Skip Content
You are currently on the new version of our website. Access the old version .

439 Results Found

  • Article
  • Open Access
4 Citations
6,001 Views
18 Pages

9 March 2016

This paper addresses the grid-connected variable speed doubly-fed induction generator, and proposes a new decoupled control to replace the conventional decoupled active and reactive powers (P-Q) control. The proposed decoupled control is based on dec...

  • Article
  • Open Access
7 Citations
2,220 Views
13 Pages

Low Sensitivity Predictive Control for Doubly-Fed Induction Generators Based Wind Turbine Applications

  • Mohamed Abdelrahem,
  • Christoph Hackl,
  • Ralph Kennel and
  • Jose Rodriguez

16 August 2021

In this paper, a deadbeat predictive control (DBPC) technique for doubly-fed induction generators (DFIGs) in wind turbine applications is proposed. The major features of DBPC scheme are its quick dynamic performance and its fixed switching frequency....

  • Article
  • Open Access
12 Citations
4,056 Views
12 Pages

21 February 2019

Wind energy integration in power grids is increasing day by day to reduce the use of fossil fuels, and consequently greenhouse gas emissions. Using the pulse-width modulated (PWM) power converters in wind turbine generators, specifically in doubly-fe...

  • Article
  • Open Access
883 Views
15 Pages

Ultra-Low Frequency Oscillation in a Thermal Power System Induced by Doubly-Fed Induction Generators with Inertia Control

  • Wei Huang,
  • Suwei Zhai,
  • Xuegang Lu,
  • Xiaojie Zhang,
  • Yanjun Liu,
  • Wei He and
  • Yifan Fang

29 April 2025

Ultra-low frequency oscillation has been regarded as a typical instability issue in power systems consisting of hydro turbine synchronous generators due to the water hammer phenomenon. However, the increasing installation of renewable power generator...

  • Article
  • Open Access
2 Citations
2,583 Views
18 Pages

1 October 2018

Harmonic amplification for doubly-fed induction generator wind turbine systems (DFIG WTSs) will occur due to the existence of non-linear loads and reactive power compensation installation, and grid voltage and total grid current at the point of commo...

  • Article
  • Open Access
3 Citations
2,961 Views
41 Pages

12 August 2020

Wind energy conversion systems (WECSs) seem certain to play a major part in the world’s energy future due to their known high power capacity. The maximum power tracking is unavoidable due to the wind velocity variation and the non-linear relati...

  • Article
  • Open Access
57 Citations
15,565 Views
16 Pages

Crowbar System in Doubly Fed Induction Wind Generators

  • Maurício B. C. Salles,
  • Kay Hameyer,
  • José R. Cardoso,
  • Ahda. P. Grilo and
  • Claudia Rahmann

12 April 2010

In the last 15 years, the use of doubly fed induction machines in modern variable-speed wind turbines has increased rapidly. This development has been driven by the cost reduction as well as the low-loss generation of Insulated Gate Bipolar Transisto...

  • Feature Paper
  • Review
  • Open Access
35 Citations
6,231 Views
24 Pages

25 October 2018

The doubly-fed induction generator has significant features compared to the fixed speed wind turbine, which has popularised its application in power systems. Due to partial rated back-to-back converters in the doubly-fed induction generator, fault ri...

  • Article
  • Open Access
7 Citations
4,340 Views
15 Pages

23 December 2018

Large-scale wind farms connect to the grid and deliver electrical energy to the load center. When a short-circuit fault occurs on the transmission line, there will be an excess of electric power, but the power demand will increase instantaneously onc...

  • Article
  • Open Access
8 Citations
3,001 Views
24 Pages

14 July 2019

Wind turbines can participate in frequency regulation by controlling active power output, but the indeterminacy and volatility of wind power result in low reliability of frequency support. Therefore, as a kind of energy storage system, an electric ve...

  • Article
  • Open Access
7 Citations
2,958 Views
17 Pages

To solve the problem of incompatibility and mutual repulsion between a distribution network (DN) and distributed generation (DG), this paper first analyzes the conflicts between current feeder automation (FA) and doubly-fed induction generation (DFIG...

  • Article
  • Open Access
106 Views
15 Pages

17 January 2026

The anti-load-disturbance capability is one of the most important capabilities in a microgrid. In comparison with the grid-connected brushless doubly-fed induction generator (BDFIG), the output voltage of the standalone BDFIG in a microgrid is more s...

  • Article
  • Open Access
10 Citations
2,894 Views
15 Pages

29 November 2021

Doubly-fed induction generators (DFIGs) participate in the system frequency regulation using a fixed-coefficient droop control scheme. Nevertheless, the frequency-supporting capability of this control scheme with fixed gain is limited for different d...

  • Article
  • Open Access
2 Citations
1,424 Views
20 Pages

High-Resistance Connection Diagnosis of Doubly Fed Induction Generators

  • Wei Ding,
  • Yulong Jin,
  • Xijin Wu,
  • Yufeng Yang and
  • Yongjiang Jiang

9 November 2023

The high resistance connection fault of the stator is a common fault in doubly fed induction generators, which causes a three-phase imbalance in the stator circuit. Since the stator winding is directly connected to the power grid, interference from t...

  • Article
  • Open Access
6 Citations
3,439 Views
21 Pages

22 November 2019

The extensive connection of distributed generation (DG) with the distribution network (DN) is one of the core features of a smart grid, but in case of a large number, it may result in problems concerning the DN-DG compatibility during fault isolation...

  • Article
  • Open Access
20 Citations
12,126 Views
25 Pages

27 February 2015

This paper deals with the operational behavior of the Doubly-Fed Induction Generator Wind Energy Conversion System under power electronic converter and rotor terminals faulty conditions. More specifically, the effect of the short-circuit fault both i...

  • Article
  • Open Access
9 Citations
2,460 Views
16 Pages

9 August 2021

This paper proposes a grouped, reactive power optimization control strategy to maximize the active power output of a doubly-fed induction generator (DFIG) based on a large wind farm (WF). Optimization problems are formulated based on established grou...

  • Article
  • Open Access
26 Citations
9,161 Views
21 Pages

19 November 2012

A novel control strategy is proposed in this paper for the rotor side converter (RSC) of doubly-fed induction generator (DFIG)-based wind power generation systems. It is supposed to enhance the low-voltage ride-through (LVRT) capability of DFIGs duri...

  • Article
  • Open Access
53 Citations
8,224 Views
26 Pages

Modeling and Control Strategy of Wind Energy Conversion System with Grid-Connected Doubly-Fed Induction Generator

  • Abrar Ahmed Chhipą,
  • Prąsun Chakrabarti,
  • Vadim Bolshev,
  • Tulika Chakrabarti,
  • Gennady Samarin,
  • Alexey N. Vasilyev,
  • Sandeep Ghosh and
  • Alexander Kudryavtsev

13 September 2022

The most prominent and rapidly increasing source of electrical power generation, wind energy conversion systems (WECS), can significantly improve the situation with regard to remote communities’ power supply. The main constituting elements of a...

  • Article
  • Open Access
7 Citations
4,142 Views
18 Pages

4 July 2018

The development of a preventive control methodology to increase the capacity of voltage sag recovery (Fault Ride Through Capability (FRTC)) of a doubly-fed induction generator (DFIG) connected in an electrical network is presented. This methodology,...

  • Article
  • Open Access
3 Citations
1,363 Views
19 Pages

30 March 2024

Large-scale wind farms incorporating doubly-fed induction generators (DFIGs) are considered a promising direction for modern energy supply systems due to their role in reducing dependence on fossil energy sources. However, the dynamic interactions be...

  • Article
  • Open Access
10 Citations
1,583 Views
22 Pages

4 September 2024

The doubly-fed induction generator (DFIG) is vulnerable to overcurrent at the stator winding and overvoltage at the DC link due to voltage drop after the grid fault. The large wind farm may have a capacity of several million MWs, whose tripping yield...

  • Article
  • Open Access
463 Views
18 Pages

Identification of Control Parameters in Doubly Fed Induction Generators via Adaptive Differential Evolution

  • Jun Deng,
  • Yu Wang,
  • Yao Liu,
  • Tianyue Zheng,
  • Nan Xia,
  • Ziang Li and
  • Tong Wang

19 September 2025

With the increasing penetration of renewable energy generation, analysis of the transient characteristics of doubly fed induction generators, as the mainstream wind turbine configuration, is made highly significant both theoretically and practically....

  • Article
  • Open Access
1 Citations
2,048 Views
19 Pages

2 March 2023

Due to the rapid development of wind power, the stable operation of doubly fed induction generators (DFIGs) has attracted much attention. This paper focuses on the finite frequency (FF) H∞ control for the DFIG with input delay, aiming to reduce...

  • Article
  • Open Access
3 Citations
1,792 Views
24 Pages

Development of a 3 kW Wind Energy Conversion System Emulator Using a Grid-Connected Doubly-Fed Induction Generator

  • Boussad Boukais,
  • Koussaila Mesbah,
  • Adel Rahoui,
  • Abdelhakim Saim,
  • Azeddine Houari and
  • Mohamed Fouad Benkhoris

29 November 2024

This paper presents the design and performance evaluation of an experimental platform that emulates the static and dynamic behavior of a 3 kW Wind Energy Conversion System (WECS). The platform includes a wind turbine emulator (WTE) using a separately...

  • Review
  • Open Access
9 Citations
1,840 Views
25 Pages

31 July 2024

This paper presents a novel hybrid type-2 fuzzy sliding mode control approach for regulating active and reactive power exchanged with the utility grid by a doubly-fed induction generator in a wind energy conversion system. The main objective of this...

  • Article
  • Open Access
6 Citations
2,824 Views
20 Pages

A sub-synchronous oscillation (SSO) suppression strategy of attaching virtual resistance controllers to the rotor-side converter (RSC) of the doubly-fed induction generator (DFIG) is proposed in this study to suppress sub-synchronous oscillation (SSO...

  • Review
  • Open Access
42 Citations
6,367 Views
56 Pages

5 September 2022

Wind-driven turbines utilizing the doubly-fed induction generators aligned with the progressed IEC 61400 series standards have engrossed specific consideration as of their benefits, such as adjustable speed, consistent frequency mode of operation, se...

  • Article
  • Open Access
1,441 Views
18 Pages

The integration of wind power into a grid on a large scale results in a reduction of the system’s inertia level, causing an impact on the stability of the system frequency. Doubly fed induction generators (DFIG) can optimize active output but l...

  • Article
  • Open Access
1 Citations
1,404 Views
26 Pages

Reinforcement Learning-Based Current Compensation for Brushless Doubly Fed Induction Generators Under Transient- and Low-Voltage Ride-Through Faults

  • Muhammad Ismail Marri,
  • Najeeb Ur Rehman Malik,
  • Muhammad Masud,
  • Touqeer Ahmed Jumani,
  • Atta Ullah Khidrani and
  • Zeeshan Shahid

12 February 2025

Wind and solar energy are increasingly vital for meeting clean renewable energy needs, with Brushless Doubly Fed Induction Generators gaining popularity due to their cost efficiency and reliability. A key challenge in integrating wind energy into the...

  • Article
  • Open Access
11 Citations
5,020 Views
25 Pages

27 October 2017

Wind turbine driven doubly-fed induction generators (DFIGs) are widely used in the wind power industry. With the increasing penetration of wind farms, analysis of their effect on power systems has become a critical requirement. This paper presents th...

  • Article
  • Open Access
10 Citations
3,600 Views
12 Pages

Grid Forming Stator Flux Control of Doubly-Fed Induction Generator

  • Norbert Klaes,
  • Florian Pöschke and
  • Horst Schulte

17 October 2021

The doubly fed induction generator is widely used in wind power applications. For stand-alone operation of this machine, the control of the stator flux with fixed voltage and frequency has been proposed. This paper extends the stator flux control of...

  • Article
  • Open Access
7 Citations
4,252 Views
16 Pages

8 June 2019

Using a doubly-fed induction generator (DFIG), with an additional active or reactive damping controller, is a new method of suppressing the inter-area oscillation of a power system. However, using active power modulation (APM) may decrease the dampin...

  • Article
  • Open Access
2 Citations
2,055 Views
20 Pages

28 September 2021

A fault current limiter (FCL) may be applied to assist the low-voltage ride-through (LVRT) of a doubly fed induction generator (DFIG). FCLs with fixed impedance, lack the flexibility to adjust their impedance to adapt to different LVRT scenarios. The...

  • Article
  • Open Access
49 Citations
3,875 Views
31 Pages

11 November 2020

A second-order sliding mode (SOSM)-based direct power control (DPC) of a doubly-fed induction generator (DFIG) is introduced in this research paper. Firstly, the DFIG output powers are regulated with the developed SOSM controller-based DPC scheme. Th...

  • Article
  • Open Access
25 Citations
7,620 Views
22 Pages

9 September 2013

This paper aims to explore a viable solution for a doubly-fed induction generator (DFIG)-based wind farm to meet the reactive support requirement of the low voltage ride-through (LVRT) grid code with safe grid-connected operation during asymmetrical...

  • Article
  • Open Access
25 Citations
6,045 Views
24 Pages

18 May 2017

This paper investigates the performance of a fault-tolerant four-switch three-phase (FSTP) grid-side converter (GSC) in a doubly-fed induction generator-based wind turbine (DFIG-WT). The space vector pulse width modulation (SVPWM) technique is simpli...

  • Article
  • Open Access
6 Citations
2,152 Views
36 Pages

11 October 2022

This work presents an investigation into the use of swarm intelligence techniques for the control of the doubly fed induction generator under unbalanced grid voltages. Swarm intelligence is a concept that was introduced in the late 20th century but h...

  • Article
  • Open Access
23 Citations
2,628 Views
13 Pages

25 February 2021

This paper focuses on the performance analysis of a sensorless control for a Doubly Fed Induction Generator (DFIG) in grid-connected operation for turbine-based wind generation systems. With reference to a conventional stator flux based Field Oriente...

  • Article
  • Open Access
23 Citations
5,810 Views
23 Pages

Complementary Power Control for Doubly Fed Induction Generator-Based Tidal Stream Turbine Generation Plants

  • Khaoula Ghefiri,
  • Soufiene Bouallègue,
  • Izaskun Garrido,
  • Aitor J. Garrido and
  • Joseph Haggège

28 June 2017

The latest forecasts on the upcoming effects of climate change are leading to a change in the worldwide power production model, with governments promoting clean and renewable energies, as is the case of tidal energy. Nevertheless, it is still necessa...

  • Article
  • Open Access
20 Citations
4,499 Views
19 Pages

4 May 2018

This paper proposes a second-order active disturbance rejection control (ADRC)-based control strategy with an integrated design of the flux damping method, for the fault ride-through (FRT) improvement in wind power generation systems with a doubly-fe...

  • Article
  • Open Access
7 Citations
1,277 Views
23 Pages

12 April 2025

The inherent complexity of wind energy systems has necessitated the development of sophisticated control methodologies to optimize operational efficiency. Artificial neural networks (ANN) have emerged as a powerful tool in wind turbine applications,...

  • Article
  • Open Access
7 Citations
3,885 Views
22 Pages

2 April 2018

In this paper, a novel voltage control strategy for stand-alone operation brushless doubly fed induction generators for variable speed constant frequency wind energy conversion systems was presented and discussed. Based on the model of the power gene...

  • Article
  • Open Access
28 Citations
6,754 Views
23 Pages

20 April 2017

The potential of utilizing doubly-fed induction generator (DFIG)-based wind farms to improve power system damping performance and to enhance small signal stability has been proposed by many researchers. However, the simultaneous coordinated tuning of...

  • Article
  • Open Access
2 Citations
2,906 Views
20 Pages

16 February 2019

Wind turbines (WTs) participate in frequency regulation, which is one of the means to solve the problem of inadequate regulation capacity in power systems with a high proportion of renewable energy. The doubly fed induction generator (DFIG) can reser...

  • Article
  • Open Access
1 Citations
1,076 Views
20 Pages

Coordinated Control of Transient Voltage Support in Doubly Fed Induction Generators

  • Guanghu Xu,
  • Jian Qiu,
  • Jianxin Zhang,
  • Huanhuan Yang,
  • Qin Gao,
  • Tuo Jiang and
  • Yuan Wang

24 September 2024

The large-scale integration of wind power significantly alters the voltage dynamic characteristics of power systems. Wind turbines have a weak ability to withstand grid disturbances and have difficulty in providing effective reactive power support du...

  • Article
  • Open Access
1 Citations
2,444 Views
21 Pages

28 November 2022

For improving the zero-voltage ride through the capability of a doubly fed induction generator in high proportion new energy grid in extreme faults, a coordinated control scheme of hardware and optimal control strategy is proposed. A high-temperature...

  • Article
  • Open Access
17 Citations
4,383 Views
19 Pages

Steady State Modeling and Performance Analysis of a Wind Turbine-Based Doubly Fed Induction Generator System with Rotor Control

  • Belqasem Aljafari,
  • Jasmin Pamela Stephenraj,
  • Indragandhi Vairavasundaram and
  • Raja Singh Rassiah

3 May 2022

The utilization of renewable energy sources aids in the economic development of a country. Among the various renewable energy sources, wind energy is more effective for electricity production. The doubly fed induction generator is an extensively know...

  • Article
  • Open Access
44 Citations
2,711 Views
29 Pages

Enhancement of Direct Power Control by Using Artificial Neural Network for a Doubly Fed Induction Generator-Based WECS: An Experimental Validation

  • Hamid Chojaa,
  • Aziz Derouich,
  • Seif Eddine Chehaidia,
  • Othmane Zamzoum,
  • Mohammed Taoussi,
  • Habib Benbouhenni and
  • Said Mahfoud

9 December 2022

Direct power control (DPC) is among the most popular control schemes used in renewable energy because of its many advantages such as simplicity, ease of execution, and speed of response compared to other controls. However, this method is characterize...

  • Article
  • Open Access
3 Citations
3,560 Views
23 Pages

22 December 2017

As the phase current sensors and rotor speed/position sensor are prone to fail in the late stage of an offshore doubly-fed induction generator based wind turbine (DFIG-WT), this paper investigates a hybrid fault-tolerant strategy for a severe sensor...