Skip to Content
You are currently on the new version of our website. Access the old version .

Prosthesis, Volume 8, Issue 7

2026 July - 16 articles

Cover Story: The Mercer Universal Prosthesis (MUP®) with standardized alignment simplifies prosthetic fitting by eliminating the need for dynamic alignment while enabling immediate ambulation. This 1-year study evaluated the biomechanical and functional outcomes of 20 Vietnamese transtibial amputees. Participants completed clinical evaluations at baseline immediately after fitting, 6 months, and 12 months, including gait biomechanics, muscle activation, joint health, mobility, and quality-of-life assessments. The findings demonstrate that the MUP maintained gait performance, muscle activation patterns, mobility, and quality of life throughout the study period. Overall, the MUP represents a practical and cost-effective solution for expanding prosthetic rehabilitation in resource-limited settings and low- and middle-income countries (LMICs). View this paper
  • Issues are regarded as officially published after their release is announced to the table of contents alert mailing list .
  • You may sign up for email alerts to receive table of contents of newly released issues.
  • PDF is the official format for papers published in both, html and pdf forms. To view the papers in pdf format, click on the "PDF Full-text" link, and use the free Adobe Reader to open them.

Articles (16)

  • Review
  • Open Access
1,117 Views
19 Pages

Finite Element in Dentistry: A Review and Bibliometric Analysis

  • Luca Fiorillo,
  • Javier Flores-Fraile,
  • Attilio Caravelli,
  • Artak Heboyan and ,
  • Mario Alberto Alarcón-Sánchez,
  • Dario Milone and
  • Cosimo Galletti
  • + 2 authors+ 0 author

Background: Finite element analysis (FEA) has become a cornerstone of dental biomechanics, supporting the simulation of stress, strain, and displacement in biological structures and biomaterials. Methods: This combined bibliometric and narrative revi...

(This article belongs to the Section Prosthodontics)
  • Article
  • Open Access
643 Views
12 Pages

Background: Accurate acetabular component positioning is critical to the success of total hip arthroplasty (THA). Mixed reality (MR)-based simulation offers a novel approach to surgical training by providing real-time feedback within immersive learni...

(This article belongs to the Special Issue Current and Emerging Concepts in Personalized Arthroplasty)
  • Article
  • Open Access
1,211 Views
17 Pages

Background: The natural motion of the human knee involves a combination of rotation and translation, resulting in a variable Instantaneous Center of Rotation (ICR) throughout the gait cycle. Traditional prosthetic knee designs often fail to reproduce...

(This article belongs to the Special Issue Advances in Prosthetic Gait Analysis and Functional Mobility Restoration)
  • Article
  • Open Access
1,001 Views
13 Pages

Impingement During Dislocation-Prone Activities in Acetabular Cups with Lipped and Standard Liners: A Geometric Model

  • Mackenzie Smeeton,
  • Simon P. Williams,
  • James Anderson,
  • Ruth Wilcox and ,
  • Tim Board,
  • Sophie Williams and
  • Graham Isaac
  • + 2 authors+ 0 author

Background/Objectives: Asymmetric acetabular liners used in Total Hip Arthroplasty (THA) are clinically successful in reducing revision associated with dislocation. The performance of an asymmetric liner is dependent on its positioning, although few...

  • Article
  • Open Access
1,157 Views
19 Pages

Pain, Function, Gait, and Surface EMG After Anterior Versus Lateral Total Hip Arthroplasty: A Pilot Prospective Study

  • Raffele Iorio,
  • Massimiliano Mangone,
  • Federico Corsetti,
  • Mario Vetrano and ,
  • Gabriele Santilli,
  • Valter Santilli,
  • Giorgio Felzani,
  • Massimiliano Murgia,
  • Francesco Agostini and
  • Nicola Maffulli
  • + 6 authors+ 1 author

Background: Total hip arthroplasty (THA) is an effective treatment for advanced hip osteoarthritis, yet the influence of the surgical approach on early biomechanical and neuromuscular recovery remains debated. The direct anterior approach (DAA) is co...

  • Article
  • Open Access
1,088 Views
22 Pages

Development of an EMG-Based Movement Intention Recognition Platform for Lower-Limb Exoskeletons

  • Lilia Sava,
  • Larisa Dunai,
  • Valentina Tirsu,
  • Andrei Dorogan and ,
  • Dinu Turcanu,
  • Nelea Manin and
  • Alexandru Ilev
  • + 2 authors+ 0 author

Background/Objectives: Lower-limb exoskeletons require reliable movement recognition mechanisms to support adaptive locomotor assistance and rehabilitation. Electromyographic (EMG) signals provide valuable information on muscle activation and user in...

  • Article
  • Open Access
934 Views
19 Pages

CBCT-Derived Volumetric Hard-Tissue Gain After Hydraulic Transcrestal Sinus Floor Elevation with or Without Cross-Linked Hyaluronic Acid: A Non-Randomized Prospective Clinical Study

  • Gaetano Marenzi,
  • Gennaro Ruggiero,
  • Fabrizio Bergaminelli,
  • Alessandra Miniello and ,
  • Alessandro Scarano,
  • Erda Qorri and
  • Roberto Sorrentino
  • + 2 authors+ 0 author

Objectives: The aim of the study was to compare CBCT (Cone Beam Computed Tomography)-derived radiographic hard tissue gain after hydraulic transcrestal sinus floor elevation performed with versus without cross-linked hyaluronic acid (HA) and to asses...

  • Case Report
  • Open Access
900 Views
10 Pages

This report describes a 72-year-old patient for whom a maxillofacial prosthesis was created to treat trismus and jaw deviation after mandibulectomy for osteoradionecrosis following radiotherapy for cancer. The patient’s chief complaints were an...

  • Review
  • Open Access
1,046 Views
20 Pages

Clinical Performance of High-Viscosity Glass Hybrid Restorative Systems in Posterior Teeth: A Scoping Review

  • Antonia Theodora Vrabie,
  • Tinela Panaite,
  • Bogdan Radu Dragomir,
  • Simona Stoleriu and ,
  • Angela Ghiorghe,
  • Irina Nica,
  • Alice Murariu,
  • Sorin Andrian and
  • Gianina Iovan
  • + 4 authors+ 0 author

Background/Objectives: High-viscosity glass hybrid restorative systems (GHRS) were developed to improve the mechanical limitations of conventional glass ionomer cements while preserving their bioactive properties. This scoping review aimed to map and...

(This article belongs to the Special Issue Next-Generation Ceramic and Composite Materials for Prosthodontics and Reconstruction)
  • Article
  • Open Access
740 Views
22 Pages

Superior In Vitro Osteo-Supportive Properties of Trabecular Titanium vs. Chromium–Cobalt Scaffolds

  • Andrea Massimiliano Nebuloni,
  • Roberta Lauro,
  • Michela Maria Taiana,
  • Gaetano Sorano and ,
  • Piero Costa,
  • Enrico Ragni and
  • Laura de Girolamo
  • + 2 authors+ 0 author

Background: Degenerative joint diseases are a major cause of disability and drive the increasing demand for joint arthroplasty. Long-term prosthesis success depends on rapid and stable bone–implant integration, which is influenced by the osteo-...

(This article belongs to the Special Issue Joint Prostheses: Innovations in Shoulder, Hip, and Knee Replacement)
  • Article
  • Open Access
1,041 Views
25 Pages

Background: The Mercer Universal Prosthesis (MUP), designed with a default “neutral” (vertical) socket alignment, was developed to simplify transtibial prosthetic fitting, reduce labor costs, and improve access to prosthetic care in low-r...

(This article belongs to the Section Orthopedics and Rehabilitation)
  • Systematic Review
  • Open Access
1,090 Views
16 Pages

Xenogenic Materials for Alveolar Ridge Preservation: A Systematic Review of Randomized Controlled Trials

  • Ekaterina Diachkova,
  • Marina Skachkova,
  • Diana Sapfirova,
  • Alexandra Kravchenko and ,
  • Mariam Agumava,
  • Maria Kuznetsova,
  • Kira Babieva,
  • Svetlana Tarasenko,
  • Yuriy Vasil’ev and
  • Mikhail Stepanov
  • + 8 authors+ 3 authors

Background/Objectives: Alveolar ridge atrophy following tooth extraction complicates subsequent prosthetic rehabilitation and implant placement. This systematic review seeks to provide a comprehensive evaluation of existing evidence regarding the eff...

(This article belongs to the Special Issue Advanced Biomaterials and 3D-Printed Constructs for Bone Augmentation and Dental Implantology)
  • Article
  • Open Access
1,553 Views
20 Pages

Denture-Related Oral Lesions in Middle-Aged and Older Populations: Clinical Characteristics, Risk Indicators, and Implications in Removable Prosthodontics—A Cross-Sectional Observational Study

  • Teona Anamaria Tudorici,
  • Dragos Ioan Virvescu,
  • Monica Silvia Tatarciuc,
  • Ionut Luchian and ,
  • Gabriel Rotundu,
  • Carina Balcos,
  • Florinel Cosmin Bida,
  • Oana Maria Butnaru,
  • Daniela Argatu and
  • Dana Gabriela Budala
  • + 6 authors+ 1 author

Background/Objectives: This cross-sectional observational study was conducted on 146 patients rehabilitated with removable dentures who attended follow-up examinations. Methods: Sociodemographic, medical, prosthetic, and clinical variables were recor...

(This article belongs to the Special Issue Maintaining Oral Function in Ageing Populations: Evidence-Based Strategies in Removable Prosthodontics)
  • Article
  • Open Access
1,384 Views
45 Pages

Background/Objectives: One of the ongoing clinical constraints is limiting microbial growth on prostheses, justifying the need for material surface enhancements to reduce microbial complications. This study aimed to investigate a potentially applicab...

(This article belongs to the Special Issue Advancements in Prosthetic Dentistry: Materials, Techniques, Ethics, and Sustainable Clinical Applications)
  • Article
  • Open Access
1 Citations
679 Views
21 Pages

Registration Quality and the Limits of Statistical Shape Modeling Evaluation in Transtibial Residual Limb Modeling: A Cross-Sectional Shape Representation Framework

  • Shinichiro Kon,
  • Yukio Agarie,
  • Hironori Suda,
  • Hiroshi Otsuka and ,
  • Kengo Ohnishi,
  • Akihiko Hanahusa,
  • Motoki Takagi and
  • Shinichiro Yamamoto
  • + 3 authors+ 0 author

Background/Objectives: Statistical shape modeling (SSM) is used to describe transtibial residual-limb morphology for prosthetic socket design, simulation, and future structural testing. However, conventional intrinsic metrics such as compactness, gen...

  • Article
  • Open Access
938 Views
11 Pages

Objectives: Limited information is available on how connector size and luting protocols influence the fracture resistance of 3D-printed resin-based fixed dental prostheses (FDPs). This in vitro study evaluated the effect of connector size and luting...

(This article belongs to the Section Prosthodontics)
XFacebookLinkedIn
Prosthesis - ISSN 2673-1592