Skip to Content

877 Results Found

  • Feature Paper
  • Article
  • Open Access
22 Citations
9,879 Views
14 Pages

Electrical Treeing in Cable Insulation under Different HVDC Operational Conditions

  • Mehrtash Azizian Fard,
  • Mohamed Emad Farrag,
  • Scott McMeekin and
  • Alistair Reid

12 September 2018

Electrical treeing (ET) can irreversibly deteriorate the insulation of polymeric power cables leading to a complete failure. This paper presents the results of an experimental investigation into the effects of unipolar and polarity reversing DC volta...

  • Article
  • Open Access
3 Citations
2,673 Views
12 Pages

Electrical Detection of Degradation in Specimens of HVDC Cable Insulation

  • Douglas Jutsell Nilsson,
  • Stanislaw M. Gubanski and
  • Yuriy V. Serdyuk

1 August 2020

One of the challenges in laboratory investigation of degradation and ageing of HVDC cable insulation is related to securing, or in other words, imitating the real service environment of the material specimens. So far, the published data refer to expe...

  • Article
  • Open Access
21 Citations
3,173 Views
14 Pages

Electrical Resistance Performance of Cable Accessory Interface Considering Thermal Effects

  • Kai Wu,
  • Tianfeng Zhang,
  • Wenxin Lin,
  • Shaolei Wu and ,
  • Yu Feng,
  • Xiangyu Zuo and
  • Yunxiao Zhang
  • + 2 authors+ 0 author

1 June 2023

Power cables are widely used in various fields of power transmission, and cable accessories are the weakest link in power cable systems due to their complex structure and multi-layer insulation coordination issues. This paper investigates the changes...

(This article belongs to the Section Electronic Materials)
  • Article
  • Open Access
22 Citations
6,005 Views
15 Pages

Electrical Treeing in Power Cable Insulation under Harmonics Superimposed on Unfiltered HVDC Voltages

  • Mehrtash Azizian Fard,
  • Mohamed Emad Farrag,
  • Alistair Reid and
  • Faris Al-Naemi

14 August 2019

Insulation degradation is an irreversible phenomenon that can potentially lead to failure of power cable systems. This paper describes the results of an experimental investigation into the influence of direct current (DC) superimposed with harmonic v...

(This article belongs to the Special Issue Diagnostics and Condition Monitoring Technologies for Assuring Asset Performances)
  • Review
  • Open Access
2 Citations
3,025 Views
28 Pages

Robotic Disassembly of Electrical Cable Connectors: A Critical Review

  • Matteo Dall’Olio,
  • Edoardo Ida’ and
  • Marco Carricato

13 March 2026

The rapid increase in the production of Waste Electrical and Electronic Equipment (WEEE) and batteries requires advanced automated disassembly solutions. While disassembly automation has progressed, the non-destructive removal of electrical cable con...

(This article belongs to the Section Industrial Robots and Automation)
  • Feature Paper
  • Article
  • Open Access
12 Citations
13,614 Views
13 Pages

Automation of Electrical Cable Harnesses Testing

  • Zhuming Bi,
  • Carlos Pomalaza-Ráez,
  • Dustin Hershberger,
  • Jeremy Dawson and ,
  • Andrew Lehman,
  • John Yurek and
  • Jared Ball
  • + 2 authors+ 0 author

21 December 2017

Traditional automated systems, such as industrial robots, are applied in well-structured environments, and many automated systems have a limited adaptability to deal with complexity and uncertainty; therefore, the applications of industrial robots in...

  • Article
  • Open Access
3 Citations
2,005 Views
12 Pages

RETRACTED: Power Cable Status Evaluation Method Based on Electrical Tree Growth and Data Association Rules

  • Leixiong Wang,
  • Bo Wang,
  • Hengrui Ma,
  • Jiaxing Zhang and ,
  • Yifan He,
  • Hongxia Wang and
  • Hanqi Zhang
  • + 2 authors+ 0 author

1 October 2023

The partial discharge (PD) analysis method has remained one of the key technologies for cable condition assessment to diagnose cable operation state. In this paper, two power cable status evaluation methods are proposed based on electrical tree growt...

(This article belongs to the Section Energy Systems)
  • Article
  • Open Access
12 Citations
4,471 Views
16 Pages

Locating Method for Electrical Tree Degradation in XLPE Cable Insulation Based on Broadband Impedance Spectrum

  • Tao Han,
  • Yufei Yao,
  • Qiang Li,
  • Youcong Huang and ,
  • Zhongnan Zheng and
  • Yu Gao
  • + 1 author+ 0 author

9 September 2022

Electrical treeing is one of the main causes of crosslinked polyethylene (XLPE) cable failure. The current methods for locating electrical trees are mainly based on the partial discharge (PD) signal. However, PD signals are easily attenuated in the l...

(This article belongs to the Special Issue Detection and Diagnosis of Polymer Composites for Electrical and Electronic Engineering Application)
  • Article
  • Open Access
9 Citations
2,120 Views
13 Pages

Enhanced Electrical Tree Resistance of Polypropylene Cable Insulation by Introducing β-Crystals

  • Zhuoran Yang,
  • Bin Tong,
  • Han Wang,
  • Peixuan Zhu and ,
  • Huanyu Rao and
  • Zhonglei Li
  • + 1 author+ 0 author

14 September 2024

Polypropylene (PP) is regarded as a recyclable material for high-voltage direct current (HVDC) cable insulation due to its high melting point and electrical resistivity. This work focuses on the effect of the β-nucleating agent content on the el...

(This article belongs to the Section F6: High Voltage)
  • Article
  • Open Access
3 Citations
2,899 Views
22 Pages

1 June 2023

Carbon-fiber-reinforced polymer (CFRP) is a type of composite material with many superior performances, such as high tensile strength, light weight, corrosion resistance, good fatigue, and creep performance. As a result, CFRP cables have great potent...

(This article belongs to the Special Issue Optical Fiber Sensor Technology for Structural Health Monitoring)
  • Article
  • Open Access
20 Citations
5,520 Views
22 Pages

27 November 2019

The most severe partial discharges and main insulation failures of 10 kV cross-linked polyethylene cables occur at the joint due to defects caused by various factors during the manufacturing and installation processes. The electric field distortion i...

(This article belongs to the Special Issue High Voltage Engineering and Applications)
  • Article
  • Open Access
6 Citations
2,921 Views
14 Pages

Effect of sPP Content on Electrical Tree Growth Characteristics in PP-Blended Cable Insulation

  • Shuofan Zhou,
  • Fan Yu,
  • Wei Yang,
  • Zhonglei Li and ,
  • Zhaoliang Xing,
  • Mingsheng Fan,
  • Tao Han and
  • Boxue Du
  • + 3 authors+ 0 author

26 November 2020

This paper aims at investigating the electrical tree characteristics of isotactic polypropylene (iPP)/syndiotactic polypropylene (sPP) blends for thermoplastic cable insulation. PP blended samples with sPP contents of 0, 5, 15, 30, and 45 wt% are pre...

(This article belongs to the Special Issue Polymer Blends: Processing, Morphology, and Properties)
  • Article
  • Open Access
10 Citations
3,232 Views
13 Pages

Direct Current Electrical Performances of Cable Accessory Insulation EPDM Modified by Grafting Polar-Group Compound

  • Zhong-Yuan Li,
  • Wei-Feng Sun,
  • Jian Zhang,
  • Jian-Quan Liang and ,
  • Lei Wang and
  • Ke-Xin Zhang
  • + 1 author+ 0 author

31 October 2022

In order to improve electrical matching between ethylene-propylene-diene misch-polymere (EPDM) reinforce insulation and crosslinked polyethylene (XLPE) main insulation in direct current (DC) cable accessories, the glyceryl monooleate (GMO) organic co...

(This article belongs to the Special Issue Electric Properties, Characterization, and Simulation of Polymer Composites)
  • Article
  • Open Access
14 Citations
4,014 Views
18 Pages

Thermal Characterization and Thermal Effect Assessment of Biofouling around a Dynamic Submarine Electrical Cable

  • Ziad Maksassi,
  • Bertrand Garnier,
  • Ahmed Ould El Moctar,
  • Franck Schoefs and
  • Emmanuel Schaeffer

23 April 2022

Wind energy is expected to play a significant role in meeting emission targets over the next 20 years. Offshore wind turbines in deep water (>150 m) must be developed due to resource quality, environmental, and activity constraints. Floating offsh...

  • Article
  • Open Access
33 Citations
6,402 Views
9 Pages

9 October 2018

There is a long-standing puzzle concerning whether polyethylene blends are a suitable substitution for cable-insulation-used crosslinking polyethylene (XLPE) especially at elevated temperatures. In this paper, we investigate temperature dependence of...

(This article belongs to the Special Issue Polymer Blends and Compatibilization 2018)
  • Article
  • Open Access
6 Citations
5,032 Views
14 Pages

7 November 2017

The main purpose of this paper is to evaluate electrical tree degradation for cross-linked polyethylene (XLPE) cable insulation for three difference models. In order to show the distribution characteristics using phase resolved partial discharge (PD)...

(This article belongs to the Section F: Electrical Engineering)
  • Article
  • Open Access
1 Citations
8,311 Views
16 Pages

A New Approach to the Assessment of the Reduction in Visibility Caused by Fires of Electrical Cables

  • Jozef Martinka,
  • Peter Rantuch,
  • Marek Rolinec,
  • Jiri Pokorny and ,
  • Karol Balog,
  • Petr Kucera,
  • Marek Rybakowski and
  • Janka Sulova
  • + 3 authors+ 0 author

9 July 2019

Electricity is the most important form of household energy and one of the most important forms of energy for industry and transport. Electrical distribution in construction and transport is almost exclusively implemented using electrical cables. One...

(This article belongs to the Special Issue Fire Safety 2019)
  • Article
  • Open Access
2 Citations
3,907 Views
11 Pages

Recovery of Mineral Oil from Underground Electrical Cables

  • Stefano Caimi,
  • Claudio Colombo,
  • Raffaele Ferrari,
  • Giuseppe Storti and
  • Massimo Morbidelli

To remove the mineral oil impregnating the insulating paper present in old, disconnected, underground electrical cables, which represents a threat to the environment, two approaches are investigated at laboratory (1 m) and pilot (10 m) scales. The fi...

  • Article
  • Open Access
13 Citations
4,166 Views
14 Pages

29 November 2019

The significant number of cables of different materials and construction used extensively in building objects increases their fire load and, therefore, strongly influences safety in the case of fire. The purpose of the study was to identify relevant...

(This article belongs to the Special Issue Selected Papers from ISCP 2019—XXIV International Symposium on Combustion Processes)
  • Article
  • Open Access
9 Citations
4,598 Views
12 Pages

Combustible Material Content vs. Fire Properties of Electric Cables

  • Katarzyna Kaczorek-Chrobak and
  • Jadwiga Fangrat

24 November 2020

The fire load of buildings is significantly increased by means of electric cables, usually creating a long combustible base for fire to spread and in this way decreasing the fire safety of buildings. The aim of the study was to evaluate a relationshi...

(This article belongs to the Special Issue DC and AC Insulated Power Cables and Hybrid Transmission Lines: Insights, Operating Experiences and New Challenges)
  • Article
  • Open Access
1 Citations
2,721 Views
28 Pages

Calculations of Electrical Parameters of Cables in Wide Frequency Range

  • Bingxin He,
  • Zheren Zhang,
  • Qixin Ye,
  • Zheng Xu and ,
  • Xiaoming Huang and
  • Liu Yang
  • + 1 author+ 0 author

The significant capacitive effects of cables can cause resonance stability issues, making it crucial to accurately model cables in the wide frequency range (up to several kilo-Hertz) where resonance typically occurs. To address the complexity and the...

(This article belongs to the Section Industrial Electronics)
  • Article
  • Open Access
1 Citations
1,929 Views
15 Pages

Determination of Tensile Characteristics and Electrical Resistance Variation of Cables Used for Charging Electric Vehicles

  • Elena Roxana Cosau,
  • Viorel Goanta,
  • Igor Blanari,
  • Layth Alkisswani and
  • Fayez Samara

12 May 2025

In this paper, the tensile behavior of the power cable used for charging electric machines was analyzed. It is known that such a cable, consisting of several conductors, polymeric sheaths and textile core wire, can be subjected to mechanical and ther...

(This article belongs to the Section Polymer Applications)
  • Article
  • Open Access
4 Citations
4,498 Views
19 Pages

15 August 2022

Following environmental concerns and the rapid digitalization of our society, we are currently experiencing an extensive electrification and industrial revolution. High numbers of electric machines thus need to be assembled for varying applications,...

(This article belongs to the Section Advanced Manufacturing)
  • Article
  • Open Access
8 Citations
1,907 Views
17 Pages

11 November 2024

Among national infrastructure facilities, electric power facilities are very important sites that must maintain their functions properly even during a natural disaster or during social crises. Therefore, seismic design is required when necessary for...

(This article belongs to the Section F1: Electrical Power System)
  • Article
  • Open Access
6 Citations
3,229 Views
19 Pages

Preliminary Multiphysics Modeling of Electric High-Voltage Cable of Offshore Wind-Farms

  • Fouad Ech-Cheikh,
  • Abdelghani Matine and
  • Monssef Drissi-Habti

29 August 2023

During manufacture, handling, transportation, installation and operation, mechanical overstress can affect the electrical and thermal properties of the conductor. As the wires in general are made of copper, which is a very plastically deforming mater...

(This article belongs to the Section A3: Wind, Wave and Tidal Energy)
  • Article
  • Open Access
21 Citations
8,062 Views
14 Pages

26 June 2022

This article presents the electric field distribution E and dielectric losses ΔPdiel. in the insulation system of high-voltage cables. Such a system consists of inner and outer semiconductor screens and XLPE insulation. The aim of this study wa...

(This article belongs to the Special Issue Advanced Research of High Voltage Insulation)
  • Article
  • Open Access
503 Views
13 Pages

Simulation Study on the Electric-Field Distortion Induced by Typical Assembly Defects in Cable Terminals

  • Xin Yu,
  • Qiyuan Ren,
  • Yinge Li,
  • Mingyuan Yang and ,
  • Shihu Yu and
  • Xuetong Zhao
  • + 1 author+ 0 author

2 July 2026

As a critical insulation component in cable systems, the cable terminal is susceptible to defects caused by human and environmental factors during manufacturing, installation, and service. Such defects may lead to local electric-field distortion and...

(This article belongs to the Special Issue Research on Power Transformers, Power Cable, High Voltage and Insulation Technology)
  • Article
  • Open Access
1 Citations
613 Views
16 Pages

Research on a Universal Analytical Thermal Circuit Model for Civil Electric Cables

  • Can Liu,
  • Kaiquan Mai,
  • Ningxia Yin,
  • Huanlao Liu and
  • Zhong Zheng

31 December 2025

The measured standard resistance at 20 °C (R20) is a critical indicator for evaluating the quality of electric cables. Utilizing a thermal circuit model allows for the rapid determination of R20. Focusing on civil electrical cables, this study co...

(This article belongs to the Section F: Electrical Engineering)
  • Article
  • Open Access
23 Citations
5,193 Views
10 Pages

Partial Discharge Detection and Defect Location Method in GIS Cable Terminal

  • Songyuan Li,
  • Pengxian Song,
  • Zhanpeng Wei,
  • Xu Li and ,
  • Qinghua Tang,
  • Zhengzheng Meng,
  • Ji Li,
  • Songtao Liu,
  • Yuhuai Wang and
  • Jin Li
  • + 5 authors+ 0 author

29 December 2022

The complex structure of gas-insulated switchgear (GIS) cable terminals leads to serious electric field concentration, which is a frequent fault position of a high-voltage cable system. At present, due to the differences in the frequency bands of sen...

(This article belongs to the Topic Condition Monitoring and Diagnostic Methods for Power Equipment in New Energy Power Systems)
  • Article
  • Open Access
36 Citations
5,488 Views
14 Pages

Interface Damages of Electrical Insulation in Factory Joints of High Voltage Submarine Cables

  • Zhen-Peng Zhang,
  • Chang-Ji Zheng,
  • Mei Zheng,
  • Hong Zhao and ,
  • Jian-Kang Zhao,
  • Wei-Feng Sun and
  • Jun-Qi Chen
  • + 2 authors+ 0 author

30 July 2020

As a key accessory of high-voltage (HV) insulated submarine cable, the factory joints of the cross-linked polyethylene (XLPE) represent an unpredictable uncertainty in cable-connecting fabrications by means of the extruded molding joint (EMJ) techniq...

(This article belongs to the Section F: Electrical Engineering)
  • Article
  • Open Access
16 Citations
2,695 Views
14 Pages

20 June 2024

For wide-body all-electric aircraft (AEA), a high-power-delivery, low-system-mass electric power system (EPS) necessitates advanced cable technologies. Increasing voltage levels enhances power density yet poses challenges in aircraft cable design, in...

(This article belongs to the Special Issue Reliability and Condition Monitoring of Electric Motors and Drives)
  • Article
  • Open Access
9 Citations
4,286 Views
23 Pages

Application Assessment of Electrical Cables during Smoldering and Flaming Combustion

  • Rafał Porowski,
  • Robert Kowalik,
  • Piotr Ramiączek,
  • Paulina Bąk-Patyna and ,
  • Paweł Stępień,
  • Maria Zielecka,
  • Tomasz Popielarczyk,
  • Agata Ludynia,
  • Angelika Chyb and
  • Jarosław Gawdzik
  • + 5 authors+ 0 author

15 March 2023

Electrical cables are a potential source of ignition and fire hazards in various types of buildings and industrial installations, as well as in all modes of transportation, including aircraft. Fires in buildings pose the greatest threat to human life...

  • Article
  • Open Access
381 Views
11 Pages

Gate-to-Gate Benchmarking of Electricity Use and Electricity-Related CO2 Emissions in Mechanical Cable Recycling: A Descriptive Industrial Case Report from Poland

  • Małgorzata Hordyńska,
  • Jerzy Łabaj,
  • Piotr Madej,
  • Monika Michalska and ,
  • Anna Stasiuk-Piekarska and
  • Jacek Zatoński
  • + 1 author+ 0 author

5 August 2026

Cable scrap is a high-grade secondary copper resource, but transparent plant-scale evidence on the operational energy and emissions performance of mechanical separation lines remains limited. This descriptive industrial case report presents a non-rep...

(This article belongs to the Special Issue Innovative Technology for Waste Recycling: Carbon Footprint Analysis and Resource Efficiency)
  • Article
  • Open Access
9 Citations
3,931 Views
19 Pages

Energy Recovery via Thermal Gasification from Waste Insulation Electrical Cables (WIEC)

  • Roberta Mota-Panizio,
  • Manuel Jesús Hermoso-Orzáez,
  • Luís Carmo-Calado,
  • Victor Arruda Ferraz de Campos and ,
  • José Luz Silveira,
  • Maria Margarida Gonçalves and
  • Paulo Brito
  • + 2 authors+ 0 author

20 November 2020

The recovery of noble metals from electrical wires and cables results in waste materials such as polyvinyl chloride (PVC) and polyethylene (PE), that is, waste insulation electrical cables (WIEC), which have been processed by gasification for energy...

(This article belongs to the Section Energy Science and Technology)
  • Article
  • Open Access
6 Citations
2,975 Views
15 Pages

Effect of Interface Defects on the Electric–Thermal–Stress Coupling Field Distribution of Cable Accessory Insulation

  • Xu Lu,
  • Ran Hu,
  • Kongying Guo,
  • Rui Lan and ,
  • Jie Tian,
  • Yanhui Wei and
  • Guochang Li
  • + 2 authors+ 0 author

8 September 2024

The combined insulation interface of a high-voltage cable and accessories is the weakest part of a cable system. In this paper, the parameters of the dielectric constant, thermal conductivity, and elastic modulus of cross-linked polyethylene (XLPE) a...

(This article belongs to the Topic Condition Monitoring and Diagnostic Methods for Power Equipment in New Energy Power Systems)
  • Article
  • Open Access
15 Citations
5,223 Views
14 Pages

Odor Recognition of Thermal Decomposition Products of Electric Cables Using Odor Sensing Arrays

  • Yuanchang Liu,
  • Shintaro Furuno,
  • Sosuke Akagawa,
  • Rui Yatabe and ,
  • Takeshi Onodera,
  • Nobuyuki Fujiwara,
  • Hidekazu Takeda,
  • Seiichi Uchida and
  • Kiyoshi Toko
  • + 4 authors+ 0 author

An odor sensing system with chemosensitive resistors was used to identify the gases generated from overheated cables to prevent fire. Three different electric cables for a distribution cabinet were used. The cables had an insulation layer made of pol...

(This article belongs to the Special Issue Bioinspired Chemical Sensors and Micro-Nano Devices)
  • Article
  • Open Access
57 Citations
10,947 Views
17 Pages

28 July 2014

An elasto-magnetic (EM) and magneto-electric (ME) effect based elasto-magneto-electric (EME) sensor has been proposed recently by the authors for stress monitoring of steel cables with obvious superiorities over traditional elasto-magnetic sensors....

(This article belongs to the Special Issue Electromagnetic Components of Mechatronics and Micro-Electro-Mechanical-Systems (MEMS) – Modeling and Design)
  • Article
  • Open Access
16 Citations
4,042 Views
15 Pages

Behavior of XLPE for HVDC Cables under Thermo-Electrical Stress: Experimental Study and Ageing Kinetics Proposal

  • Hanen Yahyaoui,
  • Jerome Castellon,
  • Serge Agnel,
  • Aurelien Hascoat and ,
  • Wilfried Frelin,
  • Christophe Moreau,
  • Pierre Hondaa,
  • Dominique le Roux,
  • Virginie Eriksson and
  • Carl Johan Andersson
  • + 5 authors+ 0 author

4 November 2021

The present work deals with the study of the electrical behavior of cross-linked polyethylene (XLPE) used for HVDC cable insulation. The aim is to better understand the influences of electrical and thermal stresses on the insulating material in order...

  • Article
  • Open Access
12 Citations
3,651 Views
19 Pages

3 April 2023

Detecting and locating faults in electrical cables has been a permanent concern regarding electrical power distribution systems. Over time, several techniques have been developed aiming to manage these faulty situations in an efficient way. These tec...

(This article belongs to the Topic Artificial Intelligence and Sustainable Energy Systems)
  • Article
  • Open Access
1 Citations
1,501 Views
17 Pages

Temperature Estimation Method on Optic–Electric Composite Submarine Power Cable Based on Optical Fiber Distributed Sensing

  • Chao Luo,
  • Zhitao Feng,
  • Yihua Zhu,
  • Yuyan Liu and ,
  • Yi Zhang,
  • Ying Zhou,
  • Muning Zhang and
  • Lijuan Zhao
  • + 3 authors+ 0 author

The status of an optic–electric composite high-voltage submarine cable (referred to as submarine cable) can be monitored based on optical fiber-distributed sensing technology, and at the same time, no additional sensor is needed in the monitori...

(This article belongs to the Special Issue Advances in Optical Fiber Sensing Technology)
  • Feature Paper
  • Article
  • Open Access
10 Citations
2,765 Views
17 Pages

22 September 2022

The space charge characteristics of cross-linked polyethylene (XLPE) can be improved to some extent by doping the appropriate amount of nano-MgO. In this study, in order to explore the influence of nano-MgO on the space charge and electric field dist...

(This article belongs to the Special Issue Design and Management on High Voltage Power Systems and Insulation Materials)
  • Article
  • Open Access
1 Citations
1,885 Views
15 Pages

Rigless Advancements: Enhancing Electric Submersible Pump Reliability Through Cable Deployment

  • Majid M. Rafie,
  • Tariq A. Almubarak,
  • Khaled M. Mutairi and
  • Mulad B. Winarno

12 November 2025

Electric Submersible Pumps (ESPs) are widely deployed in high-flowrate wells but are constrained by frequent failures and the need for rig-based interventions. This study presents the development and field validation of a rigless cable-deployed ESP (...

(This article belongs to the Section H1: Petroleum Engineering)
  • Article
  • Open Access
9 Citations
3,785 Views
19 Pages

3 November 2021

Evaluating environmental conditions that trigger fire-fighting equipment is one of the primary design tasks that have to be taken into account when engineering electrical systems supplying such devices. All of the solutions are aimed at, among others...

(This article belongs to the Special Issue Resilience, Modeling, and Control of Electrical Power Systems)
  • Article
  • Open Access
29 Citations
4,774 Views
18 Pages

Convolutional Neural Network-Based Pattern Recognition of Partial Discharge in High-Speed Electric-Multiple-Unit Cable Termination

  • Chuanming Sun,
  • Guangning Wu,
  • Guixiang Pan,
  • Tingyu Zhang and ,
  • Jiali Li,
  • Shibo Jiao,
  • Yong-Chao Liu,
  • Kui Chen,
  • Kai Liu and
  • Guoqiang Gao
  • + 6 authors+ 1 author

22 April 2024

Partial discharge detection is considered a crucial technique for evaluating insulation performance and identifying defect types in cable terminals of high-speed electric multiple units (EMUs). In this study, terminal samples exhibiting four typical...

(This article belongs to the Section Fault Diagnosis & Sensors)
  • Article
  • Open Access
27 Citations
4,713 Views
15 Pages

Electrical Characterization of a New Crosslinked Copolymer Blend for DC Cable Insulation

  • Sarath Kumara,
  • Xiangdong Xu,
  • Thomas Hammarström,
  • Yingwei Ouyang and ,
  • Amir Masoud Pourrahimi,
  • Christian Müller and
  • Yuriy V. Serdyuk
  • + 2 authors+ 0 author

19 March 2020

To design reliable high voltage cables, clean materials with superior insulating properties capable of operating at high electric field levels at elevated temperatures are required. This study aims at the electrical characterization of a byproduct-fr...

(This article belongs to the Special Issue Advances in Electric Insulating Materials for Components of Power System)
  • Article
  • Open Access
10 Citations
2,845 Views
15 Pages

Classification of Partial Discharge in Vehicle-Mounted Cable Termination of High-Speed Electric Multiple Unit: A Machine Learning-Based Approach

  • Yanhua Yang,
  • Jiali Li,
  • Zhenbao Chen,
  • Yong-Chao Liu and ,
  • Kui Chen,
  • Kai Liu,
  • Dong-Li Xin,
  • Guoqiang Gao and
  • Guangning Wu
  • + 4 authors+ 0 author

This paper presents a machine learning-based approach to identify and separate partial discharge (PD) and two typical pulse interference (PI) signals in the vehicle-mounted cable terminations of high-speed electric multiple units (EMUs). First, a tes...

(This article belongs to the Special Issue Digital Twins and Robust Design Optimization for Greener Manufacturing of Electrical Machines and Devices)
  • Article
  • Open Access
15 Citations
3,904 Views
13 Pages

3 March 2023

In this study, the quantum chemical method was used to investigate the microscopic characteristics of α-poly viny difluoride (PVDF) molecules under the influence of an electric field, and the impact of mechanical stress and electric field polarizatio...

(This article belongs to the Special Issue Durability and Degradation of Polymeric Materials II)
  • Review
  • Open Access
17 Citations
10,383 Views
32 Pages

13 October 2025

Electrical cable insulation, mainly composed of polymeric materials, progressively deteriorates under thermal, electrical, mechanical, and environmental stress factors. This degradation reduces dielectric strength, thermal stability, and mechanical i...

(This article belongs to the Special Issue Cable and Wire Fires)
  • Article
  • Open Access
23 Citations
3,947 Views
11 Pages

13 December 2019

In order to achieve high quality electrical materials for cable terminations, the crosslinked ethylene-propylene-diene monomer (EPDM) materials, with adequate breakdown strength, appropriately increased conductivity and are developed by employing aux...

(This article belongs to the Special Issue Polymeric Materials for Electrical Applications)
  • Article
  • Open Access
15 Citations
3,593 Views
15 Pages

22 December 2023

To achieve exceptional recyclable DC cable insulation material using thermoplastic polypropylene (PP), we have introduced the organic polar molecule styrene-maleic anhydride copolymer (SMA) into PP-based insulation materials following the principles...

of 18