Skip to Content

13 Results Found

  • Article
  • Open Access
2 Citations
3,815 Views
9 Pages

17 January 2020

Microslit cutting in aluminum foils is considered to be difficult as aluminum foils have low hardness and deformability. In this study, a novel cutting method is proposed where a tungsten microwire is utilized as the tool to cut aluminum foil without...

(This article belongs to the Section Mechanical Engineering)
  • Article
  • Open Access
29 Citations
3,992 Views
18 Pages

Improvement of the Machining Performance of the TW-ECDM Process Using Magnetohydrodynamics (MHD) on Quartz Material

  • Ankit D. Oza,
  • Abhishek Kumar,
  • Vishvesh Badheka,
  • Amit Arora and ,
  • Manoj Kumar,
  • Catalin I. Pruncu and
  • Tej Singh
  • + 2 authors+ 0 author

3 May 2021

Many microslits are typically manufactured on quartz substrates and are used to improve their industrial performance. The fabrication of microslits on quartz is difficult and expensive to achieve using recent traditional machining processes due to it...

(This article belongs to the Special Issue Machinability of Metallic Materials and Composites)
  • Article
  • Open Access
12 Citations
3,982 Views
12 Pages

Laser-Milled Microslits Improve the Bonding Strength of Acrylic Resin to Zirconia Ceramics

  • Saiji Shimoe,
  • Tzu-Yu Peng,
  • Yuki Wakabayashi,
  • Hiroto Takenaka and ,
  • Shogo Iwaguro and
  • Masato Kaku
  • + 1 author+ 0 author

4 April 2020

Heightened aesthetic considerations in modern dentistry have generated increased interest in metal-free “zirconia-supported dentures.” The lifespan of the denture is largely determined by the strength of adhesion between zirconia and the...

(This article belongs to the Special Issue Polymer-Based Materials in Dentistry)
  • Article
  • Open Access
24 Citations
9,208 Views
20 Pages

A Micro-Coordinate Measurement Machine (CMM) for Large-Scale Dimensional Measurement of Micro-Slits

  • So Ito,
  • Hirotaka Kikuchi,
  • Yuanliu Chen,
  • Yuki Shimizu and ,
  • Wei Gao,
  • Kazuhiko Takahashi,
  • Toshihiko Kanayama,
  • Kunmei Arakawa and
  • Atsushi Hayashi
  • + 4 authors+ 0 author

18 May 2016

This paper presents a micro-coordinate measuring machine (micro-CMM) for large-scale dimensional measurement of a micro-slit on a precision die coater by using a shear-mode micro-probe. A glass micro sphere with a nominal diameter of 52.3 μm was atta...

(This article belongs to the Special Issue Design and Applications of Coordinate Measuring Machines)
  • Article
  • Open Access
3 Citations
5,794 Views
11 Pages

Study of Alzheimer’s Disease-Related Biophysical Kinetics with a Microslit-Embedded Cantilever Sensor in a Liquid Environment

  • Myung-Sic Chae,
  • Jinsik Kim,
  • Yong Kyoung Yoo,
  • Jeong Hoon Lee and ,
  • Tae Geun Kim and
  • Kyo Seon Hwang
  • + 1 author+ 0 author

7 August 2017

A microsized slit-embedded cantilever sensor (slit cantilever) was fabricated and evaluated as a biosensing platform in a liquid environment. In order to minimize the degradation caused by viscous damping, a 300 × 100 µm2 (length × width) sized canti...

(This article belongs to the Special Issue Sensors for Health Monitoring and Disease Diagnosis)
  • Article
  • Open Access
7 Citations
3,362 Views
13 Pages

16 July 2020

A Bragg-mirror-assisted terahertz (THz) high-contrast and broadband plasmonic interferometer is proposed and theoretically investigated for potential sensing applications. The central microslit couples the incident THz wave into unidirectional surfac...

(This article belongs to the Section Nanophotonics Materials and Devices)
  • Article
  • Open Access
4 Citations
3,232 Views
14 Pages

26 July 2023

The main objective of this work is to validate an in-line micro-slit rheometer and a micro-extrusion line, both designed for the in-line monitoring and production of filaments for 3D printing using small amounts of material. The micro-filament extrus...

(This article belongs to the Section D: Materials and Processing)
  • Article
  • Open Access
18 Citations
2,798 Views
10 Pages

7 April 2021

Analytical approximations for the acoustical properties of a rigid-porous matrix perforated by labyrinthine slits are developed using classical theories for sound propagation in tortuous slits and for sound absorption by double porosity materials. Pr...

(This article belongs to the Section Mechanical Engineering)
  • Review
  • Open Access
13 Citations
4,358 Views
10 Pages

11 December 2018

Glycosaminoglycans (GAGs) are a class of linear polysaccharides that are ubiquitous in the extracellular matrix (ECM) and on cell surfaces. Due to their key role in development, homeostasis, pathogenesis, and regeneration, GAGs are increasingly used...

(This article belongs to the Special Issue Polyelectrolytes and Polyelectrolyte Complexes-in Memory of Prof. Paul Dubin)
  • Article
  • Open Access
2 Citations
2,251 Views
10 Pages

13 May 2023

With the increasing application of three-dimensional pure aluminum microstructures in micro-electromechanical systems (MEMS) and for fabricating terahertz components, high-quality micro-shaping of pure aluminum has gradually attracted attention. Rece...

(This article belongs to the Special Issue Ultra-Precision Manufacturing Technology)
  • Communication
  • Open Access
3 Citations
2,031 Views
10 Pages

6 December 2024

Tunable perfect acoustic absorption at subwavelength thickness has been a prominent topic in scientific research and engineering applications. Although metamaterials such as labyrinthine metasurfaces and coiling-up-space metamaterials can achieve sub...

(This article belongs to the Special Issue Novel Materials for Sound-Absorbing Applications)
  • Article
  • Open Access
1 Citations
1,916 Views
21 Pages

Verification of Microprobe Calibration Based on Actual Diameter Measurement of the Probe Tip Sphere

  • So Ito,
  • Daichi Inukai,
  • Takehiro Tomioka,
  • Yasutomo Sugisawa and ,
  • Kenta Matsumoto and
  • Kazuhide Kamiya
  • + 1 author+ 0 author

1 December 2025

In three-dimensional measurement using a microprobing system with a micrometric spherical tip, a deviation in the diameter of the probe tip sphere causes measurement errors. In a typical probing system calibration, the effective diameter of the probe...

  • Article
  • Open Access
522 Views
14 Pages

24 August 2026

A high-sensitivity fiber-optic hot-wire anemometer based on a liquid-filled leaky-guided fiber Mach–Zehnder interferometer (LGFMZI) with UV-cured polymer/aluminum-microparticle photothermal encapsulation is proposed and experimentally demonstra...

(This article belongs to the Special Issue Advances in Optical Fibers Sensing and Communication)