Skip to Content

15 Results Found

  • Article
  • Open Access
21 Citations
5,679 Views
14 Pages

30 November 2018

The dual-bias high-voltage circuit of a transmit amplifier for immersion ultrasound transducer applications is proposed to enhance the therapeutic effect of human HeLa cells. High-voltage output signals generated from a transmit amplifier are typical...

(This article belongs to the Special Issue Ultrasonic Sensors 2018)
  • Article
  • Open Access
10 Citations
5,599 Views
30 Pages

Comparative Study of Coupling Techniques in Lamb Wave Testing of Metallic and Cementitious Plates

  • Santiago Vázquez,
  • Jorge Gosálbez,
  • Ignacio Bosch,
  • Alicia Carrión and ,
  • Carles Gallardo and
  • Jordi Payá
  • + 1 author+ 0 author

20 September 2019

Lamb waves have emerged as a valuable tool to examine long plate-like structures in a faster way compared to conventional bulk wave techniques, which make them attractive in non-destructive testing. However, they present a multimodal and dispersive n...

(This article belongs to the Section Physical Sensors)
  • Article
  • Open Access
7 Citations
4,077 Views
10 Pages

Agar Gel as a Non-Invasive Coupling Medium for Reflectance Photoacoustic (PA) Imaging: Experimental Results on Wall-Painting Mock-Ups

  • Antonina Chaban,
  • George J. Tserevelakis,
  • Evgenia Klironomou,
  • Giannis Zacharakis and
  • Jana Striova

30 August 2022

The new reflectance set-up configuration extended the applicability of the photoacoustic (PA) imaging technique to art objects of any thickness and form. Until now, ultrasound gel or distilled water have been necessary as coupling mediums between the...

(This article belongs to the Special Issue Spectral Imaging for Cultural Heritage)
  • Article
  • Open Access
14 Citations
3,677 Views
21 Pages

2 November 2020

Piezoelectric transducers are triggered by the output voltage signal of a transmit voltage amplifier (TVA). In mobile ultrasound instruments, the sensitivity of piezoelectric transducers is a critical parameter under limited power supply from portabl...

(This article belongs to the Section Physical Sensors)
  • Feature Paper
  • Article
  • Open Access
2 Citations
1,847 Views
17 Pages

19 October 2024

High-performance materials, such as carbon fiber laminates, are costly to manufacture and are often used in demanding environments requiring the use of high-resolution non-destructive testing (NDT) methods to confirm the integrity of the parts. One N...

(This article belongs to the Special Issue Non-Destructive Testing (NDT) of Advanced Composites and Structures)
  • Article
  • Open Access
113 Citations
14,783 Views
10 Pages

12 April 2012

A fiber optic interferometric sensor with an intrinsic transducer along a length of the fiber is presented for ultrasound measurements of the acoustic emission from partial discharges inside oil-filled power apparatus. The sensor is designed for high...

(This article belongs to the Special Issue Optical Fiber Sensors 2012)
  • Article
  • Open Access
9 Citations
4,382 Views
15 Pages

Wafer-Bonding Fabricated CMUT Device with Parylene Coating

  • Changde He,
  • Binzhen Zhang,
  • Chenyang Xue,
  • Wendong Zhang and
  • Shengdong Zhang

The advantages of the capacitive micromachined ultrasound transducer (CMUT) technology have provided revolutionary advances in ultrasound imaging. Extensive research on CMUT devices for high-frequency medical imaging applications has been conducted b...

(This article belongs to the Section E: Engineering and Technology)
  • Article
  • Open Access
928 Views
20 Pages

1 March 2026

Capacitive micromachined ultrasonic transducers (CMUTs) are a promising alternative to conventional piezoelectric transducers, offering superior design flexibility and broadband operational characteristics. However, their clinical and practical deplo...

(This article belongs to the Special Issue Electronic Test and Measurement Instrumentation: Design and Applications (2nd Edition))
  • Article
  • Open Access
449 Views
14 Pages

Design, Simulation, and Experimental Validation of an Optimized Bi-Fresnel Zone Plate Acoustic Lens

  • Daniel Tarrazó-Serrano,
  • Sergio Castiñeira-Ibáñez,
  • Lucas Onrubia-Fontangordo,
  • Constanza Rubio and
  • Antonio Uris

19 August 2026

Acoustic lenses based on Fresnel Zone Plates provide an efficient and low-cost approach for ultrasound focusing, with potential applications in Focused Ultrasound, High-Intensity Focused Ultrasound, and blood–brain barrier opening. This work pr...

(This article belongs to the Special Issue Applications of Ultrasonic Technology in Biomedical Sciences, 2nd Edition)
  • Article
  • Open Access
2 Citations
4,205 Views
24 Pages

7 March 2019

Parameters to measure nonlinearity in polymethylmethacrylate (PMMA) and carbon fiber reinforced polymer (CFRP) materials have been determined with nonlinear ultrasound (NLUS). The nonlinear parameter β has been determined using the variati...

(This article belongs to the Special Issue Ultrasonic Sensors 2018)
  • Article
  • Open Access
20 Citations
5,499 Views
15 Pages

Deep-Subwavelength-Optimized Holey-Structured Metamaterial Lens for Nonlinear Air-Coupled Ultrasonic Imaging

  • Marco Boccaccio,
  • Pasquale Rachiglia,
  • Gian Piero Malfense Fierro,
  • Giovanni Pio Pucillo and
  • Michele Meo

7 February 2021

Ultrasound non-destructive testing (NDT) is a common technique used for defect detection in different materials, from aluminium to carbon-fiber-reinforced polymers (CFRPs). In most cases, a liquid coupling medium/immersion of the inspected component...

(This article belongs to the Section Intelligent Sensors)
  • Article
  • Open Access
59 Citations
11,288 Views
22 Pages

Air-Coupled, Contact, and Immersion Ultrasonic Non-Destructive Testing: Comparison for Bonding Quality Evaluation

  • Bengisu Yilmaz,
  • Aadhik Asokkumar,
  • Elena Jasiūnienė and
  • Rymantas Jonas Kažys

27 September 2020

The objective of this study is to compare the performance of different ultrasonic non-destructive testing (NDT) techniques for bonding quality evaluation. Aluminium-epoxy-aluminium single lap joints containing debonding in the form of release film in...

(This article belongs to the Special Issue Advances in Nondestructive Testing and Structural Health Monitoring for Materials and Aerospace Industry Applications)
  • Article
  • Open Access
1 Citations
2,411 Views
17 Pages

Unique Characteristics of Pulse-Echo Sensing Systems for Ultrasonic Immersion Testing in Harsh Environments

  • Gaofeng Sha,
  • Andrew R. Bozek,
  • Bernhard R. Tittmann and
  • Cliff J. Lissenden

4 December 2024

Ultrasound is an excellent way to acquire data that reveal useful information about systems operating in harsh environments, which may include elevated temperature, ionizing radiation, and aggressive chemicals. The effects of harsh environments on pi...

(This article belongs to the Special Issue Smart Sensors for Structural Health Monitoring and Nondestructive Evaluation: 2nd Edition)
  • Article
  • Open Access
5 Citations
6,393 Views
11 Pages

High Accuracy Ultrasound Micro-Distance Measurements with PMUTs under Liquid Operation

  • Iván Zamora,
  • Eyglis Ledesma,
  • Arantxa Uranga and
  • Núria Barniol

1 July 2021

Ultrasonic systems driven by multi-frequency continuous waves (MFCW) have been used for range distance measurement, offering high accuracy in long and medium range distance estimation. However, the use of continuous waves in very short-distance measu...

(This article belongs to the Special Issue Piezoelectric Micromachined Ultrasound Transducer (PMUT) Devices: Sensing, Actuation Communication and Imaging in the µ-Scale)
  • Article
  • Open Access
2 Citations
4,325 Views
15 Pages

Low-Intensity Pulsed Ultrasound Effect on MIO-M1 Cell Viability: Setup Validation and Standing Waves Analysis

  • Irais Poblete-Naredo,
  • Mario Ibrahin Gutierrez,
  • Diana Estela Mendoza-Sánchez,
  • Arturo Ortega and ,
  • Arnulfo Albores,
  • Josefina Gutiérrez-Martínez,
  • Lorenzo Leija and
  • Arturo Vera
  • + 3 authors+ 0 author

30 December 2020

Low-intensity pulsed ultrasound (LIPUS) has been proposed for novel therapies still under study, where similar parameters and protocols have been used for producing opposite effects that range from increasing cell viability to provoking cell death. T...

(This article belongs to the Special Issue Modelling, Simulation and Data Analysis in Acoustical Problems Ⅱ)