Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (45)

Search Parameters:
Keywords = automatic optimal sensor selection algorithm

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
17 pages, 2601 KB  
Article
High-Precision Insulation Monitoring-Driven Intelligent Fault Line Selection Method for Photovoltaic DC Grounding Faults
by Binyao Lu and Xiangning Lin
Energies 2026, 19(16), 3918; https://doi.org/10.3390/en19163918 - 20 Aug 2026
Viewed by 223
Abstract
Currently, insulation faults in the DC system of photovoltaic (PV) power stations are handled by a full shutdown strategy of inverters, and fault branch localization relies on manual inspection, resulting in low efficiency and poor accuracy, leading to prolonged unplanned outages and substantial [...] Read more.
Currently, insulation faults in the DC system of photovoltaic (PV) power stations are handled by a full shutdown strategy of inverters, and fault branch localization relies on manual inspection, resulting in low efficiency and poor accuracy, leading to prolonged unplanned outages and substantial power generation losses. This paper proposes an integrated solution combining high-precision insulation monitoring and intelligent fault line selection, which ensures the reliability of line selection criteria through improved measurement accuracy and achieves automatic fault isolation via optimized line selection strategies. The paper analyzes the mathematical essence of the ill-conditioned measurement equations of the traditional bridge method under severe single-pole grounding faults, establishes a dual-channel heteroscedastic noise model, and utilizes the inherent physical constraint that the sum of the positive and negative pole-to-ground voltages always equals the bus voltage to transform the ill-posed inverse problem into an equality-constrained optimal estimation problem, deriving an analytical solution in the sense of constrained least squares. A collaborative monitoring strategy of “balanced bridge monitoring first, unbalanced bridge precision measurement afterward” is proposed. An automatic fault line selection and isolation algorithm based on sequential branch switching is designed, which leverages the operational characteristic that PV systems allow short-term branch interruption, enabling automatic identification and isolation of faulty branches and automatic restoration of non-faulty branches without installing any leakage current sensors. Experimental results show that under severe fault conditions with a single-pole insulation resistance as low as 22 kΩ, the proposed method limits the error to within 5%; the proposed line selection strategy can complete identification and isolation of all faulty branches within at most two rounds of switching. Full article
(This article belongs to the Section F1: Electrical Power System)
Show Figures

Figure 1

21 pages, 6351 KB  
Article
Preliminary Research on Autonomous Robotic System for DDH Ultrasound Examination 
by Jianwei Cui, Yuxiang Dai, Xinyu Zhang, Yao Xiong and Wenyi Zhang
Actuators 2026, 15(8), 446; https://doi.org/10.3390/act15080446 - 16 Aug 2026
Viewed by 203
Abstract
Ultrasound examination for developmental dysplasia of the hip (DDH) in infants is highly dependent on operator experience, leading to inconsistent imaging quality and poor reproducibility between sonographers. This study proposes an autonomous robotic ultrasound system to improve the standardization and automation of hip [...] Read more.
Ultrasound examination for developmental dysplasia of the hip (DDH) in infants is highly dependent on operator experience, leading to inconsistent imaging quality and poor reproducibility between sonographers. This study proposes an autonomous robotic ultrasound system to improve the standardization and automation of hip ultrasound examinations. The system consists of a robotic arm, a six-axis force/torque sensor, an RGB-D camera and an ultrasound probe, integrating multiple functions including contact force control, visual localization, deep-learning-based segmentation and ultrasound image screening. To ensure stability and safety during scanning, an admittance-based hybrid force/position control strategy is adopted to achieve constant contact force control. For Graf standard plane acquisition, a stage-wise search strategy is designed, in which the search space is progressively narrowed through femoral head searching and multi-angle scanning. The optimal Graf standard plane is then automatically selected by combining image segmentation with a scoring mechanism. A customized hip phantom was used for validation. Experimental results show that the Dice coefficient for femoral head segmentation reaches 0.872, while the average Dice coefficient for multi-structure segmentation reaches 0.866. In 30 autonomous scanning trials, the success rate of Graf standard plane acquisition is 90.0%. Meanwhile, the system can maintain the contact force stably within the target range during scanning, validating the effectiveness of the force control strategy. These results indicate that the proposed robotic system, image recognition algorithm and visual servo control strategy exhibit favorable safety and feasibility, providing an innovative solution for automated infant hip ultrasound examination of DDH. Full article
(This article belongs to the Section Actuators for Robotics)
Show Figures

Figure 1

23 pages, 9341 KB  
Article
Landsat Imagery Built-Up Area Extraction Method with Use of Multiple Indexes and Tasseled Cap Transformation
by Juan Gu, Peng Dou, Chunlin Huang, Jinliang Hou, Ying Zhang, Weixiao Han and Jifu Guo
Remote Sens. 2026, 18(11), 1721; https://doi.org/10.3390/rs18111721 - 27 May 2026
Viewed by 453
Abstract
Built-up area extraction is important for monitoring urban development and land-use change. Index-based methods are widely used for extracting built-up areas from Landsat imagery because of their simplicity and efficiency. However, conventional built-up indices often enhance bare land together with built-up areas due [...] Read more.
Built-up area extraction is important for monitoring urban development and land-use change. Index-based methods are widely used for extracting built-up areas from Landsat imagery because of their simplicity and efficiency. However, conventional built-up indices often enhance bare land together with built-up areas due to their similar spectral characteristics, which reduces extraction accuracy and limits automatic threshold selection. To address this problem, this study proposes a built-up area extraction method based on multi-index synthesis and principal component analysis (PCA). First, NDBI (Normalization Differential Building Index), SAVI (Soil-Adjusted Vegetation Index), MNDWI (Modified Normalized Difference Water Index), and the brightness, greenness, and wetness components of the Tasseled Cap transformation were stacked to construct a six-band synthetic index image, enhancing the contrast among built-up areas, bare land, vegetation, and water bodies. PCA was then applied to the synthetic image using both correlation and covariance matrices, and the second principal component was used to enhance built-up area information. The resulting CorPC2 and CovPC2 methods were evaluated and compared with conventional built-up indices. The results showed that both PC2-based methods improved the separability between built-up areas and background features, while CovPC2 achieved the best performance by more effectively suppressing bare-land interference without requiring an additional bare-land mask. In the main experimental area, CovPC2 achieved higher accuracy than the comparison methods, and its Otsu-based result remained close to the optimal-threshold result. Validation in three typical cities further demonstrated the applicability of the proposed method across different Landsat sensors and urban environments. The proposed PC2-based method, particularly CovPC2, provides an effective and more automated approach for Landsat-based built-up area extraction under bare-land interference. Additionally, by using a threshold optimizing algorithm, built-up areas can be automatically extracted with high accuracy. Full article
Show Figures

Figure 1

18 pages, 3852 KB  
Article
A Field Verification Denoising Method for Partial Discharge Ultrasonic Sensors Based on IPSO-Optimated Multivariate Variational Mode Decomposition Combined with Improved Wavelet Transforms
by Tienan Cao, Yufei Cui, Haotian Tan, Wei Lu, Fuzeng Zhang, Kai Liu, Xiaoguo Chen, Yifan Chen and Lujia Wang
Sensors 2025, 25(24), 7506; https://doi.org/10.3390/s25247506 - 10 Dec 2025
Cited by 2 | Viewed by 851
Abstract
Field verification of contact-type ultrasonic sensors enables rapid evaluation of their sensitivity performance, thereby ensuring the accuracy of partial discharge (PD) ultrasonic monitoring results. However, during the verification process, both the standard sensor and the sensor under testing are inevitably affected by ambient [...] Read more.
Field verification of contact-type ultrasonic sensors enables rapid evaluation of their sensitivity performance, thereby ensuring the accuracy of partial discharge (PD) ultrasonic monitoring results. However, during the verification process, both the standard sensor and the sensor under testing are inevitably affected by ambient noise when receiving verification signals, which can result in significant errors in the verification outcome. To address this issue, a noise suppression method is proposed in this study, which integrates multivariate variational mode decomposition (MVMD) optimized by an improved particle swarm optimization (IPSO) algorithm with a hyperbolic tangent-modulated exponential decay wavelet thresholding technique. First, the IPSO algorithm is employed to automatically optimize the parameters of MVMD. Then, the dominant components of the verification signal are selected based on the energy entropy of each decomposed mode. Subsequently, a novel wavelet threshold function incorporating hyperbolic tangent modulation and exponential decay is constructed and combined with an improved thresholding strategy to denoise the residual noise in the dominant components. Finally, a verification platform based on a real-type transformer is established. Both simulated and measured signals are denoised and subjected to sensitivity verification using the proposed method. Comparative analysis with noise-affected verification results demonstrates that the proposed method effectively suppresses noise in the verification signals and improves the accuracy of the sensitivity verification. Full article
Show Figures

Figure 1

26 pages, 2755 KB  
Article
Fault Diagnosis Method for High-Voltage Direct Current Transmission System Based on Multimodal Sensor Feature-LightGBM Algorithm: A Case Study in China
by Qiang Li, Yingfei Li, Shihong Zhang, Yue Ma, Yinan Qiu, Xiaohang Luo and Bo Yang
Energies 2025, 18(23), 6253; https://doi.org/10.3390/en18236253 - 28 Nov 2025
Cited by 1 | Viewed by 869
Abstract
To improve/enhance the intelligence and accuracy of fault diagnosis in high-voltage direct current (HVDC) systems, this paper proposes a fault diagnosis model for HVDC systems based on the multimodal sensor feature-light gradient boosting machine (MSF-LightGBM) algorithm. First, a sample set encompassing four typical [...] Read more.
To improve/enhance the intelligence and accuracy of fault diagnosis in high-voltage direct current (HVDC) systems, this paper proposes a fault diagnosis model for HVDC systems based on the multimodal sensor feature-light gradient boosting machine (MSF-LightGBM) algorithm. First, a sample set encompassing four typical types of faults, namely alternating current (AC) faults, direct current (DC) faults, inverter commutation failures, and converter valve faults, was constructed based on the actual HVDC transmission data from China. Second, considering the issues of imbalanced sample classes and a relatively small sample size in the original dataset, a data augmentation method incorporating multiple types of noise is introduced to improve the diversity and practical representativeness of the samples. Then, time-series features in the time domain, frequency domain, and wavelet domain, along with Pearson correlation features among 15 sensors, are extracted to form a comprehensive feature vector. On this basis, automatic feature selection is performed using recursive feature elimination (RFE) to screen out the key features. Finally, the paper builds an optimized LightGBM classification model is built using the key features. Through comparative experiments with five machine learning methods, the results indicate that the accuracy of the proposed method on the test set reaches 0.9583, significantly outperforming the other comparison models. The receiver operating characteristic (ROC) curve analysis reveals that the average area under the curve (AUC) for all four types of faults is 0.975, validating the stability and accuracy of the proposed model in multi-class fault identification. Full article
(This article belongs to the Special Issue Energy, Electrical and Power Engineering: 5th Edition)
Show Figures

Figure 1

21 pages, 4777 KB  
Article
Processing the Sensor Signal in a PI Control System Using an Adaptive Filter Based on Fuzzy Logic
by Jarosław Joostberens, Aurelia Rybak and Aleksandra Rybak
Symmetry 2025, 17(10), 1774; https://doi.org/10.3390/sym17101774 - 21 Oct 2025
Cited by 1 | Viewed by 711
Abstract
This paper presents an adaptive fuzzy filter applied to processing a signal from a voltage sensor fed to the input of an object in an automatic temperature control system with a PI controller. (1) The research goal was to develop an algorithm for [...] Read more.
This paper presents an adaptive fuzzy filter applied to processing a signal from a voltage sensor fed to the input of an object in an automatic temperature control system with a PI controller. (1) The research goal was to develop an algorithm for processing the signal from an RMS voltage sensor, measured at the terminals of a heating element in a temperature control system with a PI controller, in a way that ensures good dynamic properties while maintaining an appropriate level of accuracy. (2) The paper presents a method for designing an adaptive fuzzy filter by synthesizing a first-order low-pass infinite impulse response (IIR) filter and a fuzzy model of the dependence of this filter parameter value on the modulus of the derivative of the measured quantity. The application of a model with a symmetric input and output structure and a modified fuzzy model with asymmetry resulting from the uneven distribution of modal values of singleton fuzzy sets at the output was shown. The innovation in the proposed solution is the use of a signal from a PI controller to determine the derivative module of the measured quantity and, using a fuzzy model, linking its instantaneous value with a digital filter parameter in the measurement chain with a sensor monitoring the signal at the input of the controlled object. It is demonstrated that the signal generated by the PI controller can be used in a control system to continuously determine the modulus of the time derivative of the signal measured at the input of the controlled object, also indicating the limitations of this method. The signal from the PI controller can also be used to select filter parameters. In such a situation, it can be treated as a reference signal representing the useful signal. The mean square error (MSE) was adopted as the criterion for matching the signal at the filter output to the reference signal. (3) Based on a comparative analysis of the results of using an adaptive fuzzy filter with a classic first-order IIR filter with an optimal parameter in the MSE sense, it was found that using a fuzzy filter yields better results, regardless of the structure of the fuzzy model used (symmetric or asymmetric). (4) The paper demonstrates that in the tested temperature control system, introducing a simple fuzzy model with one input characterized by three fuzzy sets, relating the modulus of the derivative of the signal developed by the PI controller to the value of the first-order IIR filter parameter, into the voltage sensor signal-processing algorithm gave significantly better results than using a first-order IIR filter with a constant optimal parameter in terms of MSE. The best results were obtained using a fuzzy model in which an intentional asymmetry in the modal values of the output fuzzy sets was introduced. Full article
(This article belongs to the Special Issue Symmetry/Asymmetry in Fuzzy Control)
Show Figures

Figure 1

20 pages, 6308 KB  
Article
An Intelligent Algorithm for the Optimal Deployment of Water Network Monitoring Sensors Based on Automatic Labelling and Graph Neural Network
by Guoxin Shi, Xianpeng Wang, Jingjing Zhang and Xinlei Gao
Information 2025, 16(10), 837; https://doi.org/10.3390/info16100837 - 27 Sep 2025
Cited by 1 | Viewed by 1008
Abstract
In order to enhance leakage detection accuracy in water distribution networks (WDNs) while reducing sensor deployment costs, an intelligent algorithm for the optimal deployment of water network monitoring sensors based on the automatic labelling and graph neural network (ALGN) was proposed for the [...] Read more.
In order to enhance leakage detection accuracy in water distribution networks (WDNs) while reducing sensor deployment costs, an intelligent algorithm for the optimal deployment of water network monitoring sensors based on the automatic labelling and graph neural network (ALGN) was proposed for the optimal deployment of WDN monitoring sensors. The research aims to develop a data-driven, topology-aware sensor deployment strategy that achieves high leakage detection performance with minimal hardware requirements. The methodology consisted of three main steps: first, the dung beetle optimization algorithm (DBO) was employed to automatically determine optimal parameters for the DBSCAN clustering algorithm, which generated initial cluster labels; second, a customized graph neural network architecture was used to perform topology-aware node clustering, integrating network structure information; finally, optimal pressure sensor locations were selected based on minimum distance criteria within identified clusters. The key innovation lies in the integration of metaheuristic optimization with graph-based learning to fully automate the sensor placement process while explicitly incorporating the hydraulic network topology. The proposed approach was validated on real-world WDN infrastructure, demonstrating superior performance with 93% node coverage and 99.77% leakage detection accuracy, surpassing state-of-the-art methods by 2% and 0.7%, respectively. These results indicate that the ALGN framework provides municipal water utilities with a robust, automated solution for designing efficient pressure monitoring systems that balance detection performance with implementation cost. Full article
Show Figures

Figure 1

33 pages, 20725 KB  
Article
Data Quality, Semantics, and Classification Features: Assessment and Optimization of Supervised ML-AI Classification Approaches for Historical Heritage
by Valeria Cera, Giuseppe Antuono, Massimiliano Campi and Pierpaolo D’Agostino
Heritage 2025, 8(7), 265; https://doi.org/10.3390/heritage8070265 - 4 Jul 2025
Cited by 2 | Viewed by 1469
Abstract
In recent years, automatic segmentation and classification of data from digital surveys have taken a central role in built heritage studies. However, the application of Machine and Deep Learning (ML and DL) techniques for semantic segmentation of point clouds is complex in the [...] Read more.
In recent years, automatic segmentation and classification of data from digital surveys have taken a central role in built heritage studies. However, the application of Machine and Deep Learning (ML and DL) techniques for semantic segmentation of point clouds is complex in the context of historic architecture because it is characterized by high geometric and semantic variability. Data quality, subjectivity in manual labeling, and difficulty in defining consistent categories may compromise the effectiveness and reproducibility of the results. This study analyzes the influence of three key factors—annotator specialization, point cloud density, and sensor type—in the supervised classification of architectural elements by applying the Random Forest (RF) algorithm to datasets related to the architectural typology of the Franciscan cloister. The main innovation of the study lies in the development of an advanced feature selection technique, based on multibeam statistical analysis and evaluation of the p-value of each feature with respect to the target classes. The procedure makes it possible to identify the optimal radius for each feature, maximizing separability between classes and reducing semantic ambiguities. The approach, entirely in Python, automates the process of feature extraction, selection, and application, improving semantic consistency and classification accuracy. Full article
Show Figures

Figure 1

23 pages, 12272 KB  
Article
Optimized Design and Deep Vision-Based Operation Control of a Multi-Functional Robotic Gripper for an Automatic Loading System
by Yaohui Wang, Sheng Guo, Jinliang Zhang, Hongbo Ding, Bo Zhang, Ao Cao, Xiaohu Sun, Guangxin Zhang, Shihe Tian, Yongxu Chen, Jixuan Ma and Guangrong Chen
Actuators 2025, 14(6), 259; https://doi.org/10.3390/act14060259 - 23 May 2025
Cited by 3 | Viewed by 1595
Abstract
This study presents an optimized design and vision-guided control strategy for a multi-functional robotic gripper integrated into an automatic loading system for warehouse environments. The system adopts a modular architecture, including standardized platforms, transport containers, four collaborative 6-DOF robotic arms, and a multi-sensor [...] Read more.
This study presents an optimized design and vision-guided control strategy for a multi-functional robotic gripper integrated into an automatic loading system for warehouse environments. The system adopts a modular architecture, including standardized platforms, transport containers, four collaborative 6-DOF robotic arms, and a multi-sensor vision module. Methodologically, we first developed three gripper prototypes, selecting the optimal design (30° angle between the gripper and container side) through workspace and interference analysis. A deep vision-based recognition system, enhanced by an improved YOLOv5 algorithm and multi-feature fusion, was employed for real-time object detection and pose estimation. Kinematic modeling and seventh-order polynomial trajectory planning ensured smooth and precise robotic arm movements. Key results from simulations and experiments demonstrated a 95.72% success rate in twist lock operations, with a positioning accuracy of 1.2 mm. The system achieved a control cycle of 35 ms, ensuring efficiency compared with non-vision-based methods. Practical implications include enabling fully autonomous container handling in logistics, reducing labor costs, and enhancing operational safety. Limitations include dependency on fixed camera setups and sensitivity to extreme lighting conditions. Full article
Show Figures

Figure 1

17 pages, 399 KB  
Article
Energy Distribution Optimization in Heterogeneous Networks with Min–Max and Local Constraints as Support of Ambient Intelligence
by Alessandro Aloisio, Domenico D. Bloisi, Marco Romano and Cosimo Vinci
Sensors 2025, 25(9), 2721; https://doi.org/10.3390/s25092721 - 25 Apr 2025
Cited by 2 | Viewed by 940
Abstract
In recent years, ambient intelligence (AmI) has gained significant attention from both academia and industry. AmI seeks to create environments that automatically adapt to individuals’ needs, improving comfort and efficiency. These systems typically rely on Internet of Things (IoT) frameworks, where sensors and [...] Read more.
In recent years, ambient intelligence (AmI) has gained significant attention from both academia and industry. AmI seeks to create environments that automatically adapt to individuals’ needs, improving comfort and efficiency. These systems typically rely on Internet of Things (IoT) frameworks, where sensors and actuators enable seamless interaction between people and their surroundings. To ensure the effective operation of AmI systems, robust wireless networks are essential, capable of integrating a wide range of devices across different environments. However, designing such networks presents challenges due to varying communication protocols, power limitations, and the computational capacities of connected devices. This paper introduces a novel approach that leverages multi-interface networks to design a heterogeneous wireless network supporting AmI systems within the IoT ecosystem. The approach centers on selecting the most appropriate communication protocols, such as Wi-Fi, Bluetooth, or 5G, to connect devices. Since many devices are battery-powered, choosing the right communication interface is critical for optimizing energy efficiency. Our primary objective is to improve network performance while extending its operational lifespan by identifying an optimal set of interfaces that balance power consumption and efficiency. We present a new model within the well-established field of multi-interface networks, designed to reduce battery consumption while maximizing network performance. Additionally, we examine the computational complexity of this model and propose two solution algorithms grounded in fixed-parameter tractability theory for specific network classes. Full article
(This article belongs to the Section Internet of Things)
Show Figures

Figure 1

21 pages, 3699 KB  
Article
A Distributed RF Threat Sensing Architecture
by Georgios Michalis, Andreas Rousias, Loizos Kanaris, Akis Kokkinis , Pantelis Kanaris  and Stavros Stavrou
Information 2024, 15(12), 752; https://doi.org/10.3390/info15120752 - 26 Nov 2024
Viewed by 2868
Abstract
The scope of this work is to propose a distributed RF sensing architecture that interconnects and utilizes a cyber security operations center (SOC) to support long-term RF threat monitoring, alerting, and further centralized processing. For the purpose of this work, RF threats refer [...] Read more.
The scope of this work is to propose a distributed RF sensing architecture that interconnects and utilizes a cyber security operations center (SOC) to support long-term RF threat monitoring, alerting, and further centralized processing. For the purpose of this work, RF threats refer mainly to RF jamming, since this can jeopardize multiple wireless systems, either directly as a Denial of Service (DoS) attack, or as a means to force a cellular or WiFi wireless client to connect to a malicious system. Furthermore, the possibility of the suggested architecture to monitor signals from malicious drones in short distances is also examined. The work proposes, develops, and examines the performance of RF sensing sensors that can monitor any frequency band within the range of 1 MHz to 8 GHz, through selective band pass RF filtering, and subsequently these sensors are connected to a remote SOC. The proposed sensors incorporate an automatic calibration and time-depended environment RF profiling algorithm and procedure for optimizing RF jamming detection in a dense RF spectrum, occupied by heterogeneous RF technologies, thus minimizing false-positive alerts. The overall architecture supports TCP/IP interconnections of multiple RF jamming detection sensors through an efficient MQTT protocol, allowing the collaborative operation of sensors that are distributed in different areas of interest, depending on the scenario of interest, offering holistic monitoring by the centralized SOC. The incorporation of the centralized SOC in the overall architecture allows also the centralized application of machine learning algorithms on all the received data. Full article
(This article belongs to the Special Issue Emerging Information Technologies in the Field of Cyber Defense)
Show Figures

Figure 1

17 pages, 8979 KB  
Article
Determining the Optimal Window Duration to Enhance Emotion Recognition Based on Galvanic Skin Response and Photoplethysmography Signals
by Marcos F. Bamonte, Marcelo Risk and Victor Herrero
Electronics 2024, 13(16), 3333; https://doi.org/10.3390/electronics13163333 - 22 Aug 2024
Cited by 8 | Viewed by 3127
Abstract
Automatic emotion recognition using portable sensors is gaining attention due to its potential use in real-life scenarios. Existing studies have not explored Galvanic Skin Response and Photoplethysmography sensors exclusively for emotion recognition using nonlinear features with machine learning (ML) classifiers such as Random [...] Read more.
Automatic emotion recognition using portable sensors is gaining attention due to its potential use in real-life scenarios. Existing studies have not explored Galvanic Skin Response and Photoplethysmography sensors exclusively for emotion recognition using nonlinear features with machine learning (ML) classifiers such as Random Forest, Support Vector Machine, Gradient Boosting Machine, K-Nearest Neighbor, and Decision Tree. In this study, we proposed a genuine window sensitivity analysis on a continuous annotation dataset to determine the window duration and percentage of overlap that optimize the classification performance using ML algorithms and nonlinear features, namely, Lyapunov Exponent, Approximate Entropy, and Poincaré indices. We found an optimum window duration of 3 s with 50% overlap and achieved accuracies of 0.75 and 0.74 for both arousal and valence, respectively. In addition, we proposed a Strong Labeling Scheme that kept only the extreme values of the labels, which raised the accuracy score to 0.94 for arousal. Under certain conditions mentioned, traditional ML models offer a good compromise between performance and low computational cost. Our results suggest that well-known ML algorithms can still contribute to the field of emotion recognition, provided that window duration, overlap percentage, and nonlinear features are carefully selected. Full article
Show Figures

Figure 1

21 pages, 2285 KB  
Article
An Efficient Approach for Automatic Fault Classification Based on Data Balance and One-Dimensional Deep Learning
by Ugur Ileri, Yusuf Altun and Ali Narin
Appl. Sci. 2024, 14(11), 4899; https://doi.org/10.3390/app14114899 - 5 Jun 2024
Cited by 7 | Viewed by 3505
Abstract
Predictive maintenance (PdM) is implemented to efficiently manage maintenance schedules of machinery and equipment in manufacturing by predicting potential faults with advanced technologies such as sensors, data analysis, and machine learning algorithms. This paper introduces a study of different methodologies for automatically classifying [...] Read more.
Predictive maintenance (PdM) is implemented to efficiently manage maintenance schedules of machinery and equipment in manufacturing by predicting potential faults with advanced technologies such as sensors, data analysis, and machine learning algorithms. This paper introduces a study of different methodologies for automatically classifying the failures in PdM data. We first present the performance evaluation of fault classification performed by shallow machine learning (SML) methods such as Decision Trees, Support Vector Machines, k-Nearest Neighbors, and one-dimensional deep learning (DL) techniques like 1D-LeNet, 1D-AlexNet, and 1D-VGG16. Then, we apply normalization, which is a scaling technique in which features are shifted and rescaled in the dataset. We reapply classification algorithms to the normalized dataset and present the performance tables in comparison with the first results we obtained. Moreover, in contrast to existing studies in the literature, we generate balanced dataset groups by randomly selecting normal data and all faulty data for all fault types from the original dataset. The dataset groups are generated with 100 different repetitions, recording performance scores for each one and presenting the maximum scores. All methods utilized in the study are similarly employed on these groups. From these scores, the use of 1D-LeNet deep learning classifiers and feature normalization resulted in achieving the highest overall accuracy and F1-score performance of 98.50% and 98.32%, respectively. As a result, the goal of this study was to develop an efficient approach for automatic fault classification, leveraging data balance, and additionally, to provide an analysis of one-dimensional deep learning and shallow machine learning-based classification methods. In light of the experimentation and comparative analysis, this study successfully achieves its stated goal by demonstrating that one-dimensional deep learning and data balance collectively emerge as the optimal approach, offering good prediction accuracy. Full article
Show Figures

Figure 1

27 pages, 15877 KB  
Article
The Performance of Landsat-8 and Landsat-9 Data for Water Body Extraction Based on Various Water Indices: A Comparative Analysis
by Jie Chen, Yankun Wang, Jingzhe Wang, Yinghui Zhang, Yue Xu, Ou Yang, Rui Zhang, Jing Wang, Zhensheng Wang, Feidong Lu and Zhongwen Hu
Remote Sens. 2024, 16(11), 1984; https://doi.org/10.3390/rs16111984 - 31 May 2024
Cited by 44 | Viewed by 9098
Abstract
The rapid and accurate extraction of water information from satellite imagery has been a crucial topic in remote sensing applications and has important value in water resources management, water environment monitoring, and disaster emergency management. Although the OLI-2 sensor onboard Landsat-9 is similar [...] Read more.
The rapid and accurate extraction of water information from satellite imagery has been a crucial topic in remote sensing applications and has important value in water resources management, water environment monitoring, and disaster emergency management. Although the OLI-2 sensor onboard Landsat-9 is similar to the well-known OLI onboard Landsat-8, there were significant differences in the average absolute percentage change in the bands for water detection. Additionally, the performance of Landsat-9 in water body extraction is yet to be fully understood. Therefore, it is crucial to conduct comparative studies to evaluate the water extraction performance of Landsat-9 with Landsat-8. In this study, we analyze the performance of simultaneous Landsat-8 and Landsat-9 data for water body extraction based on eight common water indices (Normalized Difference Water Index (NDWI) and Modified Normalized Difference Water Index (MNDWI), Augmented Normalized Difference Water Index (ANDWI), Water Index 2015 (WI2015), tasseled cap wetness index (TCW), Automated Water Extraction Index for scenes with shadows (AWEIsh) and without shadows (AWEInsh) and Multi-Band Water Index (MBWI)) to extract water bodies in seven study sites worldwide. The Otsu algorithm is utilized to automatically determine the optimal segmentation threshold for water body extraction. The results showed that (1) Landsat-9 satellite data can be used for water body extraction effectively, with results consistent with those from Landsat-8. The eight selected water indices in this study are applicable to both Landsat-8 and Landsat-9 satellites. (2) The NDWI index shows a larger variability in accuracy compared to other indices when used on Landsat-8 and Landsat-9 imagery. Therefore, additional caution should be exercised when using the NDWI for water body analysis with both Landsat-8 and Landsat-9 satellites simultaneously. (3) For Landsat-8 and Landsat-9 imagery, ratio-based water indices tend to have more omission errors, while difference-based indices are more prone to commission errors. Overall, ratio-based indices exhibit greater variability in overall accuracy, whereas difference-based indices demonstrate lower sensitivity to variations in the study area, showing smaller overall accuracy fluctuations and higher robustness. This study can provide necessary references for the selection of water indices based on the newest Landsat-9 data. The results are crucial for guiding the combined use of Landsat-8 and Landsat-9 for global surface water mapping and understanding its long-term changes. Full article
Show Figures

Figure 1

25 pages, 8576 KB  
Article
Fault Diagnosis of Hydraulic Components Based on Multi-Sensor Information Fusion Using Improved TSO-CNN-BiLSTM
by Da Zhang, Kun Zheng, Fuqi Liu and Beili Li
Sensors 2024, 24(8), 2661; https://doi.org/10.3390/s24082661 - 22 Apr 2024
Cited by 8 | Viewed by 3093
Abstract
In order to realize the accurate and reliable fault diagnosis of hydraulic systems, a diagnostic model based on improved tuna swarm optimization (ITSO), optimized convolutional neural networks (CNNs), and bi-directional long short-term memory (BiLSTM) networks is proposed. Firstly, sensor selection is implemented using [...] Read more.
In order to realize the accurate and reliable fault diagnosis of hydraulic systems, a diagnostic model based on improved tuna swarm optimization (ITSO), optimized convolutional neural networks (CNNs), and bi-directional long short-term memory (BiLSTM) networks is proposed. Firstly, sensor selection is implemented using the random forest algorithm to select useful signals from six kinds of physical or virtual sensors including pressure, temperature, flow rate, vibration, motor power, and motor efficiency coefficient. After that, fused features are extracted by CNN, and then, BiLSTM is applied to learn the forward and backward information contained in the data. The ITSO algorithm is adopted to adaptively optimize the learning rate, regularization coefficient, and node number to obtain the optimal CNN-BiLSTM network. Improved Chebyshev chaotic mapping and the nonlinear reduction strategy are adopted to improve population initialization and individual position updating, further promoting the optimization effect of TSO. The experimental results show that the proposed method can automatically extract fusion features and effectively utilize multi-sensor information. The diagnostic accuracies of the plunger pump, cooler, throttle valve, and accumulator are 99.07%, 99.4%, 98.81%, and 98.51%, respectively. The diagnostic results of noisy data with 0 dB, 5 dB, and 10 dB signal-to-noise ratios (SNRs) show that the ITSO-CNN-BiLSTM model has good robustness to noise interference. Full article
(This article belongs to the Section Fault Diagnosis & Sensors)
Show Figures

Figure 1

Back to TopTop