Skip to Content

37 Results Found

  • Article
  • Open Access
33 Citations
9,715 Views
12 Pages

A Novel Approach for Partial Discharge Measurements on GIS Using HFCT Sensors

  • Armando Rodrigo Mor,
  • Luis Carlos Castro Heredia and
  • Fabio Andres Muñoz

18 December 2018

This paper presents a novel measuring system for partial discharge (PD) measurements in Gas Insulated Systems (GIS) using high frequency current transformers (HFCT). The system is based on the measurement of the induced PD currents in the GIS enclosu...

(This article belongs to the Special Issue UHF and RF Sensor Technology for Partial Discharge Detection)
  • Article
  • Open Access
8 Citations
3,487 Views
27 Pages

Locating Insulation Defects in HV Substations Using HFCT Sensors and AI Diagnostic Tools

  • Javier Ortego,
  • Fernando Garnacho,
  • Fernando Álvarez,
  • Eduardo Arcones and
  • Abderrahim Khamlichi

16 August 2024

In general, a high voltage (HV) substation can be made up of multiple insulation subsystems: an air insulation subsystem (AIS), gas insulation subsystem (GIS), liquid insulation subsystem (power transformers), and solid insulation subsystem (power ca...

(This article belongs to the Special Issue Sensing Technology for Smart Cities: Data, Analytics, and Visualizations)
  • Article
  • Open Access
223 Citations
28,145 Views
28 Pages

25 March 2015

Partial discharge (PD) measurements provide valuable information for assessing the condition of high voltage (HV) insulation systems, contributing to their quality assurance. Different PD measuring techniques have been developed in the last years spe...

(This article belongs to the Section Physical Sensors)
  • Article
  • Open Access
33 Citations
7,135 Views
16 Pages

29 April 2020

This paper describes a simplified model and a generic model of high-frequency current transformer (HFCT) sensors. By analyzing the models, a universal charge estimation method based on the double time integral of the measured voltage is inferred. The...

(This article belongs to the Special Issue Acoustic, UHF and RF Sensor Technology for Partial Discharge Detection)
  • Article
  • Open Access
12 Citations
3,467 Views
19 Pages

27 June 2023

A synthetic partial discharge (PD) calibrator has been developed to qualify PD analyzers used for insulation diagnosis of HVAC and HVDC grids including cable systems, AIS, GIS, GIL, power transformers, and HVDC converters. PD analyzers that use high-...

(This article belongs to the Section Fault Diagnosis & Sensors)
  • Article
  • Open Access
3 Citations
2,169 Views
20 Pages

This study presents a characterization method for High-Frequency Current Transformers (HFCTs) intended for partial discharge (PD) measurement in on-line acquisition systems designed for AI-based processing and clustering. The primary objective is to...

  • Article
  • Open Access
17 Citations
4,850 Views
14 Pages

The Investigation of Detect Position of Partial Discharge in Cast-Resin Transformer Using High-Frequency Current Transformer Sensor and Acoustic Emission Sensor

  • Nuttee Thungsuk,
  • Narong Mungkung,
  • Apidat Songruk,
  • Khanchai Tunlasakun and ,
  • Kittimasak Tikakosol,
  • Siriwut Nilawat,
  • Kanitphan Boonsomchuae,
  • Toshifumi Yuji,
  • Somchai Arunrungrusmi and
  • Hiroyuki Kinoshita
  • + 5 authors+ 0 author

26 January 2022

The lifetime of a cast-resin transformer mainly depends on the condition of insulation material. Partial discharge (PD) is an important reason for insulation deterioration in cast-resin transformers. Identifying the position of PD is very necessary f...

(This article belongs to the Topic Power Distribution Systems)
  • Article
  • Open Access
4 Citations
5,002 Views
16 Pages

A Comparison of Partial Discharge Sensors for Natural Gas Insulated High Voltage Equipment

  • Phillip Widger,
  • Daniel Carr,
  • Meirion Hills and
  • Alistair Reid

9 August 2020

The research in this paper consists of practical experimentation on a gas insulated section of high voltage equipment filled with carbon dioxide and technical air as a direct replacement to sulphur hexafluoride (SF6) and analyses the results of PD me...

(This article belongs to the Special Issue Acoustic, UHF and RF Sensor Technology for Partial Discharge Detection)
  • Article
  • Open Access
5 Citations
2,232 Views
21 Pages

Novel Reference Method for the Characterization of PD Measuring Systems Using HFCT Sensors

  • Eduardo Arcones,
  • Fernando Álvarez,
  • Javier Ortego and
  • Fernando Garnacho

11 June 2024

During their lifespan, high-voltage (HV) electrical systems are subjected to operating conditions in which electrical, mechanical, thermal and environmental-related stresses occur. These conditions over time lead to unforeseen failures caused by vari...

(This article belongs to the Special Issue Feature Papers in Physical Sensors 2024)
  • Article
  • Open Access
6 Citations
2,276 Views
17 Pages

This study proposes a novel air gap structure to enhance the sensitivity and saturation resistance of high-frequency current transformers (HFCTs) used in partial discharge (PD) detection for high-voltage equipment. While previous research has shown t...

  • Article
  • Open Access
9 Citations
2,934 Views
25 Pages

Scale Modular Test Platform for the Characterization of PD Measuring Systems Using HFCT Sensors

  • Eduardo Arcones,
  • Fernando Álvarez,
  • Abderrahim Khamlichi and
  • Fernando Garnacho

21 February 2024

Today, online partial discharge (PD) measurements are common practice to assess the condition status of dielectrics in high-voltage (HV) electrical grids. However, when online PD measurements are carried out in electrical facilities, several disadvan...

(This article belongs to the Special Issue Feature Papers in Physical Sensors 2023)
  • Article
  • Open Access
1 Citations
1,273 Views
22 Pages

25 April 2026

Knowledge about the condition of electrical equipment in energy networks is of great importance to network operators. Partial discharges are a key parameter for evaluating the health of the insulation. While a quantifiable PD measurement for offline...

(This article belongs to the Special Issue Sensors Technology Applied in Power Systems and Energy Management)
  • Feature Paper
  • Article
  • Open Access
25 Citations
9,214 Views
18 Pages

Separation of Partial Discharge Sources Measured in the High-Frequency Range with HFCT Sensors Using PRPD-teff Patterns

  • Ricardo Albarracín-Sánchez,
  • Fernando Álvarez-Gómez,
  • Carlos A. Vera-Romero and
  • Johnatan M. Rodríguez-Serna

9 January 2020

During the last two decades, on-line partial discharge (PD) measurements have been proven as a very efficient test to evaluate the insulation condition of high-voltage (HV) installations in service. Among the different PD-measuring techniques, the no...

(This article belongs to the Special Issue Data, Signal and Image Processing and Applications in Sensors)
  • Article
  • Open Access
8 Citations
3,392 Views
20 Pages

A Novel Method for Online Diagnostic Analysis of Partial Discharge in Instrument Transformers and Surge Arresters from the Correlation of HFCT and IEC Methods

  • Marcel Antonionni de Andrade Romano,
  • André Melo de Morais,
  • Marcus Vinicius Alves Nunes,
  • Kaynan Maresch and ,
  • Luiz Fernando Freitas-Gutierres,
  • Ghendy Cardoso,
  • Aécio de Lima Oliveira,
  • Erick Finzi Martins,
  • Cristian Hans Correa and
  • Herber Cuadro Fontoura
  • + 5 authors+ 0 author

1 October 2024

In this work, a new methodology is proposed for the online and non-invasive extraction of partial discharge (PD) pulses from raw measurement data obtained using a simplified setup. This method enables the creation of sub-windows with optimized size,...

(This article belongs to the Special Issue Advanced Technologies in Partial Discharge Detection and Fault Diagnosis)
  • Article
  • Open Access
40 Citations
11,147 Views
27 Pages

22 August 2019

Fault arc detection is an important technology to ensure the safe operation of electrical equipment and prevent electrical fires. The high-frequency noise of the arc current is one of the typical arc characteristics of almost all loads. In order to a...

(This article belongs to the Section Physical Sensors)
  • Article
  • Open Access
58 Citations
14,460 Views
37 Pages

24 June 2020

The article presents a novel on-line partial discharge (PD) monitoring system for power transformers, whose functioning is based on the simultaneous use of three unconventional methods of PD detection: high-frequency (HF), ultra-high frequency (UHF),...

(This article belongs to the Special Issue Condition Monitoring and Diagnosis of Electrical Machines)
  • Article
  • Open Access
12 Citations
5,761 Views
13 Pages

High-Frequency Current Transformers Cascade for Power Electronics Measurements

  • Maciej Chojowski,
  • Marcin Baszyński,
  • Robert Sosnowski and
  • Aleksander Dziadecki

4 August 2022

High-frequency current transformers (HFCT) are widely used to measure fast transient current. Their advantages are simple structure and relatively moderate price. Their lower and upper bandwidth are limited, but the HFCT can be easily applied to many...

(This article belongs to the Section Industrial Sensors)
  • Article
  • Open Access
1 Citations
834 Views
17 Pages

30 May 2026

To address the limited spatial localization accuracy of partial discharge (PD) in high-voltage cable terminations and the difficulty in accurately determining the trigger time in traditional ultrasonic detection, this paper proposes an electro-acoust...

(This article belongs to the Special Issue Optical Sensors for Industrial Applications: 2nd Edition)
  • Article
  • Open Access
1 Citations
1,175 Views
36 Pages

Hydrogen fuel cell tractors (HFCTs) represent a critical frontier in the development of modern green agricultural equipment. Due to the heavy-duty and highly variable nature of tractor operations, current fuel cell-powered platforms face significant...

(This article belongs to the Section Energy Supply and Sustainability)
  • Article
  • Open Access
3 Citations
3,692 Views
16 Pages

Precision and Accuracy of Pulse Propagation Velocity Measurement in Power Cables

  • Ivar Kiitam,
  • Muhammad Shafiq,
  • Maninder Choudhary,
  • Martin Parker and ,
  • Ivo Palu and
  • Paul Taklaja
  • + 1 author+ 0 author

14 March 2023

The partial discharge (PD) measurement is an important method used in determining the condition of medium- and high-voltage cable insulation. Considering the propagation velocity of PD signals in power cables is necessary for determining the location...

(This article belongs to the Special Issue Condition Monitoring of Power System Components)
  • Article
  • Open Access
17 Citations
3,910 Views
17 Pages

Maternal Metformin Treatment during Gestation and Lactation Improves Skeletal Muscle Development in Offspring of Rat Dams Fed High-Fat Diet

  • Jiaqi Cui,
  • Lin Song,
  • Rui Wang,
  • Shuyuan Hu and ,
  • Zhao Yang,
  • Zengtie Zhang,
  • Bo Sun and
  • Wei Cui
  • + 3 authors+ 0 author

28 September 2021

Maternal high-fat (HF) diet is associated with offspring metabolic disorder. This study intended to determine whether maternal metformin (MT) administration during gestation and lactation prevents the effect of maternal HF diet on offspring’s skeleta...

(This article belongs to the Section Nutrition in Women)
  • Article
  • Open Access
1 Citations
1,141 Views
25 Pages

27 February 2026

Early detection of fire-related risks in lithium-ion batteries (LIBs) remains a critical challenge, as conventional protection mechanisms typically activate only after irreversible degradation or macroscopic failure occurs. In this study, an innovati...

(This article belongs to the Section Electronic Sensors)
  • Article
  • Open Access
14 Citations
6,470 Views
15 Pages

A Novel Method for PD Feature Extraction of Power Cable with Renyi Entropy

  • Jikai Chen,
  • Yanhui Dou,
  • Zhenhao Wang and
  • Guoqing Li

13 November 2015

Partial discharge (PD) detection can effectively achieve the status maintenance of XLPE (Cross Linked Polyethylene) cable, so it is the direction of the development of equipment maintenance in power systems. At present, a main method of PD detection...

(This article belongs to the Special Issue Wavelets, Fractals and Information Theory I)
  • Article
  • Open Access
6 Citations
2,584 Views
17 Pages

Metrological Qualification of PD Analysers for Insulation Diagnosis of HVDC and HVAC Grids

  • Fernando Garnacho,
  • Fernando Álvarez,
  • Alf-Peter Elg,
  • Christian Mier and ,
  • Kari Lahti,
  • Abderrahim Khamlichi,
  • Eduardo Arcones,
  • Joni Klüss,
  • Armando Rodrigo Mor and
  • Miran Haider
  • + 10 authors+ 5 authors

11 July 2023

On-site partial discharge (PD) measurements have turned out to be a very efficient technique for determining the insulation condition in high-voltage electrical grids (AIS, cable systems, GIS, HVDC converters, etc.); however, there is not any standar...

(This article belongs to the Section Electronic Sensors)
  • Article
  • Open Access
26 Citations
5,807 Views
10 Pages

Wideband UHF Antenna for Partial Discharge Detection

  • Zhen Cui,
  • Seungyong Park,
  • Hosung Choo and
  • Kyung-Young Jung

2 March 2020

This paper presents a ultra-high frequency (UHF) antenna for partial discharge (PD) detection and the antenna sensor can be used near a conducting ground wire. The proposed UHF antenna has advantages of easy setup and higher-frequency detection over...

(This article belongs to the Collection Electromagnetic Antennas for HF, VHF, and UHF Band Applications)
  • Article
  • Open Access
24 Citations
9,256 Views
13 Pages

Partial Discharge Analysis in High-Frequency Transformer Based on High-Frequency Current Transducer

  • Jun Jiang,
  • Mingxin Zhao,
  • Chaohai Zhang,
  • Min Chen and ,
  • Haojun Liu and
  • Ricardo Albarracín
  • + 1 author+ 0 author

1 August 2018

High-frequency transformers are the core components of power electronic transformers (PET), whose insulation is deeply threatened by high voltage (HV) and high frequency (HF). The partial discharge (PD) test is an effective method to assess an electr...

(This article belongs to the Section F: Electrical Engineering)
  • Article
  • Open Access
60 Citations
9,829 Views
14 Pages

Towards Optical Partial Discharge Detection with Micro Silicon Photomultipliers

  • Ming Ren,
  • Jierui Zhou,
  • Bo Song,
  • Chongxing Zhang and ,
  • Ming Dong and
  • Ricardo Albarracín
  • + 1 author+ 0 author

10 November 2017

Optical detection is reliable in intrinsically characterizing partial discharges (PDs). Because of the great volume and high-level power supply of the optical devices that can satisfy the requirements in photosensitivity, optical PD detection can mer...

(This article belongs to the Section Physical Sensors)
  • Article
  • Open Access
25 Citations
4,618 Views
16 Pages

Hybrid Sensing of Internal and Surface Partial Discharges in Air-Insulated Medium Voltage Switchgear

  • Ghulam Amjad Hussain,
  • Ashraf A. Zaher,
  • Detlef Hummes,
  • Madia Safdar and
  • Matti Lehtonen

5 April 2020

Partial discharge (PD) measurements have proved their reliability for health monitoring of insulation systems in power system components including synchronous generators, power transformers, switchgear and cables etc. Online condition monitoring and...

(This article belongs to the Special Issue Selected Papers from the 19th IEEE International Conference on Environment and Electrical Engineering (19th IEEE EEEIC))
  • Article
  • Open Access
1,959 Views
21 Pages

Use of Oil Shale as a Catalyst and Hydrogen Donor in the Processing of Heavy Hydrocarbons: Accumulation of Rare Trace Elements and Production of Light Fractions

  • Murzabek Baikenov,
  • Dariya Izbastenova,
  • Xintai Su,
  • Akmaral Sarsenbekova and ,
  • Alfiya Khalitova,
  • Almas Tusipkhan,
  • Amirbek Moldabayev,
  • Balzhan Tulebaeva,
  • Gulzhan Baikenova and
  • Satybaldin Amangeldy
  • + 5 authors+ 0 author

This study presents an integrated approach to processing the heavy fraction of coal tar (HFCT) using oil shale (OS) from Shubarkol Komir JSC to simultaneously increase the yield of valuable hydrocarbon fractions and extract rare and dispersed trace e...

  • Article
  • Open Access
352 Views
26 Pages

Energy Mix Optimization for Yard Trucks in Container Ports Under Low-Carbon Constraints

  • Linlin Zhang,
  • Junhao Lai,
  • Ke Hu,
  • Ye Zhang and ,
  • Qinmei Zhu,
  • Pengjun Zheng and
  • Guiyun Liu
  • + 2 authors+ 0 author

13 August 2026

With the rapid expansion of global trade, the environmental impacts of port operations have attracted increasing attention. This study develops a mixed-integer programming (MIP) model to identify low-carbon energy mix replacement pathways for yard tr...

  • Article
  • Open Access
703 Views
25 Pages

2 September 2026

Reliable partial discharge (PD) assessment of air-insulated medium voltage (MV) metal-clad switchgear is challenged by the close proximity of adjacent units and the noise environment generated by control, relay, and mechanical or electromechanical eq...

(This article belongs to the Special Issue Advanced Sensing Applications in Non-Destructive Testing and Electromagnetic Compatibility)
  • Article
  • Open Access
3 Citations
2,018 Views
25 Pages

Embedded System for Monitoring Fuel Cell Power Supply System in Mobile Applications

  • Miroslav Matejček,
  • Mikuláš Šostronek,
  • Eva Popardovská,
  • Vladimír Popardovský and
  • Marián Babjak

This study deals with a fuel-cell-based power supply system created from a fuel cell stack with a proton exchange membrane fuel cell (PEMFC) and controller monitoring system (Horizon Fuell Cell Technologies (HFCT)). In the fuel cell (FC) stack H60, t...

(This article belongs to the Special Issue New Advances in Embedded Software and Applications)
  • Article
  • Open Access
2 Citations
1,018 Views
21 Pages

GIS Partial Discharge Fault Diagnosis Based on Multi-Source Feature Fusion and ResNet-MLP

  • Bingjian Jia,
  • Qing Sun,
  • Weiwei Guo,
  • Mingzheng Wang and ,
  • Qian Wang and
  • Hongfeng Zhao
  • + 1 author+ 0 author

19 February 2026

Partial discharge (PD) signals in gas-insulated switchgear (GIS) exhibit complex characteristics, and single-modal feature recognition methods face limitations in achieving satisfactory diagnostic accuracy due to incomplete fault information represen...

(This article belongs to the Special Issue Advanced Dielectric Materials, Sensing, Monitoring, and Diagnostic Technologies for High-Voltage Equipment in New Power Systems)
  • Article
  • Open Access
1 Citations
1,436 Views
23 Pages

Tip Discharge Evolution Characteristics and Mechanism Analysis via Optical–Electrical Sensors in Oil-Immersed Transformers

  • Zehao Chen,
  • Yong Qian,
  • Gehao Sheng,
  • Fenghua Wang and ,
  • Bing Xue,
  • Chunhui Zhang and
  • Chengxiang Liu
  • + 2 authors+ 0 author

4 January 2026

Tip discharge in oil-immersed transformers poses a significant threat to insulation integrity. Conventional detection methods, such as gas and electrical analysis, are limited by slow response times or susceptibility to interference. Additionally, th...

(This article belongs to the Section Optical Sensors)
  • Article
  • Open Access
1 Citations
803 Views
33 Pages

Decarbonizing heavy-duty road transport requires comparing zero-emission options to guide infrastructure investments along strategic corridors. This study develops a scenario-based techno-economic model to evaluate hydrogen fuel cell trucks (HFCTs) a...

  • Article
  • Open Access
14 Citations
5,994 Views
14 Pages

PCB-Based Planar Inductive Loops for Partial Discharges Detection in Power Cables

  • Sinda Kaziz,
  • Pietro Romano,
  • Antonino Imburgia,
  • Guido Ala and ,
  • Halim Sghaier,
  • Denis Flandre and
  • Fares Tounsi
  • + 2 authors+ 0 author

27 December 2022

Partial discharge (PD) diagnosis tests, including detecting, locating, and identifying, are used to trace defects or faults and assess the degree of aging in order to monitor the insulation condition of medium- and high-voltage power cables. In this...

(This article belongs to the Special Issue Advanced Sensing and Evaluating Technology in Nondestructive Testing)
  • Article
  • Open Access
6 Citations
4,278 Views
24 Pages

Validation of a Qualification Procedure Applied to the Verification of Partial Discharge Analysers Used for HVDC or HVAC Networks

  • Carlos Vera,
  • Fernando Garnacho,
  • Joni Klüss,
  • Christian Mier and ,
  • Fernando Álvarez,
  • Kari Lahti,
  • Abderrahim Khamlichi,
  • Alf-Peter Elg,
  • Armando Rodrigo Mor and
  • Antonio Squicciarini
  • + 13 authors+ 8 authors

14 July 2023

The insulation condition of HVDC grids consisting of cable systems, GIS, and converters should be monitored by partial discharge (PD) analysers using artificial intelligence (AI) tools for efficient insulation diagnosis. Although there are many exper...

(This article belongs to the Special Issue Grounding Systems Optimization for Low-Frequency Fault Currents and Lightning Strikes)