Skip to Content

2,402 Results Found

  • Article
  • Open Access
1 Citations
1,500 Views
5 Pages

Electric vehicle (EV) motors are subject to extreme and variable loads, resulting in degradation of winding insulation due to high temperatures. This paper describes research on a new conductive composite sensor, which uses insulation resin as a matr...

  • Review
  • Open Access
95 Citations
11,941 Views
26 Pages

26 August 2016

The condition of the internal cellulosic paper and oil insulation are of concern for the performance of power transformers. Over the years, a number of methods have been developed to diagnose and monitor the degradation/aging of the transformer inter...

  • Review
  • Open Access
13 Citations
2,430 Views
36 Pages

Research Progress and Prospect of Condition Assessment Techniques for Oil–Paper Insulation Used in Power Systems: A Review

  • Zaijun Jiang,
  • Xin Li,
  • Heng Zhang,
  • Enze Zhang,
  • Chuying Liu,
  • Xianhao Fan and
  • Jiefeng Liu

26 April 2024

Oil–paper insulation is the critical insulation element in the modern power system. Under a harsh operating environment, oil–paper insulation will deteriorate gradually, resulting in electrical accidents. Thus, it is important to evaluate...

  • Article
  • Open Access
13 Citations
4,324 Views
15 Pages

12 December 2019

The aging kinetics model is of great interest to scholars since it is capable of describing the variation law between the degree of polymerization (DP) and the aging duration of transformer polymer (cellulose) insulation. However, it is difficult to...

  • Article
  • Open Access
12 Citations
4,750 Views
16 Pages

14 February 2018

The life expectancy of a transformer is largely depended on the service life of transformer polymer insulation materials. Nowadays, several papers have reported that the traditional system poles obtained from polarization and depolarization current (...

  • Article
  • Open Access
9 Citations
3,001 Views
17 Pages

2 June 2022

Insulators are the basis of the stable operation of transmission lines, and it is particularly important to regularly detect the insulation performance of insulators. After several years of research, contactless space electric field detection technol...

  • Article
  • Open Access
5 Citations
5,706 Views
20 Pages

26 January 2022

In building acoustics, two different problems usually arise. There is a need to comply with established sound insulation parameters, but there are also legislative conditions concerning reverberation time. It is therefore necessary to acoustically in...

  • Article
  • Open Access
11 Citations
3,225 Views
16 Pages

25 May 2018

Icing can adversely influence electric power system security. Two main issues are caused by icing: the overload of transmission lines, and the reduction in the insulation ability of the insulators. Most previous research has focused on the flashover...

  • Article
  • Open Access
21 Citations
3,727 Views
20 Pages

4 October 2021

Insulator detection is one of the most significant issues in high-voltage transmission line inspection using unmanned aerial vehicles (UAVs) and has attracted attention from researchers all over the world. The state-of-the-art models in object detect...

  • Article
  • Open Access
10 Citations
2,695 Views
11 Pages

9 November 2021

As a result of lightning strikes, pollution, and ice, overhead distribution wires might be short-circuited and trip. As a result, researchers have developed a new lightning protection composite insulator. There is still a need to test its pollution a...

  • Article
  • Open Access
5 Citations
3,577 Views
19 Pages

31 July 2020

Frequency-domain spectroscopy (FDS) is demonstrated to be affected by electrode polarization and conductance behavior in the low-frequency ranges, which causes the unreliable prediction results of transformer cellulose insulation. In order to solve t...

  • Article
  • Open Access
5 Citations
1,752 Views
17 Pages

8 November 2024

Overhead transmission line insulators are non-conductive materials that separate conductors from grounded transmission towers. Once in operation, they frequently experience environmental pollution and electrical or mechanical stress. Since adverse op...

  • Article
  • Open Access
11 Citations
5,671 Views
20 Pages

12 December 2022

This paper proposes a comprehensive procedure to assess the condition of gas insulated switchgear (GIS) equipment by using the conventional weight and score method and introducing a conditional factor to improve the accuracy of the health index evalu...

  • Article
  • Open Access
5 Citations
3,544 Views
14 Pages

4 November 2020

Newly designed and constructed buildings are subjected to increasingly strict regulations which emphasize the minimization and, where possible, the elimination of wasteful energy consumption, thus resulting in a decrease in emissions. Thermal insulat...

  • Article
  • Open Access
27 Citations
4,387 Views
12 Pages

Icing Condition Assessment of In-Service Glass Insulators Based on Graphical Shed Spacing and Graphical Shed Overhang

  • Yanpeng Hao,
  • Jie Wei,
  • Xiaolan Jiang,
  • Lin Yang,
  • Licheng Li,
  • Junke Wang,
  • Hao Li and
  • Ruihai Li

2 February 2018

Icing on transmission lines might lead to ice flashovers of insulators, collapse of towers, tripping faults of transmission lines, and other accidents. Shed spacing and shed overhang of insulators are clues for evaluating the probability of ice flash...

  • Article
  • Open Access
85 Citations
12,812 Views
15 Pages

Photoluminescence Spectroscopy Measurements for Effective Condition Assessment of Transformer Insulating Oil

  • Abdelrahman M. Alshehawy,
  • Diaa-Eldin A. Mansour,
  • Mohsen Ghali,
  • Matti Lehtonen and
  • Mohamed M. F. Darwish

21 April 2021

Condition assessment of insulating oil is crucial for the reliable long-term operation of power equipment, especially power transformers. Under thermal aging, critical degradation in oil properties, including chemical, physical, and dielectric proper...

  • Article
  • Open Access
18 Citations
2,553 Views
21 Pages

Fuzzy Algorithms for Diagnosis of Furnace Transformer Insulation Condition

  • Alexander S. Karandaev,
  • Igor M. Yachikov,
  • Andrey A. Radionov,
  • Ivan V. Liubimov,
  • Nikolay N. Druzhinin and
  • Ekaterina A. Khramshina

11 May 2022

Implementation of the smart transformer concept is critical for the deployment of IIoT-based smart grids. Top manufacturers of power electrics develop and adopt online monitoring systems. Such systems become part of high-voltage grid and unit transfo...

  • Article
  • Open Access
14 Citations
3,381 Views
13 Pages

21 February 2022

The findings of the analysis of data on the accident rate of power transformers indicate that one of the main causes of their failures is a decrease in the dielectric strength of the insulation. To reduce failures and extend the service life of power...

  • Article
  • Open Access
3 Citations
1,549 Views
17 Pages

Detecting defects in transmission line insulators is crucial to prevent power grid failures as power systems continue to expand. This study introduces YOL011n-SSA, an enhanced insulator defect detection technique method that addresses the challenges...

  • Review
  • Open Access
213 Citations
13,877 Views
29 Pages

Review of Physicochemical-Based Diagnostic Techniques for Assessing Insulation Condition in Aged Transformers

  • Janvier Sylvestre N’cho,
  • Issouf Fofana,
  • Yazid Hadjadj and
  • Abderrahmane Beroual

13 May 2016

A power transformer outage has a dramatic financial consequence not only for electric power systems utilities but also for interconnected customers. The service reliability of this important asset largely depends upon the condition of the oil-paper i...

  • Article
  • Open Access
55 Citations
5,459 Views
16 Pages

8 October 2017

Conventional dielectric response measurement techniques, for instance, recovery voltage measurement (RVM), frequency domain spectroscopy (FDS) and polarization–depolarization current (PDC) are effective nondestructive insulation monitoring techniques...

  • Article
  • Open Access
12 Citations
3,442 Views
13 Pages

Condition Assessment of HV Bushings with Solid Insulation based on the SVM and the FDS Methods

  • Jan Subocz,
  • Andrzej Mrozik,
  • Patryk Bohatyrewicz and
  • Marek Zenker

15 February 2020

This paper presents the dielectric response of the insulation of bushings as an effect of the simulated long-term aging process. The experiment was conducted under a condition of a high temperature difference between the current circuit and the cover...

  • Article
  • Open Access
30 Citations
9,462 Views
20 Pages

Diagnosis of Insulation Condition of MV Switchgears by Application of Different Partial Discharge Measuring Methods and Sensors

  • Fernando Álvarez Gómez,
  • Ricardo Albarracín-Sánchez,
  • Fernando Garnacho Vecino and
  • Ricardo Granizo Arrabé

28 February 2018

Partial discharges (PD) measurement provides valuable information for the condition assessment of the insulation status of high-voltage (HV) electrical installations. During the last three decades, several PD sensors and measuring techniques have bee...

  • Article
  • Open Access
3 Citations
1,838 Views
14 Pages

29 January 2025

ETICS is a popular external wall insulation system, which is not without possible defects and damages. A frequent cause, direct or indirect, of damage to buildings is the impact of water (moisture). This article presents, among others, the results of...

  • Article
  • Open Access
15 Citations
5,515 Views
15 Pages

Condition Assessment of Paper Insulation in Oil-Immersed Power Transformers Based on the Iterative Inversion of Resistivity

  • Jiangjun Ruan,
  • Shuo Jin,
  • Zhiye Du,
  • Yiming Xie,
  • Lin Zhu,
  • Yu Tian,
  • Ruohan Gong,
  • Guannan Li and
  • Min Xiong

10 April 2017

The resistivity of oil impregnated paper will decrease during its aging process. This paper takes paper resistivity as an assessment index to evaluate the insulation condition of oil impregnated paper in power transformer. The feasibility of this met...

  • Article
  • Open Access
31 Citations
5,934 Views
17 Pages

11 November 2017

Polarization-depolarization current (PDC) measurements are now being used as a diagnosis tool to predict the ageing condition of transformer oil-paper insulation. Unfortunately, it is somewhat difficult to obtain the ageing condition of transformer c...

  • Article
  • Open Access
14 Citations
2,856 Views
16 Pages

Insulation Condition Assessment in Inverter-Fed Motors Using the High-Frequency Common Mode Current: A Case Study

  • Mariam Saeed,
  • Daniel Fernández,
  • Juan Manuel Guerrero,
  • Ignacio Díaz and
  • Fernando Briz

18 January 2024

The use of the common mode current for stator winding insulation condition assessment has been extensively studied. Two main approaches have been followed. The first models the electric behavior of ground-wall insulation as an equivalent RC circuit;...

  • Feature Paper
  • Article
  • Open Access
6 Citations
4,006 Views
19 Pages

29 April 2021

This paper presents a nonlinear numerical study on the moment resistance of composite steel-concrete beam using fire insulation subjected to various fire scenarios and basic loading conditions. The temperature-dependent material properties of fire in...

  • Article
  • Open Access
425 Views
21 Pages

26 December 2025

The accurate assessment of the aging state of epoxy resin insulation is critical for the safe operation of cast resin dry-type transformers. This study investigates the evolution of activation energy during thermal aging and its correlation with insu...

  • Article
  • Open Access
842 Views
26 Pages

25 July 2025

To address the limitations of low detection efficiency and poor spatial resolution of traditional cable insulation diagnosis methods, a novel cable insulation diagnosis method based on impedance spectroscopy has been proposed. An impedance spectrosco...

  • Article
  • Open Access
10 Citations
2,173 Views
15 Pages

Accurate Assessment of Moisture Content and Degree of Polymerization in Power Transformers via Dielectric Response Sensing

  • Anantawat Kunakorn,
  • Sarawuth Pramualsingha,
  • Peerawut Yutthagowith,
  • Phethai Nimsanong and
  • Supat Kittiratsatcha

3 October 2023

Power transformers are essential apparatuses used to transfer electrical energy from one voltage-level circuit to another. For reliable systems, preventive maintenance of the transformers is required to ensure good services of all mechanical, electri...

  • Article
  • Open Access
2 Citations
2,707 Views
15 Pages

Assessment of the Technical Condition of High-Voltage Insulators during Operation

  • Dmitry Ivanov,
  • Aleksandr Golenishchev-Kutuzov,
  • Marat Sadykov,
  • Danil Yaroslavsky and
  • Tatyana Galieva

11 November 2022

During the operation process of high-voltage insulators, the characteristics of assessing their technical state are evaluated by using remote contactless monitoring and by subsequent forecasting of their residual life based on the developed set of di...

  • Article
  • Open Access
2 Citations
3,428 Views
21 Pages

28 March 2022

In buildings with the solar heat collection/insulation energy-saving window (SHC/IESW), when the insulation device is placed at night in winter, a double-wall structure façade (DSF) is formed between the glass and the insulation curtain, and t...

  • Article
  • Open Access
495 Views
13 Pages

9 December 2025

The Debye model and its modified forms are widely applied to interpret relaxation polarization processes in dielectric media. However, these models generally require prior assumptions regarding the number of polarization branches, which makes it diff...

  • Article
  • Open Access
5 Citations
3,185 Views
20 Pages

13 February 2024

Insulators on overhead power lines have long been exposed to the outdoors and are susceptible to pollution and salt contamination. Due to factors such as wind and gravity, pollution in the atmosphere gradually deposits on the surface of the insulator...

  • Article
  • Open Access
457 Views
26 Pages

25 November 2025

We determined the reference characteristics of the loss tangent and the real component of the complex permittivity of the cellulose-insulating oil–water nanodroplet nanocomposite with a moisture content of 5.17% by weight in pressboard. Such a...

  • Article
  • Open Access
11 Citations
4,528 Views
20 Pages

Machine Learning-Based Classification of Electrical Low Voltage Cable Degradation

  • Egnonnumi Lorraine Codjo,
  • Bashir Bakhshideh Zad,
  • Jean-François Toubeau,
  • Bruno François and
  • François Vallée

15 May 2021

Low voltage distribution networks have not been traditionally designed to accommodate the large-scale integration of decentralized photovoltaic (PV) generations. The bidirectional power flows in existing networks resulting from the load demand and PV...

  • Article
  • Open Access
2 Citations
1,737 Views
15 Pages

To quantitatively describe the frequency domain spectroscopy (FDS) characteristics of transformer oil-paper insulation under varying temperature, moisture, and aging conditions, a modified Cole–Cole model is introduced. This model decomposes th...

  • Article
  • Open Access
331 Views
20 Pages

Multi-Parameter Assessment and Validation of Cable Insulation Using Game Theory and Fuzzy Comprehensive Evaluation

  • Qianqiu Shao,
  • Songhai Fan,
  • Zongxi Zhang,
  • Fenglian Liu,
  • Jinkui Lu,
  • Zhengzheng Fu and
  • Pinlei Lv

16 December 2025

Accurate assessment of high-voltage cable insulation condition is essential for safe operation in complex tunnel environments. Traditional methods relying on single diagnostic indicators and fixed weighting schemes often suffer from limited accuracy...

  • Article
  • Open Access
12 Citations
3,129 Views
20 Pages

While personal protective equipment (PPE) protects healthcare workers from viruses, it also increases the risk of heat stress. In this study, the effects of environmental heat stress, the insulation of the PPE inner-garment layer, and the personal co...

  • Article
  • Open Access
15 Citations
3,168 Views
12 Pages

30 August 2021

Many sectors, such as transportation systems, are undergoing rapid electrification due to the need for the mitigation of CO2 emissions. To ensure safe and reliable operation, the electrical equipment must be able to work under various environmental c...

  • Article
  • Open Access
8 Citations
5,909 Views
18 Pages

Insulation Performance of Building Components and Effect on the Cooling Load of Homes in Saudi Arabia

  • Abdulhamid Al-Abduljabbar,
  • Majid Al-Mogbel,
  • Syed Noman Danish and
  • Abdelrahman El-Leathy

24 March 2023

A common practice in the construction of residential and commercial buildings in Saudi Arabia is to insulate the outer walls and windows only. Other building components such as the roof, columns and slabs, and doors are usually neglected. Moreover, v...

  • Article
  • Open Access
1 Citations
3,014 Views
17 Pages

27 December 2021

Hot streaks and rotor–stator interaction have a great influence on the aerothermal performance of turbine blades. Previous investigations have conducted limited study of the film-cooled blade. To investigate the combined effects of a hot streak...

  • Article
  • Open Access
2 Citations
2,104 Views
18 Pages

Improved Isothermal Relaxation Current Measurement Based on Isolated Circuit for Nondestructive Evaluation of High-Voltage Cable Insulation

  • Huangjing Gu,
  • Yongkang Zhang,
  • Bin Shen,
  • Ziqi Liu,
  • Yunjie Zhou,
  • Xiaodi Wang,
  • Xinyang Zhu and
  • Yalin Wang

3 December 2023

The Isothermal Relaxation Current (IRC) method, as a non-destructive condition evaluation method based on insulation dielectric response, has been applied in the maintenance of power cables. However, the relaxation current is usually conducted throug...

  • Article
  • Open Access
26 Citations
7,752 Views
17 Pages

22 June 2019

Apart from being used as an oil stock for bio-fuels production, an annual crop plant Brassica napus, thought to be an agro-waste, and used either as an animal feed, soil fertilizer or biomass for combustion and thermal energy production. Alternativel...

  • Review
  • Open Access
10 Citations
4,626 Views
23 Pages

29 September 2024

Inverter-fed machines are widely used in electric vehicle drive systems and have shown a trend toward high voltage and frequency in recent years. They are subjected to multiple types of stress during operation, causing potential short-circuit fault d...

  • Article
  • Open Access
3 Citations
2,884 Views
14 Pages

Study of Acoustic Prototypes Based on Plastic Cap Waste

  • Romina Del Rey,
  • José Enrique Crespo Amorós,
  • Joan Escales Tur and
  • Jesús Alba

This paper presents the initial prototypes of solutions designed using plastic caps, seeking acoustic applications for both airborne sound insulation and the acoustic conditioning of rooms. Plastic caps are a waste product from the packaging sector a...

  • Article
  • Open Access
2 Citations
1,088 Views
26 Pages

15 January 2025

Adverse climatic conditions, particularly excessive water and frost, necessitate the design of thick protective sub-ballast layers when dealing with frost-susceptible subgrade surfaces, especially when using standard natural materials (crushed aggreg...

  • Article
  • Open Access
202 Citations
26,391 Views
28 Pages

25 March 2015

Partial discharge (PD) measurements provide valuable information for assessing the condition of high voltage (HV) insulation systems, contributing to their quality assurance. Different PD measuring techniques have been developed in the last years spe...

  • Article
  • Open Access
4 Citations
1,478 Views
17 Pages

29 January 2024

This paper covers the design of binder formulations and technology for low-energy building materials based on alkaline aluminosilicate binders developed for special uses. The microstructure of the binders was investigated using scanning electron and...

of 49