Skip Content
You are currently on the new version of our website. Access the old version .

804 Results Found

  • Review
  • Open Access
16 Citations
4,022 Views
13 Pages

Application of the Active-Fluidics System in Phacoemulsification: A Review

  • Yu Luo,
  • Guangcan Xu,
  • Hongyu Li,
  • Tianju Ma,
  • Zi Ye and
  • Zhaohui Li

12 January 2023

The fluidics system is an indispensable and primary component of phacoemulsification. Both the gravity-fluidics system and active-fluidics system are commonly used in practice. The irrigation pressure of the gravity-fluidics system is determined by t...

  • Article
  • Open Access
9 Citations
3,553 Views
11 Pages

Different Regimes of Opto-fluidics for Biological Manipulation

  • John T. Winskas,
  • Hao Wang,
  • Arsenii Zhdanov,
  • Surya Cheemalapati,
  • Andrew Deonarine,
  • Sandy Westerheide and
  • Anna Pyayt

21 November 2019

Metallic structures can be used for the localized heating of fluid and the controlled generation of microfluidic currents. Carefully designed currents can move and trap small particles and cells. Here we demonstrate a new bi-metallic substrate that a...

  • Article
  • Open Access
4 Citations
3,572 Views
11 Pages

Micelles Mediated Zone Fluidics Method for Hydrazine Determination in Environmental Samples

  • Theano D. Karakosta,
  • Christophoros Christophoridis,
  • Konstantinos Fytianos and
  • Paraskevas D. Tzanavaras

31 December 2019

An automated flow method for the determination of hydrazine based on the concept of zone-fluidics has been developed. The analyte reacts under flow conditions with p-dimethylamino benzaldehyde (25 mmol L−1) in micellar medium (100 mmol L...

  • Article
  • Open Access
18 Citations
3,218 Views
11 Pages

Fluorimetric Method for the Determination of Histidine in Random Human Urine Based on Zone Fluidics

  • Antonios Alevridis,
  • Apostolia Tsiasioti,
  • Constantinos K. Zacharis and
  • Paraskevas D. Tzanavaras

In the present study, the determination of histidine (HIS) by an on-line flow method based on the concept of zone fluidics is reported. HIS reacts fast with o-phthalaldehyde at a mildly basic medium (pH 7.5) and in the absence of additional nucleophi...

  • Article
  • Open Access
2 Citations
1,724 Views
12 Pages

18 December 2023

Fluidic and non-fluidic surface plasmon resonance measurements were realized for the same type of sensory layer and using the same mouse IgG antibody and anti-mouse IgG antibody biomolecular system. A comparison of the thicknesses of the anti-mouse I...

  • Article
  • Open Access
23 Citations
6,948 Views
15 Pages

Performance Study of a Fluidic Hammer Controlled by an Output-Fed Bistable Fluidic Oscillator

  • Xinxin Zhang,
  • Jianming Peng,
  • Dong Ge,
  • Kun Bo,
  • Kun Yin and
  • Dongyu Wu

20 October 2016

Using a no-moving-component output-fed bistable fluidic oscillator to control fluid flows into a parallel path has been recognized for a considerable time, but as yet it is not so widely adopted as its obvious benefits would deserve. This may be attr...

  • Feature Paper
  • Article
  • Open Access
8 Citations
2,922 Views
10 Pages

3 November 2019

A zone-fluidics (ZF) based automated fluorimetric sensor for the determination of pharmaceutically active adamantine derivatives, i.e., amantadine (AMA), memantine (MEM) and rimantadine (RIM) is reported. Discrete zones of the analytes and reagents (...

  • Article
  • Open Access
4 Citations
7,087 Views
12 Pages

Study of the Oxidative Forced Degradation of Glutathione in Its Nutraceutical Formulations Using Zone Fluidics and Green Liquid Chromatography

  • Apostolia Tsiasioti,
  • Constantinos K. Zacharis,
  • Anastasia-Stella Zotou and
  • Paraskevas D. Tzanavaras

In the present study, we report the results of our investigation of the oxidative forced degradation of glutathione in its nutraceutical formulations by two validated analytical methods. The first is based on the reaction of glutathione with o-phthal...

  • Article
  • Open Access
1 Citations
3,971 Views
13 Pages

A Fluidics-Based Double Flexural Membrane Piezoelectric Micromachined Ultrasonic Transducer (PMUT) for Wide-Bandwidth Underwater Acoustic Applications

  • Khairul Azman Ahmad,
  • Mohamad Faizal Abd Rahman,
  • Khairu Anuar Mohamed Zain,
  • Muhammad Naim Haron and
  • Asrulnizam Abd Manaf

19 August 2021

In acoustic receiver design, the receiving sensitivity and bandwidth are two primary parameters that determine the performance of a device. The trade-off between sensitivity and bandwidth makes the design very challenging, meaning it needs to be fine...

  • Article
  • Open Access
1 Citations
1,012 Views
16 Pages

8 March 2025

In the exploitation of deep geothermal energy from hot dry rock (HDR) reservoirs, traditional drilling methodologies exhibit a retarded penetration rate, posing a significant impediment to efficient energy extraction. The fluidic DTH hammer is recogn...

  • Article
  • Open Access
2 Citations
2,540 Views
13 Pages

5 February 2021

In the present research, a zone fluidics-based automated sensor for the analysis of captopril in in vitro dissolution samples is reported. Captopril is reacted under flow conditions with Ni(II) (10 mmol L−1) in alkaline medium (0.15% v/v NH3) to form...

  • Article
  • Open Access
33 Citations
6,899 Views
27 Pages

20 March 2020

The number of applications where fluidic oscillators are expected to be used in the future, is raising sharply, then their ability of interacting with the boundary layer to modify forces on bluff bodies, enhancing heat transfer or decreasing noise ge...

  • Article
  • Open Access
675 Views
14 Pages

20 August 2025

Purpose: To evaluate the efficiency and safety of high-fluidics ultrasound emulsification using slim-shaft-strong-bevel (SSSB) tip technology for nucleus workup through mini- and micro-incisions. Materials and Methods: 77 patients underwent immediate...

  • Article
  • Open Access
9 Citations
3,278 Views
13 Pages

Switching Action of a Bistable Fluidic Amplifier for Ultrasonic Testing

  • Thorge Schweitzer,
  • Marla Hörmann,
  • Benjamin Bühling and
  • Bernhard Bobusch

25 April 2021

Air-coupled ultrasonic testing is widely used in the industry for the non-destructive testing of compound materials. It provides a fast and efficient way to inspect large concrete civil infrastructures for damage that might lead to catastrophic failu...

  • Article
  • Open Access
1,858 Views
16 Pages

Fluidic Diode AICD Characteristic Curve Testing and Mathematical Modeling

  • Weigang Du,
  • Yongsheng An,
  • Peng Ji,
  • Runshi Huo and
  • Liyong Guan

17 July 2023

In order to investigate an efficient water control method suitable for the bottom water occurring during the production process of horizontal wells in bottom water reservoirs, the characteristic curves of a Fluidic Diode AICD (Automatic Inflow Contro...

  • Article
  • Open Access
4 Citations
3,956 Views
22 Pages

1 December 2021

In this paper, a fluidic capacitive inclination sensor is presented and compared to three types of silicon-based microelectromechanical system (MEMS) accelerometers. MEMS accelerometers are commonly used for tilt measurement. They can only be manufac...

  • Article
  • Open Access
3 Citations
2,147 Views
9 Pages

22 March 2022

Herein, we report a new automated flow method based on zone fluidics for the simultaneous determination of homocysteine and homocysteine thiolactone using fluorimetric detection (λext = 370 nm/λem = 480 nm). Homocysteine thiolactone is...

  • Article
  • Open Access
1 Citations
1,386 Views
29 Pages

15 January 2025

Fluidic oscillators have emerged as a prominent topic of research in the field of flow control, owing to their broad sweep range and enhanced control efficiency. However, the underlying mechanisms governing the operation of fluidic oscillators remain...

  • Article
  • Open Access
4 Citations
3,716 Views
23 Pages

7 February 2021

Flow separation control over a wall-mounted hump model was studied experimentally to assess the performance of fluidic oscillators (sweeping jet actuators). An array of fluidic oscillators was used to control flow separation. The results showed that...

  • Article
  • Open Access
2 Citations
4,478 Views
22 Pages

Influence of Fluidic Control in a Staged Lean Jet Engine Burner on Combustor Performance

  • Seiji Yoshida,
  • Christoph Hassa,
  • Takeshi Yamamoto,
  • Johannes Heinze and
  • Michael Schroll

1 November 2019

To improve the turn-down ratio of a lean combustor, which has the greatest potential for reducing NOx emissions from jet engines, fuel staging is commonly employed. To further extend the stable operation range, air staging with a fluidic element is a...

  • Review
  • Open Access
3 Citations
5,546 Views
21 Pages

9 August 2019

Fluidic signals transferred between mutually communicating components of fluidic circuits are nowadays still often in the format of continuously varied value of pressure or flow rate. Especially when transported over longer distances, these simple si...

  • Article
  • Open Access
8 Citations
3,059 Views
21 Pages

The Effects of Compressibility on the Performance and Modal Structures of a Sweeping Jet Emitted from Various Scales of a Fluidic Oscillator

  • Daniel J. Portillo,
  • Eugene Hoffman,
  • Matt Garcia,
  • Elijah LaLonde,
  • Christopher Combs and
  • R. Lyle Hood

21 July 2022

Investigations of fluidic oscillators, or sweeping jet actuators, have primarily been conducted within the incompressible flow regime, which limits the accuracy of estimating fluidic oscillator performance for compressible flows. The objective of thi...

  • Article
  • Open Access
3 Citations
2,668 Views
18 Pages

2 February 2022

Microfluidic biochips have been in the scientific spotlight for over two decades, and although technologically advanced, they still struggle to deliver on the promise for ubiquitous miniaturization and automation for the biomedical sector. One of the...

  • Review
  • Open Access
29 Citations
10,458 Views
33 Pages

Techniques of Fluidic Thrust Vectoring in Jet Engine Nozzles: A Review

  • Saadia Afridi,
  • Tariq Amin Khan,
  • Syed Irtiza Ali Shah,
  • Taimur Ali Shams,
  • Khawar Mohiuddin and
  • David John Kukulka

31 July 2023

Thrust vectoring innovations are demonstrated ideas that improve the projection of aerospace power with enhanced maneuverability, control effectiveness, survivability, performance, and stealth. Thrust vector control systems following a variety of con...

  • Article
  • Open Access
4 Citations
3,496 Views
19 Pages

9 March 2022

In this paper, we investigate the design of pennate topology fluidic artificial muscle bundles under spatial constraints. Soft fluidic actuators are of great interest to roboticists and engineers, due to their potential for inherent compliance and sa...

  • Article
  • Open Access
18 Citations
5,419 Views
12 Pages

5 April 2017

An axial oscillation tool is proved to be effective in solving problems associated with high friction and torque in the sliding drilling of a complex well. The fluidic axial oscillation tool, based on an output-fed bistable fluidic oscillator, is a t...

  • Review
  • Open Access
11 Citations
4,608 Views
16 Pages

9 February 2021

If a gas volume is distributed into many microbubbles of a sub-millimetre size, the total gas/liquid surface becomes very large. This increases overall heat and/or mass transport across the sum of surfaces. The paper discusses several applications in...

  • Feature Paper
  • Review
  • Open Access
10 Citations
4,100 Views
27 Pages

A Recent Approach towards Fluidic Microstrip Devices and Gas Sensors: A Review

  • Suleiman Aliyu Babale,
  • Kashif Nisar Paracha,
  • Sarosh Ahmad,
  • Sharul Kamal Abdul Rahim,
  • Zainab Yunusa,
  • Muhammad Nasir,
  • Adnan Ghaffar and
  • Abdenasser Lamkaddem

This paper aims to review some of the available tunable devices with emphasis on the techniques employed, fabrications, merits, and demerits of each technique. In the era of fluidic microstrip communication devices, versatility and stability have bec...

  • Article
  • Open Access
7 Citations
2,418 Views
14 Pages

18 August 2021

The present work investigated the effects of bending the outlet nozzles of fluidic oscillators installed on the NACA0015 airfoil with a flap on the flow control performance and, thus, the aerodynamic performance of the airfoil. The effects of bending...

  • Article
  • Open Access
3 Citations
1,524 Views
15 Pages

Stabilization of Fluidic Silty Sands with Cement and Steel Slag

  • Leilei Gu,
  • Xianjun Deng,
  • Mei Zhang,
  • Shengnian Wang,
  • Bin Li and
  • Jiufa Ji

26 October 2023

Fluidic silty sand is often difficult to use directly in engineering construction because of its low strength and plasticity index. This study employed steel slag to replace part of the cement in silty sand stabilization to broaden the feasibility of...

  • Article
  • Open Access
3 Citations
2,782 Views
17 Pages

18 February 2022

Static in vitro permeation experiments are commonly used to gain insights into the permeation properties of drug substances but exhibit limitations due to missing physiologic cell stimuli. Thus, fluidic systems integrating stimuli, such as physicoche...

  • Article
  • Open Access
6 Citations
2,550 Views
13 Pages

Analysis of Water Droplet Distribution in Wind for the Fluidic Sprinkler

  • Frank Agyen Dwomoh,
  • Shouqi Yuan,
  • Hong Li,
  • Xingye Zhu,
  • Junping Liu,
  • Richard Mensah and
  • Alexander Fordjour

26 November 2020

The fluidic sprinkler, a relatively new type of rotating sprinkler, has been the subject of quite a lot of research about its structural parameters, hydraulic characteristics, and water distribution profile, albeit under indoor conditions. The fluidi...

  • Article
  • Open Access
1 Citations
1,553 Views
12 Pages

Analysis of Fluid Replacement in Two Fluidic Chambers for Oblique–Incidence Reflectivity Difference (OI-RD) Biosensor

  • Haofeng Li,
  • Mengjing Xu,
  • Xiaohan Mai,
  • Hang Zhang,
  • Xiangdong Zhu,
  • Lan Mi,
  • Jiong Ma and
  • Yiyan Fei

21 March 2024

Optical biosensors have a significant impact on various aspects of our lives. In many applications of optical biosensors, fluidic chambers play a crucial role in facilitating controlled fluid delivery. It is essential to achieve complete liquid repla...

  • Article
  • Open Access
6 Citations
3,155 Views
20 Pages

Transient Characteristics of Fluidic Pintle Nozzle in a Solid Rocket Motor

  • Dongfeng Yan,
  • Zehang Zhao,
  • Anchen Song,
  • Fengming Li,
  • Lu Ye,
  • Ganchao Zhao and
  • Shan Ma

The fluidic pintle nozzle, a new method to control the thrust of a solid rocket motor, has been proposed in recent years by combining the pintle with the aerodynamic throat (fluidic throat). The study of static characteristics has proved that it has...

  • Article
  • Open Access
1 Citations
2,787 Views
8 Pages

8 November 2021

A low-cost polyethylene terephthalate fluidic sensor (PET-FS) is demonstrated for the concentration variation measurement on fluidic solutions. The PET-FS consisted of a triangular fluidic container attached with a birefringent PET thin layer. The PE...

  • Article
  • Open Access
2,816 Views
18 Pages

Modeling of Actuation Force, Pressure and Contraction of Fluidic Muscles Based on Machine Learning

  • Sandi Baressi Šegota,
  • Mario Ključević,
  • Dario Ogrizović and
  • Zlatan Car

In this paper, the dataset is collected from the fluidic muscle datasheet. This dataset is then used to train models predicting the pressure, force, and contraction length of the fluidic muscle, as three separate outputs. This modeling is performed w...

  • Article
  • Open Access
18 Citations
11,486 Views
20 Pages

21 March 2021

Fluidic oscillators have proven their capabilities and advantages in terms of the generation of oscillating jets without moving parts for many years, mainly in experimental studies. In this paper, the design, development, and integration of fluidic a...

  • Article
  • Open Access
40 Citations
11,060 Views
16 Pages

pH-Sensitive Hydrogel for Micro-Fluidic Valve

  • Yan Zhang,
  • Zishun Liu,
  • Somsak Swaddiwudhipong,
  • Haiyan Miao,
  • Zhiwei Ding and
  • Zhengzhi Yang

The deformation behavior of a pH-sensitive hydrogel micro-fluidic valve system is investigated using inhomogeneous gel deformation theory, in which the fluid-structure interaction (FSI) of the gel solid and fluid flow in the pipe is considered. We us...

  • Article
  • Open Access
23 Citations
3,593 Views
23 Pages

Fluidic Oscillators, Feedback Channel Effect under Compressible Flow Conditions

  • Josep M. Bergadà,
  • Masoud Baghaei,
  • Bhanu Prakash and
  • Fernando Mellibovsky

27 August 2021

Fluidic oscillators are often used to modify the forces fluid generates on any given bluff body; they can also be used as flow, pressure or acoustic sensors, with each application requiring a particular oscillator configuration. Regarding the fluidic...

  • Article
  • Open Access
22 Citations
5,024 Views
11 Pages

Frequency Characteristic of Resonant Micro Fluidic Chip for Oil Detection Based on Resistance Parameter

  • Zilei Yu,
  • Lin Zeng,
  • Hongpeng Zhang,
  • Guogang Yang,
  • Wenqi Wang and
  • Wanheng Zhang

Monitoring the working condition of hydraulic equipment is significance in industrial fields. The abnormal wear of the hydraulic system can be revealed by detecting the variety and size of micro metal debris in the hydraulic oil. We thus present the...

  • Article
  • Open Access
12 Citations
3,877 Views
19 Pages

A Numerical Study on the Characteristics of Air–Fuel Mixing Using a Fluidic Oscillator in Supersonic Flow Fields

  • Eun Cheol Lee,
  • Seung-Won Cha,
  • Hee-Soo Kwon,
  • Tae-Seong Roh and
  • Hyoung Jin Lee

13 December 2019

In this study, numerical simulations were conducted to confirm the possibility of improved mixing performance by using a fluidic oscillator as a fuel injector. Three-dimensional URANS non-reacting simulations were conducted to examine air–fuel...

  • Article
  • Open Access
2 Citations
2,457 Views
16 Pages

Numerical Research on the Jet-Mixing Mechanism of Convergent Nozzle Excited by a Fluidic Oscillator and an Air Tab

  • Ming Li,
  • Zhijun Lei,
  • Hanliu Deng,
  • Xiaoqing Ouyang,
  • Yanfeng Zhang,
  • Xingen Lu,
  • Gang Xu and
  • Junqiang Zhu

31 January 2023

Unsteady numerical simulations, coupled with the SST (Shear Stress Transport) k-ω turbulence model, were conducted to study the mixing-enhancement characteristics of the excited jet generated by the fluidic oscillator and the air tab in a singl...

  • Article
  • Open Access
1 Citations
3,072 Views
10 Pages

21 February 2023

We report on a compact two-electrode voltage clamping system composed of microfabricated electrodes and a fluidic device for Xenopus laevis oocytes. The device was fabricated by assembling Si-based electrode chips and acrylic frames to form fluidic c...

  • Feature Paper
  • Article
  • Open Access
10 Citations
3,422 Views
18 Pages

Characterization of Fluidic-Barrier-Based Particle Generation in Centrifugal Microfluidics

  • Masoud Madadelahi,
  • Javid Azimi-Boulali,
  • Marc Madou and
  • Sergio Omar Martinez-Chapa

The fluidic barrier in centrifugal microfluidic platforms is a newly introduced concept for making multiple emulsions and microparticles. In this study, we focused on particle generation application to better characterize this method. Because the phe...

  • Article
  • Open Access
80 Citations
6,822 Views
12 Pages

Temperature-Corrected Fluidic Glucose Sensor Based on Microwave Resonator

  • Chorom Jang,
  • Jin-Kwan Park,
  • Hee-Jo Lee,
  • Gi-Ho Yun and
  • Jong-Gwan Yook

9 November 2018

In this paper, a fluidic glucose sensor that is based on a complementary split-ring resonator (CSRR) is proposed for the microwave frequency region. The detection of glucose with different concentrations from 0 mg/dL to 400 mg/dL in a non-invasive ma...

  • Article
  • Open Access
15 Citations
3,847 Views
11 Pages

Synthesis and a Photo-Stability Study of Organic Dyes for Electro-Fluidic Display

  • Yong Deng,
  • Shi Li,
  • Dechao Ye,
  • Hongwei Jiang,
  • Biao Tang and
  • Guofu Zhou

11 January 2020

Electro-fluidic display (EFD) is one of the most promising reflective displays because of its full color and video speed. Colored EFD oil, which normally consists of soluble organic dyes and non-polar solvent, plays a critical role in color, electro-...

  • Article
  • Open Access
3 Citations
2,262 Views
17 Pages

17 February 2024

Contaminated autonomous-driving sensors frequently malfunction, resulting in accidents; these sensors need regular cleaning. The autonomous-driving sensor-cleaning nozzle currently used is the windshield-washer nozzle; few studies have focused on the...

  • Review
  • Open Access
12 Citations
5,506 Views
24 Pages

Flexible Fluidic-Type Strain Sensors for Wearable and Robotic Applications Fabricated with Novel Conductive Liquids: A Review

  • Afaque Manzoor Soomro,
  • Bushra Jawed,
  • Jahangeer Badar Soomro,
  • Jamshed Ahmed Ansari,
  • Faheem Ahmed,
  • Muhammad Waqas,
  • Hina Ashraf and
  • Suhail Almani

13 September 2022

Flexible strain sensors with high sensitivity, wide sensing range, and excellent long-term stability are highly anticipated due to their promising potential in user-friendly electronic skins, interactive wearable systems, and robotics. Fortunately, t...

  • Feature Paper
  • Article
  • Open Access
1,396 Views
16 Pages

15 September 2025

Microphysiological systems (MPSs), such as organ-on-a-chip platforms, are promising alternatives to animal testing for drug development and physiological research. The BioStellar™ Plate is a commercial MPS platform featuring an open-top culture...

of 17