Skip to Content

35 Results Found

  • Review
  • Open Access
122 Citations
16,987 Views
37 Pages

Environmental and Health Effects of Ventilation in Subway Stations: A Literature Review

  • Yueming Wen,
  • Jiawei Leng,
  • Xiaobing Shen,
  • Gang Han and ,
  • Lijun Sun and
  • Fei Yu
  • + 1 author+ 0 author

Environmental health in subway stations, a typical type of urban underground space, is becoming increasingly important. Ventilation is the principal measure for optimizing the complex physical environment in a subway station. This paper narratively r...

(This article belongs to the Special Issue Urban Environment and Health)
  • Article
  • Open Access
6 Citations
3,262 Views
16 Pages

Stratum Ventilation: Enabling Simultaneous Energy Conservation and Air Purification in Subway Cars

  • Yanhui Mao,
  • Shengxu Wang,
  • Jianzhou Liang,
  • Saiqin Mao and ,
  • Yukun Han and
  • Shengquan Zhang
  • + 1 author+ 0 author

The supply of fresh air for underground rail transit systems is not as simple as opening windows, which is a conventional ventilation (CV) measure adopted in aboveground vehicles. This study aims to improve contaminant dilution and air purification i...

(This article belongs to the Special Issue Reducing Air Pollution in Smart and Sustainable Future Cities)
  • Article
  • Open Access
3 Citations
1,895 Views
28 Pages

Study on the Impact of Ventilation Methods on Droplet Nuclei Transmission in Subway Carriages

  • Xinkai Wu,
  • Rui Ling,
  • Xingyu Wan,
  • Haihua Ren and ,
  • Xuerun Jing and
  • Guozeng Feng
  • + 1 author+ 0 author

29 April 2025

The environment inside subway carriages is relatively enclosed, putting passengers at risk of respiratory infections during viral pandemics such as COVID-19 and SARS. This paper uses the Euler–Lagrange method to simulate the distribution of dro...

  • Article
  • Open Access
5 Citations
3,497 Views
13 Pages

29 June 2022

The ventilation performance of air shafts is important to the air quality of subway tunnels, but there is no unified evaluation index of ventilation performance. In this paper, the air shafts at different locations in subway tunnels were taken as res...

(This article belongs to the Section Air Quality and Health)
  • Article
  • Open Access
1 Citations
3,593 Views
22 Pages

7 August 2025

Ventilation in subway and railway tunnels is a critical safety component, especially during fire emergencies, where effective smoke and heat management is essential for successful evacuation and firefighting efforts. The Subway Environmental Simulati...

(This article belongs to the Special Issue Modeling, Experiment and Simulation of Tunnel Fire)
  • Article
  • Open Access
2 Citations
3,352 Views
15 Pages

Effects of Tunnel and Its Ventilation Modes on the Aerodynamic Drag of a Subway Train

  • Hanfeng Wang,
  • Honglei Tian,
  • Jian Du,
  • Yu Zhou and ,
  • Md. Mahbub Alam,
  • Jiefeng Huang and
  • Guibo Li
  • + 2 authors+ 0 author

5 December 2022

This paper reports an in situ measurement on the effects of a tunnel and its ventilation modes on the aerodynamic drag of a subway train with eight carriages during its routine operation. The train speed (V) varied continually from 0 to 22 m/s. Two m...

(This article belongs to the Special Issue Advances in Aerodynamics of Railway Train/Tunnel System)
  • Article
  • Open Access
7 Citations
4,082 Views
31 Pages

4 September 2024

In rapidly urbanizing regions, enhancing passenger comfort in subway systems through sustainable methods is a critical challenge. This study introduces an innovative exploration of the impact of subway entrance geometry on natural ventilation and its...

(This article belongs to the Topic Ventilation and Indoor Air Quality, 2nd Edition)
  • Article
  • Open Access
2 Citations
2,383 Views
17 Pages

Study on Performance of Coordinated Ventilation Strategies during T-Shaped Subway Station Hall Fire

  • Yanan Hou,
  • Wei Ding,
  • Zhengbo Hou,
  • Xingcheng Li and ,
  • Ling Li,
  • Zhihao Yang and
  • Congling Shi
  • + 2 authors+ 0 author

29 January 2025

A subway transfer station hall is crowded and complex in structure, which makes evacuation more difficult in case of a fire, but also provides more strategic options for smoke extraction. Full-scale experiments and numerical simulations are conducted...

(This article belongs to the Special Issue Dynamics of Wind-Fire Interaction: Fundamentals and Applications)
  • Article
  • Open Access
355 Views
25 Pages

10 September 2026

The process drawing of ventilation and air conditioning systems in subway stations is an important component of HVAC design deliverables because it describes monitoring requirements, control logic, and operating modes. However, the large number of mo...

(This article belongs to the Section Building Energy, Physics, Environment, and Systems)
  • Feature Paper
  • Article
  • Open Access
33 Citations
5,155 Views
18 Pages

12 April 2019

Smoke control is a crucial issue in a long-distance subway tunnel fire, and a two-point extraction ventilation system is an effective way to solve this problem, due to the characteristics of controlling the smoke in a limited area and removing high-t...

(This article belongs to the Section J: Thermal Management)
  • Article
  • Open Access
18 Citations
5,700 Views
29 Pages

Reducing Virus Transmission from Heating, Ventilation, and Air Conditioning Systems of Urban Subways

  • Ata Nazari,
  • Jiarong Hong,
  • Farzad Taghizadeh-Hesary and
  • Farhad Taghizadeh-Hesary

17 December 2022

Aerosols carrying the virus inside enclosed spaces is an important mode of transmission for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), as supported by growing evidence. Urban subways are one of the most frequented enclosed spaces....

(This article belongs to the Topic Environmental Toxicology and Human Health)
  • Article
  • Open Access
9 Citations
4,748 Views
17 Pages

15 July 2022

During the actual operation of a subway company, only one ventilation-control scheme is considered in the emergency plan, without considering the specific location difference of the fire source. However, in the case of an actual tunnel fire, the best...

  • Article
  • Open Access
4 Citations
3,257 Views
16 Pages

25 September 2022

The city of Seoul will limit the maximum particulate matter (PM10) concentration to ≤35 μg/m3 (from 2024). Herein, a numerical parametric study was conducted on the PM removal efficiency of the heating, ventilation, and air conditioning (HVAC)...

(This article belongs to the Special Issue Source Identification, Monitoring, Health Effect and Control Technologies of Indoor Air Pollutants in Indoor Such as Subway Systems, Multi-Purpose Utilities, School Rooms)
  • Article
  • Open Access
10 Citations
3,611 Views
14 Pages

8 August 2022

Critical velocity is very important for smoke control in longitudinally ventilated subway tunnel fires. Numerical investigations are conducted in this paper to study the impacts of metro train blockages on critical velocity in sloping subway tunnel f...

(This article belongs to the Special Issue Experiments and Simulations of Combustion Process)
  • Article
  • Open Access
5 Citations
2,565 Views
12 Pages

3 November 2023

It is not uncommon that subways count as densely populated areas, so air quality standards, including fine dust concentration, have been established for them. As passengers and subway staff are exposed to potentially harmful airborne particles, addre...

(This article belongs to the Special Issue Advances in Built Environment Engineering: Ventilation, Air Conditioning, and Heating Technology)
  • Article
  • Open Access
912 Views
16 Pages

Impact of Air Filter Cleaning in the Subway Ventilation System on Pollutant Distribution at Different Stations: A Case Study of Xi’an

  • Xin Zhang,
  • Zixu Huang,
  • Bing Luo,
  • Shuangping Duan and ,
  • Yong Jin,
  • Min Zou,
  • Lihua Mi and
  • Rui Tao
  • + 3 authors+ 0 author

11 February 2026

This study aims to address the lack of systematic research on how air filter cleaning affects pollutant distribution in subway stations, an urgent issue for ensuring indoor air quality in enclosed underground transit environments. Taking a representa...

(This article belongs to the Section Building Energy, Physics, Environment, and Systems)
  • Article
  • Open Access
11 Citations
8,554 Views
29 Pages

19 August 2022

Almost all recently built subway stations are equipped with Platform Screen Doors (PSDs) due to the numerous proven benefits of these systems. In addition, PSDs are now being introduced in existing subway stations, but their operation in conjunction...

(This article belongs to the Special Issue Urban Sustainability and Resilience of the Built Environments)
  • Article
  • Open Access
35 Citations
5,294 Views
15 Pages

23 September 2022

Particulate matter (PM) of sizes less than 10 µm (PM10) and 2.5 µm (PM2.5) found in the environment is a major health concern. As PM is more prevalent in an enclosed environment, such as a subway station, this can have a negative impact o...

(This article belongs to the Special Issue Source Identification, Monitoring, Health Effect and Control Technologies of Indoor Air Pollutants in Indoor Such as Subway Systems, Multi-Purpose Utilities, School Rooms)
  • Article
  • Open Access
18 Citations
2,799 Views
20 Pages

10 January 2024

Droplet transmission is a critical pathway for the spread of respiratory infectious viruses. A thorough understanding of the mechanisms of droplet dispersion within subway carriages is crucial to curb the widespread transmission of the virus. This st...

(This article belongs to the Topic COVID-19 Impact on the Environment and Sustainable Development)
  • Article
  • Open Access
7 Citations
5,824 Views
15 Pages

2 December 2016

The need for reduction in power consumption for public facilities has increased after the occurrences of multiple blackout events. In an effort to enable the development of green and smart social infrastructure, this paper introduces a design for a s...

(This article belongs to the Special Issue Symmetry in Systems Design and Analysis)
  • Article
  • Open Access
460 Views
31 Pages

17 July 2026

This study evaluates winter in-car microclimate and aerosol conditions in a Prague Metro line C M1.3 car under real operation. Five Letňany–Háje runs were divided into 19 inter-station segments. TDC, PM10, PM4, PM2.5, PM1, CO2, air...

(This article belongs to the Special Issue Green Transportation and Pollution Control)
  • Article
  • Open Access
18 Citations
3,769 Views
12 Pages

29 March 2022

The special emergency plan for subway fires in China stipulates that when a fire occurs at a train stop, it is necessary to confirm whether the fire mode of the tunnel ventilation system is implemented. Because of the setting mode of tunnel ventilati...

  • Article
  • Open Access
8 Citations
8,088 Views
15 Pages

10 January 2025

Air pollution remains a critical global health concern, with 91% of the world’s population exposed to air quality exceeding World Health Organization (WHO) standards and indoor pollution causing approximately 3.8 million deaths annually due to...

(This article belongs to the Special Issue Remote Sensing of Particulate Matter, Its Components and Air Pollution Assessment)
  • Article
  • Open Access
5 Citations
4,200 Views
26 Pages

15 November 2022

Among public facilities, facilities belonging to Multi-Group (I) include high-rise buildings, tunnels, and subway stations, and the location of Shelter in Place (SIP) is an important factor in the safety of citizens. However, subway evacuation maps u...

(This article belongs to the Section Construction Management, and Computers & Digitization)
  • Article
  • Open Access
11 Citations
3,597 Views
18 Pages

Numerical Simulation on the Smoke Prevention Performance of Air Curtains in an Island-Type Subway Station

  • Xu Yan,
  • Hongyun Yang,
  • Huiqiang Mo,
  • Ye Xie and ,
  • Zhongfu Jin and
  • Yang Zhou
  • + 1 author+ 0 author

26 April 2023

Subway fires are a major threat to the safe and smooth operation of subway stations. In this paper, an island-type subway station was taken as an example to conduct a series of numerical simulations using Fire Dynamics Simulator (FDS). The temperatur...

(This article belongs to the Special Issue Fire Numerical Simulation)
  • Article
  • Open Access
9 Citations
4,437 Views
20 Pages

Reducing PM10 and PM2.5 Concentrations in a Subway Station by Changing the Diffuser Arrangement

  • Seong-Gyu Kim,
  • Gibong Sung,
  • Se-Jin Yook,
  • Minjeong Kim and
  • Duckshin Park

15 September 2022

According to the stringent regulations on particulate matter (PM) concentrations in Seoul, Korea, the PM10 and PM2.5 concentrations in subway stations must be maintained below 50 and 30 μg/m3, respectively, by 2024. Therefore, the PM concentration...

(This article belongs to the Special Issue Source Identification, Monitoring, Health Effect and Control Technologies of Indoor Air Pollutants in Indoor Such as Subway Systems, Multi-Purpose Utilities, School Rooms)
  • Article
  • Open Access
4 Citations
3,258 Views
13 Pages

Effects of Train-Induced Unsteady Airflow on Air Quality and Air Distribution in a Subway Station

  • Hu Li,
  • Hong Han,
  • Xinjin Liu,
  • Shujing Chen and ,
  • Jingqian Wang and
  • Wenjun Lei
  • + 1 author+ 0 author

1 December 2022

Using train-induced unsteady airflow in transitional seasons can greatly reduce the energy consumption of a subway station’s mechanical ventilation. However, the unsteady airflow carries the particles from tunnels into subway platforms, and air...

(This article belongs to the Section Building Energy, Physics, Environment, and Systems)
  • Article
  • Open Access
14 Citations
3,262 Views
27 Pages

27 February 2025

With the accelerated development of subways in China, elevated subway stations (ESSs) capitalize on natural ventilation and lighting to significantly save energy. Nevertheless, their thermal environments are rarely addressed. This study conducts annu...

(This article belongs to the Topic Advances in Low-Carbon, Climate-Resilient, and Sustainable Built Environment)
  • Review
  • Open Access
16 Citations
4,898 Views
24 Pages

Ventilation Strategies for Highly Occupied Public Environments: A Review

  • Yongzhi Zhang,
  • Zengrui Guo,
  • Lanting Zhuo,
  • Nirui An and
  • Yifei Han

In urban public transportation and highly diversified air environments, air pollutant exposure is becoming an increasing concern in terms of public health and personal safety. Herein, the scientific literature on air quality and virus transmission in...

(This article belongs to the Section Building Energy, Physics, Environment, and Systems)
  • Article
  • Open Access
1,026 Views
16 Pages

Particulate Matter Migration in Subway Tunnels: Experimental and Numerical Investigation

  • Haiying Wang,
  • Yifeng Wang,
  • Chudong Hu,
  • Yan Wu and
  • Jianbin Zang

10 March 2026

Platform screen door (PSD) systems can reduce particulate matter (PM) levels at subway platforms, but transient particle migration between tunnels and platforms still occurs during door operation. Existing control measures, such as tunnel cleaning, v...

(This article belongs to the Section Air Quality)
  • Article
  • Open Access
1 Citations
1,618 Views
19 Pages

12 May 2025

This study examines factors affecting the thermal expansion behavior of continuous welded rails (CWRs) in urban rail systems and investigates conditions that lead to rail weld fractures. Parameters affecting CWR fractures near ventilation shafts in u...

(This article belongs to the Section Transportation and Future Mobility)
  • Article
  • Open Access
351 Views
19 Pages

Research on Comprehensive Evaluation of Air Quality in Underground Stations of Urban Rail Transit Systems

  • Jinyan Liu,
  • Minghui Liu,
  • Qianyu Tang,
  • Zhuoran Chen and ,
  • Wanhua Li,
  • Chen Zhang,
  • Yunling Zhang and
  • Lihua Yin
  • + 3 authors+ 0 author

26 September 2026

Research purposes: This paper proposes an entropy-weighted-linear weighting integrated evaluation approach combining numerical simulation with field measurements. Using a specific island-type station in Beijing Metro as a case study, the research fir...

(This article belongs to the Special Issue Indoor Air Pollution: A Silent Threat to Human Health and the Atmosphere (2nd Edition))
  • Article
  • Open Access
8 Citations
3,626 Views
21 Pages

Exposure to PM2.5 on Public Transport: Guidance for Field Measurements with Low-Cost Sensors

  • Kyriaki-Maria Fameli,
  • Konstantinos Moustris,
  • Georgios Spyropoulos and
  • Dimitrios-Michael Rodanas

7 March 2024

Air pollution is one of the most important problems in big cities, resulting in adverse health effects. The aim of the present study was to characterize the personal exposure to indoor and outdoor pollution in the Greater Athens Area in Greece by tak...

(This article belongs to the Special Issue Composition Analysis and Health Effects of Atmospheric Particulate Matter)
  • Review
  • Open Access
2 Citations
2,120 Views
19 Pages

Assessing Human Exposure to Fire Smoke in Underground Spaces: Challenges and Prospects for Protective Technologies

  • Jialin Wu,
  • Meijie Liu,
  • Yongqi Tang,
  • Yehui Xu and ,
  • Feifan He,
  • Jinghong Wang,
  • Yunting Tsai,
  • Yi Yang and
  • Zeng Long
  • + 4 authors+ 0 author

7 November 2025

Urban underground spaces, including tunnels, subways, and underground commercial buildings, have grown quickly as urbanization has progressed. Fires frequently break out following industrial accidents and multi-hazard natural disasters, and they can...

(This article belongs to the Special Issue Sustainable Management of Multi-Hazard Natural Disasters and Industrial Accidents)
  • Article
  • Open Access
520 Views
22 Pages

13 July 2026

With the acceleration of urbanization, wind environment problems in high-density blocks have become increasingly prominent. Most existing studies only focus on the identification of influencing factors, lacking a complete closed loop from “diag...

(This article belongs to the Special Issue Low-Altitude Boundary-Layer Flows and Dispersion: Insights from Experiments, Modeling and AI)