Titanium–silver (Ti–Ag) and titanium–copper (Ti–Cu) alloys have been developed to improve the mechanical properties and machinability of titanium (Ti) for dental applications while maintaining corrosion resistance comparable t...
Titanium–silver (Ti–Ag) and titanium–copper (Ti–Cu) alloys have been developed to improve the mechanical properties and machinability of titanium (Ti) for dental applications while maintaining corrosion resistance comparable t...
Dental implants are widely used and are a predictable treatment in various edentulous cases. Occlusal overload may be causally related to implant bone loss and a loss of integration. Stress concentrations may be diminished using a mechanobiologicall...
The paper focuses on material characterization and technology properties of a new Ti-12Al-42Nb spherical powder alloy for additive manufacturing of personal medical implants. The electrode induction melting inert gas atomization (EIGA) method was use...
Dental implants made from binary titanium-zirconium (TiZr) alloys have shown promise as a high strength, yet biocompatible alternative to pure titanium, particularly for applications requiring small diameter implants. The aim of this review is to sum...
The elastic modulus is a key factor influencing the applications of implant materials because of the weakening effect of stress shielding. Ti and its alloys are good potential implant materials thanks to their low elastic modulus and fine biocompatib...
Recent years have witnessed much progress in medical device manufacturing and the needs of the medical industry urges modern nanomaterials science to develop novel approaches for improving the properties of existing biomaterials. One of the ways to e...
Nanoporous TiO2 film is deposited on grade 5 Ti6Al4V implant alloy by electrochemical oxidation. The nanopores of the film, as highlighted by electron microscopy, have a mean diameter of 58.6 nm, which is measured and calculated from an average value...
Titanium alloys are useful for application in orthopedic implants. However, complications, such as prosthetic infections and aseptic loosening, often occur after orthopedic devices are implanted. Therefore, innovation in surface modification techniqu...
Ti, Ni, and Ti/Ni plasma immersion ion implantation is carried out on the AM60 magnesium alloy with a 6 × 1016 ions/cm2 fluence and energy of 35 keV. The corrosion and wear properties of the ion-implanted samples are determined systematically b...
In this work, multi-material joints of three biocompatible low-modulus titanium alloys—Ti15Ta, Ti10Ta2Nb2Zr, and Ti13Nb13Zr5Cu—were produced and systematically investigated by laser powder bed fusion (LPBF) for the development of function...
Titanium-based alloys are widely used in dental implantology; however, the mechanical limitations of commercially pure titanium (cpTi) and unresolved concerns regarding stress shielding remain. This study evaluated the structure–property–...
Despite many discussions about Ti versus Zr, Ti remains the golden standard for dental implants. With the extended use of implants, their rejection in peri-implantitis due to material properties is going to be an important part of oral health problem...
Osseointegration is the basic condition for orthopedic implants to maintain long-term stability. In order to achieve osseointegration, a low elastic modulus is the most important performance indicator. It is difficult for traditional titanium alloys...
For the improvement of surface roughness, titanium joint arthroplasty (TJA) components are grit-blasted with Al2O3 (corundum) particles during manufacturing. There is an acute concern, particularly with uncemented implants, about polymeric, metallic,...
The effect of thermohydrogen treatment and vacuum ion–plasma nitriding on the determination of the volume and surface structure of ball heads made of Ti–6Al–4V alloy was studied. It was found that the submicrocrystalline structure f...
Present commercial titanium alloy implants have an elastic modulus higher than 100 GPa, whereas that of the cortical bone is much smaller (17–28 GPa). This elastic modulus mismatch produces a stress shielding effect and the resorption of the bo...
We present here—designed, manufactured, and tested by our research team—the Ti-alloy prototype of the multispiked connecting scaffold (MSC-Scaffold) interfacing the components of resurfacing arthroplasty (RA) endoprostheses with bone. The spikes of t...
The paper focuses on materials characterization and in vivo biocompatibility tests of Ti–6Al–7Nb–0.3REE wt.% alloys (REEs—Y, Ce, La) for use as a promising material to produce personalized medical implants and shed light on po...
This study investigates the effects of various surface modification techniques on the Ti-6Al-4V alloy for biomedical applications. Mechanical treatments (sandblasting, shot peening) and electrochemical corrosion using different electrolytes were empl...
Biodegradable metals are being developed for biomedical implants or components of implants. Biodegradable zinc-based materials, in particular, have been shown to promote bone regeneration in orthopaedic applications. Here, we investigated the potenti...
The modern medical industry successfully utilizes Laser Powder Bed Fusion (LPBF) to manufacture complex custom implants. Ti6Al4V is one of the most commonly used biocompatible alloys. In surgery practice, infection at the bone–implant interface is on...
The term “osseointegrated implants” mainly relates to structural systems that contain open spaces, which enable osteoblasts and connecting tissue to migrate during natural bone growth. Consequently, the coherency and bonding strength between the impl...
The application of Ti-6Al-4V alloy or commercially pure titanium for additive manufacturing enables the fabrication of complex structural implants and patient-specific implant geometries. However, the difference in Young’s modulus of α + β-phase Ti a...
Titanium (Ti) and its alloys have attracted more interest, as they are widely employed as biomaterials due to their great biocompatibility, excellent strength ratio, and lightweight. However, corrosion occurs slowly due to an electrochemical reaction...
Metallic materials such as stainless steel (SS), titanium (Ti), magnesium (Mg) alloys, and cobalt-chromium (Co-Cr) alloys are widely used as biomaterials for implant applications. Metallic implants sometimes fail in surgeries due to inadequate biocom...
Background/Objectives: The main objective of optimizing the composition of dental implants is to improve tissue compatibility for enhanced biological/biochemical performance. In this context, research on the development of new titanium alloys in dent...
The advent of three-dimensional (3D) printing technology has revolutionized the production of customized titanium (Ti) alloy implants. The success rate of implantation and the long-term functionality of these implants depend not only on design and ma...
The oxide film resistance (RP) and capacitance (CCPE) diagrams of implantable metals (commercially pure Ti, four types of Ti alloys, Co–28Cr–6Mo alloy, and stainless steel) were investigated by electrochemical impedance spectroscopy (EIS)...
The dynamic development of laser therapy in dentistry is associated, among other factors, with the bactericidal effect of the energy emitted by laser devices. Therefore, they are also helpful for decontamination. They are increasingly used in the tre...
Ti is widely used as a material for orthopedic implants. As rapid and effective osseointegration is a key factor for the successful application of implants, biologically inert Ti materials start to show inherent limitations, such as poor surface cell...
Despite high interest in the issues of hemocompatibility of titanium implants, particularly those made of the Ti-13Nb-13Zr alloy, the applied methods of surface modification still do not always guarantee the physicochemical properties required for th...
The β-type Ti–42Nb alloy has been successfully manufactured from pre-alloyed powder using the E-PBF method for the first time. This study presents thorough microstructural investigations employing diverse methodologies such as EDS, XRD, TE...
Many current-generation biomedical implants are fabricated from the Ti-6Al-4V alloy because it has many attractive properties, such as low density and biocompatibility. However, the elastic modulus of this alloy is much larger than that of the surrou...
Calcium phosphate-based (CaP) bioceramic materials are widely used in the field of bone regeneration, both in orthopaedics and in dentistry, due to their good biocompatibility, osseointegration and osteoconduction. The formation of CaP coatings on hi...
Background/Objectives: The purpose of this study was to assess the in vitro biocompatibility and corrosion resistance of five titanium alloys that have been recently developed for dental implant applications, whose compositions were designed to align...
The development of dental implantology is based on the detailed study of the interaction of implants with the surrounding tissues and methods of osteogenesis stimulation around implants, which has been confirmed by the increasing number of scientific...
Additively manufactured implants may be vulnerable to localized corrosion within narrow gaps, yet the critical crevice geometry and the effectiveness of multilayer coatings under such conditions remain insufficiently understood. This study compares t...
In orthopedics, titanium (Ti)-alloy implants, are often considered as the first-choice candidates for bone tissue engineering. An appropriate implant coating enhances bone matrix ingrowth and biocompatibility, improving osseointegration. Collagen I (...
In this paper, hip implants made of Ti-6Al-4V titanium alloy are analyzed numerically using Extended Finite Element Method XFEM. The combined effect of corrosion and fatigue was considered here since this is a common cause of failure of hip implants....
Metallic materials are among the most crucial engineering materials widely utilized as biomaterials owing to their significant thermal conductivity, mechanical characteristics, and biocompatibility. Although these metallic biomedical implants, such a...
Biocompatible β-type Ti-45Nb alloy with a low elastic modulus is promising in alleviating the stress shielding effect of Ti-based hard-tissue replacement implants. In this work, the ultra-fine-grained (UFG) microstructures with different grain sizes...
Multi-material structures based on titanium alloys represent a promising approach for the fabrication of functionally graded orthopedic implants capable of combining high mechanical strength with reduced stiffness to minimize the stress-shielding eff...
While titanium nitride (TiN) coatings are well known for their biocompatibility and excellent mechanical properties, their wear particle and debris release in orthopedic implants remains a matter of active investigation. This study addresses the effi...
The demographic change in and the higher incidence of degenerative bone disease have resulted in an increase in the number of patients with osteoporotic bone tissue causing. amongst other issues, implant loosening. Revision surgery to treat and corre...
Titanium is the most used material for implant production. To increase its biocompatibility, continuous research on new coatings has been performed by the scientific community. The aim of the present paper is to prepare new coatings on the surfaces o...
Additive manufacturing (AM) processes have undergone significant progress in recent years, having been implemented in sectors as diverse as automotive, aerospace, electrical component manufacturing, etc. In the medical sector, different devices are p...
Titanium and its alloys are widely used in dental implantology due to their favorable mechanical properties and well-documented long-term clinical performance. Among them, Ti-6Al-4V is particularly common in load-bearing applications. Nevertheless, a...
Postoperative implant infections are strongly associated with bacterial adhesion and biofilm formation on metallic surfaces, particularly by Staphylococcus aureus. This study evaluated gentamicin-loaded nanotubular oxide formed on a Ti-24Zr-10Nb-2Sn...
Surface modification is given vital importance in the biomedical industry to cope with surface tissue growth problems. Conventionally, basic surface treatment methods are used which include physical and chemical deposition. The major drawbacks associ...
Copper alloying of Ti6Al4V via liquid-phase sintering (LPS) is a promising route to enhance densification and mechanical properties for biomedical implants. This study investigates the effect of sintering temperature (900–1100 °C) on the de...