Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (33)

Search Parameters:
Keywords = CFRP jacket

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
31 pages, 7206 KB  
Article
Damage and Capacity Diagnostics of CFRP-Jacketed Non-Ductile RC Frames
by Resat Oyguc, Aytac Yasargun, Ali Yesilyurt, Evrim Oyguc and Ferit Cakir
Buildings 2026, 16(12), 2369; https://doi.org/10.3390/buildings16122369 - 13 Jun 2026
Viewed by 266
Abstract
Non-ductile reinforced concrete frames with unconfined joints dominate the collapse hazard of the existing building stock. Their CFRP-retrofit margin at collapse demand is poorly quantified. Two one-third-scale portal sub-frames were tested under Froude similitude. Specimen 1 was bare. Specimen 2 carried a three-ply [...] Read more.
Non-ductile reinforced concrete frames with unconfined joints dominate the collapse hazard of the existing building stock. Their CFRP-retrofit margin at collapse demand is poorly quantified. Two one-third-scale portal sub-frames were tested under Froude similitude. Specimen 1 was bare. Specimen 2 carried a three-ply hoop CFRP jacket on columns, beams, and joints. Both received the Antakya 3141 record from the 2023 Kahramanmaraş Mw 7.7 mainshock at design intensity 0.35 g and collapse intensity 1.0 g. Cyclic response was decomposed into flexural, shear, and slip energy. At design intensity, the retrofit cut peak roof drift by 54%, suppressed residual offset, and lowered the calibrated Park–Ang index from 0.89 to 0.32. Slip share dropped from 47% to 5%. At collapse intensity, the retrofitted frame transitioned to joint-panel debonding-controlled failure at 8% drift with 245 mm residual, and shear share rose to 64%. The dominant-half-cycle ratio R1 ≈ 0.72 emerged as a candidate brittle-damage signature for collapse-level response. A Lam–Teng confinement check confirms that the failure migrates from the column ends to debonding fracture in the wrapped panel rather than being eliminated by the retrofit. Supplementary joint-corner anchorage is recommended for non-ductile joints at collapse demand. Full article
Show Figures

Figure 1

36 pages, 7218 KB  
Article
Effectiveness of Passive CFRP and Active Fe-SMA Confinement in Enhancing Drift Capacity and Seismic Performance of RC Columns Under Extreme Drift Levels
by Adel Al Ekkawi and Raafat El-Hacha
Buildings 2026, 16(1), 243; https://doi.org/10.3390/buildings16010243 - 5 Jan 2026
Viewed by 1076
Abstract
This study presents an experimental investigation into the seismic performance of seismically deficient reinforced concrete (RC) bridge columns retrofitted with passive and active confinement systems. Four single-cantilever RC columns, representing 1/3-scale bridge piers, were constructed with poor transverse reinforcement detailing to simulate seismic [...] Read more.
This study presents an experimental investigation into the seismic performance of seismically deficient reinforced concrete (RC) bridge columns retrofitted with passive and active confinement systems. Four single-cantilever RC columns, representing 1/3-scale bridge piers, were constructed with poor transverse reinforcement detailing to simulate seismic deficiency. One column was left un-strengthened for baseline comparison, while the remaining three were retrofitted using: (1) a CFRP jacket, (2) welded Fe-SMA plates, and (3) bolted Fe-SMA plates. All columns were subjected to quasi-static lateral cyclic push-only loading reaching extreme drift levels exceeding 16% and high loading rates up to 6 mm/s. The study specifically explores the confinement effectiveness of CFRP and thermally activated Fe-SMA plates, comparing their contributions to lateral strength, ductility, energy dissipation, failure mode, and damage suppression. The results show that while the as-built column failed at 3.65% drift due to brittle flexural-shear failure, all retrofitted columns demonstrated significantly enhanced ductility, drift capacity, and post-peak behaviour. The CFRP and Fe-SMA jackets effectively delayed damage initiation, minimized core degradation, and improved energy dissipation. The bolted Fe-SMA system exhibited the highest and full restoration of lateral strength, while the welded system achieved the greatest increase in cumulative energy dissipation of around 40%. This research highlights the practical advantages and seismic effectiveness of Fe-SMA and CFRP confinement systems under extreme drift levels. However, future work should explore full-scale column applications, refine anchorage techniques for improved composite interaction, and investigate long-term durability under cyclic environmental conditions. Full article
Show Figures

Figure 1

24 pages, 3275 KB  
Article
Multiple Regression and Neural Network-Based Models for the Prediction of the Ultimate Strength of CFRP-Confined Columns
by Baylasan Mohamad, Muna Hamadeh, Firas Al Mahmoud and George Wardeh
Infrastructures 2025, 10(12), 326; https://doi.org/10.3390/infrastructures10120326 - 1 Dec 2025
Viewed by 641
Abstract
Carbon Fiber-Reinforced Polymers (CFRPs) are gaining popularity as a reliable strengthening technique for reinforced concrete (RC) columns. Several efficient models were developed to predict the stress–strain (σ-ε) curve of CFRP-confined concrete based on experiment findings. The ultimate strength is a crucial parameter for [...] Read more.
Carbon Fiber-Reinforced Polymers (CFRPs) are gaining popularity as a reliable strengthening technique for reinforced concrete (RC) columns. Several efficient models were developed to predict the stress–strain (σ-ε) curve of CFRP-confined concrete based on experiment findings. The ultimate strength is a crucial parameter for accurate (σ-ε) behavior prediction, since it constitutes an initial step in estimating the corresponding axial strain, as it provides a direct indication of the desired increase in strength. Literature analytical models often produce inconsistent results due to errors in estimating the confinement pressure or effectively confined area or the lack of a strong and stable correlation between ultimate strength and confinement parameters. This study looked at a large collection of experimental results from existing research. It used a statistical method (Pearson’s coefficient) to see how well ultimate strength correlated with various confinement factors. For normal-strength concrete columns with circular sections, there was a strong linear correlation between ultimate strength and the thickness of the CFRP jacket. This correlation weakened for high-strength concrete (HSC) and for rectangular columns. A sensitivity analysis was performed to identify the most influential confinement parameters, showing that the number of CFRP layers (n × t) is the most dominant factor, particularly with normal-strength concrete (NSC) in circular columns, accounting for the vast majority of the variance in ultimate strength. Using multiple linear regression equations to predict ultimate strength was also explored; this method demonstrated the best performance with HSC in circular sections, but the results were less promising with NSC. Artificial Neural Networks (ANNs) were developed and trained on the built database, and four statistical metrics were computed for evaluation (R2, RMSE, MAE, MRAE), proving highly accurate and superior to linear regression equations, with mean relative absolute errors MRAEs between 2.4–7.2% for ultimate strength prediction, opening new avenues for optimizing CFRP-strengthened element designs. Full article
Show Figures

Figure 1

27 pages, 6456 KB  
Article
Strengthening Width on Local Damage to Circular Piers Caused by Rolling Boulder Impacts
by Zijian Wang, Junjie Li, Ling Ling, Haoran Luo, Linming Wu, Xingyu Zhou and Yi Wang
Buildings 2025, 15(23), 4347; https://doi.org/10.3390/buildings15234347 - 30 Nov 2025
Cited by 1 | Viewed by 646
Abstract
In response to the issue of local damage to mountainous bridges easily caused by rockfall impacts, carbon fiber cloth and steel plate strengthening methods were adopted to deeply study the impact of the width of carbon fiber cloth and steel plates on the [...] Read more.
In response to the issue of local damage to mountainous bridges easily caused by rockfall impacts, carbon fiber cloth and steel plate strengthening methods were adopted to deeply study the impact of the width of carbon fiber cloth and steel plates on the strengthening effect. This study investigates the strengthening effectiveness of Carbon Fiber-Reinforced Polymer (CFRP) wraps and steel jackets on circular bridge piers, utilizing the ABAQUS finite element method. The analysis focuses on the effects of varying load conditions and confinement widths ranging from 100 to 200 cm, with a specific case study of a bridge pier in Nanchuan District, Chongqing. The research results show that the width of carbon fiber cloth and steel plates has a significant impact on the bridge pier’s impact resistance and damage resistance. There exists an optimal strengthening width that maximizes the strengthening effect. The stress distribution and displacement changes under different load conditions are affected by the width of the steel plate; the wider the steel plate, the better the strengthening effect, but the effect is not strictly linear. A comprehensive analysis method integrating multi-directional stress and displacement data was developed, incorporating weighting factors based on structural safety relevance. For both strengthening methods, a set of fitted formulas for widths between 100 cm and 200 cm was derived. This study provides systematic insights and practical guidance for the design of impact-resistant strengthening systems for bridge piers. Full article
(This article belongs to the Section Building Structures)
Show Figures

Figure 1

8 pages, 1010 KB  
Proceeding Paper
Evaluation of Innovative and Sustainable Fire Protection Systems for Reinforced Concrete Structures
by Louai Wafa, Ayman Mosallam and Ashraf Abed-Elkhalek Mostafa
Eng. Proc. 2025, 112(1), 62; https://doi.org/10.3390/engproc2025112062 - 4 Nov 2025
Viewed by 714
Abstract
This study presents a comprehensive overview of recent advancements in fire protection technologies for reinforced concrete (RC) structures, with a focus on sustainable and high-performance solutions. As climate change and urban densification continue to shape modern construction, the need for fire-resilient and environmentally [...] Read more.
This study presents a comprehensive overview of recent advancements in fire protection technologies for reinforced concrete (RC) structures, with a focus on sustainable and high-performance solutions. As climate change and urban densification continue to shape modern construction, the need for fire-resilient and environmentally responsible building systems has never been more urgent. This study examines traditional fire protection practices and contrasts them with emerging innovations. Emphasis is placed on their thermal performance, structural integrity post-exposure, and long-term durability. Case studies and laboratory findings highlight the effectiveness of these systems under standard and severe fire scenarios. This paper will present the results of a research study on the assessment of different fire protection systems for RC columns retrofitted with fiber-reinforced polymer (FRP) jacketing. To quantify how insulation can preserve confinement, three commercial fire protection schemes were tested on small-scale CFRP- and GFRP-confined concrete cylinders: (i) a thin high-temperature cloth + blanket (DYMAT™-RS/Dymatherm), (ii) an intumescent epoxy-based coating (DCF-D + FireFree 88), and (iii) cementitious mortar (Sikacrete™ 213F, 15 mm and 30 mm). Specimens were exposed to either 60 min of soaking at 200 °C and 400 °C or to a 30 min and 240 min ASTM E119 standard fire; thermocouples recorded interface temperatures and post-cooling uniaxial compression quantified residual capacity. All systems reduced FRP–interface temperatures by up to 150 °C and preserved 65–90% of the original confinement capacity under moderate fire conditions (400 °C and 30 min ASTM E119) compared to 40–55% for unprotected controls under the same conditions. The results provide practical guidance on selecting insulation types and thicknesses for fire-resilient FRP retrofits. Full article
Show Figures

Figure 1

21 pages, 1538 KB  
Article
A Hybrid Fuzzy DEMATEL–DANP–TOPSIS Framework for Life Cycle-Based Sustainable Retrofit Decision-Making in Seismic RC Structures
by Paola Villalba, Antonio J. Sánchez-Garrido, Lorena Yepes-Bellver and Víctor Yepes
Mathematics 2025, 13(16), 2649; https://doi.org/10.3390/math13162649 - 18 Aug 2025
Cited by 5 | Viewed by 2313
Abstract
Seismic retrofitting of reinforced concrete (RC) structures is essential for improving resilience and extending service life, particularly in regions with outdated building codes. However, selecting the optimal retrofitting strategy requires balancing multiple interdependent sustainability criteria—economic, environmental, and social—under expert-based uncertainty. This study presents [...] Read more.
Seismic retrofitting of reinforced concrete (RC) structures is essential for improving resilience and extending service life, particularly in regions with outdated building codes. However, selecting the optimal retrofitting strategy requires balancing multiple interdependent sustainability criteria—economic, environmental, and social—under expert-based uncertainty. This study presents a fuzzy hybrid multi-criteria decision-making (MCDM) approach that combines DEMATEL, DANP, and TOPSIS to represent causal interdependencies, derive interlinked priority weights, and rank retrofit alternatives. The assessment applies three complementary life cycle-based tools—cost-based, environmental, and social sustainability analyses following LCCA, LCA, and S-LCA frameworks, respectively—to evaluate three commonly used retrofitting strategies: RC jacketing, steel jacketing, and carbon fiber-reinforced polymer (CFRP) wrapping. The fuzzy-DANP methodology enables accurate modeling of feedback among sustainability dimensions and improves expert consensus through causal mapping. The findings identify CFRP as the top-ranked alternative, primarily attributed to its enhanced performance in both environmental and social aspects. The model’s robustness is confirmed via sensitivity analysis and cross-method validation. This mathematically grounded framework offers a reproducible and interpretable tool for decision-makers in civil infrastructure, enabling sustainability-oriented retrofitting under uncertainty. Full article
(This article belongs to the Special Issue Multi-criteria Decision Making and Data Mining, 2nd Edition)
Show Figures

Figure 1

22 pages, 7385 KB  
Article
Axial Performances of CFRP-PVC Confined RAC Columns: Experimental and Numerical Study
by Zidong Hu, Ruoyu Cao, Qiaoyun Wu, Cheng Zhao, Jie Li and Xuyong Chen
Buildings 2025, 15(12), 2089; https://doi.org/10.3390/buildings15122089 - 17 Jun 2025
Viewed by 1055
Abstract
The use of recycled aggregate concrete (RAC) in construction mitigates environmental pollution by repurposing demolition waste, but its lower compressive strength compared to natural aggregate concrete (NAC) limits broader application. Although carbon fiber reinforced polymer (CFRP) composites and polyvinyl chloride (PVC) tubes have [...] Read more.
The use of recycled aggregate concrete (RAC) in construction mitigates environmental pollution by repurposing demolition waste, but its lower compressive strength compared to natural aggregate concrete (NAC) limits broader application. Although carbon fiber reinforced polymer (CFRP) composites and polyvinyl chloride (PVC) tubes have individually been shown to improve concrete strength and ductility, existing studies focus on fully wrapped CFRP jackets on NAC columns and do not systematically explore CFRP–PVC hybrid confinement using strips on RAC. To address this research gap, this study investigates the axial compressive behavior of CFRP–PVC–RAC columns by varying CFRP strip width (from 25 to 75 mm), strip spacing (from 31 to 77.5 mm), and the number of CFRP layers (one to nine) over a central PVC tube. Axial compression tests reveal that specimens with a central CFRP strip width equal to or greater than 75 mm achieve peak loads up to 1331 kN and that, after rupture of the central strip, the remaining strips continue to carry load, producing a more gradual stress–strain decline and enhanced ductility compared to fully wrapped controls (peak load 1219 kN). These results show that CFRP–PVC composites enhance the axial compressive strength and ductility of RAC columns. The confinement mechanism increases the ultimate axial strain and redistributes transverse stresses, delaying brittle failure and improving deformation capacity. When two or more CFRP layers are applied, strip width and spacing affect axial stress by no more than three percent. Increasing layers from one to four raises axial strength by approximately 23 percent, whereas adding layers beyond four yields diminishing returns, with less than a six percent increase. Finally, a multilayer lateral confined pressure formula is derived and validated against thirty-two specimens, exhibiting errors no greater than three percent and accurately predicting effective confinement. These findings offer practical guidance for optimizing strip dimensions and layering in CFRP–PVC reinforcement of RAC columns, achieving material savings without compromising performance. Full article
Show Figures

Figure 1

8 pages, 4501 KB  
Proceeding Paper
Parametric Investigation of Fatigue-Cracked Tubular T-Joint Repair Using Composite Reinforcement
by Muhammad Hazim, Saravanan Karuppanan and Mohsin Iqbal
Eng. Proc. 2025, 87(1), 38; https://doi.org/10.3390/engproc2025087038 - 8 Apr 2025
Cited by 1 | Viewed by 918
Abstract
Circular hollow sections (CHSs) are widely used in offshore jacket structures due to their excellent compressive strength, torsional resistance, and direction-independent stiffness. However, CHS joints are prone to fatigue-induced cracking caused by complex geometries, environmental loading, and aging. Fatigue crack propagation, governed by [...] Read more.
Circular hollow sections (CHSs) are widely used in offshore jacket structures due to their excellent compressive strength, torsional resistance, and direction-independent stiffness. However, CHS joints are prone to fatigue-induced cracking caused by complex geometries, environmental loading, and aging. Fatigue crack propagation, governed by the stress intensity factor (SIF), threatens structural integrity if the SIF exceeds fracture toughness. Composite reinforcement has emerged as a promising solution for mitigating crack propagation and enhancing joint performance. This study presents a numerical parametric investigation of fatigue-cracked tubular T-joints, focusing on the effects of crack size, crack location, and composite reinforcement on the SIF under various loading conditions. The highest SIF was consistently observed at the saddle point in T-joints under axial and out-of-plane bending (OPB) loads. However, in T-joints subjected to in-plane bending (IPB) loads, the highest SIF was found between the crown and saddle points. The SIF increased with the size and diameter of the cracks. The application of CFRP wrapping was found to reduce the SIF by more than 50% across all loading conditions, with the most significant reductions observed when the reinforcement was oriented along the chord axis. Full article
(This article belongs to the Proceedings of The 5th International Electronic Conference on Applied Sciences)
Show Figures

Figure 1

38 pages, 9959 KB  
Article
Application of Carbon-Fiber-Reinforced Polymer Rods and Ultra-High-Performance Fiber-Reinforced Concrete Jackets with Mechanical Anchorage Systems to Reinforced Concrete Slabs
by Firas Hassan Saeed and Farzad Hejazi
Fibers 2025, 13(3), 33; https://doi.org/10.3390/fib13030033 - 13 Mar 2025
Cited by 1 | Viewed by 3710
Abstract
The aim of this experimental study was to develop and evaluate the effectiveness of a new strengthening system for reinforced concrete slabs employing external jackets consisting of ultra-high-performance fiber-reinforced-concrete (UHPFRC) and mechanical anchor systems. The issue of debonding between old and fresh concrete [...] Read more.
The aim of this experimental study was to develop and evaluate the effectiveness of a new strengthening system for reinforced concrete slabs employing external jackets consisting of ultra-high-performance fiber-reinforced-concrete (UHPFRC) and mechanical anchor systems. The issue of debonding between old and fresh concrete layers, as well as the efficiency of utilizing CFRP rods, is the primary challenge of applying the UHPFRC jackets with embedded CFRP rods. In this study, we propose a novel retrofitting technique for implementing a mechanical anchor system to improve the binding of fresh UHPFRC jackets with old RC slabs. An experimental test was conducted by subjecting three slabs to cyclic loads by utilizing a dynamic actuator: a reference slab, a retrofitted slab with an external UHPFRC layer, and a retrofitted slab with an external UHPFRC layer incorporating CFRP bars. Furthermore, finite element models (FEMs) were utilized to investigate the responses of the retrofitted slabs and compare the novel method with traditional strengthening techniques, including near-surface-mounted (NSM) CFRP rods, externally bonded CFRP strips, and epoxy-bonded UHPFRC jackets, as well as two models that were the same as the experimental strengthened slab specimens except for the fact that they did not have a mechanical anchor system. Additionally, analytical mechanistic models were employed to determine the flexural moment capacity of the RC slabs. The experimental findings demonstrated that the proposed strengthening strategy considerably prevented premature debonding and enhanced the maximum load of retrofitted RC slabs by over 82%. Also, the FEM and analytical results are significantly consistent with the experimental outcomes. In conclusion, the newly suggested strengthening technique is a reliable system for enhancing the efficacy of slabs, effectively preventing early debonding between existing and new components. Full article
Show Figures

Figure 1

19 pages, 13847 KB  
Article
Effect of GFRP and CFPR Hybrid Confinement on the Compressive Performance of Concrete
by Marina L. Moretti
Fibers 2025, 13(2), 12; https://doi.org/10.3390/fib13020012 - 24 Jan 2025
Cited by 1 | Viewed by 2162
Abstract
Application of hybrid jackets consisting of comparatively stiff FRP materials for the seismic retrofit of substandard RC columns, aiming at reducing the risk of buckling and of brittle failure, which are typical to older columns, is a promising challenge. Given the sparsity of [...] Read more.
Application of hybrid jackets consisting of comparatively stiff FRP materials for the seismic retrofit of substandard RC columns, aiming at reducing the risk of buckling and of brittle failure, which are typical to older columns, is a promising challenge. Given the sparsity of similar experimental data, the objective of this paper is to study the hybrid effect in concrete confined with conventional carbon- and glass- reinforced polymer fabrics (CFRP and GFRP, respectively). Twenty-six concrete cylinders, wrapped by one to three layers of CFRP and GFRP with different fiber configurations, were tested in compression. A clear hybrid effect was observed, consisting of a less brittle failure and an improved confinement as compared to the behavior of simple jackets. Furthermore, hybrid specimens, in which a CFRP layer is substituted by a GFRP layer, appear to display similar efficiency in confinement compared to specimens with a stiffer jacket consisting of more CFRP sheets, which are expected to experience 30 to 40% higher lateral pressure owing to the stiffer jacket. A design model to estimate peak concrete compressive strength and axial strain is proposed. The results are promising towards the potential application of similar hybrid jackets for the seismic rehabilitation of older RC columns. Full article
(This article belongs to the Special Issue Fracture Behavior of Fiber-Reinforced Building Materials)
Show Figures

Figure 1

26 pages, 10277 KB  
Article
Rehabilitation and Strengthening of Damaged Reinforced Concrete Beams Using Carbon Fiber-Reinforced Polymer Laminates and High-Strength Concrete Integrating Recycled Tire Steel Fiber
by Hasan A. Alasmari, Ibrahim A. Sharaky, Ahmed S. Elamary and Ayman El-Zohairy
Fibers 2025, 13(1), 10; https://doi.org/10.3390/fib13010010 - 15 Jan 2025
Cited by 6 | Viewed by 4176
Abstract
Currently, millions of tires are consumed annually, which necessitates the efficient disposal of these quantities of spent tires and the development of means to convert them into useful materials. This research deals with the effect of adding the steel fibers extracted from used [...] Read more.
Currently, millions of tires are consumed annually, which necessitates the efficient disposal of these quantities of spent tires and the development of means to convert them into useful materials. This research deals with the effect of adding the steel fibers extracted from used car tires (RSFs) to incorporate them as concrete components to obtain high-strength concrete (HSC). The HSC was used in this paper to strengthen the pre-damaged beams by jacking. In the first phase, twelve beams were subjected to an overload equal to 80% of their total expected bearing capacity to obtain damaged RC beams, while one beam was loaded to failure (reference beam, RB0). In the second phase, the damaged beams were strengthened with HSC jacketing integrating RSFs with three contents (0, 0.25, and 0.5%) or by HSC jacking and bonded CFRP laminates to the bottom surface of the jacket. Moreover, the Abaqus finite element (FE) program was implemented to simulate the upgraded damaged beams. The result ensured enhanced HSC compressive and tensile strengths by 11.6–14.4% and 11.6–20.9% as the RSF % increased from 0 to 0.25 and 0.5%, respectively. Using the HSC jacket with 0, 0.25, and 0.5% RSF to strengthen the RC-damaged beams increased the load capacity by 8.8, 14.5, and 20.1%, respectively compared to RB0. Furthermore, strengthening the damaged RC beams with both HSC jacket and CFRP laminates enhanced their load capacity by 41.9, 45.5, and 50.3% as the HSC integrated 0, 0.25, and 0.5% RSF, respectively, compared to RB0. Finally, the FE model could reveal several aspects related to the behavior of the damaged beams strengthened with jackets and CFRP laminates and the interaction between the different beam components. Full article
Show Figures

Figure 1

19 pages, 2022 KB  
Article
Environmental and Economic LCA Comparison of Flexural Strengthening Solutions for a Reinforced Concrete Beam
by Pedro Frazão Pedroso, João R. Correia, José D. Silvestre, João P. Firmo and Mário Garrido
Materials 2024, 17(23), 5879; https://doi.org/10.3390/ma17235879 - 30 Nov 2024
Cited by 4 | Viewed by 1650
Abstract
The construction sector is one of the largest creators and distributors of wealth, contributing to economic growth worldwide. However, this economic growth comes together with very high environmental impacts. Thus, rehabilitation solutions that can adapt the current building stock to today’s structural requirements [...] Read more.
The construction sector is one of the largest creators and distributors of wealth, contributing to economic growth worldwide. However, this economic growth comes together with very high environmental impacts. Thus, rehabilitation solutions that can adapt the current building stock to today’s structural requirements are needed, increasing structural safety, while avoiding the production of demolition waste and the extraction of virgin raw materials, hence lowering the construction sector’s environmental impacts. Such rehabilitation solutions need to be environmentally and economically sound so that stakeholders can make informed decisions based on their needs and priorities. This paper presents a case study of an existing reinforced concrete beam, whose flexural resistance is increased using four alternative strengthening solutions: concrete jacketing, without and with increasing the cross-section size, and plate bonding, using either carbon fibre-reinforced polymer (CFRP) strips or steel plates. These solutions are studied via an environmental and economic cradle-to-gate life cycle assessment (LCA), resulting in a comprehensive comparison of their environmental and economic impacts, followed by a multicriteria and sensitivity analysis and eco-cost approach to determine the optimal solution. According to the criteria considered in the study, when environmental impacts are more valued, the concrete jacketing solution presents the best results and, when cost is dominant in the decision, the bonding of CFRP strips becomes the optimal solution. Full article
Show Figures

Figure 1

34 pages, 11583 KB  
Article
Strengthening Reinforced Concrete Beams through Integration of CFRP Bars, Mechanical Anchorage System, and Concrete Jacketing
by Mahmood Y. Alkhateeb and Farzad Hejazi
Materials 2024, 17(12), 2794; https://doi.org/10.3390/ma17122794 - 7 Jun 2024
Cited by 8 | Viewed by 5206
Abstract
The demand for strengthening reinforced concrete (RC) structures has increased considerably. Implementing carbon-fiber-reinforced polymer (CFRP) bars and concrete jacketing are the most effective techniques for RC beam retrofitting. Using the mechanical anchorage system (MAS) to attach CFRP bars to old concrete is highly [...] Read more.
The demand for strengthening reinforced concrete (RC) structures has increased considerably. Implementing carbon-fiber-reinforced polymer (CFRP) bars and concrete jacketing are the most effective techniques for RC beam retrofitting. Using the mechanical anchorage system (MAS) to attach CFRP bars to old concrete is highly recommended to avoid any debonding when it is applied to cyclic loads. However, the design of strengthening details is the most challenging issue because it involves many effective parameters. In this study, a design process for strengthening beams using CFRP bars with new MASs and concrete jacketing is proposed, and various design schemes are studied. The number of applied MASs and the thickness and grade of the concrete jacket were investigated through experimental testing and finite element (FE) simulations to define strengthening design details, such as the number and size of employed CFRP bars. Accordingly, an analytical technique was formulated to predict the performance of the strengthened beam in terms of the nominal ultimate load. The results demonstrated the high performance of the proposed system in preventing premature debonding. The proposed system enhances the beam capacity from 44 kN to 83 kN, representing an increase of more than 90%. In contrast, the conventional near-surface mounted (NSM) system exhibits a lower percentage increase at less than 37%. Both FE simulations and analytical approaches can be effectively employed to predict the behavior and capacity of the strengthened beam while considering various design parameters. Full article
Show Figures

Figure 1

22 pages, 7771 KB  
Article
Seismic Retrofit of Concrete Buildings Damaged by Corrosion: A Case Study in Southern Italy
by Michele Fabio Granata
Buildings 2024, 14(4), 1064; https://doi.org/10.3390/buildings14041064 - 11 Apr 2024
Cited by 14 | Viewed by 5245
Abstract
A case study of a building in southern Italy, subjected to high degradation by corrosion and waiting to be assessed for retrofit interventions, is presented. The owner required modifications to the building configuration, including a new layout of the floors and retrofitting for [...] Read more.
A case study of a building in southern Italy, subjected to high degradation by corrosion and waiting to be assessed for retrofit interventions, is presented. The owner required modifications to the building configuration, including a new layout of the floors and retrofitting for a high level of seismic load. A double strategy of an assessment and retrofit was carried out: dynamic linear and static non-linear analyses were performed, and the results were compared. Afterwards, a global strategy of mass and stiffness redistribution was implemented together with different retrofit interventions on the foundations, columns, and beams of the framed structure, such as reinforced concrete and steel jacketing, the application of FRP plates and fabrics, new steel elements, and steel–concrete composite floors. The results of the intervention are discussed and the implications of corrosion on the structures are explored. From the results obtained, it is possible to see how the use of different techniques for strengthening and passive seismic protection strategy can allow engineers to obtain the result of structural adaptation to earthquakes with low-cost interventions. The widespread adoption of steel jackets, coupled with the construction of floors using a steel–concrete composite structure, grants a good confinement of the beam–column r.c. joints, together with the overall strengthening of the existing structure. The adoption of CFRP wrapping at the lower edge of the beams implies a limited increase in thickness and the limited interventions of partial demolition from the existing structural members. A critical review of the steel jacketing aspects in terms of bending and shear strengthening is reported by considering this technique in the form of a steel exoskeleton containing the damaged concrete structure, by confining concrete elements, and by increasing the performance for both gravitational and seismic loads. Full article
Show Figures

Figure 1

19 pages, 4269 KB  
Article
Flexural Performance of Cracked Reinforced Concrete Beams Strengthened with Prestressed CFRP Sheets under Repeated Loads
by Huijuan Wang, Changyong Li, Sihao Song, Yao Wang, Qingxin Meng and Fenglan Li
Buildings 2023, 13(8), 2115; https://doi.org/10.3390/buildings13082115 - 21 Aug 2023
Cited by 10 | Viewed by 3240
Abstract
Because researchers are aiming to restore the deformation and minimize the crack width of existing concrete structures, the strengthening technology of prestressed carbon-fiber-reinforced plastic (CFRP) is currently the focus of many studies and applications. In terms of the strengthening of a prestressed CFRP [...] Read more.
Because researchers are aiming to restore the deformation and minimize the crack width of existing concrete structures, the strengthening technology of prestressed carbon-fiber-reinforced plastic (CFRP) is currently the focus of many studies and applications. In terms of the strengthening of a prestressed CFRP sheet on the flexural performance of cracked reinforced concrete beams under repeated loads, a four-point bending test of 12 beams was conducted considering the prestress degree reflected by the amount and the prestress force of the CFRP sheet. The longitudinal strengthened CFRP sheet was bonded on the bottom surface of the test beam and fixed by U-jacket CFRP sheets at the ends after tensioning. The strains of concrete, longitudinal tensile steel bars and CFRP sheets were measured at the pure bending segment of test beams, while the cracks, midspan deflection and failure pattern were recorded. The results show that the normal strain on the mid-span section of the strengthened beams by the prestress CFRP sheets was fitted for the assumption of plane section, the cracks and mid-span deflection decreased with the prestress degree of the CFRP sheets to provide better serviceability for the strengthened beams, the load capacity could be increased by 41.0–88.8% at the yield of longitudinal tensile steel bars and increased by 41.9–74.8% at the ultimate state and the ductility at the failure state was sharply reduced by 54.9–186%. The peeling off of broken CFRP sheets played a role in controlling the failure pattern of the strengthened beams under repeated loads. Finally, methods for predicting the bending performance of reinforced concrete beams strengthened by prestressed CFRP sheets were proposed. This study enriches the knowledge about damaged reinforced concrete beams that were strengthened with prestressed CFRP sheets. Full article
(This article belongs to the Special Issue Recent Advances in Structural Engineering)
Show Figures

Figure 1

Back to TopTop