Skip to Content

19 Results Found

  • Article
  • Open Access
1 Citations
1,474 Views
19 Pages

This research investigated the feasibility of 3D-printed external fixator (EF) rings made from carbon fiber reinforced polyamide 6 (PA6-CF) as an alternative to the conventional metallic counterpart. The study integrated tensile testing with digital...

  • Article
  • Open Access
39 Citations
6,078 Views
16 Pages

Biomechanical Comparison of Five Fixation Techniques for Unstable Fragility Fractures of the Pelvic Ring

  • Moritz F. Lodde,
  • J. Christoph Katthagen,
  • Clemens O. Schopper,
  • Ivan Zderic and ,
  • Geoff Richards,
  • Boyko Gueorguiev,
  • Michael J. Raschke and
  • René Hartensuer
  • + 3 authors+ 0 author

26 May 2021

Background: Incidence of pelvic ring fractures has increased over the past four decades, especially after low-impact trauma—classified as fragility fractures of the pelvis (FFP). To date, there is a lack of biomechanical evidence for the superiority...

(This article belongs to the Collection Pelvic Instability: Currents Insights)
  • Article
  • Open Access

Complications of Circular Ring External Fixation of the Foot and Ankle

  • Cody D. Blazek,
  • Nicholas S. Powers,
  • Paul R. Leatham and
  • Patrick R. Burns

Background: Circular ring external fixation has been found to be successful in the treatment of a wide range of foot and ankle pathologies, particularly in patients with multiple comorbidities and soft-tissue compromise, but the procedures are techni...

  • Article
  • Open Access
9 Citations
4,789 Views
14 Pages

24 August 2021

Computed tomography (CT) is an essential tool in orthopedic surgery but is known to be a method with that entails radiation exposure. CT increases the risk of developing fatal cancer, which should not be underestimated. However, patients with bone de...

(This article belongs to the Special Issue Deformity Correction, Bone Lengthening and Correction Osteotomies of the Lower Limb)
  • Article
  • Open Access
10 Citations
147 Views

From January 1995 to December 2000, 87 patients at a single medical center underwent triple arthrodesis using external rings and arched-wire compression as the method of fixation. A retrospective evaluation was conducted to assess the clinical result...

  • Article
  • Open Access

To the Editor: I am writing with regard to an article published in the January/February 2004 issue of the Journal entitled “Triple Arthrodesis Using External Ring Fixation and Arched-Wire Compression: An Evaluation of 87 Patients” by Leonard M. Talar...

  • Article
  • Open Access
823 Views
13 Pages

The Pelvic INFIX Technique for Unstable Anterior Pelvic Ring Fractures: Clinical Outcomes, Radiographic Results, and Complications

  • Vasileios Athanasiou,
  • Michail Kroustalakis,
  • Fotios Panagopoulos,
  • Panagiotis Antzoulas and ,
  • Vasileios Papathanidis and
  • Vasileios Giannatos
  • + 1 author+ 0 author

13 June 2026

Background: Unstable pelvic ring injuries often require surgical stabilization to restore pelvic ring integrity. The anterior subcutaneous internal fixator, or pelvic INFIX, has emerged as an alternative to external fixation and open anterior fixatio...

(This article belongs to the Special Issue Advances in Trauma and Orthopedic Surgery: 3rd Edition)
  • Article
  • Open Access
2 Citations
1,960 Views
25 Pages

5 April 2025

This study evaluates the feasibility of 3D-printed polymer composite external fixator (EF) rings as a cost-effective alternative to stainless steel fixators, focusing on hybrid fixators for complex tibial fractures. Mechanical performance was assesse...

(This article belongs to the Section Additive Manufacturing Technologies)
  • Article
  • Open Access

Optimal Timing and Duration of Flap-Frame Immobilization: A Podoplastic Case Series

  • Craig J. Verdin,
  • Holly D. Shan,
  • Thomas Milisits,
  • Karen K. Evans and ,
  • Christopher E. Attinger,
  • John S. Steinberg and
  • Jayson N. Atves
  • + 2 authors+ 0 author

1 September 2025

Background: Flap-based and podoplastic limb salvage in the foot and ankle is difficult due to the presence of biomechanical forces that can impact flap healing and complication rates and, in turn, limb salvage rates. For this reason, external fixatio...

  • Article
  • Open Access
19 Citations
6,292 Views
12 Pages

Does Cement Augmentation of the Sacroiliac Screw Lead to Superior Biomechanical Results for Fixation of the Posterior Pelvic Ring? A Biomechanical Study

  • Moritz F. Lodde,
  • J. Christoph Katthagen,
  • Clemens O. Schopper,
  • Ivan Zderic and ,
  • R. Geoff Richards,
  • Boyko Gueorguiev,
  • Michael J. Raschke and
  • René Hartensuer
  • + 3 authors+ 0 author

16 December 2021

Background and Objectives: The stability of the pelvic ring mainly depends on the integrity of its posterior part. Percutaneous sacroiliac (SI) screws are widely implanted as standard of care treatment. The main risk factors for their fixation failur...

(This article belongs to the Special Issue Treatment of Spine and Pelvic Fractures in Patients with Osteoporosis)
  • Communication
  • Open Access
1 Citations
4,062 Views
14 Pages

Circular SAW Resonators: Influence of Sensitive Element Dimensions on Strength Characteristics and First Experimental Samples

  • Sergey Yu. Shevchenko,
  • Denis A. Mikhailenko,
  • Alexander S. Kukaev and
  • Vladimir Yu. Venediktov

15 July 2024

In preceding research endeavors, the frequency characteristics of a ring resonator on surface acoustic waves made of various materials were studied. Investigations encompassed fixation techniques within the housing, the impact of external variables o...

(This article belongs to the Section Intelligent Sensors)
  • Article
  • Open Access
2 Citations
155 Views

Limb salvage for Charcot's neuroarthropathy has been shown to have high complication and failure rates. The aim of our report of two cases it to present a unique complication encountered with staged limb salvage for Charcot's neuroarthropathy. In two...

  • Article
  • Open Access
4 Citations
2,570 Views
11 Pages

Radiostereometric Analysis Allows Assessment of the Stability and Inducible Displacement of Pelvic Ring Disruptions during Healing: A Case Series

  • Andreas Ladurner,
  • Stuart A. Callary,
  • Aniruddha Mitra,
  • Mark Rickman and ,
  • Dominic Thewlis and
  • Lucian B. Solomon
  • + 1 author+ 0 author

24 October 2020

There is currently no accurate data on fracture displacement during the rehabilitation of pelvic ring injuries. This study investigated the use of radiostereometric analysis (RSA) in assessing the stability of C1 pelvic ring injuries stabilised with...

(This article belongs to the Section Orthopedics)
  • Article
  • Open Access
1,330 Views
19 Pages

Stand-Alone Sacroiliac-Joint Fusion as Novel Treatment Approach for Septic Arthritis of the Pubic Symphysis

  • Franz-Joseph Dally,
  • Maria Antonia Rupp Pardos,
  • Ali Darwich,
  • Sascha Gravius and ,
  • Michael Hackl,
  • Steffen Heinrich Schulz and
  • Frederic Bludau
  • + 2 authors+ 0 author

2 February 2026

Management of septic arthritis of the pubic symphysis (SAS) presents with substantial clinical challenges. Firstly, the SAS is an extremely rare entity. Surgical resection of the symphysis plus targeted antibiotic therapy is a widely adopted treatmen...

(This article belongs to the Section Surgery)
  • Protocol
  • Open Access
6 Citations
5,067 Views
14 Pages

Establishment of a Novel Method for Spinal Discectomy Surgery in Elderly Rats in an In Vivo Spinal Fusion Model

  • Katharina A. C. Oswald,
  • Sebastian F. Bigdon,
  • Andreas S. Croft,
  • Paola Bermudez-Lekerika and ,
  • Alessandra Bergadano,
  • Benjamin Gantenbein and
  • Christoph E. Albers
  • + 2 authors+ 0 author

2 November 2021

The rat model is a common model for intervertebral disc (IVD) and spinal research. However, complications remain challenging. Standard Operating Procedures (SOPs) are validated methods to minimize complications and improve safety and quality of studi...

(This article belongs to the Section Biomedical Sciences and Physiology)
  • Article
  • Open Access
1 Citations
7,103 Views
12 Pages

3 March 2023

Background: Congenital pseudoarthrosis of the tibia (CPT) remains a challenge for physicians. Several treatment options have been proposed, but the standard of care remains inconclusive. In this study, we present three patients for whom the failure o...

(This article belongs to the Special Issue Pediatric Fractures—Volume II)
  • Article
  • Open Access
1 Citations
426 Views

Background: Charcot’s neuroarthropathy (CN) is a destructive inflammatory process that affects patients with peripheral neuropathy, most commonly those with uncontrolled diabetes mellitus. The disease progresses through an active hyperemic phase that...

  • Case Report
  • Open Access
3 Citations
3,479 Views
7 Pages

Clinical and Biomechanical Progression after Ankle Joint Distraction in a Young Adolescent Patient with Haemophilia

  • Nicolas Haelewijn,
  • Sebastien Lobet,
  • An Van Damme,
  • Pierre-Louis Docquier and ,
  • Maarten Eerdekens and
  • Kevin Deschamps
  • + 1 author+ 0 author

Ankle joint distraction (AJD) has been described to be a valuable joint-sparing alternative to arthrodesis or arthroplasty; however, clinical endpoints associated to this surgical intervention are lacking. The current case report describes clinical a...

(This article belongs to the Special Issue Advances in Foot Posture Assessment and Health Implications)
  • Article
  • Open Access
10 Citations
4,116 Views
18 Pages

3 June 2020

Due to the brittle nature of poly(lactic acid) many attempts have been made to flexibilize this polyester for applications such as thin films and foils. However, due to complex phase behavior, many drawbacks for plasticizer and blend components are d...

(This article belongs to the Special Issue Biobased Polymers)