Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (28)

Search Parameters:
Keywords = body-worn electronics

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
30 pages, 5350 KB  
Article
Application of TRIZ Methodological Tools for Wearable Device Design Using Low-Cost Off-the-Shelf Sensors
by Efrain Atenogenes Mejía-González, Miguel Angel Castro-Perez, Salvador Villarreal-Reyes, Jesús Everardo Olguín-Tiznado, Alejandro Galaviz-Mosqueda, Claudia Camargo-Wilson, Julio César Cano-Gutiérrez, Jorge Luis García-Alcaraz and Cecilia Rodríguez-Serrato
Appl. Sci. 2026, 16(11), 5270; https://doi.org/10.3390/app16115270 - 25 May 2026
Viewed by 567
Abstract
Currently, there is a widespread use of inertial motion units (IMUs) based on micromechanical systems (MEMS) with applications ranging from consumer electronics to medical devices. One of the main uses of this technology is in human body motion capture systems, which require attaching [...] Read more.
Currently, there is a widespread use of inertial motion units (IMUs) based on micromechanical systems (MEMS) with applications ranging from consumer electronics to medical devices. One of the main uses of this technology is in human body motion capture systems, which require attaching various IMUs to the body. It is customary to start the design of IMU-based motion capture solutions by using generic off-the-shelf (OTS) solutions or custom integrations. However, it is common that generic OTS solutions or custom IMUs integrations are not necessarily intended or designed to be directly attached to the human body. To address this issue, a widely adopted solution is to perform quick workarounds to enable the IMUs to be “worn” by prospective users. However, this can have the drawbacks of increased probability of detachment, improper fit, user discomfort, adding noise to the IMU measurements, etc. Therefore, the development of OTS IMU-based motion capture solutions would greatly benefit from having a methodological approach for the design of device housings and/or adaptations for OTS solutions or custom IMU integrations, such that they can be effectively used as wearable devices. In this work, we introduce a design methodology for wearable devices based on the Theory of Inventive Problem Solving (TRIZ). By designing a “wearable device housing” for an OTS IMU solution, we show that the proposed TRIZ-based methodology provides a straightforward and structured approach for the design of wearable devices. Furthermore, we illustrate how various challenges encountered in the early stages of prototype development can be effectively addressed using this methodology. The results obtained with the study case confirm that the proposed TRIZ-based methodology effectively overcomes the challenges associated with the design of wearable devices based on generic OTS solutions or custom IMU integrations. Full article
(This article belongs to the Special Issue Wearable Devices: Design and Performance Evaluation)
Show Figures

Figure 1

17 pages, 3923 KB  
Article
The Parametrization of Electromagnetic Emissions and Hazards from a Wearable Device for Wireless Information Transfer with a 2.45 GHz ISM Band Antenna
by Patryk Zradziński, Jolanta Karpowicz and Krzysztof Gryz
Appl. Sci. 2025, 15(12), 6602; https://doi.org/10.3390/app15126602 - 12 Jun 2025
Cited by 1 | Viewed by 1509
Abstract
The parameters of electromagnetic emissions from the antenna of a wearable radio communication module (parameterizing device functionality) were investigated at different positions near the body where an antenna is located. The specific absorption rate (SAR) coefficient was also investigated as a way of [...] Read more.
The parameters of electromagnetic emissions from the antenna of a wearable radio communication module (parameterizing device functionality) were investigated at different positions near the body where an antenna is located. The specific absorption rate (SAR) coefficient was also investigated as a way of parameterizing the absorption of electromagnetic radiation in the user’s body adjacent to the antenna in various locations. The modeled exposure scenarios concerned a body-worn device with a 2.45 GHz ISM band antenna (used, e.g., for Wi-Fi 2G/Bluetooth applications). The antennas were modeled as follows: (1) located directly on the body (considered to be a model of a disposable, adhesive device) or (2) next to the body (considered to be a model of a classic, reusable, wearable electronic device located inside a plastic housing). Several body sections adjacent to the antenna were considered: head, arm, forearm, and chest (simplified and anatomical body models were used). The numerical models of the exposure scenarios were verified by relevant laboratory tests using physical models. It was found that the use of simplified models of the human body (numerical or physical) may be sufficient when analyzing antenna performance and SAR in a user’s body, such as in studies regarding microwave imaging and sensing, wireless implantable devices, wireless body-area networks or SAR estimation. Full article
(This article belongs to the Special Issue Antennas for Next-Generation Electromagnetic Applications)
Show Figures

Figure 1

25 pages, 3952 KB  
Review
Wearable Medical Devices: Application Status and Prospects
by Xiaowen Wang, Yingnan Gao, Yueze Yuan, Yaping Wang, Anqin Liu, Sen Jia and Wenguang Yang
Micromachines 2025, 16(4), 394; https://doi.org/10.3390/mi16040394 - 28 Mar 2025
Cited by 4 | Viewed by 3263
Abstract
Electronic skin (E-skin) refers to a portable medical or health electronic device that can be worn directly on the human body and can carry out perception, recording, analysis, regulation, intervention and even treatment of diseases or maintenance of health status through software support. [...] Read more.
Electronic skin (E-skin) refers to a portable medical or health electronic device that can be worn directly on the human body and can carry out perception, recording, analysis, regulation, intervention and even treatment of diseases or maintenance of health status through software support. Its main features include wearability, real-time monitoring, convenience, etc. E-skin is convenient for users to wear for a long time and continuously monitors the user’s physiological health data (such as heart rate, blood pressure, blood glucose, etc.) in real time. Health monitoring can be performed anytime and anywhere without frequent visits to hospitals or clinics. E-skin integrates multiple sensors and intelligent algorithms to automatically analyze data and provide health advice and early warning. It has broad application prospects in the medical field. With the increasing demand for E-skin, the development of multifunctional integrated E-skin with low power consumption and even autonomous energy has become a common goal of many researchers. This paper outlines the latest progress in the application of E-skin in physiological monitoring, disease treatment, human–computer interaction and other fields. The existing problems and development prospects in this field are presented. Full article
(This article belongs to the Special Issue Flexible and Wearable Sensors, 3rd Edition)
Show Figures

Figure 1

14 pages, 1317 KB  
Review
Advances and Classification of Autonomous Systems in Biomedical Devices: Integration of Energy Harvesting and Ultra-Low Power Consumption
by José Alejandro Amezquita Garcia, Miguel E. Bravo Zanoguera and Fabian N. Murrieta-Rico
Electronics 2025, 14(1), 144; https://doi.org/10.3390/electronics14010144 - 1 Jan 2025
Cited by 7 | Viewed by 2872
Abstract
Autonomous electronic systems are becoming increasingly important in people’s lives, as a result of advances in efficient energy storage systems, devices that can be permanently implanted in humans, and the trend towards compact devices that function as an extension of the human body. [...] Read more.
Autonomous electronic systems are becoming increasingly important in people’s lives, as a result of advances in efficient energy storage systems, devices that can be permanently implanted in humans, and the trend towards compact devices that function as an extension of the human body. In addition, strategies continue to be found for the integration of energy harvesting in a constant and efficient manner. Covering the numerous advances made in biomedical devices can be quite overwhelming. This work presents a review of the latest strategies developed to produce energy from human body activity, the energy collectors for devices, and the strategies to create ultra-low-power wearable devices. The review focuses on the potential energy sufficiency required to power devices that can be implanted or worn, while also providing information about the patient’s condition. A comparison between the energies produced by different instruments and the improvements in the development of low-consumption devices is presented, with a focus on the type of medical devices. A new approach is established to classify and locate the most recent advances in autonomous systems in biomedicine based on their complexity/function. Full article
Show Figures

Figure 1

13 pages, 3626 KB  
Article
Discovering Halite Traces on a Victim’s Clothing through a Forensic Geoscience Analytical Approach: A Suspicious Case in Italy
by Marcelo da Silveira Tortolero Araujo Lourenço, Rosa Maria Di Maggio, Chiara Germinario, Celestino Grifa, Francesco Izzo, Alessio Langella and Mariano Mercurio
Forensic Sci. 2024, 4(3), 396-408; https://doi.org/10.3390/forensicsci4030024 - 5 Aug 2024
Cited by 1 | Viewed by 3370
Abstract
This suspect case focuses on investigating the presence of halite (NaCl) crystals on the clothing of a deceased individual to determine whether they resulted from immersion in seawater or residual absorption after immersion (i.e., the crystals were left on the clothing after contact [...] Read more.
This suspect case focuses on investigating the presence of halite (NaCl) crystals on the clothing of a deceased individual to determine whether they resulted from immersion in seawater or residual absorption after immersion (i.e., the crystals were left on the clothing after contact with the victim’s wet body). Thirteen clothing samples were collected from various garments worn by the victim and were subjected to optical stereomicroscopy, Scanning Electron Microscopy (SEM), coupled with Energy Dispersive Spectroscopy (EDS), and Simultaneous Thermal Analysis (STA). Optical stereomicroscopy revealed numerous white-colored, vitreous, and greasy luster microcrystals dispersed between fabric fibers, with higher concentrations observed near the hem seams and metal rivets. These microcrystals exhibited predominantly cubic and irregular morphologies. Additionally, sandy particles and organic elements, such as plant fragments and micro seashells, were detected, indicative of coastal environment exposure. SEM-EDS analysis confirmed the presence mainly of sodium and chlorine in stoichiometric ratios consistent with halite, with crystals exhibiting amorphous, needle-shaped, or cubic morphologies. Furthermore, STA analysis identified weight loss events attributed to organic decomposition and halite decomposition at high temperatures, corroborating SEM-EDS findings. The distribution and characteristics of halite crystals, along with other trace elements, support the hypothesis of immersion in seawater while wearing clothing. Specifically, the higher concentrations of halite crystals near thicker fabric portions and metal rivets suggest slower drying rates and longer evaporation times, indicative of immersion rather than residual absorption after swimming. This finding not only helps in determining the victim’s exposure to seawater but also establishes a methodology for distinguishing between different sources of halite residue on clothing. Overall, the comprehensive mineralogical characterization of halite crystals on clothing samples, using best practices of forensic mineralogy, provides valuable forensic insights related to the circumstances that led to the victim’s death. This approach aided investigators in reconstructing the sequence of events, enhancing the accuracy of forensic reconstructions. Moreover, this study contributes to the broader field of forensic geoscience by demonstrating the practical applications of mineralogical analysis in criminal investigations, potentially guiding future research and improving investigative techniques in similar cases. Full article
(This article belongs to the Special Issue The Role of Forensic Geology in Criminal Investigations)
Show Figures

Figure 1

15 pages, 18492 KB  
Article
Mechanical Properties and Wear Resistance of Biodegradable ZnMgY Alloy
by Nicanor Cimpoesu, Viorel Paleu, Catalin Panaghie, Ana-Maria Roman, Alin Marian Cazac, Lucian-Ionel Cioca, Costica Bejinariu, Stefan Constantin Lupescu, Mihai Axinte, Mihai Popa and Georgeta Zegan
Metals 2024, 14(7), 836; https://doi.org/10.3390/met14070836 - 22 Jul 2024
Cited by 7 | Viewed by 2637
Abstract
Biodegradable metallic materials are gaining attention for medical applications in short-term implants (15–500 days) because of their good mechanical properties, biocompatibility, and generalized corrosion. Most medical applications involve implant wear processes, particularly for bone fractures. Parallelepipedic specimens (dimensions 50 mm × 10 mm [...] Read more.
Biodegradable metallic materials are gaining attention for medical applications in short-term implants (15–500 days) because of their good mechanical properties, biocompatibility, and generalized corrosion. Most medical applications involve implant wear processes, particularly for bone fractures. Parallelepipedic specimens (dimensions 50 mm × 10 mm × 3 mm) were obtained by cutting the hot-rolled material processed from cast ingots of ZnMgY. To test the tribological performance of these stationary specimens, they were placed at the upper point of the machine’s tribological contact. The rotating lower disk of the AMSLER machine (AMSLER & Co., Schaffhouse, Switzerland) is manufactured from AISI 52100 bearing steel with a 62–65 HRC hardness and a diameter of 59 mm both radially and axially. Frictional torque is the parameter that is measured. Scanning Electron Microscopy (SEM) and Energy Dispersive Spectroscopy (EDS) were used to analyze the worn areas. The material behavior in the normal and wear states upon immersion in simulated body fluid (SBF) was evaluated. Full article
(This article belongs to the Section Biobased and Biodegradable Metals)
Show Figures

Figure 1

18 pages, 4563 KB  
Article
Design Considerations and Experimental Testing of a Wide-Area Inductive Power Transfer (IPT) System for Body-Worn Electronics
by Steve Burrow, Lindsay Clare, Bernard Stark, Steve Beeby and Neil Grabham
Energies 2024, 17(14), 3367; https://doi.org/10.3390/en17143367 - 9 Jul 2024
Viewed by 1795
Abstract
The provision of wireless and battery-free power is key to extending the applications of body-worn sensing electronics. This paper investigates the design of an IPT system for a body-worn scenario where the challenges include highly variable coupling, the requirement for the coil/s to [...] Read more.
The provision of wireless and battery-free power is key to extending the applications of body-worn sensing electronics. This paper investigates the design of an IPT system for a body-worn scenario where the challenges include highly variable coupling, the requirement for the coil/s to be flexible, and close proximity to the body. Variable coupling results in a system that must operate with received powers ranging over orders of magnitude, whilst the use of flexible coils reduces the Q-factor and results in the potential for inductance variation. The human exposure considerations limit both the maximum field strengths that the wearer of a receiver coil might experience and the field strengths that a third party might be exposed to. In this paper, analytical models are used to identify key design variables and to guide the design synthesis of an IPT system for a wrist-worn medical sensor. Practical circuits to drive the transmit coil and to interface the receive coil with the load electronics are described. A prototype system is tested to validate the theoretical analysis, providing power greater than 2 mW to the sensor over a hemispherical region up to 250 mm in radius from the transmit coil. Full article
(This article belongs to the Section F3: Power Electronics)
Show Figures

Figure 1

12 pages, 836 KB  
Article
Can Wrist-Worn Medical Devices Correctly Identify Ovulation?
by Angela Niggli, Martina Rothenbühler, Maike Sachs and Brigitte Leeners
Sensors 2023, 23(24), 9730; https://doi.org/10.3390/s23249730 - 9 Dec 2023
Cited by 8 | Viewed by 5956
Abstract
(1) Background: Hormonal fluctuations across the menstrual cycle lead to multiple changes in physiological parameters such as body temperature, cardiovascular function, respiratory rate and perfusion. Electronic wearables analyzing those parameters might present a convenient alternative to urinary ovulation tests for predicting the fertile [...] Read more.
(1) Background: Hormonal fluctuations across the menstrual cycle lead to multiple changes in physiological parameters such as body temperature, cardiovascular function, respiratory rate and perfusion. Electronic wearables analyzing those parameters might present a convenient alternative to urinary ovulation tests for predicting the fertile window. (2) Methods: We conducted a prospective observational study including women aged 18–45 years without current hormonal therapy who used a wrist-worn medical device and urinary ovulation tests for a minimum of three cycles. We analyzed the accuracy of both the retrospective and prospective algorithms using a generalized linear mixed-effects model. The findings were compared to real-world data from bracelet users who also reported urinary ovulation tests. (3) Results: A total of 61 study participants contributing 205 cycles and 6081 real-life cycles from 3268 bracelet users were included in the analysis. The mean error in identifying ovulation with the wrist-worn medical device retrospective algorithm in the clinical study was 0.31 days (95% CI −0.13 to 0.75). The retrospective algorithm identified 75.4% of fertile days, and the prospective algorithm identified 73.8% of fertile days correctly within the pre-specified equivalence limits (±2 days). The quality of the retrospective algorithm in the clinical study could be confirmed by real-world data. (4) Conclusion: Our data indicate that wearable sensors may be used to accurately detect the periovulatory period. Full article
(This article belongs to the Special Issue Wearable Sensors for Monitoring Athletic and Clinical Cohorts)
Show Figures

Figure 1

12 pages, 5397 KB  
Article
Investigation of the Effect of Additional Zirconium Diboride (ZrB2) in Spherical Graphite Cast Iron on Mechanical Properties
by Rifat Yakut and Ramazan Ortakaya
Coatings 2023, 13(8), 1385; https://doi.org/10.3390/coatings13081385 - 7 Aug 2023
Cited by 5 | Viewed by 1842
Abstract
Steering gearbox bodies, which are produced from spheroidal graphite cast iron, experience wear and gaps over time since they operate under load. It is important to strengthen steering gearbox bodies to avoid this. In this study, a steering gearbox body was produced from [...] Read more.
Steering gearbox bodies, which are produced from spheroidal graphite cast iron, experience wear and gaps over time since they operate under load. It is important to strengthen steering gearbox bodies to avoid this. In this study, a steering gearbox body was produced from a spheroidal graphite cast iron material with zirconium diboride at varying rates (0%, 0.227%, 0.455%, and 1.364%). Samples of the material were prepared according to established standards for hardness, compressive strength, and wear resistance tests. The mechanical properties of test samples with and without zirconium diboride (hardness, compressive strength, and wear resistance) were compared. Sample C showed the highest hardness measurement of 243 HB after adding 0.455% zirconium diboride. As the rate of addition increased, the values obtained from the hardness measurement test also increased. Sample C had the highest compressive value of 1438 MPa, with a 0.455% addition rate. It was found that the compressive strength values also increased as the addition rate increased. Wear tests were conducted to analyse wear volume, wear rate, and friction coefficients. A scanning electron microscope (SEM) device was utilised to identify wear mechanisms on the worn surfaces of the samples. Per the results of this study, wear volume values were found to increase with the load value. Full article
(This article belongs to the Special Issue Tribological Properties and Wear Protection of Coatings and Alloys)
Show Figures

Figure 1

14 pages, 7867 KB  
Article
Inductive Coupling of Bipolar Signals with a Conjugate Coil Pair for an Analog Passive ECG Sensor Using a PPy-Coated pvCNT Dry Electrodes
by Mohammad Abu-Saude and Bashir I. Morshed
Sensors 2023, 23(11), 5283; https://doi.org/10.3390/s23115283 - 2 Jun 2023
Cited by 6 | Viewed by 2783
Abstract
The wireless capture of analog differential signals from fully passive (battery-less) sensors is technically challenging but it can allow for the seamless capture of differential biosignals such as an electrocardiogram (ECG). This paper presents a novel design for the wireless capture of analog [...] Read more.
The wireless capture of analog differential signals from fully passive (battery-less) sensors is technically challenging but it can allow for the seamless capture of differential biosignals such as an electrocardiogram (ECG). This paper presents a novel design for the wireless capture of analog differential signals using a novel conjugate coil pair for a wireless resistive analog passive (WRAP) ECG sensor. Furthermore, we integrate this sensor with a new type of dry electrode, namely conductive polymer polypyrrole (PPy)-coated patterned vertical carbon nanotube (pvCNT) electrodes. The proposed circuit uses dual-gate depletion-mode MOSFETs to convert the differential biopotential signals to correlated drain-source resistance changes and the conjugate coil wirelessly transmits the differences of the two input signals. The circuit rejects (17.24 dB) common mode signals and passing only differential signals. We have integrated this novel design with our previously reported PPy-coated pvCNT dry ECG electrodes, fabricated on a stainless steel substrate with a diameter of 10 mm, which provided a zero-power (battery-less) ECG capture system for long duration monitoring. The scanner transmits an RF carrier signal at 8.37 MHz. The proposed ECG WRAP sensor uses only two complementary biopotential amplifier circuits, each of which has a single-depletion MOSFET. The amplitude-modulated RF signal is envelope-detected, filtered, amplified, and transmitted to a computer for signal processing. ECG signals are collected using this WRAP sensor and compared with a commercial counterpart. Due to the battery-less nature of the ECG WRAP sensor, it has the potential to be a body-worn electronic circuit patch with dry pvCNT electrodes that stably operate for a long period of time. Full article
(This article belongs to the Special Issue Wearable Sensors for Physical Activity and Healthcare Monitoring)
Show Figures

Figure 1

18 pages, 4018 KB  
Article
A Probabilistic Model of Human Activity Recognition with Loose Clothing
by Tianchen Shen, Irene Di Giulio and Matthew Howard
Sensors 2023, 23(10), 4669; https://doi.org/10.3390/s23104669 - 11 May 2023
Cited by 5 | Viewed by 2730
Abstract
Human activity recognition has become an attractive research area with the development of on-body wearable sensing technology. Textiles-based sensors have recently been used for activity recognition. With the latest electronic textile technology, sensors can be incorporated into garments so that users can enjoy [...] Read more.
Human activity recognition has become an attractive research area with the development of on-body wearable sensing technology. Textiles-based sensors have recently been used for activity recognition. With the latest electronic textile technology, sensors can be incorporated into garments so that users can enjoy long-term human motion recording worn comfortably. However, recent empirical findings suggest, surprisingly, that clothing-attached sensors can actually achieve higher activity recognition accuracy than rigid-attached sensors, particularly when predicting from short time windows. This work presents a probabilistic model that explains improved responsiveness and accuracy with fabric sensing from the increased statistical distance between movements recorded. The accuracy of the comfortable fabric-attached sensor can be increased by 67% more than rigid-attached sensors when the window size is 0.5s. Simulated and real human motion capture experiments with several participants confirm the model’s predictions, demonstrating that this counterintuitive effect is accurately captured. Full article
(This article belongs to the Special Issue Biosignal Sensing Analysis (EEG, MEG, ECG, PPG))
Show Figures

Figure 1

21 pages, 9956 KB  
Review
Recent Advances in Nanomaterials Used for Wearable Electronics
by Minye Yang, Zhilu Ye, Yichong Ren, Mohamed Farhat and Pai-Yen Chen
Micromachines 2023, 14(3), 603; https://doi.org/10.3390/mi14030603 - 5 Mar 2023
Cited by 27 | Viewed by 9273
Abstract
In recent decades, thriving Internet of Things (IoT) technology has had a profound impact on people’s lifestyles through extensive information interaction between humans and intelligent devices. One promising application of IoT is the continuous, real-time monitoring and analysis of body or environmental information [...] Read more.
In recent decades, thriving Internet of Things (IoT) technology has had a profound impact on people’s lifestyles through extensive information interaction between humans and intelligent devices. One promising application of IoT is the continuous, real-time monitoring and analysis of body or environmental information by devices worn on or implanted inside the body. This research area, commonly referred to as wearable electronics or wearables, represents a new and rapidly expanding interdisciplinary field. Wearable electronics are devices with specific electronic functions that must be flexible and stretchable. Various novel materials have been proposed in recent years to meet the technical challenges posed by this field, which exhibit significant potential for use in different wearable applications. This article reviews recent progress in the development of emerging nanomaterial-based wearable electronics, with a specific focus on their flexible substrates, conductors, and transducers. Additionally, we discuss the current state-of-the-art applications of nanomaterial-based wearable electronics and provide an outlook on future research directions in this field. Full article
(This article belongs to the Special Issue Novel Materials and Their Sensing Applications)
Show Figures

Figure 1

18 pages, 7947 KB  
Article
Flexible and Robust Triboelectric Nanogenerators with Chemically Prepared Metal Electrodes and a Plastic Contact Interface Based on Low-Cost Pressure-Sensitive Adhesive
by Shuai-Chen Wang, Binbin Zhang, Lijing Kang, Cunman Liang, Dongdong Chen, Guoqiang Liu and Xuyun Guo
Sensors 2023, 23(4), 2021; https://doi.org/10.3390/s23042021 - 10 Feb 2023
Cited by 9 | Viewed by 5578
Abstract
Triboelectric nanogenerators (TENGs) are devices that can harvest energy from mechanical motions; such devices can be used to power wearable sensors and various low-power electronics. To increase the lifetime of the device, scientists mainly use the method of making TENG in a hard [...] Read more.
Triboelectric nanogenerators (TENGs) are devices that can harvest energy from mechanical motions; such devices can be used to power wearable sensors and various low-power electronics. To increase the lifetime of the device, scientists mainly use the method of making TENG in a hard skeleton to simplify the complex possible relative movements between two triboelectric parts. However, the hard skeletons cannot be embedded in soft and lightweight clothing. To make matters worse, the materials used in the garments must be able to withstand high mechanical forces when worn, such as the pressure of more than 100 KPa exerted by body pressure or everyday knocks. Notably, the TENGs are usually made of fragile materials, such as vacuum-evaporated metal electrodes and nano-sized coatings, on the contact interface; these electrodes and coatings often chip or wear off under the action of external loads. In this work, we succeeded in creating a thin, light-weight, but extremely robust garment-integrated triboelectric nanogenerator (G-TENG) that can be embedded in clothing and pass the water wash test. First, we chemically deposited a durable electrode with flexible properties for G-TENG using a novel technique called polymer-assisted metal deposition (PAMD). The as-formed metal electrodes are firmly bonded to the plastic substrate by a sub-10 nm adhesive polymer brush and can withstand a pressure of 22.5 MPa and a tear force of 0.7 MPa. We then removed the traditionally used fragile nanoparticle materials and the non-durable poly-dimethylsiloxane (PDMS) layer at the triboelectric interface, and then used a cost-effective, durable and slightly flowable pressure-sensitive adhesive to form a plastic contact interface. Such a soft plastic interface can ensure full contact of the triboelectric materials, which is excellent in complex environments and ultimately improves the power generation efficiency of the devices. The as-formed low-cost energy harvesting device could become an industry standard for future smart clothing. Full article
(This article belongs to the Special Issue Sensors for Health and Environment Monitoring)
Show Figures

Figure 1

21 pages, 1589 KB  
Review
Wearable Orofacial Technology and Orthodontics
by Sabarinath Prasad, Sivakumar Arunachalam, Thomas Boillat, Ahmed Ghoneima, Narayan Gandedkar and Samira Diar-Bakirly
Dent. J. 2023, 11(1), 24; https://doi.org/10.3390/dj11010024 - 10 Jan 2023
Cited by 17 | Viewed by 8340
Abstract
Wearable technology to augment traditional approaches are increasingly being added to the arsenals of treatment providers. Wearable technology generally refers to electronic systems, devices, or sensors that are usually worn on or are in close proximity to the human body. Wearables may be [...] Read more.
Wearable technology to augment traditional approaches are increasingly being added to the arsenals of treatment providers. Wearable technology generally refers to electronic systems, devices, or sensors that are usually worn on or are in close proximity to the human body. Wearables may be stand-alone or integrated into materials that are worn on the body. What sets medical wearables apart from other systems is their ability to collect, store, and relay information regarding an individual’s current body status to other devices operating on compatible networks in naturalistic settings. The last decade has witnessed a steady increase in the use of wearables specific to the orofacial region. Applications range from supplementing diagnosis, tracking treatment progress, monitoring patient compliance, and better understanding the jaw’s functional and parafunctional activities. Orofacial wearable devices may be unimodal or incorporate multiple sensing modalities. The objective data collected continuously, in real time, in naturalistic settings using these orofacial wearables provide opportunities to formulate accurate and personalized treatment strategies. In the not-too-distant future, it is anticipated that information about an individual’s current oral health status may provide patient-centric personalized care to prevent, diagnose, and treat oral diseases, with wearables playing a key role. In this review, we examine the progress achieved, summarize applications of orthodontic relevance and examine the future potential of orofacial wearables. Full article
Show Figures

Graphical abstract

31 pages, 8677 KB  
Review
Textile Materials for Wireless Energy Harvesting
by Yusuke Yamada
Electron. Mater. 2022, 3(4), 301-331; https://doi.org/10.3390/electronicmat3040026 - 8 Oct 2022
Cited by 8 | Viewed by 8751
Abstract
Wireless energy harvesting, a technique to generate direct current (DC) electricity from ambient wireless signals, has recently been featured as a potential solution to reduce the battery size, extend the battery life, or replace batteries altogether for wearable electronics. Unlike other energy harvesting [...] Read more.
Wireless energy harvesting, a technique to generate direct current (DC) electricity from ambient wireless signals, has recently been featured as a potential solution to reduce the battery size, extend the battery life, or replace batteries altogether for wearable electronics. Unlike other energy harvesting techniques, wireless energy harvesting has a prominent advantage of ceaseless availability of ambient signals, but the common form of technology involves a major challenge of limited output power because of a relatively low ambient energy density. Moreover, the archetypal wireless energy harvesters are made of printed circuit boards (PCBs), which are rigid, bulky, and heavy, and hence they are not eminently suitable for body-worn applications from both aesthetic and comfort points of view. In order to overcome these limitations, textile-based wireless energy harvesting architectures have been proposed in the past decade. Being made of textile materials, this new class of harvesters can be seamlessly integrated into clothing in inherently aesthetic and comfortable forms. In addition, since clothing offers a large surface area, multiple harvesting units can be deployed to enhance the output power. In view of these unique and irreplaceable benefits, this paper reviews key recent progress in textile-based wireless energy harvesting strategies for powering body-worn electronics. Comparisons with other power harvesting technologies, historical development, fundamental principles of operation and techniques for fabricating textile-based wireless power harvesters are first recapitulated, followed by a review on the principal advantages, challenges, and opportunities. It is one of the purposes of this paper to peruse the current state-of-the-art and build a scientific knowledge base to aid further advancement of power solutions for wearable electronics. Full article
Show Figures

Graphical abstract

Back to TopTop