Skip to Content

426 Results Found

  • Article
  • Open Access
59 Views
25 Pages

Assessment of Reflection-Mode Imaging Performance for Ultrasound Computed Tomography Using Tissue-Mimicking Phantoms

  • Zhaohui Liu,
  • Di Zhang,
  • Ming Yuchi,
  • Chenggang Zhu and ,
  • Wu Qiu,
  • Mingyue Ding and
  • Fengqi Niu
  • + 2 authors+ 0 author

Ultrasound computed tomography (USCT) has emerged as a promising multi-modal imaging technique, yet standardized phantoms for validating its reflection-mode performance remain lacking, hindering system calibration and cross-platform comparison. In th...

(This article belongs to the Section Biosignal Processing)
  • Article
  • Open Access
3 Citations
4,737 Views
16 Pages

The Use of Digital Coronary Phantoms for the Validation of Arterial Geometry Reconstruction and Computation of Virtual FFR

  • Giulia Pederzani,
  • Krzysztof Czechowicz,
  • Nada Ghorab,
  • Paul D. Morris and ,
  • Julian P. Gunn,
  • Andrew J. Narracott,
  • David Rodney Hose and
  • Ian Halliday
  • + 3 authors+ 0 author

11 June 2022

We present computational fluid dynamics (CFD) results of virtual fractional flow reserve (vFFR) calculations, performed on reconstructed arterial geometries derived from a digital phantom (DP). The latter provides a convenient and parsimonious descri...

(This article belongs to the Special Issue Cardiovascular Hemodynamics)
  • Article
  • Open Access
18 Citations
6,545 Views
26 Pages

23 June 2022

This paper improves the accuracy of quantification in the arterial diameter-dependent impedance variance by altering the electrode configuration. The finite element analysis was implemented with a 3D human wrist fragment using ANSYS Electronics Deskt...

(This article belongs to the Special Issue Electromagnetic Sensors for Biomedical Applications)
  • Article
  • Open Access
11 Citations
2,062 Views
20 Pages

Optimization of Fast Non-Local Means Noise Reduction Algorithm Parameter in Computed Tomographic Phantom Images Using 3D Printing Technology

  • Hajin Kim,
  • Sewon Lim,
  • Minji Park,
  • Kyuseok Kim and ,
  • Seong-Hyeon Kang and
  • Youngjin Lee
  • + 1 author+ 0 author

Noise in computed tomography (CT) is inevitably generated, which lowers the accuracy of disease diagnosis. The non-local means approach, a software technique for reducing noise, is widely used in medical imaging. In this study, we propose a noise red...

(This article belongs to the Special Issue Image Quality Assessment Methods in Radiography, Computed Tomography and Magnetic Resonance)
  • Article
  • Open Access
4 Citations
2,353 Views
11 Pages

Computed Tomography-Assisted Study of the Liquid Contrast Agent’s Spread in a Hydrogel Phantom of the Brain Tissue

  • Anastasia S. Vanina,
  • Alexander V. Sychev,
  • Anastasia I. Lavrova,
  • Pavel V. Gavrilov and ,
  • Polina L. Andropova,
  • Elena V. Grekhnyova,
  • Tatiana N. Kudryavtseva and
  • Eugene B. Postnikov
  • + 3 authors+ 0 author

26 May 2023

Studying transport processes in the brain’s extracellular space is a complicated problem when considering the brain’s tissue. Tests of corresponding physical and mathematical problems, as well as the need for materials with cheap but real...

(This article belongs to the Section Non-Newtonian and Complex Fluids)
  • Article
  • Open Access
1 Citations
657 Views
16 Pages

A Comprehensive Evaluation of 3D-Printed Breast Phantoms: Impacts of Printing Technology and STL Processing on Multimodal Fidelity

  • Nikolay Dukov,
  • Vencislav Nastev,
  • Viktoria Petkova,
  • Ivan Buliev and ,
  • Zhivko Bliznakov,
  • Valentina Dobreva and
  • Kristina Bliznakova
  • + 2 authors+ 0 author

Anthropomorphic breast phantoms are increasingly used for the development and evaluation of breast imaging technologies. The aim of this study is to evaluate the impacts of the material combination and stereolithography or Standard Tessellation Langu...

  • Article
  • Open Access
27 Citations
3,968 Views
14 Pages

23 October 2020

Although conventional denoising filters have been developed for noise reduction from digital images, these filters simultaneously cause blurring in the images. To address this problem, we proposed the fast non-local means (FNLM) denoising algorithm w...

(This article belongs to the Special Issue Image Processing Techniques for Biomedical Applications)
  • Feature Paper
  • Article
  • Open Access
9 Citations
3,403 Views
8 Pages

Diagnostic Performance and Radiation Dose of the EOS System to Image Enchondromatosis: A Phantom Study

  • Domenico Albano,
  • Alessandro Loria,
  • Cristiana Fanciullo,
  • Alberto Bruno and ,
  • Carmelo Messina,
  • Antonella del Vecchio and
  • Luca Maria Sconfienza
  • + 2 authors+ 0 author

15 December 2020

Background: Radiation doses and capability of EOS, conventional radiography (CR), and computed tomography (CT) to detect and measure enchondromas in a dedicated five-year-old anthropomorphic phantom were compared. Methods: To simulate enchondromas, m...

(This article belongs to the Special Issue Applications of Medical Physics)
  • Article
  • Open Access
10 Citations
3,700 Views
12 Pages

(1) Background: 3D printable materials with accurately defined iodine content enable the development and production of radiological phantoms that simulate human tissues, including lesions after contrast administration in medical imaging with X-rays....

(This article belongs to the Section Biomimetics of Materials and Structures)
  • Article
  • Open Access
3 Citations
4,865 Views
14 Pages

28 February 2024

Computed tomography (CT) is a rapid and precise medical imaging modality, but it poses the challenge of high radiation exposure to patients. To control this issue, stringent quality control (QC) evaluations are imperative for CT. One crucial aspect o...

  • Article
  • Open Access
1 Citations
1,567 Views
13 Pages

4 May 2025

Lung computed tomography (CT) images are widely used to diagnose chronic obstructive pulmonary disease (COPD) by evaluating signs of lung tissue destruction. Accurate diagnosis requires standardizing the CT numbers in lung CT images to distinguish be...

(This article belongs to the Section Biomedical Sensors)
  • Article
  • Open Access
1 Citations
1,879 Views
14 Pages

Customization of Computed Tomography Radio-Opacity in 3D-Printed Contrast-Injectable Tumor Phantoms

  • Yuktesh Kalidindi,
  • Aravinda Krishna Ganapathy,
  • Liam Cunningham,
  • Adriene Lovato and ,
  • Brian Albers,
  • Anup S. Shetty and
  • David H. Ballard
  • + 2 authors+ 0 author

31 July 2024

Medical Imaging Phantoms (MIPs) calibrate imaging devices, train medical professionals, and can help procedural planning. Traditional MIPs are costly and limited in customization. Additive manufacturing allows for customizable, patient-specific phant...

(This article belongs to the Special Issue Current Trends in Microfabrication Techniques for Lab-on-a-Chip and Biomedical Microdevices)
  • Article
  • Open Access
478 Views
13 Pages

Multidimensional Quality Evaluation of Imaging Performance for Musculoskeletal Ultrasound Computed Tomography System

  • Xiaoxue Bai,
  • Li Zhao,
  • Pan Zhou,
  • Ge Bai and ,
  • Longxin Xiao,
  • Jianan Chen,
  • Ye Yu,
  • Weicheng Yan and
  • Yang Xu
  • + 4 authors+ 0 author

Core parameters of the Musculoskeletal Ultrasound Computed Tomography System (MUCTS), such as spatial resolution, slice thickness, and three-dimensional reconstruction volume error, directly determine imaging performance and clinical diagnostic accur...

(This article belongs to the Special Issue Advances in Medical Ultrasound Tomography Technology and Applications)
  • Article
  • Open Access
6 Citations
3,805 Views
12 Pages

Spatial Distribution of Noise Reduction in Four Iterative Reconstruction Algorithms in CT—A Technical Evaluation

  • Anette Guleng,
  • Kirsten Bolstad,
  • Ingvild Dalehaug,
  • Silje Flatabø and ,
  • Daniel Aadnevik and
  • Helge E. S. Pettersen
  • + 1 author+ 0 author

Iterative reconstruction (IR) is a computed tomgraphy (CT) reconstruction algorithm aiming at improving image quality by reducing noise in the image. During this process, IR also changes the noise properties in the images. To assess how IR algorithms...

(This article belongs to the Section Medical Imaging and Theranostics)
  • Article
  • Open Access
2 Citations
1,393 Views
18 Pages

30 November 2025

Additive manufacturing (AM) has rapidly evolved due to its design flexibility, ability to enable personalized fabrication, and reduced material waste. In the medical field, fused filament fabrication (FFF) facilitates the production of individualized...

(This article belongs to the Section Polymer Processing and Engineering)
  • Article
  • Open Access
15 Citations
4,215 Views
13 Pages

Detectability and Volumetric Accuracy of Pulmonary Nodules in Low-Dose Photon-Counting Detector Computed Tomography: An Anthropomorphic Phantom Study

  • Joost F. Hop,
  • Anna N. H. Walstra,
  • Gert-Jan Pelgrim,
  • Xueqian Xie and ,
  • Noor A. Panneman,
  • Niels W. Schurink,
  • Sebastian Faby,
  • Marcel van Straten,
  • Geertruida H. de Bock and
  • Marcel J. W. Greuter
  • + 6 authors+ 1 author

15 November 2023

The aim of this phantom study was to assess the detectability and volumetric accuracy of pulmonary nodules on photon-counting detector CT (PCD-CT) at different low-dose levels compared to conventional energy-integrating detector CT (EID-CT). In-house...

(This article belongs to the Special Issue Advances in Cardiovascular and Pulmonary Imaging)
  • Article
  • Open Access
2 Citations
1,887 Views
18 Pages

Composite Contrast Enhancement of Hydrogel-Based Implants for Photon-Counting Computed Tomography Studies

  • Evgeniya V. Suslova,
  • Denis A. Shashurin,
  • Konstantin I. Maslakov,
  • Stepan Yu. Kupreenko and ,
  • Tatyana O. Luneva,
  • Oleg S. Medvedev and
  • Georgy A. Chelkov
  • + 2 authors+ 0 author

8 December 2024

Hydrogels have a wide range of medical applications, including use within implantable systems. However, when used in implants, their visibility under conventional medical imaging techniques is limited, creating safety risks for patients. In the curre...

(This article belongs to the Special Issue Advanced Hydrogels for Biomedical Applications)
  • Article
  • Open Access
16 Citations
8,637 Views
36 Pages

Brain Wearables: Validation Toolkit for Ear-Level EEG Sensors

  • Guilherme Correia,
  • Michael J. Crosse and
  • Alejandro Lopez Valdes

15 February 2024

EEG-enabled earbuds represent a promising frontier in brain activity monitoring beyond traditional laboratory testing. Their discrete form factor and proximity to the brain make them the ideal candidate for the first generation of discrete non-invasi...

(This article belongs to the Special Issue Biomedical Electronics and Wearable Systems)
  • Article
  • Open Access
7 Citations
4,879 Views
10 Pages

The purpose of this phantom study was to compare the accuracy, speed and technical performance of CT guided needle placement using a conventional technique versus a novel, gantry integrated laser guidance system for both an expert and a novice. A tot...

(This article belongs to the Section Medical Imaging and Theranostics)
  • Article
  • Open Access
3 Citations
3,322 Views
10 Pages

Robustness of Deep Learning Algorithm to Varying Imaging Conditions in Detecting Low Contrast Objects in Computed Tomography Phantom Images: In Comparison to 12 Radiologists

  • Hae Young Kim,
  • Kyeorye Lee,
  • Won Chang,
  • Youngjune Kim and ,
  • Sungsoo Lee,
  • Dong Yul Oh,
  • Leonard Sunwoo,
  • Yoon Jin Lee and
  • Young Hoon Kim
  • + 4 authors+ 0 author

28 February 2021

The performance of deep learning algorithm (DLA) to that of radiologists was compared in detecting low contrast objects in CT phantom images under various imaging conditions. For training, 10,000 images were created using American College of Radiolog...

(This article belongs to the Special Issue Deep Learning for Computer-Aided Diagnosis in Biomedical Imaging)
  • Article
  • Open Access
8 Citations
2,203 Views
36 Pages

No Reproducibility, No Progress: Rethinking CT Benchmarking

  • Dmitry Polevoy,
  • Danil Kazimirov,
  • Marat Gilmanov and
  • Dmitry Nikolaev

2 October 2025

Reproducibility is a cornerstone of scientific progress, yet in X-ray computed tomography (CT) reconstruction, it remains a critical and unresolved challenge. Current benchmarking practices in CT are hampered by the scarcity of openly available datas...

(This article belongs to the Special Issue Tools and Techniques for Improving Radiological Imaging Applications)
  • Article
  • Open Access
1,040 Views
16 Pages

Processing and Modeling of Alginate Hydrogel for Radiologically-Equivalent Biomedical Phantoms

  • Olusegun J. Ilegbusi,
  • Godson N. Brako,
  • Chiranjit Maiti and
  • Jihua Gou

23 April 2026

The foaming of hydrogels presents a promising strategy for tailoring mechanical and radiological properties to replicate biological soft tissues for biomedical phantom applications. A computational fluid dynamics (CFD) framework is developed to predi...

(This article belongs to the Special Issue Recent Research on Alginate Hydrogels in Bioengineering Applications (2nd Edition))
  • Article
  • Open Access
6 Citations
4,386 Views
9 Pages

Assessment of Fetal Dose and Health Effect to the Fetus from Breast Cancer Radiotherapy during Pregnancy

  • Pattarakan Suwanbut,
  • Thiansin Liamsuwan,
  • Danupon Nantajit,
  • Wilai Masa-nga and
  • Chirapha Tannanonta

7 January 2022

Decision for radiotherapy during the first trimester of pregnancy may occur, as patients may not realize their pregnancy at the very early stage. Since radiation dose can affect fetal development, the aim of this study was to evaluate fetal dose and...

(This article belongs to the Special Issue Ionizing Radiation: Health Effects, Radiological Protection and Medical Applications)
  • Article
  • Open Access
38 Citations
6,112 Views
15 Pages

Performance of Spectral Photon-Counting Coronary CT Angiography and Comparison with Energy-Integrating-Detector CT: Objective Assessment with Model Observer

  • David C. Rotzinger,
  • Damien Racine,
  • Fabio Becce,
  • Elias Lahoud and ,
  • Klaus Erhard,
  • Salim A. Si-Mohamed,
  • Joël Greffier,
  • Anaïs Viry,
  • Loïc Boussel and
  • Philippe C. Douek
  • + 8 authors+ 3 authors

16 December 2021

Aims: To evaluate spectral photon-counting CT’s (SPCCT) objective image quality characteristics in vitro, compared with standard-of-care energy-integrating-detector (EID) CT. Methods: We scanned a thorax phantom with a coronary artery module at...

(This article belongs to the Special Issue Advances in Photon Counting Detector Imaging)
  • Article
  • Open Access
34 Citations
4,214 Views
9 Pages

Dose Reduction in Coronary Artery Calcium Scoring Using Mono-Energetic Images from Reduced Tube Voltage Dual-Source Photon-Counting CT Data: A Dynamic Phantom Study

  • Niels R. van der Werf,
  • Margo van Gent,
  • Ronald Booij,
  • Daniel Bos and ,
  • Aad van der Lugt,
  • Ricardo P. J. Budde,
  • Marcel J. W. Greuter and
  • Marcel van Straten
  • + 3 authors+ 0 author

25 November 2021

In order to assess coronary artery calcium (CAC) quantification reproducibility for photon-counting computed tomography (PCCT) at reduced tube potential, an anthropomorphic thorax phantom with low-, medium-, and high-density CAC inserts was scanned w...

(This article belongs to the Special Issue Advances in Photon Counting Detector Imaging)
  • Article
  • Open Access
46 Citations
9,265 Views
21 Pages

Multimodal Breast Phantoms for Microwave, Ultrasound, Mammography, Magnetic Resonance and Computed Tomography Imaging

  • Giuseppe Ruvio,
  • Raffaele Solimene,
  • Antonio Cuccaro,
  • Gaia Fiaschetti and ,
  • Andrew J. Fagan,
  • Sean Cournane,
  • Jennie Cooke,
  • Max J. Ammann,
  • Jorge Tobon and
  • Jacinta E. Browne
  • + 5 authors+ 0 author

23 April 2020

The aim of this work was to develop multimodal anthropomorphic breast phantoms suitable for evaluating the imaging performance of a recently-introduced Microwave Imaging (MWI) technique in comparison to the established diagnostic imaging modalities o...

(This article belongs to the Special Issue Measurements Techniques of Biological Tissues Dielectric Properties, Updated Data and Current Applications)
  • Data Descriptor
  • Open Access
5 Citations
3,574 Views
10 Pages

16 August 2022

The World Health Organization indicates the top cause of death is heart disease. These diseases can be detected using several imaging modalities, especially cardiac computed tomography (CT), whose images have imperfections associated with noise and c...

(This article belongs to the Topic Complex Data Analytics and Computing with Real-World Applications)
  • Article
  • Open Access
10 Citations
3,004 Views
11 Pages

Computed Tomography Attenuation of Three-Dimensional (3D) Printing Materials—Depository to Aid in Constructing 3D-Printed Phantoms

  • Yuktesh Kalidindi,
  • Aravinda Krishna Ganapathy,
  • Yash Nayak,
  • Anusha Elumalai and ,
  • David Z. Chen,
  • Grace Bishop,
  • Adrian Sanchez,
  • Brian Albers,
  • Anup S. Shetty and
  • David H. Ballard
  • + 5 authors+ 0 author

14 October 2023

Three-dimensionally printed phantoms are increasingly used in medical imaging and research due to their cost-effectiveness and customizability, offering valuable alternatives to commercial phantoms. The purpose of this study was to assess the compute...

(This article belongs to the Section B2: Biofabrication and Tissue Engineering)
  • Article
  • Open Access
16 Citations
4,837 Views
20 Pages

Characterization of Commercial and Custom-Made Printing Filament Materials for Computed Tomography Imaging of Radiological Phantoms

  • Filippos Okkalidis,
  • Chrysoula Chatzigeorgiou,
  • Nikiforos Okkalidis,
  • Nikolay Dukov and ,
  • Minko Milev,
  • Zhivko Bliznakov,
  • Giovanni Mettivier,
  • Paolo Russo and
  • Kristina Bliznakova
  • + 4 authors+ 0 author

In recent years, material extrusion-based additive manufacturing, particularly fused filament fabrication (FFF), has gained significant attention due to its versatility and cost-effectiveness in producing complex geometries. This paper presents the c...

(This article belongs to the Special Issue 3D Printing Technologies II)
  • Article
  • Open Access
9 Citations
5,055 Views
24 Pages

31 December 2024

This study aimed to 3D print a patient-specific chest phantom simulating multiple lung nodules to optimise low-dose Computed Tomography (CT) protocols for lung cancer screening. The chest phantom, which was developed from a single patient’s che...

(This article belongs to the Special Issue 3D Printing Technologies and Additive Manufacturing: Recent Advances and Applications)
  • Article
  • Open Access
63 Citations
6,892 Views
10 Pages

22 January 2019

A low-cost Photoacoustic Computed Tomography (PACT) system consisting of 16 single-element transducers has been developed. Our design proposes a fast rotating mechanism of 360° rotation around the imaging target, generating comparable images to t...

(This article belongs to the Special Issue Photoacoustic Tomography (PAT))
  • Article
  • Open Access
3 Citations
1,720 Views
21 Pages

The Impact of Weighting Factors on Dual-Energy Computed Tomography Image Quality in Non-Contrast Head Examinations: Phantom and Patient Study

  • Doris Šegota Ritoša,
  • Doris Dodig,
  • Slavica Kovačić,
  • Nina Bartolović and ,
  • Ivan Brumini,
  • Petra Valković Zujić,
  • Slaven Jurković and
  • Damir Miletić
  • + 3 authors+ 0 author

Background: This study aims to evaluate the impact of various weighting factors (WFs) on the quality of weighted average (WA) dual-energy computed tomography (DECT) non-contrast brain images and to determine the optimal WF value. Because they simulat...

(This article belongs to the Special Issue Computed Tomography Imaging in Medical Diagnosis, 2nd Edition)
  • Article
  • Open Access
2 Citations
1,997 Views
15 Pages

24 November 2024

Computed tomography (CT) imaging using low-dose radiation effectively reduces radiation exposure; however, it introduces noise amplification in the resulting image. This study models an adaptive nonlocal total variation (NL-TV) algorithm that efficie...

(This article belongs to the Special Issue Advances and Applications of Medical Imaging Physics)
  • Article
  • Open Access
10 Citations
8,793 Views
16 Pages

The Dose Optimization and Evaluation of Image Quality in the Adult Brain Protocols of Multi-Slice Computed Tomography: A Phantom Study

  • Thawatchai Prabsattroo,
  • Kanokpat Wachirasirikul,
  • Prasit Tansangworn,
  • Puengjai Punikhom and
  • Waraporn Sudchai

28 November 2023

Computed tomography examinations have caused high radiation doses for patients, especially for CT scans of the brain. This study aimed to optimize the radiation dose and image quality in adult brain CT protocols. Images were acquired using a Catphan...

(This article belongs to the Section Medical Imaging)
  • Article
  • Open Access
48 Citations
8,241 Views
32 Pages

Lung Nodule Segmentation with a Region-Based Fast Marching Method

  • Marko Savic,
  • Yanhe Ma,
  • Giovanni Ramponi,
  • Weiwei Du and
  • Yahui Peng

9 March 2021

When dealing with computed tomography volume data, the accurate segmentation of lung nodules is of great importance to lung cancer analysis and diagnosis, being a vital part of computer-aided diagnosis systems. However, due to the variety of lung nod...

(This article belongs to the Collection Sensors, Image, and Signal Processing for Biomedical Applications)
  • Article
  • Open Access
56 Citations
5,903 Views
15 Pages

Stability of Radiomic Features across Different Region of Interest Sizes—A CT and MR Phantom Study

  • Laura J. Jensen,
  • Damon Kim,
  • Thomas Elgeti,
  • Ingo G. Steffen and ,
  • Bernd Hamm and
  • Sebastian N. Nagel
  • + 1 author+ 0 author

8 June 2021

We aimed to evaluate radiomic features’ stability across different region of interest (ROI) sizes in CT and MR images. We chose a phantom with a homogenous internal structure so no differences for a feature extracted from ROIs of different sizes woul...

  • Article
  • Open Access
4 Citations
2,896 Views
12 Pages

17 September 2023

Background and Objectives: We attempted to determine the optimal radiation dose to maintain image quality using a deep learning application in a physical human phantom. Materials and Methods: Three 5 × 5 × 5 mm3 uric acid stones were plac...

(This article belongs to the Section Urology & Nephrology)
  • Article
  • Open Access
8 Citations
3,280 Views
17 Pages

6 January 2024

The aim of this study is to introduce a new filament and novel 3D printing technique to adjust the density of a printing job in order to mimic the radiological properties of different tissues. We used a special filament, Light Weight PLA (LW-PLA), wh...

(This article belongs to the Special Issue Advances in Diagnostic and Therapeutic Radiology — 2nd Edition)
  • Article
  • Open Access
13 Citations
4,136 Views
13 Pages

16 April 2024

Additive manufacturing and 3D printing allow for the design and rapid production of radiographic phantoms for X-ray imaging, including CT. These are used for numerous purposes, such as patient simulation, optimization of imaging procedures and dose l...

(This article belongs to the Special Issue Advance in 3D/4D Printing of Polymeric Materials)
  • Article
  • Open Access
84 Citations
6,475 Views
13 Pages

Quantum Iterative Reconstruction for Low-Dose Ultra-High-Resolution Photon-Counting Detector CT of the Lung

  • Thomas Sartoretti,
  • Damien Racine,
  • Victor Mergen,
  • Lisa Jungblut and ,
  • Pascal Monnin,
  • Thomas G. Flohr,
  • Katharina Martini,
  • Thomas Frauenfelder,
  • Hatem Alkadhi and
  • André Euler
  • + 5 authors+ 0 author

18 February 2022

The aim of this study was to characterize image quality and to determine the optimal strength levels of a novel iterative reconstruction algorithm (quantum iterative reconstruction, QIR) for low-dose, ultra-high-resolution (UHR) photon-counting detec...

(This article belongs to the Special Issue Advances in Photon Counting Detector Imaging)
  • Article
  • Open Access
4 Citations
2,469 Views
17 Pages

Background: Optimization of pulmonary nodule detection across varied imaging protocols remains challenging. We evaluated four DL-CAD systems and manual reading with volume rendering (VR) for performance under varying radiation doses and reconstructio...

(This article belongs to the Section Machine Learning and Artificial Intelligence in Diagnostics)
  • Article
  • Open Access
3 Citations
3,398 Views
13 Pages

Advancing Phantom Fabrication: Exploring 3D-Printed Solutions for Abdominal Imaging Research

  • Muris Becircic,
  • Samir Delibegovic,
  • Adnan Sehic,
  • Fuad Julardzija and ,
  • Adnan Beganovic,
  • Kenana Ljuca,
  • Adi Pandzic and
  • Merim Jusufbegovic
  • + 3 authors+ 0 author

18 September 2024

Background: The development of novel medical imaging technologies and treatment procedures hinges on the availability of accurate and versatile phantoms. This paper presents a cost-effective approach for creating anthropomorphic abdominal phantoms. M...

(This article belongs to the Section Additive Manufacturing Technologies)
  • Article
  • Open Access
6 Citations
6,685 Views
9 Pages

Origami Lesion-Targeting Device for CT-Guided Interventions

  • Austin J. Taylor,
  • Sheng Xu,
  • Bradford J. Wood and
  • Zion Tsz Ho Tse

23 January 2019

The objective of this study is to preliminarily evaluate a lesion-targeting device for CT-guided interventions. The device is created by laser cutting the structure from a sheet of medical grade paperboard, 3D printing two radiocontrast agent grids o...

  • Article
  • Open Access
2 Citations
1,614 Views
19 Pages

Mimicking Tissues in 3D-Printed Radiology Phantoms: Brand, Product, and Color of Printing Filaments Matter!

  • Thomas Hofmann,
  • Martin Buschmann,
  • Adrian Belarra,
  • Maria Castillo-Garcia and ,
  • Margarita Chevalier,
  • Irene Hernandez-Giron and
  • Peter Homolka
  • + 2 authors+ 0 author

31 March 2026

Additive manufacturing enables the rapid fabrication of radiographic phantoms for X-ray and CT imaging, supporting applications such as patient simulation, dosimetry, imaging protocol optimization, and quality assurance. Polylactic acid (PLA) and acr...

(This article belongs to the Special Issue High-Performance Thermoplastic Polymer Composites: From Fabrication to Application)
  • Article
  • Open Access
3 Citations
4,756 Views
21 Pages

16 September 2025

Reducing radiation exposure in CT imaging is critical, particularly in routine and repeat examinations. Deep learning image reconstruction (DLIR) has emerged as a key approach for maintaining diagnostic quality at low-dose acquisition settings. This...

(This article belongs to the Section Medical Imaging)
  • Article
  • Open Access
3,545 Views
12 Pages

13 January 2023

This study evaluates ultra-low-dose computed tomography (ULDCT) protocols concerning the detectability of pulmonary nodules. The influence of tube current settings, kernels, strength levels of third-generation iterative reconstruction algorithms, and...

(This article belongs to the Special Issue Advances in Anatomy and Its History)
  • Article
  • Open Access
3 Citations
2,458 Views
18 Pages

Minimum Representative Human Body Model Size Determination for Link Budget Calculation in Implanted Medical Devices

  • Iñaki Ortego-Isasa,
  • Ainhoa Rezola,
  • Yue Gao,
  • Xiaodong Chen and
  • Daniel Valderas

29 June 2021

In this work, the optimum homogeneous phantom size for an equivalent whole-body electromagnetic (EM) modeling is calculated. This will enable the simple characterization of plane wave EM attenuation and far-field link budgets in Active Medical Implan...

  • Technical Note
  • Open Access
7 Citations
2,442 Views
10 Pages

1 July 2024

The calculation of effective doses is crucial in many medical and radiation fields in order to ensure safety and compliance with regulatory limits. Traditionally, Monte Carlo codes using detailed human body computational phantoms have been used for s...

(This article belongs to the Topic Artificial Intelligence in Public Health: Current Trends and Future Possibilities)
  • Article
  • Open Access
6 Citations
4,206 Views
18 Pages

Automated Task-Transfer Function Measurement for CT Image Quality Assessment Based on AAPM TG 233

  • Choirul Anam,
  • Riska Amilia,
  • Ariij Naufal,
  • Eko Hidayanto and ,
  • Heri Sutanto,
  • Lukmanda E. Lubis,
  • Toshioh Fujibuchi and
  • Geoff Dougherty
  • + 3 authors+ 0 author

18 August 2025

This study aims to develop and validate software for the automatic measurement of the task-transfer function (TTF) based on the American Association of Physicists in Medicine (AAPM) Task Group (TG) 233. The software consists of two main stages: autom...

  • Article
  • Open Access
2 Citations
1,361 Views
9 Pages

Simultaneous Estimation of Bias and Resolution in PET Images with a Long-Lived “Pocket” Phantom System

  • Paul E. Kinahan,
  • Darrin W. Byrd,
  • Brian Helba,
  • Kristen A. Wangerin and ,
  • Xiaoxiao Liu,
  • Joshua R. Levy,
  • Keith C. Allberg,
  • Karthik Krishnan and
  • Ricardo S. Avila
  • + 4 authors+ 0 author

A challenge in multicenter trials that use quantitative positron emission tomography (PET) imaging is the often unknown variability in PET image values, typically measured as standardized uptake values, introduced by intersite differences in global a...

of 9