Skip to Content
You are currently on the new version of our website. Access the old version .

790 Results Found

  • Article
  • Open Access
2,008 Views
13 Pages

Bone Compatibility of Experimental Ti–Ag and Ti–Cu Alloy Dental Implants in a Beagle Dog Model

  • Yasumitsu Ohtsuka,
  • Taichi Tenkumo,
  • Masatoshi Takahashi,
  • Yasuhiro Nakanishi and ,
  • Hiroaki Takebe and
  • Takashi Nezu
  • + 1 author+ 0 author

Titanium–silver (Ti–Ag) and titanium–copper (Ti–Cu) alloys have been developed to improve the mechanical properties and machinability of titanium (Ti) for dental applications while maintaining corrosion resistance comparable t...

(This article belongs to the Special Issue Functional Dental Materials for Orthodontics and Implants)
  • Article
  • Open Access
20 Citations
6,550 Views
10 Pages

Biomechanical Evaluation of Ti-Nb-Sn Alloy Implants with a Low Young’s Modulus

  • Kenta Takahashi,
  • Naru Shiraishi,
  • Risa Ishiko-Uzuka,
  • Takahisa Anada and ,
  • Osamu Suzuki,
  • Hiroshi Masumoto and
  • Keiichi Sasaki
  • + 2 authors+ 0 author

12 March 2015

Dental implants are widely used and are a predictable treatment in various edentulous cases. Occlusal overload may be causally related to implant bone loss and a loss of integration. Stress concentrations may be diminished using a mechanobiologicall...

(This article belongs to the Special Issue Biomaterials for Tissue Engineering)
  • Article
  • Open Access
1 Citations
2,392 Views
18 Pages

Material Characterization and Technological Properties of Biocompatible Ti-12Al-42Nb Spherical Powder Alloy for Additive Manufacturing of Personal Medical Implants

  • Alexander Anokhin,
  • Andrey Kirsankin,
  • Elena Kukueva,
  • Alexander Luk’yanov and ,
  • Maria Chuvikina,
  • Elena Ermakova,
  • Svetlana Strelnikova and
  • Stepan Kupreenko
  • + 3 authors+ 0 author

31 January 2025

The paper focuses on material characterization and technology properties of a new Ti-12Al-42Nb spherical powder alloy for additive manufacturing of personal medical implants. The electrode induction melting inert gas atomization (EIGA) method was use...

  • Review
  • Open Access
236 Citations
17,429 Views
13 Pages

13 August 2012

Dental implants made from binary titanium-zirconium (TiZr) alloys have shown promise as a high strength, yet biocompatible alternative to pure titanium, particularly for applications requiring small diameter implants. The aim of this review is to sum...

(This article belongs to the Special Issue Titanium Materials for Biomedical Application)
  • Article
  • Open Access
13 Citations
3,739 Views
11 Pages

Relationship between the Composition and Elastic Modulus of TiZrTa Alloys for Implant Materials

  • Jinzhu Zhao,
  • Kaiyang Liu,
  • Meining Ding,
  • Lixia Yin and
  • Shunxing Liang

23 September 2022

The elastic modulus is a key factor influencing the applications of implant materials because of the weakening effect of stress shielding. Ti and its alloys are good potential implant materials thanks to their low elastic modulus and fine biocompatib...

(This article belongs to the Section Structural Integrity of Metals)
  • Review
  • Open Access
47 Citations
5,041 Views
16 Pages

Developing Nanostructured Ti Alloys for Innovative Implantable Medical Devices

  • Ruslan Z. Valiev,
  • Egor A. Prokofiev,
  • Nikita A. Kazarinov,
  • Georgy I. Raab and ,
  • Timur B. Minasov and
  • Josef Stráský
  • + 1 author+ 0 author

21 February 2020

Recent years have witnessed much progress in medical device manufacturing and the needs of the medical industry urges modern nanomaterials science to develop novel approaches for improving the properties of existing biomaterials. One of the ways to e...

(This article belongs to the Special Issue Alloys for Biomedical Application)
  • Article
  • Open Access
7 Citations
2,414 Views
15 Pages

14 March 2023

Nanoporous TiO2 film is deposited on grade 5 Ti6Al4V implant alloy by electrochemical oxidation. The nanopores of the film, as highlighted by electron microscopy, have a mean diameter of 58.6 nm, which is measured and calculated from an average value...

  • Review
  • Open Access
19 Citations
4,047 Views
17 Pages

22 July 2022

Titanium alloys are useful for application in orthopedic implants. However, complications, such as prosthetic infections and aseptic loosening, often occur after orthopedic devices are implanted. Therefore, innovation in surface modification techniqu...

(This article belongs to the Special Issue Advanced Biomaterials for Medical Applications)
  • Article
  • Open Access
19 Citations
3,306 Views
9 Pages

26 March 2020

Ti, Ni, and Ti/Ni plasma immersion ion implantation is carried out on the AM60 magnesium alloy with a 6 × 1016 ions/cm2 fluence and energy of 35 keV. The corrosion and wear properties of the ion-implanted samples are determined systematically b...

(This article belongs to the Section High-Energy Beam Surface Engineering and Coatings)
  • Article
  • Open Access
1 Citations
937 Views
30 Pages

12 September 2026

In this work, multi-material joints of three biocompatible low-modulus titanium alloys—Ti15Ta, Ti10Ta2Nb2Zr, and Ti13Nb13Zr5Cu—were produced and systematically investigated by laser powder bed fusion (LPBF) for the development of function...

(This article belongs to the Special Issue Advances in Additive Manufacturing for Metallic Materials and Their Applications (4th Edition))
  • Article
  • Open Access
1 Citations
1,622 Views
23 Pages

Structure–Property–Function Evaluation of a β-Type Ti-Nb-Zr Alloy for Dental Implant Applications with Short-Term Clinical Validation

  • Deukwon Jo,
  • Soo-Hwan Byun,
  • Sang-Yoon Park,
  • Jong-Hee Kim and ,
  • Mijoo Kim,
  • Hyo-Jung Lee,
  • Young-Kyun Kim,
  • Byoung-Eun Yang and
  • Yang-Jin Yi
  • + 4 authors+ 0 author

Titanium-based alloys are widely used in dental implantology; however, the mechanical limitations of commercially pure titanium (cpTi) and unresolved concerns regarding stress shielding remain. This study evaluated the structure–property–...

(This article belongs to the Special Issue Next-Generation Biomaterials and Digital Innovations for Maxillofacial Reconstruction and Regeneration)
  • Review
  • Open Access
31 Citations
9,650 Views
14 Pages

The Trends of TiZr Alloy Research as a Viable Alternative for Ti and Ti16 Zr Roxolid Dental Implants

  • Daniela Ionita,
  • Cristian Pirvu,
  • Andrei Bogdan Stoian and
  • Ioana Demetrescu

24 April 2020

Despite many discussions about Ti versus Zr, Ti remains the golden standard for dental implants. With the extended use of implants, their rejection in peri-implantitis due to material properties is going to be an important part of oral health problem...

(This article belongs to the Special Issue Micro- and Nano-Coatings for Technological and Biomedical Applications)
  • Article
  • Open Access
16 Citations
4,230 Views
11 Pages

Study on Osseointegration Capability of β-Type Ti–Nb–Zr–Ta–Si Alloy for Orthopedic Implants

  • Yu Sun,
  • Qingping Liu,
  • Zhenglei Yu,
  • Luquan Ren and ,
  • Xin Zhao and
  • Jincheng Wang
  • + 1 author+ 0 author

19 January 2024

Osseointegration is the basic condition for orthopedic implants to maintain long-term stability. In order to achieve osseointegration, a low elastic modulus is the most important performance indicator. It is difficult for traditional titanium alloys...

(This article belongs to the Topic Clinical and Experimental Research in Dentistry and Bioactive Materials)
  • Article
  • Open Access
9 Citations
3,500 Views
17 Pages

The Impact of Al2O3 Particles from Grit-Blasted Ti6Al7Nb (Alloy) Implant Surfaces on Biocompatibility, Aseptic Loosening, and Infection

  • Boštjan Kocjančič,
  • Klemen Avsec,
  • Barbara Šetina Batič,
  • Darja Feizpour and ,
  • Matjaž Godec,
  • Veronika Kralj-Iglič,
  • Rok Podlipec,
  • Andrej Cör,
  • Mojca Debeljak and
  • Drago Dolinar
  • + 7 authors+ 2 authors

26 October 2023

For the improvement of surface roughness, titanium joint arthroplasty (TJA) components are grit-blasted with Al2O3 (corundum) particles during manufacturing. There is an acute concern, particularly with uncemented implants, about polymeric, metallic,...

(This article belongs to the Section Biomaterials)
  • Article
  • Open Access
13 Citations
4,293 Views
10 Pages

Wear Resistance of Ti–6Al–4V Alloy Ball Heads for Use in Implants

  • Svetlana Skvortsova,
  • Aleksei Orlov,
  • Georgii Valyano,
  • Victor Spektor and
  • Natalia Mamontova

The effect of thermohydrogen treatment and vacuum ion–plasma nitriding on the determination of the volume and surface structure of ball heads made of Ti–6Al–4V alloy was studied. It was found that the submicrocrystalline structure f...

  • Article
  • Open Access
32 Citations
3,675 Views
17 Pages

Laser-Deposited Beta Type Ti-42Nb Alloy with Anisotropic Mechanical Properties for Pioneering Biomedical Implants with a Very Low Elastic Modulus

  • Felipe Arias-González,
  • Alejandra Rodríguez-Contreras,
  • Miquel Punset,
  • José María Manero and ,
  • Óscar Barro,
  • Mónica Fernández-Arias,
  • Fernando Lusquiños,
  • Javier Gil and
  • Juan Pou
  • + 4 authors+ 0 author

14 October 2022

Present commercial titanium alloy implants have an elastic modulus higher than 100 GPa, whereas that of the cortical bone is much smaller (17–28 GPa). This elastic modulus mismatch produces a stress shielding effect and the resorption of the bo...

(This article belongs to the Special Issue Advances in Laser Processing)
  • Article
  • Open Access
16 Citations
7,161 Views
17 Pages

29 June 2016

We present here—designed, manufactured, and tested by our research team—the Ti-alloy prototype of the multispiked connecting scaffold (MSC-Scaffold) interfacing the components of resurfacing arthroplasty (RA) endoprostheses with bone. The spikes of t...

(This article belongs to the Section Biomaterials)
  • Article
  • Open Access
1 Citations
1,302 Views
43 Pages

Effect of Rare-Earth Element Microdoping on Ti–6Al–7Nb Alloys for Biomedical Applications: Materials Characterization and In Vivo Biocompatibility Tests

  • Alexander Anokhin,
  • Andrey Kirsankin,
  • Elena Ermakova,
  • Maria Chuvikina and ,
  • Alexander Luk’yanov,
  • Svetlana Strelnikova,
  • Elena Kukueva,
  • Nataliya Kononovich,
  • Konstantin Kravchuk and
  • Joydip Joardar
  • + 5 authors+ 0 author

12 February 2026

The paper focuses on materials characterization and in vivo biocompatibility tests of Ti–6Al–7Nb–0.3REE wt.% alloys (REEs—Y, Ce, La) for use as a promising material to produce personalized medical implants and shed light on po...

(This article belongs to the Section Metals and Alloys)
  • Article
  • Open Access
16 Citations
4,581 Views
24 Pages

25 November 2024

This study investigates the effects of various surface modification techniques on the Ti-6Al-4V alloy for biomedical applications. Mechanical treatments (sandblasting, shot peening) and electrochemical corrosion using different electrolytes were empl...

(This article belongs to the Collection Dental Composites and Adhesives in Dentistry)
  • Article
  • Open Access
5 Citations
3,158 Views
12 Pages

Electrochemical Behaviour and Direct Cell Viability Analysis of Hybrid Implants Made of Ti-6Al-4V Lattices Infiltrated with a Bioabsorbable Zn-Based Alloy

  • Noa Gabay Bass,
  • Galit Katarivas Levy,
  • Tomer Ron,
  • Razi Vago and ,
  • Jeremy Goldman,
  • Amnon Shirizly and
  • Eli Aghion
  • + 2 authors+ 0 author

16 October 2022

Biodegradable metals are being developed for biomedical implants or components of implants. Biodegradable zinc-based materials, in particular, have been shown to promote bone regeneration in orthopaedic applications. Here, we investigated the potenti...

(This article belongs to the Special Issue Corrosion Science and Engineering: Recent Research, Insights, and Challenges)
  • Feature Paper
  • Article
  • Open Access
56 Citations
7,113 Views
14 Pages

3 October 2017

The modern medical industry successfully utilizes Laser Powder Bed Fusion (LPBF) to manufacture complex custom implants. Ti6Al4V is one of the most commonly used biocompatible alloys. In surgery practice, infection at the bone–implant interface is on...

(This article belongs to the Special Issue Perspectives on Additively Manufactured Metallic Materials)
  • Article
  • Open Access
10 Citations
3,390 Views
19 Pages

19 August 2021

The term “osseointegrated implants” mainly relates to structural systems that contain open spaces, which enable osteoblasts and connecting tissue to migrate during natural bone growth. Consequently, the coherency and bonding strength between the impl...

(This article belongs to the Topic Metallurgical and Materials Engineering)
  • Article
  • Open Access
105 Citations
12,920 Views
20 Pages

Mechanical Properties of a Newly Additive Manufactured Implant Material Based on Ti-42Nb

  • Christian Schulze,
  • Markus Weinmann,
  • Christoph Schweigel,
  • Olaf Keßler and
  • Rainer Bader

13 January 2018

The application of Ti-6Al-4V alloy or commercially pure titanium for additive manufacturing enables the fabrication of complex structural implants and patient-specific implant geometries. However, the difference in Young’s modulus of α + β-phase Ti a...

(This article belongs to the Special Issue Perspectives on Additively Manufactured Metallic Materials)
  • Review
  • Open Access
8 Citations
3,116 Views
35 Pages

Research Progress of the Coatings Fabricated onto Titanium and/or Titanium Alloy Surfaces in Biomaterials for Medical Applications for Anticorrosive Applications

  • Qin Rao,
  • Jinshuang Zhang,
  • Yaqing Chen,
  • Yujin Yang and ,
  • Xu Chen,
  • Donghao Liu,
  • Ruilu Zhu,
  • Ang Li,
  • Yanping Lv and
  • Shunli Zheng
  • + 5 authors+ 0 author

Titanium (Ti) and its alloys have attracted more interest, as they are widely employed as biomaterials due to their great biocompatibility, excellent strength ratio, and lightweight. However, corrosion occurs slowly due to an electrochemical reaction...

(This article belongs to the Special Issue Innovative Coatings for Corrosion Protection of Alloy Surfaces)
  • Review
  • Open Access
269 Citations
21,055 Views
35 Pages

Recent Advancements in Materials and Coatings for Biomedical Implants

  • Kamalan Kirubaharan Amirtharaj Mosas,
  • Ashok Raja Chandrasekar,
  • Arish Dasan,
  • Amirhossein Pakseresht and
  • Dušan Galusek

21 May 2022

Metallic materials such as stainless steel (SS), titanium (Ti), magnesium (Mg) alloys, and cobalt-chromium (Co-Cr) alloys are widely used as biomaterials for implant applications. Metallic implants sometimes fail in surgeries due to inadequate biocom...

(This article belongs to the Special Issue Bioceramics, Bioglasses and Gels for Tissue Engineering)
  • Article
  • Open Access
1,236 Views
20 Pages

Influence of Chemical Composition on the Physical–Mechanical Properties of Some Experimental Titanium Alloys for Dental Implants

  • Vlad-Gabriel Vasilescu,
  • Lucian Toma Ciocan,
  • Andreia Cucuruz,
  • Florin Miculescu and ,
  • Alexandru Paraschiv,
  • Gheorghe Matache,
  • Marian Iulian Neacșu,
  • Elisabeta Vasilescu,
  • Marina Imre and
  • Claudiu Ștefan Turculeț
  • + 6 authors+ 1 author

3 February 2026

Background/Objectives: The main objective of optimizing the composition of dental implants is to improve tissue compatibility for enhanced biological/biochemical performance. In this context, research on the development of new titanium alloys in dent...

(This article belongs to the Special Issue Dental Materials Design and Application)
  • Review
  • Open Access
71 Citations
13,150 Views
29 Pages

A Comprehensive Review of Surface Modification Techniques for Enhancing the Biocompatibility of 3D-Printed Titanium Implants

  • Shuai Long,
  • Jiang Zhu,
  • Yiwan Jing,
  • Si He and ,
  • Lijia Cheng and
  • Zheng Shi
  • + 1 author+ 0 author

9 November 2023

The advent of three-dimensional (3D) printing technology has revolutionized the production of customized titanium (Ti) alloy implants. The success rate of implantation and the long-term functionality of these implants depend not only on design and ma...

(This article belongs to the Special Issue Advances in Surface Engineering and Biocompatible Coatings for Biomedical Applications)
  • Article
  • Open Access
19 Citations
3,452 Views
16 Pages

23 October 2019

The oxide film resistance (RP) and capacitance (CCPE) diagrams of implantable metals (commercially pure Ti, four types of Ti alloys, Co–28Cr–6Mo alloy, and stainless steel) were investigated by electrochemical impedance spectroscopy (EIS)...

  • Article
  • Open Access
2 Citations
827 Views
24 Pages

The Effect of the Er3+:YAG Laser Decontamination Process on the Surface of Titanium Alloys, Depending on the Exposure Parameters

  • Paulina Sobierajska,
  • Maciej Dobrzynski,
  • Kinga Grzech-Lesniak,
  • Kinga Sekula and ,
  • Damian Szymanski,
  • Wojciech Zakrzewski,
  • Krzysztof D. Dudek,
  • Jacek Matys,
  • Maria Szymonowicz and
  • Rafal J. Wiglusz
  • + 7 authors+ 2 authors

16 February 2026

The dynamic development of laser therapy in dentistry is associated, among other factors, with the bactericidal effect of the energy emitted by laser devices. Therefore, they are also helpful for decontamination. They are increasingly used in the tre...

(This article belongs to the Section Manufacturing Processes and Systems)
  • Review
  • Open Access
106 Citations
9,444 Views
29 Pages

Surface Modification of Biomedical Ti and Ti Alloys: A Review on Current Advances

  • Jingyuan Xu,
  • Jiawen Zhang,
  • Yangfan Shi,
  • Jincheng Tang and ,
  • Danni Huang,
  • Ming Yan and
  • Matthew S. Dargusch
  • + 2 authors+ 0 author

25 February 2022

Ti is widely used as a material for orthopedic implants. As rapid and effective osseointegration is a key factor for the successful application of implants, biologically inert Ti materials start to show inherent limitations, such as poor surface cell...

  • Article
  • Open Access
13 Citations
3,203 Views
15 Pages

Selected Physicochemical Properties of Diamond Like Carbon (DLC) Coating on Ti-13Nb-13Zr Alloy Used for Blood Contacting Implants

  • Magdalena Antonowicz,
  • Roksana Kurpanik,
  • Witold Walke,
  • Marcin Basiaga and ,
  • Jozef Sondor and
  • Zbigniew Paszenda
  • + 1 author+ 0 author

11 November 2020

Despite high interest in the issues of hemocompatibility of titanium implants, particularly those made of the Ti-13Nb-13Zr alloy, the applied methods of surface modification still do not always guarantee the physicochemical properties required for th...

(This article belongs to the Special Issue Fabrication and Machining of Metal Matrix Composites)
  • Article
  • Open Access
14 Citations
3,234 Views
25 Pages

Assessment of Microstructural, Mechanical and Electrochemical Properties of Ti–42Nb Alloy Manufactured by Electron Beam Melting

  • Maria Kozadaeva,
  • Maria Surmeneva,
  • Dmitriy Khrapov,
  • Vladimir Rybakov and ,
  • Roman Surmenev,
  • Andrey Koptyug,
  • Alina Vladescu (Dragomir),
  • Cosmin Mihai Cotrut,
  • Alexander Tyurin and
  • Irina Grubova
  • + 5 authors+ 0 author

4 July 2023

The β-type Ti–42Nb alloy has been successfully manufactured from pre-alloyed powder using the E-PBF method for the first time. This study presents thorough microstructural investigations employing diverse methodologies such as EDS, XRD, TE...

  • Article
  • Open Access
36 Citations
4,862 Views
19 Pages

Synthesis and Characterization of a Novel Biocompatible Alloy, Ti-Nb-Zr-Ta-Sn

  • Yuliya Y. Khrunyk,
  • Sabrina Ehnert,
  • Stella V. Grib,
  • Anatoly G. Illarionov and ,
  • Stepan I. Stepanov,
  • Artemiy A. Popov,
  • Maxim A. Ryzhkov,
  • Sergey V. Belikov,
  • Zeqian Xu and
  • Andreas K. Nüssler
  • + 6 authors+ 1 author

30 September 2021

Many current-generation biomedical implants are fabricated from the Ti-6Al-4V alloy because it has many attractive properties, such as low density and biocompatibility. However, the elastic modulus of this alloy is much larger than that of the surrou...

(This article belongs to the Special Issue Biomaterials and Regenerative Medicine)
  • Article
  • Open Access
  • Best Paper Award
24 Citations
6,441 Views
18 Pages

Titanium Implant Alloy Modified by Electrochemically Deposited Functional Bioactive Calcium Phosphate Coatings

  • Jozefina Katić,
  • Sara Krivačić,
  • Željka Petrović,
  • Dajana Mikić and
  • Marijan Marciuš

17 March 2023

Calcium phosphate-based (CaP) bioceramic materials are widely used in the field of bone regeneration, both in orthopaedics and in dentistry, due to their good biocompatibility, osseointegration and osteoconduction. The formation of CaP coatings on hi...

(This article belongs to the Special Issue Biomimetic Approaches in Coatings Synthesis)
  • Article
  • Open Access
3 Citations
2,334 Views
18 Pages

Biocompatibility Evaluation of Novel Experimental Titanium Alloys for Dental Implants

  • Vlad-Gabriel Vasilescu,
  • Lucian Toma Ciocan,
  • Andreea Mihaela Custura,
  • Miruna Stan and ,
  • Florin Miculescu,
  • Cosmin Mihai Cotrut,
  • Diana Maria Vranceanu,
  • Elisabeta Vasilescu,
  • Marina Imre and
  • Silviu Mirel Pițuru
  • + 5 authors+ 0 author

22 December 2025

Background/Objectives: The purpose of this study was to assess the in vitro biocompatibility and corrosion resistance of five titanium alloys that have been recently developed for dental implant applications, whose compositions were designed to align...

(This article belongs to the Special Issue Dental Materials Design and Application)
  • Review
  • Open Access
58 Citations
12,875 Views
44 Pages

Dental Implants: Modern Materials and Methods of Their Surface Modification

  • Catherine Sotova,
  • Oleg Yanushevich,
  • Natella Kriheli,
  • Sergey Grigoriev and ,
  • Vladimir Evdokimov,
  • Olga Kramar,
  • Margarita Nozdrina,
  • Nikita Peretyagin,
  • Nika Undritsova and
  • Pavel Peretyagin
  • + 6 authors+ 1 author

27 November 2023

The development of dental implantology is based on the detailed study of the interaction of implants with the surrounding tissues and methods of osteogenesis stimulation around implants, which has been confirmed by the increasing number of scientific...

(This article belongs to the Section Biomaterials)
  • Article
  • Open Access
304 Views
27 Pages

Additively manufactured implants may be vulnerable to localized corrosion within narrow gaps, yet the critical crevice geometry and the effectiveness of multilayer coatings under such conditions remain insufficiently understood. This study compares t...

(This article belongs to the Special Issue Advanced Metallic Biomaterials: Characterization, Optimization and Biomedical Applications)
  • Article
  • Open Access
12 Citations
3,692 Views
15 Pages

Cell Adhesion and Initial Bone Matrix Deposition on Titanium-Based Implants with Chitosan–Collagen Coatings: An In Vitro Study

  • Francesca Veronesi,
  • Silvia Brogini,
  • Angela De Luca,
  • Davide Bellini and ,
  • Veronica Casagranda,
  • Milena Fini and
  • Gianluca Giavaresi
  • + 2 authors+ 0 author

In orthopedics, titanium (Ti)-alloy implants, are often considered as the first-choice candidates for bone tissue engineering. An appropriate implant coating enhances bone matrix ingrowth and biocompatibility, improving osseointegration. Collagen I (...

(This article belongs to the Special Issue Biomaterials: Synthesis, Application and Biocompatibility)
  • Article
  • Open Access
6 Citations
2,755 Views
14 Pages

Numerical Investigation of Fatigue Behavior in Ti-6Al-4V Orthopedic Hip Implants Subjected to Different Environments

  • Tamara Smoljanić,
  • Ljubica Milović,
  • Simon Sedmak,
  • Aleksa Milovanović and ,
  • Katarina Čolić,
  • Zoran Radaković and
  • Aleksandar Sedmak
  • + 2 authors+ 0 author

1 August 2024

In this paper, hip implants made of Ti-6Al-4V titanium alloy are analyzed numerically using Extended Finite Element Method XFEM. The combined effect of corrosion and fatigue was considered here since this is a common cause of failure of hip implants....

  • Feature Paper
  • Review
  • Open Access
241 Citations
15,776 Views
49 Pages

3 October 2022

Metallic materials are among the most crucial engineering materials widely utilized as biomaterials owing to their significant thermal conductivity, mechanical characteristics, and biocompatibility. Although these metallic biomedical implants, such a...

(This article belongs to the Special Issue Recent Advances in Functional Surfaces and Interfaces)
  • Article
  • Open Access
3 Citations
2,475 Views
14 Pages

10 March 2021

Biocompatible β-type Ti-45Nb alloy with a low elastic modulus is promising in alleviating the stress shielding effect of Ti-based hard-tissue replacement implants. In this work, the ultra-fine-grained (UFG) microstructures with different grain sizes...

  • Article
  • Open Access
2 Citations
850 Views
25 Pages

Selective Laser Melting of Multi-Material Ti15Ta/Ti6Al4V Structures for Biomedical Applications: From Process Parameters to Mechanical Properties and Biological Response

  • Igor Polozov,
  • Victoria Nefyodova,
  • Anton Zolotarev,
  • Victoria Sokolova and ,
  • Sergey Chibrikov and
  • Anatoly Popovich
  • + 1 author+ 0 author

8 March 2026

Multi-material structures based on titanium alloys represent a promising approach for the fabrication of functionally graded orthopedic implants capable of combining high mechanical strength with reduced stiffness to minimize the stress-shielding eff...

(This article belongs to the Special Issue Manufacturing Processes of Metallic Materials (2nd Edition))
  • Article
  • Open Access
22 Citations
6,225 Views
19 Pages

Titanium Nitride Coatings on CoCrMo and Ti6Al4V Alloys: Effects on Wear and Ion Release

  • Mohammed AbuAlia,
  • Spencer Fullam,
  • Filippo Cinotti,
  • Noora Manninen and
  • Markus A. Wimmer

While titanium nitride (TiN) coatings are well known for their biocompatibility and excellent mechanical properties, their wear particle and debris release in orthopedic implants remains a matter of active investigation. This study addresses the effi...

  • Article
  • Open Access
13 Citations
3,801 Views
13 Pages

Investigation into the Hybrid Production of a Superelastic Shape Memory Alloy with Additively Manufactured Structures for Medical Implants

  • Isabell Hamann,
  • Felix Gebhardt,
  • Manuel Eisenhut,
  • Peter Koch and ,
  • Juliane Thielsch,
  • Christin Rotsch,
  • Welf-Guntram Drossel,
  • Christoph-Eckhard Heyde and
  • Mario Leimert
  • + 4 authors+ 0 author

5 June 2021

The demographic change in and the higher incidence of degenerative bone disease have resulted in an increase in the number of patients with osteoporotic bone tissue causing. amongst other issues, implant loosening. Revision surgery to treat and corre...

  • Article
  • Open Access
15 Citations
3,957 Views
20 Pages

11 March 2024

Titanium is the most used material for implant production. To increase its biocompatibility, continuous research on new coatings has been performed by the scientific community. The aim of the present paper is to prepare new coatings on the surfaces o...

(This article belongs to the Special Issue New Insight into Design and Properties of Nanomaterials (Second Edition))
  • Review
  • Open Access
95 Citations
11,195 Views
30 Pages

Development of AM Technologies for Metals in the Sector of Medical Implants

  • Irene Buj-Corral,
  • Aitor Tejo-Otero and
  • Felip Fenollosa-Artés

23 May 2020

Additive manufacturing (AM) processes have undergone significant progress in recent years, having been implemented in sectors as diverse as automotive, aerospace, electrical component manufacturing, etc. In the medical sector, different devices are p...

(This article belongs to the Special Issue State-of-Art within 3D Printing and Advanced Machining Processes)
  • Review
  • Open Access
6 Citations
2,448 Views
22 Pages

Beyond Biocompatibility: Immune Dysregulation, Oxidative Stress, and Tissue Intolerance Associated with Ti-6Al-4V Dental Implants—A Critical Review and Perspective

  • Żaneta Anna Mierzejewska,
  • Łukasz Woźniak,
  • Jérôme R. Lechien,
  • Jan Borys and ,
  • Kamila Łukaszuk and
  • Bożena Antonowicz
  • + 1 author+ 0 author

Titanium and its alloys are widely used in dental implantology due to their favorable mechanical properties and well-documented long-term clinical performance. Among them, Ti-6Al-4V is particularly common in load-bearing applications. Nevertheless, a...

(This article belongs to the Section Health Outcomes of Antioxidants and Oxidative Stress)
  • Proceeding Paper
  • Open Access
30 Views
11 Pages

Gentamicin-Loaded Nanotubular Oxide on Ti-24Zr-10Nb-2Sn Alloy: In Vitro Activity Against Staphylococcus aureus 

  • Frank E. Melendez-Anzures,
  • Enrique Lopez-Cuellar,
  • Luis A. López-Pavón,
  • María P. Barrón-González and
  • Yadira Quiñones-Gutiérrez

Postoperative implant infections are strongly associated with bacterial adhesion and biofilm formation on metallic surfaces, particularly by Staphylococcus aureus. This study evaluated gentamicin-loaded nanotubular oxide formed on a Ti-24Zr-10Nb-2Sn...

(This article belongs to the Proceedings of The 2nd International Online Conference on Functional Biomaterials)
  • Article
  • Open Access
86 Citations
6,470 Views
18 Pages

On the Investigation of Surface Integrity of Ti6Al4V ELI Using Si-Mixed Electric Discharge Machining

  • Muhammad Umar Farooq,
  • Mohammad Pervez Mughal,
  • Naveed Ahmed,
  • Nadeem Ahmad Mufti and ,
  • Abdulrahman M. Al-Ahmari and
  • Yong He
  • + 1 author+ 0 author

27 March 2020

Surface modification is given vital importance in the biomedical industry to cope with surface tissue growth problems. Conventionally, basic surface treatment methods are used which include physical and chemical deposition. The major drawbacks associ...

  • Article
  • Open Access
512 Views
17 Pages

Effect of Sintering Temperature on Densification, Microstructure, and Corrosion Behavior of Ti6Al4V/20Cu Composites Fabricated by Powder Metallurgy

  • Victor Manuel Solorio,
  • Hector Javier Vergara-Hernández,
  • Elena Mihalcea,
  • Julio Villalobos-Brito and ,
  • Francisco Alvarado-Hernandez,
  • Jose Luis Cabezas-Villa,
  • Gilberto González-Gómez,
  • Mario Misael Machado-López and
  • Luis Olmos
  • + 4 authors+ 0 author

10 July 2026

Copper alloying of Ti6Al4V via liquid-phase sintering (LPS) is a promising route to enhance densification and mechanical properties for biomedical implants. This study investigates the effect of sintering temperature (900–1100 °C) on the de...

(This article belongs to the Special Issue Powder Metallurgy and Advanced Materials)

of 16