You are currently on the new version of our website. Access the old version .

3,525 Results Found

  • Review
  • Open Access
56 Citations
10,888 Views
21 Pages

Skin Cancer Detection Using Infrared Thermography: Measurement Setup, Procedure and Equipment

  • Jan Verstockt,
  • Simon Verspeek,
  • Filip Thiessen,
  • Wiebren A. Tjalma,
  • Lieve Brochez and
  • Gunther Steenackers

26 April 2022

Infrared thermography technology has improved dramatically in recent years and is gaining renewed interest in the medical community for applications in skin tissue identification applications. However, there is still a need for an optimized measureme...

  • Review
  • Open Access
22 Citations
11,380 Views
30 Pages

A Review of Gas Measurement Set-Ups

  • Łukasz Fuśnik,
  • Bartłomiej Szafraniak,
  • Anna Paleczek,
  • Dominik Grochala and
  • Artur Rydosz

27 March 2022

Measurements of the properties of gas-sensitive materials are a subject of constant research, including continuous developments and improvements of measurement methods and, consequently, measurement set-ups. Preparation of the test set-up is a key as...

  • Article
  • Open Access
1 Citations
1,943 Views
17 Pages

Set-Up for Measuring Thermal Parameters of Power Semiconductor Devices

  • Krzysztof Górecki,
  • Przemysław Ptak,
  • Paweł Górecki and
  • Aleksander Data

In order to determine the junction temperature of semiconductor devices operating at different power supply and cooling conditions, their thermal parameters are needed. This article describes an original measurement set-up enabling the determination...

  • Article
  • Open Access
8 Citations
2,394 Views
14 Pages

Comparison of Properties for Selected Experimental Set-Ups Dedicated to Measuring Thermal Parameters of Power LEDs

  • Krzysztof Górecki,
  • Przemysław Ptak,
  • Marcin Janicki and
  • Małgorzata Napieralska

1 June 2021

This article compares properties of two measurement set-ups dedicated to determining thermal parameters of power LEDs. The standard T3Ster set-up and the custom set-up developed in Gdynia Maritime University are considered. Both set-ups are described...

  • Article
  • Open Access
1 Citations
1,672 Views
19 Pages

Measuring Precipitation via Microwave Bands with a High-Accuracy Setup

  • Alexandros Sakkas,
  • Vasilis Christofilakis,
  • Christos J. Lolis,
  • Spyridon K. Chronopoulos and
  • Kostas P. Peppas

17 December 2024

The urgent need for timely and accurate precipitation estimations in the face of ongoing climate change and the increasing frequency and/or intensity of extreme weather events underscores the necessity for innovative approaches. Recently, several stu...

  • Proceeding Paper
  • Open Access
4 Citations
2,538 Views
5 Pages

Contactless Sleep Monitoring Measurement Setup

  • Frederico Lima,
  • Almothana Albukhari,
  • Rui Zhu and
  • Ulrich Mescheder

20 November 2018

In this work, a contactless measurement setup based on a low-cost weighing scale sensor is presented. The positioning of the sensor is a key point in our work with ballistocardiographic (BCG) measurements. This was demonstrated using a strain-gauge s...

  • Article
  • Open Access
4 Citations
2,322 Views
12 Pages

Four-Point Measurement Setup for Correlative Microscopy of Nanowires

  • Bartosz C. Pruchnik,
  • Janusz D. Fidelus,
  • Ewelina Gacka,
  • Krzysztof Kwoka,
  • Julia Pruchnik,
  • Adrianna Piejko,
  • Łukasz Usydus,
  • Leszek Zaraska,
  • Grzegorz D. Sulka and
  • Tomasz Piasecki
  • + 1 author

30 August 2023

The measurement method, which utilizes nanomanipulation of the nanowires onto a specially prepared substrate, was presented. It introduced a four-point resistance measurement setup on a chip suited for scanning probe microscopy measurements, integrat...

  • Article
  • Open Access
11 Citations
5,534 Views
16 Pages

20 November 2018

Materials with a complex visual appearance, like goniochromatic or non-diffuse, are widely used for the packaging industry. Measuring optical properties of such materials requires a bidirectional approach, and therefore, it is difficult and time cons...

  • Article
  • Open Access
7 Citations
3,165 Views
19 Pages

10 August 2022

In this contribution, we present a measurement system for material characterization in the millimeter-wave range that requires extremely small amounts of sample material. With the help of a dielectric waveguide, it is possible to measure the complete...

  • Article
  • Open Access
6 Citations
3,230 Views
16 Pages

Setup for the Ionic Lifetime Measurement of the 229mTh3+ Nuclear Clock Isomer

  • Kevin Scharl,
  • Shiqian Ding,
  • Georg Holthoff,
  • Mahmood Irtiza Hussain,
  • Sandro Kraemer,
  • Lilli Löbell,
  • Daniel Moritz,
  • Tamila Rozibakieva,
  • Benedict Seiferle and
  • Florian Zacherl
  • + 1 author

24 July 2023

For the realization of an optical nuclear clock, the first isomeric excited state of thorium-229 (229mTh) is currently the only candidate due to its exceptionally low-lying excitation energy (8.338±0.024 eV). Such a nuclear clock holds promise...

  • Article
  • Open Access
5 Citations
4,030 Views
11 Pages

Characterization of the SIDDHARTA-2 Setup via the Kaonic Helium Measurement

  • Francesco Sgaramella,
  • Francesco Clozza,
  • Leonardo Abbene,
  • Francesco Artibani,
  • Massimiliano Bazzi,
  • Giacomo Borghi,
  • Mario Bragadireanu,
  • Antonino Buttacavoli,
  • Michael Cargnelli and
  • Marco Carminati
  • + 29 authors

The aim of the SIDDHARTA-2 experiment is to perform the first measurement ever of the width and shift induced by the strong interaction to the 2p→1s energy transition of kaonic deuterium. This ambitious goal implies a challenging task due to the...

  • Article
  • Open Access
3 Citations
4,893 Views
9 Pages

Intensity-Modulated PM-PCF Sagnac Loop in a DWDM Setup for Strain Measurement

  • Mateusz Mądry,
  • Lourdes Alwis and
  • Elżbieta Bereś-Pawlik

11 June 2019

A novel intensity-modulated Sagnac loop sensor based on polarization-maintaining photonic crystal fiber (PM-PCF) in a setup with a dense wavelength division multiplexer (DWDM) for strain measurement is presented. The sensor head is made of PM-PCF spl...

  • Article
  • Open Access
10 Citations
2,896 Views
10 Pages

Experimental Setup for Measurement of AC Loss in HTS under Rotating Magnetic Field

  • Wafa Ali Soomro,
  • Youguang Guo,
  • Haiyan Lu,
  • Jianxun Jin,
  • Boyang Shen and
  • Jianguo Zhu

23 October 2022

High-temperature superconducting materials have shown great potential for the design of large-scale industry applications. However, they are complicated under AC conditions, resulting in penalties such as power loss or AC loss. This loss has to be co...

  • Communication
  • Open Access
3 Citations
2,770 Views
12 Pages

3 February 2021

High temperatures complicate the direct measurements needed for continuous characterization of the properties of molten materials such as glass. However, the assumption that geometrical changes when the molten material is in free-fall can be correlat...

  • Article
  • Open Access
4 Citations
2,112 Views
13 Pages

17 January 2023

Specific parameters of cake filtration, such as the filter cake and filter medium resistances, can be determined using the pressurized housing cell standardized in the guideline VDI 2762 by measuring the filtrate mass on a laboratory scale. For repro...

  • Article
  • Open Access
1,353 Views
14 Pages

Design and Uncertainty Evaluation of a Calibration Setup for Turbine Blades Vibration Measurement

  • Lorenzo Capponi,
  • Giulio Tribbiani,
  • Vittoria Medici,
  • Sara Fabri,
  • Andrea Prato,
  • Paolo Castellini,
  • Alessandro Schiavi,
  • Nicola Paone and
  • Gianluca Rossi

17 December 2024

Turbomachinery engines face significant failure risks due to the combination of thermal loads and high-amplitude vibrations in turbine and compressor blades. Accurate stress distribution measurements are critical for enhancing the performance and saf...

  • Article
  • Open Access
24 Citations
7,205 Views
20 Pages

A Measurement Setup and Automated Calculation Method to Determine the Charge Injection Capacity of Implantable Microelectrodes

  • Ana Cisnal,
  • Juan-Carlos Fraile,
  • Javier Pérez-Turiel,
  • Victor Muñoz-Martinez,
  • Carsten Müller and
  • Frank R. Ihmig

27 November 2018

The design of safe stimulation protocols for functional electrostimulation requires knowledge of the “maximum reversible charge injection capacity” of the implantable microelectrodes. One of the main difficulties encountered in characteri...

  • Article
  • Open Access
3 Citations
1,695 Views
25 Pages

11 September 2024

Hyperthermia induces slight temperature increase of 4–8 °C inside the tumor, making it more responsive to radiation and drugs, thereby improving the outcome of the oncological treatment. To verify the level of heat in the tumor and to avoid...

  • Article
  • Open Access
3 Citations
3,154 Views
13 Pages

17 November 2021

In order to design electromagnetic applicators for diagnostic and therapeutic applications, an adequate dielectric tissue model is required. In addition, tissue temperature will heavily influence the dielectric properties and the dielectric model sho...

  • Article
  • Open Access
20 Citations
6,978 Views
21 Pages

Rapid Material Appearance Acquisition Using Consumer Hardware

  • Jiří Filip,
  • Radomír Vávra and
  • Mikuláš Krupička

22 October 2014

A photo-realistic representation of material appearance can be achieved by means of bidirectional texture function (BTF) capturing a material’s appearance for varying illumination, viewing directions, and spatial pixel coordinates. BTF captures many...

  • Article
  • Open Access
15 Citations
4,666 Views
13 Pages

31 August 2019

A simple sleep monitoring measurement method is presented in this paper, based on a simple, non-invasive motion sensor, the Passive InfraRed (PIR) motion sensor. The easy measurement set-up proposed is presented and its performances are compared with...

  • Review
  • Open Access
10 Citations
6,130 Views
21 Pages

Electrostatic discharge (ESD) is a physical phenomenon that may destroy electronic components due to its high discharge current that may reach a few amperes in just a few ns. However, another major aspect of ESD is the related high-frequency electrom...

  • Review
  • Open Access
7 Citations
5,922 Views
31 Pages

20 October 2022

In this paper, a unique overview of intelligent machines and mathematical methods designed and developed to measure and to control the water level in industrial or laboratory setups of coupled and cascaded configurations of tanks is made. A systemati...

  • Article
  • Open Access
14 Citations
4,098 Views
18 Pages

17 June 2019

Depending on their use, electrodes must have a certain size and design so as not to compromise their electrical characteristics. It is fundamental to be aware of all dependences on external factors that vary the electrochemical characteristics of the...

  • Article
  • Open Access
7 Citations
4,169 Views
14 Pages

Bidirectional Charging for BEVs with Reconfigurable Battery Systems via a Grid-Parallel Proportional-Resonant Controller

  • Johannes Buberger,
  • Michael Hohenegger,
  • Julian Estaller,
  • Andreas Wiedenmann,
  • Wolfgang Grupp,
  • Wolfgang Bliemetsrieder,
  • Manuel Kuder,
  • Anton Lesnicar and
  • Thomas Weyh

This paper investigates the potential of bidirectional charging using modular multilevel inverter-based reconfigurable battery systems via grid-parallel control. The system offers several advantages such as modularity, scalability, and fault-toleranc...

  • Article
  • Open Access
29 Citations
6,488 Views
13 Pages

Highly Efficient and Wide Range Humidity Response of Biocompatible Egg White Thin Film

  • Hafiz Mohammad Mutee Ur Rehman,
  • Muhammad Muqeet Rehman,
  • Muhammad Saqib,
  • Shenawar Ali Khan,
  • Maryam Khan,
  • Yunsook Yang,
  • Seongwan Kim,
  • Sheik Abdur Rahman and
  • Woo-Young Kim

13 July 2021

Biopolymers are a solution to solve the increasing problems caused by the advances and revolution in the electronic industry owing to the use of hazardous chemicals. In this work, we have used egg white (EW) as the low-cost functional layer of a bioc...

  • Article
  • Open Access
4 Citations
4,034 Views
10 Pages

Single Step 2-Port Device De-Embedding Algorithm for Fixture-DUT-Fixture Network Assembly

  • Simone Scafati,
  • Enza Pellegrino,
  • Francesco de Paulis,
  • Carlo Olivieri,
  • James Drewniak and
  • Antonio Orlandi

The de-embedding of measurement fixtures is relevant for an accurate experimental characterization of radio frequency and digital electronic devices. The standard technique consists in removing the effects of the measurement fixtures by the calculati...

  • Feature Paper
  • Review
  • Open Access
22 Citations
7,654 Views
30 Pages

Earth-to-Earth Microwave Rain Attenuation Measurements: A Survey On the Recent Literature

  • Vasilis Christofilakis,
  • Giorgos Tatsis,
  • Spyridon K. Chronopoulos,
  • Alexandros Sakkas,
  • Anastasios G. Skrivanos,
  • Kostas P. Peppas,
  • Hector E. Nistazakis,
  • Giorgos Baldoumas and
  • Panos Kostarakis

1 September 2020

Many works have been conducted relevant to rainfall measurements, while the first relevant ones were based on the power loss estimation function from wireless links located back to the early 1940s. It is notable, though, that this innovative idea con...

  • Article
  • Open Access
2,785 Views
22 Pages

26 August 2024

Permeability measurement of engineering textiles is a key step in preparing composite manufacturing processes. A radial flow experimental setup was used in this work to measure the unsaturated and saturated in-plane permeabilities of five different t...

  • Article
  • Open Access
3 Citations
6,611 Views
15 Pages

30 April 2020

In predicting the impact of vibrations propagated in a ground on newly designed construction objects, it is extremely important to reliably measure the time histories of velocity or acceleration at the site of the planned investment. As some studies...

  • Article
  • Open Access
5 Citations
3,699 Views
11 Pages

A New Setup for the Measurement of Total Organic Carbon in Ultrapure Water Systems

  • Sara H. Schäfer,
  • Katharina van Dyk,
  • Johannes Warmer,
  • Torsten C. Schmidt and
  • Peter Kaul

4 March 2022

With the increasing demand for ultrapure water in the pharmaceutical and semiconductor industry, the need for precise measuring instruments for those applications is also growing. One critical parameter of water quality is the amount of total organic...

  • Article
  • Open Access
15 Citations
10,942 Views
18 Pages

Prostate Cancer Detection with a Tactile Resonance Sensor—Measurement Considerations and Clinical Setup

  • Anders P. Åstrand,
  • Britt M. Andersson,
  • Ville Jalkanen,
  • Börje Ljungberg,
  • Anders Bergh and
  • Olof A. Lindahl

26 October 2017

Tumors in the human prostate are usually stiffer compared to surrounding non-malignant glandular tissue, and tactile resonance sensors measuring stiffness can be used to detect prostate cancer. To explore this further, we used a tactile resonance sen...

  • Article
  • Open Access
1 Citations
1,475 Views
24 Pages

Precise and Continuous Biomass Measurement for Plant Growth Using a Low-Cost Sensor Setup

  • Lukas Munser,
  • Kiran Kumar Sathyanarayanan,
  • Jonathan Raecke,
  • Mohamed Mokhtar Mansour,
  • Morgan Emily Uland and
  • Stefan Streif

2 August 2025

Continuous and accurate biomass measurement is a critical enabler for control, decision making, and optimization in modern plant production systems. It supports the development of plant growth models for advanced control strategies like model predict...

  • Article
  • Open Access
8 Citations
11,714 Views
17 Pages

Simple Setup for Measuring the Response to Differential Mode Noise of Common Mode Chokes

  • Pablo González-Vizuete,
  • Carlos Domínguez-Palacios,
  • Joaquín Bernal-Méndez and
  • María A. Martín-Prats

This work presents a technique to measure the attenuation of differential mode noise provided by common mode chokes. The proposed setup is a simpler alternative to the balanced setup commonly employed to that end, and its main advantage is that it av...

  • Article
  • Open Access
13 Citations
3,836 Views
17 Pages

Characterization of Particle Number Setups for Measuring Brake Particle Emissions and Comparison with Exhaust Setups

  • Theodoros Grigoratos,
  • Athanasios Mamakos,
  • Michael Arndt,
  • Dmytro Lugovyy,
  • Robert Anderson,
  • Christian Hafenmayer,
  • Mikko Moisio,
  • Joonas Vanhanen,
  • Richard Frazee and
  • Carlos Agudelo
  • + 1 author

3 January 2023

The stringency of vehicle exhaust emissions regulations resulted in a significant decrease in exhaust particulate matter (PM) emissions over the years. Non-exhaust particles (i.e., from brakes and tyres) account for almost half or more of road transp...

  • Article
  • Open Access
1 Citations
801 Views
16 Pages

Background/Objectives: A specially designed chamber setup for containment investigations of pharmaceutical dusts was recently developed. The aim of the present study was to optimize the measurement procedure with this chamber setup, focusing on the a...

  • Article
  • Open Access
2 Citations
2,384 Views
14 Pages

Comparison of Different Large Signal Measurement Setups for High Frequency Inductors

  • Jaime Lopez-Lopez,
  • Cristina Fernandez,
  • Andrés Barrado and
  • Pablo Zumel

The growing interest of miniaturized power converters has pushed the development of high frequency inductors integrated in Power Supply on Chip or Power Supply in Package. The proper characterization of inductor impedance is a challenge due to the de...

  • Article
  • Open Access
9 Citations
4,387 Views
23 Pages

A Wind Tunnel Setup for Fluid-Structure Interaction Measurements Using Optical Methods

  • Simon Nietiedt,
  • Tom T. B. Wester,
  • Apostolos Langidis,
  • Lars Kröger,
  • Robin Rofallski,
  • Martina Göring,
  • Martin Kühn,
  • Gerd Gülker and
  • Thomas Luhmann

2 July 2022

The design of rotor blades is based on information about aerodynamic phenomena. An important one is fluid-structure interaction (FSI) which describes the interaction between a flexible object (rotor blade) and the surrounding fluid (wind). However, t...

  • Article
  • Open Access
1 Citations
2,291 Views
13 Pages

Floc size distribution and settling velocities are crucial parameters for characterising cohesive sediments, as they influence how these sediments behave in various environmental settings. The accurate measurement of these properties is essential, wi...

  • Article
  • Open Access
3 Citations
3,820 Views
12 Pages

8 October 2021

This paper presents an experimental setup to measure the horizontal centering error of a pre-built pyroelectric infrared (PIR) sensor module, in which a dual-element PIR sensor is aligned at the focal point of a single-zone Fresnel Lens. In the setup...

  • Article
  • Open Access
6 Citations
2,205 Views
12 Pages

Development of a Simple Setup to Measure Shielding Effectiveness at Microwave Frequencies

  • Emanuele Cardillo,
  • Fabrizio Lorenzo Carcione,
  • Luigi Ferro,
  • Elpida Piperopoulos,
  • Emanuela Mastronardo,
  • Graziella Scandurra and
  • Carmine Ciofi

8 June 2024

Testing the shielding effectiveness of materials is a key step for many applications, from the industrial to the biomedical field. This task is very relevant for high-sensitivity sensors, whose performance can be greatly affected by electromagnetic f...

  • Article
  • Open Access
6 Citations
3,691 Views
19 Pages

Flicker Noise in Resistive Gas Sensors—Measurement Setups and Applications for Enhanced Gas Sensing

  • Janusz Smulko,
  • Graziella Scandurra,
  • Katarzyna Drozdowska,
  • Andrzej Kwiatkowski,
  • Carmine Ciofi and
  • He Wen

9 January 2024

We discuss the implementation challenges of gas sensing systems based on low-frequency noise measurements on chemoresistive sensors. Resistance fluctuations in various gas sensing materials, in a frequency range typically up to a few kHz, can enhance...

  • Review
  • Open Access
9 Citations
3,043 Views
13 Pages

Characterization of Laboratory Particulate Matter (PM) Mass Setups for Brake Emission Measurements

  • Theodoros Grigoratos,
  • Athanasios Mamakos,
  • RaviTeja Vedula,
  • Michael Arndt,
  • Dmytro Lugovyy,
  • Christian Hafenmayer,
  • Mikko Moisio,
  • Carlos Agudelo and
  • Barouch Giechaskiel

7 March 2023

Vehicles’ exhaust particulate matter (PM) emissions have significantly decreased over the years. On the other hand, non-exhaust emissions, i.e., particle emissions from brakes and tires, have increased due to the increase in the vehicle fleet,...

  • Article
  • Open Access
2 Citations
4,207 Views
17 Pages

Development and Validation of a Novel Setup for LEDs Lifetime Estimation on Molded Interconnect Devices

  • Mahdi Soltani,
  • Moritz Freyburger,
  • Romit Kulkarni,
  • Rainer Mohr,
  • Tobias Groezinger and
  • André Zimmermann

Higher energy efficiency, more compact design, and longer lifetime of light-emitting diodes (LEDs) have resulted in increasing their market share in the lighting industry, especially in the industries of consumer electronics, automotive, and general...

  • Article
  • Open Access
2,949 Views
20 Pages

29 September 2020

The ability to separate and filter out microscopic objects lies at the core of many biomedical applications. However, a persistent problem is clogging, as biomaterials stick to the internal chip surface and limit device efficiency and liability. Here...

  • Review
  • Open Access
9 Citations
2,112 Views
17 Pages

26 May 2023

In this review article, ideas for the development of measuring methods and setups to test inductive instrument transformer accuracy for the transformation of distorted current or voltage are analyzed. This article proposes limiting values for ratio e...

  • Article
  • Open Access
6 Citations
3,555 Views
12 Pages

The TeraFERMI Electro-Optic Sampling Set-Up for Fluence-Dependent Spectroscopic Measurements

  • Nidhi Adhlakha,
  • Paola Di Pietro,
  • Federica Piccirilli,
  • Paolo Cinquegrana,
  • Simone Di Mitri,
  • Paolo Sigalotti,
  • Simone Spampinati,
  • Marco Veronese,
  • Stefano Lupi and
  • Andrea Perucchi

TeraFERMI is the THz beamline at the FERMI free-electron-laser facility in Trieste (Italy). It uses superradiant Coherent Transition Radiation emission to produce THz pulses of 10 to 100 μ J intensity over a spectral range which can extend up...

  • Article
  • Open Access
31 Citations
4,412 Views
13 Pages

Are Inductive Current Transformers Performance Really Affected by Actual Distorted Network Conditions? An Experimental Case Study

  • Alessandro Mingotti,
  • Lorenzo Peretto,
  • Lorenzo Bartolomei,
  • Diego Cavaliere and
  • Roberto Tinarelli

10 February 2020

The aim of this work is to assess whether actual distorted conditions of the network are really affecting the accuracy of inductive current transformers. The study started from the need to evaluate the accuracy performance of inductive current transf...

  • Article
  • Open Access
3 Citations
3,866 Views
18 Pages

Laboratory Calibration of Energy Measurement Systems (EMS) under AC Distorted Waveforms

  • Daniela Istrate,
  • Abderrahim Khamlichi,
  • Soureche Soccalingame,
  • Jorge Rovira,
  • Dominique Fortune,
  • Martin Sira,
  • Pascual Simon and
  • Fernando Garnacho

5 November 2020

Current standard EN 50463-2 indicates the tests and the requirements to be satisfied for an energy measurement system of a traction unit for railway applications. Some of these tests are to be done with several harmonics superposed on the rated volta...

  • Article
  • Open Access
1,432 Views
20 Pages

Diffusion Potentials in Cement Mortars with pH Differences Due to Carbonation

  • Elke Ziehensack,
  • Kai Osterminski and
  • Christoph Gehlen

Corrosion investigations of steel-reinforced concrete structures are often based on half-cell potential measurements, in which the diffusion potentials can be a significant source of measurement errors. Therefore, the diffusion potentials must be tak...

of 71