • Joseph W. Jackson,
  • Kellie R. Machlus,
  • Alisa S. Wolberg and
  • Mikhail V. Ovanesov

24 September 2020

Background: The thrombin generation (TG) test is useful for characterizing global hemostasis potential, but fluorescence substrate artifacts, such as thrombin-α2macroglobulin (T-α2MG) signal, inner filter effect (IFE), substrate consumpti...

(This article belongs to the Special Issue Thrombosis, Blood Clotting and Vascular Biology)
  • Article
  • Open Access
7 Citations
4,220 Views
19 Pages

31 October 2018

This paper presents a stereo camera-based head-eye calibration method that aims to find the globally optimal transformation between a robot’s head and its eye. This method is highly intuitive and simple, so it can be used in a vision system for...

(This article belongs to the Section Physical Sensors)
  • Article
  • Open Access
847 Views
16 Pages

17 December 2025

On-field calibration for SINS often uses right hexahedron, but the influence of the structure errors, such as mutual position tolerances towards parallelism or the perpendicularity of two arbitrary planes of the hexahedron, on the calibration accurac...

(This article belongs to the Section Navigation and Positioning)
  • Article
  • Open Access
16 Citations
7,722 Views
19 Pages

12 June 2012

This paper presents an improved iterative nonlinear calibration method in the gravitational field for both low-grade and high-grade triaxial accelerometers. This calibration method assumes the probability density function of a Gaussian distribution f...

(This article belongs to the Section Physical Sensors)
  • Article
  • Open Access
12 Citations
4,704 Views
12 Pages

16 May 2019

Due to the strong absorption of water vapor at wavelengths of 1350–1420 nm and 1820–1940 nm, under normal atmospheric conditions, the actual digital number (DN) response curve of a hyperspectral imager deviates from the Gaussian shape, wh...

(This article belongs to the Special Issue Advanced Hyper-Spectral Imaging, Sounding and Applications from Space)
  • Article
  • Open Access
1 Citations
2,361 Views
17 Pages

Low-Complexity Online Calibration for Large-Scale Multi-Beam Antennas

  • Yujie Lin,
  • Chunyuan Hu,
  • Zhengyuan Shi,
  • Bizheng Liang and
  • Jianguo Li

High-throughput satellite communication based on large-scale multi-beam antennas is a promising technology for sixth-generation (6G) mobile networks. Conventional online calibration methods for large-scale antennas after satellite launch are restrict...

(This article belongs to the Section Microwave and Wireless Communications)
  • Article
  • Open Access
10 Citations
6,478 Views
17 Pages

The On-Orbit Non-Uniformity Correction Method with Modulated Internal Calibration Sources for Infrared Remote Sensing Systems

  • Yicheng Sheng,
  • Xiong Dun,
  • Weiqi Jin,
  • Feng Zhou and ,
  • Xia Wang,
  • Fengwen Mi and
  • Si Xiao
  • + 2 authors+ 0 author

25 May 2018

The scanning infrared focal plane array (IRFPA) suffers from stripe-like non-uniformity due to the usage of many detectors, especially when working with a large time scale. Typical calibration systems tend to block the sensor aperture and expose the...

(This article belongs to the Section Remote Sensing Image Processing)
  • Article
  • Open Access
23 Citations
7,047 Views
20 Pages

Automatic Extrinsic Calibration of 3D LIDAR and Multi-Cameras Based on Graph Optimization

  • Jinshun Ou,
  • Panling Huang,
  • Jun Zhou,
  • Yifan Zhao and
  • Lebin Lin

13 March 2022

In recent years, multi-sensor fusion technology has made enormous progress in 3D reconstruction, surveying and mapping, autonomous driving, and other related fields, and extrinsic calibration is a necessary condition for multi-sensor fusion applicati...

(This article belongs to the Section Optical Sensors)
  • Article
  • Open Access
5 Citations
2,291 Views
12 Pages

Concentration-Temporal Multilevel Calibration of Low-Cost PM2.5 Sensors

  • Rong-Fuh Day,
  • Peng-Yeng Yin,
  • Yuh-Chin T. Huang,
  • Cheng-Yi Wang and ,
  • Chih-Chun Tsai and
  • Cheng-Hsien Yu
  • + 1 author+ 0 author

12 August 2022

Ambient aerosols have a significant impact on plant species mortality, air pollution, and climate change. It is critical to monitor the concentrations of aerosols, especially particulate matter with an aerodynamic diameter ≤ 2.5 μm (PM2.5), whi...

(This article belongs to the Special Issue Sustainability and Artificial Intelligence)
  • Article
  • Open Access
588 Views
26 Pages

Clothing pressure is a critical design parameter in compression garments, yet its estimation in three-dimensional (3D) digital environments remains challenging because it depends on fabric mechanics, garment deformation, body geometry, and garment&nd...

  • Article
  • Open Access
279 Views
21 Pages

24 September 2026

The large-scale integration of renewable energy loads has made distribution network waveforms strongly non-stationary. In addition to conventional harmonics and voltage deviations, power quality events with highly random triggering and extremely shor...

(This article belongs to the Special Issue Advanced Technologies in Monitoring and Fault Diagnosis for Power Equipment)
  • Article
  • Open Access
46 Citations
9,925 Views
17 Pages

A Probabilistic Approach to Phosphorus Speciation of Soils Using P K-edge XANES Spectroscopy with Linear Combination Fitting

  • Jon Petter Gustafsson,
  • Sabina Braun,
  • J. R. Marius Tuyishime,
  • Gbotemi A. Adediran and ,
  • Ruben Warrinnier and
  • Dean Hesterberg
  • + 1 author+ 0 author

A common technique to quantitatively estimate P speciation in soil samples is to apply linear combination fitting (LCF) to normalized P K-edge X-ray absorption near-edge structure (XANES) spectra. Despite the rapid growth of such applications, the un...

(This article belongs to the Special Issue Using Synchrotron Radiation to Perform Phosphate Speciation in Soils)
  • Article
  • Open Access
23 Citations
9,263 Views
21 Pages

SLAM-Based Self-Calibration of a Binocular Stereo Vision Rig in Real-Time

  • Hesheng Yin,
  • Zhe Ma,
  • Ming Zhong,
  • Kuan Wu and ,
  • Yuteng Wei,
  • Junlong Guo and
  • Bo Huang
  • + 2 authors+ 0 author

22 January 2020

The calibration problem of binocular stereo vision rig is critical for its practical application. However, most existing calibration methods are based on manual off-line algorithms for specific reference targets or patterns. In this paper, we propose...

(This article belongs to the Special Issue Camera as a Smart-Sensor (CaaSS))
  • Article
  • Open Access
5 Citations
3,402 Views
10 Pages

Study on the CHZ-II Gravimeter and Its Calibrations along Forward and Reverse Overlapping Survey Lines

  • Haibo Tu,
  • Kun Liu,
  • Heng Sun,
  • Qian Cui and ,
  • Yuan Yuan,
  • Sunjun Liu,
  • Jiangang He and
  • Lintao Liu
  • + 3 authors+ 0 author

30 November 2022

The moving-base gravimeter is one of the key instruments used for Earth gravity survey. The accuracy of the survey data is closely related to the calibration precision of several key parameters, such as the damping delay time, the drift coefficient,...

(This article belongs to the Special Issue Accelerometer and Magnetometer: From Fundamentals to Applications)
  • Article
  • Open Access
1,122 Views
22 Pages

13 September 2025

Traditional calibration methods often assume constant parameters that remain unchanged across input conditions, which can limit predictive accuracy when parameters actually vary. To address this issue, we propose a novel calibration framework with ti...

(This article belongs to the Special Issue Parametric and Nonparametric Statistics: From Theory to Applications, 2nd Edition)
  • Article
  • Open Access
34 Citations
10,562 Views
13 Pages

Verification of Non-Invasive Blood Glucose Measurement Method Based on Pulse Wave Signal Detected by FBG Sensor System

  • Shintaro Kurasawa,
  • Shouhei Koyama,
  • Hiroaki Ishizawa,
  • Keisaku Fujimoto and
  • Shun Chino

23 November 2017

This paper describes and verifies a non-invasive blood glucose measurement method using a fiber Bragg grating (FBG) sensor system. The FBG sensor is installed on the radial artery, and the strain (pulse wave) that is propagated from the heartbeat is...

(This article belongs to the Special Issue Fiber Bragg Grating Based Sensors)
  • Article
  • Open Access
5 Citations
7,818 Views
22 Pages

24 June 2016

Since it is impossible for surveillance personnel to keep monitoring videos from a multiple camera-based surveillance system, an efficient technique is needed to help recognize important situations by retrieving the metadata of an object-of-interest....

(This article belongs to the Special Issue Advances in Multi-Sensor Information Fusion: Theory and Applications)
  • Article
  • Open Access
1 Citations
2,930 Views
19 Pages

31 May 2022

A novel space-borne SAR technique, azimuthal multi-angle observation (AMAO), has recently been proposed. It has highly flexible working modes and powerful capability of target information acquisition, but has challenges in achieving radiometric measu...

(This article belongs to the Special Issue Applications of Advanced Remote Sensing Technology for Sustainable Resource Exploration and Assessment)
  • Article
  • Open Access
1 Citations
1,285 Views
15 Pages

16 November 2025

Low-cost optical sensors for particulate matter (PM) monitoring, such as the SDS011, are widely used due to their affordability and ease of deployment. However, their accuracy strongly depends on aerosol properties and environmental conditions, neces...

(This article belongs to the Special Issue Advanced Sensing Techniques for Environmental and Energy Systems)
  • Article
  • Open Access
3 Citations
1,562 Views
15 Pages

Evaluation of Velocity Signals Measured by Laser in Hydrophone Calibration Based on a Normalized Dynamic Time-Warping Algorithm

  • Xiaowei Liu,
  • Haijiang Zhu,
  • Min Wang,
  • Ping Yang and ,
  • Ke Wang and
  • Longbiao He
  • + 1 author+ 0 author

Laser heterodyne interferometry plays a crucial role in measuring the velocity of water particles during the calibration of hydrophones with the optical method. The velocity of water particles acts as an indicator of acoustic-pressure variations and...

  • Article
  • Open Access
4 Citations
3,053 Views
12 Pages

31 October 2019

A tribotester with an integrated load sensor based on a strain gauge is typically used to measure the friction coefficient generated by the contact-related sliding motion of two objects. Since the friction coefficient is obtained by dividing the meas...

(This article belongs to the Section A: Physics)
  • Article
  • Open Access
12 Citations
3,574 Views
18 Pages

Novel Bayesian Inference-Based Approach for the Uncertainty Characterization of Zhang’s Camera Calibration Method

  • Ramón Gutiérrez-Moizant,
  • María Jesús L. Boada,
  • María Ramírez-Berasategui and
  • Abdulla Al-Kaff

15 September 2023

Camera calibration is necessary for many machine vision applications. The calibration methods are based on linear or non-linear optimization techniques that aim to find the best estimate of the camera parameters. One of the most commonly used methods...

(This article belongs to the Special Issue Advances in Optical Sensing, Instrumentation and Systems)
  • Communication
  • Open Access
4 Citations
4,079 Views
11 Pages

24 December 2021

Aerosol optical depth (AOD) is an important atmospheric correction parameter in remote sensing. In order to obtain AOD accurately, the surface-based automatic sun photometer needs to carry out calibration regularly. The normally used Langley method c...

(This article belongs to the Section Atmospheric Remote Sensing)
  • Article
  • Open Access
32 Citations
8,399 Views
21 Pages

1 March 2018

Relative radiometric calibration, or flat fielding, is indispensable for obtaining high-quality optical satellite imagery for sensors that have more than one detector per band. High-resolution optical push-broom sensors with thousands of detectors pe...

(This article belongs to the Special Issue Data Restoration and Denoising of Remote Sensing Data)
  • Article
  • Open Access
16 Citations
5,066 Views
17 Pages

Uncertainty of CERES-Maize Calibration under Different Irrigation Strategies Using PEST Optimization Algorithm

  • Quanxiao Fang,
  • L. Ma,
  • R. D. Harmel,
  • Q. Yu and ,
  • M. W. Sima,
  • P. N. S. Bartling,
  • R. W. Malone,
  • B. T. Nolan and
  • J. Doherty
  • + 4 authors+ 0 author

An important but rarely studied aspect of crop modeling is the uncertainty associated with model calibration and its effect on model prediction. Biomass and grain yield data from a four-year maize experiment (2008–2011) with six irrigation trea...

(This article belongs to the Special Issue Model Application for Sustainable Agricultural Water)
  • Proceeding Paper
  • Open Access
2 Citations
2,623 Views
8 Pages

This paper proposes a method for obtaining surface normal orientation and 3-D shape of plano-convex lens using refraction stereo. We show that two viewpoints are sufficient to solve this problem under the condition that the refractive index of the ob...

(This article belongs to the Proceedings of The 18th International Conference on Experimental Mechanics)
  • Article
  • Open Access
1 Citations
1,121 Views
27 Pages

Advanced Big Data Solutions for Detector Calibrations for High-Energy Physics

  • Abdulameer Nour Jalal,
  • Stefan Oniga and
  • Balazs Ujvari

This investigation examines the Dead Hot Map (DHM) method and timing calibration for Run 14 Au+Au collisions in the PHENIX experiment. The DHM method guarantees data integrity by identifying and omitting defective detector towers (nonfunctional, hot,...

  • Article
  • Open Access
11 Citations
2,870 Views
18 Pages

The Operational Inflight Radiometric Uniform Calibration of a Directional Polarimetric Camera

  • Feinan Chen,
  • Donggen Luo,
  • Shuang Li,
  • Benyong Yang and ,
  • Liang Sun,
  • Shule Ge and
  • Jin Hong
  • + 2 authors+ 0 author

24 September 2021

The directional polarimetric camera (DPC) on-board the GF-5A satellite is designed for atmospheric or water color detection, which requires high radiometric accuracy. Therefore, in-flight calibration is a prerequisite for its inversion application. F...

  • Article
  • Open Access
3 Citations
1,457 Views
14 Pages

17 November 2023

A radial basis function (RBF) neural network-based calibration data prediction model for clock testers is proposed to address the issues of fixed calibration cycles, low efficiency, and waste of electrical energy. This provides a new method for clock...

(This article belongs to the Section Computer Science & Engineering)
  • Article
  • Open Access
137 Views
35 Pages

Cost-Aware Conformal Learning for Reliable Accident Detection Under Exchangeability Violations

  • Ghulam Mustafa,
  • Zia Ul Rehman,
  • Muhammad Adnan Khan and
  • Byung-Seo Kim

11 November 2026

Conformal prediction can give an accident detector coverage guarantees on its confidence, but only when the calibration and test data are exchangeable. Accident image benchmarks break it: a hash audit of three benchmarks finds 9% to 59% of test image...

(This article belongs to the Section Sensing and Imaging)
  • Article
  • Open Access
1 Citations
477 Views
22 Pages

20 August 2026

To address the insufficient representation of fault characteristics in rotating machinery vibration signals, the sensitivity of conventional Transformers to variations in input response amplitudes, and the limited ability of fixed sequence embedding...

(This article belongs to the Special Issue Intelligent Sensors and Signal Processing in Industry—2nd Edition)
  • Article
  • Open Access
3,124 Views
12 Pages

A Self-Calibration of Capacitor Mismatch Error for Pipeline ADCs

  • Dong-Hwan Seo,
  • Sunghoon Cho,
  • Jung-Gyun Kim and
  • Byung-Geun Lee

14 November 2023

This study proposes self-calibration of capacitor mismatch errors for high-resolution pipeline analog-to-digital converters (ADCs). The proposed calibration circuit recursively amplifies the capacitor mismatch error by re-utilizing a multiplying digi...

(This article belongs to the Special Issue Advanced Circuits and Systems for Emerging Applications)
  • Article
  • Open Access
1 Citations
1,675 Views
30 Pages

Distributed Sensor Network Calibration Under Sensor Nonlinearities with Applications in Aerodynamic Pressure Sensing

  • Srdjan S. Stanković,
  • Miloš S. Stanković,
  • Mladen Veinović,
  • Ivana Jokić and
  • Miloš Frantlović

16 April 2025

The theoretical part of this paper is devoted to a class of distributed blind calibration algorithms for large sensor networks based on consensus. The basic blind calibration method starts from affine sensor models and calibration functions, aiming t...

(This article belongs to the Section Sensor Networks)
  • Article
  • Open Access
5 Citations
4,134 Views
20 Pages

Dynamic Calibration Method of Multichannel Amplitude and Phase Consistency in Meteor Radar

  • Yujian Jin,
  • Xiaolong Chen,
  • Songtao Huang,
  • Zhuo Chen and ,
  • Jing Li and
  • Wenhui Hao
  • + 1 author+ 0 author

18 January 2025

Meteor radar is a widely used technique for measuring wind in the mesosphere and lower thermosphere, with the key advantage of being unaffected by terrestrial weather conditions, thus enabling continuous operation. In all-sky interferometric meteor r...

(This article belongs to the Special Issue Processes and Effects of Atmospheric and Ionospheric Dynamics Based on Remote Sensing Observations)
  • Communication
  • Open Access
33 Citations
6,407 Views
9 Pages

Quantitative determination of multiple effective components in a given plant usually requires a very large amount of authentic natural products. In this study, we proposed a rapid and non-destructive method for the simultaneous determination of echin...

  • Article
  • Open Access
16 Citations
923 Views
13 Pages

4 October 2017

Although the 45-dots calibration routine of a previous study (Blignaut, 2016) provided very good accuracy, it requires intense mental effort and the routine proved to be unsuccessful for young children who struggle to maintain concentration. The cali...

  • Article
  • Open Access
13 Citations
3,217 Views
16 Pages

11 December 2024

To enhance the accuracy and reliability of the discrete element simulation software EDEM 2023 for pavement asphalt mixture simulation, three representative coarse aggregate particles were modeled in 3D using the SolidWorks 2018 software and imported...

of 17