Skip to Content

20 Results Found

  • Article
  • Open Access
9 Citations
4,461 Views
28 Pages

25 May 2023

The use of heat pumps is increasing worldwide, and knowledge of their properties is becoming more and more important. Although numerous tests regarding heat pumps have been performed, due to the large number of influencing variables, the entire range...

(This article belongs to the Section Environmental Sustainability and Applications)
  • Article
  • Open Access
2 Citations
1,040 Views
43 Pages

4E Analysis of Alternative Configurations in Mobile Air Conditioning Used in Electromobility and Conventional Vehicles

  • D. Méndez-Méndez,
  • J. F. Ituna-Yudonago,
  • J. J. Ramírez-Minguela,
  • J. M. Belman-Flores and
  • V. Pérez-García

22 March 2026

This study analyzes four alternative cycle configurations for the traditional vapor compression system used in conventional, hybrid, and electric vehicles, taking low-GWP alternatives for the substitution of R134a. These are cycle with an internal he...

(This article belongs to the Special Issue Novel Ecofriendly Refrigeration System: Technology and Application)
  • Article
  • Open Access
2,414 Views
17 Pages

20 August 2024

Although the R404A indirect refrigeration system (IRS) with an internal heat exchanger (IHX) and R744 as the secondary fluid has potential applications in supermarkets and hypermarkets, the exergy characteristics of this IRS have not been extensively...

(This article belongs to the Section J: Thermal Management)
  • Article
  • Open Access
1 Citations
2,726 Views
16 Pages

19 August 2024

In this study, the performance characteristics of an R404A indirect refrigeration system (IRS) applied to an internal heat exchanger (IHX) is evaluated for supermarkets and hypermarkets. In a direct expansion system, R404A is the primary refrigerant...

(This article belongs to the Section J: Thermal Management)
  • Article
  • Open Access
22 Citations
7,809 Views
14 Pages

Second Law Analysis of a Mobile Air Conditioning System with Internal Heat Exchanger Using Low GWP Refrigerants

  • Vicente Pérez-García,
  • Juan M. Belman-Flores,
  • José L. Rodríguez-Muñoz,
  • Víctor. H. Rangel-Hernández and
  • Armando Gallegos-Muñoz

19 April 2017

This paper investigates the results of a Second Law analysis applied to a mobile air conditioning system (MACs) integrated with an internal heat exchanger (IHX) by considering R152a, R1234yf and R1234ze as low global warming potential (GWP) refrigera...

(This article belongs to the Special Issue Work Availability and Exergy Analysis)
  • Article
  • Open Access
2 Citations
2,683 Views
23 Pages

21 September 2024

The cascade refrigeration systems (CRS) used in hypermarkets and supermarkets, which are used by many people, have been employing R744 for the low-temperature cycle (LTC) and R404A for the high-temperature cycle (HTC) due to environmental and public...

(This article belongs to the Section J: Thermal Management)
  • Article
  • Open Access
15 Citations
4,130 Views
24 Pages

26 May 2021

Hydrogen production is a topical issue in an energy scenario where decarbonization is a priority, especially with reference to the transport sector that has a great weight on global emissions. Starting from this consideration, GIF (Generation-IV Inte...

(This article belongs to the Special Issue Expanding Nuclear Applications and Technologies for a Clean Energy Future)
  • Article
  • Open Access
5 Citations
4,236 Views
23 Pages

6 September 2024

The R744/R404A cascade refrigeration system (CRS) has been widely used in supermarkets and hypermarkets, but due to the refrigerant regulation of R404A, research on alternative refrigerants is necessary. In addition, although there have been quite a...

(This article belongs to the Section J: Thermal Management)
  • Article
  • Open Access
30 Citations
4,903 Views
27 Pages

Experimental Analysis and Optimization of an R744 Transcritical Cycle Working with a Mechanical Subcooling System

  • Daniel Sánchez,
  • Jesús Catalán-Gil,
  • Ramón Cabello,
  • Daniel Calleja-Anta and ,
  • Rodrigo Llopis and
  • Laura Nebot-Andrés
  • + 1 author+ 0 author

19 June 2020

In the last century, the refrigerant R744 (carbon dioxide) has become an environmentally friendly solution in commercial refrigeration despite its particular issues related to the low critical temperature. The use of transcritical cycles in warm and...

(This article belongs to the Special Issue Refrigeration Systems and Applications 2020)
  • Article
  • Open Access
25 Citations
4,280 Views
14 Pages

8 April 2020

The characteristics of the transcritical CO2 heat pump water heater (HPWH) system are; a lower inlet hot water temperature (Ti-hw) (sometimes this is lower than the water source temperature), and an outlet gas cooler temperature (To-gc) which is affe...

  • Article
  • Open Access
392 Views
24 Pages

9 September 2026

This study aims to provide essential data for the optimal design of a transcritical CO2 water-cooled heat pump system utilizing an internal heat exchanger (IHX). To investigate cycle and application characteristics, a heat pump test rig consisting of...

(This article belongs to the Section J2: Thermodynamics)
  • Article
  • Open Access
9 Citations
4,208 Views
19 Pages

Internal Heat Exchanger Influence in Operational Cost and Environmental Impact of an Experimental Installation Using Low GWP Refrigerant for HVAC Conditions

  • Dario Méndez-Méndez,
  • Vicente Pérez-García,
  • Juan M. Belman-Flores,
  • José M. Riesco-Ávila and
  • Juan M. Barroso-Maldonado

16 May 2022

The use of an internal heat exchanger in vapor compression refrigeration systems of one stage is a common practice because it helps to increase the cooling capacity in the evaporator. Furthermore, the use of refrigerants with low global warming poten...

(This article belongs to the Section Air, Climate Change and Sustainability)
  • Article
  • Open Access
10 Citations
4,160 Views
16 Pages

Effects of Internal Heat Exchanger on Two-Stage Compression Trans-Critical CO2 Refrigeration Cycle Combined with Expander and Intercooling

  • Benlin Shi,
  • Muqing Chen,
  • Weikai Chi,
  • Qichao Yang and ,
  • Guangbin Liu,
  • Yuanyang Zhao and
  • Liansheng Li
  • + 2 authors+ 0 author

22 December 2022

Because of the limitations of traditional refrigerants, the application of trans-critical CO2 technology in domestic gas conditioners and other fields is becoming increasingly popular. This paper proposes a new CO2 trans-critical refrigeration system...

(This article belongs to the Section A2: Solar Energy and Photovoltaic Systems)
  • Article
  • Open Access
27 Citations
4,914 Views
18 Pages

5 July 2021

The phase-down of hydrofluorocarbons and substitution with low global warming potential values are consequences of the awareness about the environmental impacts of greenhouse gases. This theoretical study evaluated the energy and exergy performances...

(This article belongs to the Special Issue 10th Anniversary of Applied Sciences: Invited Papers in Applied Thermal Engineering)
  • Article
  • Open Access
5 Citations
2,831 Views
25 Pages

Thermodynamic Evaluation of Low-GWP A1 Refrigerants for Ultra-Low Temperature Refrigeration Applications

  • Pau Giménez-Prades,
  • Cosmin-Mihai Udroiu,
  • Joaquín Navarro-Esbrí and
  • Adrián Mota-Babiloni

20 August 2025

Slow market development has caused the lack of low-GWP A1 refrigerants for ultra-low temperature (ULT) refrigeration. Consequently, the high-GWP refrigerant R23 (GWP = 14,600) remains widely used within the ULT sector. For this reason, this paper pro...

(This article belongs to the Section J2: Thermodynamics)
  • Feature Paper
  • Article
  • Open Access
1,595 Views
16 Pages

15 August 2025

Cost-effective procedures usually cannot achieve complete removal of priority contaminants present in water at very low concentrations (as pesticides or pharmaceuticals). Advanced oxidation processes (AOPs) represent promising technologies for removi...

(This article belongs to the Special Issue Advances in Photocatalytic Degradation)
  • Article
  • Open Access
3 Citations
3,780 Views
19 Pages

Evaluation of the Use of Different Dedicated Mechanical Subcooling (DMS) Strategies in a Water Source Transcritical CO2 Heat Pump for Space Heating Applications

  • Fernando Illán-Gómez,
  • José Ramón García-Cascales,
  • Francisco Javier Sánchez-Velasco and
  • Ramón A. Otón-Martínez

17 November 2022

In this work we analyze numerically different design configurations to be used in a R1234yf DMS cycle coupled with a water source, transcritical CO2 heat pump for heating applications in the building sector. Specifically, we study the temperature ran...

(This article belongs to the Special Issue Synergistic Technologies to Advance in Sustainable Refrigeration)
  • Feature Paper
  • Article
  • Open Access
18 Citations
5,322 Views
17 Pages

Thermodynamic Analysis of a CO2 Refrigeration Cycle with Integrated Mechanical Subcooling

  • Laura Nebot-Andrés,
  • Daniel Calleja-Anta,
  • Daniel Sánchez,
  • Ramón Cabello and
  • Rodrigo Llopis

18 December 2019

Different alternatives are being studied nowadays in order to enhance the behavior of transcritical CO2 refrigeration plants. Among the most studied options, subcooling is one of the most analyzed methods in the last years, increasing cooling capacit...

(This article belongs to the Section J: Thermal Management)
  • Article
  • Open Access
12 Citations
8,047 Views
16 Pages

20 February 2023

In this paper, a new R744 heat pump system is studied. The gas cooler, evaporator, indoor heat core, and indoor gas cooler are all micro-channel heat exchangers. The R744 high pressure system adopts a combination of an accumulator and internal heat e...

(This article belongs to the Special Issue Current Status on the Thermal Management of Electric Vehicles)
  • Article
  • Open Access
2 Citations
3,361 Views
18 Pages

A New Method of Regulating the Cooling Capacity of a Cooling System with CO2

  • Artur Bieniek,
  • Jan Kuchmacz,
  • Karol Sztekler,
  • Lukasz Mika and
  • Ewelina Radomska

31 March 2021

New guidelines set by international organizations for refrigeration companies cause that natural working fluids such as carbon dioxide are increasingly used in new refrigeration systems. Carbon dioxide (R-744) is used in freezing, cooling, or air con...

(This article belongs to the Special Issue Alternative and Emerging Cooling and Heating Technologies)