We propose the use of a specially designed polyurethane foam with a plateau region in its mechanical characteristics—where stress remains nearly constant during deformation—between the electromyography (EMG) electrode and clothing to supp...
We propose the use of a specially designed polyurethane foam with a plateau region in its mechanical characteristics—where stress remains nearly constant during deformation—between the electromyography (EMG) electrode and clothing to supp...
Electromyography (EMG) devices are well-suited for measuring the behaviour of muscles during an exercise or a task, and are widely used in many different research areas. Their disadvantage is that commercial systems are expensive. We designed a low-c...
15 June 2021
Gait impairment often limits physical activity and negatively impacts quality of life. EMG-Biofeedback (EMG-BFB), one of the more effective interventions for improving gait impairment, has been limited to laboratory use due to system costs and techni...
Background and Objectives: While shoulder injuries represent the musculoskeletal disorders (MSDs) most encountered in physical therapy, there is no consensus on their management. In attempts to provide standardized and personalized treatment, a robot...
There is a lack of research in using electromyography (EMG) signals to control a continuous passive motion (CPM) machine. This study aimed to develop an interface instrument for digitalising EMG signals and controlling a CPM machine. Methods: The pro...
Wearable devices based on surface electromyography (sEMG) to detect muscle activity can be used to assess muscle strength with the development of hand rehabilitation applications. However, conventional acquisition devices are usually complicated to o...
Electromyography (EMG) stands out as an accessible and inexpensive method for identifying muscle contractions on the surface and within deeper muscle tissues. Using specialized electronic circuits for amplification and filtering can help develop simp...
Purpose: The aim of this study was to assess within-session reliability and concurrent validity of a wireless surface electromyography device (MR EMG) relative to a wireless criterion system (Delsys Trigno) during dynamic leg extension at varying loa...
Wearable surface electromyography (sEMG) signal-acquisition devices have considerable potential for medical applications. Signals obtained from sEMG armbands can be used to identify a person’s intentions using machine learning. However, the per...
In recent years, the surface electromyography (EMG) signal has received a lot of attention. EMG signals are used to analyze muscle activity or to evaluate a patient’s muscle status. However, commercial surface EMG systems are expensive and have high...
Demand for interactive wearable devices is rapidly increasing with the development of smart devices. To accurately utilize wearable devices for remote robot controls, limited data should be analyzed and utilized efficiently. For example, the motions...
The acquisition of physiological data are essential to efficiently predict and treat cardiac patients before a heart attack occurs and effectively expedite motor recovery after a stroke. This goal can be achieved by using wearable wireless sensor net...
Background: Overground Robot-Assisted Gait Training (o-RAGT) appears to be a promising stroke rehabilitation in terms of clinical outcomes. The literature on surface ElectroMyoGraphy (sEMG) assessment in o-RAGT is limited. This paper aimed to assess...
User authentication has traditionally been performed using methods such as passwords or fingerprints. However, passwords have security vulnerabilities, and fingerprints may hinder user convenience. To address these issues, a novel user authentication...
Secondary injuries are common during upper limb rehabilitation training because of uncontrollable physical force and overexciting activities, and long-time training may cause fatigue and reduce the training effect. This study proposes a wearable moni...
Chewing is essential in regulating metabolism and initiating digestion. Various methods have been used to examine chewing, including analyzing chewing sounds and using piezoelectric sensors to detect muscle contractions. However, these methods strugg...
Wearable robotic braces have the potential to improve rehabilitative therapies for patients suffering from musculoskeletal (MSK) conditions. Ideally, a quantitative assessment of health would be incorporated into rehabilitative devices to monitor pat...
Electromyography (EMG)-controlled orthoses and wearable assistive systems require classifiers that combine accurate motion recognition, efficient embedded deployment, and support for local model formation. Long-term EMG deployment is affected by sign...
As the number of patients with amputations increases, research on assistive devices such as prosthetic limbs is actively being conducted. However, the development of assistive devices for patients with partial amputations is insufficient. In this stu...
Tiny Machine Learning (TinyML) promises always-on surface electromyography (sEMG) sensing that runs entirely on microcontrollers. How much of the published work actually delivers on-device inference is far less clear. We examined that question across...
Analyzing the dynamics of muscle activation patterns and joint range of motion is essential to understanding human movement during complex tasks such as tooth brushing Activities of Daily Living (ADLs). In individuals with neuromotor impairments, acc...
The design and control of artificial hands remains a challenge in engineering. Popular prostheses are bio-mechanically simple with restricted manipulation capabilities, as advanced devices are pricy or abandoned due to their difficult communication w...
Gait phase recognition systems based on surface electromyographic signals (EMGs) are crucial for developing advanced myoelectric control schemes that enhance the interaction between humans and lower limb assistive devices. However, machine learning m...
29 November 2019
Overhead work activities can lead to shoulder pain and serious musculoskeletal disorders (WMSD), such as rotator cuff injury and degeneration. Recently developed exoskeletons show promising results in supporting workers in such activities. In this st...
Background: The main objective of this study was to compare the clinical efficacy of two different devices, the Eptamed elastodontic device and a common bite sold in pharmacies, by assessing a computer aid evaluation of patients’ surface electr...
Wearable electronics is a rapidly growing field that recently started to introduce successful commercial products into the consumer electronics market. Employment of biopotential signals in wearable systems as either biofeedbacks or control commands...
Accurately decoding human locomotion intention from physiological signals remains a significant hurdle for the seamless control of advanced rehabilitation devices like exoskeletons and intelligent prosthetics. Conventional recognition methods often f...
Recently, the application of bio-signals in the fields of health management, human–computer interaction (HCI), and user authentication has increased. This is because of the development of artificial intelligence technology, which can analyze bi...
Rehabilitation is a critical component in the recovery of patients with either complete or partial loss of motor movements. Repeated and slow limb movements are usually advised by practitioners. Advanced robotic systems can help to configure monotono...
The myoelectric activity of the back muscles can be studied to evaluate the flexion-relaxation phenomenon and find differences between electromyography patterns on different subjects. In this paper, we propose an algorithm able to provide a myoelectr...
An accurate monitoring of the professional athletes’ exercises during training sessions is able to improve their performance by helping them in improving the effectiveness of the movement, in the injury prevention and in the rehabilitation protocols....
Obstructive sleep apnea is a respiratory problem that has serious consequences for physical and mental health, but also in monetary terms, since traffic accidents and poor work performance, among other direct consequences, are attributed to it. It is...
Surface electromyography (sEMG) monitoring has recently inspired new applications in the field of patient diagnose, rehabilitation therapy, man–machine–interface and prosthesis control. However, conventional wet electrodes for sEMG record...
29 July 2021
This study investigated the influence of passive back-support exoskeletons (EXOBK) design, trunk sagittal inclination (TSI), and gender on the effectiveness of an exoskeleton to limit erector spinae muscle (ES) activation during a sagittal lifting/lo...
28 July 2023
The aim of this study was to assess, for both men and women, the consequences of using different back-support exoskeletons during various manual material tasks (MMH) on the activity of back muscles and trunk kinematics. Fifteen men and fourteen women...
Cerebral palsy is a disorder of central motor and postural development, resulting in limited mobility. Cerebral palsy is often accompanied by cognitive impairment and abnormal behavior, significantly impacting individuals and society. Time, energy, a...
Hands-free command interfaces are essential for users who cannot reliably operate joysticks or upper-limb myoelectric control. Neck–shoulder surface electromyography (sEMG) is a promising alternative; however, performance is often reported usin...
This study aims to develop a “sensing-actuation integrated” intelligent pressurized thigh band to assist the quadriceps, indirectly alleviate knee joint load, and achieve high-precision recognition of movement modes. The system comprises...
Electromyographic (EMG) signals are increasingly used in wearable cyber–physical systems (CPS), where reliable movement recognition must be achieved under limited computational resources. In this study, we present a compact EMG processing frame...
This study explores the development and validation of a low-cost electromyography (EMG) device for monitoring muscle activity and muscle fatigue by monitoring the key features in EMG time and frequency domains. The device consists of a Raspberry Pico...
Objectives: To investigate eating episodes in a group of adolescents in their home-setting using wearable electromyography (EMG) and camera, and to evaluate the agreement between the two devices. Approach: Fifteen adolescents (15.5 ± 1.3 years...
In this study, we design an embedded surface EMG acquisition device to conveniently collect human surface EMG signals, pursue more intelligent human–computer interactions in exoskeleton robots, and enable exoskeleton robots to synchronize with...
This work describes the development of a leg sleeve with embedded e-textile electrodes for surface electromyography (sEMG). The novel device is a textile substrate with embedded circular electrodes made of conductive fabric, which can be connected to...
Since the triboelectric nanogenerator (TENG) was invented, it has received extensive attention from researchers. Among the many pieces of research based on TENG, the research of hybridized generators is progressing rapidly. In recent years, the resea...
The pulse source for plasma-accelerators supply operates under the conditions of nonlinear growth of load inductance, which complicates the matching of the source and the load. This article presents experimental studies of the use of both traditional...
Objective: percutaneous pedicle screw (PPS) fixation has been widely used in minimally invasive spine stabilization. Triggered electromyogram (TrEMG) monitoring is performed to prevent PPS misplacement, but is not widely accepted. We have newly devel...
Background: The gold standard for diagnosing sleep bruxism (SB) and obstructive sleep apnea (OSA) is polysomnography (PSG). However, a final hypermotor muscle activity often occurs after apnea episodes, which can confuse the diagnosis of SB when usin...
Resistance exercise with devices offering mechanisms to isolate the lumbar spine is effective to improve muscle strength and clinical outcomes. However, previously assessed devices with these mechanisms are not conducive for home exercise programs. T...
Objective: The instrumental measurement of electromyographic (EMG) activity in the natural environment is the best strategy available to collect information on bruxism. The twofold aim of this study was to (1) introduce and discuss a novel EMG device...
Most students and researchers with limited funding are often looking for simple and low-cost devices for the acquisition of the electromyogram signal (EMG) in an educational or research setting. Thus, off-the-shelf devices are used and they have alre...
of 9