14 pages, 4205 KB  
Article
A Comparative Analysis of Lead-Free Piezoelectric Micromachined Ultrasonic Transducers for Powered Bio-Sensing
by Alexandru Paolo Mardare, Mamoun Morh and Aldo Ghisi
Micromachines 2026, 17(7), 845; https://doi.org/10.3390/mi17070845 - 16 Jul 2026
Viewed by 179
Abstract
To exploit ultra-low power logic and architectural design techniques for bio-sensors in the human body, wireless ultrasonic techniques have emerged as a strong candidate for intra-body power transmission, thanks to lower medium attenuation and higher permitted safe intensity levels. When sub-100 μm [...] Read more.
To exploit ultra-low power logic and architectural design techniques for bio-sensors in the human body, wireless ultrasonic techniques have emerged as a strong candidate for intra-body power transmission, thanks to lower medium attenuation and higher permitted safe intensity levels. When sub-100 μm dimensions are considered for the bio-sensor, most devices struggle to guarantee a suitable voltage and power for digital electronics due to additional scaling requirements. This study investigates three alternative piezoelectric micromachined ultrasonic transducers in aluminum nitride doped with scandium, as reported in the literature, operating in the range 1–10 MHz. Their respective advantages and limitations with regard to energy harvesting and signal transmission performance are analyzed. It is shown that devices with footprints of less than 100 × 100 μm2 can achieve voltage outputs of over 150 mV and average power greater than 100 nW. Full article
(This article belongs to the Special Issue Piezoelectric Microdevices for Energy Harvesting)
Show Figures

Figure 1

18 pages, 4537 KB  
Article
Electromechanical and Acoustic Characterization of Dual-Mode Rectangular PMUT
by Yumna Birjis and Arezoo Emadi
Microelectronics 2026, 2(2), 6; https://doi.org/10.3390/microelectronics2020006 - 9 Apr 2026
Viewed by 1585
Abstract
Multifrequency operation in micromachined ultrasonic transducers, enabled by targeted excitation of specific vibrational modes, has emerged as an attractive approach for achieving tunable performance and configurability, well-suited for advanced ultrasound imaging and therapeutic applications. This paper presents a dual-electrode rectangular piezoelectric micromachined ultrasonic [...] Read more.
Multifrequency operation in micromachined ultrasonic transducers, enabled by targeted excitation of specific vibrational modes, has emerged as an attractive approach for achieving tunable performance and configurability, well-suited for advanced ultrasound imaging and therapeutic applications. This paper presents a dual-electrode rectangular piezoelectric micromachined ultrasonic transducer (PMUT) designed for efficient dual-frequency operation through mode-selective actuation. The proposed architecture employs segmented electrodes that are spatially aligned with the strain distributions of two distinct flexural modes, enabling selective excitation of Mode 1 (fundamental) and Mode 3 (higher order) through appropriate electrode actuation. Finite element simulations and impedance analysis were used to guide the electrode configuration and validate the mode-selective behavior. The dual-mode PMUT was fabricated alongside a conventional single-electrode PMUT using identical membrane dimensions and material stack for direct comparison. Comprehensive electrical and underwater acoustic characterization confirmed that the conventional PMUT is limited to single-frequency operation at the fundamental resonance. In contrast, the proposed design achieved a substantial improvement in higher-order performance, with a threefold increase in acoustic pressure at Mode 3 compared to the conventional device. These results demonstrate that mode-aligned electrode segmentation enables efficient dual-mode operation without added fabrication complexity, making the design highly suitable for multifrequency ultrasonic applications such as biomedical imaging and sensing. Full article
Show Figures

Figure 1

12 pages, 5931 KB  
Article
PiezoMEMS Fabrication on Flexible Stainless-Steel Substrates
by Kae Nakamura, Chi-Luen Huang, Ali Habib Akhyari, Andrea P. Argüelles, Thomas N. Jackson and Susan Trolier-McKinstry
Sensors 2026, 26(7), 2246; https://doi.org/10.3390/s26072246 - 5 Apr 2026
Cited by 1 | Viewed by 1811
Abstract
A bottom-up fabrication approach for flexible piezoelectric micromachined ultrasound transducer (PMUT) arrays on stainless-steel substrates was developed. Devices were fabricated using chemical solution deposition of a 700 nm-thick layer of Pb0.990.01(Zr0.52Ti0.48)Nb0.02O3, [...] Read more.
A bottom-up fabrication approach for flexible piezoelectric micromachined ultrasound transducer (PMUT) arrays on stainless-steel substrates was developed. Devices were fabricated using chemical solution deposition of a 700 nm-thick layer of Pb0.990.01(Zr0.52Ti0.48)Nb0.02O3, where □ denotes a vacancy on the Pb site, on 50 μm-thick LaNiO3/HfO2/stainless-steel foils. Lithography for definition of the electrode and piezoelectric layers was completed on the front of the wafer. Ni electroplating on the back side of the foil was used to create locally stiff areas to define the deflection area. PMUT devices were successfully fabricated using this method. The permittivity and loss tangent of the fabricated device at 1 kHz were 283 ± 9 and <1.5%, respectively. The remanent polarization was measured to be 38 ± 0.3 μC/cm2. Full article
Show Figures

Figure 1

19 pages, 5205 KB  
Article
High-Frequency Ultrasound Focusing Using Low-Cost PMMA and PDMS Acoustic Lenses
by Mohammadamir Ghasemishabankareh, Zeyuan Hui, Francesc Torres and Núria Barniol
Micromachines 2026, 17(4), 414; https://doi.org/10.3390/mi17040414 - 28 Mar 2026
Viewed by 2013
Abstract
This study presents a high-frequency ultrasound lens system that uses simply fabricated and low-cost acoustic lenses made from PMMA and PDMS materials. These lenses are designed for higher-frequency operation around 20 MHz, providing suitability for demanding high-frequency ultrasonic applications. They were designed and [...] Read more.
This study presents a high-frequency ultrasound lens system that uses simply fabricated and low-cost acoustic lenses made from PMMA and PDMS materials. These lenses are designed for higher-frequency operation around 20 MHz, providing suitability for demanding high-frequency ultrasonic applications. They were designed and fabricated specifically for integration with a PMUT array, ensuring proper compatibility with array-based high-frequency ultrasonic imaging. Both Fresnel and convex lens designs were evaluated through axial and lateral beam measurements, along with pulse–echo testing in the focal region. The results show that the PMMA and PDMS lenses can produce a well-defined focus and a stable echo response despite their simple and low-cost fabrication. This demonstrates the feasibility of low-cost materials for high-frequency ultrasonic focusing in PMUT array applications. Full article
(This article belongs to the Special Issue MEMS Ultrasonic Transducers, 2nd Edition)
Show Figures

Figure 1

18 pages, 6963 KB  
Article
First-Principles Calculations and PMUT Applications of Piezoelectric Thin-Film Materials
by Chengwei Che, Shanqing Yi, Caishuo Zhang, Xinyi Zheng, Xingli He and Dacheng Xu
Micromachines 2026, 17(3), 377; https://doi.org/10.3390/mi17030377 - 20 Mar 2026
Viewed by 635
Abstract
High-performance piezoelectric micromachined ultrasonic transducers (PMUTs) are crucial for portable medical imaging and sensing. The efficiency of advanced PMUTs relies on high-quality piezoelectric thin films and optimized device designs. However, variability in common piezoelectric thin films like ScxAl1−xN (ScAlN) [...] Read more.
High-performance piezoelectric micromachined ultrasonic transducers (PMUTs) are crucial for portable medical imaging and sensing. The efficiency of advanced PMUTs relies on high-quality piezoelectric thin films and optimized device designs. However, variability in common piezoelectric thin films like ScxAl1−xN (ScAlN) and PbZr1−xTixO3 (PZT) often leads to inaccurate material parameters—especially those derived from thick ceramics. To enhance simulation accuracy in standard designs affected by these inconsistencies, this work introduces an optimization framework combining first-principles calculations with multiphysics simulations. First, the intrinsic properties of PZT and ScAlN are analyzed through atomistic calculations, confirming that PZT, with its higher electromechanical coupling coefficient, is better suited for actuation. The parameters obtained from these calculations calibrate the finite-element model, addressing issues of missing or inaccurate data in commercial software libraries. Next, an efficient analytical acoustic-field model is developed. Compared to full-wave simulations in COMSOL, this model significantly reduces computational cost while maintaining accuracy, allowing for quicker scanning and optimization of large-array topologies. Additionally, results demonstrate that each individual hexagonal PMUT element outperforms a comparable circular element, achieving a peak SPL of 90.4 dB at 4.9 MHz versus 89.7 dB at 2.8 MHz. This higher acoustic output and operating frequency enable improved spatial resolution and sensitivity. This modeling approach, based on intrinsic material properties, provides a solid theoretical foundation for designing high-precision, low-power ultrasonic devices. Full article
Show Figures

Figure 1

20 pages, 9096 KB  
Article
Beam Drift Mitigation and Wide-Range Measurement in a Miniaturized Ultrasonic Gas Flowmeter
by Shanfeng Hou, Xueying Xiu, Chengguang Liu, Haochen Lyu and Songsong Zhang
Micromachines 2026, 17(2), 254; https://doi.org/10.3390/mi17020254 - 16 Feb 2026
Viewed by 1630
Abstract
To mitigate acoustic beam drift, which degrades the signal-to-noise ratio (SNR) and limits the measurement range in ultrasonic gas flowmeters (USFMs), we present a miniaturized transit-time USFM that integrates a single piezoelectric micromachined ultrasonic transducer (PMUT) with a non-axisymmetric conical cavity. This design [...] Read more.
To mitigate acoustic beam drift, which degrades the signal-to-noise ratio (SNR) and limits the measurement range in ultrasonic gas flowmeters (USFMs), we present a miniaturized transit-time USFM that integrates a single piezoelectric micromachined ultrasonic transducer (PMUT) with a non-axisymmetric conical cavity. This design increases acoustic transmission gain and produces anisotropic directivity across orthogonal radiation planes, thereby broadening acoustic coverage along the flow direction and reducing beam steering. With an optimized cavity angle combination of (50°, 70°), the system achieves a 7.4 dB transmission gain and a half-power beamwidth (HPBW) of 29.1°. Experimental validation demonstrates a sound pressure attenuation of only 0.72 dB at 18.74 m/s. Within the 0.06–12 m3/h flow range, the USFM exhibits indication errors of ±2% (<1 m3/h) and ±1.5% (≥1 m3/h), with repeatability below 0.5%. The performance meets the Class 1.5 accuracy standard specified in CJ/T 477-2015, offering an innovative solution for wide-range miniaturized gas flow measurement. Full article
(This article belongs to the Special Issue Acoustic Transducers and Their Applications, 3rd Edition)
Show Figures

Figure 1

10 pages, 2807 KB  
Article
Dual-Electrodes PMUTs on Glasses for Wearable Human Blink Monitoring
by Xiao-Xin Liang, Haochen Wu and Yong Wang
Micromachines 2026, 17(1), 90; https://doi.org/10.3390/mi17010090 - 9 Jan 2026
Cited by 1 | Viewed by 2087
Abstract
Blink monitoring has demonstrated significant application value in fields such as safety assessments, medical monitoring, and intelligent technologies. Traditional eye monitoring methods are limited by restricted adaptability, insufficient comfort, or potential risks. MEMS-based ultrasonic technology, as a non-contact approach, has garnered attention due [...] Read more.
Blink monitoring has demonstrated significant application value in fields such as safety assessments, medical monitoring, and intelligent technologies. Traditional eye monitoring methods are limited by restricted adaptability, insufficient comfort, or potential risks. MEMS-based ultrasonic technology, as a non-contact approach, has garnered attention due to its strong environmental adaptability, privacy, and security. However, existing designs require high-sensitivity processing circuits and are incompatible with standard fabrication processes. This work proposes a dual-electrode piezoelectric micro-mechanical ultrasonic transducer (PMUT) design based on aluminum nitride (AlN) piezoelectric thin films, integrated into a glasses device to enable real-time blink activity monitoring. The design successfully identifies blink states through time-of-flight (TOF) pulse-echo technology and dynamic unsupervised learning methods. Fabricated using cost-effective standard multi-user MEMS processes, this device offers distinct merits in terms of wearability comfort, information security, biosafety, and reliability. Full article
(This article belongs to the Section A:Physics)
Show Figures

Figure 1

29 pages, 1670 KB  
Review
Advances in Crosstalk Reduction Techniques for Ultrasonic Transducer Arrays
by Anouar Boujenoui, Nadia El Atlas, Abdelmajid Bybi, Hayat Reskal and Lahoucine Elmaimouni
Sensors 2025, 25(24), 7666; https://doi.org/10.3390/s25247666 - 18 Dec 2025
Cited by 3 | Viewed by 2978
Abstract
Crosstalk between elements in ultrasonic transducer arrays significantly degrades image quality in medical ultrasound systems by introducing noise and reducing spatial resolution. This review provides a comprehensive overview of the origins of crosstalk—acoustic, mechanical, and electrical—and the main characterization methods used to analyze [...] Read more.
Crosstalk between elements in ultrasonic transducer arrays significantly degrades image quality in medical ultrasound systems by introducing noise and reducing spatial resolution. This review provides a comprehensive overview of the origins of crosstalk—acoustic, mechanical, and electrical—and the main characterization methods used to analyze it, including direct measurements, impedance analysis, finite element modeling, and equivalent circuit approaches. Emphasis is placed on recent advances in passive and active mitigation strategies, such as material coatings, structural decoupling, phononic crystals, adaptive filtering, and impedance matching. A key finding is that the optimal crosstalk reduction method depends strongly on the transducer technology employed—whether CMUT, PMUT, or bulk PZT. The review highlights the importance of tailoring mitigation techniques to the physical properties and operating conditions of each technology. By synthesizing current knowledge and identifying remaining challenges—particularly the role of filler material losses—this work offers a solid foundation for the development of next-generation ultrasound arrays with enhanced imaging performance. Full article
(This article belongs to the Section Intelligent Sensors)
Show Figures

Figure 1

17 pages, 4660 KB  
Article
Structural Optimization and Simulation of Dual-Frequency Piezoelectric Micromachined Ultrasonic Transducers
by Fengwen Wang, Longlong Cao and Mingliang Jin
Micromachines 2025, 16(11), 1296; https://doi.org/10.3390/mi16111296 - 19 Nov 2025
Cited by 1 | Viewed by 3118
Abstract
Ultrasound transducers are fundamental components in medical imaging systems, impacting resolution, sensitivity, and penetration depth. A key challenge in designing high-performance ultrasound transducers is balancing bandwidth and sensitivity. This study focuses on optimizing the backing layer of a dual-frequency piezoelectric micromachined ultrasound transducer [...] Read more.
Ultrasound transducers are fundamental components in medical imaging systems, impacting resolution, sensitivity, and penetration depth. A key challenge in designing high-performance ultrasound transducers is balancing bandwidth and sensitivity. This study focuses on optimizing the backing layer of a dual-frequency piezoelectric micromachined ultrasound transducer (PMUT) using polydimethylsiloxane (PDMS). COMSOL multi-physics version 6.2 finite element simulations and equivalent circuit modeling were employed to investigate the effects of PDMS backing layer thickness and geometry on frequency response characteristics, impedance matching, and acoustic sensitivity. The optimized PMUT structure demonstrated a significant enhancement in bandwidth, with the −6 dB bandwidth increasing to 92% at both 2.3 MHz and 6.8 MHz frequencies. The PDMS backing layer improved the matching of low- and high-frequency signals, enabling high sensitivity and reduced interface reflection losses. The incorporation of PDMS as the backing layer successfully expands the operational bandwidth of dual-frequency PMUTs while maintaining high sensitivity, offering promising potential for high-performance ultrasound imaging, particularly in medical applications requiring both deep penetration and high-resolution imaging. Full article
(This article belongs to the Section A:Physics)
Show Figures

Figure 1

15 pages, 4653 KB  
Article
Design, Fabrication, and Characterization of a Piezoelectric Micromachined Ultrasonic Transducer with a Suspended Cantilever Beam-like Structure with Enhanced SPL for Air Detection Applications
by Yanyuan Ba, Yiming Li and Yuanhang Zhou
Micromachines 2025, 16(11), 1280; https://doi.org/10.3390/mi16111280 - 13 Nov 2025
Cited by 4 | Viewed by 3331
Abstract
Air-coupled ultrasonic detection demands high transmission performance from piezoelectric micromachined ultrasonic transducers (PMUTs). However, existing microelectromechanical system (MEMS)-based PMUTs deliver limited output, which compromises measurement accuracy and constrains further development. This work proposes a novel PMUT design with a cantilevered, boundary-suspended diaphragm that [...] Read more.
Air-coupled ultrasonic detection demands high transmission performance from piezoelectric micromachined ultrasonic transducers (PMUTs). However, existing microelectromechanical system (MEMS)-based PMUTs deliver limited output, which compromises measurement accuracy and constrains further development. This work proposes a novel PMUT design with a cantilevered, boundary-suspended diaphragm that relieves residual stress, relaxes edge constraints, increases the mechanical degrees of freedom, and enables larger vibration amplitudes. Additionally, this work develops an accurate air-coupling model to predict device performance and a streamlined micro-nanofabrication process for device realization. Experimental results show that under a 1 Vpp (−5 Voffset) drive, the device achieves a peak acoustic pressure of 4.004 Pa at 69.3 kHz, measured at 10 cm distance in air, corresponding to a maximum sound pressure level of 106.02 dB (re 2 × 10−5 Pa). Compared to a traditional PMUT at 98.45 dB, this represents a 7.57 dB improvement and, to our knowledge, the highest reported sound pressure level at 10 cm for a single PMUT operating near 70 kHz under a 1 Vpp excitation. These results validate the significant enhancement in transmission performance achieved by the proposed topological structure, offering a solution to overcome the common bottleneck of insufficient output in PMUTs, and indicate strong potential for broader air-coupled sensing applications. Full article
Show Figures

Figure 1

12 pages, 1366 KB  
Proceeding Paper
Energy Harvesting for a Microscale Biosensing Device via Piezoelectric Micromachined Ultrasonic Transducers
by Alexandru Paolo Mardare, Mamoun Morh and Aldo Ghisi
Eng. Proc. 2025, 118(1), 74; https://doi.org/10.3390/ECSA-12-26489 - 7 Nov 2025
Cited by 1 | Viewed by 547
Abstract
Microdevices with dimensions comparable to a blood cell, i.e., tens of micrometers, show great potential for use in the human body. They can be adopted to identify the source of diseases, track their evolution and enhance the effectiveness of therapies, significantly improving patients’ [...] Read more.
Microdevices with dimensions comparable to a blood cell, i.e., tens of micrometers, show great potential for use in the human body. They can be adopted to identify the source of diseases, track their evolution and enhance the effectiveness of therapies, significantly improving patients’ quality of life. A key challenge is how to power the devices, which should ideally be performed wirelessly from a remote source. Piezoelectric micromachined ultrasonic transducers (pMUTs) offer a solution thanks to their ability to generate and collect energy via acoustic waves. In this work, numerical simulations of transmitter pMUT arrays are performed with the aim of generating an acoustic wave synchronized with a single pMUT or pMUT array receiver. The latter is intended for insertion in the human body. The characteristics required to switch on and power nano-electronics, in terms of generated voltage and electrical power at the receiver, are studied in ballistic gel, a material that mimics human organs. The focus is on a bio-compatible material for the piezoelectric layer, i.e., aluminum nitride enriched with scandium. Coupled electromechanical and acoustic simulations show that, of the considered pMUT devices, an 8 × 8 transmitter array combined with a single-device receiver (with a 50 µm pitch) or a 2 × 2 receiver array provide alternative options, with each offering advantages in terms of voltage amplitude or power at a steady state. The overall dimensions of the receiver, at a maximum of only 100 × 100 µm2, is compatible with a future proof-of-concept biosensing platform test chip. Full article
Show Figures

Figure 1

23 pages, 3835 KB  
Article
Computational Saturation Mutagenesis Reveals Pathogenic and Structural Impacts of Missense Mutations in Adducin Proteins
by Lennon Meléndez-Aranda, Jazmin Moreno Pereyda and Marina M. J. Romero-Prado
Genes 2025, 16(8), 916; https://doi.org/10.3390/genes16080916 - 30 Jul 2025
Viewed by 2258
Abstract
Background and objectives: Adducins are cytoskeletal proteins essential for membrane stability, actin–spectrin network organization, and cell signaling. Mutations in the genes ADD1, ADD2, and ADD3 have been linked to hypertension, neurodevelopmental disorders, and cancer. However, no comprehensive in silico saturation [...] Read more.
Background and objectives: Adducins are cytoskeletal proteins essential for membrane stability, actin–spectrin network organization, and cell signaling. Mutations in the genes ADD1, ADD2, and ADD3 have been linked to hypertension, neurodevelopmental disorders, and cancer. However, no comprehensive in silico saturation mutagenesis study has systematically evaluated the pathogenic potential and structural consequences of all possible missense mutations in adducins. This study aimed to identify high-risk variants and their potential impact on protein stability and function. Methods: We performed computational saturation mutagenesis for all possible single amino acid substitutions across the adducin proteins family. Pathogenicity predictions were conducted using four independent tools: AlphaMissense, Rhapsody, PolyPhen-2, and PMut. Predictions were validated against UniProt-annotated pathogenic variants. Predictive performance was assessed using Cohen’s Kappa, sensitivity, and precision. Mutations with a prediction probability ≥ 0.8 were further analyzed for structural stability using mCSM, DynaMut2, MutPred2, and Missense3D, with particular focus on functionally relevant domains such as phosphorylation and calmodulin-binding sites. Results: PMut identified the highest number of pathogenic mutations, while PolyPhen-2 yielded more conservative predictions. Several high-risk mutations clustered in known regulatory and binding regions. Substitutions involving glycine were consistently among the most destabilizing due to increased backbone flexibility. Validated variants showed strong agreement across multiple tools, supporting the robustness of the analysis. Conclusions: This study highlights the utility of multi-tool bioinformatic strategies for comprehensive mutation profiling. The results provide a prioritized list of high-impact adducin variants for future experimental validation and offer insights into potential therapeutic targets for disorders involving ADD1, ADD2, and ADD3 mutations. Full article
(This article belongs to the Section Bioinformatics)
Show Figures

Graphical abstract

13 pages, 7320 KB  
Article
Determination of Main Bearing Dynamic Clearance in a Shield Tunneling Machine Through a Broadband PMUT Array with a Decreased Blind Area and High Accuracy
by Guoxi Luo, Haoyu Zhang, Delai Liu, Wenyan Li, Min Li, Zhikang Li, Lin Sun, Ping Yang, Ryutaro Maeda and Libo Zhao
Sensors 2025, 25(13), 4182; https://doi.org/10.3390/s25134182 - 4 Jul 2025
Cited by 1 | Viewed by 1208
Abstract
Traditional PMUT ultrasonic ranging systems usually possess a large measurement blind area under the integrated transmit–receive mode, dramatically limiting its distance measurement in confined spaces, such as when determining the clearance of large bearing components. Here, a broadband PMUT rangefinder was designed by [...] Read more.
Traditional PMUT ultrasonic ranging systems usually possess a large measurement blind area under the integrated transmit–receive mode, dramatically limiting its distance measurement in confined spaces, such as when determining the clearance of large bearing components. Here, a broadband PMUT rangefinder was designed by integrating six types of different cells with adjacent resonant frequencies into an array. Through overlapping and coupling of the bandwidths from the different cells, the proposed PMUTs showed a wide –6 dB fractional bandwidth of 108% in silicon oil. Due to the broadening of bandwidth, the device could obtain the maximum steady state with less excitation (5 cycles versus 14 cycles) and reduce its residual ring-down (ca. 6 μs versus 15 μs) compared with the traditional PMUT array with the same cells, resulting in a small blind area. The pulse–echo ranging experiments demonstrated that the blind area was effectively reduced to 4.4 mm in air or 12.8 mm in silicon oil, and the error was controlled within ±0.3 mm for distance measurements up to 250 mm. In addition, a specific ultrasound signal processing circuit with functions of transmitting, receiving, and processing ultrasonic waves was developed. Combining the processing circuit and PMUT device, the system was applied to determine the axial clearance of the main bearing in a tunneling machine. This work develops broadband PMUTs with a small blind area and high resolution for distance measurement in narrow and confined spaces, opening up a new path for ultrasonic ranging technology. Full article
(This article belongs to the Section Industrial Sensors)
Show Figures

Figure 1

24 pages, 7263 KB  
Article
Biocompatible and Hermetic Encapsulation of PMUTs: Effects of Parylene F-VT4 and ALD Stacks on Membrane Vibration and Acoustic Performance
by Esmaeil Afshari, Samer Houri, Rik Verplancke, Veronique Rochus, Maarten Cauwe, Pieter Gijsenbergh and Maaike Op de Beeck
Sensors 2025, 25(13), 4074; https://doi.org/10.3390/s25134074 - 30 Jun 2025
Cited by 3 | Viewed by 4244
Abstract
The motivation of this work is to enable the use of piezoelectric micromachined ultrasonic transducer (PMUT)-based implants within the human body for biomedical applications, particularly for power and data transfer for implanted medical devices. To protect surrounding tissue and ensure PMUT functionality over [...] Read more.
The motivation of this work is to enable the use of piezoelectric micromachined ultrasonic transducer (PMUT)-based implants within the human body for biomedical applications, particularly for power and data transfer for implanted medical devices. To protect surrounding tissue and ensure PMUT functionality over time, biocompatible and hermetic encapsulation is essential. This study investigates the impact of Parylene F-VT4 layers of various thicknesses as well as the effect of multilayer stacks of Parylene F-VT4 combined with atomic layer-deposited nanolayers of Al2O3 and HfO2 on the mechanical and acoustic properties of PMUTs. PMUTs with various diameters (40 µm, 60 µm, and 80 µm) are fabricated and tested both as stand-alone devices and as arrays. The mechanical behavior of single stand-alone PMUT devices is characterized in air and in water using laser Doppler vibrometry (LDV), while the acoustic output of arrays is evaluated by pressure measurements in water. Experimental results reveal a non-monotonic change in resonance frequency as a function of increasing encapsulation thickness due to the competing effects of added mass and increased stiffness. The performance of PMUT arrays is clearly influenced by the encapsulation. For certain array designs, the encapsulation significantly improved the arrays’ pressure output, a change that is attributed to the change in the acoustic wavelength and inter-element coupling. These findings highlight the impact of encapsulation in modifying and potentially enhancing PMUT performance. Full article
(This article belongs to the Section Physical Sensors)
Show Figures

Figure 1

19 pages, 3708 KB  
Article
Multiple Ring Electrode-Based PMUT with Tunable Deflections
by Jan Helmerich, Manfred Wich, Annika Hofmann, Thomas Schaechtle and Stefan Johann Rupitsch
Micromachines 2025, 16(6), 623; https://doi.org/10.3390/mi16060623 - 25 May 2025
Cited by 7 | Viewed by 4127
Abstract
Ultrasonic applications such as non-destructive testing, biomedical imaging or range measurements are currently based on piezoelectric bulk transducers. Yet, these kinds of transducers with their mm to cm dimensions are rather impractical in fields in which both frequencies in the kHz region and [...] Read more.
Ultrasonic applications such as non-destructive testing, biomedical imaging or range measurements are currently based on piezoelectric bulk transducers. Yet, these kinds of transducers with their mm to cm dimensions are rather impractical in fields in which both frequencies in the kHz region and small-feature sizes are required. This fact mainly relates to the inverse relationship between the resonance frequency constant and the transducers’ dimension, yielding a higher frequency and attenuation with a decreasing size. Piezoelectric micromachined ultrasonic transducers (PMUTs), in comparison, incorporate a small-scale µm design while preserving the operating frequency in the desired kHz range. This contribution presents the detailed manufacturing of such a PMUT with a multiple ring electrode‑based structure to additionally adjust the sound pressure fields. The PMUT will be characterized by its deflection in air along with the characterization of the piezoelectric material lead zirconate titanate (PZT) itself. The measurements showed a maximum polarization of 21.8 µC/cm2 at 50 kV/cm, the PMUT’s displacement of 30.50 nm/V in air when all electrodes are driven, and an adjustable deflection via different electrode excitations without the need for additional hardware. The ring design also offered the possibility to emit two distinct frequencies simultaneously. These results demonstrate the potential of the designs for small-feature-size applications as they are in high demand for implantable devices, miniaturized ultrasonic-based communication or drug delivery. Full article
(This article belongs to the Special Issue MEMS Ultrasonic Transducers)