Skip to Content

10 Results Found

  • Article
  • Open Access
4 Citations
2,201 Views
13 Pages

Use of Double-Layer Carotid Stents Is Associated with Improved Patient Survival and Lower Neurological Complications: A Single-Center Retrospective Observational Study

  • Kipras Mikelis,
  • Marius Kurminas,
  • Givi Lengvenis,
  • Radvilas Jančiauskas and ,
  • Nerijus Misonis,
  • Povilas Budrys,
  • Rokas Šerpytis and
  • Andrius Berūkštis
  • + 3 authors+ 0 author

29 January 2025

Background/Objectives: Dual-layer stents (DLS) with micromesh technology may offer better protection from plaque protrusion compared to single-layer stents (SLS), but little data are available. The aim of this study is to compare clinical outcomes of...

(This article belongs to the Special Issue Cerebrovascular Disease: Symptoms, Diagnosis and Current Treatment)
  • Article
  • Open Access
1,140 Views
5 Pages

Comparison of Different Carotid Stent Designs in Endovascular Therapy of Severe Carotid Artery Stenosis

  • Philipp Gruber,
  • Jatta Berberat,
  • Timo Kahles,
  • Javier Anon and ,
  • Michael Diepers,
  • Krassen Nedeltchev and
  • Luca Remonda
  • + 2 authors+ 0 author

Background: One of the major periprocedural risks of carotid artery stenting is embolism caused either by plaque debris or by local thrombus forming. Double-layer micromesh stent design has shown to lower the chance of debris embolism but might have...

  • Article
  • Open Access
2 Citations
1,404 Views
18 Pages

Background: Autologous arteriovenous fistula (AVF) is the most commonly used vascular access for end-stage renal disease patients. However, during the maturation process following AVF surgery, insufficient initial venous diameter often results in ina...

(This article belongs to the Special Issue Metals and Alloys for Biomedical Applications (2nd Edition))
  • Article
  • Open Access
17 Citations
4,281 Views
27 Pages

Drug-eluting stents have been widely implanted to prevent neointimal hyperplasia associated with bare metal stents. Conventional polymers and anti-proliferative drugs suffer from stent thrombosis due to the non-selective nature of the drugs and hyper...

(This article belongs to the Special Issue Future Trends in Biomaterials and Devices for Cells and Tissues)
  • Article
  • Open Access
17 Citations
9,894 Views
12 Pages

In this study, a porous oxide layer was formed on the surface of 316L stainless steel (SS) by combining Ti magnetron sputtering and plasma electrolytic oxidation (PEO) with the aim to produce a polymer-free drug carrier for drug eluting stent (DES) a...

(This article belongs to the Special Issue Coating Deposition and Surface Functionalization of Implants for Biomedical Applications)
  • Article
  • Open Access
7 Citations
2,793 Views
10 Pages

Effectiveness of a Novel Covered Stent without External Thread Fixation for Anastomotic Leakage after Total or Proximal Gastrectomy for Gastric Cancer

  • Young-Il Kim,
  • Chan Gyoo Kim,
  • Jong Yeul Lee,
  • Il Ju Choi and ,
  • Bang Wool Eom,
  • Hong Man Yoon,
  • Keun Won Ryu and
  • Young-Woo Kim
  • + 3 authors+ 0 author

23 July 2021

A thread-fix stent entails long hospitalization and patient discomfort. We aimed to evaluate the efficacy of a novel stent with silicone-covered outer double layers without external fixation (Beta stent) for anastomotic leakage after total or proxima...

(This article belongs to the Special Issue New Technologies and Advancements in Gastro-Esophageal Cancer Surgery)
  • Article
  • Open Access
5 Citations
8,670 Views
13 Pages

Use of Micropatterned Thin Film Nitinol in Carotid Stents to Augment Embolic Protection

  • Mahdis Shayan,
  • Brian T. Jankowitz,
  • Puneeth Shridhar and
  • Youngjae Chun

Stenting is an alternative to endarterectomy for the treatment of carotid artery stenosis. However, stenting is associated with a higher risk of procedural stroke secondary to distal thromboembolism. Hybrid stents with a micromesh layer have been pro...

  • Article
  • Open Access
14 Citations
6,685 Views
11 Pages

Real-Time Electrical Bioimpedance Characterization of Neointimal Tissue for Stent Applications

  • David Rivas-Marchena,
  • Alberto Olmo,
  • José A. Miguel,
  • Mar Martínez and ,
  • Gloria Huertas and
  • Alberto Yúfera
  • + 1 author+ 0 author

28 July 2017

To follow up the restenosis in arteries stented during an angioplasty is an important current clinical problem. A new approach to monitor the growth of neointimal tissue inside the stent is proposed on the basis of electrical impedance spectroscopy (...

(This article belongs to the Section Biosensors)
  • Article
  • Open Access
4 Citations
2,667 Views
13 Pages

26 July 2022

Drug-eluting stents (DES) have become the main method of interventional therapy for coronary heart disease, because their drug coating can effectively reduce the incidence of restenosis after stent implantation. Biodegradable polymers for coatings ar...

(This article belongs to the Section Biobased and Biodegradable Polymers)
  • Case Report
  • Open Access
720 Views
11 Pages

Functional Ureteral Obstruction Due to Retroperitoneal Tissue Interposition During Oblique Lumbar Interbody Fusion: A Report of Two Cases

  • Jun-Seok Lee,
  • Young-Hoon Kim,
  • Sang-Il Kim,
  • Kihyun Kwon and ,
  • Sangjun Park,
  • Joonghyun Ahn,
  • Chungwon Bang and
  • Hyung-Youl Park
  • + 3 authors+ 0 author

23 April 2026

Background/Objectives: Ureteral complications following oblique lumbar interbody fusion (OLIF) are uncommon and are typically attributed to direct mechanical injury. Functional ureteral obstruction without overt ureteral damage remains poorly charact...

(This article belongs to the Special Issue Clinical Research on Minimally Invasive Spine Surgery)