8 Results Found

  • Article
  • Open Access
2 Citations
2,832 Views
16 Pages

6 October 2022

Electronically enhanced current transformers (EECT) have gained much interest in power quality assessment. Their magnitude and phase angle error, which mainly relates to the properties of the ferromagnetic materials used, the impedance of the seconda...

(This article belongs to the Topic Power Quality)
  • Article
  • Open Access
16 Citations
10,461 Views
15 Pages

High Frequency Transformer’s Parasitic Capacitance Minimization for Photovoltaic (PV) High-Frequency Link-Based Medium Voltage (MV) Inverter

  • Himanshu,
  • Harsimran Singh,
  • Pandiyan Sathish Kumar,
  • Muhammad Umair Ali and ,
  • Ho Yeong Lee,
  • Muhammad Adil Khan,
  • Gwan Soo Park and
  • Hee-Je Kim
  • + 3 authors+ 0 author

The high-frequency-based medium voltage (MV) inverter is used in renewable energy power sources for power transmission. However, power quality is compromised as a result of the increase in common mode noise currents by the high inter-winding parasiti...

  • Article
  • Open Access
2 Citations
5,038 Views
16 Pages

Investigating the Shielding Effect of Pulse Transformer Operation in Isolated Gate Drivers for SiC MOSFETs

  • Loreine Makki,
  • Marc Anthony Mannah,
  • Christophe Batard,
  • Nicolas Ginot and
  • Julien Weckbrodt

27 June 2021

Wide-bandgap technology evolution compels the advancement of efficient pulse-width gate-driver devices. Integrated enhanced gate-driver planar transformers are a source of electromagnetic disturbances due to inter-winding capacitances, which serve as...

(This article belongs to the Topic Power System Modeling and Control)
  • Article
  • Open Access
11 Citations
12,006 Views
21 Pages

23 May 2019

In isolated power converters, the transformer is a key part of voltage transformation and isolation. Since common-mode (CM) noise is rather difficult to suppress compared with different-mode (DM) noise, more and more scholars are paying attention to...

(This article belongs to the Special Issue Power Transformer Condition Assessment)
  • Article
  • Open Access
1,881 Views
25 Pages

In high-frequency 400 V/48 V matrix planar LLC resonant converters for data center power supplies, enlarged interwinding parasitic capacitance can induce significant transformer-related common-mode (CM) displacement currents. However, the effects of...

  • Article
  • Open Access
18 Citations
4,652 Views
12 Pages

25 May 2018

Frequency Response Analysis (FRA) is an important tool used for diagnostic measurements of power transformers. Standard test configuration applied in the industry is the end-to-end open test setup; however, an interwinding capacitive configuration is...

(This article belongs to the Section F: Electrical Engineering)
  • Feature Paper
  • Article
  • Open Access
2 Citations
3,993 Views
16 Pages

Extended Use for the Frequency Response Analysis: Switching Impulse Voltage Based Preliminary Diagnosis of Potential Sources of Partial Discharges in Transformer

  • Kamalaselvan Arunachalam,
  • Balasubramanian Madanmohan,
  • Rajesh Rajamani,
  • Natarajan Prabaharan and ,
  • Hassan Haes Alhelou and
  • Pierluigi Siano
  • + 1 author+ 0 author

22 November 2020

The Frequency Response Analysis approach (FRA) is useful in the fault diagnosis of transformers. However, its usefulness in diagnosing any potential sources of Partial Discharge (PD) in transformers has not been thoroughly investigated so far. In thi...

(This article belongs to the Section Energy Science and Technology)
  • Article
  • Open Access
7 Citations
2,534 Views
25 Pages

25 November 2024

In electric powertrain traction applications, the adopted trend to improve the performance and efficiency of electromechanical power conversion systems is to increase supply voltages and inverter switching frequencies. As a result, electrical machine...

(This article belongs to the Special Issue Fault Diagnosis for Electrical Machines, Power Electronics, and Drives)