Skip to Content

13 Results Found

  • Article
  • Open Access
4 Citations
4,268 Views
22 Pages

21 May 2025

Natural Gas Liquid (NGL) pumps are critical assets in oil and gas operations, where unplanned failures can result in substantial production losses. Traditional maintenance approaches, often based on static schedules and expert judgement, are inadequa...

(This article belongs to the Special Issue Application of Artificial Intelligence in Industrial Process Modelling and Optimization)
  • Article
  • Open Access
6 Citations
2,235 Views
18 Pages

29 March 2024

The investigation of the reliability of long-life equipment is typically hindered by the lack of experimental data, which makes accurate assessments challenging. To address this problem, a bootstrap method based on the improved RBF (radial basis func...

(This article belongs to the Special Issue Advances and Challenges in Reliability and Maintenance Engineering)
  • Article
  • Open Access
10 Citations
3,802 Views
17 Pages

Reliability Prediction and FMEA of Loading and Unloading Truss Robot for CNC Punch

  • Kaiyue Zhang,
  • Zhixin Jia,
  • Renpeng Bian,
  • Ketai He and
  • Zhicheng Jia

14 April 2023

Loading and unloading truss robot for computer numerical control (CNC) punch is widely used in the production of sheet metal parts, as its reliability level is directly related to the quality of sheet metal parts. Especially for the automatic sheet m...

(This article belongs to the Special Issue Machine Automation: System Design, Analysis and Control)
  • Article
  • Open Access
608 Views
38 Pages

Mission-Profile-Aware Physics-of-Failure Reliability Assessment and Quantitative FMEA of a 10 kW Solid-State Transformer

  • Mihirkumar Patel,
  • Olga Lavrova,
  • Manaswini Gangineni,
  • Tyler Bowman and ,
  • Alvaro Cardoza,
  • Timothy Donnelly and
  • Lee Rashkin
  • + 2 authors+ 0 author

23 September 2026

Solid-state transformers (SSTs) are pivotal for next-generation power systems, yet their widespread adoption is hindered by reliability uncertainties under diverse operational conditions. This paper introduces a mission-profile-aware, physics-of-fail...

(This article belongs to the Section F3: Power Electronics)
  • Article
  • Open Access
1,555 Views
29 Pages

25 December 2025

Designing cost-effective, reliable diagnostic sensor suites for complex assets remains challenging due to conflicting objectives across stakeholders. A holistic framework that integrates the Normalised Diagnostic Contribution Index (NDCI)—which...

(This article belongs to the Special Issue Sensor Data-Driven Fault Diagnosis Techniques)
  • Article
  • Open Access
10 Citations
6,616 Views
11 Pages

A Statistical State Analysis of a Marine Gas Turbine

  • Suzana Lampreia,
  • Valter Vairinhos,
  • Victor Lobo and
  • José Requeijo

8 July 2019

This paper describes the analysis, from a statistical point of view, of a maritime gas turbine, under various operating conditions, so as to determine its state. The data used concerns several functioning parameters of the turbines, such as temperatu...

  • Article
  • Open Access
293 Views
19 Pages

24 September 2026

Power transformers are critical, capital-intensive assets in electricity distribution networks, and their failure disrupts supply while incurring substantial repair costs. Building on an earlier probabilistic analysis of power transformers with six f...

  • Article
  • Open Access
323 Views
25 Pages

Reliability Assessment of EMU Onboard Power Supply Boards Based on Output Ripple Degradation and a Nonlinear Wiener Process

  • Haijing Hou,
  • Jiaqi Zhang,
  • Qiyu An,
  • Hua Zhang and ,
  • Qi Dong and
  • Bo Liu
  • + 1 author+ 0 author

Reliability assessment of EMU onboard power supply boards is constrained by scarce field failure data and the intrusive nature of component-level degradation monitoring. Moreover, conventional linear degradation models may inadequately characterize t...

(This article belongs to the Special Issue Advanced Stability and Reliability Technologies for Power Electronic Systems)
  • Feature Paper
  • Article
  • Open Access
442 Views
33 Pages

A Five-State Functional Model of Electric Vehicle Charging Infrastructure with Reinterpreted MTTF, MTTR, and MTBF Indicators

  • Marek Woźniak,
  • Stanisław Duer,
  • Jacek Paś,
  • Dariusz Bernatowicz and
  • Beata Kulawińska

27 August 2026

This study presents a five-state functional model for assessing the reliability of electric vehicle charging infrastructure from the perspective of charging-service capability. The model distinguishes full functionality, three levels of degradation,...

  • Article
  • Open Access
6 Citations
2,783 Views
21 Pages

Clamped-single submodule (CSSM) has DC short circuit current protection function to improve the safety and stability of high voltage, direct current (HVDC) system. In order to carry out the protection, it needs an additional number of insulated gate...

(This article belongs to the Section Power Electronics)
  • Feature Paper
  • Review
  • Open Access
39 Citations
12,448 Views
59 Pages

A Critical Review on the Battery System Reliability of Drone Systems

  • Tianren Zhao,
  • Yanhui Zhang,
  • Minghao Wang,
  • Wei Feng and ,
  • Shengxian Cao and
  • Gong Wang
  • + 1 author+ 0 author

31 July 2025

The reliability of unmanned aerial vehicle (UAV) energy storage battery systems is critical for ensuring their safe operation and efficient mission execution, and has the potential to significantly advance applications in logistics, monitoring, and e...

  • Article
  • Open Access
7 Citations
2,919 Views
24 Pages

20 November 2024

In today’s competitive industrial landscape, Reliability Engineering plays a vital role in minimizing costs and expenses in energy projects. The main focus of this paper is to propose the integration of a fuzzy-based FMECA process into a RAM an...

(This article belongs to the Special Issue Advances and Challenges in Reliability and Maintenance Engineering)
  • Article
  • Open Access
898 Views
29 Pages

16 October 2026

Excessive vibrations in rotating machinery accelerate wear and component failures, causing undesired downtime in industrial plants. To assess the severity of these vibration levels, ISO 10816-7 classifies pump condition into four zones. Zone A repres...

(This article belongs to the Special Issue Mechanical Systems Condition Monitoring and Fault Diagnosis)