Skip to Content

38 Results Found

  • Article
  • Open Access
99 Citations
11,634 Views
13 Pages

21 February 2020

High-density surface electromyography (HD-sEMG) and deep learning technology are becoming increasingly used in gesture recognition. Based on electrode grid data, information can be extracted in the form of images that are generated with instant value...

(This article belongs to the Section Biomedical Sensors)
  • Review
  • Open Access
72 Citations
13,215 Views
31 Pages

Fundamental Concepts of Bipolar and High-Density Surface EMG Understanding and Teaching for Clinical, Occupational, and Sport Applications: Origin, Detection, and Main Errors

  • Isabella Campanini,
  • Andrea Merlo,
  • Catherine Disselhorst-Klug,
  • Luca Mesin and ,
  • Silvia Muceli and
  • Roberto Merletti
  • + 1 author+ 0 author

30 May 2022

Surface electromyography (sEMG) has been the subject of thousands of scientific articles, but many barriers limit its clinical applications. Previous work has indicated that the lack of time, competence, training, and teaching is the main barrier to...

(This article belongs to the Section Biosensors)
  • Article
  • Open Access
2 Citations
2,320 Views
15 Pages

Antagonist Activation Measurement in Triceps Surae Using High-Density and Bipolar Surface EMG in Chronic Hemiparesis

  • Mouna Ghédira,
  • Taian Martins Vieira,
  • Giacinto Luigi Cerone,
  • Marco Gazzoni and ,
  • Jean-Michel Gracies and
  • Emilie Hutin
  • + 1 author+ 0 author

7 June 2024

After a stroke, antagonist muscle activation during agonist command impedes movement. This study compared measurements of antagonist muscle activation using surface bipolar EMG in the gastrocnemius medialis (GM) and high-density (HD) EMG in the GM an...

(This article belongs to the Special Issue Sensors for Recognition, Analysis, Assistance, and Training of Gait in Neurologic Disorders)
  • Article
  • Open Access
1,043 Views
18 Pages

Objective Biomarker Development for Parameter Optimization in Neuromodulation Using High-Density EMG Temporal and Spatial Features

  • Shirin Madarshahian,
  • Nikoo Javadpour,
  • Michael Trakhtorchuck,
  • Tatiana Guerrero-David and ,
  • Kristin Gustafson,
  • James S. Harrop,
  • Caio M. Matias,
  • M. J. Mulcahey,
  • Alessandro Napoli and
  • Mijail Serruya
  • + 6 authors+ 1 author

Transcutaneous spinal cord stimulation (tSCS) is a promising neuromodulation approach for motor recovery after spinal cord injury (SCI), yet clinical programming remains largely dependent on subjective parameter selection. This study evaluated high-d...

(This article belongs to the Special Issue Advancements in Physical Therapy and Rehabilitation: Neuromodulation, MRI-Based Neuroimaging and Functional Restoration Devices)
  • Article
  • Open Access
7 Citations
3,308 Views
18 Pages

Hand Gesture Recognition Based on High-Density Myoelectricity in Forearm Flexors in Humans

  • Xiaoling Chen,
  • Huaigang Yang,
  • Dong Zhang,
  • Xinfeng Hu and
  • Ping Xie

19 June 2024

Electromyography-based gesture recognition has become a challenging problem in the decoding of fine hand movements. Recent research has focused on improving the accuracy of gesture recognition by increasing the complexity of network models. However,...

(This article belongs to the Section Biomedical Sensors)
  • Article
  • Open Access
17 Citations
10,611 Views
12 Pages

Wireless sEMG System with a Microneedle-Based High-Density Electrode Array on a Flexible Substrate

  • Minjae Kim,
  • Gangyong Gu,
  • Kyoung Je Cha,
  • Dong Sung Kim and
  • Wan Kyun Chung

30 December 2017

Surface electromyography (sEMG) signals reflect muscle contraction and hence, can provide information regarding a user’s movement intention. High-density sEMG systems have been proposed to measure muscle activity in small areas and to estimate comple...

(This article belongs to the Special Issue Biomedical Sensors and Systems 2017)
  • Systematic Review
  • Open Access
5 Citations
2,117 Views
19 Pages

Electromyography After Total Hip Arthroplasty: A Systematic Review of Neuromuscular Alterations and Functional Movement Patterns

  • Maria Cesarina May,
  • Andrea Zanirato,
  • Luca Puce,
  • Eugenio Giannarelli and ,
  • Carlo Trompetto,
  • Lucio Marinelli and
  • Matteo Formica
  • + 2 authors+ 0 author

5 January 2026

Background: Electromyography (EMG) is increasingly used to characterize neuromuscular alterations after total hip arthroplasty (THA), yet available evidence remains fragmented and inconsistent. This systematic review synthesizes postoperative EMG fin...

(This article belongs to the Special Issue Total Hip Arthroplasty Today: Trends, Challenges, and Future Directions)
  • Communication
  • Open Access
7 Citations
4,005 Views
10 Pages

3 March 2021

Surface electromyography (EMG) has been used to estimate muscle work and physiological burden of the whole body during human movements. However, there are spatial variations in surface EMG responses within individual muscles. The aim of this study wa...

(This article belongs to the Section Biomedical Sensors)
  • Article
  • Open Access
1 Citations
1,020 Views
15 Pages

Precise monitoring of forearm muscle groups is crucial for decoding motor intentions in human–machine interfaces (HMIs) and rehabilitation. However, traditional surface electromyography (sEMG) electrodes face significant challenges in densely p...

(This article belongs to the Section Biosignal Processing)
  • Article
  • Open Access
360 Citations
21,530 Views
22 Pages

24 February 2017

High-density surface electromyography (HD-sEMG) is to record muscles’ electrical activity from a restricted area of the skin by using two dimensional arrays of closely spaced electrodes. This technique allows the analysis and modelling of sEMG signal...

(This article belongs to the Section Physical Sensors)
  • Article
  • Open Access
8 Citations
5,540 Views
16 Pages

20 March 2022

Superficial skeletal muscle activation is associated with an electric activity. Bidimensional High-Density Surface Electromyography (HD-sEMG) is a non-invasive technique that uses a grid of equally spaced electrodes applied on the skin surface to det...

(This article belongs to the Special Issue Integrating Wearable Technologies in Equine Sports Medicine: Recent Advances for Diagnosis and Treatment)
  • Article
  • Open Access
800 Views
20 Pages

Design and Measured Assessment of a MOS-Only, Capacitorless, Miniature 64-Channel Headstage Circuit for High-Density Surface Electromyography

  • Simos Koutsoftidis,
  • Georgios Gryparis,
  • Maciej Zajaczkowski,
  • Guang Yang and ,
  • Konstantinos Glaros,
  • Dario Farina and
  • Emmanuel M. Drakakis
  • + 2 authors+ 0 author

2 July 2026

Background: We present a miniature (30 × 34 mm) 64-channel data acquisition headstage optimized for high-density surface electromyography. Methods: The headstage is made up of a multi-channel ASIC analogue front-end utilizing only MOS transisto...

(This article belongs to the Special Issue Electronic Test and Measurement Instrumentation: Design and Applications (2nd Edition))
  • Review
  • Open Access
38 Citations
10,349 Views
31 Pages

Electromyography Signal Acquisition, Filtering, and Data Analysis for Exoskeleton Development

  • Jung-Hoon Sul,
  • Lasitha Piyathilaka,
  • Diluka Moratuwage,
  • Sanura Dunu Arachchige and ,
  • Amal Jayawardena,
  • Gayan Kahandawa and
  • D. M. G. Preethichandra
  • + 2 authors+ 0 author

27 June 2025

Electromyography (EMG) has emerged as a vital tool in the development of wearable robotic exoskeletons, enabling intuitive and responsive control by capturing neuromuscular signals. This review presents a comprehensive analysis of the EMG signal proc...

(This article belongs to the Special Issue Sensors-Based Healthcare Diagnostics, Monitoring and Medical Devices)
  • Article
  • Open Access
21 Citations
4,760 Views
16 Pages

27 August 2020

Accurate and real-time estimation of force from surface electromyogram (EMG) signals enables a variety of applications. We developed and validated new approaches for selecting subsets of high-density (HD) EMG channels for improved and lower-dimension...

(This article belongs to the Section Biomedical Sensors)
  • Communication
  • Open Access
3 Citations
2,972 Views
11 Pages

This study investigated electromyography (EMG)–force relations using both simulated and experimental approaches. A motor neuron pool model was first implemented to simulate EMG–force signals, focusing on three different conditions that te...

(This article belongs to the Special Issue Recent Advances in the Application of Mathematical and Computational Models in Biomedical Science and Engineering)
  • Article
  • Open Access
3 Citations
4,282 Views
9 Pages

Swallowing Exercise Evaluated Using High-Density Surface Electromyography in Patients with Head and Neck Cancer: Supplementary Analysis of an Exploratory Phase II Trial

  • Kohei Yoshikawa,
  • Takao Hamamoto,
  • Yuki Sato,
  • Kohei Yumii and ,
  • Nobuyuki Chikuie,
  • Takayuki Taruya,
  • Takashi Ishino,
  • Yuichiro Horibe,
  • Kota Takemoto and
  • Sachio Takeno
  • + 10 authors+ 5 authors

4 December 2023

Background and Objectives: Muscle strength evaluation using high-density surface electromyography (HD-sEMG) was recently developed for the detailed analysis of the motor unit (MU). Detection of the spatial distribution of sEMG can detect changes in M...

(This article belongs to the Section Oncology)
  • Article
  • Open Access

UpperMyo: A Six-Muscle Upper-Limb sEMG Dataset with Comparative Machine Learning Evaluations for Action Recognition, Temporal Classification, and Cross-Dataset Transfer

  • Jiaxian Li,
  • Huayue Liu,
  • Xiangyang Li,
  • Zhuofan Li and ,
  • Fan Zhou,
  • Dongdong Gao,
  • Jiang Wu and
  • Huanghe Zhang
  • + 3 authors+ 0 author
Technologies2026, 14(12), 779;https://doi.org/10.3390/technologies14120779 
(registering DOI)

22 November 2026

UpperMyo is an open six-muscle surface electromyography (sEMG) dataset for upper-limb action recognition, sEMG-referenced temporal classification, and cross-dataset transfer. Analyses use 264 recording blocks from 24 healthy male participants, sample...

(This article belongs to the Special Issue Wearable Vital Signs and Activities Detection: Systems and Applications—2nd Edition)
  • Article
  • Open Access
434 Views
32 Pages

Development and Validation of an Automated Pipeline for Motor Unit Analysis from HD-sEMG Signals

  • Maria V. Arteaga,
  • Catalina Alvarado-Rojas,
  • Alain Kaelin-Lang and
  • Daniele Allegri

31 August 2026

High-density surface electromyography (HD-sEMG) enables non-invasive analysis of motor unit (MU) behavior and is crucial in rehabilitation, pathophysiological assessment, and assistive technologies. However, current pipelines still rely on expert int...

(This article belongs to the Section Biomedical Sensors)
  • Article
  • Open Access
2 Citations
3,333 Views
9 Pages

Assessing the Effect of Riluzole on Motor Unit Discharge Properties

  • Ehsan Shandiz,
  • Gabriel Lima Fernandes,
  • Joao Saldanha Henkin,
  • Pamela Ann McCombe and ,
  • Gabriel Siqueira Trajano and
  • Robert David Henderson
  • + 1 author+ 0 author

24 October 2024

Background. This study aims to determine if Riluzole usage can change the function and excitability of motor neurons. Methods. The clinical data and indices of motor neuron excitability were assessed using high-density surface EMG parameters from 80...

(This article belongs to the Special Issue Amyotrophic Lateral Sclerosis: Recent Considerations for Diagnosis, Pathogenesis and Therapy)
  • Article
  • Open Access
13 Citations
3,313 Views
23 Pages

3 June 2025

Upper limb assistive exoskeletons help stroke patients by assisting arm movement in impaired individuals. However, effective control of these systems to help stroke survivors is a complex task. In this paper, a novel approach is proposed to enhance t...

(This article belongs to the Section Biosensors)
  • Perspective
  • Open Access
5 Citations
5,257 Views
11 Pages

15 June 2022

Background: Traumatic spinal cord injury (SCI) is a devastating condition commonly originating from motor vehicle accidents or falls. Trauma care after SCI is challenging; after decompression surgery and spine stabilization, the first step is to asse...

  • Article
  • Open Access
899 Views
13 Pages

Reliability of Between-Session Motor Units Behavior: A Comparison of Analytical Approaches for Intervention Studies

  • Daniel Marcos-Frutos,
  • Kevin Méndez-Bouza,
  • David Colomer-Poveda,
  • Amador García-Ramos and
  • Gonzalo Márquez

17 July 2026

Objective: To compare the between-session reliability of motor units (MUs) behavior derived from high-density surface electromyography (HD-sEMG) during isometric knee extension across three analytical approaches: all identified MUs averaged per parti...

  • Review
  • Open Access
2,895 Views
24 Pages

Electromyographic Analysis of Latissimus Dorsi Activation During Common Resistance Training Exercises: A Narrative Review

  • Domenico Di Fonza,
  • Gloria Di Claudio,
  • Gianmaria Colantuono,
  • Lorenzo Persichini and ,
  • Nicola Cerulo,
  • Benedetta Sangregorio,
  • Andrea Buonsenso,
  • Giovanni Fiorilli,
  • Giuseppe Calcagno and
  • Alessandra di Cagno
  • + 5 authors+ 0 author

Background: The latissimus dorsi (LD) is a primary muscle involved in pulling exercises used in resistance training, contributing to shoulder extension, adduction and internal rotation, with relevance to athletic performance, injury prevention and re...

(This article belongs to the Special Issue Biomechanical and Neuromuscular Perspectives in Resistance Training)
  • Article
  • Open Access
4 Citations
1,912 Views
38 Pages

Hybrid Convolutional Vision Transformer for Robust Low-Channel sEMG Hand Gesture Recognition: A Comparative Study with CNNs

  • Ruthber Rodriguez Serrezuela,
  • Roberto Sagaro Zamora,
  • Daily Milanes Hermosilla,
  • Andres Eduardo Rivera Gomez and
  • Enrique Marañon Reyes

3 December 2025

Hand gesture classification using surface electromyography (sEMG) is fundamental for prosthetic control and human–machine interaction. However, most existing studies focus on high-density recordings or large gesture sets, leaving limited eviden...

(This article belongs to the Special Issue New Biomimetic Advances in Signal and Image Processing for Biomedical Applications 2025)
  • Article
  • Open Access
3 Citations
1,582 Views
19 Pages

Evaluating Stroke-Related Motor Impairment and Recovery Using Macroscopic and Microscopic Features of HD-sEMG

  • Wenting Qin,
  • Xin Tan,
  • Yi Yu,
  • Yujie Zhang and ,
  • Zhanhui Lin,
  • Chenyun Dai,
  • Yuxiang Yang,
  • Lingyu Liu and
  • Lingjing Jin
  • + 4 authors+ 0 author

Stroke-induced motor impairment necessitates objective and quantitative assessment tools for rehabilitation planning. In this study, a gesture-specific framework based on high-density surface electromyography (HD-sEMG) was developed to characterize n...

(This article belongs to the Section Biosignal Processing)
  • Article
  • Open Access
2 Citations
1,908 Views
20 Pages

Denoising Non-Invasive Electroespinography Signals by Different Cardiac Artifact Removal Algorithms

  • Desirée I. Gracia,
  • Eduardo Iáñez,
  • Mario Ortiz and
  • José M. Azorín

29 January 2026

The non-invasive recording of spinal cord neuronal activity, also known as electrospinography (ESG), using high-density surface electromyography (HD-sEMG) is a promising emerging biosensing modality. However, these recordings often contain electrocar...

(This article belongs to the Special Issue Biophysical Sensors for Biomedical/Health Monitoring Applications (2nd Edition))
  • Article
  • Open Access
4 Citations
3,073 Views
15 Pages

Does Muscle Pain Induce Alterations in the Pelvic Floor Motor Unit Activity Properties in Interstitial Cystitis/Bladder Pain Syndrome? A High-Density sEMG-Based Study

  • Monica Albaladejo-Belmonte,
  • Michael Houston,
  • Nicholas Dias,
  • Theresa Spitznagle and ,
  • Henry Lai,
  • Yingchun Zhang and
  • Javier Garcia-Casado
  • + 2 authors+ 0 author

21 November 2024

Several studies have shown interstitial cystitis/bladder pain syndrome (IC/BPS), a chronic condition that poses challenges in both diagnosis and treatment, is associated with painful pelvic floor muscles (PFM) and altered neural drive to these muscle...

(This article belongs to the Section Biomedical Sensors)
  • Article
  • Open Access
726 Views
16 Pages

Spatiotemporal Dual-Channel Interpretable Hybrid Neural Network for HD-sEMG-Based Gesture Recognition

  • Zhefei Cai,
  • Su Liu,
  • Xinyue Li,
  • Michael Houston and ,
  • Yingle Fan and
  • Yingchun Zhang
  • + 1 author+ 0 author

20 July 2026

Accurate gesture recognition is crucial for precision control of upper limb prostheses. High-density surface electromyography (HD-sEMG) enhances spatial resolution and information richness of human gesture representation, thus improving myoelectric c...

(This article belongs to the Special Issue From Brain Signals to Recovery: Neural Sensing for Functional Restoration)
  • Article
  • Open Access
3 Citations
2,315 Views
22 Pages

Early Detection of Dysphagia Signs in Parkinson’s Disease: An Artificial Intelligence-Based Approach Using Non-Invasive Sensors

  • Michele Antonio Gazzanti Pugliese di Cotrone,
  • Nidà Farooq Akhtar,
  • Martina Patera,
  • Silvia Gallo and ,
  • Umberto Mosca,
  • Marco Ghislieri,
  • Claudia Ferraris,
  • Antonio Suppa,
  • Carlo Alberto Artusi and
  • Fernanda Irrera
  • + 12 authors+ 7 authors

8 November 2025

The present study evaluates the effectiveness of a non-invasive wearable sensor system, combining accelerometers, surface electromyography, and artificial intelligence, to objectively characterize swallowing in elderly individuals affected by Parkins...

(This article belongs to the Special Issue Advanced Wearable Sensors and Other Sensing Technologies for Diagnosis and Treatment of Parkinson's Disease and Movement Disorders)
  • Review
  • Open Access
68 Citations
8,645 Views
16 Pages

Central and Peripheral Neuromuscular Adaptations to Ageing

  • Riccardo Borzuola,
  • Arrigo Giombini,
  • Guglielmo Torre,
  • Stefano Campi and ,
  • Erika Albo,
  • Marco Bravi,
  • Paolo Borrione,
  • Chiara Fossati and
  • Andrea Macaluso
  • + 4 authors+ 0 author

Ageing is accompanied by a severe muscle function decline presumably caused by structural and functional adaptations at the central and peripheral level. Although researchers have reported an extensive analysis of the alterations involving muscle int...

(This article belongs to the Special Issue Physical Activity in the Elderly and Orthopaedic Surgery)
  • Article
  • Open Access
2 Citations
2,000 Views
17 Pages

This study investigates age-related differences in motor unit (MU) properties and neuromuscular control during isometric elbow flexion across the human lifespan. High-density surface electromyography (sEMG) was recorded from the biceps brachii of 44...

(This article belongs to the Special Issue Musculoskeletal Function in Health and Disease)
  • Article
  • Open Access
1 Citations
2,301 Views
21 Pages

High-Density Surface Electromyography Excitation of Prime Movers Across Scapular Positions in the Seated Row

  • Riccardo Padovan,
  • Emiliano Cè,
  • Stefano Longo,
  • Gianpaolo Tornatore and ,
  • Fabio Esposito and
  • Giuseppe Coratella
  • + 1 author+ 0 author

Objectives: The present study compared the amplitude and spatial distribution of muscle excitation between a seated row performed with a fixed scapular position (fixed-SR) and a free scapular position (free-SR) in resistance-trained men, analyzing co...

(This article belongs to the Collection Feature Papers in Journal of Functional Morphology and Kinesiology)
  • Article
  • Open Access
5 Citations
4,873 Views
10 Pages

Effect of Acute Static Stretching on the Activation Patterns Using High-Density Surface Electromyography of the Gastrocnemius Muscle during Ramp-Up Task

  • Noriaki Maeda,
  • Makoto Komiya,
  • Yuichi Nishikawa,
  • Masanori Morikawa and ,
  • Shogo Tsutsumi,
  • Tsubasa Tashiro,
  • Kazuki Fukui,
  • Hiroaki Kimura and
  • Yukio Urabe
  • + 4 authors+ 0 author

15 July 2021

This study aimed to evaluate motor unit recruitment during submaximal voluntary ramp contraction in the medial head of the gastrocnemius muscle (MG) by high-density spatial electromyography (SEMG) before and after static stretching (SS) in healthy yo...

(This article belongs to the Section Biosensors)
  • Article
  • Open Access
19 Citations
7,760 Views
14 Pages

Normalised Mutual Information of High-Density Surface Electromyography during Muscle Fatigue

  • Adrian Bingham,
  • Sridhar P. Arjunan,
  • Beth Jelfs and
  • Dinesh K. Kumar

20 December 2017

This study has developed a technique for identifying the presence of muscle fatigue based on the spatial changes of the normalised mutual information (NMI) between multiple high density surface electromyography (HD-sEMG) channels. Muscle fatigue in t...

(This article belongs to the Special Issue Information Theory Applied to Physiological Signals)
  • Article
  • Open Access
1 Citations
1,860 Views
27 Pages

7 January 2026

Control of elbow exoskeletons using muscular signals, although promising for the rehabilitation of millions of patients, has not yet been widely commercialized due to challenges in real-time intention estimation and management of dynamic uncertaintie...

(This article belongs to the Special Issue Recent Trends and Advances in Wearable Exoskeletons, Sensing Technologies and Occupational Ergonomics)
  • Article
  • Open Access
2,204 Views
21 Pages

The Effect of Filtering on Signal Features of Equine sEMG Collected During Overground Locomotion in Basic Gaits

  • Małgorzata Domino,
  • Marta Borowska,
  • Elżbieta Stefanik,
  • Natalia Domańska-Kruppa and ,
  • Michał Skibniewski and
  • Bernard Turek
  • + 1 author+ 0 author

8 May 2025

In equine surface electromyography (sEMG), challenges related to the reliability and interpretability of data arise, among other factors, from methodological differences, including signal processing and analysis. The aim of this study is to demonstra...

(This article belongs to the Special Issue Sensors Technologies for Measurements and Signal Processing)
  • Article
  • Open Access
257 Views
18 Pages

Effects of a 30-Minute Run on Accelerometry-Derived Mechanical Load and Gastrocnemius Surface EMG

  • Gabriel Delgado-García,
  • Berta Benito-Colio and
  • Salvador Boned-Gómez

This study analyzed whether the change in mechanical load during a moderate intensity run, measured with accelerometers, could be explained by neuromuscular fatigue, assessed with surface electromyography (sEMG). Twenty-eight amateur runners complete...

(This article belongs to the Special Issue Electromyography Techniques for Motion Analysis)
  • Article
  • Open Access
10 Citations
4,483 Views
9 Pages

Diabetic neuropathy (DN) is a major complication associated with diabetes mellitus (DM) and results in fatigue. We investigated whether type 2 diabetic patients with or without neuropathy experienced muscle fatigue and determined the most influencing...

(This article belongs to the Special Issue Diabetes in Sports and Exercise Medicine)