Skip to Content
You are currently on the new version of our website. Access the old version .

7 Results Found

  • Article
  • Open Access
29 Citations
6,448 Views
19 Pages

18 November 2017

This paper proposes the use of bridge type fault current limiters (BFCLs) as a potential solution to reduce the impact of fault disturbance on voltage source converter-based high voltage DC (VSC-HVDC) systems. Since VSC-HVDC systems are vulnerable to...

(This article belongs to the Section F: Electrical Engineering)
  • Article
  • Open Access
38 Citations
4,448 Views
23 Pages

26 February 2019

This paper proposes a non-superconducting bridge-type fault current limiter (BFCL) as a potential solution to the fault problems of doubly fed induction generator (DFIG) integrated voltage source converter high-voltage DC (VSC-HVDC) transmission syst...

(This article belongs to the Special Issue Advances in Renewable Energy Technologies for Sustainability)
  • Article
  • Open Access
11 Citations
3,446 Views
16 Pages

Non-Linear Control for Variable Resistive Bridge Type Fault Current Limiter in AC-DC Systems

  • Md Shafiul Alam,
  • Mohammad Ali Yousef Abido and
  • Alaa El-Din Hussein

22 February 2019

This paper proposes a non-linear control-based variable resistive bridge type fault current limiter (VR-BFCL) as a prospective solution to ease the effect of disturbances on voltage source converter-based high voltage DC (VSC-HVDC) systems. A non-lin...

(This article belongs to the Section F: Electrical Engineering)
  • Article
  • Open Access
20 Citations
5,296 Views
26 Pages

Design of Robust Fuzzy Logic Controller Based on the Levenberg Marquardt Algorithm and Fault Ride Trough Strategies for a Grid-Connected PV System

  • Saif Ul Islam,
  • Kamran Zeb,
  • Waqar Ud Din,
  • Imran Khan and ,
  • Muhammad Ishfaq,
  • Altaf Hussain,
  • Tiago Davi Curi Busarello and
  • Hee Je Kim
  • + 3 authors+ 0 author

This paper emphasizes the design and investigation of a new optimization scheme for a grid-connected photovoltaic system (PVS) under unbalance faults. The proposed scheme includes fuzzy logic controller (FLC) based on the Levenberg–Marquardt (L...

(This article belongs to the Special Issue Grid Connected Photovoltaic Systems)
  • Article
  • Open Access
28 Citations
5,096 Views
25 Pages

Fault Ride Through Capability Improvement of DFIG Based Wind Farm Using Nonlinear Controller Based Bridge-Type Flux Coupling Non-Superconducting Fault Current Limiter

  • Md. Rashidul Islam,
  • Md. Najmul Huda,
  • Jakir Hasan,
  • Mohammad Ashraf Hossain Sadi and ,
  • Ahmed AbuHussein,
  • Tushar Kanti Roy and
  • Md. Apel Mahmud
  • + 2 authors+ 0 author

3 April 2020

High penetration of Doubly Fed Induction Generator (DFIG) into existing power grid can attribute complex issues as they are very sensitive to the grid faults. In addition, Fault Ride Through (FRT) is one of the main requirements of the grid code for...

  • Article
  • Open Access
11 Citations
3,580 Views
19 Pages

Design and Implementation of Novel Fault Ride through Circuitry and Control for Grid-Connected PV System

  • Donghwi Kim,
  • Umar Fitra Ramadhan,
  • Saif Ul Islam,
  • Seungmin Jung and
  • Minhan Yoon

8 August 2022

This paper provides a comparison of a designed method of a fault ride through (FRT) circuit, i.e., switch-type fault current limiter (STFCL) and bridge-type fault current limiter (BFCL), to optimize the electrical parameters of grid-connected solar s...

(This article belongs to the Special Issue Renewable Energy: Technologies and Challenges)
  • Article
  • Open Access
11 Citations
3,754 Views
25 Pages

30 June 2022

The technology of variable speed wind turbines is very promising in renewable power generation. It is imperative for wind turbines to gain control after grid disturbances and contribute to the stability of power grids as part of the requirements of g...

(This article belongs to the Section A: Sustainable Energy)