Skip to Content

70 Results Found

  • Article
  • Open Access
21 Citations
5,156 Views
16 Pages

7 December 2021

In computed tomography (CT) images, the presence of metal artifacts leads to contaminated object structures. Theoretically, eliminating metal artifacts in the sinogram domain can correct projection deviation and provide reconstructed images that are...

(This article belongs to the Section Sensing and Imaging)
  • Review
  • Open Access
29 Citations
6,944 Views
21 Pages

Advances in Bone Joint Imaging-Metal Artifact Reduction

  • Sho Kohyama,
  • Yuichi Yoshii,
  • Yoshikazu Okamoto and
  • Takahito Nakajima

7 December 2022

Numerous types of metal implants have been introduced in orthopedic surgery and are used in everyday practice. To precisely evaluate the postoperative condition of arthroplasty or trauma surgery, periprosthetic infection, and the loosening of implant...

(This article belongs to the Section Medical Imaging and Theranostics)
  • Article
  • Open Access
1 Citations
752 Views
21 Pages

7 April 2026

Metal artifact reduction (MAR) remains a long-standing challenge in computed tomography (CT) reconstruction. Metallic implants introduce inconsistencies between the acquired projection data and the ideal Radon transform, resulting in severe streaking...

(This article belongs to the Special Issue Inverse Problems in Science and Engineering)
  • Article
  • Open Access
14 Citations
3,504 Views
20 Pages

6 September 2021

In this study, a novel combination of hybrid generative adversarial networks (GANs) comprising cycle-consistent GAN, pix2pix, and (mask pyramid network) MPN (CGpM-metal artifact reduction [MAR]), was developed using projection data to reduce metal ar...

(This article belongs to the Section Machine Learning and Artificial Intelligence in Diagnostics)
  • Article
  • Open Access
17 Citations
7,577 Views
15 Pages

Single-Energy Metal Artifact Reduction (SEMAR) in Ultra-High-Resolution CT Angiography of Patients with Intracranial Implants

  • Abdullah Jabas,
  • Mario Alberto Abello Mercado,
  • Sebastian Altmann,
  • Florian Ringel and ,
  • Christian Booz,
  • Andrea Kronfeld,
  • Antoine P. Sanner,
  • Marc A. Brockmann and
  • Ahmed E. Othman
  • + 4 authors+ 0 author

Purpose: To evaluate the effects of single-energy metal artifact reduction (SEMAR) on image quality of ultra-high-resolution CT-angiography (UHR-CTA) with intracranial implants after aneurysm treatment. Methods: Image quality of standard and SEMAR-re...

(This article belongs to the Section Medical Imaging and Theranostics)
  • Article
  • Open Access
2 Citations
5,926 Views
12 Pages

20 December 2019

In computed tomography (CT), metal implants increase the inconsistencies between the measured data and the linear assumption of the Radon transform made by the analytic CT reconstruction algorithm. The inconsistencies appear in the form of dark and b...

(This article belongs to the Special Issue Computer-aided Biomedical Imaging 2020: Advances and Prospects)
  • Article
  • Open Access
16 Citations
6,408 Views
14 Pages

Metal Artifact Reduction in Spectral X-ray CT Using Spectral Deep Learning

  • Matteo Busi,
  • Christian Kehl,
  • Jeppe R. Frisvad and
  • Ulrik L. Olsen

Spectral X-ray computed tomography (SCT) is an emerging method for non-destructive imaging of the inner structure of materials. Compared with the conventional X-ray CT, this technique provides spectral photon energy resolution in a finite number of e...

(This article belongs to the Section Computer Vision and Pattern Recognition)
  • Article
  • Open Access
4 Citations
1,770 Views
19 Pages

Hybrid-Frequency-Aware Mixture-of-Experts Method for CT Metal Artifact Reduction

  • Pengju Liu,
  • Hongzhi Zhang,
  • Chuanhao Zhang and
  • Feng Jiang

30 January 2026

In clinical CT imaging, high-density metallic implants often induce severe metal artifacts that obscure critical anatomical structures and degrade image quality, thereby hindering accurate diagnosis. Although deep learning has advanced CT metal artif...

(This article belongs to the Special Issue Structural Networks for Image Application)
  • Article
  • Open Access
1 Citations
2,754 Views
9 Pages

25 March 2022

We investigated the role of metal artifact reduction by taking 3D print impressions using 3D data of Computed Tomography (CT) images based on the algorithm applied. We manufactured a phantom of a human mandible tooth made of gypsum and nickel alloy t...

(This article belongs to the Topic Material and Process Innovations for 3D Printing Applications)
  • Article
  • Open Access
3 Citations
2,339 Views
10 Pages

Feasibility of In Vivo Metal Artifact Reduction in Contrast-Enhanced Dedicated Spiral Breast Computed Tomography

  • Matthias Wetzl,
  • Evelyn Wenkel,
  • Chrisitan Steiding,
  • Veikko Ruth and ,
  • Julius Emons,
  • Martin N. Wasser,
  • Michael Uder and
  • Sabine Ohlmeyer
  • + 3 authors+ 0 author

26 September 2023

Background: Radiopaque breast markers cause artifacts in dedicated spiral breast-computed tomography (SBCT). This study investigates the extent of artifacts in different marker types and the feasibility of reducing artifacts through a metal artifact...

(This article belongs to the Special Issue Advances in Diagnostic Medical Imaging in 2023)
  • Article
  • Open Access
1,757 Views
23 Pages

Unsupervised Metal Artifact Reduction in Dental CBCT Using Fine-Tuned Cycle-Consistent Adversarial Networks

  • Thamindu Chamika,
  • Sithum N. A. Dhanapala,
  • Sasindu Nimalaweera,
  • Maheshi B. Dissanayake and
  • Ruwan D. Jayasinghe

17 April 2026

Metal artifacts generated by dental implants significantly degrade cone-beam computed tomography (CBCT) volumes, obscuring critical anatomical structures and compromising diagnostic precision. To address this, an unsupervised deep learning framework...

  • Article
  • Open Access
7 Citations
3,258 Views
14 Pages

Clinical Evaluation of an Innovative Metal-Artifact-Reduction Algorithm in FD-CT Angiography in Cerebral Aneurysms Treated by Endovascular Coiling or Surgical Clipping

  • Felix Eisenhut,
  • Manuel Alexander Schmidt,
  • Alexander Kalik,
  • Tobias Struffert and ,
  • Julian Feulner,
  • Sven-Martin Schlaffer,
  • Michael Manhart,
  • Arnd Doerfler and
  • Stefan Lang
  • + 4 authors+ 0 author

Treated cerebral aneurysms (IA) require follow-up imaging to ensure occlusion. Metal artifacts complicate radiologic assessment. Our aim was to evaluate an innovative metal-artifact-reduction (iMAR) algorithm for flat-detector computed tomography ang...

(This article belongs to the Special Issue Advancements in Neuroimaging)
  • Article
  • Open Access
11 Citations
3,561 Views
10 Pages

Detectability of Head and Neck Cancer via New Computed Tomography Reconstruction Tools including Iterative Reconstruction and Metal Artifact Reduction

  • Daniel Troeltzsch,
  • Seyd Shnayien,
  • Max Heiland,
  • Kilian Kreutzer and ,
  • Jan-Dirk Raguse,
  • Bernd Hamm and
  • Stefan M. Niehues
  • + 2 authors+ 0 author

21 November 2021

State-of-the-art technology in Computed Tomography (CT) includes iterative reconstruction algorithms (IR) and metal artefact reduction (MAR) techniques. The objective of the study is to show the benefits of this technology for the detection of primar...

(This article belongs to the Section Medical Imaging and Theranostics)
  • Article
  • Open Access
8 Citations
4,086 Views
9 Pages

A Quantitative Evaluation of the Effectiveness of the Metal Artifact Reduction Algorithm in Cone Beam Computed Tomographic Images with Stainless Steel Orthodontic Brackets and Arch Wires: An Ex Vivo Study

  • Mojgan Shavakhi,
  • Parisa Soltani,
  • Golnaz Aghababaee,
  • Romeo Patini and ,
  • Niccolò Giuseppe Armogida,
  • Gianrico Spagnuolo and
  • Alessandra Valletta
  • + 2 authors+ 0 author

The presence of high-density and high-atomic number materials results in the generation of artifacts in cone beam computed tomographic (CBCT) images. To minimize artifacts in CBCT images, the metal artifact reduction (MAR) tool was developed. This st...

(This article belongs to the Special Issue Deep Learning for Medical Imaging Diagnosis)
  • Article
  • Open Access
9 Citations
3,871 Views
9 Pages

Accuracy Assessment of Percutaneous Pedicle Screw Placement Using Cone Beam Computed Tomography with Metal Artifact Reduction

  • Yann Philippe Charles,
  • Rawan Al Ansari,
  • Arnaud Collinet,
  • Pierre De Marini and ,
  • Jean Schwartz,
  • Rami Nachabe,
  • Dirk Schäfer,
  • Bernhard Brendel,
  • Afshin Gangi and
  • Roberto Luigi Cazzato
  • + 5 authors+ 0 author

18 June 2022

Metal artifact reduction (MAR) algorithms are used with cone beam computed tomography (CBCT) during augmented reality surgical navigation for minimally invasive pedicle screw instrumentation. The aim of this study was to assess intra- and inter-obser...

(This article belongs to the Section Biomedical Sensors)
  • Article
  • Open Access
3 Citations
4,966 Views
19 Pages

The Nature of Metal Artifacts in X-ray Computed Tomography and Their Reduction by Optimization of Tomography Systems Parameters

  • Sergey Pavlovich Osipov,
  • Sergei Vladimirovich Chakhlov,
  • Vadim Yurevich Zhvyrblia,
  • Dmitry Andreevich Sednev and ,
  • Oleg Sergeyevich Osipov and
  • Eugeny Yurevich Usachev
  • + 1 author+ 0 author

19 February 2023

A significant gap in the known methods for assessing the levels of metal artifacts in X-ray computed tomography and approaches to their reduction is an almost complete disregard for the physical nature of this artifact—the proximity to zero of...

(This article belongs to the Special Issue Application of X-ray Computed Tomography)
  • Article
  • Open Access
1,334 Views
13 Pages

Ex Vivo Quantitative Evaluation of Beam Hardening Artifacts at Various Implant Locations in Cone-Beam Computed Tomography Using Metal Artifact Reduction and Noise Reduction Techniques

  • Cengiz Evli,
  • Merve Önder,
  • Ruben Pauwels,
  • Mehmet Hakan Kurt and ,
  • İsmail Doruk Koçyiğit,
  • Gökhan Yazıcı and
  • Kaan Orhan
  • + 2 authors+ 0 author

15 December 2025

Purposes: Beam hardening artifacts caused by dental implants remain one of the most significant limitations of cone-beam computed tomography (CBCT), often compromising the evaluation of peri-implant bone and potentially masking critical diagnostic fi...

(This article belongs to the Special Issue Advances in Oral and Maxillofacial Imaging)
  • Article
  • Open Access
22 Citations
6,042 Views
14 Pages

The Impact of AI on Metal Artifacts in CBCT Oral Cavity Imaging

  • Róża Wajer,
  • Adrian Wajer,
  • Natalia Kazimierczak,
  • Justyna Wilamowska and
  • Zbigniew Serafin

Objective: This study aimed to assess the impact of artificial intelligence (AI)-driven noise reduction algorithms on metal artifacts and image quality parameters in cone-beam computed tomography (CBCT) images of the oral cavity. Materials and Method...

(This article belongs to the Special Issue Advances in Oral and Maxillofacial Radiology)
  • Article
  • Open Access
9 Citations
4,849 Views
18 Pages

Dual-Energy Computed Tomography Applications to Reduce Metal Artifacts in Hip Prostheses: A Phantom Study

  • Daniele Conti,
  • Fabio Baruffaldi,
  • Paolo Erani,
  • Anna Festa and ,
  • Stefano Durante and
  • Miriam Santoro
  • + 1 author+ 0 author

Metal components of hip prostheses cause severe artifacts in CT images, influencing diagnostic accuracy. Metal artifact reduction (MAR) software and virtual monoenergetic reconstructions on dual-energy CT (DECT) systems are possible solutions that sh...

(This article belongs to the Section Medical Imaging and Theranostics)
  • Article
  • Open Access
20 Citations
10,946 Views
15 Pages

23 January 2023

Metal artifacts in dental computed tomography (CT) images, caused by highly X-ray absorbing objects, such as dental implants or crowns, often more severely compromise image readability than in medical CT images. Since lower tube voltages are used for...

(This article belongs to the Section Biosensors)
  • Article
  • Open Access
17 Citations
4,592 Views
12 Pages

Metal Artifact Reduction Sequences MRI: A Useful Reference for Preoperative Diagnosis and Debridement Planning of Periprosthetic Joint Infection

  • Changyu Huang,
  • Yang Chen,
  • Haiqi Ding,
  • Zida Huang and ,
  • Chaofan Zhang,
  • Wenbo Li,
  • Xi Liu,
  • Zhanhai Tu,
  • Wenming Zhang and
  • Xinyu Fang
  • + 5 authors+ 0 author

27 July 2022

The diagnosis and treatment of periprosthetic joint infection (PJI) is complex and the use of MRI in PJI is gaining attention from orthopedic surgeons as MR technology continues to advance. This study aimed to investigate whether metal artefact reduc...

(This article belongs to the Special Issue Recent Advances in Arthroplasty - Part II)
  • Review
  • Open Access
19 Citations
4,958 Views
13 Pages

Potential Benefits of Photon-Counting CT in Dental Imaging: A Narrative Review

  • Chiara Zanon,
  • Alessia Pepe,
  • Filippo Cademartiri,
  • Costanza Bini and ,
  • Erica Maffei,
  • Emilio Quaia,
  • Edoardo Stellini and
  • Adolfo Di Fiore
  • + 3 authors+ 0 author

22 April 2024

Background/Objectives: Advancements in oral imaging technology are continually shaping the landscape of dental diagnosis and treatment planning. Among these, photon-counting computed tomography (PCCT), introduced in 2021, has emerged as a promising,...

(This article belongs to the Special Issue Current Trends and Future Directions in Prosthetic and Implant Dentistry in the Digital Era, 2nd Edition)
  • Review
  • Open Access
86 Views
26 Pages

Photon-Counting CT in Oral and Maxillofacial Imaging: Clinical Applications, Dose Efficiency, and Future Perspectives

  • Atanaz Darvizeh,
  • Fatemeh Darvizeh,
  • Luigi Calegari,
  • Arosh S. Perera Molligoda Arachchige and
  • Cinzia Maspero

2 November 2026

Photon-counting computed tomography (PCCT) is an emerging imaging technology that combines ultra-high spatial resolution, improved dose efficiency, reduced electronic noise, and intrinsic spectral imaging. These characteristics are particularly relev...

(This article belongs to the Special Issue Functional Parameters in Quantitative CT: Clinical Significance and Diagnostic Applications)
  • Article
  • Open Access
1 Citations
749 Views
14 Pages

Validation of Synthetic Megavoltage Computed Tomography (MVCT) for Dose Calculation in Radiotherapy Treatment Planning

  • Aurora Corso,
  • Niki Martinel,
  • Mubashara Rehman,
  • Joseph Stancanello and ,
  • Christian Micheloni,
  • Cristian Deana,
  • Cristina Cappelletto,
  • Paola Chiovati,
  • Riccardo Spizzo and
  • Michele Avanzo
  • + 7 authors+ 2 authors

14 May 2026

Background/Objectives: Dental metallic implants cause severe streaking artifacts in kilovoltage CT (kVCT), compromising dose calculation in radiotherapy (RT) treatment planning. The purpose of this study is to assess the dosimetric agreement of synth...

(This article belongs to the Special Issue AI-Enhanced Radiotherapy in Oncology: Optimization from Planning to Clinical Impact)
  • Interesting Images
  • Open Access
2 Citations
2,401 Views
4 Pages

Pedicle Screw Pseudofracture on Computed Tomography Secondary to Metal Artifact Reduction

  • Shuliang Ge,
  • Naresh Kumar and
  • James Thomas Patrick Decourcy Hallinan

Metal artifact reduction (MAR) algorithms are commonly used in computed tomography (CT) scans where metal implants are involved. However, MAR algorithms also have the potential to create new artifacts in reconstructed images. We present a case of a s...

(This article belongs to the Section Medical Imaging and Theranostics)
  • Review
  • Open Access
36 Citations
12,801 Views
33 Pages

State-of-the-Art Imaging Techniques in Metastatic Spinal Cord Compression

  • Tricia Kuah,
  • Balamurugan A. Vellayappan,
  • Andrew Makmur,
  • Shalini Nair and ,
  • Junda Song,
  • Jiong Hao Tan,
  • Naresh Kumar,
  • Swee Tian Quek and
  • James Thomas Patrick Decourcy Hallinan
  • + 4 authors+ 0 author

5 July 2022

Metastatic Spinal Cord Compression (MSCC) is a debilitating complication in oncology patients. This narrative review discusses the strengths and limitations of various imaging modalities in diagnosing MSCC, the role of imaging in stereotactic body ra...

(This article belongs to the Special Issue Treatment of Bone Metastases including Metastatic Spinal Cord Compression)
  • Article
  • Open Access
14 Citations
9,681 Views
15 Pages

End-to-End Deep Learning CT Image Reconstruction for Metal Artifact Reduction

  • Dominik F. Bauer,
  • Constantin Ulrich,
  • Tom Russ,
  • Alena-Kathrin Golla and ,
  • Lothar R. Schad and
  • Frank G. Zöllner
  • + 1 author+ 0 author

31 December 2021

Metal artifacts are common in CT-guided interventions due to the presence of metallic instruments. These artifacts often obscure clinically relevant structures, which can complicate the intervention. In this work, we present a deep learning CT recons...

(This article belongs to the Special Issue Deep Neural Networks in Medical Imaging)
  • Review
  • Open Access
3 Citations
2,901 Views
24 Pages

Background/Objectives: Computed tomography remains the reference standard for assessing lumbar interbody fusion, yet significant methodological heterogeneity, documented across more than 250 different assessment combinations, directly impacts treatme...

(This article belongs to the Special Issue Contemporary Spine Diagnostics and Management)
  • Article
  • Open Access
2 Citations
4,024 Views
8 Pages

Impact of Different Metal Artifact Reduction Techniques on Attenuation Correction of Normal Organs in 18F-FDG-PET/CT

  • Janna Morawitz,
  • Ole Martin,
  • Johannes Boos,
  • Lino M. Sawicki and ,
  • Katrin Wingendorf,
  • Martin Sedlmair,
  • Eduards Mamlins,
  • Christina Antke,
  • Gerald Antoch and
  • Benedikt M. Schaarschmidt
  • + 5 authors+ 0 author

Purpose: To evaluate the impact of different metal artifact reduction algorithms on Hounsfield units (HU) and the standardized uptake value (SUV) in normal organs in patients with different metal implants. Methods: This study prospectively included 6...

(This article belongs to the Topic Medical Image Analysis)
  • Article
  • Open Access
1 Citations
3,718 Views
14 Pages

Metallic Artifact Reduction in Midfacial CT Scans Using Patient-Specific Polymer Implants Enhances Image Quality

  • Julian Lommen,
  • Lara Schorn,
  • Christoph Sproll,
  • Valentin Kerkfeld and ,
  • Adem Aksu,
  • Frank Reinauer,
  • Norbert R. Kübler,
  • Wilfried Budach,
  • Majeed Rana and
  • Bálint Tamaskovics
  • + 5 authors+ 0 author

28 January 2023

Midfacial reconstruction after tumor resection surgery is commonly conducted by using autologous bone grafts or alloplastic implants. Titanium is the most frequently used osteosynthesis material in these cases but causes disturbing metallic artifacts...

(This article belongs to the Special Issue Personalized Medicine in Head and Neck Cancer)
  • Article
  • Open Access
335 Views
13 Pages

Metal Artifact Reduction in Oral Cavity MDCT Using Dental Overlays and the O-MAR Algorithm

  • Svetlana Antic,
  • Maja Lezaja Zebic,
  • Jovana Kuzmanovic Pficer,
  • Djurdja Bracanovic and ,
  • Aleksa Janovic,
  • Biljana Markovic Vasiljkovic and
  • Drago B. Jelovac
  • + 2 authors+ 0 author

7 September 2026

Background/Objectives: To evaluate the impact of dental laboratory material overlays on metal artifact reduction in multidetector computed tomography (MDCT) of the oral cavity across different CT protocols and reconstruction algorithms. Methods: An a...

(This article belongs to the Special Issue Recent Achievements in Oral and Maxillofacial Radiology)
  • Systematic Review
  • Open Access
2,191 Views
12 Pages

Dual-Energy Computed Tomography, a New Metal Artifact Reduction Technique for Total Hip Arthroplasty: Is There a Light in the Darkness?

  • Andrea Coppola,
  • Luigi Tessitore,
  • Chiara Macina,
  • Filippo Piacentino and ,
  • Federico Fontana,
  • Andrea Pautasso,
  • Velio Ascenti,
  • Roberto Minici,
  • Domenico Laganà and
  • Fabio D’Angelo
  • + 8 authors+ 3 authors

26 March 2025

Background/Objectives: To evaluate dual-energy computed tomography (DECT) in comparison with conventional CT for periprosthetic bone and surrounding soft tissues in total hip arthroplasty (THA). Methods: Two authors independently screened titles and...

(This article belongs to the Section Nuclear Medicine & Radiology)
  • Review
  • Open Access
23 Citations
3,527 Views
16 Pages

Review of Clinical Applications of Dual-Energy CT in Patients after Endovascular Aortic Repair

  • Wojciech Kazimierczak,
  • Natalia Kazimierczak and
  • Zbigniew Serafin

18 December 2023

Abdominal aortic aneurysms (AAAs) are a significant cause of mortality in developed countries. Endovascular aneurysm repair (EVAR) is currently the leading treatment method for AAAs. Due to the high sensitivity and specificity of post-EVAR complicati...

(This article belongs to the Special Issue Endovascular Aortic Interventions and Aneurysm Repair: Recent Advances and Future Prospects)
  • Article
  • Open Access
2 Citations
1,987 Views
14 Pages

26 October 2024

The topography of surfaces produced by metal additive manufacturing is a challenge for optical measurement systems such as focus variation microscopes. These irregularities can lead to artifacts, such as incorrectly measured protrusions or spikes, ha...

(This article belongs to the Special Issue Optical Technologies for Measurement and Metrology)
  • Article
  • Open Access
1,822 Views
16 Pages

11 July 2025

High-density component-induced metal artifacts in industrial computed tomography (CT) severely impair image quality and make further analysis more difficult. To suppress artifacts and improve image quality, this research suggests a practical approach...

  • Article
  • Open Access
3 Citations
6,860 Views
15 Pages

15 September 2022

This study evaluates the clinical usefulness of the images obtained after applying mDixon (O-MAR), CS-SEMAC (SPIR), and STIR techniques to Pig L-Spine Phantom and transplant patients according to the difference in the reduction in metal artifacts and...

(This article belongs to the Special Issue New Advances in Magnetic Resonance Imaging (MRI))
  • Article
  • Open Access
1,782 Views
14 Pages

5 November 2024

Artifacts in computed tomography and X-ray microtomography are image distortions caused by various factors. Some can be reduced before or during the examination, while others are removed algorithmically after image acquisition. The latter group inclu...

(This article belongs to the Section Sensing and Imaging)
  • Article
  • Open Access
538 Views
23 Pages

Effect of the Internal Architecture of Titanium Interbody Cages on Signal Loss Artifacts at 3.0 T Magnetic Resonance Imaging

  • Katarzyna Skierbiszewska,
  • Krzysztof Jankowski,
  • Tomasz Jasiński,
  • Bernard Turek and ,
  • Marta Borowska and
  • Małgorzata Domino
  • + 1 author+ 0 author

21 May 2026

Interbody cages are employed in spinal surgery to enhance segmental stability and facilitate decompression of the spinal cord and nerve roots. As these devices are commonly made of titanium, they produce metal-induced artifacts during postsurgical ma...

(This article belongs to the Special Issue Advanced Techniques and Applications in Magnetic Resonance Imaging)
  • Article
  • Open Access
7 Citations
4,018 Views
10 Pages

Comparative Evaluation of Artifacts Originated by Four Different Post Materials Using Different CBCT Settings

  • Dilek Helvacioglu-Yigit,
  • Umut Seki,
  • Sebnem Kursun-Cakmak,
  • Husniye Demirturk Kocasarac and
  • Maharaj Singh

13 December 2022

The aim of this study was to evaluate whether cone beam computed tomography (CBCT) images in the presence of four different post materials, obtained from different kVps with varying resolutions and varying metal artifact reduction (MAR) algorithms, d...

  • Article
  • Open Access
7 Citations
4,844 Views
16 Pages

12 April 2024

Industrial computed tomography (CT) images reconstructed directly from projection data using the filtered back projection (FBP) method exhibit strong metal artifacts due to factors such as beam hardening, scatter, statistical noise, and deficiencies...

  • Systematic Review
  • Open Access
3 Citations
2,677 Views
23 Pages

Artificial Intelligence for Artifact Reduction in Cone Beam Computed Tomographic Images: A Systematic Review

  • Parisa Soltani,
  • Gianrico Spagnuolo,
  • Francesca Angelone,
  • Asal Rezaeiyazdi and ,
  • Mehdi Mohammadzadeh,
  • Giuseppe Maisto,
  • Amirhossein Moaddabi,
  • Mariangela Cernera,
  • Niccolò Giuseppe Armogida and
  • Alfonso Maria Ponsiglione
  • + 6 authors+ 1 author

30 December 2025

Cone beam computed tomography (CBCT) allows for rapid and accessible acquisition of three-dimensional images with a lower radiation dose compared to conventional computed tomography (CT) scans. However, the quality of CBCT images is limited by a vari...

(This article belongs to the Special Issue Advances in the Detection and Diagnosis of Cancer and Their Clinical Applications)
  • Article
  • Open Access
5 Citations
3,615 Views
16 Pages

Prospective Evaluation of Magnetic Resonance Imaging Features of Magnesium-Based Alloy Screw Resorption in Pediatric Fractures

  • Stephan L. Waelti,
  • Simon Wildermuth,
  • Erik P. Willems,
  • Tim Fischer and ,
  • Tobias J. Dietrich,
  • Sebastian Leschka,
  • Christoph Matissek,
  • Thomas Krebs and
  • Stefan Markart
  • + 4 authors+ 0 author

21 April 2023

Background: The resorption of magnesium-based alloy bioabsorbable screws results in the release of hydrogen gas, which can mimic infection and enter the growth plate. The screw itself and the released gas may also affect image quality. Objective: The...

(This article belongs to the Section Nuclear Medicine & Radiology)
  • Article
  • Open Access
19 Citations
9,067 Views
20 Pages

Complete Ring Artifacts Reduction Procedure for Lab-Based X-ray Nano CT Systems

  • Jakub Šalplachta,
  • Tomáš Zikmund,
  • Marek Zemek,
  • Adam Břínek and ,
  • Yoshihiro Takeda,
  • Kazuhiko Omote and
  • Jozef Kaiser
  • + 2 authors+ 0 author

1 January 2021

In this article, we introduce a new ring artifacts reduction procedure that combines several ideas from existing methods into one complex and robust approach with a goal to overcome their individual weaknesses and limitations. The procedure different...

(This article belongs to the Special Issue Tomography Sensing Technologies)
  • Article
  • Open Access
8 Citations
4,005 Views
16 Pages

X-ray tomography is often affected by noise and artifacts during the reconstruction process, such as detector offset, calibration errors, metal artifacts, etc. Conventional algorithms, including FDK and SART, are unable to satisfy the sampling theore...

(This article belongs to the Special Issue Nature Inspired Computing and Optimisation)
  • Article
  • Open Access
3 Citations
3,505 Views
11 Pages

19 August 2024

Computed tomography (CT) is one of the fundamental imaging modalities used in medicine, allowing for the acquisition of accurate cross-sectional images of internal body tissues. However, during the acquisition and reconstruction process, various arti...

(This article belongs to the Special Issue Novel Research on Image and Video Processing Technology)
  • Article
  • Open Access
863 Views
11 Pages

Impact of Metal Artifact Reduction on the Diagnosis of Peri-Implant Defects Around Zirconia and Titanium Implants: A CBCT Pilot Study

  • Mahsa Moannaei,
  • Mojdeh Mehdizadeh,
  • Farnaz Mirrashidi,
  • Mohammad Hossein Manouchehri and ,
  • Sepehr Naghdi,
  • Amirhossein Moaddabi,
  • Nima Malek Hosseini,
  • Gianrico Spagnuolo,
  • Francesco Giordano and
  • Parisa Soltani
  • + 5 authors+ 0 author

3 July 2026

Background/Objectives: Metal artifacts from dental implants degrade CBCT image quality and may impair detection of peri-implant bone defects. Zirconia implants produce stronger artifacts than titanium due to its higher atomic number. This study evalu...

  • Letter
  • Open Access
10 Citations
6,174 Views
13 Pages

Design of an Ultrasound Transceiver ASIC with a Switching-Artifact Reduction Technique for 3D Carotid Artery Imaging

  • Taehoon Kim,
  • Fabian Fool,
  • Djalma Simoes dos Santos,
  • Zu-Yao Chang and ,
  • Emile Noothout,
  • Hendrik J. Vos,
  • Johan G. Bosch,
  • Martin D. Verweij,
  • Nico de Jong and
  • Michiel A. P. Pertijs
  • + 5 authors+ 0 author

29 December 2020

This paper presents an ultrasound transceiver application-specific integrated circuit (ASIC) directly integrated with an array of 12 × 80 piezoelectric transducer elements to enable next-generation ultrasound probes for 3D carotid artery imagin...

(This article belongs to the Special Issue Ultrasonic Systems for Biomedical Sensing)
  • Article
  • Open Access
5 Citations
4,361 Views
7 Pages

The Relationship between the Contouring Time of the Metal Artifacts Area and Metal Artifacts in Head and Neck Radiotherapy

  • Kouji Katsura,
  • Satoshi Tanabe,
  • Hisashi Nakano,
  • Madoka Sakai and ,
  • Atsushi Ohta,
  • Motoki Kaidu,
  • Marie Soga,
  • Taichi Kobayashi,
  • Masaki Takamura and
  • Takafumi Hayashi
  • + 5 authors+ 0 author

11 January 2023

(1) Background: The impacts of metal artifacts (MAs) on the contouring workload for head and neck radiotherapy have not yet been clarified. Therefore, this study evaluated the relationship between the contouring time of the MAs area and MAs on head a...

(This article belongs to the Section Cancer Imaging)
  • Article
  • Open Access
2 Citations
2,628 Views
25 Pages

An Analysis of Arrays with Irregular Apertures in MEMS Smart Glasses for the Improvement of Clear View

  • Roland Donatiello,
  • Mustaqim Siddi Que Iskhandar,
  • Md Kamrul Hasan,
  • Philipp Kästner and ,
  • Muhammad Hasnain Qasim,
  • Jiahao Chen,
  • Shilby Baby,
  • Basma Elsaka,
  • Guilin Xu and
  • Hartmut Hillmer
  • + 5 authors+ 0 author

31 January 2025

An innovative glass substrate surface technology including integrated micro-electro-mechanical systems (MEMS) is presented as an advanced light modulation, heat control, and energy management system. This smart technology is based on millions of meta...

(This article belongs to the Collection Optical MEMS: Design, Fabrication, Control, Modeling and Developments)
  • Communication
  • Open Access
510 Views
9 Pages

19 August 2026

Patients with implanted cardiac devices are a rapidly growing imaging population, and electrocardiogram-gated cardiac computed tomography (CT) is increasingly used to characterize device geometry, multi-device relationships, and dynamic behavior acro...

(This article belongs to the Section Medical Imaging)

of 2