You are currently viewing a new version of our website. To view the old version click .

23 Results Found

  • Article
  • Open Access
22 Citations
4,905 Views
22 Pages

19 January 2021

With the increasing penetration level of wind turbine generators (WTGs) integrated into the power system, the WTGs are enforced to aid network and fulfill the low voltage ride through (LVRT) requirements during faults. To enhance LVRT capability of p...

  • Article
  • Open Access
5 Citations
2,687 Views
20 Pages

27 September 2022

This article demonstrates a new topology for optimization of the electrical variables and enhancement of low-voltage-ride-through (LVRT) capacity of a grid-tied photovoltaic system (PS) during asymmetrical faults. The proposed topology comprises a fu...

  • Article
  • Open Access
2 Citations
2,112 Views
25 Pages

19 May 2023

In accordance with South Korea’s recent 2030 Carbon Neutral Plan, an 8GW offshore wind farm is planned for construction in the South-west Sea. Therefore, it is expected that large-scale wind turbines will be installed, and these turbines must o...

  • Article
  • Open Access
13 Citations
3,970 Views
16 Pages

5 May 2018

The stator side of a double-fed induction generator (DFIG) is directly connected to the grid, so the DFIG is sensitive to a voltage drop caused by power system faults. A double resistors braking method based on fuzzy control is proposed to improve th...

  • Article
  • Open Access
5 Citations
2,534 Views
16 Pages

Fault Calculation Method of Distribution Network Based on Deep Learning

  • Cong Zhang,
  • Ke Peng,
  • Huan Li,
  • Bingyin Xu and
  • Yu Chen

18 June 2021

Under the low voltage ride through (LVRT) control strategy, the inverter interfaced distributed generation (IIDG) needs to change the output mode of the inverter according to the voltage of the connected nodes. The short-circuit current is related to...

  • Article
  • Open Access
19 Citations
5,514 Views
20 Pages

Comprehensive Reactive Power Support of DFIG Adapted to Different Depth of Voltage Sags

  • Yangwu Shen,
  • Mingjian Cui,
  • Qin Wang,
  • Feifan Shen,
  • Bin Zhang and
  • Liqing Liang

14 June 2017

The low voltage ride-through (LVRT) capability of the doubly-fed induction generator (DFIG) significantly impacts upon the integration of wind power into the power grid. This paper develops a novel comprehensive control strategy to enhance the LVRT a...

  • Article
  • Open Access
9 Citations
5,487 Views
15 Pages

5 October 2017

Abstract: To increase the utilization of wind power in the power system, grid integration standards have been proposed for the stable integration of large-scale wind power plants. In particular, fault-ride-through capability, especially Low-Voltage-R...

  • Article
  • Open Access
17 Citations
3,899 Views
19 Pages

16 December 2019

This paper presents a control scheme for a photovoltaic (PV) system that uses a single-phase grid-connected inverter with low-voltage ride-through (LVRT) capability. In this scheme, two PI regulators are used to adjust the power angle and voltage mod...

  • Article
  • Open Access
7 Citations
3,397 Views
12 Pages

Modular Multilevel Converter for Low-Voltage Ride-Through Support in AC Networks

  • Victor Ramon França Bezerra de Souza,
  • Luciano Sales Barros and
  • Flavio Bezerra Costa

27 August 2021

New grid-connected systems have imposed additional requirements regarding reliability, power quality, high levels of power processing capacity, and fault support, where power converters have a crucial role in fulfilling these requirements. Overcoming...

  • Article
  • Open Access
12 Citations
4,527 Views
20 Pages

14 July 2017

Fast control DC-link voltage is the key to enhance Low-Voltage Ride-Through (LVRT) for the Permanent Magnet Synchronous Generator (PMSG). When grid voltage dips deeply, by the constraint of the capacity of the grid-side converter and reactive power s...

  • Article
  • Open Access
178 Views
31 Pages

19 December 2025

With the rapid development of new energy, high-proportion new energy power systems have significantly reduced inertia and voltage support capacity, facing severe stability challenges. Virtual Synchronous Generator (VSG) control, which simulates the i...

  • Article
  • Open Access
7 Citations
1,509 Views
22 Pages

4 September 2024

The doubly-fed induction generator (DFIG) is vulnerable to overcurrent at the stator winding and overvoltage at the DC link due to voltage drop after the grid fault. The large wind farm may have a capacity of several million MWs, whose tripping yield...

  • Article
  • Open Access
20 Citations
4,134 Views
21 Pages

20 January 2019

With the substantial increase in the capacity of grid-connected photovoltaic (PV) power, the adverse effects of its complex fault characteristics on grid relay protection are increasingly highlighted. Based on the introduction of the topology and the...

  • Article
  • Open Access
234 Views
17 Pages

16 December 2025

Recently, the installed generation capacity of wind energy has expanded significantly, and the doubly fed induction generator (DFIG) has gained a prominent position amongst wind generators owing to its superior performance. It is extremely vital to e...

  • Article
  • Open Access
4 Citations
2,879 Views
22 Pages

10 February 2025

Grid-forming (GFM) converters face significant challenges in low-voltage ride-through (LVRT) due to their limited overcurrent capacity. Various transient current-limiting methods have been proposed to address this issue. However, simple current-limit...

  • Article
  • Open Access
1 Citations
1,895 Views
20 Pages

In order to enhance the transient stability of offshore wind turbines (OWTs) in marine energy systems, the grid codes stipulate that OWTs should possess the low-voltage ride-through (LVRT) ability of being grid-tied and injecting reactive current dur...

  • Article
  • Open Access
15 Citations
3,929 Views
19 Pages

Enhanced TVI for Grid Forming VSC under Unbalanced Faults

  • Markel Zubiaga,
  • Carmen Cardozo,
  • Thibault Prevost,
  • Alain Sanchez-Ruiz,
  • Eneko Olea,
  • Pedro Izurza,
  • Siam Hasan Khan and
  • Joseba Arza

27 September 2021

With an increasing capacity of inverter-based generation and with a 100% renewable energy power system on the horizon, grid forming converters have the potential to become the prevalent control mode in the grid. Thus, the correct performance of these...

  • Article
  • Open Access
5 Citations
3,229 Views
17 Pages

28 April 2020

This study introduces a coordinated low-voltage ride through (LVRT) control method for permanent magnet synchronous generator (PMSG) wind turbines (WT) interconnected with an energy storage system (ESS). In the proposed method, both the WT pitch and...

  • Article
  • Open Access
2 Citations
2,591 Views
14 Pages

Strategies to Increase the Transient Active Power of Photovoltaic Units during Low Voltage Ride Through

  • Xiangwu Yan,
  • Baixue Liang,
  • Jiaoxin Jia,
  • Waseem Aslam,
  • Chenguang Wang,
  • Shizheng Zhang and
  • Hongbin Ma

24 August 2021

Due to a limitation in the magnitude of the three-phase output inverter currents, the output active power of the photovoltaic (PV) unit has been de-rated during low voltage ride through, which brings great instability risk to the power system. With t...

  • Article
  • Open Access
625 Views
22 Pages

22 September 2025

As offshore wind farms continue to scale up in both distance and capacity, the design of transmission systems has become a critical factor in the effective development and utilization of offshore wind energy. In response to the growing trend of large...

  • Article
  • Open Access
25 Citations
7,579 Views
22 Pages

9 September 2013

This paper aims to explore a viable solution for a doubly-fed induction generator (DFIG)-based wind farm to meet the reactive support requirement of the low voltage ride-through (LVRT) grid code with safe grid-connected operation during asymmetrical...

  • Article
  • Open Access
6 Citations
1,508 Views
18 Pages

Application and Comparison of a Modified Protection Scheme Utilizing a Proportional–Integral Controller with a Conventional Design to Enhance Doubly Fed Induction Generator Wind Farm Operations during a Balanced Voltage Dip

  • Azeddine Loulijat,
  • Hamid Chojaa,
  • Mouncef El Marghichi,
  • Naoufl Ettalabi,
  • Abdelilah Hilali,
  • Abdulwasa B. Barnawi,
  • Z. M. S. Elbarbary and
  • Mahmoud A. Mossa

26 September 2023

The doubly fed induction generator (DFIG) is vulnerable to grid faults due to its direct stator connection, causing issues like excess stator current during voltage dips. Consequently, sensitive inverters suffer from increased currents, and the DC-li...

  • Article
  • Open Access
7 Citations
4,405 Views
29 Pages

Design Enhancement of Grid-Connected Residential PV Systems to Meet the Saudi Electricity Regulations

  • Faris E. Alfaris,
  • Essam A. Al-Ammar,
  • Ghazi A. Ghazi and
  • Ahmed A. Al-Katheri

20 June 2024

Distributed grid-connected photovoltaic (PV) generation explores several methods that produce energy at or near the point of consumption, with the aim of reducing electricity losses among transmission networks. Consequently, home on-grid PV applicati...