Skip to Content

60 Results Found

  • Review
  • Open Access
96 Citations
11,822 Views
18 Pages

An Update on Nickel-Titanium Rotary Instruments in Endodontics: Mechanical Characteristics, Testing and Future Perspective—An Overview

  • Alessio Zanza,
  • Maurilio D’Angelo,
  • Rodolfo Reda,
  • Gianluca Gambarini and ,
  • Luca Testarelli and
  • Dario Di Nardo
  • + 1 author+ 0 author

Since the introduction of Nickel-Titanium alloy as the material of choice for the manufacturing of endodontic rotary instruments, the success rate of the root canal therapies has been significantly increased. This success mainly arises from the prope...

  • Review
  • Open Access
17 Citations
6,050 Views
16 Pages

30 March 2021

The aim of this review was to provide a detailed literature analysis of torque and force generation during nickel-titanium rotary root canal instrumentation. We followed Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guid...

(This article belongs to the Special Issue Innovative Techniques in Endodontics)
  • Article
  • Open Access
4 Citations
6,048 Views
9 Pages

Impact of Radial Lands on the Reduction of Torque/Force Generation of a Heat-Treated Nickel-Titanium Rotary Instrument

  • Taro Nakatsukasa,
  • Arata Ebihara,
  • Moe Sandar Kyaw,
  • Satoshi Omori and ,
  • Hayate Unno,
  • Shunsuke Kimura,
  • Keiichiro Maki and
  • Takashi Okiji
  • + 3 authors+ 0 author

3 March 2022

This study investigated the impact of a one-sided radial-landed cross-sectional design of a heat-treated nickel-titanium rotary instrument (JIZAI, MANI, Japan; JZ) on torque/force generation and canal-shaping ability, using an experimental non-landed...

(This article belongs to the Special Issue New Trends in Endodontic Materials and Clinical Endodontics)
  • Editorial
  • Open Access
5 Citations
3,548 Views
3 Pages

14 February 2022

During the last two decades, the field of the nickel–titanium (NiTi) rotary instruments has been thoroughly changed by the latest, exciting innovations in both manufacturing technologies and the knowledge of their mechanical performance [...]

  • Article
  • Open Access
21 Citations
4,617 Views
11 Pages

Mechanical and Metallurgical Evaluation of 3 Different Nickel-Titanium Rotary Instruments: An In Vitro and In Laboratory Study

  • Alessio Zanza,
  • Paola Russo,
  • Rodolfo Reda,
  • Paola Di Matteo and ,
  • Orlando Donfrancesco,
  • Pietro Ausiello and
  • Luca Testarelli
  • + 2 authors+ 0 author

An in-depth evaluation of the mechanical and metallurgical properties of NiTi instruments is fundamental to assess their performance and to compare recently introduced instrument with widespread ones. According to this, since there are no data on thi...

  • Article
  • Open Access
2 Citations
1,157 Views
11 Pages

Thermal Treatment Prevents Effects of Downward Loads on the Screw-In Force Generation and Canal-Centering Ability of Nickel–Titanium Rotary Instruments

  • Keiichiro Maki,
  • Arata Ebihara,
  • Yanshan Luo,
  • Yuka Kasuga and ,
  • Hayate Unno,
  • Satoshi Omori,
  • Shunsuke Kimura and
  • Takashi Okiji
  • + 3 authors+ 0 author

31 July 2025

This study aimed to examine how downward load applied during instrumentation affects the stress generation and shaping properties in thermally treated and non-treated NiTi rotary instruments. ProTaper Universal (PTU; non-thermally treated) and ProTap...

(This article belongs to the Topic Advances in Dental Materials)
  • Article
  • Open Access
7 Citations
2,713 Views
9 Pages

Effect of Rotational Modes on Torque/Force Generation and Canal Centering Ability during Rotary Root Canal Instrumentation with Differently Heat-Treated Nickel–Titanium Instruments

  • Satoshi Omori,
  • Arata Ebihara,
  • Keiko Hirano,
  • Yuka Kasuga and ,
  • Hayate Unno,
  • Taro Nakatsukasa,
  • Shunsuke Kimura,
  • Keiichiro Maki,
  • Takao Hanawa and
  • Takashi Okiji
  • + 5 authors+ 0 author

2 October 2022

This study aimed to evaluate how various rotational modes influence the torque/force production and shaping ability of ProTaper Universal (PTU; non-heat-treated) and ProTaper Gold (PTG; heat-treated) nickel–titanium instruments. J-shaped resin...

(This article belongs to the Special Issue Mechanical and Metallurgical Behavior of Endodontic & Restorative Materials)
  • Article
  • Open Access
4 Citations
4,575 Views
8 Pages

20 November 2020

Nickel-titanium (NiTi) endodontic rotary instruments are used extensively in root canal procedures by both general dentists and specialists. However, their vulnerability to fracture is the major reason for clinicians’ concern regarding their us...

(This article belongs to the Special Issue Contemporary Endodontic Materials)
  • Article
  • Open Access
8 Citations
3,505 Views
8 Pages

Shaping Ability and Debris Extrusion of New Rotary Nickel-Titanium Root Canal Instruments

  • Sebastian Bürklein,
  • David Donnermeyer,
  • Tim Julian Hentschel and
  • Edgar Schäfer

24 February 2021

The aim was to evaluate the canal straightening and the amount of apically extruded debris associated with five rotary nickel-titanium when preparing curved root canals. A total of 100 root canals in extracted human teeth (angles of curvatures 20°–30...

(This article belongs to the Special Issue Endodontics)
  • Systematic Review
  • Open Access
8 Citations
2,665 Views
49 Pages

Effect of Endodontic Irrigants on the Cyclic Fatigue Resistance of Nickel–Titanium Rotary Instruments: A Systematic Review

  • Bartłomiej Karaś,
  • Agnieszka Kotela,
  • Marzena Laszczyńska,
  • Zuzanna Majchrzak and ,
  • Mateusz Trafalski,
  • Jacek Matys and
  • Maciej Dobrzyński
  • + 2 authors+ 0 author

29 August 2025

Instrument fracture during endodontic treatment significantly compromises treatment outcomes, with sodium hypochlorite (NaOCl) and other irrigants potentially affecting the cyclic fatigue resistance of nickel–titanium (NiTi) rotary files. This...

(This article belongs to the Special Issue Biomechanical and Metallurgical Behavior of Endodontic and Restorative Materials)
  • Article
  • Open Access
1,613 Views
12 Pages

Impact of Downward Load and Rotational Kinematics on Root Canal Instrumentation with a Heat-Treated Nickel–Titanium Rotary Instrument

  • Risako Yamamoto,
  • Keiichiro Maki,
  • Shunsuke Kimura,
  • Satoshi Omori and ,
  • Keiko Hirano,
  • Arata Ebihara,
  • Yoshio Yahata and
  • Takashi Okiji
  • + 3 authors+ 0 author

28 December 2025

This study analyzed how different downward loads and rotational kinematics influence NiTi rotary instrumentation outcomes. Heat-treated NiTi instruments were used to prepare extracted human single-rooted premolars with a moderate canal curvature. Ins...

(This article belongs to the Topic Advances in Dental Materials)
  • Article
  • Open Access
3 Citations
1,814 Views
12 Pages

31 December 2024

The optimal amplitude of pecking motion during nickel–titanium rotary root canal instrumentation remains unclear. This study evaluated how different pecking amplitudes influence the force/torque generation, canal-centering ability, and cyclic f...

(This article belongs to the Special Issue Advanced Dental Materials and Its Applications)
  • Communication
  • Open Access
12 Citations
2,959 Views
14 Pages

6 February 2023

Background: To evaluate the cyclic fatigue resistance of rotary endodontic nickel-titanium instruments using both experimental and finite element methods. Methodology: Four different proprietary rotary endodontic instruments (PTG, PTU, VB, and TRN) w...

(This article belongs to the Special Issue Innovative Techniques in Endodontics)
  • Article
  • Open Access
127 Views
14 Pages

13 October 2026

Background: The aim of this in vitro study was to compare the cyclic fatigue resistance and fractured fragment length of three nickel-titanium (NiTi) rotary systems of identical tip size and taper (25/.06). NiTi rotary instruments fracture unpredicta...

  • Article
  • Open Access
683 Views
11 Pages

Effect of Different Downward Loads and Rotational Speeds on the Removal of Gutta-Percha and Root Canal Sealer Using a Nickel-Titanium Rotary Gutta-Percha Removal System: An Ex Vivo Study

  • Koki Toyoda,
  • Shunsuke Kimura,
  • Keiichiro Maki,
  • Satoshi Omori and ,
  • Keiko Hirano,
  • Arata Ebihara and
  • Takashi Okiji
  • + 2 authors+ 0 author

31 December 2025

Effective gutta-percha/sealer removal is essential for predictable nonsurgical endodontic retreatment, but the effects of key operational parameters on nickel–titanium rotary removal instruments remain insufficiently understood. This study aime...

(This article belongs to the Special Issue Recent Developments in Endodontics and Dental Materials)
  • Article
  • Open Access
1 Citations
997 Views
10 Pages

Effect of Clockwise Reciprocation Motion of Optimum Torque Reverse Kinematic on the Cyclic Fatigue Resistance of Nickel–Titanium Rotary Instruments with Different Metallurgical Properties

  • Jorge N. R. Martins,
  • Emmanuel J. N. L. Silva,
  • Duarte Marques,
  • João Caramês and ,
  • Francisco M. Braz Fernandes and
  • Marco A. Versiani
  • + 1 author+ 0 author

18 January 2026

This study evaluated the effect of clockwise reciprocation motion used in the original Optimum Torque Reverse kinematics, compared with clockwise continuous rotation, on the cyclic fatigue strength of nickel–titanium rotary instruments (NiTi) w...

(This article belongs to the Special Issue Novel Dental Materials Design and Application)
  • Article
  • Open Access
23 Citations
3,724 Views
11 Pages

Angle of Insertion and Torsional Resistance of Nickel–Titanium Rotary Instruments

  • Dario Di Nardo,
  • Alessio Zanza,
  • Marco Seracchiani,
  • Orlando Donfrancesco and ,
  • Gianluca Gambarini and
  • Luca Testarelli
  • + 1 author+ 0 author

4 July 2021

Previously published studies have investigated the influence of instrument access on cyclic fatigue resistance. However, no studies have evaluated the relationship between angulated access and torsional resistance. The aim of this study was to invest...

(This article belongs to the Special Issue Endodontics)
  • Article
  • Open Access
4 Citations
5,641 Views
9 Pages

Assessment of Different Root Canal Preparation Techniques with Rotary Nickel-Titanium Instruments by Novice Students

  • Andreas Bartols,
  • David W. Christofzik,
  • Matthias Krummel,
  • Christian Friedrichs and ,
  • Tim Pousset,
  • Birte Größner-Schreiber and
  • Christof E. Dörfer
  • + 2 authors+ 0 author

4 September 2018

This study investigated which preparation strategy for root canals leads to the best technical preparation quality, and moreover, which is perceived to be performed best by novice students. Sixty-four students were recruited to prepare one simulated...

  • Article
  • Open Access
6 Citations
3,648 Views
10 Pages

19 February 2023

The present study aims to measure the number of cycles leading to fracture (NCF) of instruments in static and dynamic cyclic fatigue situations under body temperature in stainless steel double-curved canals. The framework was constructed to establish...

(This article belongs to the Special Issue New Trends in Endodontic Materials and Clinical Endodontics)
  • Article
  • Open Access
2 Citations
2,647 Views
13 Pages

Wear Analysis of Four Different Single-File Reciprocating Instruments before and after Four Uses in Simulated Root Canals

  • Alessio Zanza,
  • Rodolfo Reda,
  • Giuseppe Familiari,
  • Stefania Annarita Nottola and ,
  • Dario Di Nardo,
  • Luca Testarelli and
  • Orlando Donfrancesco
  • + 2 authors+ 0 author

20 June 2022

The aim of this study is to assess the surface alterations of four reciprocating instruments before and after the shaping of four resin-simulated root canals. The following four different reciprocating instruments are selected: 10 Reciproc Blue (RB25...

(This article belongs to the Section Biomedical Engineering)
  • Review
  • Open Access
40 Citations
6,115 Views
16 Pages

Metallurgical Tests in Endodontics: A Narrative Review

  • Alessio Zanza,
  • Marco Seracchiani,
  • Rodolfo Reda,
  • Gabriele Miccoli and ,
  • Luca Testarelli and
  • Dario Di Nardo
  • + 1 author+ 0 author

Since there are no reviews of the literature on this theme, the aim of this narrative review is to summarize the metallurgical tests used in endodontics, pointing out their functional use and their pros and cons and giving readers a user-friendly gui...

  • Article
  • Open Access
4 Citations
2,032 Views
18 Pages

Multimodal Evaluation of Three NiTi Rotary Systems: Clinical Simulation, Mechanical Testing, and Finite Element Analysis

  • Jesus A. Aparicio,
  • Pedro M. Mendez S,
  • Giulia Malvicini,
  • Simone Grandini and ,
  • Carlo Gaeta,
  • Ana Paula García Guerrero,
  • Kristel Lidice Miranda Robles,
  • José Aranguren and
  • Alejandro R. Pérez
  • + 4 authors+ 0 author

15 August 2025

Objectives: This study aimed to compare the clinical durability, mechanical performance, and stress behavior of three NiTi rotary systems—BlueShaper (Blue), BlueShaper Pro (Dual Wire), and BlueShaper Gold (fully gold-treated NiTi)—through...

(This article belongs to the Special Issue Endodontics and Restorative Sciences: 2nd Edition)
  • Editorial
  • Open Access
1,567 Views
4 Pages

Are the Current Research Methods Reliable for Evaluating the Mechanical Performance of NiTi Endodontic Rotary Instruments?

  • Franco Maria Di Russo,
  • Annamaria Gisario,
  • Stefano Natali,
  • Valentina Bellanova and ,
  • Chiara Leone and
  • Luca Testarelli
  • + 1 author+ 0 author

9 November 2022

Technological innovation and the modernization of manufacturing procedures have thoroughly redefined the field of nickel–titanium (NiTi) rotary and reciprocating endodontic instruments [...]

(This article belongs to the Special Issue Innovative Techniques in Endodontics)
  • Article
  • Open Access
1 Citations
533 Views
14 Pages

Effects of Sodium Hypochlorite on Corrosion Behavior and Cyclic Fatigue in Different Types of NiTi Rotary Endodontic Instruments

  • Nenad M. Stošić,
  • Jelena Z. Popović,
  • Dušan Petković,
  • Aleksandar Mitić and ,
  • Kosta Todorović,
  • Marija Nikolić,
  • Radomir Barac,
  • Antonije Stanković,
  • Milan Miljković and
  • Ana Todorović
  • + 7 authors+ 2 authors

2 July 2026

Sodium hypochlorite (NaOCl), as the most commonly used irrigant solution, offers strong antibacterial and organic tissue dissolving properties and has the potential to express a strong corrosive effect. The aim of the study was to evaluate the effect...

(This article belongs to the Special Issue Corrosion Behavior and Mechanical Properties of Metallic Materials (3rd Edition))
  • Review
  • Open Access
26 Citations
12,524 Views
13 Pages

Endodontic Rotary Files, What Should an Endodontist Know?

  • Ana-Belén Dablanca-Blanco,
  • Pablo Castelo-Baz,
  • Ramón Miguéns-Vila,
  • Pablo Álvarez-Novoa and
  • Benjamín Martín-Biedma

Clinicians should be aware of all the characteristics and capacities of the instruments that are possible to use when conducting a root canal treatment. The wide variety of nickel–titanium (Ni-Ti) rotary systems on the market and the lack of st...

(This article belongs to the Section Dentistry and Oral Health)
  • Article
  • Open Access
1,669 Views
15 Pages

Cyclic Fatigue of Rotary Versus Reciprocating Endodontic Files: An In Vitro Study of Engine-Driven Endodontic Files

  • Sverre Brun,
  • Andrine Rebni Kristoffersen,
  • Malene Nerbøberg Solsvik,
  • Marit Øilo and
  • Inge Fristad

8 April 2026

Background/Objectives: Instrument fracture remains a significant complication in endodontics. This study compared the resistance to cyclic fatigue failure between rotary and reciprocating nickel–titanium file systems, as well as differences rel...

(This article belongs to the Special Issue Endodontics: From Technique to Regeneration)
  • Article
  • Open Access
4 Citations
4,140 Views
10 Pages

Multimethod Assessment of the Cyclic Fatigue Strength of ProGlider, Edge Glide Path and R-Pilot Endodontic Instruments

  • Jorge N. R. Martins,
  • Duarte Marques,
  • Isabel Vasconcelos,
  • Sofia Arantes-Oliveira and ,
  • João Caramês and
  • Francisco Manuel Braz Fernandes
  • + 1 author+ 0 author

17 February 2022

Background: The aim of this study was to comprehensively evaluate the cyclic fatigue strength of ProGlider, Edge Glide Path, and R-Pilot instruments. Methods: Sixty-three instruments were submitted to a multimethod evaluation. Their design was analyz...

(This article belongs to the Section Dental Materials)
  • Article
  • Open Access
6 Citations
2,565 Views
11 Pages

Comprehensive Assessment of Cyclic Fatigue Strength in Five Multiple-File Nickel–Titanium Endodontic Systems

  • Jorge N. R. Martins,
  • Emmanuel J. N. L. Silva,
  • Duarte Marques,
  • Francisco M. Braz Fernandes and
  • Marco A. Versiani

15 May 2024

The resistance of nickel–titanium endodontic instruments against cyclic fatigue failure remains a significant concern in clinical settings. This study aimed to assess the cyclic fatigue strength of five nickel–titanium rotary systems, whi...

(This article belongs to the Special Issue Corrosion, Fatigue and Corrosion Protection of Metals and Their Alloys in Various Environments)
  • Article
  • Open Access
37 Citations
7,414 Views
14 Pages

Design, Metallurgical Features, and Mechanical Behaviour of NiTi Endodontic Instruments from Five Different Heat-Treated Rotary Systems

  • Jorge N. R. Martins,
  • Emmanuel J. N. L. Silva,
  • Duarte Marques,
  • Mário Rito Pereira and ,
  • Victor T. L. Vieira,
  • Sofia Arantes-Oliveira,
  • Rui F. Martins,
  • Francisco Braz Fernandes and
  • Marco Versiani
  • + 4 authors+ 0 author

28 January 2022

The current study aimed to compare the F1 endodontic instruments from five different heat-treated rotary systems regarding their design, metallurgical properties, and mechanical performance. Five F1 root canal shaping instruments (ProTaper Gold [PTG]...

(This article belongs to the Special Issue Advances and Applications of Nickel-Titanium Alloys in Medical Fields)
  • Systematic Review
  • Open Access
27 Citations
8,949 Views
19 Pages

Cyclic Fatigue Resistance of Rotary versus Reciprocating Endodontic Files: A Systematic Review and Meta-Analysis

  • Ana De Pedro-Muñoz,
  • Cristina Rico-Romano,
  • Patricia Sánchez-Llobet,
  • José María Montiel-Company and
  • Jesús Mena-Álvarez

2 February 2024

(1) Background: The failure of nickel–titanium (NiTi) rotary files is a complication related to endodontic instruments. The aim of this study was to compare the resistance to cyclic fatigue between rotary and reciprocating file systems. (2) Met...

(This article belongs to the Section Dentistry, Oral Surgery and Oral Medicine)
  • Article
  • Open Access
8 Citations
3,391 Views
15 Pages

24 November 2022

This study aimed to evaluate and compare the effects of ambient temperature and post-manufacture heat-treatment on the mechanical behavior of nickel-titanium (NiTi) wires. Four types of commercial NiTi variants (Stock NiTi, heat treated “Blue&r...

(This article belongs to the Special Issue Advances and Applications of Nickel-Titanium Alloys in Medical Fields)
  • Article
  • Open Access
15 Citations
3,452 Views
12 Pages

Mechanical Properties and Root Canal Shaping Ability of a Nickel–Titanium Rotary System for Minimally Invasive Endodontic Treatment: A Comparative In Vitro Study

  • Hayate Unno,
  • Arata Ebihara,
  • Keiko Hirano,
  • Yuka Kasuga and ,
  • Satoshi Omori,
  • Taro Nakatsukasa,
  • Shunsuke Kimura,
  • Keiichiro Maki and
  • Takashi Okiji
  • + 4 authors+ 0 author

9 November 2022

Selection of an appropriate nickel–titanium (NiTi) rotary system is important for minimally invasive endodontic treatment, which aims to preserve as much root canal dentin as possible. This study aimed to evaluate selected mechanical properties...

(This article belongs to the Special Issue Advanced Materials and Technologies in Endodontics and Restorative Dentistry)
  • Article
  • Open Access
58 Citations
5,648 Views
8 Pages

Role of the Flat-Designed Surface in Improving the Cyclic Fatigue Resistance of Endodontic NiTi Rotary Instruments

  • Gianluca Gambarini,
  • Gabriele Miccoli,
  • Marco Seracchiani,
  • Tatyana Khrenova and ,
  • Orlando Donfrancesco,
  • Maurilio D’Angelo,
  • Massimo Galli,
  • Dario Di Nardo and
  • Luca Testarelli
  • + 4 authors+ 0 author

8 August 2019

The aim of this study was to investigate the role of the flat-designed surface in improving the resistance to cyclic fatigue by comparing heat-treated F-One (Fanta Dental, Shanghai, China) nickel–titanium (NiTi) rotary instruments and similar p...

(This article belongs to the Special Issue Current and Future Trends in Dental Materials)
  • Article
  • Open Access
18 Citations
6,343 Views
14 Pages

The Effect of Taper and Apical Diameter on the Cyclic Fatigue Resistance of Rotary Endodontic Files Using an Experimental Electronic Device

  • Vicente Faus-Llácer,
  • Nirmine Hamoud Kharrat,
  • Celia Ruiz-Sánchez,
  • Ignacio Faus-Matoses and ,
  • Álvaro Zubizarreta-Macho and
  • Vicente Faus-Matoses
  • + 1 author+ 0 author

18 January 2021

The aim of this study was to analyze the effect of the taper and apical diameter of nickel–titanium (NiTi) endodontic rotary files on the dynamic cyclic fatigue resistance. A total of 50 unused conventional NiTi wire alloy endodontic rotary ins...

(This article belongs to the Special Issue Advance of the Mechanical Properties of Dental Materials)
  • Article
  • Open Access
11 Citations
3,244 Views
8 Pages

In Vitro Analysis of the Fatigue Resistance of Four Single File Canal Preparation Instruments

  • Mohammad I. Al-Obaida,
  • Abdulmohsen A. Alzuwayer,
  • Saqer S. Alanazi and
  • Abdulrahman A. Balhaddad

17 January 2022

Instrument separation during root canal therapy is inevitable in endodontics with several unfavorable clinical consequences. Therefore, examining the cyclic flexural fatigue resistance of commonly used rotary endodontic files is crucial. This study a...

(This article belongs to the Special Issue Mechanics, Fatigue and Fracture of Metallic Materials)
  • Article
  • Open Access
11 Citations
5,052 Views
7 Pages

Effective Establishment of Glide-Path to Reduce Torsional Stress during Nickel-Titanium Rotary Instrumentation

  • Ibrahim H. Abu-Tahun,
  • Sang Won Kwak,
  • Jung-Hong Ha,
  • Asgeir Sigurdsson and ,
  • Mehmet Baybora Kayahan and
  • Hyeon-Cheol Kim
  • + 1 author+ 0 author

5 February 2019

This study compared the torque generation during canal shaping with a nickel-titanium endodontic instrument according to the extent of glide-path establishment. Seventy-five simulated S-shaped canal blocks were divided into five groups (n = 15) accor...

(This article belongs to the Special Issue Contemporary Endodontic Materials)
  • Article
  • Open Access
14 Citations
2,961 Views
6 Pages

A New Device to Test the Bending Resistance of Mechanical Endodontic Instruments

  • Gabriele Miccoli,
  • Andrea Cicconetti,
  • Gianluca Gambarini,
  • Andrea Del Giudice and ,
  • Federico Ripanti,
  • Dario Di Nardo,
  • Luca Testarelli and
  • Marco Seracchiani
  • + 3 authors+ 0 author

16 October 2020

The aims of the present study were to propose a new machine for testing the bending behavior of an instrument at multiple specific points along the cutting surface and to compare the influence of proprietary heat treatment on the bending ability of E...

(This article belongs to the Special Issue Innovative Techniques in Endodontics)
  • Article
  • Open Access
12 Citations
5,140 Views
13 Pages

28 September 2021

Current improvements in nickel-titanium (Ni-Ti) rotary file systems have created a paradigm shift in the root canal therapy of primary teeth. Therefore, it is necessary to perform a comprehensive evaluation regarding the efficiencies of newly manufac...

(This article belongs to the Special Issue Imaging Techniques for Oral and Dental Applications)
  • Article
  • Open Access
12 Citations
2,913 Views
10 Pages

Torsional Resistance of Heat-Treated Nickel-Titanium Instruments under Different Temperature Conditions

  • Hyo Jin Jo,
  • Sang Won Kwak,
  • Hyeon-Cheol Kim,
  • Sung Kyo Kim and
  • Jung-Hong Ha

14 September 2021

This study compared the torsional resistance of heat-treated nickel-titanium (NiTi) instruments under different temperature conditions. Four thermomechanically treated single-use NiTi rotary instruments were selected for this study: OneShape (OS), On...

(This article belongs to the Special Issue Contemporary Endodontic Materials)
  • Article
  • Open Access
16 Citations
8,683 Views
11 Pages

Cleaning Effectiveness of Three NiTi Rotary Instruments: A Focus on Biomaterial Properties

  • Claudio Poggio,
  • Alberto Dagna,
  • Marco Chiesa,
  • Riccardo Beltrami and
  • Stefano Bianchi

16 February 2015

Nickel-titanium (NiTi) instruments are commonly used for shaping the root canal system in endodontic practice. They are more flexible and have better cutting efficiency than conventional stainless steel files. The superelasticity of NiTi rotary files...

(This article belongs to the Special Issue Biomedical Applications of Shape Memory Alloys)
  • Article
  • Open Access
10 Citations
2,675 Views
9 Pages

4 December 2020

Objectives: This study aimed to compare the ex vivo performance of two rotary nickel–titanium (NiTi) systems with similar designs but manufactured from martensitic and austenitic alloys, the One Curve (OC) and One Shape (OS) rotary endodontic f...

(This article belongs to the Special Issue Advanced Materials for Restorative Dental Sciences)
  • Review
  • Open Access
10 Citations
9,251 Views
24 Pages

Glide Path in Endodontics: A Literature Review of Current Knowledge

  • Vlad Mircea Lup,
  • Giulia Malvicini,
  • Carlo Gaeta,
  • Simone Grandini and
  • Gabriela Ciavoi

14 August 2024

The introduction of nickel–titanium rotary instruments revolutionized shaping procedures as they were able to produce a well-tapered preparation while reducing operator fatigue. The major drawback of rotary instruments was the high risk of frac...

(This article belongs to the Special Issue Feature Papers to Celebrate the First Impact Factor of Dentistry Journal)
  • Review
  • Open Access
32 Citations
6,361 Views
10 Pages

Torque Generation of the Endodontic Instruments: A Narrative Review

  • Sang Won Kwak,
  • Ya Shen,
  • He Liu,
  • Hyeon-Cheol Kim and
  • Markus Haapasalo

17 January 2022

As the use of nickel-titanium (NiTi) file systems for root canal therapy has become popular; hence, knowledge and understanding of the characteristics of NiTi files is essential for dentists. Unintended sudden fracture can occur during root canal sha...

(This article belongs to the Special Issue Endodontics)
  • Article
  • Open Access
9 Citations
1,575 Views
12 Pages

Comparison of Four Ni-Ti Rotary Systems: Dental Students’ Perceptions in a Multi-Center Simulated Study

  • Francesco Puleio,
  • Vincenzo Tosco,
  • Riccardo Monterubbianesi,
  • Rosario Pirri and ,
  • Angela Alibrandi,
  • Daria Pulvirenti and
  • Michele Simeone
  • + 2 authors+ 0 author

24 February 2025

Background/Objectives: Nickel–titanium (Ni-Ti) rotary instruments have significantly enhanced the efficiency and safety of root canal shaping. However, the variety of Ni-Ti systems, characterized by differences in alloy composition, taper desig...

(This article belongs to the Special Issue Dental Education: Innovation and Challenge)
  • Article
  • Open Access
22 Citations
3,976 Views
9 Pages

Evaluation of Pressure Distribution against Root Canal Walls of NiTi Rotary Instruments by Finite Element Analysis

  • Giorgia Carpegna,
  • Mario Alovisi,
  • Davide Salvatore Paolino,
  • Andrea Marchetti and ,
  • Umberto Gibello,
  • Nicola Scotti,
  • Damiano Pasqualini,
  • Alessandro Scattina,
  • Giorgio Chiandussi and
  • Elio Berutti
  • + 5 authors+ 0 author

24 April 2020

The aim of this study was to evaluate the contact pressure distribution of two different nickel-titanium (NiTi) endodontic rotary instruments against the root canal walls and to virtually predict their centering ability during shaping with finite ele...

(This article belongs to the Section Applied Dentistry and Oral Sciences)
  • Article
  • Open Access
8 Citations
3,393 Views
16 Pages

A Comparative Analysis of ProTaper Ultimate and Five Multifile Systems: Design, Metallurgy, and Mechanical Performance

  • Jorge N. R. Martins,
  • Emmanuel João Nogueira Leal Silva,
  • Victor Talarico Leal Vieira,
  • Rui Pereira da Costa and ,
  • Abayomi O. Baruwa,
  • Francisco Manuel Braz Fernandes and
  • Marco Aurélio Versiani
  • + 2 authors+ 0 author

13 March 2025

The present research compared the design, metallurgical properties, and mechanical characteristics of the ProTaper Ultimate instruments with five multifile systems. A total of 469 new nickel–titanium rotary finishing instruments, all 25 mm in l...

(This article belongs to the Special Issue Development and Research of New Dental Materials)
  • Article
  • Open Access
817 Views
13 Pages

Effects of Three Types of Movements of Nickel–Titanium Instruments on Root Canal Preparation: Analysis by Using Cone-Beam Computed Tomography

  • Kinga Kaczor-Wiankowska,
  • Maciej Czechowski,
  • Philipp Arndt,
  • Aleksandra Joanna Wiankowska and ,
  • Weronika Kwiecień and
  • Katarzyna Lewusz-Butkiewicz
  • + 1 author+ 0 author

1 December 2025

The development of endodontics leads to increasingly innovative techniques, which improve mechanical root canal preparation. Endostar E3 Azure (Poldent Co., Warsaw, Poland) is a nickel–titanium file, which can be used in rotary, reciprocal, and...

(This article belongs to the Special Issue Biomechanical and Metallurgical Behavior of Endodontic and Restorative Materials)
  • Article
  • Open Access
20 Citations
2,996 Views
8 Pages

Evaluation of the Cyclic Fatigue of Two Single Files at Body and Room Temperature with Different Radii of Curvature

  • Giusy Rita Maria La Rosa,
  • Valeria Shumakova,
  • Gaetano Isola,
  • Francesco Indelicato and ,
  • Calogero Bugea and
  • Eugenio Pedullà
  • + 1 author+ 0 author

27 April 2021

Background: To compare the influence of different temperatures and curvature radii on the cyclic fatigue resistance of F6 SkyTaper (F6ST) and One Curve (OC) single file nickel-titanium rotary instruments. Methods: A total of 120 instruments of F6ST a...

(This article belongs to the Special Issue Endodontics)
  • Article
  • Open Access
8 Citations
2,854 Views
9 Pages

Effect of Different Downward Loads on Canal Centering Ability, Vertical Force, and Torque Generation during Nickel–Titanium Rotary Instrumentation

  • Keiichiro Maki,
  • Arata Ebihara,
  • Hayate Unno,
  • Satoshi Omori and ,
  • Taro Nakatsukasa,
  • Shunsuke Kimura and
  • Takashi Okiji
  • + 2 authors+ 0 author

7 April 2022

This study aimed to examine how downward loads influence the torque/force and shaping outcome of ProTaper NEXT (PTN) rotary instrumentation. PTN X1, X2, and X3 were used to prepare J-shaped resin canals employing a load-controlled automated instrumen...

(This article belongs to the Special Issue Endodontics)
  • Article
  • Open Access
6 Citations
6,637 Views
11 Pages

Influence of Coronal Flaring on the Shaping Ability of Two Heat-Treated Nickel-Titanium Endodontic Files: A Micro-Computed Tomographic Study

  • Nadine Hawi,
  • Eugenio Pedullà,
  • Giusy Rita Maria La Rosa,
  • Gianluca Conte and ,
  • Walid Nehme and
  • Prasanna Neelakantan
  • + 1 author+ 0 author

2 January 2023

Nickel-titanium (NiTi) usage is associated in endodontics with some complications including canal transportation. Centering ability of a NiTi file is the ability to stay centered in the root canal system during instrumentation. Any undesirable deviat...

(This article belongs to the Special Issue Current Topics in Endodontics)

of 2