Skip to Content
You are currently on the new version of our website. Access the old version .

302 Results Found

  • Review
  • Open Access
1,324 Views
23 Pages

Background/Objective: Accurate digital recording of implant position is essential for achieving passive fit and predictable outcomes in complete-arch implant-supported prostheses. However, complete-arch cases remain challenging because of increased i...

(This article belongs to the Special Issue Advances in Digital Prosthodontics: Innovations in CAD-CAM Technology and Material Science)
  • Article
  • Open Access
438 Views
12 Pages

Influence of Implant Spatial Configuration on the Trueness of Complete-Arch Digital Implant Impressions: An In Vitro Study

  • Bárbara Pamies-Jordana,
  • Santiago Costa-Palau,
  • Miguel Roig,
  • Josep Cabratosa-Termes and
  • Oscar Figueras-Alvarez

1 June 2026

Accurate complete-arch digital implant impressions remain challenging because cumulative image stitching distortion may increase across geometrically complex edentulous arches. This in vitro study evaluated the influence of implant spatial configurat...

(This article belongs to the Section Applied Dentistry and Oral Sciences)
  • Article
  • Open Access
7 Citations
2,567 Views
12 Pages

Effectiveness of an AI-Assisted Digital Workflow for Complete-Arch Implant Impressions: An In Vitro Comparative Study

  • Marco Tallarico,
  • Mohammad Qaddomi,
  • Elena De Rosa,
  • Carlotta Cacciò and ,
  • Silvio Mario Meloni,
  • Ieva Gendviliene,
  • Wael Att,
  • Rim Bourgi,
  • Aurea Maria Lumbau and
  • Gabriele Cervino
  • + 5 authors+ 0 author

9 October 2025

Background: The accuracy and consistency of complete-arch digital impressions are fundamental for long-term success of implant-supported rehabilitations. Recently, artificial intelligence (AI)-assisted tools, such as SmartX (Medit Link v3.4.2, MEDIT...

(This article belongs to the Special Issue Advancements and Implications of Digital Workflow Integration in Implant Dentistry)
  • Article
  • Open Access
6 Citations
5,059 Views
13 Pages

Clinical Reliability of Complete-Arch Fixed Prostheses Supported by Narrow-Diameter Implants to Support Complete-Arch Restorations

  • Claudia Lorenzi,
  • Fabrizio Lio,
  • Piero Papi,
  • Vincenzo Mazzetti and ,
  • Andrea Laureti and
  • Claudio Arcuri
  • + 1 author+ 0 author

30 December 2022

The aim of this study was to evaluate the clinical application of fixed screw-retained complete-arch rehabilitations supported by four narrow-diameter implants (NDIs). The records of patients treated with complete-arch prostheses screwed onto four ND...

(This article belongs to the Section Applied Biosciences and Bioengineering)
  • Article
  • Open Access
6 Citations
6,031 Views
13 Pages

Evaluation of Polymethyl Methacrylate as a Provisional Material in a Fully Digital Workflow for Immediate-Load Complete-Arch Implant-Supported Prostheses over Three Months

  • Luis Carlos Garza,
  • Eduardo Crooke,
  • Marta Vallés,
  • Joan Soliva and ,
  • Xavier Rodríguez,
  • Mariona Rodeja and
  • Miguel Roig
  • + 2 authors+ 0 author

26 January 2025

While complete-arch digital-implant-scanning protocols have been described, their clinical outcomes when using polymethyl methacrylate (PMMA) as a provisional material remain insufficiently substantiated. This clinical study aims to integrate digital...

(This article belongs to the Special Issue Biomaterials for Restorative Dentistry)
  • Article
  • Open Access
227 Views
17 Pages

Linear and Angular Deviations of Complete-Arch Digital Implant Impressions Using Three Scan Body Systems: An In Vitro Study

  • Igor Blivajs,
  • Igor Smojver,
  • Yuval Reiser,
  • Stella Jurić and ,
  • Ena Hadžović,
  • Ivica Pelivan and
  • Dragana Gabrić
  • + 2 authors+ 0 author

21 October 2026

Background: Scan body systems may affect the transfer of implant positions in complete-arch digital impressions. This in vitro study compared linear and angular deviations among three systems in a mandibular All-on-4 model. Methods: Ten repeated scan...

(This article belongs to the Special Issue The Digital Dentistry Revolution: Precision from Diagnosis to Delivery)
  • Systematic Review
  • Open Access
40 Citations
3,789 Views
13 Pages

Accuracy of Computer-Assisted Flapless Implant Placement by Means of Mucosa-Supported Templates in Complete-Arch Restorations: A Systematic Review

  • Paolo Carosi,
  • Claudia Lorenzi,
  • Fabrizio Lio,
  • Pierluigi Cardelli and ,
  • Alessandro Pinto,
  • Andrea Laureti and
  • Alessandro Pozzi
  • + 2 authors+ 0 author

16 February 2022

The aim of this study was to systematically review the current scientific literature regarding the accuracy of fully guided flapless implant positioning for complete-arch rehabilitations in edentulous patients and to assess if there was any statistic...

(This article belongs to the Section Biomaterials)
  • Article
  • Open Access
8 Citations
4,260 Views
13 Pages

18 May 2021

Purpose: The aim of this study was to present a new method to analyze the three-dimensional accuracy of complete-arch dental impressions and verify the reliability of the method. Additionally, the accuracies of conventional and intraoral digital impr...

(This article belongs to the Special Issue Clinical Applications for Dentistry and Oral Health)
  • Case Report
  • Open Access
1,523 Views
14 Pages

Conversion Techniques for Immediate-Loading Interim Implant-Supported Complete-Arch Fixed Dental Prostheses (ISCFDPs): Four Clinical Reports

  • Toshiki Nagai,
  • Chao-Chieh Yang,
  • Amal Al-Faraj,
  • Matthew G. Thompson and ,
  • Elizabeth Rubalcava,
  • Apisit Akarapattananukul and
  • Wei-Shao Lin
  • + 2 authors+ 0 author

8 June 2026

Background/Objectives: Immediate-loading interim implant-supported complete-arch fixed dental prostheses (ISCFDPs) are widely used for immediate loading in edentulous patients. Although traditional denture conversion techniques are well established,...

(This article belongs to the Special Issue Dental Disease Research in the USA)
  • Article
  • Open Access
10 Citations
2,771 Views
15 Pages

Comparison of the Surface Roughness of CAD/CAM Metal-Free Materials Used for Complete-Arch Implant-Supported Prostheses: An In Vitro Study

  • Nataly Mory,
  • Rocío Cascos,
  • Alicia Celemín-Viñuela,
  • Cristina Gómez-Polo and ,
  • Rubén Agustín-Panadero and
  • Miguel Gómez-Polo
  • + 1 author+ 0 author

13 November 2023

The roughness of the intra-oral surfaces significantly influences the initial adhesion and the retention of microorganisms. The aim of this study was to analyze the surface texture of four different CAD-CAM materials (two high-performance polymers an...

(This article belongs to the Special Issue Progress in Biomaterials and Technologies in Dentistry)
  • Article
  • Open Access

Effect of Scan Body Splinting on Geometric Scan-Body Measurements in Complete-Arch Digital Implant Impressions: An In Vitro Study

  • Georgia Vasileiadi,
  • Katia Sarafidou,
  • Evangelos Ximinis,
  • Theodora Slini and ,
  • Fotis Gogomitros,
  • Konstantinos Krommydas,
  • Olga Naka,
  • Alexandros Tsouknidas,
  • Maria Kokoti and
  • Athina Bakopoulou
  • + 5 authors+ 0 author

10 November 2026

Background/Objectives: This in vitro study evaluated the effect of PEEK scan body splinting on geometric scan-body measurements obtained from complete-arch digital implant scans using two intraoral scanners under two simulated clinical scenarios. Met...

(This article belongs to the Special Issue Advancements in Prosthetic Dentistry: Materials, Techniques, Ethics, and Sustainable Clinical Applications)
  • Article
  • Open Access
245 Views
27 Pages

23 October 2026

Accurate transfer of implant positions is critical for complete-arch implant-supported rehabilitations, yet intraoral scanning accuracy degrades over long edentulous spans, where errors accumulate. This in vitro study evaluated the trueness and preci...

(This article belongs to the Special Issue Application of Biomaterials and Techniques in Dental Surgical Treatment (2nd Edition))
  • Article
  • Open Access
39 Citations
5,605 Views
17 Pages

In Vivo Complete-Arch Implant Digital Impressions: Comparison of the Precision of Three Optical Impression Systems

  • Jaime Orejas-Perez,
  • Beatriz Gimenez-Gonzalez,
  • Ignacio Ortiz-Collado,
  • Israel J. Thuissard and
  • Andrea Santamaria-Laorden

(1) Multiple in vitro studies reported insufficient accuracy of intraoral scanners (IOSs) for complete-arch multiple implant impression. The aim of the study is to analyze the precision of three IOSs, PIC dental (Pic dental, Iditec North West SL), TR...

(This article belongs to the Special Issue Advances of Digital Dentistry and Prosthodontics)
  • Article
  • Open Access
41 Citations
4,251 Views
10 Pages

Influence of Implant Scanbody Wear on the Accuracy of Digital Impression for Complete-Arch: A Randomized In Vitro Trial

  • Lorenzo Arcuri,
  • Fabrizio Lio,
  • Veronica Campana,
  • Vincenzo Mazzetti and ,
  • Francesca Romana Federici,
  • Alessandra Nardi and
  • Massimo Galli
  • + 2 authors+ 0 author

25 January 2022

The aim of this study was to evaluate the influence of implant scanbody (ISB) wear on the accuracy of digital impression for complete-arch. A polymethylmethacrylate (PMMA) edentulous mandibular model with four internal hexagonal interlocking conical...

(This article belongs to the Section Biomaterials)
  • Article
  • Open Access
17 Citations
3,848 Views
7 Pages

Complete-Arch Accuracy of Four Intraoral Scanners: An In Vitro Study

  • Giordano Celeghin,
  • Giulio Franceschetti,
  • Nicola Mobilio,
  • Alberto Fasiol and ,
  • Santo Catapano,
  • Massimo Corsalini and
  • Francesco Grande
  • + 2 authors+ 0 author

The purpose of this study is to define the accuracy of four intraoral scanners (IOS) through the analysis of digital impressions of a complete dental arch model. Eight metal inserts were placed on the model as reference points and then it was scanned...

(This article belongs to the Collection Healthcare in Dentistry)
  • Technical Note
  • Open Access
1 Citations
1,070 Views
10 Pages

In this study, a fully digital workflow enabling the alignment of pre- and postoperative mandibular intraoral scans in complete-arch implant rehabilitation using intraosseous fiducial reference markers is presented. A prosthetically driven digital wo...

  • Article
  • Open Access
34 Citations
8,882 Views
11 Pages

20 December 2019

This study aims to evaluate the accuracy of five different intraoral scanners and two different laboratory scanners for a complete arch. A computer-aided design (CAD) reference model (CRM) was obtained using industrial scanners. A CAD test model (CTM...

(This article belongs to the Special Issue Applied Sciences in Dentistry)
  • Article
  • Open Access
4 Citations
1,934 Views
9 Pages

5 November 2024

Objective: This study aimed to examine contemporary results of the frozen elephant trunk (FET) procedure in an all-comers patient cohort. Methods: Between January 2017 and May 2024, a total of 132 consecutive patients with either aortic aneurysm (n =...

(This article belongs to the Section Vascular Medicine)
  • Article
  • Open Access
965 Views
14 Pages

20 September 2025

The aim of this laboratory study was to evaluate the fitting accuracy of complete-arch implant-supported fixed dental prostheses (ISFDPs) and the occurrence of possible constraint forces after ISFDP fixation using the All-on-four treatment concept. A...

(This article belongs to the Special Issue Novel Dental Materials Design and Application)
  • Article
  • Open Access
73 Citations
13,404 Views
9 Pages

Repeatability of Intraoral Scanners for Complete Arch Scan of Partially Edentulous Dentitions: An In Vitro Study

  • Jae-Hyun Lee,
  • Je-Hyeon Yun,
  • Jung-Suk Han,
  • In-Sung Luke Yeo and
  • Hyung-In Yoon

8 August 2019

Research on whether the number or location of missing teeth affects the accuracy of intraoral scanners in partial edentulous patients is scarce. This study aimed to evaluate the precision of complete-arch scan data of various partial edentulous arche...

(This article belongs to the Special Issue Advances in Digital Dentistry: From Data Acquisition to Data Production)
  • Review
  • Open Access
19 Citations
7,186 Views
12 Pages

Techniques to Improve the Accuracy of Intraoral Digital Impression in Complete Edentulous Arches: A Narrative Review

  • Andrea Leggeri,
  • Paolo Carosi,
  • Vincenzo Mazzetti,
  • Claudio Arcuri and
  • Claudia Lorenzi

13 June 2023

Complete edentulous arches have been considered as one of the main limitations of intraoral scanners (IOSs). In these clinical scenarios, the accuracy of IOSs can be reduced because of several anatomical factors. To overcome these limitations, some s...

(This article belongs to the Special Issue Development and Applications of Digital Dentistry)
  • Article
  • Open Access
246 Views
6 Pages

A Less Invasive Approach to Repair the Aortic Arch Using a “Partial or Complete Debranching” of the Supraaortic Vessels

  • Jürg Schmidli,
  • Dai-Do Do,
  • Jürgen Triller,
  • Iris Baumgartner and ,
  • Pascal Berdat,
  • Fritz Widmer,
  • Felix Mahler and
  • Thierry Carrel
  • + 3 authors+ 0 author
Cardiovasc. Med.2005, 8(3), 82;https://doi.org/10.4414/cvm.2005.01083 
(registering DOI)

30 March 2005

Surgical replacement of the aortic arch is an established procedure that requires cardiopulmonary bypass and deep hypothermic circulatory arrest. However, this approach is associated with major perioperative risks. These risks and the fact that thora...

  • Case Report
  • Open Access
1 Citations
4,183 Views
10 Pages

9 October 2023

The advent of osseointegration has offered a quantum shift in treatment planning patients with missing teeth. Patients with a terminal dentition or edentulous arch have become candidates for a fixed rehabilitation with immediate function. A striking...

(This article belongs to the Special Issue Current Issues in Oral Health)
  • Feature Paper
  • Article
  • Open Access
12 Citations
6,350 Views
14 Pages

In Vitro Trueness and Precision of Intraoral Scanners in a Four-Implant Complete-Arch Model

  • Dimitrios Spagopoulos,
  • George Kaisarlis,
  • Foteini Spagopoulou,
  • Demetrios J. Halazonetis and ,
  • Jan-Frederik Güth and
  • Efstratios Papazoglou
  • + 1 author+ 0 author

12 January 2023

(1) Background: New intraoral (IOS) and laboratory scanners appear in the market and their trueness and precision have not been compared. (2) Methods: Seven IOS and two laboratory scanners were used to scan a mandibular edentulous model with four par...

  • Review
  • Open Access
49 Citations
13,267 Views
12 Pages

The Success and Complications of Complete-Arch Implant-Supported Fixed Monolithic Zirconia Restorations: A Systematic Review

  • Ludovico Maria Vozzo,
  • Luís Azevedo,
  • Juliana Campos Hasse Fernandes,
  • Patrícia Fonseca and ,
  • Filipe Araújo,
  • Wendel Teixeira,
  • Gustavo Vicentis Oliveira Fernandes and
  • André Correia
  • + 3 authors+ 0 author

19 April 2023

In full-arch rehabilitation with implant-supported fixed prostheses, using monolithic zirconia seems to have several advantages regarding function and esthetics. However, the current scientific evidence is still limited. Thus, the aim of this investi...

(This article belongs to the Special Issue Novel Zirconia Materials Applied in Dental Prostheses)
  • Article
  • Open Access
11 Citations
7,989 Views
12 Pages

Comparative Analysis of Intraoral Scanner Accuracy in a Six-Implant Complete-Arch Model: An In Vitro Study

  • Francesco Ferrini,
  • Federica Mazzoleni,
  • Matteo Barbini,
  • Carlotta Coppo and ,
  • Giovanna Laura Di Domenico and
  • Enrico Felice Gherlone
  • + 1 author+ 0 author

22 April 2024

(1) Background: Since new intraoral scanner (IOS) versions are introduced to the market and software continues to advance, there is an ongoing need to assess the accuracy of newer IOS models. (2) Methods: Four types of IOSs and one laboratory scanner...

  • Article
  • Open Access
30 Citations
4,686 Views
12 Pages

Feasibility of Using a Prosthetic-Based Impression Template to Improve the Trueness and Precision of a Complete Arch Digital Impression on Four and Six Implants: An In Vitro Study

  • Marco Tallarico,
  • Aurea Immacolata Lumbau,
  • Roberto Scrascia,
  • Gianluca Demelas and ,
  • Franco Sanseverino,
  • Rocco Amarena and
  • Silvio Mario Meloni
  • + 2 authors+ 0 author

11 August 2020

Background: Intraoral scanners (IOSs) in implantology represent a viable approach for single teeth or partial arches. However, when used for complete edentulous arches or long-span edentulous areas, it has been demonstrated that there is a need for i...

(This article belongs to the Special Issue Dental Implants and Materials)
  • Technical Note
  • Open Access
8 Citations
8,282 Views
7 Pages

Full-Arch, Implant-Fixed Complete Dentures in Monolithic Zirconia and Titanium: A Digital Workflow to Maximize Cost Effectiveness

  • Gaetano Noè,
  • Andrea Toffoli,
  • Roberto Bonfiglioli,
  • Guido Maria Macaluso and
  • Edoardo Manfredi

12 February 2022

Different techniques can be used to design and manufacture a full-arch, implant-supported prosthesis, and different materials can be chosen for its production, each with its advantages and limitations. One of the possibilities provided by digital too...

(This article belongs to the Section Prosthodontics)
  • Article
  • Open Access
18 Citations
3,034 Views
12 Pages

Effect of Scanned Area and Operator on the Accuracy of Dentate Arch Scans with a Single Implant

  • Vinicius Rizzo Marques,
  • Gülce Çakmak,
  • Hakan Yilmaz,
  • Samir Abou-Ayash and ,
  • Mustafa Borga Donmez and
  • Burak Yilmaz
  • + 1 author+ 0 author

15 July 2022

Studies have shown the effect of the operator and scanned areas on the accuracy of single implant scans. However, the knowledge on the scan accuracy of the remaining dental arch during single implant scans, which may affect the occlusion, is limited....

(This article belongs to the Special Issue Current Trends and Future Directions in Prosthetic and Implant Dentistry in the Digital Era)
  • Article
  • Open Access
3 Citations
3,702 Views
7 Pages

Transversal Arch Clamping for Complete Resection of Aneurysms of the Distal Ascending Aorta without Open Anastomosis

  • Andreas Rukosujew,
  • Arash Motekallemi,
  • Konrad Wisniewski,
  • Raluca Weber and ,
  • Fernando De Torres-Alba,
  • Abdulhakim Ibrahim,
  • Raphael Weiss,
  • Sven Martens and
  • Angelo Maria Dell’Aquila
  • + 4 authors+ 0 author

10 May 2022

Background: The extent of aortic replacement for aneurysms of the distal ascending aorta remains controversial and opinions vary between standard cross-clamp resection and open hemiarch anastomosis in circulatory arrest and selective cerebral perfusi...

(This article belongs to the Special Issue Advances in the Management of Cardiovascular Disease)
  • Article
  • Open Access
6 Citations
2,961 Views
18 Pages

Optimal Cable Force Adjustment for Long-Span Concrete-Filled Steel Tube Arch Bridges: Real-Time Correction and Reliable Results

  • Mengsheng Yu,
  • Xinyu Yao,
  • Nianchun Deng,
  • Tianzhi Hao and ,
  • Longlin Wang and
  • Hua Wang
  • + 1 author+ 0 author

30 August 2023

For complex structures, the existing optimization method for suspender cable forces involves extensive matrix operations during the solution process, requiring high computational power and time. As a result, obtaining a more accurate solution becomes...

(This article belongs to the Special Issue Construction Process Monitoring and Structural Damage Identification for Buildings and Bridges)
  • Article
  • Open Access
1 Citations
1,625 Views
12 Pages

28 November 2025

Background and Objectives: This study aimed to investigate the effect of the intraoral scanner, scanning technique, and implant position on the trueness measured by linear and angular deviations. Materials and Methods: An edentulous maxillary model w...

(This article belongs to the Special Issue Advances in Dental Prosthetics)
  • Article
  • Open Access
9 Citations
4,468 Views
10 Pages

A One-Year, Multicenter, Retrospective Evaluation of Narrow and Low-Profile Abutments Used to Rehabilitate Complete Edentulous Lower Arches: The OT Bridge Concept

  • Marco Montanari,
  • Roberto Scrascia,
  • Gabriele Cervino,
  • Massimo Pasi and ,
  • Emiliano Ferrari,
  • Erta Xhanari,
  • Alba Koshovari and
  • Marco Tallarico
  • + 3 authors+ 0 author

1 December 2020

Purpose: To evaluate preliminary data on survival and success rates of immediately loaded, screw-retained, restorations delivered on lower arches using narrow and low-profile OT Equator abutments. Methods: This retrospective study analyzed data of pa...

  • Article
  • Open Access
66 Citations
7,057 Views
13 Pages

This in vitro study aimed to evaluate the 3D analysis for complete arch, half arch, and tooth preparation region by using four analysis software programs. The CAD reference model (CRM; N = 1 per region) and CAD test models (CTMs; N = 20 per software)...

(This article belongs to the Special Issue New Advances in Dentistry)
  • Article
  • Open Access
14 Citations
4,592 Views
19 Pages

30 October 2024

Background: In recent years, advancements in digital dentistry have provided new opportunities for more predictable and efficient treatment options, particularly in patients with failing dentition. This study aimed to evaluate the effectiveness and a...

(This article belongs to the Special Issue Advancements and Implications of Digital Workflow Integration in Implant Dentistry)
  • Article
  • Open Access
  • Best Paper Award
53 Citations
8,694 Views
10 Pages

The Effect of Scanning Strategy on Intraoral Scanner’s Accuracy

  • Nikolaos A. Gavounelis,
  • Chrysoula-Maria C. Gogola and
  • Demetrios J. Halazonetis

4 July 2022

The purpose of the present study was to examine the impact of scanning strategy on trueness and precision of the impression acquired from an intraoral scanner. Fifteen complete-arch, mandibular, post-orthodontic treatment casts were scanned with a la...

(This article belongs to the Section Digital Technologies)
  • Systematic Review
  • Open Access
57 Citations
9,403 Views
12 Pages

Accuracy of Intraoral Scanner for Recording Completely Edentulous Arches—A Systematic Review

  • Gunjan Srivastava,
  • Subrat Kumar Padhiary,
  • Neeta Mohanty,
  • Pedro Molinero-Mourelle and
  • Najla Chebib

18 October 2023

Scanning edentulous arches during complete denture fabrication is a crucial step; however, the quality of the resulting digital scan is still questionable. The purpose of this study is to systematically review studies (both clinical and in vitro) and...

  • Case Report
  • Open Access
16 Citations
3,313 Views
13 Pages

3D-Printed Overlay Template for Diagnosis and Planning Complete Arch Implant Prostheses

  • Francisco X. Azpiazu-Flores,
  • Damian J. Lee,
  • Carlos A. Jurado and
  • Hamid Nurrohman

Dental implants are a reliable alternative to treating edentulism. In clinical situations where the dentition has been severely affected by partial edentulism, advanced wear, or periodontal disease, establishing important occlusal elements such as th...

(This article belongs to the Special Issue Second Edition of Innovative Solutions for Oral Healthcare)
  • Case Report
  • Open Access
12 Citations
4,882 Views
22 Pages

Full-Arch Guided Restoration and Bone Regeneration: A Complete Digital Workflow Case Report

  • Claudia Todaro,
  • Michael Cerri,
  • Ruggero Rodriguez y Baena and
  • Saturnino Marco Lupi

Objective: complex rehabilitations present multiple difficulties, regarding both the planification of the surgery and the design of the prothesis. A digital approach can support the workflow, as well as the degree of intraoperative precision, and imp...

(This article belongs to the Special Issue Second Edition of Innovative Solutions for Oral Healthcare)
  • Review
  • Open Access
17 Citations
5,064 Views
13 Pages

15 June 2023

Background: This study aimed to evaluate survival rate, marginal bone levels, and full arch prosthetic success on short implants when placed in areas of severely resorbed and edentulous mandibles. Methods: This is a systematic review of all randomize...

(This article belongs to the Section Applied Biosciences and Bioengineering)
  • Article
  • Open Access
5 Citations
5,115 Views
19 Pages

18 April 2023

Because of their beautiful appearance, strong crossing ability, and reasonable stress performance, the application of tied steel box arch bridges is becoming more and more extensive. Bridge construction monitoring can control and adjust the deviation...

(This article belongs to the Section F: Engineering and Materials)
  • Review
  • Open Access
5 Citations
1,329 Views
24 Pages

Materials and Techniques for Splinting Scan Bodies: A Scoping Review

  • Aspasia Pachiou,
  • Ioulianos Rachiotis,
  • Alexis Ioannidis,
  • Pune N. Paqué and ,
  • Ronald E. Jung and
  • Christos Rahiotis
  • + 1 author+ 0 author

9 February 2026

Background: Digital implant impressions using intraoral scanners are increasingly adopted; however, their accuracy remains challenging in complete-arch and extended edentulous scenarios due to limited anatomical reference points and cumulative stitch...

(This article belongs to the Special Issue Advanced Dental Materials: From Design to Application, Third Edition)
  • Article
  • Open Access
13 Citations
4,102 Views
12 Pages

28 January 2023

Background. The inaccurate maxillomandibular relationship of virtual casts following alignment by the vestibular scan may result in intersection (intermesh penetration) between opposing dental arch surfaces. Intersection occurs at short interocclusal...

(This article belongs to the Topic Digital Dentistry)
  • Article
  • Open Access
271 Views
15 Pages

Effect of Remaining Teeth on Complete Arch Implant Scanning: An In Vitro Comparison of Interabutment Deviations in Two Digital Workflows

  • Lucas David Galvani,
  • Kathleen Lemos Soares,
  • Jailson Junior Rodrigues Oliveira,
  • Cristian Fernando Sanchez-Puetate and ,
  • Maria Luísa Leite,
  • Milton Carlos Kuga and
  • Luís Geraldo Vaz
  • + 2 authors+ 0 author

20 September 2026

This in vitro study evaluated whether the presence of four remaining teeth affected the reproduction of interabutment spatial relationships by two intraoral scanning systems. A single three-dimensionally printed maxillary master model containing four...

(This article belongs to the Special Issue Recent Advances in Digital Dentistry and Oral Implantology, 2nd Edition)
  • Article
  • Open Access
19 Citations
7,379 Views
11 Pages

Accuracy of Implant Level Intraoral Scanning and Photogrammetry Impression Techniques in a Complete Arch with Angled and Parallel Implants: An In Vitro Study

  • Hani Tohme,
  • Ghida Lawand,
  • Rita Eid,
  • Khaled E. Ahmed and ,
  • Ziad Salameh and
  • Joseph Makzoume
  • + 1 author+ 0 author

22 October 2021

(1) Background: Stereophotogrammetry has recently been investigated showing high accuracy in complete implant supported cases but has scarcely been investigated in cases of tilted implants. The aim of this in vitro study was to compare the accuracy o...

(This article belongs to the Special Issue New Techniques, Materials and Technologies in Dentistry)
  • Article
  • Open Access
19 Citations
8,345 Views
16 Pages

19 May 2022

Objective: Information about full-digital protocols for bite registration with intraoral scanners on multiple implants in the edentulous jaw is scarce. The purpose of this comparative in vivo study was to investigate the reliability and time efficien...

(This article belongs to the Section Dentistry, Oral Surgery and Oral Medicine)
  • Article
  • Open Access
7 Citations
2,909 Views
15 Pages

Development of Artificial Neural Network-Based Prediction Model for Evaluation of Maxillary Arch Growth in Children with Complete Unilateral Cleft Lip and Palate

  • Mohamed Zahoor Ul Huqh,
  • Johari Yap Abdullah,
  • Matheel AL-Rawas,
  • Adam Husein and ,
  • Wan Muhamad Amir W Ahmad,
  • Nafij Bin Jamayet,
  • Maya Genisa and
  • Mohd Rosli Bin Yahya
  • + 3 authors+ 0 author

22 September 2023

Introduction: Cleft lip and palate (CLP) are the most common congenital craniofacial deformities that can cause a variety of dental abnormalities in children. The purpose of this study was to predict the maxillary arch growth and to develop a neural...

(This article belongs to the Special Issue Artificial Intelligence in the Diagnostics of Dental Disease)
  • Article
  • Open Access
431 Views
14 Pages

Record Extent and Occlusal Support in Scan-Assisted Interocclusal Registration: A Three-Dimensional In Vitro Study

  • Ragai Edward Matta,
  • Paula Töpel,
  • Fabian Lotz,
  • Manfred Wichmann and
  • Johannes Matthias Ries

Scan-assisted interocclusal registration may vary with record extent and occlusal support. Using separately fabricated high-hardness vinyl polysiloxane (VPS) records, a fixed bilateral buccal intraoral scanner (IOS) acquisition protocol, optical refe...

(This article belongs to the Special Issue Advanced Restorative Dental Materials and Implant Technologies)
  • Article
  • Open Access
2 Citations
4,980 Views
24 Pages

Optimizing Digital Impressions in Edentulous Patients Through Reference Point-Enhanced Scanning: A Quantitative Assessment of Accuracy and Time Efficiency

  • Biagio Rapone,
  • Maurizio De Francesco,
  • Francesco Inchingolo,
  • Grazieli Dalmaschio and ,
  • Alberto Pispero,
  • Filippo Tomarelli,
  • Giuseppe Gariffo,
  • Tiziano Testori,
  • Gianluca Martino Tartaglia and
  • Elisabetta Ferrara
  • + 6 authors+ 1 author

Background: Digital impression techniques for edentulous patients present unique challenges due to the absence of stable anatomical landmarks and variable soft tissue morphology. While intraoral scanners have shown promising results in dentate patien...

(This article belongs to the Special Issue Advances in Digital Design for Dental and Maxillofacial Prosthodontics)
  • Article
  • Open Access
392 Views
11 Pages

In Vivo Comparison of the Trueness of Conventional and Digital Interocclusal Registration

  • Felix Förtsch,
  • Johannes Ries,
  • Tom Kasperlik,
  • Manfred Wichmann and
  • Ragai Edward Matta

The objective was to evaluate the trueness of interocclusal registration obtained with three intraoral scanning systems versus a conventional impression and bite registration in fully dentate patients. Twenty adults with complete dentitions and Angle...

(This article belongs to the Special Issue New Tools for Multidisciplinary Treatment in Dentistry, 2nd Edition)

of 7