Skip to Content
You are currently on the new version of our website. Access the old version .

888 Results Found

  • Review
  • Open Access
290 Citations
37,098 Views
37 Pages

Microfabricated Reference Electrodes and their Biosensing Applications

  • M. Waleed Shinwari,
  • David Zhitomirsky,
  • Imran A. Deen,
  • P. R. Selvaganapathy,
  • M. Jamal Deen and
  • D. Landheer

2 March 2010

Over the past two decades, there has been an increasing trend towards miniaturization of both biological and chemical sensors and their integration with miniaturized sample pre-processing and analysis systems. These miniaturized lab-on-chip devices h...

  • Article
  • Open Access
8 Citations
3,173 Views
11 Pages

Long-Time Evaluation of Solid-State Composite Reference Electrodes

  • Slim Blidi,
  • Kim Granholm,
  • Tomasz Sokalski,
  • Zekra Mousavi,
  • Andrzej Lewenstam,
  • Ivo Leito and
  • Johan Bobacka

In this study, the performance and long-time evaluation of solid-state composite (SSC) reference electrodes were investigated. The stability of all the SSC reference electrodes was continuously monitored by using potentiometry and electrochemical imp...

  • Article
  • Open Access
30 Citations
9,064 Views
22 Pages

Reference Electrodes with Polymer-Based Membranes—Comprehensive Performance Characteristics

  • Peter Lingenfelter,
  • Bartosz Bartoszewicz,
  • Jan Migdalski,
  • Tomasz Sokalski,
  • Mirosław M. Bućko,
  • Robert Filipek and
  • Andrzej Lewenstam

29 November 2019

Several types of liquid membrane and solid-state reference electrodes based on different plastics were fabricated. In the membranes studied, equitransferent organic (QB) and inorganic salts (KCl) are dispersed in polyvinyl chloride (PVC), polyurethan...

  • Article
  • Open Access
16 Citations
10,259 Views
10 Pages

11 September 2003

Different types of Ag/AgCl reference electrodes have been realised by means of thin- and thick-film technique. For inner electrolyte, KCl-containing membranes have been deposited and different coatings have been used to protect the reference electrod...

  • Review
  • Open Access
134 Citations
39,359 Views
24 Pages

18 January 2019

Use of a reference electrode (RE) in Li-ion batteries (LIBs) aims to enable quantitative evaluation of various electrochemical aspects of operation such as: (i) the distinct contribution of each cell component to the overall battery performance, (ii)...

  • Article
  • Open Access
7 Citations
2,392 Views
12 Pages

Response Mechanism of Polymeric Liquid Junction-Free Reference Electrodes Based on Organic Electrolytes

  • Andrey V. Kalinichev,
  • Nadezhda V. Pokhvishcheva and
  • Maria A. Peshkova

16 January 2023

To achieve a transition from conventional liquid-junction reference electrodes (LJF REs) to their all-solid-state alternatives, organic electrolytes are often introduced into the polymeric electrode membranes. In this article, we implement a theoreti...

  • Article
  • Open Access
7 Citations
4,665 Views
15 Pages

Multielectrode Arrays at Wafer-Level for Miniaturized Sensors Applications: Electrochemical Growth of Ag/AgCl Reference Electrodes

  • Haosheng Wu,
  • Robert Krause,
  • Eshanee Gogoi,
  • André Reck,
  • Alexander Graf,
  • Marcus Wislicenus,
  • Olaf R. Hild and
  • Conrad Guhl

4 July 2023

In this study, a range of miniaturized Ag/AgCl reference electrodes with various layouts were successfully fabricated on wafer-level silicon-based substrates with metallic intermediate layers by precisely controlling the electrochemical deposition of...

  • Article
  • Open Access
5 Citations
1 Views
4 Pages

Auditory brainstem response (ABR) peak measures were compared for a custom ear canal electrode and traditional mastoid and ear lobe reference electrode sites with the assumption that the ear canal electrode would yield larger Wave I amplitudes. In th...

  • Article
  • Open Access
44 Citations
13,455 Views
12 Pages

Surface and Electrical Characterization of Ag/AgCl Pseudo-Reference Electrodes Manufactured with Commercially Available PCB Technologies

  • Despina Moschou,
  • Tatiana Trantidou,
  • Anna Regoutz,
  • Daniela Carta,
  • Hywel Morgan and
  • Themistoklis Prodromakis

24 July 2015

Lab-on-Chip is a technology that could potentially revolutionize medical Point-of-Care diagnostics. Considerable research effort is focused towards innovating production technologies that will make commercial upscaling financially viable. Printed ci...

  • Article
  • Open Access
4 Citations
3,594 Views
10 Pages

Development of a Disposable Polyacrylamide Hydrogel-Based Semipermeable Membrane for Micro Ag/AgCl Reference Electrode

  • Eivydas Andriukonis,
  • Marius Butkevicius,
  • Povilas Simonis and
  • Arunas Ramanavicius

24 February 2023

Currently, Ag/AgCl-based reference electrodes are used in most electrochemical biosensors and other bioelectrochemical devices. However, standard reference electrodes are rather large and do not always fit within electrochemical cells designed for th...

  • Proceeding Paper
  • Open Access
5 Citations
3,782 Views
4 Pages

Solid-Contact Reference Electrode for Ion-Selective Sensors

  • Van Anh T. Dam,
  • Martijn Goedbloed and
  • Marcel A. G. Zevenbergen

This work presents a flexible miniaturized ion-selective sensor consisting of a solid-contact reference electrode (RE) and ion-selective electrodes (ISE) fabricated on the same foil. The flexible ion sensor was based on AgCl electrodes screen printed...

  • Article
  • Open Access
8 Citations
3,526 Views
10 Pages

A new class of solid-state miniaturised reference electrodes with a deep eutectic solvent as an alternate enhancement electrode system is described. A simple and accurate stable electrochemical sensor was prepared by developing a conventional referen...

  • Article
  • Open Access
9 Citations
4,055 Views
10 Pages

22 September 2022

Electrochemical aptamer-based sensors offer reagent-free and continuous analyte measurement but often suffer from poor longevity and potential drift even with a robust 3-electrode system. Presented here is a simple, software-enabled approach that tra...

  • Article
  • Open Access
14 Citations
4,671 Views
11 Pages

Two-Channel Graphene pH Sensor Using Semi-Ionic Fluorinated Graphene Reference Electrode

  • Dae Hoon Kim,
  • Woo Hwan Park,
  • Hong Gi Oh,
  • Dong Cheol Jeon,
  • Joon Mook Lim and
  • Kwang Soup Song

28 July 2020

A reference electrode is necessary for the working of ion-sensitive field-effect transistor (ISFET)-type sensors in electrolyte solutions. The Ag/AgCl electrode is normally used as a reference electrode. However, the Ag/AgCl reference electrode limit...

  • Article
  • Open Access
18 Citations
8,944 Views
13 Pages

Processes’ occurring at the Ag/AgCl/Cl, ([Fe(CN)6]3–/4–) ions interface study results are presented. Conditions are selected for the mixed salts’ precipitate formation on the silver surface. It has been shown that the potential of a silver screen-pr...

  • Article
  • Open Access
14 Citations
5,011 Views
13 Pages

A Redox Conjugated Polymer-Based All-Solid-State Reference Electrode

  • Ke Qu,
  • Mingxi Fang,
  • Shuwei Zhang,
  • Haiying Liu and
  • Xiangqun Zeng

25 October 2018

This work reports the design, synthesis, and characterization of a novel redox-active conjugated polyaniline containing quinone moiety as a solid state reference electrode. The union of electro-active quinone with π-conjugated polyaniline was crea...

  • Article
  • Open Access
10 Citations
4,523 Views
11 Pages

Valve-Actuator-Integrated Reference Electrode for an Ultra-Long-Life Rumen pH Sensor

  • Shogo Higuchi,
  • Hironao Okada,
  • Seiichi Takamatsu and
  • Toshihiro Itoh

25 February 2020

We demonstrated a newly developed Ag/AgCl reference electrode- with a valve-actuator for two years or longer rumen pH monitoring. Previous studies on pH sensors reported that the short lifetime of Ag/AgCl reference electrodes is caused by an outflow...

  • Article
  • Open Access
15 Citations
7,559 Views
20 Pages

Fabrication of a 3D-Printed Porous Junction for Ag|AgCl|gel-KCl Reference Electrode

  • Sarah May Sibug-Torres,
  • Lance P. Go and
  • Erwin P. Enriquez

Fused filament fabrication (FFF) is a 3D printing method that is attracting increased interest in the development of miniaturized electrochemical sensor systems due to its versatility, low cost, reproducibility, and capability for rapid prototyping....

  • Review
  • Open Access
370 Views
31 Pages

28 January 2026

Silicon nanowire field-effect transistors (Si NWFETs), thanks to their highly efficient integration into numerous electronic devices, represent promising tools for pH measurements and molecular biosensing due to their high sensitivity to ionic charge...

  • Article
  • Open Access
6 Citations
5,727 Views
11 Pages

7 March 2018

To improve the reference potential stability of on-chip amperometric sensors, we propose a novel integrated Ag/AgCl reference electrode structure. This structure can refresh the saturated potassium chloride filling solution surrounding the Ag/AgCl el...

  • Article
  • Open Access
71 Citations
18,148 Views
14 Pages

17 March 2015

In this study, we describe a novel solid-state thin-film Ag/AgCl reference electrode (SSRE) that was coated with a protective layer of graphene oxide (GO). This layer was prepared by drop casting a solution of GO on the Ag/AgCl thin film. The potenti...

  • Article
  • Open Access
15 Citations
9,661 Views
10 Pages

13 October 2017

The fabrication of miniaturized electrical biosensing devices can enable the rapid on-chip detection of biomarkers such as miRNA molecules, which is highly important in early-stage cancer detection. The challenge in realizing such devices remains in...

  • Article
  • Open Access
1 Citations
3,244 Views
25 Pages

To evaluate the long term corrosion potential stability of stainless steel (SS) in environmental water, the corrosion potential of SUS304, SUS316, SUS316L, and SUS430 was measured for 1 week in a solution of 0.9 mM NaHCO3 and 0.5 mM CaCl2, referred t...

  • Article
  • Open Access
20 Citations
4,644 Views
17 Pages

Development of New Simple Compositions of Silver Inks for the Preparation of Pseudo-Reference Electrodes

  • Jéssica R. Camargo,
  • Wilson S. Fernandes-Junior,
  • Déborah C. Azzi,
  • Raquel G. Rocha,
  • Lucas V. Faria,
  • Eduardo M. Richter,
  • Rodrigo A. A. Muñoz and
  • Bruno C. Janegitz

16 September 2022

Silver materials are known to present excellent properties, such as high electrical and thermal conductivity as well as chemical stability. Silver-based inks have drawn a lot of attention for being compatible with various substrates, which can be use...

  • Article
  • Open Access
6 Citations
3,422 Views
11 Pages

The Integration of Reference Electrode for ISFET Ion Sensors Using Fluorothiophenol-Treated rGO

  • Dae Hoon Kim,
  • Hae Shin Cho,
  • Jin Heung Kim,
  • Da Ae Jo,
  • Hong Gi Oh,
  • Byoung Kuk Jang and
  • Kwang Soup Song

5 January 2023

Ion-sensitive field-effect transistors (ISFETs) detect specific ions in solutions that enable straightforward, fast, and inexpensive sensors compared to other benchtop equipment. However, a conventional reference electrode (RE) such as Ag/AgCl is lim...

  • Article
  • Open Access
6 Citations
3,731 Views
15 Pages

29 March 2019

By combining traditional electrochemical tests including Tafel extension method and Mott-Schottky fitting, spectroscopic ellipsometry (SE) and a micro-region analysis technique, which is an integrated system of a scanning reference electrode techniqu...

  • Review
  • Open Access
20 Citations
17,507 Views
13 Pages

Unconventional Electrochemistry in Micro-/Nanofluidic Systems

  • Sahana Sarkar,
  • Stanley C. S. Lai and
  • Serge G. Lemay

Electrochemistry is ideally suited to serve as a detection mechanism in miniaturized analysis systems. A significant hurdle can, however, be the implementation of reliable micrometer-scale reference electrodes. In this tutorial review, we introduce t...

  • Article
  • Open Access
16 Citations
6,339 Views
23 Pages

13 June 2017

We present an innovative electrochemical probe for the monitoring of pH, redox potential and conductivity in near-field rocks of deep geological radioactive waste repositories. The probe is composed of a monocrystalline antimony electrode for pH sens...

  • Review
  • Open Access
1 Citations
965 Views
22 Pages

Advances in Reference Membranes for Potentiometric Sensing Applications

  • Martyna Drużyńska,
  • Nikola Lenar and
  • Beata Paczosa-Bator

6 December 2025

Accurate potentiometric sensing critically depends on the stability and reproducibility of the reference electrode potential. Conventional liquid-filled Ag/AgCl or calomel electrodes, though well-established, are poorly compatible with miniaturized,...

  • Article
  • Open Access
34 Citations
9,662 Views
17 Pages

Sol-Gel Deposition of Iridium Oxide for Biomedical Micro-Devices

  • Cuong M. Nguyen,
  • Smitha Rao,
  • Xuesong Yang,
  • Souvik Dubey,
  • Jeffrey Mays,
  • Hung Cao and
  • Jung-Chih Chiao

12 February 2015

Flexible iridium oxide (IrOx)-based micro-electrodes were fabricated on flexible polyimide substrates using a sol-gel deposition process for utilization as integrated pseudo-reference electrodes for bio-electrochemical sensing applications. The fabr...

  • Review
  • Open Access
199 Citations
23,299 Views
31 Pages

23 June 2009

Novel applications of online pH determinations at temperatures from -35 °C to 130 °C in technical and biological media, which are all but ideal aqueous solutions, require new approaches to pH monitoring. The glass electrode, introduced nearly hundred...

  • Article
  • Open Access
24 Citations
14,278 Views
10 Pages

A „Hybrid“ Thin-Film pH Sensor with Integrated Thick-Film Reference

  • Anette Simonis,
  • Thomas Krings,
  • Hans Lüth,
  • Joseph Wang and
  • Michael J. Schöning

2 November 2001

A reference electrode fabricated by means of thick-film technique is deposited onto a silicon substrate and combined with a thin-film pH sensor to a “hybrid” chip system. To evaluate the suitability of this combination, first investigations were carr...

  • Article
  • Open Access
3 Citations
2,794 Views
16 Pages

Online Fast Charging Model without Lithium Plating for Long-Dimensional Cells in Automotive Applications

  • Yu Wang,
  • Shuoyuan Mao,
  • Quanwei Chen,
  • Fei Chen,
  • Xue Zhang,
  • Minggao Ouyang,
  • Xuebing Han and
  • Yuejiu Zheng

22 November 2023

The internal negative electrode potential in lithium-ion batteries (LIBs) is intricately linked to the lithium-ion intercalation and plating reactions occurring within the cell. With the expansion of cell sizes, the internal negative electrode potent...

  • Article
  • Open Access
8 Citations
3,035 Views
12 Pages

11 January 2022

This work summarizes the electrochemical response of a salicylic acid-based carbon electrode for use as a novel solid-state reference electrode in a redox-based pH sensor. This novel reference produces a pH insensitive response over a range of pH 3&n...

  • Article
  • Open Access
2 Citations
5,481 Views
14 Pages

28 June 2021

This paper reports a novel miniaturized pseudo reference electrode (RE) design for biasing Ion Sensitive Field Effect Transistors (ISFETs). It eliminates the need for post-CMOS processing and can scale up in numbers with the CMOS scaling. The present...

  • Communication
  • Open Access
5 Citations
3,818 Views
11 Pages

19 July 2021

Intense interest in reference electrode design and fabrication has recently been enriched with the application of 3D printing of electrodes with salt-loaded PVC membranes. This type of material is attractive in sensor technology and is challenging to...

  • Article
  • Open Access
12 Citations
3,568 Views
12 Pages

Two–Dimensional Disposable Graphene Sensor to Detect Na+ Ions

  • Hong Gi Oh,
  • Dong Cheol Jeon,
  • Mahmudah Salwa Gianti,
  • Hae Shin Cho,
  • Da Ae Jo,
  • Muhammad Naufal Indriatmoko,
  • Byoung Kuk Jang,
  • Joon Mook Lim,
  • Seungmin Cho and
  • Kwang Soup Song

19 March 2021

The monitoring of Na+ ions distributed in the body has been indirectly calculated by the detection of Na+ ions in urine. We fabricated a two–dimensional (2D) Na+ ion sensor using a graphene ion–sensitive field–effect transistor (G–ISFET) and used flu...

  • Article
  • Open Access
23 Citations
10,705 Views
14 Pages

26 April 2010

A corrosion sensor for monitoring the corrosion state of cover mortar was developed. The sensor was tested in cement mortar, with and without the addition of chloride to simulate the adverse effects of chloride-contaminated environmental conditions o...

  • Article
  • Open Access
1,975 Views
19 Pages

Research on Quantitative Diagnosis of Dendrites Based on Titration Gas Chromatography Technology

  • Kai Yang,
  • Hongchang Cai,
  • Suran Li,
  • Yu Wang,
  • Xue Zhang,
  • Zhenxuan Wu,
  • Yilin Lai,
  • Minella Bezha,
  • Klara Bezha and
  • Xuning Feng
  • + 2 authors

17 May 2024

Lithium plating can cause capacity fade and thermal runaway safety issues in lithium-ion batteries. Therefore, accurately detecting the amount of lithium plating on the surface of the battery’s negative electrode is crucial for battery safety....

  • Article
  • Open Access
8 Citations
2,711 Views
9 Pages

The Stability of Analytes of Ionized Magnesium Concentration and Its Reference Range in Healthy Volunteers

  • Juhaina Salim Al-Maqbali,
  • Abdullah M. Al Alawi,
  • Zubaida Al-Falahi,
  • Henrik Falhammar,
  • Ibrahim Al-Zakwani and
  • Mohammed Al Za’abi

15 September 2023

This study aimed to determine the stability of refrigerated analytes of iMg concentration at different time intervals and to establish iMg reference range in a cohort of healthy Omani volunteers (≥18 years). The concentrations of iMg were measured...

  • Communication
  • Open Access
9 Citations
4,429 Views
9 Pages

20 March 2020

The use of concentrated aprotic electrolytes in lithium batteries provides numerous potential applications, including the use of high-voltage cathodes and Li-metal anodes. In this paper, we aim at understanding the effect of salt concentration on the...

  • Article
  • Open Access
22 Citations
9,822 Views
17 Pages

14 March 2013

Abstract: We report the fabrication and characterisation of the first graphene ring micro electrodes with the addition of a miniature concentric Ag/AgCl reference electrode. The graphene ring electrode is formed by dip coating fibre optics with grap...

  • Article
  • Open Access
22 Citations
11,537 Views
11 Pages

An In-Situ Reference Electrode Insertion Method for Commercial 18650-Type Cells

  • Limhi Somerville,
  • Stefania Ferrari,
  • Michael J. Lain,
  • Andrew McGordon,
  • Paul Jennings and
  • Rohit Bhagat

This work introduces a new method for inserting a Lithium reference electrode into commercially available 18650-type cells in order to obtain electrode potentials during cell operation. The proposed method is simple and requires limited equipment. Fu...

  • Proceeding Paper
  • Open Access
5 Citations
2,478 Views
5 Pages

Reference-Electrode Free pH Sensing Using Impedance Spectroscopy

  • Laura Folkertsma,
  • Lennart Gehrenkemper,
  • Jan Eijkel,
  • Karin Gerritsen and
  • Mathieu Odijk

30 November 2018

We present a reference-electrode free sensor able to measure both pH and conductivity

based on impedance spectroscopy. The electrode is made of a layer of indium-tin-oxide (ITO). The

impedance of this electrode at low frequencies depends on its double...

  • Article
  • Open Access
11 Citations
7,092 Views
14 Pages

6 April 2020

To realize an ultra-low-power and low-noise instrumentation amplifier (IA) for neural and biopotential signal sensing, we investigate two design techniques. The first technique uses a noise-efficient DC servo loop (DSL), which has been shown to be a...

  • Article
  • Open Access
13 Citations
4,720 Views
14 Pages

Realization of a PEDOT:PSS/Graphene Oxide On-Chip Pseudo-Reference Electrode for Integrated ISFETs

  • Marcel Tintelott,
  • Tom Kremers,
  • Sven Ingebrandt,
  • Vivek Pachauri and
  • Xuan Thang Vu

14 April 2022

A stable reference electrode (RE) plays a crucial role in the performance of an ion-sensitive field-effect transistor (ISFET) for bio/chemical sensing applications. There is a strong demand for the miniaturization of the RE for integrated sensor syst...

  • Article
  • Open Access
780 Views
22 Pages

This work demonstrates the use of SUS316L stainless steel as a new material for the fabrication of quasi-reference electrodes (QREs) intended to replace conventional reference electrodes (REs) in electrochemical sensors. The present study examined th...

  • Article
  • Open Access
23 Citations
5,700 Views
11 Pages

RuO2 pH Sensor with Super-Glue-Inspired Reference Electrode

  • Wade Lonsdale,
  • Magdalena Wajrak and
  • Kamal Alameh

6 September 2017

A pH-sensitive RuO2 electrode coated in a commercial cyanoacrylate adhesive typically exhibits very low pH sensitivity, and could be paired with a RuO2 working electrode as a differential type pH sensor. However, such sensors display poor performance...

  • Article
  • Open Access
2,221 Views
14 Pages

Microfabricated rGO/PANI Interdigitated Electrodes for Reference-Free, Label-Free pH Sensing on Flexible Substrates

  • Maryam Sepehri Gohar,
  • Ekin Asim Ozek,
  • Melih Can Tasdelen,
  • Burcu Arman Kuzubasoglu,
  • Yaser Vaheb and
  • Murat Kaya Yapici

27 November 2025

We present a flexible pH sensor which leverages the unique properties of reduced graphene oxide/polyaniline (rGO/PANI) composite films through an efficient and scalable hybrid microfabrication approach, wherein the rGO/PANI films are conformally coat...

of 18